hub/pv_assessment/pv_system_assessment_without_consumption.py

214 lines
12 KiB
Python
Raw Normal View History

import math
import csv
import hub.helpers.constants as cte
from pv_assessment.electricity_demand_calculator import HourlyElectricityDemand
from hub.catalog_factories.energy_systems_catalog_factory import EnergySystemsCatalogFactory
from hub.helpers.monthly_values import MonthlyValues
class PvSystemProduction:
def __init__(self, building=None, pv_system=None, battery=None, tilt_angle=None,
solar_angles=None, pv_installation_type=None, simulation_model_type=None, module_model_name=None,
inverter_efficiency=None, system_catalogue_handler=None, roof_percentage_coverage=None,
facade_coverage_percentage=None, csv_output=False, output_path=None):
"""
:param building:
:param tilt_angle:
:param solar_angles:
:param simulation_model_type:
:param module_model_name:
:param inverter_efficiency:
:param system_catalogue_handler:
:param roof_percentage_coverage:
:param facade_coverage_percentage:
"""
self.building = building
self.tilt_angle = tilt_angle
self.solar_angles = solar_angles
self.pv_installation_type = pv_installation_type
self.simulation_model_type = simulation_model_type
self.module_model_name = module_model_name
self.inverter_efficiency = inverter_efficiency
self.system_catalogue_handler = system_catalogue_handler
self.roof_percentage_coverage = roof_percentage_coverage
self.facade_coverage_percentage = facade_coverage_percentage
self.pv_hourly_generation = None
self.t_cell = None
self.results = {}
self.csv_output = csv_output
self.output_path = output_path
if pv_system is not None:
self.pv_system = pv_system
else:
for energy_system in self.building.energy_systems:
for generation_system in energy_system.generation_systems:
if generation_system.system_type == cte.PHOTOVOLTAIC:
self.pv_system = generation_system
if battery is not None:
self.battery = battery
else:
for energy_system in self.building.energy_systems:
for generation_system in energy_system.generation_systems:
if generation_system.system_type == cte.PHOTOVOLTAIC and generation_system.energy_storage_systems is not None:
for storage_system in generation_system.energy_storage_systems:
if storage_system.type_energy_stored == cte.ELECTRICAL:
self.battery = storage_system
@staticmethod
def explicit_model(pv_system, inverter_efficiency, number_of_panels, irradiance, outdoor_temperature):
inverter_efficiency = inverter_efficiency
stc_power = float(pv_system.standard_test_condition_maximum_power)
stc_irradiance = float(pv_system.standard_test_condition_radiation)
cell_temperature_coefficient = float(pv_system.cell_temperature_coefficient) / 100 if (
pv_system.cell_temperature_coefficient is not None) else None
stc_t_cell = float(pv_system.standard_test_condition_cell_temperature)
nominal_condition_irradiance = float(pv_system.nominal_radiation)
nominal_condition_cell_temperature = float(pv_system.nominal_cell_temperature)
nominal_t_out = float(pv_system.nominal_ambient_temperature)
g_i = irradiance
t_out = outdoor_temperature
t_cell = []
pv_output = []
for i in range(len(g_i)):
t_cell.append((t_out[i] + (g_i[i] / nominal_condition_irradiance) *
(nominal_condition_cell_temperature - nominal_t_out)))
pv_output.append((inverter_efficiency * number_of_panels * (stc_power * (g_i[i] / stc_irradiance) *
(1 - cell_temperature_coefficient *
(t_cell[i] - stc_t_cell)))))
return pv_output
def rooftop_sizing(self, roof):
pv_system = self.pv_system
if self.module_model_name is not None:
self.system_assignation()
# System Sizing
module_width = float(pv_system.width)
module_height = float(pv_system.height)
roof_area = roof.perimeter_area
pv_module_area = module_width * module_height
available_roof = (self.roof_percentage_coverage * roof_area)
# Inter-Row Spacing
winter_solstice = self.solar_angles[(self.solar_angles['AST'].dt.month == 12) &
(self.solar_angles['AST'].dt.day == 21) &
(self.solar_angles['AST'].dt.hour == 12)]
solar_altitude = winter_solstice['solar altitude'].values[0]
solar_azimuth = winter_solstice['solar azimuth'].values[0]
distance = ((module_height * math.sin(math.radians(self.tilt_angle)) * abs(
math.cos(math.radians(solar_azimuth)))) / math.tan(math.radians(solar_altitude)))
distance = float(format(distance, '.2f'))
# Calculation of the number of panels
space_dimension = math.sqrt(available_roof)
space_dimension = float(format(space_dimension, '.2f'))
panels_per_row = math.ceil(space_dimension / module_width)
number_of_rows = math.ceil(space_dimension / distance)
total_number_of_panels = panels_per_row * number_of_rows
total_pv_area = total_number_of_panels * pv_module_area
roof.installed_solar_collector_area = total_pv_area
return panels_per_row, number_of_rows
def system_assignation(self):
generation_units_catalogue = EnergySystemsCatalogFactory(self.system_catalogue_handler).catalog
catalog_pv_generation_equipments = [component for component in
generation_units_catalogue.entries('generation_equipments') if
component.system_type == 'photovoltaic']
selected_pv_module = None
for pv_module in catalog_pv_generation_equipments:
if self.module_model_name == pv_module.model_name:
selected_pv_module = pv_module
if selected_pv_module is None:
raise ValueError("No PV module with the provided model name exists in the catalogue")
for energy_system in self.building.energy_systems:
for idx, generation_system in enumerate(energy_system.generation_systems):
if generation_system.system_type == cte.PHOTOVOLTAIC:
new_system = selected_pv_module
# Preserve attributes that exist in the original but not in the new system
for attr in dir(generation_system):
# Skip private attributes and methods
if not attr.startswith('__') and not callable(getattr(generation_system, attr)):
if not hasattr(new_system, attr):
setattr(new_system, attr, getattr(generation_system, attr))
# Replace the old generation system with the new one
energy_system.generation_systems[idx] = new_system
def grid_tied_system(self):
rooftops_pv_output = [0] * 8760
facades_pv_output = [0] * 8760
rooftop_number_of_panels = 0
if 'rooftop' in self.pv_installation_type.lower():
for roof in self.building.roofs:
if roof.perimeter_area > 40:
np, ns = self.rooftop_sizing(roof)
single_roof_number_of_panels = np * ns
rooftop_number_of_panels += single_roof_number_of_panels
if self.simulation_model_type == 'explicit':
single_roof_pv_output = self.explicit_model(pv_system=self.pv_system,
inverter_efficiency=self.inverter_efficiency,
number_of_panels=single_roof_number_of_panels,
irradiance=roof.global_irradiance_tilted[cte.HOUR],
outdoor_temperature=self.building.external_temperature[
cte.HOUR])
for i in range(len(rooftops_pv_output)):
rooftops_pv_output[i] += single_roof_pv_output[i]
total_hourly_pv_output = [rooftops_pv_output[i] + facades_pv_output[i] for i in range(8760)]
results = {'building_name': self.building.name,
'total_floor_area_m2': self.building.thermal_zones_from_internal_zones[0].total_floor_area,
'roof_area_m2': self.building.roofs[0].perimeter_area, 'rooftop_panels': rooftop_number_of_panels,
'rooftop_panels_area_m2': self.building.roofs[0].installed_solar_collector_area,
'yearly_rooftop_ghi_kW/m2': self.building.roofs[0].global_irradiance[cte.YEAR][0] / 1000,
f'yearly_rooftop_tilted_radiation_{self.tilt_angle}_degree_kW/m2':
self.building.roofs[0].global_irradiance_tilted[cte.YEAR][0] / 1000,
'yearly_rooftop_pv_production_kWh': sum(rooftops_pv_output) / 1000,
'yearly_total_pv_production_kWh': sum(total_hourly_pv_output) / 1000,
'specific_pv_production_kWh/kWp': sum(rooftops_pv_output) / (
float(self.pv_system.standard_test_condition_maximum_power) * rooftop_number_of_panels),
'hourly_rooftop_poa_irradiance_W/m2': self.building.roofs[0].global_irradiance_tilted[cte.HOUR],
'hourly_rooftop_pv_output_W': rooftops_pv_output, 'T_out': self.building.external_temperature[cte.HOUR],
'total_hourly_pv_system_output_W': total_hourly_pv_output}
return results
def enrich(self):
system_archetype_name = self.building.energy_systems_archetype_name
archetype_name = '_'.join(system_archetype_name.lower().split())
if 'grid_tied' in archetype_name:
self.results = self.grid_tied_system()
for energy_system in self.building.energy_systems:
for generation_system in energy_system.generation_systems:
if generation_system.system_type == cte.PHOTOVOLTAIC:
generation_system.installed_capacity = (self.results['rooftop_panels'] *
float(generation_system.standard_test_condition_maximum_power))
hourly_pv_output = self.results['total_hourly_pv_system_output_W']
self.building.pv_generation[cte.HOUR] = hourly_pv_output
self.building.pv_generation[cte.MONTH] = MonthlyValues.get_total_month(hourly_pv_output)
self.building.pv_generation[cte.YEAR] = [sum(hourly_pv_output)]
if self.csv_output:
self.save_to_csv(self.results, self.output_path, f'{self.building.name}_pv_system_analysis.csv')
@staticmethod
def save_to_csv(data, output_path, filename='rooftop_system_results.csv'):
# Separate keys based on whether their values are single values or lists
single_value_keys = [key for key, value in data.items() if not isinstance(value, list)]
list_value_keys = [key for key, value in data.items() if isinstance(value, list)]
# Check if all lists have the same length
list_lengths = [len(data[key]) for key in list_value_keys]
if not all(length == list_lengths[0] for length in list_lengths):
raise ValueError("All lists in the dictionary must have the same length")
# Get the length of list values (assuming all lists are of the same length, e.g., 8760 for hourly data)
num_rows = list_lengths[0] if list_value_keys else 1
# Open the CSV file for writing
with open(output_path / filename, mode='w', newline='') as csv_file:
writer = csv.writer(csv_file)
# Write single-value data as a header section
for key in single_value_keys:
writer.writerow([key, data[key]])
# Write an empty row for separation
writer.writerow([])
# Write the header for the list values
writer.writerow(list_value_keys)
# Write each row for the lists
for i in range(num_rows):
row = [data[key][i] for key in list_value_keys]
writer.writerow(row)