hub/data/energy_systems/heat_pumps/air_source_tmpl.txt

817 lines
12 KiB
Plaintext
Raw Normal View History

B 10 MUL
64.1
183.1
B 11 MUL
198.1
167.1
163.1
162.1
B 12 MUL
201.1
24.1
B 13 MUL
70.1
180.1
B 14 MUL
184.1
34.1
B 15 MUL
198.1
165.1
163.1
162.1
B 16 MUL
186.1
40.1
B 17 MUL
79.1
56.1
69.1
B 18 MUL
188.1
49.1
B 19 MUL
46.1
158.1
B 20 MUL
72.1
66.1
B 21 MUL
57.1
182.1
B 22 MUL
203.2
43.1
B 23 MUL
78.1
50.1
47.1
B 24 MUL
201.1
193.1
196.1
B 25 MUL
203.2
76.1
B 26 MUL
58.1
68.1
B 27 MUL
160.1
63.1
168.1
136.1
B 28 MUL
58.1
60.1
B 29 MUL
65.1
181.1
B 30 MUL
203.2
58.1
36.1
B 31 MUL
159.1
195.1
B 32 MUL
203.2
58.1
77.1
B 33 MUL
202.1
74.1
B 34 CONST
P 34
$ElecGridEF % Constant value
B 35 CONST
P 35
5 % Constant value
B 36 CONST
P 36
$a3 % Constant value
B 37 CONST
P 37
$TemperatureDifference % Constant value
B 38 CONST
P 38
42 % Constant value
B 39 CONST
P 39
40 % Constant value
B 40 CONST
P 40
$ElectricityPrice % Constant value
B 41 CONST
P 41
9 % Constant value
B 42 CONST
P 42
12 % Constant value
B 43 CONST
P 43
$b2 % Constant value
B 44 CONST
P 44
$a6 % Constant value
B 45 CONST
P 45
55 % Constant value
B 46 CONST
P 46
$Cp % Constant value
B 47 CONST
P 47
$FuelEF % Constant value
B 48 CONST
P 48
2 % Constant value
B 49 CONST
P 49
1 % Constant value
B 50 CONST
P 50
300 % Constant value
B 51 CONST
P 51
10 % Constant value
B 52 CONST
P 52
0 % Constant value
B 53 CONST
P 53
12 % Constant value
B 54 CONST
P 54
$FuelLHV % Constant value
B 55 CONST
P 55
2 % Constant value
B 56 CONST
P 56
300 % Constant value
B 57 CONST
P 57
$b5 % Constant value
B 58 CONST
P 58
$HPSupTemp % Constant value
B 59 CONST
P 59
40 % Constant value
B 60 CONST
P 60
$a4 % Constant value
B 61 CONST
P 61
$b6 % Constant value
B 62 CONST
P 62
2 % Constant value
B 63 CONST
P 63
$Cp % Constant value
B 64 CONST
P 64
$b1 % Constant value
B 65 CONST
P 65
$a1 % Constant value
B 66 CONST
P 66
$TemperatureDifference % Constant value
B 67 CONST
P 67
$MaximumHPEnergyInput % Constant value
B 68 CONST
P 68
$b4 % Constant value
B 69 CONST
P 69
$FuelPrice % Constant value
B 70 CONST
P 70
$a5 % Constant value
B 71 CONST
P 71
2 % Constant value
B 72 CONST
P 72
$Cp % Constant value
B 73 CONST
P 73
$BuildingSuppTemp % Constant value
B 74 CONST
P 74
25 % Constant value
B 75 CONST
P 75
0 % Constant value
B 76 CONST
P 76
$a2 % Constant value
B 77 CONST
P 77
$b3 % Constant value
B 78 ATT
191.1
P 78
$FuelDensity % Attenuation factor a
B 79 ATT
191.1
P 79
$FuelDensity % Attenuation factor a
B 80 ATT
27.1
P 80
$AuxHeaterEfficiency % Attenuation factor a
B 81 ATT
191.1
P 81
$FuelDensity % Attenuation factor a
B 82 ATT
11.1
P 82
12 % Attenuation factor a
B 83 ATT
210.5
P 83
3600000 % Attenuation factor a
B 84 ATT
161.1
P 84
3600000 % Attenuation factor a
B 85 ATT
27.1
P 85
1000 % Attenuation factor a
B 125 WRITE
156.1
156.2
156.3
P 125
2 % Mode
0 % Suppress FNQ inputs
$fileOut7 % File name
'*' % Fortran format
B 126 WRITE
151.1
151.2
151.3
P 126
2 % Mode
0 % Suppress FNQ inputs
$fileOut2 % File name
'*' % Fortran format
B 127 WRITE
154.1
154.2
154.3
P 127
2 % Mode
0 % Suppress FNQ inputs
$fileOut3 % File name
'*' % Fortran format
B 128 WRITE
153.1
153.2
153.3
P 128
2 % Mode
0 % Suppress FNQ inputs
$fileOut5 % File name
'*' % Fortran format
B 129 WRITE
204.1
204.2
204.3
204.4
204.5
15.1
11.1
190.1
187.1
160.1
210.1
210.2
210.3
210.4
210.5
83.1
84.1
191.1
85.1
16.1
17.1
14.1
23.1
164.1
145.1
P 129
2 % Mode
0 % Suppress FNQ inputs
$fileOut1 % File name
'*' % Fortran format
B 130 WRITE
204.1
204.2
204.3
152.1
152.2
P 130
2 % Mode
0 % Suppress FNQ inputs
$fileOut10 % File name
'*' % Fortran format
B 131 WRITE
149.1
149.2
P 131
2 % Mode
0 % Suppress FNQ inputs
$fileOut9 % File name
'*' % Fortran format
B 132 WRITE
157.1
157.2
P 132
2 % Mode
0 % Suppress FNQ inputs
$fileOut8 % File name
'*' % Fortran format
B 133 WRITE
150.1
150.2
P 133
2 % Mode
0 % Suppress FNQ inputs
$fileOut4 % File name
'*' % Fortran format
B 134 WRITE
155.1
155.2
P 134
2 % Mode
0 % Suppress FNQ inputs
$fileOut6 % File name
'*' % Fortran format
B 135 LT
204.2
35.1
B 136 LT
210.1
39.1
%B 137 SCREEN
%176.1
%P 137
%'*' % Format
%'Total CO2 Emissions from Electricity Grid (g)' % Headline
%B 138 SCREEN
%178.1
%P 138
%'*' % Format
%'Total Electricity Cost in a Year (CAD)' % Headline
%B 139 SCREEN
%173.1
%P 139
%'*' % Format
%'Total Cost of the Auxiliary Heater Fuel in a Year (CAD)' % Headline
%B 140 SCREEN
%177.1
%P 140
%'*' % Format
%'Total CO2 Emissions from Auxiliary Heater (g)' % Headline
%B 141 SCREEN
%189.1
%P 141
%'*' % Format
%'HP Seasonal COP' % Headline
%B 142 SCREEN
%148.1
%P 142
%'*' % Format
%'Maximum Number of HPs in Operation' % Headline
%B 143 SCREEN
%174.1
%P 143
%'*' % Format
%'Total Electricuty Demand of Heat Pumps in a year (kWh)' % Headline
%B 144 SCREEN
%179.1
%P 144
%'*' % Format
%'Total Fossil Fuel consumption in a Year (m3)' % Headline
B 145 READ
P 145
1 % Number of values to be read per record
0 % Number of records to be skipped on the first call
$HeatingDemand % File name
'*' % Fortran format
B 146 DELAY
15.1
P 146
0 % Initial value
B 147 DELAY
210.5
P 147
0 % Initial value
B 148 MAXX
198.1
B 149 CUMC
204.3
205.1
B 150 CUMC
204.2
205.1
B 151 CUMC
204.3
14.1
23.1
B 152 CUMC
204.4
82.1
B 153 CUMC
204.2
14.1
23.1
B 154 CUMC
204.2
16.1
17.1
B 155 CUMC
204.3
82.1
B 156 CUMC
204.3
16.1
17.1
B 157 CUMC
204.2
82.1
B 158 SUM
58.1
169.1
B 159 SUM
170.1
210.1
B 160 SUM
18.1
75.1
B 161 SUM
210.5
172.1
B 162 SUM
12.1
200.1
B 163 SUM
135.1
197.1
B 164 SUM
31.1
33.1
B 165 SUM
29.1
25.1
30.1
28.1
13.1
44.1
B 166 SUM
51.1
203.2
B 167 SUM
10.1
22.1
32.1
26.1
21.1
61.1
B 168 SUM
73.1
171.1
B 169 CHS
210.4
B 170 CHS
37.1
B 171 CHS
210.1
B 172 CHS
147.1
B 173 CUM
17.1
B 174 CUM
82.1
B 175 CUM
15.1
11.1
B 176 CUM
14.1
B 177 CUM
23.1
B 178 CUM
16.1
B 179 CUM
205.1
B 180 EXPG
58.1
55.1
B 181 EXPG
203.2
71.1
B 182 EXPG
58.1
48.1
B 183 EXPG
203.2
62.1
B 184 DIV
11.1
53.1
B 185 DIV
67.1
165.1
B 186 DIV
11.1
42.1
B 187 DIV
206.1
19.1
B 188 DIV
207.1
20.1
B 189 DIV
175.1
175.2
B 190 DIV
15.1
11.1
B 191 DIV
80.1
54.1
B 192 GE
210.1
45.1
P 192
0 % Error tolerance
B 193 GE
210.1
38.1
P 193
0 % Error tolerance
B 194 SOY
204.1
204.2
204.3
204.4
204.5
204.6
B 195 GT
210.1
59.1
B 196 GT
146.1
52.1
B 197 GT
204.2
41.1
B 198 INT
185.1
B 199 MTM
204.2
P 199
'Montreal' % Location
B 200 INV
193.1
B 201 INV
192.1
B 202 INV
195.1
B 203 GENGT
199.1
199.3
199.4
199.5
199.7
199.8
204.1
204.2
204.3
204.4
P 203
45.5 % Latitude
73.62 % Longitude
5 % Time zone
1 % Variance factor of the Gordon Reddy correlation
0 % Year-to-year variability
0.3 % Autocorrelation coefficient lag one
0.171 % Autocorrelation coefficient lag two
4711 % Initialisation of random number generator
2 % Maximum allowed mean temperature deviation
100 % Maximum number of iterations
B 204 CLOCK
P 204
$StartYear % Start year
$StartMonth % Start month
$StartDay % Start day
$StartHour % Start hour
$StartMinute % Start minute
$StartSecond % Start second
$EndYear % End year
$EndMonth % End month
$EndDay % End day
$EndHour % End hour
$EndMinute % End minute
$EndSecond % End second
5 % Increment
'm' % Unit
B 205 GAIN
81.1
P 205
300 % Gain factor g
B 206 GAIN
15.1
P 206
1000 % Gain factor g
B 207 GAIN
145.1
P 207
1000 % Gain factor g
B 210 TANKST
58.1
187.1
164.1
160.1
166.1
194.1
P 210
$TESCapacity % Tank volume
4 % Number of temperature nodes
$TESDiameter % Tank diameter
$Cp % Specfic heat of fluid
$Rhow % Fluid density
0 % Overall heat-loss coefficient
1 % Effective heat conductivity
30 % Initial tank temperature