changing from generation system to generation systemS in system importer north america
This commit is contained in:
parent
fac6844da1
commit
087384475f
@ -86,33 +86,36 @@ class NorthAmericaCustomEnergySystemParameters:
|
||||
_hub_demand_types.append(Dictionaries().north_america_demand_type_to_hub_energy_demand_type[demand_type])
|
||||
energy_system.name = system.name
|
||||
energy_system.demand_types = _hub_demand_types
|
||||
_generation_system = GenericGenerationSystem()
|
||||
archetype_generation_equipment = system.generation_systems
|
||||
_type = system.name
|
||||
_generation_system.type = Dictionaries().north_america_system_to_hub_energy_generation_system[_type]
|
||||
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
|
||||
_generation_system.fuel_type = _fuel_type
|
||||
_generation_system.source_types = archetype_generation_equipment.source_medium
|
||||
_generation_system.heat_efficiency = archetype_generation_equipment.heat_efficiency
|
||||
_generation_system.cooling_efficiency = archetype_generation_equipment.cooling_efficiency
|
||||
_generation_system.electricity_efficiency = archetype_generation_equipment.electricity_efficiency
|
||||
_generation_system.source_temperature = archetype_generation_equipment.source_temperature
|
||||
_generation_system.source_mass_flow = archetype_generation_equipment.source_mass_flow
|
||||
_generation_system.storage = None
|
||||
_generation_system.auxiliary_equipment = None
|
||||
_generation_system._supply_medium = archetype_generation_equipment.supply_medium
|
||||
_generation_system._maximum_heat_supply_temperature = archetype_generation_equipment.maximum_heat_supply_temperature
|
||||
_generation_system._minimum_heat_supply_temperature = archetype_generation_equipment.minimum_heat_supply_temperature
|
||||
_generation_system._maximum_cooling_supply_temperature = archetype_generation_equipment.maximum_cooling_supply_temperature
|
||||
_generation_system._minimum_cooling_supply_temperature = archetype_generation_equipment.minimum_cooling_supply_temperature
|
||||
_generation_system._heat_output_curve = archetype_generation_equipment.heat_output_curve
|
||||
_generation_system._heat_fuel_consumption_curve = archetype_generation_equipment.heat_fuel_consumption_curve
|
||||
_generation_system._heat_efficiency_curve = archetype_generation_equipment.heat_efficiency_curve
|
||||
_generation_system._cooling_output_curve = archetype_generation_equipment.cooling_output_curve
|
||||
_generation_system._cooling_fuel_consumption_curve = archetype_generation_equipment.cooling_fuel_consumption_curve
|
||||
_generation_system._cooling_efficiency_curve = archetype_generation_equipment.cooling_efficiency_curve
|
||||
archetype_generation_equipments = system.generation_systems
|
||||
_generation_systems = []
|
||||
for archetype_generation_equipment in archetype_generation_equipments:
|
||||
_generation_system = GenericGenerationSystem()
|
||||
_type = archetype_generation_equipment.name
|
||||
_generation_system.type = Dictionaries().north_america_system_to_hub_energy_generation_system[_type]
|
||||
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
|
||||
_generation_system.fuel_type = _fuel_type
|
||||
_generation_system.source_types = archetype_generation_equipment.source_medium
|
||||
_generation_system.heat_efficiency = archetype_generation_equipment.heat_efficiency
|
||||
_generation_system.cooling_efficiency = archetype_generation_equipment.cooling_efficiency
|
||||
_generation_system.electricity_efficiency = archetype_generation_equipment.electricity_efficiency
|
||||
_generation_system.source_temperature = archetype_generation_equipment.source_temperature
|
||||
_generation_system.source_mass_flow = archetype_generation_equipment.source_mass_flow
|
||||
_generation_system.storage = None
|
||||
_generation_system.auxiliary_equipment = None
|
||||
_generation_system._supply_medium = archetype_generation_equipment.supply_medium
|
||||
_generation_system._maximum_heat_supply_temperature = archetype_generation_equipment.maximum_heat_supply_temperature
|
||||
_generation_system._minimum_heat_supply_temperature = archetype_generation_equipment.minimum_heat_supply_temperature
|
||||
_generation_system._maximum_cooling_supply_temperature = archetype_generation_equipment.maximum_cooling_supply_temperature
|
||||
_generation_system._minimum_cooling_supply_temperature = archetype_generation_equipment.minimum_cooling_supply_temperature
|
||||
_generation_system._heat_output_curve = archetype_generation_equipment.heat_output_curve
|
||||
_generation_system._heat_fuel_consumption_curve = archetype_generation_equipment.heat_fuel_consumption_curve
|
||||
_generation_system._heat_efficiency_curve = archetype_generation_equipment.heat_efficiency_curve
|
||||
_generation_system._cooling_output_curve = archetype_generation_equipment.cooling_output_curve
|
||||
_generation_system._cooling_fuel_consumption_curve = archetype_generation_equipment.cooling_fuel_consumption_curve
|
||||
_generation_system._cooling_efficiency_curve = archetype_generation_equipment.cooling_efficiency_curve
|
||||
_generation_systems.append(_generation_system)
|
||||
|
||||
energy_system.generation_system = _generation_system
|
||||
energy_system.generation_systems = _generation_systems
|
||||
|
||||
_thermal_storage_system = ThermalStorageSystem()
|
||||
archetype_storage_equipment = system.energy_storage_systems
|
||||
|
@ -9,6 +9,7 @@ from pathlib import Path
|
||||
|
||||
from hub.helpers.utils import validate_import_export_type
|
||||
from hub.imports.energy_systems.montreal_custom_energy_system_parameters import MontrealCustomEnergySystemParameters
|
||||
from hub.imports.energy_systems.north_america_custom_energy_system_parameters import NorthAmericaCustomEnergySystemParameters
|
||||
|
||||
|
||||
class EnergySystemsFactory:
|
||||
@ -37,7 +38,7 @@ class EnergySystemsFactory:
|
||||
"""
|
||||
Enrich the city by using north america custom energy systems catalog information
|
||||
"""
|
||||
MontrealCustomEnergySystemParameters(self._city).enrich_buildings()
|
||||
NorthAmericaCustomEnergySystemParameters(self._city).enrich_buildings()
|
||||
self._city.level_of_detail.energy_systems = 2
|
||||
for building in self._city.buildings:
|
||||
building.level_of_detail.energy_systems = 2
|
||||
|
Loading…
Reference in New Issue
Block a user