From 33049441f0e6caa47f18d14386788ed7bf57b8f6 Mon Sep 17 00:00:00 2001 From: Koa Wells Date: Tue, 1 Oct 2024 14:35:08 -0500 Subject: [PATCH] Add build package to setup.py and remove texttest --- setup.py | 2 +- texttest | 142 ------------------------------------------------------- 2 files changed, 1 insertion(+), 143 deletions(-) delete mode 100644 texttest diff --git a/setup.py b/setup.py index 7c2df9ca..8af11db8 100644 --- a/setup.py +++ b/setup.py @@ -10,7 +10,7 @@ with pathlib.Path('requirements.txt').open() as r: for requirement in r.readlines() ] -install_requires.append('setuptools') +install_requires.append('setuptools, build') main_ns = {} version = convert_path('hub/version.py') diff --git a/texttest b/texttest deleted file mode 100644 index b5147f2b..00000000 --- a/texttest +++ /dev/null @@ -1,142 +0,0 @@ -ZoneControl:Thermostat, - Room_180_7ad8616b Thermostat, !- Name - Room_180_7ad8616b, !- Zone or ZoneList Name - Room_180_7ad8616b Thermostat Schedule, !- Control Type Schedule Name - ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type - LargeOffice Building_Setpoint 26, !- Control 1 Name - , !- Control 2 Object Type - , !- Control 2 Name - , !- Control 3 Object Type - , !- Control 3 Name - , !- Control 4 Object Type - , !- Control 4 Name - 0; !- Temperature Difference Between Cutout And Setpoint {deltaC} - -Schedule:Compact, - Room_180_7ad8616b Thermostat Schedule, !- Name - Room_180_7ad8616b Thermostat Schedule Type Limits, !- Schedule Type Limits Name - Through: 12/31, !- Field 1 - For: AllDays, !- Field 2 - Until: 24:00, !- Field 3 - 4; !- Field 4 - -ScheduleTypeLimits, - Room_180_7ad8616b Thermostat Schedule Type Limits, !- Name - 0, !- Lower Limit Value {BasedOnField A3} - 4, !- Upper Limit Value {BasedOnField A3} - DISCRETE; !- Numeric Type - -ThermostatSetpoint:DualSetpoint, - LargeOffice Building_Setpoint 26, !- Name - LargeOffice Building_Setpoint_HtgSetp Schedule, !- Heating Setpoint Temperature Schedule Name - LargeOffice Building_Setpoint_ClgSetp Schedule; !- Cooling Setpoint Temperature Schedule Name - -ZoneHVAC:EquipmentConnections, - Room_180_7ad8616b, !- Zone Name - Room_180_7ad8616b Equipment List, !- Zone Conditioning Equipment List Name - Room_180_7ad8616b Inlet Node List, !- Zone Air Inlet Node or NodeList Name - , !- Zone Air Exhaust Node or NodeList Name - Node 27, !- Zone Air Node Name - Room_180_7ad8616b Return Node List; !- Zone Return Air Node or NodeList Name - -NodeList, - Room_180_7ad8616b Inlet Node List, !- Name - Node 305; !- Node Name 1 - -NodeList, - Room_180_7ad8616b Return Node List, !- Name - Node 308; !- Node Name 1 - -ZoneHVAC:Baseboard:Convective:Electric, - Elec Baseboard 1, !- Name - Always On Discrete hvac_library, !- Availability Schedule Name - , !- Heating Design Capacity Method - Autosize, !- Heating Design Capacity {W} - , !- Heating Design Capacity Per Floor Area {W/m2} - , !- Fraction of Autosized Heating Design Capacity - 1; !- Efficiency - -AirTerminal:SingleDuct:ConstantVolume:NoReheat, - Diffuser 21, !- Name - Always On Discrete hvac_library, !- Availability Schedule Name - Node 307, !- Air Inlet Node Name - Node 305, !- Air Outlet Node Name - AutoSize; !- Maximum Air Flow Rate {m3/s} - -ZoneHVAC:AirDistributionUnit, - ADU Diffuser 21, !- Name - Node 305, !- Air Distribution Unit Outlet Node Name - AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type - Diffuser 21; !- Air Terminal Name - -ZoneHVAC:EquipmentList, - Room_180_7ad8616b Equipment List, !- Name - SequentialLoad, !- Load Distribution Scheme - ZoneHVAC:Baseboard:Convective:Electric, !- Zone Equipment Object Type 1 - Elec Baseboard 1, !- Zone Equipment Name 1 - 1, !- Zone Equipment Cooling Sequence 1 - 1, !- Zone Equipment Heating or No-Load Sequence 1 - , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 - , !- Zone Equipment Sequential Heating Fraction Schedule Name 1 - ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type 2 - ADU Diffuser 21, !- Zone Equipment Name 2 - 2, !- Zone Equipment Cooling Sequence 2 - 2, !- Zone Equipment Heating or No-Load Sequence 2 - , !- Zone Equipment Sequential Cooling Fraction Schedule Name 2 - ; !- Zone Equipment Sequential Heating Fraction Schedule Name 2 - -Sizing:Zone, - Room_180_7ad8616b, !- Zone or ZoneList Name - SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method - 14, !- Zone Cooling Design Supply Air Temperature {C} - 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC} - SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method - 40, !- Zone Heating Design Supply Air Temperature {C} - 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC} - 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} - 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} - Room_180_7ad8616b DSOA Space List, !- Design Specification Outdoor Air Object Name - , !- Zone Heating Sizing Factor - , !- Zone Cooling Sizing Factor - DesignDay, !- Cooling Design Air Flow Method - 0, !- Cooling Design Air Flow Rate {m3/s} - 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} - 0, !- Cooling Minimum Air Flow {m3/s} - 0, !- Cooling Minimum Air Flow Fraction - DesignDay, !- Heating Design Air Flow Method - 0, !- Heating Design Air Flow Rate {m3/s} - 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} - 0.1415762, !- Heating Maximum Air Flow {m3/s} - 0.3, !- Heating Maximum Air Flow Fraction - , !- Design Specification Zone Air Distribution Object Name - No, !- Account for Dedicated Outdoor Air System - , !- Dedicated Outdoor Air System Control Strategy - , !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} - , !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} - Sensible Load Only No Latent Load, !- Zone Load Sizing Method - HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method - , !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir} - 0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir} - HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method - , !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir} - 0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir} - -DesignSpecification:OutdoorAir:SpaceList, - Room_180_7ad8616b DSOA Space List, !- Name - Room_180_7ad8616b_Space, !- Space Name 1 - MidriseApartment Apartment Ventilation; !- Space Design Specification Outdoor Air Object Name 1 - -Zone, - Room_181_3a411b5d, !- Name - , !- Direction of Relative North {deg} - 0, !- X Origin {m} - 0, !- Y Origin {m} - 0, !- Z Origin {m} - , !- Type - 1, !- Multiplier - 4, !- Ceiling Height {m} - 291.62935408288, !- Volume {m3} - , !- Floor Area {m2} - , !- Zone Inside Convection Algorithm - , !- Zone Outside Convection Algorithm - Yes; !- Part of Total Floor Area \ No newline at end of file