Incorporated infiltration per area to all the archetypes
This commit is contained in:
parent
5f0fae0722
commit
726070d503
@ -8,6 +8,8 @@
|
||||
"extra_loses_due_thermal_bridges": 0.1,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.9,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.006,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "residential_1000_1980_BWh",
|
||||
@ -42,6 +44,8 @@
|
||||
"extra_loses_due_thermal_bridges": 0.1,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.31,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.002,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "dormitory_2011_3000_BWh",
|
||||
@ -76,6 +80,8 @@
|
||||
"extra_loses_due_thermal_bridges": 0.09,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.65,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.004,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "hotel_employees_1981_2010_BWh",
|
||||
|
@ -21,6 +21,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -44,6 +46,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -67,6 +71,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -89,6 +95,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -111,6 +119,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -133,6 +143,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -155,6 +167,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -177,6 +191,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -199,6 +215,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -221,6 +239,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -243,6 +263,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -265,6 +287,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -287,6 +311,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -309,6 +335,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -331,6 +359,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -353,6 +383,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -375,6 +407,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -397,6 +431,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -419,6 +455,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -441,6 +479,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -463,6 +503,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -485,6 +527,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -507,6 +551,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -529,6 +575,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -551,6 +599,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -573,6 +623,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -595,6 +647,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -617,6 +671,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -639,6 +695,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -661,6 +719,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -683,6 +743,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -705,6 +767,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -727,6 +791,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -749,6 +815,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="35" building_type="residential" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -771,6 +839,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="36" building_type="residential" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -793,6 +863,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="37" building_type="industry" reference_standard="non_standard_dompark" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -815,5 +887,7 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
</archetypes>
|
||||
|