@ -116,7 +116,7 @@ class NrcanCatalog(Catalog):
|
||||||
climate_zone = archetype['climate_zone']
|
climate_zone = archetype['climate_zone']
|
||||||
construction_period = archetype['period_of_construction']
|
construction_period = archetype['period_of_construction']
|
||||||
average_storey_height = archetype['average_storey_height']
|
average_storey_height = archetype['average_storey_height']
|
||||||
thermal_capacity = str(float(archetype['thermal_capacity']) * 1000)
|
thermal_capacity = float(archetype['thermal_capacity']) * 1000
|
||||||
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
|
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
|
||||||
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off']
|
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off']
|
||||||
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on']
|
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on']
|
||||||
|
|
|
@ -53,7 +53,7 @@ class NrcanCatalog(Catalog):
|
||||||
|
|
||||||
def _load_schedules(self):
|
def _load_schedules(self):
|
||||||
usage = self._metadata['nrcan']
|
usage = self._metadata['nrcan']
|
||||||
url = f'{self._base_url}{usage["schedules_location"]}'
|
url = f'{self._base_url}{usage["schedules"]}'
|
||||||
_schedule_types = []
|
_schedule_types = []
|
||||||
with urllib.request.urlopen(url) as json_file:
|
with urllib.request.urlopen(url) as json_file:
|
||||||
schedules_type = json.load(json_file)
|
schedules_type = json.load(json_file)
|
||||||
|
@ -76,12 +76,40 @@ class NrcanCatalog(Catalog):
|
||||||
def _load_archetypes(self):
|
def _load_archetypes(self):
|
||||||
usages = []
|
usages = []
|
||||||
name = self._metadata['nrcan']
|
name = self._metadata['nrcan']
|
||||||
url = f'{self._base_url}{name["space_types_location"]}'
|
url_1 = f'{self._base_url}{name["space_types"]}'
|
||||||
with urllib.request.urlopen(url) as json_file:
|
url_2 = f'{self._base_url}{name["space_types_compliance"]}'
|
||||||
|
with urllib.request.urlopen(url_1) as json_file:
|
||||||
space_types = json.load(json_file)['tables']['space_types']['table']
|
space_types = json.load(json_file)['tables']['space_types']['table']
|
||||||
space_types = [st for st in space_types if st['space_type'] == 'WholeBuilding']
|
space_types = [st for st in space_types if st['space_type'] == 'WholeBuilding']
|
||||||
|
with urllib.request.urlopen(url_2) as json_file:
|
||||||
|
space_types_compliance = json.load(json_file)['tables']['space_compliance']['table']
|
||||||
|
space_types_compliance = [st for st in space_types_compliance if st['space_type'] == 'WholeBuilding']
|
||||||
|
space_types_dictionary = {}
|
||||||
|
for space_type in space_types_compliance:
|
||||||
|
usage_type = space_type['building_type']
|
||||||
|
# people/m2
|
||||||
|
occupancy_density = space_type['occupancy_per_area_people_per_m2']
|
||||||
|
# W/m2
|
||||||
|
lighting_density = space_type['lighting_per_area_w_per_m2']
|
||||||
|
# W/m2
|
||||||
|
appliances_density = space_type['electric_equipment_per_area_w_per_m2']
|
||||||
|
# peak flow in gallons/h/m2
|
||||||
|
domestic_hot_water_peak_flow = space_type['service_water_heating_peak_flow_per_area'] \
|
||||||
|
* cte.GALLONS_TO_QUBIC_METERS / cte.HOUR_TO_SECONDS
|
||||||
|
space_types_dictionary[usage_type] = {'occupancy_per_area': occupancy_density,
|
||||||
|
'lighting_per_area': lighting_density,
|
||||||
|
'electric_equipment_per_area': appliances_density,
|
||||||
|
'service_water_heating_peak_flow_per_area': domestic_hot_water_peak_flow
|
||||||
|
}
|
||||||
|
|
||||||
for space_type in space_types:
|
for space_type in space_types:
|
||||||
usage_type = space_type['building_type']
|
usage_type = space_type['building_type']
|
||||||
|
space_type_compliance = space_types_dictionary[usage_type]
|
||||||
|
occupancy_density = space_type_compliance['occupancy_per_area']
|
||||||
|
lighting_density = space_type_compliance['lighting_per_area']
|
||||||
|
appliances_density = space_type_compliance['electric_equipment_per_area']
|
||||||
|
domestic_hot_water_peak_flow = space_type_compliance['service_water_heating_peak_flow_per_area']
|
||||||
|
|
||||||
occupancy_schedule_name = space_type['occupancy_schedule']
|
occupancy_schedule_name = space_type['occupancy_schedule']
|
||||||
lighting_schedule_name = space_type['lighting_schedule']
|
lighting_schedule_name = space_type['lighting_schedule']
|
||||||
appliance_schedule_name = space_type['electric_equipment_schedule']
|
appliance_schedule_name = space_type['electric_equipment_schedule']
|
||||||
|
@ -99,35 +127,26 @@ class NrcanCatalog(Catalog):
|
||||||
hvac_availability = self._get_schedules(hvac_schedule_name)
|
hvac_availability = self._get_schedules(hvac_schedule_name)
|
||||||
domestic_hot_water_load_schedule = self._get_schedules(domestic_hot_water_schedule_name)
|
domestic_hot_water_load_schedule = self._get_schedules(domestic_hot_water_schedule_name)
|
||||||
|
|
||||||
occupancy_density = space_type['occupancy_per_area']
|
|
||||||
|
|
||||||
# ACH
|
# ACH
|
||||||
mechanical_air_change = space_type['ventilation_air_changes']
|
mechanical_air_change = space_type['ventilation_air_changes']
|
||||||
# cfm/ft2 to m3/m2.s
|
# cfm/ft2 to m3/m2.s
|
||||||
ventilation_rate = space_type['ventilation_per_area'] / (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)
|
ventilation_rate = space_type['ventilation_per_area'] / (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)
|
||||||
if ventilation_rate == 0:
|
if ventilation_rate == 0:
|
||||||
# cfm/person to m3/m2.s
|
# cfm/person to m3/m2.s
|
||||||
ventilation_rate = space_type['ventilation_per_person'] / occupancy_density\
|
ventilation_rate = space_type['ventilation_per_person'] / (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)\
|
||||||
/ (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)
|
/ occupancy_density
|
||||||
|
|
||||||
# W/sqft to W/m2
|
|
||||||
lighting_density = space_type['lighting_per_area'] * cte.METERS_TO_FEET * cte.METERS_TO_FEET
|
|
||||||
lighting_radiative_fraction = space_type['lighting_fraction_radiant']
|
lighting_radiative_fraction = space_type['lighting_fraction_radiant']
|
||||||
lighting_convective_fraction = 0
|
lighting_convective_fraction = 0
|
||||||
if lighting_radiative_fraction is not None:
|
if lighting_radiative_fraction is not None:
|
||||||
lighting_convective_fraction = 1 - lighting_radiative_fraction
|
lighting_convective_fraction = 1 - lighting_radiative_fraction
|
||||||
lighting_latent_fraction = 0
|
lighting_latent_fraction = 0
|
||||||
# W/sqft to W/m2
|
|
||||||
appliances_density = space_type['electric_equipment_per_area'] * cte.METERS_TO_FEET * cte.METERS_TO_FEET
|
|
||||||
appliances_radiative_fraction = space_type['electric_equipment_fraction_radiant']
|
appliances_radiative_fraction = space_type['electric_equipment_fraction_radiant']
|
||||||
appliances_latent_fraction = space_type['electric_equipment_fraction_latent']
|
appliances_latent_fraction = space_type['electric_equipment_fraction_latent']
|
||||||
appliances_convective_fraction = 0
|
appliances_convective_fraction = 0
|
||||||
if appliances_radiative_fraction is not None and appliances_latent_fraction is not None:
|
if appliances_radiative_fraction is not None and appliances_latent_fraction is not None:
|
||||||
appliances_convective_fraction = 1 - appliances_radiative_fraction - appliances_latent_fraction
|
appliances_convective_fraction = 1 - appliances_radiative_fraction - appliances_latent_fraction
|
||||||
|
|
||||||
# peak flow in gallons/h/ft2
|
|
||||||
domestic_hot_water_peak_flow = space_type['service_water_heating_peak_flow_per_area'] \
|
|
||||||
* cte.GALLONS_TO_QUBIC_METERS / cte.HOUR_TO_SECONDS * pow(cte.METERS_TO_FEET, 2)
|
|
||||||
domestic_hot_water_service_temperature = space_type['service_water_heating_target_temperature']
|
domestic_hot_water_service_temperature = space_type['service_water_heating_target_temperature']
|
||||||
|
|
||||||
occupancy = Occupancy(occupancy_density,
|
occupancy = Occupancy(occupancy_density,
|
||||||
|
|
|
@ -1,5 +1,6 @@
|
||||||
<?xml version="1.0" encoding="UTF-8" ?>
|
<?xml version="1.0" encoding="UTF-8" ?>
|
||||||
<nrcan base_url="https://raw.githubusercontent.com/NREL/openstudio-standards/master/lib/openstudio-standards/standards/necb/">
|
<nrcan base_url="https://raw.githubusercontent.com/NREL/openstudio-standards/master/lib/openstudio-standards/standards/necb/">
|
||||||
<space_types_location>NECB2020/data/space_types.json</space_types_location>
|
<space_types>NECB2015/data/space_types.json</space_types>
|
||||||
<schedules_location>NECB2015/data/schedules.json</schedules_location>
|
<space_types_compliance>NECB2015/qaqc/qaqc_data/space_compliance_2015.json</space_types_compliance>>
|
||||||
|
<schedules>NECB2015/data/schedules.json</schedules>
|
||||||
</nrcan>
|
</nrcan>
|
|
@ -70,10 +70,11 @@ class InselMonthlyEnergyBalance(Insel):
|
||||||
for i in range(1, len(surfaces) + 1):
|
for i in range(1, len(surfaces) + 1):
|
||||||
inputs.append(f"{str(100 + i)}.1 % Radiation surface {str(i)}")
|
inputs.append(f"{str(100 + i)}.1 % Radiation surface {str(i)}")
|
||||||
|
|
||||||
|
number_of_storeys = int(building.eave_height / building.average_storey_height)
|
||||||
# BUILDING PARAMETERS
|
# BUILDING PARAMETERS
|
||||||
parameters = [f'{0.85 * building.volume} % BP(1) Heated Volume (m3)',
|
parameters = [f'{building.volume} % BP(1) Heated Volume (m3)',
|
||||||
f'{building.average_storey_height} % BP(2) Average storey height (m)',
|
f'{building.average_storey_height} % BP(2) Average storey height (m)',
|
||||||
f'{building.storeys_above_ground} % BP(3) Number of storeys above ground',
|
f'{number_of_storeys} % BP(3) Number of storeys above ground',
|
||||||
f'{building.attic_heated} % BP(4) Attic heating type (0=no room, 1=unheated, 2=heated)',
|
f'{building.attic_heated} % BP(4) Attic heating type (0=no room, 1=unheated, 2=heated)',
|
||||||
f'{building.basement_heated} % BP(5) Cellar heating type (0=no room, 1=unheated, 2=heated, '
|
f'{building.basement_heated} % BP(5) Cellar heating type (0=no room, 1=unheated, 2=heated, '
|
||||||
f'99=invalid)']
|
f'99=invalid)']
|
||||||
|
@ -93,11 +94,11 @@ class InselMonthlyEnergyBalance(Insel):
|
||||||
|
|
||||||
for i, usage in enumerate(internal_zone.usages):
|
for i, usage in enumerate(internal_zone.usages):
|
||||||
percentage_usage = usage.percentage
|
percentage_usage = usage.percentage
|
||||||
parameters.append(f'{float(internal_zone.area) * percentage_usage} % BP(11) #1 Area of zone {i + 1} (m2)')
|
parameters.append(f'{internal_zone.thermal_zones[0].total_floor_area * percentage_usage} '
|
||||||
|
f'% BP(11) #1 Area of zone {i + 1} (m2)')
|
||||||
total_internal_gain = 0
|
total_internal_gain = 0
|
||||||
for ig in usage.internal_gains:
|
for ig in usage.internal_gains:
|
||||||
total_internal_gain += float(ig.average_internal_gain) * \
|
total_internal_gain += ig.average_internal_gain * (ig.convective_fraction + ig.radiative_fraction)
|
||||||
(float(ig.convective_fraction) + float(ig.radiative_fraction))
|
|
||||||
parameters.append(f'{total_internal_gain} % BP(12) #2 Internal gains of zone {i + 1}')
|
parameters.append(f'{total_internal_gain} % BP(12) #2 Internal gains of zone {i + 1}')
|
||||||
parameters.append(f'{usage.thermal_control.mean_heating_set_point} % BP(13) #3 Heating setpoint temperature '
|
parameters.append(f'{usage.thermal_control.mean_heating_set_point} % BP(13) #3 Heating setpoint temperature '
|
||||||
f'zone {i + 1} (degree Celsius)')
|
f'zone {i + 1} (degree Celsius)')
|
||||||
|
@ -107,7 +108,9 @@ class InselMonthlyEnergyBalance(Insel):
|
||||||
f'zone {i + 1} (degree Celsius)')
|
f'zone {i + 1} (degree Celsius)')
|
||||||
parameters.append(f'{usage.hours_day} % BP(16) #6 Usage hours per day zone {i + 1}')
|
parameters.append(f'{usage.hours_day} % BP(16) #6 Usage hours per day zone {i + 1}')
|
||||||
parameters.append(f'{usage.days_year} % BP(17) #7 Usage days per year zone {i + 1}')
|
parameters.append(f'{usage.days_year} % BP(17) #7 Usage days per year zone {i + 1}')
|
||||||
parameters.append(f'{usage.mechanical_air_change} % BP(18) #8 Minimum air change rate zone {i + 1} (ACH)')
|
|
||||||
|
ventilation_infiltration = usage.mechanical_air_change + internal_zone.thermal_zones[0].infiltration_rate_system_off
|
||||||
|
parameters.append(f'{ventilation_infiltration} % BP(18) #8 Minimum air change rate zone {i + 1} (ACH)')
|
||||||
|
|
||||||
parameters.append(f'{len(thermal_zone.thermal_boundaries)} % Number of surfaces = BP(11+8z) \n'
|
parameters.append(f'{len(thermal_zone.thermal_boundaries)} % Number of surfaces = BP(11+8z) \n'
|
||||||
f'% 1. Surface type (1=wall, 2=ground 3=roof, 4=flat roof)\n'
|
f'% 1. Surface type (1=wall, 2=ground 3=roof, 4=flat roof)\n'
|
||||||
|
@ -123,17 +126,18 @@ class InselMonthlyEnergyBalance(Insel):
|
||||||
|
|
||||||
for thermal_boundary in thermal_zone.thermal_boundaries:
|
for thermal_boundary in thermal_zone.thermal_boundaries:
|
||||||
type_code = _CONSTRUCTION_CODE[thermal_boundary.type]
|
type_code = _CONSTRUCTION_CODE[thermal_boundary.type]
|
||||||
window_area = 0
|
wall_area = thermal_boundary.opaque_area * (1 + thermal_boundary.window_ratio)
|
||||||
if thermal_boundary.window_ratio < 1:
|
if thermal_boundary.type == cte.WALL:
|
||||||
window_area = thermal_boundary.opaque_area * thermal_boundary.window_ratio / (1 - thermal_boundary.window_ratio)
|
wall_area = wall_area * (1 - thermal_boundary.parent_surface.percentage_shared)
|
||||||
|
window_area = wall_area * thermal_boundary.window_ratio
|
||||||
|
|
||||||
parameters.append(type_code)
|
parameters.append(type_code)
|
||||||
if thermal_boundary.type != cte.GROUND:
|
if thermal_boundary.type != cte.GROUND:
|
||||||
parameters.append(thermal_boundary.opaque_area + window_area)
|
parameters.append(wall_area)
|
||||||
parameters.append('0.0')
|
parameters.append('0.0')
|
||||||
else:
|
else:
|
||||||
parameters.append('0.0')
|
parameters.append('0.0')
|
||||||
parameters.append(thermal_boundary.opaque_area + window_area)
|
parameters.append(wall_area)
|
||||||
parameters.append(thermal_boundary.u_value)
|
parameters.append(thermal_boundary.u_value)
|
||||||
parameters.append(window_area)
|
parameters.append(window_area)
|
||||||
|
|
||||||
|
|
|
@ -76,7 +76,7 @@ class ComnetUsageParameters:
|
||||||
# usage.occupancy when writing usage.occupancy = archetype.occupancy.
|
# usage.occupancy when writing usage.occupancy = archetype.occupancy.
|
||||||
# Same happens for lighting and appliances. Therefore, this walk around has been done.
|
# Same happens for lighting and appliances. Therefore, this walk around has been done.
|
||||||
usage.mechanical_air_change = archetype.ventilation_rate / volume_per_area \
|
usage.mechanical_air_change = archetype.ventilation_rate / volume_per_area \
|
||||||
* cte.HOUR_TO_MINUTES * cte.MINUTES_TO_SECONDS
|
* cte.HOUR_TO_SECONDS
|
||||||
_occupancy = Occupancy()
|
_occupancy = Occupancy()
|
||||||
_occupancy.occupancy_density = archetype.occupancy.occupancy_density
|
_occupancy.occupancy_density = archetype.occupancy.occupancy_density
|
||||||
_occupancy.sensible_radiative_internal_gain = archetype.occupancy.sensible_radiative_internal_gain
|
_occupancy.sensible_radiative_internal_gain = archetype.occupancy.sensible_radiative_internal_gain
|
||||||
|
@ -106,11 +106,13 @@ class ComnetUsageParameters:
|
||||||
_domestic_hot_water = DomesticHotWater()
|
_domestic_hot_water = DomesticHotWater()
|
||||||
_domestic_hot_water.density = archetype.domestic_hot_water.density
|
_domestic_hot_water.density = archetype.domestic_hot_water.density
|
||||||
_domestic_hot_water.service_temperature = archetype.domestic_hot_water.service_temperature
|
_domestic_hot_water.service_temperature = archetype.domestic_hot_water.service_temperature
|
||||||
cold_temperature = cold_water_temperature[cte.YEAR]['epw']
|
peak_flow = None
|
||||||
peak_flow = 0
|
if len(cold_water_temperature) > 0:
|
||||||
if (archetype.domestic_hot_water.service_temperature - cold_temperature) > 0:
|
cold_temperature = cold_water_temperature[cte.YEAR]['epw']
|
||||||
peak_flow = archetype.domestic_hot_water.density / cte.WATER_DENSITY / cte.WATER_HEAT_CAPACITY \
|
peak_flow = 0
|
||||||
/ (archetype.domestic_hot_water.service_temperature - cold_temperature)
|
if (archetype.domestic_hot_water.service_temperature - cold_temperature) > 0:
|
||||||
|
peak_flow = archetype.domestic_hot_water.density / cte.WATER_DENSITY / cte.WATER_HEAT_CAPACITY \
|
||||||
|
/ (archetype.domestic_hot_water.service_temperature - cold_temperature)
|
||||||
_domestic_hot_water.peak_flow = peak_flow
|
_domestic_hot_water.peak_flow = peak_flow
|
||||||
_domestic_hot_water.schedules = archetype.domestic_hot_water.schedules
|
_domestic_hot_water.schedules = archetype.domestic_hot_water.schedules
|
||||||
usage.domestic_hot_water = _domestic_hot_water
|
usage.domestic_hot_water = _domestic_hot_water
|
||||||
|
|
|
@ -64,7 +64,7 @@ class NrcanUsageParameters:
|
||||||
usage = Usage()
|
usage = Usage()
|
||||||
usage.name = usage_name
|
usage.name = usage_name
|
||||||
self._assign_values(usage, archetype_usage, volume_per_area, building.cold_water_temperature)
|
self._assign_values(usage, archetype_usage, volume_per_area, building.cold_water_temperature)
|
||||||
self._assign_comnet_extra_values(usage, comnet_archetype_usage)
|
self._assign_comnet_extra_values(usage, comnet_archetype_usage, archetype_usage.occupancy.occupancy_density)
|
||||||
usage.percentage = 1
|
usage.percentage = 1
|
||||||
self._calculate_reduced_values_from_extended_library(usage, archetype_usage)
|
self._calculate_reduced_values_from_extended_library(usage, archetype_usage)
|
||||||
|
|
||||||
|
@ -83,8 +83,8 @@ class NrcanUsageParameters:
|
||||||
if archetype.mechanical_air_change > 0:
|
if archetype.mechanical_air_change > 0:
|
||||||
usage.mechanical_air_change = archetype.mechanical_air_change
|
usage.mechanical_air_change = archetype.mechanical_air_change
|
||||||
elif archetype.ventilation_rate > 0:
|
elif archetype.ventilation_rate > 0:
|
||||||
usage.mechanical_air_change = archetype.ventilation_rate / volume_per_area \
|
print(volume_per_area)
|
||||||
* cte.HOUR_TO_MINUTES * cte.MINUTES_TO_SECONDS
|
usage.mechanical_air_change = archetype.ventilation_rate / volume_per_area * cte.HOUR_TO_SECONDS
|
||||||
else:
|
else:
|
||||||
usage.mechanical_air_change = 0
|
usage.mechanical_air_change = 0
|
||||||
_occupancy = Occupancy()
|
_occupancy = Occupancy()
|
||||||
|
@ -116,18 +116,24 @@ class NrcanUsageParameters:
|
||||||
_domestic_hot_water = DomesticHotWater()
|
_domestic_hot_water = DomesticHotWater()
|
||||||
_domestic_hot_water.peak_flow = archetype.domestic_hot_water.peak_flow
|
_domestic_hot_water.peak_flow = archetype.domestic_hot_water.peak_flow
|
||||||
_domestic_hot_water.service_temperature = archetype.domestic_hot_water.service_temperature
|
_domestic_hot_water.service_temperature = archetype.domestic_hot_water.service_temperature
|
||||||
cold_temperature = cold_water_temperature[cte.YEAR]['epw']
|
density = None
|
||||||
_domestic_hot_water.density = archetype.domestic_hot_water.peak_flow * cte.WATER_DENSITY * cte.WATER_HEAT_CAPACITY \
|
if len(cold_water_temperature) > 0:
|
||||||
* (archetype.domestic_hot_water.service_temperature - cold_temperature)
|
cold_temperature = cold_water_temperature[cte.YEAR]['epw']
|
||||||
|
density = archetype.domestic_hot_water.peak_flow * cte.WATER_DENSITY * cte.WATER_HEAT_CAPACITY \
|
||||||
|
* (archetype.domestic_hot_water.service_temperature - cold_temperature)
|
||||||
|
_domestic_hot_water.density = density
|
||||||
_domestic_hot_water.schedules = archetype.domestic_hot_water.schedules
|
_domestic_hot_water.schedules = archetype.domestic_hot_water.schedules
|
||||||
usage.domestic_hot_water = _domestic_hot_water
|
usage.domestic_hot_water = _domestic_hot_water
|
||||||
|
|
||||||
@staticmethod
|
@staticmethod
|
||||||
def _assign_comnet_extra_values(usage, archetype):
|
def _assign_comnet_extra_values(usage, archetype, occupancy_density):
|
||||||
_occupancy = usage.occupancy
|
_occupancy = usage.occupancy
|
||||||
_occupancy.sensible_radiative_internal_gain = archetype.occupancy.sensible_radiative_internal_gain
|
archetype_density = archetype.occupancy.occupancy_density
|
||||||
_occupancy.latent_internal_gain = archetype.occupancy.latent_internal_gain
|
_occupancy.sensible_radiative_internal_gain = archetype.occupancy.sensible_radiative_internal_gain \
|
||||||
_occupancy.sensible_convective_internal_gain = archetype.occupancy.sensible_convective_internal_gain
|
* occupancy_density / archetype_density
|
||||||
|
_occupancy.latent_internal_gain = archetype.occupancy.latent_internal_gain * occupancy_density / archetype_density
|
||||||
|
_occupancy.sensible_convective_internal_gain = archetype.occupancy.sensible_convective_internal_gain \
|
||||||
|
* occupancy_density / archetype_density
|
||||||
|
|
||||||
@staticmethod
|
@staticmethod
|
||||||
def _calculate_reduced_values_from_extended_library(usage, archetype):
|
def _calculate_reduced_values_from_extended_library(usage, archetype):
|
||||||
|
|