Changes hub to incorporate change of units in infiltration
This commit is contained in:
parent
648548ea2c
commit
d37ce01304
@ -130,11 +130,11 @@ class NrcanCatalog(Catalog):
|
|||||||
# ACH
|
# ACH
|
||||||
mechanical_air_change = space_type['ventilation_air_changes']
|
mechanical_air_change = space_type['ventilation_air_changes']
|
||||||
# cfm/ft2 to m3/m2.s
|
# cfm/ft2 to m3/m2.s
|
||||||
ventilation_rate = space_type['ventilation_per_area'] / (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)
|
ventilation_rate = space_type['ventilation_per_area'] * cte.CUBICFEET_TO_CUBIC_METERS_HOUR
|
||||||
if ventilation_rate == 0:
|
if ventilation_rate == 0:
|
||||||
# cfm/person to m3/m2.s
|
# cfm/person to m3/m2.s
|
||||||
ventilation_rate = space_type['ventilation_per_person'] / (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)\
|
ventilation_rate = space_type['ventilation_per_person'] * cte.CUBICFEET_TO_CUBIC_METERS_HOUR\
|
||||||
/ occupancy_density
|
* occupancy_density
|
||||||
|
|
||||||
lighting_radiative_fraction = space_type['lighting_fraction_radiant']
|
lighting_radiative_fraction = space_type['lighting_fraction_radiant']
|
||||||
lighting_convective_fraction = 0
|
lighting_convective_fraction = 0
|
||||||
|
@ -23,6 +23,7 @@ METERS_TO_FEET = 3.28084
|
|||||||
BTU_H_TO_WATTS = 0.29307107
|
BTU_H_TO_WATTS = 0.29307107
|
||||||
KILO_WATTS_HOUR_TO_JULES = 3600000
|
KILO_WATTS_HOUR_TO_JULES = 3600000
|
||||||
GALLONS_TO_QUBIC_METERS = 0.0037854117954011185
|
GALLONS_TO_QUBIC_METERS = 0.0037854117954011185
|
||||||
|
CUBICFEET_TO_CUBIC_METERS_HOUR=1.699
|
||||||
|
|
||||||
# time
|
# time
|
||||||
SECOND = 'second'
|
SECOND = 'second'
|
||||||
|
@ -83,7 +83,7 @@ class NrcanUsageParameters:
|
|||||||
if archetype.mechanical_air_change > 0:
|
if archetype.mechanical_air_change > 0:
|
||||||
usage.mechanical_air_change = archetype.mechanical_air_change
|
usage.mechanical_air_change = archetype.mechanical_air_change
|
||||||
elif archetype.ventilation_rate > 0:
|
elif archetype.ventilation_rate > 0:
|
||||||
usage.mechanical_air_change = archetype.ventilation_rate / volume_per_area * cte.HOUR_TO_SECONDS
|
usage.mechanical_air_change = archetype.ventilation_rate / volume_per_area
|
||||||
else:
|
else:
|
||||||
usage.mechanical_air_change = 0
|
usage.mechanical_air_change = 0
|
||||||
_occupancy = Occupancy()
|
_occupancy = Occupancy()
|
||||||
|
Loading…
Reference in New Issue
Block a user