Merge remote-tracking branch 'origin/systems_catalog' into systems_catalog
# Conflicts: # hub/data/energy_systems/montreal_custom_systems.xml
This commit is contained in:
commit
dcb5cb4134
|
@ -1,116 +1,282 @@
|
||||||
<catalog lod="1">
|
<catalog lod="1">
|
||||||
|
<generation_equipments>
|
||||||
|
<equipment id="1" type="boiler" fuel_type="gas">
|
||||||
|
<name>Fuel-fired water boiler</name>
|
||||||
|
<heating_efficiency>0.85</heating_efficiency>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="2" type="boiler" fuel_type="electricity">
|
||||||
|
<name>Electric water boiler</name>
|
||||||
|
<heating_efficiency>1</heating_efficiency>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="3" type="furnace" fuel_type="gas">
|
||||||
|
<name>Fuel-fired furnace and fuel boiler for acs</name>
|
||||||
|
<heating_efficiency>0.85</heating_efficiency>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="4" type="furnace" fuel_type="electricity">
|
||||||
|
<name>Electrical furnace and fuel boiler for acs</name>
|
||||||
|
<heating_efficiency>1</heating_efficiency>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="5" type="cooler" fuel_type="electricity">
|
||||||
|
<name>Air cooled DX with external condenser</name>
|
||||||
|
<cooling_efficiency>3.23</cooling_efficiency>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="6" type="electricity generator" fuel_type="renewable">
|
||||||
|
<name>PV system</name>
|
||||||
|
<electrical_efficiency>0.22</electrical_efficiency>
|
||||||
|
</equipment>
|
||||||
|
</generation_equipments>
|
||||||
|
<distribution_equipments>
|
||||||
|
<equipment id="1" type="Water distribution heating">
|
||||||
|
<name>Water distribution heating</name>
|
||||||
|
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">4</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">1</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="2" type="Water distribution cooling">
|
||||||
|
<name>Water distribution cooling</name>
|
||||||
|
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">4</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">1</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="3" type="Central air distribution heating">
|
||||||
|
<name>Central air distribution heating</name>
|
||||||
|
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">13</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="4" type="Central air distribution cooling">
|
||||||
|
<name>Central air distribution cooling</name>
|
||||||
|
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">13</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="5" type="Local air distribution heating">
|
||||||
|
<name>Local air distribution heating</name>
|
||||||
|
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">8</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="6" type="Local air distribution cooling">
|
||||||
|
<name>Local air distribution cooling</name>
|
||||||
|
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">8</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="7" type="Refrigerant distribution">
|
||||||
|
<name>Refrigerant distribution</name>
|
||||||
|
<distribution_heat_losses units="%">1</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">1</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">2</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="8" type="No distribution">
|
||||||
|
<name>No distribution</name>
|
||||||
|
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
||||||
|
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
|
||||||
|
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||||
|
</equipment>
|
||||||
|
</distribution_equipments>
|
||||||
|
<dissipation_equipments>
|
||||||
|
<equipment id="1" type="baseboards">
|
||||||
|
<name>Baseboards</name>
|
||||||
|
<parasitic_consumption>0</parasitic_consumption>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="2" type="fan-coils">
|
||||||
|
<name>fan-coils</name>
|
||||||
|
<parasitic_consumption>2</parasitic_consumption>
|
||||||
|
</equipment>
|
||||||
|
<equipment id="3" type="inductors">
|
||||||
|
<name>inductors</name>
|
||||||
|
<parasitic_consumption>0</parasitic_consumption>
|
||||||
|
</equipment>
|
||||||
|
</dissipation_equipments>
|
||||||
<systems>
|
<systems>
|
||||||
<system id="1" type="boiler" fuel_type="gas">
|
<system id = "1">
|
||||||
<name>Fuel-fired water boiler with baseboards</name>
|
<name>Unitary air conditioner with baseboard heater fuel fired boiler</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>heating</demand>
|
<demand>heating</demand>
|
||||||
<demand>domestic_hot_water</demand>
|
<demand>domestic_hot_water</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<heating_efficiency>0.85</heating_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
<generation_id>1</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>1</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>1</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="2" type="boiler" fuel_type="electricity">
|
<system id = "2">
|
||||||
<name>Electrical resistance water boiler</name>
|
<name>4 pipe fan coils with fuel fired boiler</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>heating</demand>
|
<demand>heating</demand>
|
||||||
<demand>domestic_hot_water</demand>
|
<demand>domestic_hot_water</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<heating_efficiency>1</heating_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
<generation_id>1</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>1</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>2</dissipation_id>
|
||||||
|
</equipments>
|
||||||
|
<storage>false</storage>
|
||||||
|
</system>
|
||||||
|
<system id="3">
|
||||||
|
<name>4 pipe fan coils with electrical resistance water boiler</name>
|
||||||
|
<demands>
|
||||||
|
<demand>heating</demand>
|
||||||
|
<demand>domestic_hot_water</demand>
|
||||||
|
</demands>
|
||||||
|
<equipments>
|
||||||
|
<generation_id>2</generation_id>
|
||||||
|
<distribution_id>1</distribution_id>
|
||||||
|
<dissipation_id>2</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>true</storage>
|
<storage>true</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="3" type="furnace" fuel_type="gas">
|
<system id="4">
|
||||||
<name>Fuel-fired furnace and fuel boiler for acs</name>
|
<name>Single zone packaged rooftop unit with fuel-fired furnace and baseboards and fuel boiler for acs</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>heating</demand>
|
<demand>heating</demand>
|
||||||
<demand>domestic_hot_water</demand>
|
<demand>domestic_hot_water</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<heating_efficiency>0.85</heating_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">25</distribution_heat_losses>
|
<generation_id>3</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>5</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>1</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="4" type="furnace" fuel_type="electricity">
|
<system id="5">
|
||||||
<name>Electrical resistance furnace and electrical boiler for acs</name>
|
<name>Single zone packaged rooftop unit with electrical resistance furnace and baseboards and fuel boiler for acs</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>heating</demand>
|
<demand>heating</demand>
|
||||||
<demand>domestic_hot_water</demand>
|
<demand>domestic_hot_water</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<heating_efficiency>1</heating_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">25</distribution_heat_losses>
|
<generation_id>4</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>5</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>1</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="5" type="baseboard" fuel_type="gas">
|
<system id="6">
|
||||||
<name>Baseboards: hydronic with fuel boiler</name>
|
<name>Single zone make-up air unit with baseboard heating with fuel fired boiler</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>heating</demand>
|
<demand>heating</demand>
|
||||||
<demand>domestic_hot_water</demand>
|
<demand>domestic_hot_water</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<heating_efficiency>0.85</heating_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
<generation_id>1</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>1</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>1</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="6" type="baseboard" fuel_type="electricity">
|
<system id="7">
|
||||||
<name>Electrical baseboards and electrical boiler for acs</name>
|
<name>Single zone make-up air unit with electrical baseboard heating and DHW with resistance</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>heating</demand>
|
<demand>heating</demand>
|
||||||
<demand>domestic_hot_water</demand>
|
<demand>domestic_hot_water</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<heating_efficiency>1</heating_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
<generation_id>2</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>5</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="7" type="cooler" fuel_type="electricity">
|
<system id="8">
|
||||||
<name>Air cooled DX with external condenser</name>
|
<name>Multi-zone built-up system with baseboard heater hydronic with fuel fired boiler</name>
|
||||||
|
<demands>
|
||||||
|
<demand>heating</demand>
|
||||||
|
<demand>domestic_hot_water</demand>
|
||||||
|
</demands>
|
||||||
|
<equipments>
|
||||||
|
<generation_id>2</generation_id>
|
||||||
|
<distribution_id>1</distribution_id>
|
||||||
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
|
<storage>false</storage>
|
||||||
|
</system>
|
||||||
|
<system id="9">
|
||||||
|
<name>Multi-zone built-up system with electrical baseboard heater and electrical hot water</name>
|
||||||
|
<demands>
|
||||||
|
<demand>heating</demand>
|
||||||
|
<demand>domestic_hot_water</demand>
|
||||||
|
</demands>
|
||||||
|
<equipments>
|
||||||
|
<generation_id>2</generation_id>
|
||||||
|
<distribution_id>1</distribution_id>
|
||||||
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
|
<storage>false</storage>
|
||||||
|
</system>
|
||||||
|
<system id="10">
|
||||||
|
<name>Unitary air conditioner air cooled DX with external condenser</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>cooling</demand>
|
<demand>cooling</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<cooling_efficiency>3.23</cooling_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
<generation_id>5</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>6</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="8" type="cooler" fuel_type="electricity">
|
<system id="11">
|
||||||
<name>Water cooled, water chiller</name>
|
<name>4 pipe fan coils with water cooled, water chiller</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>cooling</demand>
|
<demand>cooling</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<cooling_efficiency>3.23</cooling_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
<generation_id>5</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>2</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>2</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="9" type="cooler" fuel_type="electricity">
|
<system id="12">
|
||||||
<name>Air cooled DX</name>
|
<name>Single zone packaged rooftop unit with air cooled DX</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>cooling</demand>
|
<demand>cooling</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<cooling_efficiency>3.23</cooling_efficiency>
|
<equipments>
|
||||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
<generation_id>5</generation_id>
|
||||||
<distribution_consumption_fix_flow units="%">1000000000</distribution_consumption_fix_flow>
|
<distribution_id>6</distribution_id>
|
||||||
<distribution_consumption_variable_flow units="%">1000000000</distribution_consumption_variable_flow>
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>false</storage>
|
<storage>false</storage>
|
||||||
</system>
|
</system>
|
||||||
<system id="10" type="electricity generator" fuel_type="renewable">
|
<system id="13">
|
||||||
|
<name>Single zone make-up air unit with air cooled DX</name>
|
||||||
|
<demands>
|
||||||
|
<demand>cooling</demand>
|
||||||
|
</demands>
|
||||||
|
<equipments>
|
||||||
|
<generation_id>5</generation_id>
|
||||||
|
<distribution_id>6</distribution_id>
|
||||||
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
|
<storage>false</storage>
|
||||||
|
</system>
|
||||||
|
<system id="14">
|
||||||
|
<name>Multi-zone built-up system with water cooled, water chiller</name>
|
||||||
|
<demands>
|
||||||
|
<demand>cooling</demand>
|
||||||
|
</demands>
|
||||||
|
<equipments>
|
||||||
|
<generation_id>5</generation_id>
|
||||||
|
<distribution_id>3</distribution_id>
|
||||||
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
|
<storage>false</storage>
|
||||||
|
</system>
|
||||||
|
<system id="15">
|
||||||
<name>PV system</name>
|
<name>PV system</name>
|
||||||
<demands>
|
<demands>
|
||||||
<demand>electricity</demand>
|
<demand>electricity</demand>
|
||||||
</demands>
|
</demands>
|
||||||
<electrical_efficiency>0.22</electrical_efficiency>
|
<equipments>
|
||||||
|
<generation_id>6</generation_id>
|
||||||
|
<distribution_id>5</distribution_id>
|
||||||
|
<dissipation_id>3</dissipation_id>
|
||||||
|
</equipments>
|
||||||
<storage>true</storage>
|
<storage>true</storage>
|
||||||
</system>
|
</system>
|
||||||
</systems>
|
</systems>
|
||||||
|
@ -125,109 +291,109 @@
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>1</system_id>
|
<system_id>1</system_id>
|
||||||
<system_id>7</system_id>
|
<system_id>7</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 1 electricity">
|
<system_cluster name="system 1 electricity">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>2</system_id>
|
<system_id>1</system_id>
|
||||||
<system_id>7</system_id>
|
<system_id>10</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 1 electricity pv">
|
<system_cluster name="system 1 electricity pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>2</system_id>
|
<system_id>2</system_id>
|
||||||
<system_id>7</system_id>
|
|
||||||
<system_id>10</system_id>
|
<system_id>10</system_id>
|
||||||
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 2 gas">
|
<system_cluster name="system 2 gas">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>1</system_id>
|
<system_id>2</system_id>
|
||||||
<system_id>8</system_id>
|
<system_id>11</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 2 gas pv">
|
<system_cluster name="system 2 gas pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>1</system_id>
|
<system_id>2</system_id>
|
||||||
<system_id>8</system_id>
|
<system_id>11</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 2 electricity">
|
<system_cluster name="system 2 electricity">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>2</system_id>
|
<system_id>3</system_id>
|
||||||
<system_id>8</system_id>
|
<system_id>11</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 2 electricity pv">
|
<system_cluster name="system 2 electricity pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>2</system_id>
|
<system_id>3</system_id>
|
||||||
<system_id>8</system_id>
|
<system_id>11</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 3 and 4 gas">
|
<system_cluster name="system 3 and 4 gas">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>3</system_id>
|
|
||||||
<system_id>4</system_id>
|
<system_id>4</system_id>
|
||||||
|
<system_id>12</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 3 and 4 gas pv">
|
<system_cluster name="system 3 and 4 gas pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>3</system_id>
|
|
||||||
<system_id>4</system_id>
|
<system_id>4</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>12</system_id>
|
||||||
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 3 and 4 electricity">
|
<system_cluster name="system 3 and 4 electricity">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>4</system_id>
|
<system_id>5</system_id>
|
||||||
<system_id>4</system_id>
|
<system_id>12</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 3 and 4 electricity pv">
|
<system_cluster name="system 3 and 4 electricity pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>4</system_id>
|
<system_id>5</system_id>
|
||||||
<system_id>4</system_id>
|
<system_id>12</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 5">
|
<system_cluster name="system 5">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>8</system_id>
|
<system_id>11</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 5 pv">
|
<system_cluster name="system 5 pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>8</system_id>
|
<system_id>11</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 6 gas">
|
<system_cluster name="system 6 gas">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>5</system_id>
|
|
||||||
<system_id>8</system_id>
|
<system_id>8</system_id>
|
||||||
|
<system_id>14</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 6 gas pv">
|
<system_cluster name="system 6 gas pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>5</system_id>
|
|
||||||
<system_id>8</system_id>
|
<system_id>8</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>14</system_id>
|
||||||
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 6 electricity">
|
<system_cluster name="system 6 electricity">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>6</system_id>
|
<system_id>9</system_id>
|
||||||
<system_id>8</system_id>
|
<system_id>14</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
<system_cluster name="system 6 electricity pv">
|
<system_cluster name="system 6 electricity pv">
|
||||||
<systems>
|
<systems>
|
||||||
<system_id>6</system_id>
|
<system_id>9</system_id>
|
||||||
<system_id>8</system_id>
|
<system_id>14</system_id>
|
||||||
<system_id>10</system_id>
|
<system_id>15</system_id>
|
||||||
</systems>
|
</systems>
|
||||||
</system_cluster>
|
</system_cluster>
|
||||||
</system_clusters>
|
</system_clusters>
|
||||||
|
|
Loading…
Reference in New Issue
Block a user