Solving an error in infiltration_area that affected the MEB but not the idf. Now it is solved

This commit is contained in:
ogavalda 2024-10-16 17:18:21 -04:00
parent fbe1701e65
commit f72ccde19e

View File

@ -20,8 +20,8 @@ class ThermalArchetype:
self._indirect_heated_ratio = None self._indirect_heated_ratio = None
self._infiltration_rate_for_ventilation_system_off = None self._infiltration_rate_for_ventilation_system_off = None
self._infiltration_rate_for_ventilation_system_on = None self._infiltration_rate_for_ventilation_system_on = None
self._infiltration_rate_area_for_ventilation_system_off=None self._infiltration_rate_area_for_ventilation_system_off = None
self._infiltration_rate_area_for_ventilation_system_on=None self._infiltration_rate_area_for_ventilation_system_on = None
@property @property
def constructions(self) -> [Construction]: def constructions(self) -> [Construction]:
@ -141,7 +141,7 @@ class ThermalArchetype:
Get infiltration rate for ventilation system off in l/s/m2 Get infiltration rate for ventilation system off in l/s/m2
:return: float :return: float
""" """
return self._infiltration_rate_for_ventilation_system_off return self._infiltration_rate_area_for_ventilation_system_off
@infiltration_rate_area_for_ventilation_system_off.setter @infiltration_rate_area_for_ventilation_system_off.setter
def infiltration_rate_area_for_ventilation_system_off(self, value): def infiltration_rate_area_for_ventilation_system_off(self, value):
@ -149,7 +149,7 @@ class ThermalArchetype:
Set infiltration rate for ventilation system off in l/s/m2 Set infiltration rate for ventilation system off in l/s/m2
:param value: float :param value: float
""" """
self._infiltration_rate_for_ventilation_system_off = value self._infiltration_rate_area_for_ventilation_system_off = value
@property @property
def infiltration_rate_area_for_ventilation_system_on(self): def infiltration_rate_area_for_ventilation_system_on(self):
@ -157,7 +157,7 @@ class ThermalArchetype:
Get infiltration rate for ventilation system on in l/s/m2 Get infiltration rate for ventilation system on in l/s/m2
:return: float :return: float
""" """
return self._infiltration_rate_for_ventilation_system_on return self._infiltration_rate_area_for_ventilation_system_on
@infiltration_rate_area_for_ventilation_system_on.setter @infiltration_rate_area_for_ventilation_system_on.setter
def infiltration_rate_area_for_ventilation_system_on(self, value): def infiltration_rate_area_for_ventilation_system_on(self, value):
@ -165,4 +165,4 @@ class ThermalArchetype:
Set infiltration rate for ventilation system on in l/s/m2 Set infiltration rate for ventilation system on in l/s/m2
:param value: float :param value: float
""" """
self._infiltration_rate_for_ventilation_system_on = value self._infiltration_rate_area_for_ventilation_system_on = value