Compare commits

..

3 Commits

Author SHA1 Message Date
a331dce966 fixed error in logic in _create_generic_systems 2023-10-06 04:14:52 -04:00
3f91da9f45 Merge remote-tracking branch 'origin/energy_system_central_data_model' into energy_system_central_data_model
# Conflicts:
#	hub/imports/energy_systems/montreal_custom_energy_system_parameters.py
2023-10-06 04:13:32 -04:00
f13d7fd860 fixed error in logic in _associate_energy_systems 2023-10-06 04:11:56 -04:00
2 changed files with 40 additions and 41 deletions

View File

@ -75,48 +75,49 @@ class MontrealCustomEnergySystemParameters:
@staticmethod
def _create_generic_systems(archetype, building,
_energy_systems_connection_table, _generic_energy_systems):
building_systems = []
data = [archetype.name, building.name]
_energy_systems_connection_table.loc[len(_energy_systems_connection_table)] = data
for system in archetype.systems:
energy_system = GenericEnergySystem()
_hub_demand_types = []
for demand_type in system.demand_types:
_hub_demand_types.append(Dictionaries().montreal_demand_type_to_hub_energy_demand_type[demand_type])
energy_system.name = system.name
energy_system.demand_types = _hub_demand_types
_generation_system = GenericGenerationSystem()
archetype_generation_equipment = system.generation_systems
_type = system.name
_generation_system.type = Dictionaries().montreal_system_to_hub_energy_generation_system[
_type]
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
_generation_system.fuel_type = _fuel_type
_generation_system.source_types = archetype_generation_equipment.source_medium
_generation_system.heat_efficiency = archetype_generation_equipment.heat_efficiency
_generation_system.cooling_efficiency = archetype_generation_equipment.cooling_efficiency
_generation_system.electricity_efficiency = archetype_generation_equipment.electricity_efficiency
_generation_system.source_temperature = archetype_generation_equipment.source_temperature
_generation_system.source_mass_flow = archetype_generation_equipment.source_mass_flow
_generation_system.storage = archetype_generation_equipment.storage
_generation_system.auxiliary_equipment = None
energy_system.generation_systems = _generation_system
_distribution_system = GenericDistributionSystem()
archetype_distribution_equipment = system.distribution_systems
_distribution_system.type = archetype_distribution_equipment.type
_distribution_system.supply_temperature = archetype_distribution_equipment.supply_temperature
_distribution_system.distribution_consumption_fix_flow = \
archetype_distribution_equipment.distribution_consumption_fix_flow
_distribution_system.distribution_consumption_variable_flow = \
archetype_distribution_equipment.distribution_consumption_variable_flow
_distribution_system.heat_losses = archetype_distribution_equipment.heat_losses
energy_system.distribution_systems = _distribution_system
building_systems.append(energy_system)
if archetype.name not in _generic_energy_systems:
building_systems = []
for system in archetype.systems:
energy_system = GenericEnergySystem()
_hub_demand_types = []
for demand_type in system.demand_types:
_hub_demand_types.append(Dictionaries().montreal_demand_type_to_hub_energy_demand_type[demand_type])
energy_system.name = system.name
energy_system.demand_types = _hub_demand_types
_generation_system = GenericGenerationSystem()
archetype_generation_equipment = system.generation_systems
_type = system.name
_generation_system.type = Dictionaries().montreal_system_to_hub_energy_generation_system[
_type]
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
_generation_system.fuel_type = _fuel_type
_generation_system.source_types = archetype_generation_equipment.source_medium
_generation_system.heat_efficiency = archetype_generation_equipment.heat_efficiency
_generation_system.cooling_efficiency = archetype_generation_equipment.cooling_efficiency
_generation_system.electricity_efficiency = archetype_generation_equipment.electricity_efficiency
_generation_system.source_temperature = archetype_generation_equipment.source_temperature
_generation_system.source_mass_flow = archetype_generation_equipment.source_mass_flow
_generation_system.storage = archetype_generation_equipment.storage
_generation_system.auxiliary_equipment = None
energy_system.generation_systems = _generation_system
_distribution_system = GenericDistributionSystem()
archetype_distribution_equipment = system.distribution_systems
_distribution_system.type = archetype_distribution_equipment.type
_distribution_system.supply_temperature = archetype_distribution_equipment.supply_temperature
_distribution_system.distribution_consumption_fix_flow = \
archetype_distribution_equipment.distribution_consumption_fix_flow
_distribution_system.distribution_consumption_variable_flow = \
archetype_distribution_equipment.distribution_consumption_variable_flow
_distribution_system.heat_losses = archetype_distribution_equipment.heat_losses
energy_system.distribution_systems = _distribution_system
building_systems.append(energy_system)
_generic_energy_systems[archetype.name] = building_systems
return _energy_systems_connection_table, _generic_energy_systems

View File

@ -41,5 +41,3 @@ class TestSystemsCatalog(TestCase):
def test_north_america_systems_catalog(self):
catalog = EnergySystemsCatalogFactory('north_america').catalog
print(catalog.entries())