@ -59,6 +59,7 @@ class Idf:
|
|||||||
_BASEBOARD ='ZONEHVAC:BASEBOARD:CONVECTIVE:ELECTRIC'
|
_BASEBOARD ='ZONEHVAC:BASEBOARD:CONVECTIVE:ELECTRIC'
|
||||||
_AIR_TERMINAL_NO_REHEAT= 'AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT'
|
_AIR_TERMINAL_NO_REHEAT= 'AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT'
|
||||||
_AIR_DISTRIBUTION='ZONEHVAC:AIRDISTRIBUTIONUNIT'
|
_AIR_DISTRIBUTION='ZONEHVAC:AIRDISTRIBUTIONUNIT'
|
||||||
|
_EQUIPMENT_LIST='ZONEHVAC:EQUIPMENTLIST'
|
||||||
|
|
||||||
idf_surfaces = {
|
idf_surfaces = {
|
||||||
cte.WALL: 'wall',
|
cte.WALL: 'wall',
|
||||||
@ -421,13 +422,26 @@ class Idf:
|
|||||||
|
|
||||||
|
|
||||||
def _add_air_distribution_system(self, thermal_zone, zone_name):
|
def _add_air_distribution_system(self, thermal_zone, zone_name):
|
||||||
"""for air_distribution in self._idf.idfobjects[self._AIR_DISTRIBUTION]:
|
for air_distribution in self._idf.idfobjects[self._AIR_DISTRIBUTION]:
|
||||||
if air_distribution.Zone_Name == zone_name:
|
if air_distribution.Zone_Name == zone_name:
|
||||||
return"""
|
return
|
||||||
self._idf.newidfobject(self._AIR_DISTRIBUTION,
|
self._idf.newidfobject(self._AIR_DISTRIBUTION,
|
||||||
Air_Distribution_Outlet_Node_Name='Node 2',
|
Name='ADU Diffuser',
|
||||||
Air_Terminal_Name=f'Diffuser',
|
Air_Distribution_Unit_Outlet_Node_Name='Node 2',
|
||||||
Air_Terminal_Object_Type='AirTerminal:SingleDuct:ConstantVolume:NoReheat')
|
Air_Terminal_Object_Type='AirTerminal:SingleDuct:ConstantVolume:NoReheat',
|
||||||
|
Air_Terminal_Name='Diffuser')
|
||||||
|
def _add_equipment_list_system(self, thermal_zone, zone_name):
|
||||||
|
for air_distribution in self._idf.idfobjects[self._EQUIPMENT_LIST]:
|
||||||
|
if air_distribution.Zone_Name == zone_name:
|
||||||
|
return
|
||||||
|
self._idf.newidfobject(self._EQUIPMENT_LIST,
|
||||||
|
Name=f'{zone_name} Equipment List',
|
||||||
|
Load_Distribution_Scheme='SequentialLoad',
|
||||||
|
Zone_Equipment_1_Object_Type='ZoneHVAC:Baseboard:Convective:Electric',
|
||||||
|
Zone_Equipment_1_Name='Elec Baseboard',
|
||||||
|
Zone_Equipment_1_Heating_or_NoLoad_Sequence='1',
|
||||||
|
Zone_Equipment_2_Object_Type='ZoneHVAC:AirDistributionUnit',
|
||||||
|
Zone_Equipment_2_Name ='ADU Diffuser')
|
||||||
def _add_occupancy(self, thermal_zone, zone_name):
|
def _add_occupancy(self, thermal_zone, zone_name):
|
||||||
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area
|
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area
|
||||||
fraction_radiant = 0
|
fraction_radiant = 0
|
||||||
@ -592,6 +606,7 @@ class Idf:
|
|||||||
self._add_baseboard_system(thermal_zone, building.name)
|
self._add_baseboard_system(thermal_zone, building.name)
|
||||||
self._add_air_terminal_system(thermal_zone, building.name)
|
self._add_air_terminal_system(thermal_zone, building.name)
|
||||||
self._add_air_distribution_system(thermal_zone, building.name)
|
self._add_air_distribution_system(thermal_zone, building.name)
|
||||||
|
self._add_equipment_list_system(thermal_zone, building.name)
|
||||||
self._add_infiltration(thermal_zone, building.name)
|
self._add_infiltration(thermal_zone, building.name)
|
||||||
self._add_ventilation(thermal_zone, building.name)
|
self._add_ventilation(thermal_zone, building.name)
|
||||||
self._add_occupancy(thermal_zone, building.name)
|
self._add_occupancy(thermal_zone, building.name)
|
||||||
|