feature/upgrade_ep_to_23.2.0 #59
|
@ -54,6 +54,14 @@ class Idf:
|
||||||
_SIZING_PERIODS = 'SIZINGPERIOD:DESIGNDAY'
|
_SIZING_PERIODS = 'SIZINGPERIOD:DESIGNDAY'
|
||||||
_LOCATION = 'SITE:LOCATION'
|
_LOCATION = 'SITE:LOCATION'
|
||||||
_SIMPLE = 'Simple'
|
_SIMPLE = 'Simple'
|
||||||
|
_EQUIPMENT_CONNECTIONS = 'ZONEHVAC:EQUIPMENTCONNECTIONS'
|
||||||
|
_NODE_LIST = 'NODELIST'
|
||||||
|
_BASEBOARD = 'ZONEHVAC:BASEBOARD:CONVECTIVE:ELECTRIC'
|
||||||
|
_AIR_TERMINAL_NO_REHEAT = 'AIRTERMINAL:SINGLEDUCT:CONSTANTVOLUME:NOREHEAT'
|
||||||
|
_AIR_DISTRIBUTION = 'ZONEHVAC:AIRDISTRIBUTIONUNIT'
|
||||||
|
_EQUIPMENT_LIST = 'ZONEHVAC:EQUIPMENTLIST'
|
||||||
|
_SIZING_ZONE = 'SIZING:ZONE'
|
||||||
|
_DESIGN_SPECIFICATION_OUTDOOR_AIR = 'DESIGNSPECIFICATION:OUTDOORAIR'
|
||||||
|
|
||||||
idf_surfaces = {
|
idf_surfaces = {
|
||||||
cte.WALL: 'wall',
|
cte.WALL: 'wall',
|
||||||
|
@ -117,7 +125,8 @@ class Idf:
|
||||||
if levels_of_detail.construction is None:
|
if levels_of_detail.construction is None:
|
||||||
raise AttributeError('Level of detail of construction not assigned')
|
raise AttributeError('Level of detail of construction not assigned')
|
||||||
if levels_of_detail.construction < 2:
|
if levels_of_detail.construction < 2:
|
||||||
raise AttributeError(f'Level of detail of construction = {levels_of_detail.construction}. Required minimum level 2')
|
raise AttributeError(
|
||||||
|
f'Level of detail of construction = {levels_of_detail.construction}. Required minimum level 2')
|
||||||
if levels_of_detail.usage is None:
|
if levels_of_detail.usage is None:
|
||||||
raise AttributeError('Level of detail of usage not assigned')
|
raise AttributeError('Level of detail of usage not assigned')
|
||||||
if levels_of_detail.usage < 2:
|
if levels_of_detail.usage < 2:
|
||||||
|
@ -381,16 +390,80 @@ class Idf:
|
||||||
)
|
)
|
||||||
|
|
||||||
def _add_heating_system(self, thermal_zone, zone_name):
|
def _add_heating_system(self, thermal_zone, zone_name):
|
||||||
for air_system in self._idf.idfobjects[self._IDEAL_LOAD_AIR_SYSTEM]:
|
for air_system in self._idf.idfobjects[self._EQUIPMENT_CONNECTIONS]:
|
||||||
if air_system.Zone_Name == zone_name:
|
if air_system.Zone_Name == zone_name:
|
||||||
return
|
return
|
||||||
thermostat = self._add_thermostat(thermal_zone)
|
thermostat = self._add_thermostat(thermal_zone)
|
||||||
self._idf.newidfobject(self._IDEAL_LOAD_AIR_SYSTEM,
|
self._idf.newidfobject(self._EQUIPMENT_CONNECTIONS,
|
||||||
Zone_Name=zone_name,
|
Zone_Name=zone_name,
|
||||||
System_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
Zone_Conditioning_Equipment_List_Name=f'{zone_name} Equipment List',
|
||||||
Heating_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
Zone_Air_Inlet_Node_or_NodeList_Name=f'{zone_name} Inlet Node List',
|
||||||
Cooling_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
Zone_Air_Node_Name=f'Node 1',
|
||||||
Template_Thermostat_Name=thermostat.Name)
|
Zone_Return_Air_Node_or_NodeList_Name=f'{zone_name} Return Node List')
|
||||||
|
|
||||||
|
def _add_nodelist_system(self, thermal_zone, zone_name):
|
||||||
|
self._idf.newidfobject(self._NODE_LIST,
|
||||||
|
Name=f'{zone_name} Inlet Node List',
|
||||||
|
Node_1_Name='Node 2')
|
||||||
|
self._idf.newidfobject(self._NODE_LIST,
|
||||||
|
Name=f'{zone_name} Return Node List',
|
||||||
|
Node_1_Name='Node 3')
|
||||||
|
|
||||||
|
def _add_baseboard_system(self, thermal_zone, zone_name):
|
||||||
|
for baseboard in self._idf.idfobjects[self._BASEBOARD]:
|
||||||
|
if baseboard.Zone_Name == zone_name:
|
||||||
|
return
|
||||||
|
self._idf.newidfobject(self._BASEBOARD, Name=f'Elec Baseboard',Availability_Schedule_Name='HVAC AVAIL')
|
||||||
|
|
||||||
|
def _add_air_terminal_system(self, thermal_zone, zone_name):
|
||||||
|
"""for air_terminal in self._idf.idfobjects[self._AIR_TERMINAL_NO_REHEAT]:
|
||||||
|
if air_terminal.Zone_Name == zone_name:
|
||||||
|
return"""
|
||||||
|
self._idf.newidfobject(self._AIR_TERMINAL_NO_REHEAT, Name=f'Diffuser',
|
||||||
|
Availability_Schedule_Name='HVAC AVAIL',
|
||||||
|
Air_Inlet_Node_Name='Node 4',
|
||||||
|
Air_Outlet_Node_Name='Node 2',
|
||||||
|
Maximum_Air_Flow_Rate='AutoSize')
|
||||||
|
|
||||||
|
def _add_air_distribution_system(self, thermal_zone, zone_name):
|
||||||
|
for air_distribution in self._idf.idfobjects[self._AIR_DISTRIBUTION]:
|
||||||
|
if air_distribution.Zone_Name == zone_name:
|
||||||
|
return
|
||||||
|
self._idf.newidfobject(self._AIR_DISTRIBUTION,
|
||||||
|
Name='ADU Diffuser',
|
||||||
|
Air_Distribution_Unit_Outlet_Node_Name='Node 2',
|
||||||
|
Air_Terminal_Object_Type='AirTerminal:SingleDuct:ConstantVolume:NoReheat',
|
||||||
|
Air_Terminal_Name='Diffuser')
|
||||||
|
|
||||||
|
def _add_equipment_list_system(self, thermal_zone, zone_name):
|
||||||
|
for air_distribution in self._idf.idfobjects[self._EQUIPMENT_LIST]:
|
||||||
|
if air_distribution.Zone_Name == zone_name:
|
||||||
|
return
|
||||||
|
self._idf.newidfobject(self._EQUIPMENT_LIST,
|
||||||
|
Name=f'{zone_name} Equipment List',
|
||||||
|
Load_Distribution_Scheme='SequentialLoad',
|
||||||
|
Zone_Equipment_1_Object_Type='ZoneHVAC:Baseboard:Convective:Electric',
|
||||||
|
Zone_Equipment_1_Name='Elec Baseboard',
|
||||||
|
Zone_Equipment_1_Cooling_Sequence='1',
|
||||||
|
Zone_Equipment_1_Heating_or_NoLoad_Sequence='1',
|
||||||
|
Zone_Equipment_2_Object_Type='ZoneHVAC:AirDistributionUnit',
|
||||||
|
Zone_Equipment_2_Name='ADU Diffuser',
|
||||||
|
Zone_Equipment_2_Cooling_Sequence='2',
|
||||||
|
Zone_Equipment_2_Heating_or_NoLoad_Sequence='2'
|
||||||
|
)
|
||||||
|
|
||||||
|
def _add_sizing_zone(self, thermal_zone, zone_name):
|
||||||
|
koa=self._idf.newidfobject(self._SIZING_ZONE,
|
||||||
|
Zone_or_ZoneList_Name=f'{zone_name}',
|
||||||
|
Zone_Cooling_Design_Supply_Air_Humidity_Ratio='0.0085',
|
||||||
|
Zone_Heating_Design_Supply_Air_Humidity_Ratio='0.008'
|
||||||
|
)
|
||||||
|
|
||||||
|
def _add_outdoor_air_design_specification(self, thermal_zone, zone_name):
|
||||||
|
self._idf.newidfobject(self._DESIGN_SPECIFICATION_OUTDOOR_AIR,
|
||||||
|
Name='MidriseApartment Apartment Ventilation',
|
||||||
|
Outdoor_Air_Method='Sum',
|
||||||
|
Outdoor_Air_Flow_per_Person='0.0169901079552')
|
||||||
|
|
||||||
def _add_occupancy(self, thermal_zone, zone_name):
|
def _add_occupancy(self, thermal_zone, zone_name):
|
||||||
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area
|
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area
|
||||||
|
@ -553,10 +626,6 @@ class Idf:
|
||||||
self._add_zone(thermal_zone, building.name)
|
self._add_zone(thermal_zone, building.name)
|
||||||
self._add_heating_system(thermal_zone, building.name)
|
self._add_heating_system(thermal_zone, building.name)
|
||||||
self._add_infiltration(thermal_zone, building.name)
|
self._add_infiltration(thermal_zone, building.name)
|
||||||
self._add_ventilation(thermal_zone, building.name)
|
|
||||||
self._add_occupancy(thermal_zone, building.name)
|
|
||||||
self._add_lighting(thermal_zone, building.name)
|
|
||||||
self._add_appliances(thermal_zone, building.name)
|
|
||||||
self._add_dhw(thermal_zone, building.name)
|
self._add_dhw(thermal_zone, building.name)
|
||||||
if self._export_type == "Surfaces":
|
if self._export_type == "Surfaces":
|
||||||
if building.name in self._target_buildings or building.name in self._adjacent_buildings:
|
if building.name in self._target_buildings or building.name in self._adjacent_buildings:
|
||||||
|
@ -586,7 +655,6 @@ class Idf:
|
||||||
Variable_Name="Water Use Equipment Heating Rate",
|
Variable_Name="Water Use Equipment Heating Rate",
|
||||||
Reporting_Frequency="Hourly",
|
Reporting_Frequency="Hourly",
|
||||||
)
|
)
|
||||||
|
|
||||||
# post-process to erase windows associated to adiabatic walls
|
# post-process to erase windows associated to adiabatic walls
|
||||||
windows_list = []
|
windows_list = []
|
||||||
for window in self._idf.idfobjects[self._WINDOW]:
|
for window in self._idf.idfobjects[self._WINDOW]:
|
||||||
|
@ -598,7 +666,6 @@ class Idf:
|
||||||
windows_list.append(window)
|
windows_list.append(window)
|
||||||
for window in windows_list:
|
for window in windows_list:
|
||||||
self._idf.removeidfobject(window)
|
self._idf.removeidfobject(window)
|
||||||
|
|
||||||
self._idf.saveas(str(self._output_file))
|
self._idf.saveas(str(self._output_file))
|
||||||
return self._idf
|
return self._idf
|
||||||
|
|
||||||
|
|
103532
hub/exports/building_energy/idf_files/Energy+9.5.idd
Normal file
103532
hub/exports/building_energy/idf_files/Energy+9.5.idd
Normal file
File diff suppressed because it is too large
Load Diff
|
@ -13,7 +13,7 @@
|
||||||
! HVAC: None.
|
! HVAC: None.
|
||||||
!
|
!
|
||||||
|
|
||||||
Version,23.2;
|
Version,24.1;
|
||||||
|
|
||||||
Timestep,4;
|
Timestep,4;
|
||||||
|
|
||||||
|
@ -122,8 +122,8 @@
|
||||||
No, !- Do Zone Sizing Calculation
|
No, !- Do Zone Sizing Calculation
|
||||||
No, !- Do System Sizing Calculation
|
No, !- Do System Sizing Calculation
|
||||||
No, !- Do Plant Sizing Calculation
|
No, !- Do Plant Sizing Calculation
|
||||||
No, !- Run Simulation for Sizing Periods
|
Yes, !- Run Simulation for Sizing Periods
|
||||||
Yes, !- Run Simulation for Weather File Run Periods
|
No, !- Run Simulation for Weather File Run Periods
|
||||||
No, !- Do HVAC Sizing Simulation for Sizing Periods
|
No, !- Do HVAC Sizing Simulation for Sizing Periods
|
||||||
1; !- Maximum Number of HVAC Sizing Simulation Passes
|
1; !- Maximum Number of HVAC Sizing Simulation Passes
|
||||||
|
|
||||||
|
|
157
hub/exports/building_energy/idf_files/Minimal9.5.idf
Normal file
157
hub/exports/building_energy/idf_files/Minimal9.5.idf
Normal file
|
@ -0,0 +1,157 @@
|
||||||
|
! Minimal.idf
|
||||||
|
! Basic file description: This is a minimal configuration necessary to run.
|
||||||
|
! Highlights: Illustrates minimal items necessary to perform run.
|
||||||
|
! BUILDING, SURFACEGEOMETRY, LOCATION and DESIGNDAY (or RUNPERIOD) are the absolute minimal required input objects.
|
||||||
|
! TIME STEP IN HOUR is included so as to not get warning error.
|
||||||
|
! Including two design days, Run Control object and RunPeriod to facilitate use.
|
||||||
|
! Although not incredibly useful, this could be used as a weather/solar calculator.
|
||||||
|
! Simulation Location/Run: Denver is included. Any could be used.
|
||||||
|
! Building: None.
|
||||||
|
!
|
||||||
|
! Internal gains description: None.
|
||||||
|
!
|
||||||
|
! HVAC: None.
|
||||||
|
!
|
||||||
|
|
||||||
|
Version,9.5;
|
||||||
|
|
||||||
|
Timestep,4;
|
||||||
|
|
||||||
|
Building,
|
||||||
|
None, !- Name
|
||||||
|
0.0000000E+00, !- North Axis {deg}
|
||||||
|
Suburbs, !- Terrain
|
||||||
|
0.04, !- Loads Convergence Tolerance Value {W}
|
||||||
|
0.40, !- Temperature Convergence Tolerance Value {deltaC}
|
||||||
|
FullInteriorAndExterior, !- Solar Distribution
|
||||||
|
25, !- Maximum Number of Warmup Days
|
||||||
|
6; !- Minimum Number of Warmup Days
|
||||||
|
|
||||||
|
GlobalGeometryRules,
|
||||||
|
UpperLeftCorner, !- Starting Vertex Position
|
||||||
|
CounterClockWise, !- Vertex Entry Direction
|
||||||
|
World; !- Coordinate System
|
||||||
|
|
||||||
|
Site:Location,
|
||||||
|
DENVER_STAPLETON_CO_USA_WMO_724690, !- Name
|
||||||
|
39.77, !- Latitude {deg}
|
||||||
|
-104.87, !- Longitude {deg}
|
||||||
|
-7.00, !- Time Zone {hr}
|
||||||
|
1611.00; !- Elevation {m}
|
||||||
|
|
||||||
|
! DENVER_STAPLETON_CO_USA Annual Heating Design Conditions Wind Speed=2.3m/s Wind Dir=180
|
||||||
|
! Coldest Month=December
|
||||||
|
! DENVER_STAPLETON_CO_USA Annual Heating 99.6%, MaxDB=-20°C
|
||||||
|
|
||||||
|
SizingPeriod:DesignDay,
|
||||||
|
DENVER_STAPLETON Ann Htg 99.6% Condns DB, !- Name
|
||||||
|
12, !- Month
|
||||||
|
21, !- Day of Month
|
||||||
|
WinterDesignDay, !- Day Type
|
||||||
|
-20, !- Maximum Dry-Bulb Temperature {C}
|
||||||
|
0.0, !- Daily Dry-Bulb Temperature Range {deltaC}
|
||||||
|
, !- Dry-Bulb Temperature Range Modifier Type
|
||||||
|
, !- Dry-Bulb Temperature Range Modifier Day Schedule Name
|
||||||
|
Wetbulb, !- Humidity Condition Type
|
||||||
|
-20, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
|
||||||
|
, !- Humidity Condition Day Schedule Name
|
||||||
|
, !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
|
||||||
|
, !- Enthalpy at Maximum Dry-Bulb {J/kg}
|
||||||
|
, !- Daily Wet-Bulb Temperature Range {deltaC}
|
||||||
|
83411., !- Barometric Pressure {Pa}
|
||||||
|
2.3, !- Wind Speed {m/s}
|
||||||
|
180, !- Wind Direction {deg}
|
||||||
|
No, !- Rain Indicator
|
||||||
|
No, !- Snow Indicator
|
||||||
|
No, !- Daylight Saving Time Indicator
|
||||||
|
ASHRAEClearSky, !- Solar Model Indicator
|
||||||
|
, !- Beam Solar Day Schedule Name
|
||||||
|
, !- Diffuse Solar Day Schedule Name
|
||||||
|
, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless}
|
||||||
|
, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless}
|
||||||
|
0.00; !- Sky Clearness
|
||||||
|
|
||||||
|
! DENVER_STAPLETON Annual Cooling Design Conditions Wind Speed=4m/s Wind Dir=120
|
||||||
|
! Hottest Month=July
|
||||||
|
! DENVER_STAPLETON_CO_USA Annual Cooling (DB=>MWB) .4%, MaxDB=34.1°C MWB=15.8°C
|
||||||
|
|
||||||
|
SizingPeriod:DesignDay,
|
||||||
|
DENVER_STAPLETON Ann Clg .4% Condns DB=>MWB, !- Name
|
||||||
|
7, !- Month
|
||||||
|
21, !- Day of Month
|
||||||
|
SummerDesignDay, !- Day Type
|
||||||
|
34.1, !- Maximum Dry-Bulb Temperature {C}
|
||||||
|
15.2, !- Daily Dry-Bulb Temperature Range {deltaC}
|
||||||
|
, !- Dry-Bulb Temperature Range Modifier Type
|
||||||
|
, !- Dry-Bulb Temperature Range Modifier Day Schedule Name
|
||||||
|
Wetbulb, !- Humidity Condition Type
|
||||||
|
15.8, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
|
||||||
|
, !- Humidity Condition Day Schedule Name
|
||||||
|
, !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
|
||||||
|
, !- Enthalpy at Maximum Dry-Bulb {J/kg}
|
||||||
|
, !- Daily Wet-Bulb Temperature Range {deltaC}
|
||||||
|
83411., !- Barometric Pressure {Pa}
|
||||||
|
4, !- Wind Speed {m/s}
|
||||||
|
120, !- Wind Direction {deg}
|
||||||
|
No, !- Rain Indicator
|
||||||
|
No, !- Snow Indicator
|
||||||
|
No, !- Daylight Saving Time Indicator
|
||||||
|
ASHRAEClearSky, !- Solar Model Indicator
|
||||||
|
, !- Beam Solar Day Schedule Name
|
||||||
|
, !- Diffuse Solar Day Schedule Name
|
||||||
|
, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless}
|
||||||
|
, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless}
|
||||||
|
1.00; !- Sky Clearness
|
||||||
|
|
||||||
|
RunPeriod,
|
||||||
|
Run Period 1, !- Name
|
||||||
|
1, !- Begin Month
|
||||||
|
1, !- Begin Day of Month
|
||||||
|
, !- Begin Year
|
||||||
|
12, !- End Month
|
||||||
|
31, !- End Day of Month
|
||||||
|
, !- End Year
|
||||||
|
Tuesday, !- Day of Week for Start Day
|
||||||
|
Yes, !- Use Weather File Holidays and Special Days
|
||||||
|
Yes, !- Use Weather File Daylight Saving Period
|
||||||
|
No, !- Apply Weekend Holiday Rule
|
||||||
|
Yes, !- Use Weather File Rain Indicators
|
||||||
|
Yes; !- Use Weather File Snow Indicators
|
||||||
|
|
||||||
|
SimulationControl,
|
||||||
|
No, !- Do Zone Sizing Calculation
|
||||||
|
No, !- Do System Sizing Calculation
|
||||||
|
No, !- Do Plant Sizing Calculation
|
||||||
|
No, !- Run Simulation for Sizing Periods
|
||||||
|
Yes, !- Run Simulation for Weather File Run Periods
|
||||||
|
No, !- Do HVAC Sizing Simulation for Sizing Periods
|
||||||
|
1; !- Maximum Number of HVAC Sizing Simulation Passes
|
||||||
|
|
||||||
|
Output:Table:SummaryReports, AnnualBuildingUtilityPerformanceSummary,
|
||||||
|
DemandEndUseComponentsSummary,
|
||||||
|
SensibleHeatGainSummary,
|
||||||
|
InputVerificationandResultsSummary,
|
||||||
|
AdaptiveComfortSummary,
|
||||||
|
Standard62.1Summary,
|
||||||
|
ClimaticDataSummary,
|
||||||
|
EquipmentSummary,
|
||||||
|
EnvelopeSummary,
|
||||||
|
LightingSummary,
|
||||||
|
HVACSizingSummary,
|
||||||
|
SystemSummary,
|
||||||
|
ComponentSizingSummary,
|
||||||
|
OutdoorAirSummary,
|
||||||
|
ObjectCountSummary,
|
||||||
|
EndUseEnergyConsumptionOtherFuelsMonthly,
|
||||||
|
PeakEnergyEndUseOtherFuelsMonthly;
|
||||||
|
|
||||||
|
|
||||||
|
OutputControl:Table:Style, CommaAndHTML,JtoKWH;
|
||||||
|
|
||||||
|
Output:Meter,DISTRICTHEATING:Facility,hourly;
|
||||||
|
Output:Meter,DISTRICTCOOLING:Facility,hourly;
|
||||||
|
Output:Meter,InteriorEquipment:Electricity,hourly;
|
||||||
|
Output:Meter,InteriorLights:Electricity,hourly;
|
||||||
|
|
||||||
|
OutputControl:IlluminanceMap:Style,
|
||||||
|
Comma; !- Column separator
|
142
texttest
Normal file
142
texttest
Normal file
|
@ -0,0 +1,142 @@
|
||||||
|
ZoneControl:Thermostat,
|
||||||
|
Room_180_7ad8616b Thermostat, !- Name
|
||||||
|
Room_180_7ad8616b, !- Zone or ZoneList Name
|
||||||
|
Room_180_7ad8616b Thermostat Schedule, !- Control Type Schedule Name
|
||||||
|
ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
|
||||||
|
LargeOffice Building_Setpoint 26, !- Control 1 Name
|
||||||
|
, !- Control 2 Object Type
|
||||||
|
, !- Control 2 Name
|
||||||
|
, !- Control 3 Object Type
|
||||||
|
, !- Control 3 Name
|
||||||
|
, !- Control 4 Object Type
|
||||||
|
, !- Control 4 Name
|
||||||
|
0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
|
||||||
|
|
||||||
|
Schedule:Compact,
|
||||||
|
Room_180_7ad8616b Thermostat Schedule, !- Name
|
||||||
|
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Schedule Type Limits Name
|
||||||
|
Through: 12/31, !- Field 1
|
||||||
|
For: AllDays, !- Field 2
|
||||||
|
Until: 24:00, !- Field 3
|
||||||
|
4; !- Field 4
|
||||||
|
|
||||||
|
ScheduleTypeLimits,
|
||||||
|
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Name
|
||||||
|
0, !- Lower Limit Value {BasedOnField A3}
|
||||||
|
4, !- Upper Limit Value {BasedOnField A3}
|
||||||
|
DISCRETE; !- Numeric Type
|
||||||
|
|
||||||
|
ThermostatSetpoint:DualSetpoint,
|
||||||
|
LargeOffice Building_Setpoint 26, !- Name
|
||||||
|
LargeOffice Building_Setpoint_HtgSetp Schedule, !- Heating Setpoint Temperature Schedule Name
|
||||||
|
LargeOffice Building_Setpoint_ClgSetp Schedule; !- Cooling Setpoint Temperature Schedule Name
|
||||||
|
|
||||||
|
ZoneHVAC:EquipmentConnections,
|
||||||
|
Room_180_7ad8616b, !- Zone Name
|
||||||
|
Room_180_7ad8616b Equipment List, !- Zone Conditioning Equipment List Name
|
||||||
|
Room_180_7ad8616b Inlet Node List, !- Zone Air Inlet Node or NodeList Name
|
||||||
|
, !- Zone Air Exhaust Node or NodeList Name
|
||||||
|
Node 27, !- Zone Air Node Name
|
||||||
|
Room_180_7ad8616b Return Node List; !- Zone Return Air Node or NodeList Name
|
||||||
|
|
||||||
|
NodeList,
|
||||||
|
Room_180_7ad8616b Inlet Node List, !- Name
|
||||||
|
Node 305; !- Node Name 1
|
||||||
|
|
||||||
|
NodeList,
|
||||||
|
Room_180_7ad8616b Return Node List, !- Name
|
||||||
|
Node 308; !- Node Name 1
|
||||||
|
|
||||||
|
ZoneHVAC:Baseboard:Convective:Electric,
|
||||||
|
Elec Baseboard 1, !- Name
|
||||||
|
Always On Discrete hvac_library, !- Availability Schedule Name
|
||||||
|
, !- Heating Design Capacity Method
|
||||||
|
Autosize, !- Heating Design Capacity {W}
|
||||||
|
, !- Heating Design Capacity Per Floor Area {W/m2}
|
||||||
|
, !- Fraction of Autosized Heating Design Capacity
|
||||||
|
1; !- Efficiency
|
||||||
|
|
||||||
|
AirTerminal:SingleDuct:ConstantVolume:NoReheat,
|
||||||
|
Diffuser 21, !- Name
|
||||||
|
Always On Discrete hvac_library, !- Availability Schedule Name
|
||||||
|
Node 307, !- Air Inlet Node Name
|
||||||
|
Node 305, !- Air Outlet Node Name
|
||||||
|
AutoSize; !- Maximum Air Flow Rate {m3/s}
|
||||||
|
|
||||||
|
ZoneHVAC:AirDistributionUnit,
|
||||||
|
ADU Diffuser 21, !- Name
|
||||||
|
Node 305, !- Air Distribution Unit Outlet Node Name
|
||||||
|
AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type
|
||||||
|
Diffuser 21; !- Air Terminal Name
|
||||||
|
|
||||||
|
ZoneHVAC:EquipmentList,
|
||||||
|
Room_180_7ad8616b Equipment List, !- Name
|
||||||
|
SequentialLoad, !- Load Distribution Scheme
|
||||||
|
ZoneHVAC:Baseboard:Convective:Electric, !- Zone Equipment Object Type 1
|
||||||
|
Elec Baseboard 1, !- Zone Equipment Name 1
|
||||||
|
1, !- Zone Equipment Cooling Sequence 1
|
||||||
|
1, !- Zone Equipment Heating or No-Load Sequence 1
|
||||||
|
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 1
|
||||||
|
, !- Zone Equipment Sequential Heating Fraction Schedule Name 1
|
||||||
|
ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type 2
|
||||||
|
ADU Diffuser 21, !- Zone Equipment Name 2
|
||||||
|
2, !- Zone Equipment Cooling Sequence 2
|
||||||
|
2, !- Zone Equipment Heating or No-Load Sequence 2
|
||||||
|
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 2
|
||||||
|
; !- Zone Equipment Sequential Heating Fraction Schedule Name 2
|
||||||
|
|
||||||
|
Sizing:Zone,
|
||||||
|
Room_180_7ad8616b, !- Zone or ZoneList Name
|
||||||
|
SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
|
||||||
|
14, !- Zone Cooling Design Supply Air Temperature {C}
|
||||||
|
11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
|
||||||
|
SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
|
||||||
|
40, !- Zone Heating Design Supply Air Temperature {C}
|
||||||
|
11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
|
||||||
|
0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||||
|
0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||||
|
Room_180_7ad8616b DSOA Space List, !- Design Specification Outdoor Air Object Name
|
||||||
|
, !- Zone Heating Sizing Factor
|
||||||
|
, !- Zone Cooling Sizing Factor
|
||||||
|
DesignDay, !- Cooling Design Air Flow Method
|
||||||
|
0, !- Cooling Design Air Flow Rate {m3/s}
|
||||||
|
0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
|
||||||
|
0, !- Cooling Minimum Air Flow {m3/s}
|
||||||
|
0, !- Cooling Minimum Air Flow Fraction
|
||||||
|
DesignDay, !- Heating Design Air Flow Method
|
||||||
|
0, !- Heating Design Air Flow Rate {m3/s}
|
||||||
|
0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
|
||||||
|
0.1415762, !- Heating Maximum Air Flow {m3/s}
|
||||||
|
0.3, !- Heating Maximum Air Flow Fraction
|
||||||
|
, !- Design Specification Zone Air Distribution Object Name
|
||||||
|
No, !- Account for Dedicated Outdoor Air System
|
||||||
|
, !- Dedicated Outdoor Air System Control Strategy
|
||||||
|
, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C}
|
||||||
|
, !- Dedicated Outdoor Air High Setpoint Temperature for Design {C}
|
||||||
|
Sensible Load Only No Latent Load, !- Zone Load Sizing Method
|
||||||
|
HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method
|
||||||
|
, !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||||
|
0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
|
||||||
|
HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method
|
||||||
|
, !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||||
|
0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
|
||||||
|
|
||||||
|
DesignSpecification:OutdoorAir:SpaceList,
|
||||||
|
Room_180_7ad8616b DSOA Space List, !- Name
|
||||||
|
Room_180_7ad8616b_Space, !- Space Name 1
|
||||||
|
MidriseApartment Apartment Ventilation; !- Space Design Specification Outdoor Air Object Name 1
|
||||||
|
|
||||||
|
Zone,
|
||||||
|
Room_181_3a411b5d, !- Name
|
||||||
|
, !- Direction of Relative North {deg}
|
||||||
|
0, !- X Origin {m}
|
||||||
|
0, !- Y Origin {m}
|
||||||
|
0, !- Z Origin {m}
|
||||||
|
, !- Type
|
||||||
|
1, !- Multiplier
|
||||||
|
4, !- Ceiling Height {m}
|
||||||
|
291.62935408288, !- Volume {m3}
|
||||||
|
, !- Floor Area {m2}
|
||||||
|
, !- Zone Inside Convection Algorithm
|
||||||
|
, !- Zone Outside Convection Algorithm
|
||||||
|
Yes; !- Part of Total Floor Area
|