!The DOE Prototype Building Models were developed by Pacific Northwest National Laboratory (PNNL), under contract with the U.S. !Department of Energy (DOE). These building models were derived from DOE's Commercial Reference Building Models with modifications !based on input from the ASHRAE Standard 90.1 committee, the Advanced Energy Design Guide series, and building industry experts. The !prototypes models were developed to quantify energy saving impacts from newly published editions of ASHRAE Standard 90.1, 189.1, IECC, !and other energy codes and standards. The basic building descriptions can be found in the Scorecards posted at www.energycodes.gov !website. The recommended citation of the prototype models is ! !DOE and PNNL. 2020. Commercial Prototype Building Models, Richland, WA, Pacific Northwest National Laboratory. Available at https://www.energycodes.gov/development/commercial/prototype_models. ! !Detailed descriptions of the prototype model development and addenda modeling strategies can be found in the following reports: !DOE, 2020. Preliminary Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2019. Report prepared by Zhang, J., M. Rosenberg, J. !Lerond, Y. Xie, Nambia, C., Y. Chen, R. Hart, M. Halverson, D. Maddox, and S. Goel, Richland, WA, Pacific Northwest National Laboratory. ! !Zhang, J., Y. Chen, Y. Xie, M. Rosenberg, R. Hart. Energy and Energy Cost Savings Analysis of the 2018 IECC for Commercial Buildings. !2018. PNNL-28125. Richland, WA: Pacific Northwest National Laboratory. ! !DOE. 2017. Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016. Prepared by Athalye, R.A, M.A. Halverson, M.I. Rosenberg, B. Liu, !J. Zhang, R. Hart, V.V. Mendon, S. Goel, Y. Chen, Y. Xie, and M. Zhao, Richland, WA, Pacific Northwest National Laboratory. https://www.energycodes.gov/sites/default/files/documents/02202018_Standard_90.1-2016_Determination_TSD.pdf. ! !Zhang, J., Y. Xie, R.A. Athalye, J. Zhuge, M. Rosenberg, R. Hart, and B. Liu. Energy and Energy Cost Savings Analysis of the 2015 IECC !for Commercial Buildings. 2015. PNNL-24269 Rev. 1. Richland, WA: Pacific Northwest National !Laboratory. https://www.energycodes.gov/sites/default/files/documents/2015_IECC_Commercial_Analysis.pdf. ! !Halverson M.A., M.I. Rosenberg, W. Wang, J. Zhang, V.V. Mendon, R.A. Athalye, Y. Xie, R. Hart, S. Goel, 2014. ANSI/ASHRAE/IES Standard !90.1-2013 Determination of Energy Savings: Quantitative Analysis, PNNL-23479. Richland, WA: Pacific Northwest National Laboratory. https://www.energycodes.gov/sites/default/files/documents/901-2013_finalCommercialDeterminationQuantitativeAnalysis_TSD_0.pdf. ! !Goel S., R.A. Athalye, W. Wang, J. Zhang, M.I. Rosenberg, Y. Xie, and R. Hart, et al. 2014. Enhancements to ASHRAE Standard 90.1 !Prototype Building Models. PNNL-23269. Richland, WA: Pacific Northwest National Laboratory. https://www.pnnl.gov/main/publications/external/technical_reports/PNNL-23269.pdf. ! !Zhang J., R.A. Athalye, R. Hart, M.I. Rosenberg, Y. Xie, S. Goel, and V.V. Mendon, et al. 2013. Energy and Energy Cost Savings Analysis !of the IECC for Commercial Buildings. PNNL-22760. Richland, WA: Pacific Northwest National Laboratory. http://www.pnnl.gov/main/publications/external/technical_reports/PNNL-22760.pdf. ! !Thornton B.A., M.I. Rosenberg, E.E. Richman, W. Wang, Y. Xie, J. Zhang, H. Cho, VV Mendon, R.A. Athalye, and B. Liu. 2011. Achieving !the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010. PNNL-20405. Richland, WA: Pacific Northwest National !Laboratory. https://www.energycodes.gov/sites/default/files/documents/BECP_Energy_Cost_Savings_STD2010_May2011_v00.pdf. ! ! ! WeatherFile: USA_MN_Rochester.Intl.AP.726440_TMY3.epw ! BEGIN ECONOMIZER MAP ! NOTE: no economizer map is created for this prototype due to water cooling ! END ECONOMIZER MAP ! GPARM parameters as input: ! Case = ASHRAE901_OfficeLarge_STD2019_Rochester ! SelectedCase = ! basement_tempt = Zone6A_nonres_R10_OfficeLarge_Rochester_STD2016_out.idf ! avg_oa_tempt_ip = 43.475 ! maxdiff_oa_tempt_ip = 60.3 ! ext_wall_type = MassWall ! nonres_ext_wall_ufactor = 0.45426104 ! roof_type = MetalDeckRoof ! nonres_roof_ufactor = 0.181704416 ! roof_solar_absorp = 0.7 ! roof_emissivity = 0.9 ! nonres_window = ! sidelighting_control = yes_AY ! LPD_office = 6.888902667 ! exterior_lights_watts = 0 ! exterior_lights_watts_a = 12979.2 ! exterior_lights_watts_b = 968 ! economizer = DifferentialDryBulb ! skip_economizer_control = Yes ! damper_sche = MinOA_MotorizedDamper_Sched ! cc_sa_humidity = 0.0085 ! condenser_pump_head = 148556.6249 ! chilledwater_pump_head = 44761.27683 ! chilledwater_pump_secondary_head = 134283.8305 ! avg_oa_tempt = 6.375 ! maxdiff_oa_tempt = 33.5 ! infil = 0.00056896 ! oa_flow_per_area = 0.000431773 ! SAT_reset_switch = Yes ! SAT_reset_T = 15.6 ! CAV_bas_ERV = No ! economizer_lockout = LockoutWithHeating ! eco_max_temp_limit = na ! heating_damper_act = ReverseWithLimits ! add_ck_vav_bot = Yes ! add_ck_vav_mid = Yes ! add_ck_vav_top = Yes ! core_bottom_mdp = 0.2 ! perimeter_bot_zn_1_mdp = 0.2 ! perimeter_bot_zn_2_mdp = 0.2 ! perimeter_bot_zn_3_mdp = 0.2 ! perimeter_bot_zn_4_mdp = 0.2 ! core_mid_mdp = 0.2 ! perimeter_mid_zn_1_mdp = 0.2 ! perimeter_mid_zn_2_mdp = 0.2 ! perimeter_mid_zn_3_mdp = 0.2 ! perimeter_mid_zn_4_mdp = 0.2 ! core_top_mdp = 0.2 ! perimeter_top_zn_1_mdp = 0.2 ! perimeter_top_zn_2_mdp = 0.2 ! perimeter_top_zn_3_mdp = 0.2 ! perimeter_top_zn_4_mdp = 0.2 ! vav_bot_oaf = autosize ! vav_mid_oaf = autosize ! vav_top_oaf = autosize ! BLDG_ELEVATORS_LIGHTS_FAN_SCH = ELEV_LIGHT_FAN_SCH_ADD_DF ! BLDG_ELEVATORS_LIGHTS_FAN_POWER = 752 ! bsmt_new = National_OfficeLarge_ASHRAE901_STD2016_Zone6A_nonres_MN-Rochester-MN_out.idf ! osc_key_wall = surfPropOthSdCoefBasementAvgWall ! osc_key_floor = surfPropOthSdCoefBasementAvgFloor ! BLDG_EQUIP_SCH = BLDG_EQUIP_SCH_ADV ! addendum_cd = 2016AS ! PumpCurve_flag = pump_ride_on_curve ! pv_generator = no ! pv_surface_area = 0 ! STD189_overhang = no ! swh_et = 0.803988738 ! swh_ua = 11.25413987 ! ext_lgt_sch = Exterior_Lgt_ALWAYS_ON ! VAV_bot_WITH_REHEAT_ERV = Yes ! VAV_mid_WITH_REHEAT_ERV = Yes ! VAV_top_WITH_REHEAT_ERV = Yes ! CAV_bas_ERV_power = 911.0574 ! VAV_bot_WITH_REHEAT_ERV_power = 1506.812 ! VAV_mid_WITH_REHEAT_ERV_power = 1506.812 ! VAV_top_WITH_REHEAT_ERV_power = 1506.812 ! LTG_SCH_SET = LTG_SET_STD2013 ! transformer_size = 500000 ! transformer_eff = 0.991 ! economizer_coredatacenter = DifferentialDryBulb ! economizer_itcloset = NoEconomizer ! HtgSetP_Sch = HTGSETP_SCH_YES_OPTIMUM ! ClgSetP_Sch = CLGSETP_SCH_YES_OPTIMUM ! wwr = 0.4 ! pipe_heat_loss = 7280.88 ! add_as = yes ! preheatcoil_exists = no ! AddendumAF_TowerFan = Yes ! skip_EMSprogram = yes ! BoilerAM = Yes ! OA_BASED_OPTIMUM_START_EMS = yes ! OPTIMUM_START_SF_DEPENDENT_EMS = no ! HtgSetP_Sch_CAV_bas = HTGSETP_SCH_YES_OPTIMUM ! ClgSetP_Sch_CAV_bas = CLGSETP_SCH_YES_OPTIMUM ! Wfile_TMY3 = USA_MN_Rochester.Intl.AP.726440_TMY3.epw ! loadProfile = No ! addendum_DV = yes ! receptacle_ctrl_occ_reduction_frac = 0.949143263 ! receptacle_ctrl_unocc_reduction_frac = 0.736941088 ! HOTW_ST_Reset = No ! CHW_ST_Reset = No ! SHW_Pump_Head = 29891 ! CodeName = ASHRAE90.1_STD2019 ! CZ_City_Old = Burlington ! CZ_Label = 6A ! exterior_lights_watts_c = 26027 ! Addendum_AH = Yes ! LPD_Ctrl = 0.02 ! con_swingdoor_r = 0.475963827 ! CHW_deltaT = 8.33 ! HOTW_PumpCurve_flag = pump_ride_on_curve ! office_standby_mode = Yes ! DryClr_GpmperHp = 4.5 ! CRAC_basement = 3.878739046 ! CRAC_IT_closet = 4.005260634 ! nonres_window_u_factor = 0.34 ! nonres_window_shgc = 0.38 ! nonresLSG = 1.1 ! AnalysisPurpose = ProgressIndicator ! AnalysisCodeName = ASHRAE901 ! AnalysisCodeYear = 2019 ! AnalysisAmendment = NoneAmend ! AnalysisPrototype = OfficeLarge ! AnalysisScope = National ! AnalysisState = National ! AnalysisClimateZone = 6A ! AnalysisCity = USA_MN_Rochester ! var_Ffactor_IP = 0.51 ! var_Cfactor_IP = 0.092 ! Core_ZN_SWH_flow = 3.66667e-05 ! specify overhang_pf for 1891 codes Version,9.0; !- =========== ALL OBJECTS IN CLASS: BUILDING =========== Building, OfficeLarge, !- Name 0.0000, !- North Axis {deg} City, !- Terrain 0.0400, !- Loads Convergence Tolerance Value 0.2000, !- Temperature Convergence Tolerance Value {deltaC} FullInteriorAndExterior, !- Solar Distribution 25, !- Maximum Number of Warmup Days 6; !- Minimum Number of Warmup Days !- =========== ALL OBJECTS IN CLASS: TIMESTEP IN HOUR =========== Timestep,6; ConvergenceLimits, 1, !- Minimum System Timestep {minutes} 20; !- Maximum HVAC Iterations !- =========== ALL OBJECTS IN CLASS: SYSTEM CONVERGENCE LIMITS =========== !- =========== ALL OBJECTS IN CLASS: INSIDE CONVECTION ALGORITHM =========== SurfaceConvectionAlgorithm:Inside,TARP; !- =========== ALL OBJECTS IN CLASS: OUTSIDE CONVECTION ALGORITHM =========== SurfaceConvectionAlgorithm:Outside,TARP; !- =========== ALL OBJECTS IN CLASS: SOLUTION ALGORITHM =========== HeatBalanceAlgorithm,ConductionTransferFunction; !- =========== ALL OBJECTS IN CLASS: SHADOWING CALCULATIONS =========== ShadowCalculation, AverageOverDaysInFrequency, !- Calculation Method 30; !- Calculation Frequency !- =========== ALL OBJECTS IN CLASS: RUN CONTROL =========== SimulationControl, Yes, !- Do Zone Sizing Calculation Yes, !- Do System Sizing Calculation Yes, !- Do Plant Sizing Calculation No, !- Run Simulation for Sizing Periods YES; !- Run Simulation for Weather File Run Periods !- =========== ALL OBJECTS IN CLASS: RUNPERIOD =========== RunPeriod, , !- Name 1, !- Begin Month 1, !- Begin Day of Month , !- Begin Year 12, !- End Month 31, !- End Day of Month , !- End Year Sunday, !- Day of Week for Start Day No, !- Use Weather File Holidays and Special Days No, !- Use Weather File Daylight Saving Period No, !- Apply Weekend Holiday Rule Yes, !- Use Weather File Rain Indicators Yes; !- Use Weather File Snow Indicators !- =========== ALL OBJECTS IN CLASS: SPECIALDAYPERIOD =========== RunPeriodControl:SpecialDays, New Years Day, !- Name January 1, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Veterans Day, !- Name November 11, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Christmas, !- Name December 25, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Independence Day, !- Name July 4, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, MLK Day, !- Name 3rd Monday in January, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Presidents Day, !- Name 3rd Monday in February, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Memorial Day, !- Name Last Monday in May, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Labor Day, !- Name 1st Monday in September, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Columbus Day, !- Name 2nd Monday in October, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Thanksgiving, !- Name 4th Thursday in November,!- Start Date 1, !- Duration {days} Holiday; !- Special Day Type !- =========== ALL OBJECTS IN CLASS: DAYLIGHTSAVINGPERIOD =========== RunPeriodControl:DaylightSavingTime, 2nd Sunday in March, !- Start Date 1st Sunday in November; !- End Date !- =========== ALL OBJECTS IN CLASS: LOCATION =========== ! Site:Location and design-day objects created by: ! ../../_p.bin/ddy2idf /projects/bigsim/weather/EnergyPlus/tmy3.new/all/USA_MN_Rochester.Intl.AP.726440_TMY3.ddy ! Site:Location, Rochester International Arpt_MN_USA Design_Conditions, !- Site:Location Name 43.90, !- Latitude {N+ S-} -92.50, !- Longitude {W- E+} -6.00, !- Time Zone Relative to GMT {GMT+/-} 398.00; !- Elevation {m} SizingPeriod:DesignDay, Rochester International Arpt Ann Htg 99.6% Condns DB, !- Name 1, !- Month 21, !- Day of Month WinterDesignDay,!- Day Type -26.2, !- Maximum Dry-Bulb Temperature {C} 0.0, !- Daily Dry-Bulb Temperature Range {C} DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type , !- Dry-Bulb Temperature Range Modifier Schedule Name Wetbulb, !- Humidity Condition Type -26.2, !- Wetbulb at Maximum Dry-Bulb {C} , !- Humidity Indicating Day Schedule Name , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} , !- Enthalpy at Maximum Dry-Bulb {J/kg} , !- Daily WetBulb Temperature Range {deltaC} 96634., !- Barometric Pressure {Pa} 5.7, !- Wind Speed {m/s} design conditions vs. traditional 6.71 m/s (15 mph) 310, !- Wind Direction {Degrees; N=0, S=180} No, !- Rain {Yes/No} No, !- Snow on ground {Yes/No} No, !- Daylight Savings Time Indicator ASHRAEClearSky, !- Solar Model Indicator , !- Beam Solar Day Schedule Name , !- Diffuse Solar Day Schedule Name , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) 0.00; !- Clearness {0.0 to 1.1} SizingPeriod:DesignDay, Rochester International Arpt Ann Clg .4% Condns DB=>MWB, !- Name 7, !- Month 21, !- Day of Month SummerDesignDay,!- Day Type 31.2, !- Maximum Dry-Bulb Temperature {C} 10.6, !- Daily Dry-Bulb Temperature Range {C} DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type , !- Dry-Bulb Temperature Range Modifier Schedule Name Wetbulb, !- Humidity Condition Type 23.1, !- Wetbulb at Maximum Dry-Bulb {C} , !- Humidity Indicating Day Schedule Name , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} , !- Enthalpy at Maximum Dry-Bulb {J/kg} , !- Daily WetBulb Temperature Range {deltaC} 96634., !- Barometric Pressure {Pa} 6.7, !- Wind Speed {m/s} design conditions vs. traditional 3.35 m/s (7mph) 200, !- Wind Direction {Degrees; N=0, S=180} No, !- Rain {Yes/No} No, !- Snow on ground {Yes/No} No, !- Daylight Savings Time Indicator ASHRAETau, !- Solar Model Indicator , !- Beam Solar Day Schedule Name , !- Diffuse Solar Day Schedule Name 0.404, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) 2.226; !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) !- =========== ALL OBJECTS IN CLASS: WATER MAINS TEMPERATURES =========== Site:WaterMainsTemperature, Correlation, !- Calculation Method , !- Temperature Schedule Name 6.375, !- Annual average outdoor air temperature {C} 33.5; !- Maximum difference in monthly average outdoor air temperatures {C} !- =========== ALL OBJECTS IN CLASS: Site:GroundTemperature:FCfactorMethod =========== Site:GroundTemperature:FCfactorMethod, 7.4, !- January Ground Temperature {C} -0.0, !- February Ground Temperature {C} -7.6, !- March Ground Temperature {C} -12.6, !- April Ground Temperature {C} -7.7, !- May Ground Temperature {C} 0.3, !- June Ground Temperature {C} 7.0, !- July Ground Temperature {C} 14.2, !- August Ground Temperature {C} 19.2, !- September Ground Temperature {C} 20.9, !- October Ground Temperature {C} 20.0, !- November Ground Temperature {C} 15.4; !- December Ground Temperature {C} !- =========== ALL OBJECTS IN CLASS: MATERIAL:REGULAR-R =========== Material:NoMass, Opaque Door panel_con, !- Name MediumRough, !- Roughness 0.475963827, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance !- =========== ALL OBJECTS IN CLASS: CONSTRUCTION =========== Construction, Swinging Door_con, !- Name Opaque Door panel_con; !- Outside Layer !- =========== Opaque Constructions =========== ! !- =========== ALL OBJECTS IN CLASS: MATERIAL:REGULAR =========== Material, Std Wood 6inch, !- Name MediumSmooth, !- Roughness 0.15, !- Thickness {m} 0.12, !- Conductivity {W/m-K} 540.0000, !- Density {kg/m3} 1210, !- Specific Heat {J/kg-K} 0.9000000, !- Thermal Absorptance 0.7000000, !- Solar Absorptance 0.7000000; !- Visible Absorptance Material, AC02 Acoustic Ceiling, !- Name MediumSmooth, !- Roughness 1.2700000E-02, !- Thickness {m} 5.7000000E-02, !- Conductivity {W/m-K} 288.0000, !- Density {kg/m3} 1339.000, !- Specific Heat {J/kg-K} 0.9000000, !- Thermal Absorptance 0.7000000, !- Solar Absorptance 0.2000000; !- Visible Absorptance Material, F07 25mm stucco, !- Name Smooth, !- Roughness 0.0254, !- Thickness {m} 0.72, !- Conductivity {W/m-K} 1856, !- Density {kg/m3} 840, !- Specific Heat {J/kg-K} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material, F08 Metal surface, !- Name Smooth, !- Roughness 0.0008, !- Thickness {m} 45.28, !- Conductivity {W/m-K} 7824, !- Density {kg/m3} 500; !- Specific Heat {J/kg-K} Material, F08 Metal roof surface, !- Name Smooth, !- Roughness 0.0008, !- Thickness {m} 45.28, !- Conductivity {W/m-K} 7824, !- Density {kg/m3} 500, !- Specific Heat {J/kg-K} 0.9, !- Absorptance:Thermal 0.7; !- Absorptance:Solar Material, F12 Asphalt shingles, !- Name VeryRough, !- Roughness 0.0032, !- Thickness {m} 0.04, !- Conductivity {W/m-K} 1120, !- Density {kg/m3} 1260, !- Specific Heat {J/kg-K} 0.9, !- Absorptance:Thermal 0.7; !- Absorptance:Solar Material, F13 Built-up roofing, !- Name Rough, !- Roughness 0.0095, !- Thickness {m} 0.16, !- Conductivity {W/m-K} 1120, !- Density {kg/m3} 1460, !- Specific Heat {J/kg-K} 0.9, !- Absorptance:Thermal 0.7; !- Absorptance:Solar Material, G01 13mm gypsum board, !- Name Smooth, !- Roughness 0.0127, !- Thickness {m} 0.1600, !- Conductivity {W/m-K} 800.0000, !- Density {kg/m3} 1090.0000, !- Specific Heat {J/kg-K} 0.9000, !- Absorptance:Thermal 0.7000, !- Absorptance:Solar 0.5000; !- Absorptance:Visible Material, G01 16mm gypsum board, !- Name MediumSmooth, !- Roughness 0.0159, !- Thickness {m} 0.16, !- Conductivity {W/m-K} 800, !- Density {kg/m3} 1090; !- Specific Heat {J/kg-K} Material, G02 16mm plywood, !- Name Smooth, !- Roughness 0.0159, !- Thickness {m} 0.12, !- Conductivity {W/m-K} 544, !- Density {kg/m3} 1210; !- Specific Heat {J/kg-K} Material, M14 150mm heavyweight concrete roof, !- Name MediumRough, !- Roughness 0.1524, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 100mm Normalweight concrete wall, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.1016, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 200mm Normalweight concrete wall, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.2032, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 100mm Normalweight concrete floor, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.1016, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 150mm Normalweight concrete floor, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.1524, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 200mm Normalweight concrete floor, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.2032, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, M10 200mm concrete block wall, !- Name MediumRough, !- Roughness 0.2032, !- Thickness {m} 0.72, !- Conductivity {W/m-K} 800, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, M10 200mm concrete block basement wall, !- Name MediumRough, !- Roughness 0.2032, !- Thickness {m} 1.326, !- Conductivity {W/m-K} 1842, !- Density {kg/m3} 912; !- Specific Heat {J/kg-K} Material:NoMass, CP02 CARPET PAD, !- Name VeryRough, !- Roughness 0.21648, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.8; !- Visible Absorptance Material:NoMass, Air_Wall_Material, !- Name Rough, !- Roughness 0.2079491, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7; !- Solar Absorptance Material:NoMass, Nonres_Roof_Insulation, !- Name MediumSmooth, !- Roughness 5.30668495131472, !- Thermal Resistance {m2-K/W} 0.9, !- Absorptance:Thermal 0.7, !- Absorptance:Solar 0.7; !- Absorptance:Visible Material:NoMass, Res_Roof_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Semiheated_Roof_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Nonres_Exterior_Wall_Insulation, !- Name MediumSmooth, !- Roughness 1.88434339518544, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Res_Exterior_Wall_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Semiheated_Exterior_Wall_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Nonres_Floor_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Res_Floor_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Semiheated_Floor_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Std Opaque Door Panel, !- Name MediumRough, !- Roughness 0.123456790123457, !- (corresponds to default RSI-0.12327 or R-0.7) Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance !- =========== ALL OBJECTS IN CLASS: CONSTRUCTION =========== Construction, InteriorFurnishings, !- Name Std Wood 6inch; !- Outside Layer Construction, Air_Wall, !- Name Air_Wall_Material; !- Outside Layer Construction, DropCeiling, !- Name AC02 Acoustic Ceiling; !- Outside Layer Construction, OpaqueDoor, !- Name Std Opaque Door Panel; !- Outside Layer Construction, AtticRoofDeck, !- Name F12 Asphalt shingles, !- Outside Layer G02 16mm plywood; !- Layer 2 Construction, int_wall, !- Name G01 13mm gypsum board, !- Outside Layer G01 13mm gypsum board; !- Layer 2 Construction, ext_slab_8in_with_carpet,!- Name 200mm Normalweight concrete floor, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, ext_slab_8in, !- Name 200mm Normalweight concrete floor; !- Outside Layer Construction, ext_slab_6in_with_carpet,!- Name 150mm Normalweight concrete floor, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, ext_slab_6in, !- Name 150mm Normalweight concrete floor; !- Outside Layer Construction, int_slab_floor, !- Name 100mm Normalweight concrete floor, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, int_slab_ceiling, !- Name CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor; !- Layer 2 Construction, basement_wall, !- Name M10 200mm concrete block basement wall; !- Outside Layer Construction, int_wood_floor, !- Name AC02 Acoustic Ceiling, !- Outside Layer G02 16mm plywood, !- Layer 2 CP02 CARPET PAD; !- Layer 3 Construction, ext_soffit_floor, !- Name G02 16mm plywood; !- Outside Layer Construction, nonres_roof, !- Name F13 Built-up roofing, !- Outside Layer Nonres_Roof_Insulation, !- Layer #2 F08 Metal surface; !- Layer #3 Construction, res_roof, !- Name F13 Built-up roofing, !- Outside Layer Res_Roof_Insulation, !- Layer #2 F08 Metal surface; !- Layer #3 Construction, semiheated_roof, !- Name F13 Built-up roofing, !- Outside Layer Semiheated_Roof_Insulation, !- Layer #2 F08 Metal surface; !- Layer #3 Construction, nonres_ext_wall, !- Name 200mm Normalweight concrete wall, !- Outside Layer Nonres_Exterior_Wall_Insulation, !- Layer #2 G01 13mm gypsum board; !- Layer #3 Construction, res_ext_wall, !- Name 200mm Normalweight concrete wall, !- Outside Layer Res_Exterior_Wall_Insulation, !- Layer #2 G01 13mm gypsum board; !- Layer #3 Construction, semiheated_ext_wall, !- Name 200mm Normalweight concrete wall, !- Outside Layer Semiheated_Exterior_Wall_Insulation, !- Layer #2 G01 13mm gypsum board; !- Layer #3 Construction, nonres_floor, !- Name Nonres_Floor_Insulation, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 CP02 CARPET PAD; !- Layer #2 Construction, res_floor, !- Name Res_Floor_Insulation, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 CP02 CARPET PAD; !- Layer #2 Construction, semiheated_floor, !- Name Semiheated_Floor_Insulation, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 CP02 CARPET PAD; !- Layer #2 Construction, nonres_floor_ceiling, !- Name - reverse ordered layers for nonres_floor CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 Nonres_Floor_Insulation; !- Layer #2 Construction, res_floor_ceiling, !- Name - reverse ordered layers for res_floor CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 Res_Floor_Insulation; !- Layer #2 Construction, semiheated_floor_ceiling, !- Name - reverse ordered layers for semiheated_floor CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 Semiheated_Floor_Insulation; !- Layer #2 !- =========== ALL OBJECTS IN CLASS: WINDOWMATERIAL:SIMPLEGLAZINGSYSTEM =========== WindowMaterial:SimpleGlazingSystem, Glazing Layer, !- Name 1.9306084, !- U-Factor {W/m2-K} 0.38, !- Solar Heat Gain Coefficient 0.418; !- Visible Transmittance Construction, Window_U_0.34_SHGC_0.38, !- Name Glazing Layer; !- Outside Layer Construction:CfactorUndergroundWall, Basement_Wall_East_Cfactor, !- Name 0.522376, !- C-Factor 2.439; !- Height Construction:CfactorUndergroundWall, Basement_Wall_South_Cfactor, !- Name 0.522376, !- C-Factor 2.439; !- Height Construction:CfactorUndergroundWall, Basement_Wall_North_Cfactor, !- Name 0.522376, !- C-Factor 2.439; !- Height Construction:CfactorUndergroundWall, DataCenter_basement_ZN_6_Wall_North_Cfactor, !- Name 0.522376, !- C-Factor 2.439; !- Height Construction:CfactorUndergroundWall, DataCenter_basement_ZN_6_Wall_South_Cfactor, !- Name 0.522376, !- C-Factor 2.439; !- Height Construction:CfactorUndergroundWall, DataCenter_basement_ZN_6_Wall_West_Cfactor, !- Name 0.522376, !- C-Factor 2.439; !- Height !- =========== ALL OBJECTS IN CLASS: ZONE =========== Zone, Basement, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Core_bottom, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Core_mid, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 10.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Core_top, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_bot_ZN_3, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_bot_ZN_2, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_bot_ZN_1, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_bot_ZN_4, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_mid_ZN_3, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 10.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_mid_ZN_2, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 10.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_mid_ZN_1, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 10.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_mid_ZN_4, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 10.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_top_ZN_3, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_top_ZN_2, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_top_ZN_1, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, Perimeter_top_ZN_4, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm YES; !- Part of Total Floor Area Zone, GroundFloor_Plenum, !- Name 0.0, !- Direction of Relative North {deg} 0.0, !- X Origin {m} 0.0, !- Y Origin {m} 0, !- Z Origin {m} , !- Type 1, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm No; !- Part of Total Floor Area Zone, MidFloor_Plenum, !- Name 0.0, !- Direction of Relative North {deg} 0.0, !- X Origin {m} 0.0, !- Y Origin {m} 0, !- Z Origin {m} , !- Type 10, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm No; !- Part of Total Floor Area Zone, TopFloor_Plenum, !- Name 0.0, !- Direction of Relative North {deg} 0.0, !- X Origin {m} 0.0, !- Y Origin {m} 0, !- Z Origin {m} , !- Type 1, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm No; !- Part of Total Floor Area Zone, DataCenter_bot_ZN_6, !- Name 0.0, !- Direction of Relative North {deg} 5.4876, !- X Origin {m} 44.165, !- Y Origin {m} 0.0, !- Z Origin {m} , !- Type 1; !- Multiplier Zone, DataCenter_mid_ZN_6, !- Name 0.0, !- Direction of Relative North {deg} 4.5732, !- X Origin {m} 4.5732, !- Y Origin {m} 16.7683, !- Z Origin {m} , !- Type 10; !- Multiplier Zone, DataCenter_top_ZN_6, !- Name 0.0, !- Direction of Relative North {deg} 4.5732, !- X Origin {m} 4.5732, !- Y Origin {m} 33.5366, !- Z Origin {m} , !- Type 1; !- Multiplier Zone, DataCenter_basement_ZN_6,!- Name 0.0, !- Direction of Relative North {deg} 16.0794, !- X Origin {m} 0.0, !- Y Origin {m} -2.439, !- Z Origin {m} , !- Type 1; !- Multiplier !- =========== ALL OBJECTS IN CLASS: SURFACEGEOMETRY =========== GlobalGeometryRules, ULC, !- Starting Vertex Position CCW, !- Vertex Entry Direction Relative; !- Coordinate System !- =========== ALL OBJECTS IN CLASS: SURFACE:HEATTRANSFER =========== !- =========== ALL OBJECTS IN CLASS: BUILDINGSURFACE:DETAILED =========== BuildingSurface:Detailed, Basement_Wall_East, !- Name Wall, !- Surface Type Basement_Wall_East_Cfactor, !- Construction Name Basement, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,-2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,-2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_2_Floor-PPAutoCreateOther, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name Basement, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_2_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_1_Floor-PPAutoCreateOther, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name Basement, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_1_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.079400000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.079400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Core_bottom, !- Zone Name Zone, !- Outside Boundary Condition GroundFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Ceiling-Core_bot_ZN_5-PPAutoCreateOther, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Core_bottom, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6_Ceiling-Core_bot_ZN_5, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.078200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.078200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_South,!- Name Wall, !- Surface Type int_wall, !- Construction Name Core_bottom, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_bottom, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_East-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_North,!- Name Wall, !- Surface Type int_wall, !- Construction Name Core_bottom, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_bottom, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_East-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Core_mid, !- Zone Name Zone, !- Outside Boundary Condition MidFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Floor, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Core_mid, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Floor, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,16.768300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_South,!- Name Wall, !- Surface Type int_wall, !- Construction Name Core_mid, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_mid, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_North,!- Name Wall, !- Surface Type int_wall, !- Construction Name Core_mid, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_mid, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_East-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Core_top, !- Zone Name Zone, !- Outside Boundary Condition TopFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Floor, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Core_top, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Floor, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,33.536600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_South,!- Name Wall, !- Surface Type int_wall, !- Construction Name Core_top, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_top, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_North,!- Name Wall, !- Surface Type int_wall, !- Construction Name Core_top, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_top, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Wall_East-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_3_Wall_North, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_3_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Zone, !- Outside Boundary Condition GroundFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_3_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_3_Floor-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 16.078200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 16.078200000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_3_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_3_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_North,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_2_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_2_Wall_North, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_2_Wall_East, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_2_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name Zone, !- Outside Boundary Condition GroundFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_2_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_2_Floor-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_2_Wall_North, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_2_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_East-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_1_Wall_East-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_1_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_1_Wall_South, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_1_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Zone, !- Outside Boundary Condition GroundFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6-Perimeter_bot_ZN_1-PPAutoCreateOther, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6_Ceiling-Perimeter_bot_ZN_1, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.078200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.078200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_1_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_1_Wall_East-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_South, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_4_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_4_Wall_South, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_4_Wall_West, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_4_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name Zone, !- Outside Boundary Condition GroundFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_4_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_4_Floor-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_4_Wall_South, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_4_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_West-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_3_Wall_West-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_3_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_3_Wall_North, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_3_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Zone, !- Outside Boundary Condition MidFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_3_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_3_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,16.768300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_3_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_3_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_North,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_2_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_2_Wall_North, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_2_Wall_East, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_2_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name Zone, !- Outside Boundary Condition MidFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_2_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_2_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,16.768300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_2_Wall_North, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_2_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_East-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_1_Wall_East-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_1_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_1_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_1_Wall_East-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_1_Wall_South, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_1_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Zone, !- Outside Boundary Condition MidFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_1_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_1_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,16.768300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_South, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_4_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_4_Wall_South, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_4_Wall_West, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_4_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name Zone, !- Outside Boundary Condition MidFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_4_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_4_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,16.768300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_4_Wall_South, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_4_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_West-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_mid_ZN_3_Wall_West-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_mid_ZN_3_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_3_Wall_North, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_3_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Zone, !- Outside Boundary Condition TopFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_3_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_3_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,33.536600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_3_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_3_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Wall_North,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_2_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_2_Wall_North, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_2_Wall_East, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_top_ZN_2, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_2_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_top_ZN_2, !- Zone Name Zone, !- Outside Boundary Condition TopFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_2_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_top_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_2_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,33.536600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_2_Wall_North, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_2_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_East-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Int-Per3S-NE-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Int-Per3S-NE, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_1_Wall_South, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_1_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Zone, !- Outside Boundary Condition TopFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_1_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_1_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,33.536600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Int-Per3S-NE, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Int-Per3S-NE-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_South, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 5.487600000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 5.487600000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_4_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_4_Wall_South, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_4_Wall_West, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_top_ZN_4, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_4_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name Perimeter_top_ZN_4, !- Zone Name Zone, !- Outside Boundary Condition TopFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_4_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_top_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_4_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,33.536600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_4_Wall_South, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_4_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_West-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 4.573200000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_top_ZN_3_Wall_West-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_top_ZN_3_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, GroundFloor_Plenum_Wall_North, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name GroundFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,3.963200000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,3.963200000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, GroundFloor_Plenum_West, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name GroundFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,3.963200000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,3.963200000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, GroundFloor_Plenum_Wall_South, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name GroundFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,3.963200000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,3.963200000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, GroundFloor_Plenum_Wall_East, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name GroundFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WINDEXPOSED, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,3.963200000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,3.963200000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, MidFloor_Plenum_Wall_North, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name MidFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,20.731500000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,20.731500000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, MidFloor_Plenum_Wall_West, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name MidFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,20.731500000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,20.731500000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, MidFloor_Plenum_Wall_South, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name MidFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,20.731500000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,20.731500000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, MidFloor_Plenum_Wall_East, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name MidFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,20.731500000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,19.512300000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,19.512300000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,20.731500000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, TopFloor_Plenum_Wall_North, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name TopFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,37.499800000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,37.499800000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, TopFloor_Plenum_Wall_East, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name TopFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,0.000000000000,37.499800000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,37.499800000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Building_Roof, !- Name Roof, !- Surface Type nonres_roof, !- Construction Name TopFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,37.499800000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,37.499800000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,37.499800000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,37.499800000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, TopFloor_Plenum_Wall_West, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name TopFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,37.499800000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,37.499800000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, TopFloor_Plenum_Wall_South, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name TopFloor_Plenum, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,37.499800000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,36.280600000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,37.499800000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, GroundFloor_Plenum_Ceiling, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name GroundFloor_Plenum, !- Zone Name Surface, !- Outside Boundary Condition GroundFloor_Plenum_Ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,3.963200000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,3.963200000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,3.963200000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,3.963200000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, MidFloor_Plenum_Ceiling, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name MidFloor_Plenum, !- Zone Name Surface, !- Outside Boundary Condition MidFloor_Plenum_Ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure autocalculate, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,20.731500000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,20.731500000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,20.731500000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,20.731500000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Floor, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name DataCenter_bot_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Floor-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,-39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} -0.914400000000,-39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} -0.914400000000,0.000000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_North, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_bot_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} -0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} -0.914400000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_South, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_bot_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -0.914400000000,-39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} -0.914400000000,-39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,-39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,-39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_East-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_bot_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,-39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,-39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name DataCenter_bot_ZN_6, !- Zone Name Zone, !- Outside Boundary Condition GroundFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -0.914400000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} -0.914400000000,-39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,-39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_bot_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -0.914400000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} -0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} -0.914400000000,-39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} -0.914400000000,-39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Wall_North, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Wall_South,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,4.573200000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Floor, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name DataCenter_mid_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Floor, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.914400000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,39.591800000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_mid_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_South, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_mid_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.914400000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_mid_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.914400000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.914400000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.914400000000,39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_North, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_mid_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.914400000000,39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.914400000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name DataCenter_mid_ZN_6, !- Zone Name Zone, !- Outside Boundary Condition MidFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 0.914400000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 0.914400000000,39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_mid_ZN_5_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Core_mid_ZN_5_Wall_South,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,4.573200000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_mid_ZN_6_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_mid_ZN_6_Wall_North, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,19.512300000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,44.165000000000,16.768300000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,19.512300000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_North-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_North, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 4.573200000000,44.165000000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 4.573200000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,44.165000000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,44.165000000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_top_ZN_5_Wall_South-PPAutoCreateOther, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_top_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Wall_South,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,36.280600000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 2 {m} 5.487600000000,4.573200000000,33.536600000000, !- X,Y,Z ==> Vertex 3 {m} 5.487600000000,4.573200000000,36.280600000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Floor, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name DataCenter_top_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Floor, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.914400000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,39.591800000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_top_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition Core_top_ZN_5_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.914400000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.914400000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.914400000000,39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_top_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_West-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_South, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_top_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_South-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.914400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.914400000000,0.000000000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_ceiling, !- Name Ceiling, !- Surface Type DropCeiling, !- Construction Name DataCenter_top_ZN_6, !- Zone Name Zone, !- Outside Boundary Condition TopFloor_Plenum, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 2 {m} 0.914400000000,0.000000000000,2.744000000000, !- X,Y,Z ==> Vertex 3 {m} 0.914400000000,39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_top_ZN_6_Wall_North, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_top_ZN_6, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_top_ZN_6_Wall_North-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.914400000000,39.591800000000,2.744000000000, !- X,Y,Z ==> Vertex 1 {m} 0.914400000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,39.591800000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,39.591800000000,2.744000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Floor-PPAutoCreateOther, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name Basement, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Floor, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.079400000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.079400000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 68.534000000000,44.165000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_bot_ZN_5_Floor, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Core_bottom, !- Zone Name Surface, !- Outside Boundary Condition Core_bot_ZN_5_Floor-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 16.078200000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 16.078200000000,44.165000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_3_Floor-PPAutoCreateOther, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name Basement, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_3_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.079400000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.079400000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 68.534000000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Basement_Wall_South, !- Name Wall, !- Surface Type Basement_Wall_South_Cfactor, !- Construction Name Basement, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.079400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.079400000000,0.000000000000,-2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,0.000000000000,-2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,0.000000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Basement_Floor, !- Name Floor, !- Surface Type ext_slab_8in_with_carpet,!- Construction Name Basement, !- Zone Name Adiabatic, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,-2.439000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,-2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 16.079400000000,0.000000000000,-2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 16.079400000000,48.738100000000,-2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Basement_Wall_North, !- Name Wall, !- Surface Type Basement_Wall_North_Cfactor, !- Construction Name Basement, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 73.107200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,48.738100000000,-2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 16.079400000000,48.738100000000,-2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 16.079400000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Basement_Wall_West, !- Name Wall, !- Surface Type int_wall, !- Construction Name Basement, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6_Wall_East, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.079400000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.079400000000,48.738100000000,-2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 16.079400000000,0.000000000000,-2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 16.079400000000,0.000000000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Floor, !- Name Floor, !- Surface Type ext_slab_8in_with_carpet,!- Construction Name DataCenter_basement_ZN_6,!- Zone Name Adiabatic, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} -16.079400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} -16.079400000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Wall_North, !- Name Wall, !- Surface Type DataCenter_basement_ZN_6_Wall_North_Cfactor, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -0.001200000000,48.738100000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} -16.079400000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} -16.079400000000,48.738100000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Wall_South, !- Name Wall, !- Surface Type DataCenter_basement_ZN_6_Wall_South_Cfactor, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -16.079400000000,0.000000000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -16.079400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Wall_West, !- Name Wall, !- Surface Type DataCenter_basement_ZN_6_Wall_West_Cfactor, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -16.079400000000,48.738100000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -16.079400000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} -16.079400000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} -16.079400000000,0.000000000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_bot_ZN_6_Floor-PPAutoCreateOther, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name Surface, !- Outside Boundary Condition DataCenter_bot_ZN_6_Floor, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -11.506200000000,44.165000000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -11.506200000000,4.573200000000,2.439000000000, !- X,Y,Z ==> Vertex 2 {m} -10.591800000000,4.573200000000,2.439000000000, !- X,Y,Z ==> Vertex 3 {m} -10.591800000000,44.165000000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Ceiling-Core_bot_ZN_5, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6_Ceiling-Core_bot_ZN_5-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -10.591800000000,44.165000000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -10.591800000000,4.573200000000,2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,4.573200000000,2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,44.165000000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_4_Floor-PPAutoCreateOther, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_4_Floor,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -16.079400000000,48.738100000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -16.079400000000,0.000000000000,2.439000000000, !- X,Y,Z ==> Vertex 2 {m} -11.506200000000,4.573200000000,2.439000000000, !- X,Y,Z ==> Vertex 3 {m} -11.506200000000,44.165000000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Ceiling-Perimeter_bot_ZN_1, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6-Perimeter_bot_ZN_1-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -11.506200000000,4.573200000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -16.079400000000,0.000000000000,2.439000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,0.000000000000,2.439000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,4.573200000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Ceiling-Perimeter_bot_ZN_3, !- Name Ceiling, !- Surface Type int_slab_ceiling, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6_Ceiling-Perimeter_bot_ZN_3-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices -16.079400000000,48.738100000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} -11.506200000000,44.165000000000,2.439000000000, !- X,Y,Z ==> Vertex 2 {m} -0.001200000000,44.165000000000,2.439000000000, !- X,Y,Z ==> Vertex 3 {m} -0.001200000000,48.738100000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_bot_ZN_1_Floor,!- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_bot_ZN_1_Floor-PPAutoCreateOther, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 68.534000000000,4.573200000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 16.078200000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 16.078200000000,4.573200000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Ceiling-Perimeter_bot_ZN_3-PPAutoCreateOther, !- Name Floor, !- Surface Type int_slab_floor, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition DataCenter_basement_ZN_6_Ceiling-Perimeter_bot_ZN_3, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 16.078200000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 1 {m} 16.078200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 4.573200000000,44.165000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,0.000000000000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, DataCenter_basement_ZN_6_Wall_East, !- Name Wall, !- Surface Type int_wall, !- Construction Name DataCenter_basement_ZN_6,!- Zone Name Surface, !- Outside Boundary Condition Basement_Wall_West, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure 0.0, !- View Factor to Ground 4, !- Number of Vertices 0.000000000000,0.000000000000,2.439000000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,2.439000000000; !- X,Y,Z ==> Vertex 4 {m} !- =========== ALL OBJECTS IN CLASS: SURFACE:HEATTRANSFER:SUB =========== FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Window1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107000000000,48.738100000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 73.10700,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 59.46085,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 59.460850000000,48.738100000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Window2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 58.241650000000,48.738100000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 58.24165,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 44.59550,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 44.595500000000,48.738100000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Window3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 43.376300000000,48.738100000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 43.37630,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 29.73015,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 29.730150000000,48.738100000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Window4, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 28.510950000000,48.738100000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 28.51095,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 14.86480,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 14.864800000000,48.738100000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Window5, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 13.645600000000,48.738100000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 13.64560,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 0.00000,48.73810,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,48.738100000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_2_Wall_East_Window1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107200000000,0.000000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 73.10720,0.00000,0.8312233024, !- X,Y,Z ==> Vertex 2 {m} 73.10720,15.433294,0.8312233024, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,15.433294000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_2_Wall_East_Window2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107200000000,16.652494000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 73.10720,16.652494,0.8312233024, !- X,Y,Z ==> Vertex 2 {m} 73.10720,32.085788,0.8312233024, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,32.085788000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_2_Wall_East_Window3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107200000000,33.304988000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 73.10720,33.304988,0.8312233024, !- X,Y,Z ==> Vertex 2 {m} 73.10720,48.73800,0.8312233024, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,48.738000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Window1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000000000,0.000000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 0.00000,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 13.64615,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 13.646150000000,0.000000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Window2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 14.865350000000,0.000000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 14.86535,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 28.51150,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 28.511500000000,0.000000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Window3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 29.730700000000,0.000000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 29.73070,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 43.37685,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 43.376850000000,0.000000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Window4, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 44.596050000000,0.000000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 44.59605,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 58.24220,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 58.242200000000,0.000000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Window5, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 59.461400000000,0.000000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 59.46140,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 2 {m} 73.10700,0.00000,0.8014041856, !- X,Y,Z ==> Vertex 3 {m} 73.107000000000,0.000000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_4_Wall_West_Window1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000000000,48.738000000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 0.00000,48.73800,0.8312233024, !- X,Y,Z ==> Vertex 2 {m} 0.00000,33.304706,0.8312233024, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,33.304706000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_4_Wall_West_Window2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000000000,32.085506000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 0.00000,32.085506,0.8312233024, !- X,Y,Z ==> Vertex 2 {m} 0.00000,16.652212,0.8312233024, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,16.652212000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_4_Wall_West_Window3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_bot_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000000000,15.433012000000,2.500000000000, !- X,Y,Z ==> Vertex 1 {m} 0.00000,15.433012,0.8312233024, !- X,Y,Z ==> Vertex 2 {m} 0.00000,0.00000,0.8312233024, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,0.000000000000,2.500000000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_mid_ZN_3_Wall_North_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_mid_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107000,48.738100,19.268300, !- X,Y,Z ==> Vertex 1 {m} 73.107000,48.738100,17.68302, !- X,Y,Z ==> Vertex 2 {m} 0.0000,48.738100,17.68302, !- X,Y,Z ==> Vertex 3 {m} 0.000000,48.738100,19.268300; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_mid_ZN_2_Wall_East_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_mid_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107200,0.000000,19.268300, !- X,Y,Z ==> Vertex 1 {m} 73.107200,0.0000,17.68302, !- X,Y,Z ==> Vertex 2 {m} 73.107200,48.738000,17.68302, !- X,Y,Z ==> Vertex 3 {m} 73.107200,48.738000,19.268300; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_mid_ZN_1_Wall_South_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_mid_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000,0.000000,19.268300, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,17.68302, !- X,Y,Z ==> Vertex 2 {m} 73.107000,0.0000,17.68302, !- X,Y,Z ==> Vertex 3 {m} 73.107000,0.000000,19.268300; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_mid_ZN_4_Wall_West_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_mid_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000,48.738000,19.268300, !- X,Y,Z ==> Vertex 1 {m} 0.0000,48.738000,17.68302, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,17.68302, !- X,Y,Z ==> Vertex 3 {m} 0.000000,0.000000,19.268300; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_top_ZN_3_Wall_North_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_top_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107000,48.738100,36.036600, !- X,Y,Z ==> Vertex 1 {m} 73.107000,48.738100,34.45132, !- X,Y,Z ==> Vertex 2 {m} 0.000000,48.738100,34.45132, !- X,Y,Z ==> Vertex 3 {m} 0.000000,48.738100,36.036600; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_top_ZN_2_Wall_East_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_top_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 73.107200,0.000000,36.036600, !- X,Y,Z ==> Vertex 1 {m} 73.107200,0.000000,34.45132, !- X,Y,Z ==> Vertex 2 {m} 73.107200,48.738000,34.45132, !- X,Y,Z ==> Vertex 3 {m} 73.107200,48.738000,36.036600; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_top_ZN_1_Wall_South_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_top_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000,0.000000,36.036600, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,34.45132, !- X,Y,Z ==> Vertex 2 {m} 73.107000,0.0000,34.45132, !- X,Y,Z ==> Vertex 3 {m} 73.107000,0.000000,36.036600; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_top_ZN_4_Wall_West_Window, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_top_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000000,48.738000,36.036600, !- X,Y,Z ==> Vertex 1 {m} 0.0000,48.738000,34.45132, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,34.45132, !- X,Y,Z ==> Vertex 3 {m} 0.000000,0.000000,36.036600; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_4_Wall_West_Door1, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 0.000000000000,33.185179805763,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,33.185179805763,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,32.270779805763,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,32.270779805763,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_4_Wall_West_Door2, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_4_Wall_West, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 0.000000000000,16.552817982567,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 0.000000000000,16.552817982567,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 0.000000000000,15.638417982567,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 0.000000000000,15.638417982567,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Door1, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 13.810736114328,0.000000000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 13.810736114328,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 14.725136114328,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 14.725136114328,0.000000000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Door2, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 28.643695630079,0.000000000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 28.643695630079,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 29.558095630079,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 29.558095630079,0.000000000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Door3, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 43.526278450605,0.000000000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 43.526278450605,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 44.440678450605,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 44.440678450605,0.000000000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_1_Wall_South_Door4, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_1_Wall_South, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 58.430380500539,0.000000000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 58.430380500539,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 59.344780500539,0.000000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 59.344780500539,0.000000000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_2_Wall_East_Door1, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 73.107200000000,15.598040704848,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,15.598040704848,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,16.512440704848,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,16.512440704848,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_2_Wall_East_Door2, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_2_Wall_East, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 73.107200000000,32.208787109866,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 73.107200000000,32.208787109866,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 73.107200000000,33.123187109866,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 73.107200000000,33.123187109866,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Door1, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 59.294409384709,48.738100000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 59.294409384709,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 58.380009384709,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 58.380009384709,48.738100000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Door2, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 44.438376131067,48.738100000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 44.438376131067,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 43.523976131067,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 43.523976131067,48.738100000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Door3, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 29.612533284962,48.738100000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 29.612533284962,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 28.698133284962,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 28.698133284962,48.738100000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_bot_ZN_3_Wall_North_Door4, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_bot_ZN_3_Wall_North, !- Building Surface Name , !- Outside Boundary Condition Object , !- View Factor to Ground , !- Frame and Divider Name , !- Multiplier 4, !- Number of Vertices 14.737252885612,48.738100000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 14.737252885612,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 13.822852885612,48.738100000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 13.822852885612,48.738100000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} !- =========== ALL OBJECTS IN CLASS: SURFACE:HEATTRANSFER:INTERNALMASS =========== InternalMass, Basement_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Basement, !- Zone Name 7126.2120; !- Surface Area {m2} InternalMass, Core_bottom_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Core_bottom, !- Zone Name 5064.6526; !- Surface Area {m2} InternalMass, Core_mid_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Core_mid, !- Zone Name 5064.6526; !- Surface Area {m2} InternalMass, Core_top_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Core_top, !- Zone Name 5064.6526; !- Surface Area {m2} InternalMass, Perimeter_bot_ZN_3_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_bot_ZN_3, !- Zone Name 626.8258; !- Surface Area {m2} InternalMass, Perimeter_bot_ZN_2_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_bot_ZN_2, !- Zone Name 403.9504; !- Surface Area {m2} InternalMass, Perimeter_bot_ZN_1_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_bot_ZN_1, !- Zone Name 626.8354; !- Surface Area {m2} InternalMass, Perimeter_bot_ZN_4_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_bot_ZN_4, !- Zone Name 403.9478; !- Surface Area {m2} InternalMass, Perimeter_mid_ZN_3_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_mid_ZN_3, !- Zone Name 626.8258; !- Surface Area {m2} InternalMass, Perimeter_mid_ZN_2_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_mid_ZN_2, !- Zone Name 403.9504; !- Surface Area {m2} InternalMass, Perimeter_mid_ZN_1_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_mid_ZN_1, !- Zone Name 626.8354; !- Surface Area {m2} InternalMass, Perimeter_mid_ZN_4_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_mid_ZN_4, !- Zone Name 403.9478; !- Surface Area {m2} InternalMass, Perimeter_top_ZN_3_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_top_ZN_3, !- Zone Name 626.8258; !- Surface Area {m2} InternalMass, Perimeter_top_ZN_2_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_top_ZN_2, !- Zone Name 403.9504; !- Surface Area {m2} InternalMass, Perimeter_top_ZN_1_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_top_ZN_1, !- Zone Name 626.8354; !- Surface Area {m2} InternalMass, Perimeter_top_ZN_4_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_top_ZN_4, !- Zone Name 403.9478; !- Surface Area {m2} !- =========== ALL OBJECTS IN CLASS: SCHEDULETYPE =========== ScheduleTypeLimits, Any Number; !- Name ScheduleTypeLimits, Fraction, !- Name 0.0, !- Lower Limit Value 1.0, !- Upper Limit Value Continuous; !- Numeric Type ScheduleTypeLimits, Temperature, !- Name -60, !- Lower Limit Value 200, !- Upper Limit Value Continuous; !- Numeric Type ScheduleTypeLimits, On/Off, !- Name 0, !- Lower Limit Value 1, !- Upper Limit Value Discrete; !- Numeric Type ScheduleTypeLimits, Control Type, !- Name 0, !- Lower Limit Value 4, !- Upper Limit Value Discrete; !- Numeric Type ScheduleTypeLimits, Humidity, !- Name 10, !- Lower Limit Value 90, !- Upper Limit Value Continuous; !- Numeric Type ScheduleTypeLimits, Number; !- Name !- =========== ALL OBJECTS IN CLASS: SCHEDULE:COMPACT =========== Schedule:Compact, DataCenter_ExtraElecHeatC_Sch, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0; !- Field 3 Schedule:Compact, DataCenter_ExtraWaterHeatC_Sch, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 Schedule:Compact, Exterior_lighting_schedule_a, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0, !- Field 3 Until: 24:00,1; !- Field 5 Schedule:Compact, Exterior_lighting_schedule_b, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0.7, !- Field 3 Until: 24:00,1; !- Field 5 Schedule:Compact, Exterior_lighting_schedule_a_IECC2015, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:Weekdays SummerDesignDay, !- Field 2 Until: 07:00,0, !- Field 3 Until: 22:00,1, !- Field 5 Until: 24:00,0, !- Field 7 For:Saturdays, !- Field 9 Until: 07:00,0, !- Field 10 Until: 18:00,1, !- Field 12 Until: 24:00,0, !- Field 14 For:AllOtherDays, !- Field 16 Until: 24:00,0; !- Field 17 Schedule:Compact, Exterior_lighting_schedule_b_2016, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0.5, !- Field 3 Until: 24:00,1; !- Field 5 Schedule:Compact, Exterior_lighting_schedule_c_2016, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0.5, !- Field 3 Until: 19:00,1, !- Field 5 Until: 24:00,0.5; !- Field 7 Schedule:Compact, Hours_of_operation, !- Name on/off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 06:00,0.0, !- Field 3 Until: 22:00,1.0, !- Field 5 Until: 24:00,0.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 06:00,0.0, !- Field 10 Until: 18:00,1.0, !- Field 12 Until: 24:00,0.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,0.0; !- Field 17 Schedule:Compact, ALWAYS_ON, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, Exterior_Lgt_ALWAYS_ON, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 Schedule:Compact, Exterior_Lgt_189_1, !- Name Fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:Weekdays, !- Field 2 Until: 9:00,0.5, !- Field 3 Until: 24:00,1.0, !- Field 5 For:Saturday, !- Field 7 Until: 9:00,0.5, !- Field 8 Until: 19:00,1.0, !- Field 10 Until: 24:00,0.5, !- Field 12 FOR: Sunday Holidays AllOtherDays, !- Field 14 Until: 9:00,0.5, !- Field 15 Until: 18:00,1.0, !- Field 17 Until: 24:00,0.5; !- Field 19 Schedule:Compact, ALWAYS_OFF, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, HVACOperationSchd, !- Name on/off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 06:00,0.0, !- Field 3 Until: 22:00,1.0, !- Field 5 Until: 24:00,0.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 06:00,0.0, !- Field 10 Until: 18:00,1.0, !- Field 12 Until: 24:00,0.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,0.0; !- Field 17 Schedule:Compact, BLDG_LIGHT_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 5:00,0.05, !- Field 3 Until: 6:00,0.1, !- Field 5 Until: 7:00,0.090560114, !- Field 7 Until: 8:00,0.271680342, !- Field 9 Until: 17:00,0.815041026,!- Field 11 Until: 18:00,0.45280057, !- Field 13 Until: 20:00,0.271680342,!- Field 15 Until: 22:00,0.181120228,!- Field 17 Until: 23:00,0.090560114,!- Field 19 Until: 24:00,0.045280057,!- Field 21 For: SummerDesignDay, !- Field 23 Until: 24:00,1, !- Field 24 For: Saturday, !- Field 26 Until: 6:00,0.05, !- Field 27 Until: 8:00,0.090560114, !- Field 29 Until: 12:00,0.271680342,!- Field 31 Until: 17:00,0.135840171,!- Field 33 Until: 19:00,0.045280057,!- Field 35 Until: 24:00,0.05, !- Field 37 For: WinterDesignDay, !- Field 39 Until: 24:00,0, !- Field 40 For: Sunday Holidays AllOtherDays, !- Field 42 Until: 6:00,0.05, !- Field 43 Until: 18:00,0.045280057,!- Field 45 Until: 24:00,0.05; !- Field 47 Schedule:Compact, EXTERIOR_LIGHT_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 07:00,1.0, !- Field 3 Until: 19:00,0.0, !- Field 5 Until: 24:00,1.0; !- Field 7 Schedule:Compact, BLDG_EQUIP_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 06:00,0.2947764352, !- Field 3 Until: 08:00,0.3796573052, !- Field 5 Until: 12:00,0.8542289367, !- Field 7 Until: 13:00,0.7593146104, !- Field 9 Until: 17:00,0.8542289367, !- Field 11 Until: 18:00,0.4745716315, !- Field 13 Until: 24:00,0.3796573052, !- Field 15 For: SummerDesignDay, !- Field 17 Until: 24:00,1.0, !- Field 18 For: Saturday, !- Field 20 Until: 06:00,0.2210823264, !- Field 21 Until: 08:00,0.3796573052, !- Field 23 Until: 12:00,0.4745716315, !- Field 25 Until: 17:00,0.33220014205, !- Field 27 Until: 19:00,0.2847429789, !- Field 29 Until: 24:00,0.2210823264, !- Field 31 For: WinterDesignDay, !- Field 33 Until: 24:00,0.0, !- Field 34 For: Sunday Holidays AllOtherDays, !- Field 36 Until: 06:00,0.2210823264, !- Field 37 Until: 18:00,0.2847429789, !- Field 39 Until: 24:00,0.2210823264; !- Field 41 Schedule:Compact, DataCenter_EQUIP_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 1/31, !- Field 1 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 2 Until: 24:00, !- Field 3 0.25, !- Field 4 Through: 2/28, !- Field 5 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 6 Until: 24:00, !- Field 7 0.5, !- Field 8 Through: 3/31, !- Field 9 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 10 Until: 24:00, !- Field 11 0.75, !- Field 12 Through: 4/30, !- Field 13 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 14 Until: 24:00, !- Field 15 1, !- Field 16 Through: 5/31, !- Field 17 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 18 Until: 24:00, !- Field 19 0.25, !- Field 20 Through: 6/30, !- Field 21 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 22 Until: 24:00, !- Field 23 0.5, !- Field 24 Through: 7/31, !- Field 25 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 26 Until: 24:00, !- Field 27 0.75, !- Field 28 Through: 8/31, !- Field 29 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 30 Until: 24:00, !- Field 31 1, !- Field 32 Through: 9/30, !- Field 33 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 34 Until: 24:00, !- Field 35 0.25, !- Field 36 Through: 10/31, !- Field 37 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 38 Until: 24:00, !- Field 39 0.5, !- Field 40 Through: 11/30, !- Field 41 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 42 Until: 24:00, !- Field 43 0.75, !- Field 44 Through: 12/31, !- Field 45 For: SummerDesignDay, !- Field 49 Until: 24:00, !- Field 50 1.0, !- Field 51 For: WinterDesignDay, !- Field 52 Until: 24:00, !- Field 53 0.25, !- Field 54 For: AllOtherDays, !- Field 46 Until: 24:00, !- Field 47 1; !- Field 48 Schedule:Compact, BLDG_OCC_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 06:00,0.0, !- Field 3 Until: 07:00,0.1, !- Field 5 Until: 08:00,0.2, !- Field 7 Until: 12:00,0.95, !- Field 9 Until: 13:00,0.5, !- Field 11 Until: 17:00,0.95, !- Field 13 Until: 18:00,0.3, !- Field 15 Until: 22:00,0.1, !- Field 17 Until: 24:00,0.05, !- Field 19 For: SummerDesignDay, !- Field 21 Until: 06:00,0.000000001,!- Field 22 Until: 22:00,1.0, !- Field 24 Until: 24:00,0.05, !- Field 26 For: Saturday, !- Field 28 Until: 06:00,0.0, !- Field 29 Until: 08:00,0.1, !- Field 31 Until: 12:00,0.3, !- Field 33 Until: 17:00,0.1, !- Field 35 Until: 19:00,0.05, !- Field 37 Until: 24:00,0.0, !- Field 39 For: WinterDesignDay, !- Field 41 Until: 24:00,0.0, !- Field 42 For: Sunday Holidays AllOtherDays, !- Field 44 Until: 06:00,0.0, !- Field 45 Until: 18:00,0.05, !- Field 47 Until: 24:00,0.0; !- Field 49 Schedule:Compact, BLDG_OCC_SCH_w_SB, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0.1, Until: 08:00, 0.2, Until: 09:00, 0.95, Until: 10:00, 0.95, Until: 11:00, 0, Until: 12:00, 0.95, Until: 13:00, 0, Until: 14:00, 0.95, Until: 15:00, 0, Until: 16:00, 0.95, Until: 17:00, 0.95, Until: 18:00, 0.3, Until: 19:00, 0.1, Until: 20:00, 0.1, Until: 21:00, 0.1, Until: 22:00, 0.1, Until: 23:00, 0.05, Until: 24:00, 0.05, For: Saturday, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0.1, Until: 08:00, 0.1, Until: 09:00, 0.3, Until: 10:00, 0.3, Until: 11:00, 0, Until: 12:00, 0.3, Until: 13:00, 0, Until: 14:00, 0.1, Until: 15:00, 0, Until: 16:00, 0.1, Until: 17:00, 0.1, Until: 18:00, 0.05, Until: 19:00, 0.05, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: SummerDesignDay, Until: 06:00,0.000000001, Until: 22:00,1.0, Until: 24:00,0.05, For: WinterDesignDay, Until: 24:00,0.0, For:Sunday Holidays AllOtherDays, Until: 06:00,0.0, Until: 18:00,0.05, Until: 24:00,0.0; Schedule:Compact, BLDG_OCC_SCH_wo_SB, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0.1, Until: 08:00, 0.2, Until: 09:00, 0.95, Until: 10:00, 0.95, Until: 11:00, 0.993313428402066, Until: 12:00, 0.95, Until: 13:00, 0.522796541264245, Until: 14:00, 0.95, Until: 15:00, 0.993313428402066, Until: 16:00, 0.95, Until: 17:00, 0.95, Until: 18:00, 0.3, Until: 19:00, 0.1, Until: 20:00, 0.1, Until: 21:00, 0.1, Until: 22:00, 0.1, Until: 23:00, 0.05, Until: 24:00, 0.05, For: Saturday, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0.1, Until: 08:00, 0.1, Until: 09:00, 0.3, Until: 10:00, 0.3, Until: 11:00, 0.313677924758547, Until: 12:00, 0.3, Until: 13:00, 0.104559308252849, Until: 14:00, 0.1, Until: 15:00, 0.104559308252849, Until: 16:00, 0.1, Until: 17:00, 0.1, Until: 18:00, 0.05, Until: 19:00, 0.05, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: SummerDesignDay, Until: 06:00,0.000000001, Until: 22:00,1.0, Until: 24:00,0.05, For: WinterDesignDay, Until: 24:00,0.0, For:Sunday Holidays AllOtherDays, Until: 06:00,0.0, Until: 18:00,0.05, Until: 24:00,0.0; Schedule:Compact, BLDG_ELEVATORS, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 24:00,0.5, !- Field 3 For: WinterDesignDay, !- Field 5 Until: 24:00,0.05, !- Field 6 For: AllOtherDays, !- Field 8 Until: 04:00,0.05, !- Field 9 Until: 05:00,0.10, !- Field 11 Until: 06:00,0.20, !- Field 13 Until: 07:00,0.40, !- Field 15 Until: 09:00,0.50, !- Field 17 Until: 10:00,0.35, !- Field 19 Until: 16:00,0.15, !- Field 21 Until: 17:00,0.35, !- Field 23 Until: 19:00,0.50, !- Field 25 Until: 21:00,0.40, !- Field 27 Until: 22:00,0.30, !- Field 29 Until: 23:00,0.20, !- Field 31 Until: 24:00,0.10; !- Field 33 Schedule:Compact, ELEV_LIGHT_FAN_SCH_24_7, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 Schedule:Compact, ELEV_LIGHT_FAN_SCH_ADD_DF, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 24:00,0.5, !- Field 3 For: WinterDesignDay, !- Field 5 Until: 24:00,0.05, !- Field 6 For: AllOtherDays, !- Field 8 Until: 04:00,0.05, !- Field 9 Until: 05:00,0.10, !- Field 11 Until: 06:00,0.20, !- Field 13 Until: 07:00,0.40, !- Field 15 Until: 09:00,0.50, !- Field 17 Until: 10:00,0.35, !- Field 19 Until: 16:00,0.15, !- Field 21 Until: 17:00,0.35, !- Field 23 Until: 19:00,0.50, !- Field 25 Until: 21:00,0.40, !- Field 27 Until: 22:00,0.30, !- Field 29 Until: 23:00,0.20, !- Field 31 Until: 24:00,0.10; !- Field 33 Schedule:Compact, BLDG_SWH_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 05:00,0.00, !- Field 3 Until: 06:00,0.00, !- Field 5 Until: 07:00,0.07, !- Field 7 Until: 08:00,0.19, !- Field 9 Until: 09:00,0.35, !- Field 11 Until: 10:00,0.38, !- Field 13 Until: 11:00,0.39, !- Field 15 Until: 12:00,0.47, !- Field 17 Until: 13:00,0.57, !- Field 19 Until: 14:00,0.54, !- Field 21 Until: 15:00,0.34, !- Field 23 Until: 16:00,0.33, !- Field 25 Until: 17:00,0.44, !- Field 27 Until: 18:00,0.26, !- Field 29 Until: 19:00,0.21, !- Field 31 Until: 20:00,0.15, !- Field 33 Until: 21:00,0.17, !- Field 35 Until: 22:00,0.08, !- Field 37 Until: 24:00,0.05, !- Field 39 For: Saturday WinterDesignDay, !- Field 41 Until: 05:00,0.00, !- Field 42 Until: 06:00,0.00, !- Field 44 Until: 07:00,0.07, !- Field 46 Until: 08:00,0.11, !- Field 48 Until: 09:00,0.15, !- Field 50 Until: 10:00,0.21, !- Field 52 Until: 11:00,0.19, !- Field 54 Until: 12:00,0.23, !- Field 56 Until: 13:00,0.20, !- Field 58 Until: 14:00,0.19, !- Field 60 Until: 15:00,0.15, !- Field 62 Until: 16:00,0.13, !- Field 64 Until: 17:00,0.14, !- Field 66 Until: 21:00,0.07, !- Field 68 Until: 22:00,0.09, !- Field 70 Until: 24:00,0.05, !- Field 72 For: Sunday Holidays AllOtherDays, !- Field 74 Until: 06:00,0.00, !- Field 75 Until: 07:00,0.07, !- Field 77 Until: 11:00,0.04, !- Field 79 Until: 13:00,0.06, !- Field 81 Until: 14:00,0.09, !- Field 83 Until: 15:00,0.06, !- Field 85 Until: 21:00,0.04, !- Field 87 Until: 22:00,0.07, !- Field 89 Until: 24:00,0.04; !- Field 91 Schedule:Compact, ACTIVITY_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,120.; !- Field 3 Schedule:Compact, WORK_EFF_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, AIR_VELO_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, CLOTHING_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 04/30, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0, !- Field 3 Through: 09/30, !- Field 5 For: AllDays, !- Field 6 Until: 24:00,0.5, !- Field 7 Through: 12/31, !- Field 9 For: AllDays, !- Field 10 Until: 24:00,1.0; !- Field 11 Schedule:Compact, INFIL_SCH, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 06:00,1.0, !- Field 3 Until: 22:00,0.0, !- Field 5 Until: 24:00,1.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 06:00,1.0, !- Field 10 Until: 18:00,0.0, !- Field 12 Until: 24:00,1.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,1.0; !- Field 17 Schedule:Compact, INFIL_SCH_PNNL, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 06:00,1.0, !- Field 3 Until: 22:00,0.25, !- Field 5 Until: 24:00,1.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 06:00,1.0, !- Field 10 Until: 18:00,0.25, !- Field 12 Until: 24:00,1.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,1.0; !- Field 17 Schedule:Compact, INFIL_HALF_ON_SCH, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 06:00,1.0, !- Field 3 Until: 22:00,0.5, !- Field 5 Until: 24:00,1.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 06:00,1.0, !- Field 10 Until: 18:00,0.5, !- Field 12 Until: 24:00,1.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,1.0; !- Field 17 Schedule:Compact, SHADING_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, PlantOnSched, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, FAN_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, ReheatCoilAvailSched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, CoolingCoilAvailSched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, HTGSETP_SCH_YES_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WinterDesignDay, !- Field 2 Until: 05:00,15.6, !- Field 3 Until: 06:00,17.6, !- Field 5 Until: 07:00,19.6, !- Field 7 Until: 22:00,21.0, !- Field 9 Until: 24:00,15.6, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,15.6, !- Field 14 Until: 05:00,17.8, !- Field 16 Until: 06:00,20.0, !- Field 18 Until: 22:00,21.0, !- Field 20 Until: 24:00,15.6, !- Field 22 For SummerDesignDay, !- Field 24 Until: 24:00,15.6, !- Field 25 For: Saturday, !- Field 27 Until: 04:00,15.6, !- Field 28 Until: 05:00,17.8, !- Field 30 Until: 06:00,20.0, !- Field 32 Until: 17:00,21.0, !- Field 34 Until: 24:00,15.6, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,15.6; !- Field 39 Schedule:Compact, HTGSETP_SCH_YES_OPTIMUM_w_SB, !-Name Temperature, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 15.6, Until: 02:00, 15.6, Until: 03:00, 15.6, Until: 04:00, 15.6, Until: 05:00, 17.8, Until: 06:00, 20, Until: 07:00, 21, Until: 08:00, 21, Until: 09:00, 21, Until: 10:00, 21, Until: 11:00, 20.4444444444444, Until: 12:00, 21, Until: 13:00, 20.4444444444444, Until: 14:00, 21, Until: 15:00, 20.4444444444444, Until: 16:00, 21, Until: 17:00, 21, Until: 18:00, 21, Until: 19:00, 21, Until: 20:00, 21, Until: 21:00, 21, Until: 22:00, 21, Until: 23:00, 15.6, Until: 24:00, 15.6, For: Saturday, Until: 01:00, 15.6, Until: 02:00, 15.6, Until: 03:00, 15.6, Until: 04:00, 15.6, Until: 05:00, 17.8, Until: 06:00, 20, Until: 07:00, 21, Until: 08:00, 21, Until: 09:00, 21, Until: 10:00, 21, Until: 11:00, 20.4444444444444, Until: 12:00, 21, Until: 13:00, 20.4444444444444, Until: 14:00, 21, Until: 15:00, 20.4444444444444, Until: 16:00, 21, Until: 17:00, 21, Until: 18:00, 15.6, Until: 19:00, 15.6, Until: 20:00, 15.6, Until: 21:00, 15.6, Until: 22:00, 15.6, Until: 23:00, 15.6, Until: 24:00, 15.6, For: WinterDesignDay, Until: 05:00,15.6, Until: 06:00,17.6, Until: 07:00,19.6, Until: 22:00,21.0, Until: 24:00,15.6, For SummerDesignDay, Until: 24:00,15.6, For:Sunday Holidays AllOtherDays, Until: 24:00,15.6; Schedule:Compact, HTGSETP_SCH_YES_OPTIMUM_original, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WinterDesignDay, !- Field 2 Until: 05:00,15.6, !- Field 3 Until: 06:00,17.6, !- Field 5 Until: 07:00,19.6, !- Field 7 Until: 22:00,21.0, !- Field 9 Until: 24:00,15.6, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,15.6, !- Field 14 Until: 05:00,17.8, !- Field 16 Until: 06:00,20.0, !- Field 18 Until: 22:00,21.0, !- Field 20 Until: 24:00,15.6, !- Field 22 For SummerDesignDay, !- Field 24 Until: 24:00,15.6, !- Field 25 For: Saturday, !- Field 27 Until: 04:00,15.6, !- Field 28 Until: 05:00,17.8, !- Field 30 Until: 06:00,20.0, !- Field 32 Until: 17:00,21.0, !- Field 34 Until: 24:00,15.6, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,15.6; !- Field 39 Schedule:Compact, HTGSETP_SCH_NO_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WinterDesignDay, !- Field 2 Until: 05:00,15.6, !- Field 3 Until: 06:00,17.6, !- Field 5 Until: 07:00,19.6, !- Field 7 Until: 22:00,21.0, !- Field 9 Until: 24:00,15.6, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,15.6, !- Field 14 Until: 05:00,21.0, !- Field 16 Until: 06:00,21.0, !- Field 18 Until: 22:00,21.0, !- Field 20 Until: 24:00,15.6, !- Field 22 For SummerDesignDay, !- Field 24 Until: 24:00,15.6, !- Field 25 For: Saturday, !- Field 27 Until: 04:00,15.6, !- Field 28 Until: 05:00,21.0, !- Field 30 Until: 06:00,21.0, !- Field 32 Until: 17:00,21.0, !- Field 34 Until: 24:00,15.6, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,15.6; !- Field 39 Schedule:Compact, HTGSETP_SCH_CAV_bas, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WinterDesignDay, !- Field 2 Until: 05:00,15.6, !- Field 3 Until: 06:00,17.6, !- Field 5 Until: 07:00,19.6, !- Field 7 Until: 22:00,21.0, !- Field 9 Until: 24:00,15.6, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,15.6, !- Field 14 Until: 05:00,21.0, !- Field 16 Until: 06:00,21.0, !- Field 18 Until: 22:00,21.0, !- Field 20 Until: 24:00,15.6, !- Field 22 For SummerDesignDay, !- Field 24 Until: 24:00,15.6, !- Field 25 For: Saturday, !- Field 27 Until: 04:00,15.6, !- Field 28 Until: 05:00,21.0, !- Field 30 Until: 06:00,21.0, !- Field 32 Until: 17:00,21.0, !- Field 34 Until: 24:00,15.6, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,15.6; !- Field 39 Schedule:Compact, CLGSETP_SCH_YES_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 05:00,26.7, !- Field 3 Until: 06:00,25.7, !- Field 5 Until: 07:00,25.0, !- Field 7 Until: 22:00,24.0, !- Field 9 Until: 24:00,26.7, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,26.7, !- Field 14 Until: 05:00,25.6, !- Field 16 Until: 06:00,25.0, !- Field 18 Until: 22:00,24.0, !- Field 20 Until: 24:00,26.7, !- Field 22 For: Saturday, !- Field 24 Until: 04:00,26.7, !- Field 25 Until: 05:00,25.6, !- Field 27 Until: 06:00,25.0, !- Field 29 Until: 17:00,24.0, !- Field 31 Until: 24:00,26.7, !- Field 33 For WinterDesignDay, !- Field 35 Until: 24:00,26.7, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,26.7; !- Field 39 Schedule:Compact, CLGSETP_SCH_YES_OPTIMUM_w_SB, !-Name Temperature, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 26.7, Until: 02:00, 26.7, Until: 03:00, 26.7, Until: 04:00, 26.7, Until: 05:00, 25.6, Until: 06:00, 25, Until: 07:00, 24, Until: 08:00, 24, Until: 09:00, 24, Until: 10:00, 24, Until: 11:00, 24.5555555555556, Until: 12:00, 24, Until: 13:00, 24.5555555555556, Until: 14:00, 24, Until: 15:00, 24.5555555555556, Until: 16:00, 24, Until: 17:00, 24, Until: 18:00, 24, Until: 19:00, 24, Until: 20:00, 24, Until: 21:00, 24, Until: 22:00, 24, Until: 23:00, 26.7, Until: 24:00, 26.7, For: Saturday, Until: 01:00, 26.7, Until: 02:00, 26.7, Until: 03:00, 26.7, Until: 04:00, 26.7, Until: 05:00, 25.6, Until: 06:00, 25, Until: 07:00, 24, Until: 08:00, 24, Until: 09:00, 24, Until: 10:00, 24, Until: 11:00, 24.5555555555556, Until: 12:00, 24, Until: 13:00, 24.5555555555556, Until: 14:00, 24, Until: 15:00, 24.5555555555556, Until: 16:00, 24, Until: 17:00, 24, Until: 18:00, 26.7, Until: 19:00, 26.7, Until: 20:00, 26.7, Until: 21:00, 26.7, Until: 22:00, 26.7, Until: 23:00, 26.7, Until: 24:00, 26.7, For: SummerDesignDay, Until: 05:00,26.7, Until: 06:00,25.7, Until: 07:00,25.0, Until: 22:00,24.0, Until: 24:00,26.7, For WinterDesignDay, Until: 24:00,26.7, For:Sunday Holidays AllOtherDays, Until: 24:00,26.7; Schedule:Compact, CLGSETP_SCH_YES_OPTIMUM_original, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 05:00,26.7, !- Field 3 Until: 06:00,25.7, !- Field 5 Until: 07:00,25.0, !- Field 7 Until: 22:00,24.0, !- Field 9 Until: 24:00,26.7, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,26.7, !- Field 14 Until: 05:00,25.6, !- Field 16 Until: 06:00,25.0, !- Field 18 Until: 22:00,24.0, !- Field 20 Until: 24:00,26.7, !- Field 22 For: Saturday, !- Field 24 Until: 04:00,26.7, !- Field 25 Until: 05:00,25.6, !- Field 27 Until: 06:00,25.0, !- Field 29 Until: 17:00,24.0, !- Field 31 Until: 24:00,26.7, !- Field 33 For WinterDesignDay, !- Field 35 Until: 24:00,26.7, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,26.7; !- Field 39 Schedule:Compact, CLGSETP_SCH_NO_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 05:00,26.7, !- Field 3 Until: 06:00,25.7, !- Field 5 Until: 07:00,25.0, !- Field 7 Until: 22:00,24.0, !- Field 9 Until: 24:00,26.7, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,26.7, !- Field 14 Until: 05:00,24.0, !- Field 16 Until: 06:00,24.0, !- Field 18 Until: 22:00,24.0, !- Field 20 Until: 24:00,26.7, !- Field 22 For: Saturday, !- Field 24 Until: 04:00,26.7, !- Field 25 Until: 05:00,24.0, !- Field 27 Until: 06:00,24.0, !- Field 29 Until: 17:00,24.0, !- Field 31 Until: 24:00,26.7, !- Field 33 For WinterDesignDay, !- Field 35 Until: 24:00,26.7, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,26.7; !- Field 39 Schedule:Compact, CLGSETP_SCH_NO_SETBACK, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 05:00,26.7, !- Field 3 Until: 06:00,25.7, !- Field 5 Until: 07:00,25.0, !- Field 7 Until: 22:00,24.0, !- Field 9 Until: 24:00,26.7, !- Field 11 For: Weekdays, !- Field 13 Until: 05:00,24.0, !- Field 14 Until: 06:00,24.0, !- Field 16 Until: 07:00,24.0, !- Field 18 Until: 22:00,24.0, !- Field 20 Until: 24:00,24.0, !- Field 22 For: Saturday, !- Field 24 Until: 05:00,24.0, !- Field 25 Until: 06:00,24.0, !- Field 27 Until: 07:00,24.0, !- Field 29 Until: 17:00,24.0, !- Field 31 Until: 24:00,24.0, !- Field 33 For WinterDesignDay, !- Field 35 Until: 24:00,24.0, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,24.0; !- Field 39 Schedule:Compact, CLGSETP_SCH_CAV_bas, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: SummerDesignDay, !- Field 2 Until: 05:00,26.7, !- Field 3 Until: 06:00,25.7, !- Field 5 Until: 07:00,25.0, !- Field 7 Until: 22:00,24.0, !- Field 9 Until: 24:00,26.7, !- Field 11 For: Weekdays, !- Field 13 Until: 04:00,26.7, !- Field 14 Until: 05:00,24.0, !- Field 16 Until: 06:00,24.0, !- Field 18 Until: 22:00,24.0, !- Field 20 Until: 24:00,26.7, !- Field 22 For: Saturday, !- Field 24 Until: 04:00,26.7, !- Field 25 Until: 05:00,24.0, !- Field 27 Until: 06:00,24.0, !- Field 29 Until: 17:00,24.0, !- Field 31 Until: 24:00,26.7, !- Field 33 For WinterDesignDay, !- Field 35 Until: 24:00,26.7, !- Field 36 For: Sunday Holidays AllOtherDays, !- Field 38 Until: 24:00,26.7; !- Field 39 Schedule:Compact, MinOA_MotorizedDamper_Sched, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 07:00,0.0, !- Field 3 Until: 22:00,1.0, !- Field 5 Until: 24:00,0.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 07:00,0.0, !- Field 10 Until: 18:00,1.0, !- Field 12 Until: 24:00,0.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,0.0; !- Field 17 Schedule:Compact, MinOA_Sched, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, Dual Zone Control Type Sched, !- Name Control Type, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,4; !- Field 3 Schedule:Compact, Cool-Supply-Air-Temp-Sch,!- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,12.8; !- Field 3 Schedule:Compact, Heat-Supply-Air-Temp-Sch,!- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,12.8; !- Field 3 Schedule:Compact, CW-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,6.7; !- Field 3 Schedule:Compact, HW-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,82; !- Field 3 !- Per 90.1-2010 G3.1.3.11, the tower shall be controlled to maintain a 70F leaving water temperature !- where weather permits, floating up to leaving water temperature at design conditions. Schedule:Compact, Tower-Loop-Temp-Schedule,!- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,21.1; !- Field 3 Schedule:Compact, Core_bottom sub cat Latent fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.05; !- Field 3 Schedule:Compact, Core_bottom sub cat Sensible fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, Core_bottom sub cat Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.0; !- Field 3 Schedule:Compact, Core_bottom sub catHot Supply Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,55; !- Field 3 Schedule:Compact, Core_mid sub cat Latent fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.05; !- Field 3 Schedule:Compact, Core_mid sub cat Sensible fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, Core_mid sub cat Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.0; !- Field 3 Schedule:Compact, Core_mid sub catHot Supply Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,55; !- Field 3 Schedule:Compact, Core_top sub cat Latent fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.05; !- Field 3 Schedule:Compact, Core_top sub cat Sensible fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, Core_top sub cat Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.0; !- Field 3 Schedule:Compact, Core_top sub catHot Supply Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,55; !- Field 3 Schedule:Compact, SHWSys1-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60; !- Field 3 Schedule:Compact, SHWSys1 Water Heater Setpoint Temperature Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.0; !- Field 3 Schedule:Compact, SHWSys1 Water Heater Ambient Temperature Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,22.0; !- Field 3 Schedule:Compact, CLGSETP_DC_SCH, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR SummerDesignDay, !- Field 2 UNTIL: 24:00,27, !- Field 3 FOR WinterDesignDay, !- Field 5 UNTIL: 24:00,27, !- Field 6 FOR:AllOtherDays, !- Field 8 UNTIL: 24:00,27; !- Field 9 Schedule:Compact, HTGSETP_DC_SCH, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:AllDays, !- Field 2 UNTIL: 24:00,18; !- Field 3 Schedule:Compact, PLANT LOOP HIGH TEMP SCHEDULE, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Alldays, !- Field 2 Until: 24:00,18.33; !- Field 3 Schedule:Compact, PLANT LOOP LOW TEMP SCHEDULE, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Alldays, !- Field 2 Until: 24:00,5; !- Field 3 Schedule:Compact, SupplyFanSch, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 Schedule:Compact, DC_MinRelHumSetSch, !- Name Humidity, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,30; !- Field 3 Schedule:Compact, PERIMETER_MID_ZN_2_MDP_Sch, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0.097, Until: 02:00, 0.097, Until: 03:00, 0.097, Until: 04:00, 0.097, Until: 05:00, 0.097, Until: 06:00, 0.097, Until: 07:00, 0.097, Until: 08:00, 0.097, Until: 09:00, 0.097, Until: 10:00, 0.097, Until: 11:00, 0, Until: 12:00, 0.097, Until: 13:00, 0, Until: 14:00, 0.097, Until: 15:00, 0, Until: 16:00, 0.097, Until: 17:00, 0.097, Until: 18:00, 0.097, Until: 19:00, 0.097, Until: 20:00, 0.097, Until: 21:00, 0.097, Until: 22:00, 0.097, Until: 23:00, 0.097, Until: 24:00, 0.097, For: Saturday, Until: 01:00, 0.097, Until: 02:00, 0.097, Until: 03:00, 0.097, Until: 04:00, 0.097, Until: 05:00, 0.097, Until: 06:00, 0.097, Until: 07:00, 0.097, Until: 08:00, 0.097, Until: 09:00, 0.097, Until: 10:00, 0.097, Until: 11:00, 0, Until: 12:00, 0.097, Until: 13:00, 0, Until: 14:00, 0.097, Until: 15:00, 0, Until: 16:00, 0.097, Until: 17:00, 0.097, Until: 18:00, 0.097, Until: 19:00, 0.097, Until: 20:00, 0.097, Until: 21:00, 0.097, Until: 22:00, 0.097, Until: 23:00, 0.097, Until: 24:00, 0.097, For: AllOtherDays, Until: 24:00, 0.097; Schedule:Constant, VAV_BOT WITH REHEAT Max OA Fraction, !- Name , !- Schedule Type Limits Name 1.0; !- Hourly Value Schedule:Constant, VAV_MID WITH REHEAT Max OA Fraction, !- Name , !- Schedule Type Limits Name 1.0; !- Hourly Value Schedule:Constant, VAV_TOP WITH REHEAT Max OA Fraction, !- Name , !- Schedule Type Limits Name 1.0; !- Hourly Value !- =========== ALL OBJECTS IN CLASS: PEOPLE =========== People, Basement, !- Name Basement, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Core_bottom, !- Name Core_bottom, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Core_mid, !- Name Core_mid, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Core_top, !- Name Core_top, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_bot_ZN_3, !- Name Perimeter_bot_ZN_3, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_bot_ZN_2, !- Name Perimeter_bot_ZN_2, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_bot_ZN_1, !- Name Perimeter_bot_ZN_1, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_bot_ZN_4, !- Name Perimeter_bot_ZN_4, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_mid_ZN_3, !- Name Perimeter_mid_ZN_3, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_mid_ZN_2, !- Name Perimeter_mid_ZN_2, !- Zone or ZoneList Name BLDG_OCC_SCH_w_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_mid_ZN_1, !- Name Perimeter_mid_ZN_1, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_mid_ZN_4, !- Name Perimeter_mid_ZN_4, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_top_ZN_3, !- Name Perimeter_top_ZN_3, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_top_ZN_2, !- Name Perimeter_top_ZN_2, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_top_ZN_1, !- Name Perimeter_top_ZN_1, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, Perimeter_top_ZN_4, !- Name Perimeter_top_ZN_4, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 18.5787942465724, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type !- =========== ALL OBJECTS IN CLASS: LIGHTS =========== Lights, Basement_Lights, !- Name Basement, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Core_bottom_Lights, !- Name Core_bottom, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Core_mid_Lights, !- Name Core_mid, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Core_top_Lights, !- Name Core_top, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_bot_ZN_3_Lights, !- Name Perimeter_bot_ZN_3, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_bot_ZN_2_Lights, !- Name Perimeter_bot_ZN_2, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_bot_ZN_1_Lights, !- Name Perimeter_bot_ZN_1, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_bot_ZN_4_Lights, !- Name Perimeter_bot_ZN_4, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_mid_ZN_3_Lights, !- Name Perimeter_mid_ZN_3, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_mid_ZN_2_Lights, !- Name Perimeter_mid_ZN_2, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_mid_ZN_1_Lights, !- Name Perimeter_mid_ZN_1, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_mid_ZN_4_Lights, !- Name Perimeter_mid_ZN_4, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_top_ZN_3_Lights, !- Name Perimeter_top_ZN_3, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_top_ZN_2_Lights, !- Name Perimeter_top_ZN_2, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_top_ZN_1_Lights, !- Name Perimeter_top_ZN_1, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_top_ZN_4_Lights, !- Name Perimeter_top_ZN_4, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, DataCenter_Basement_Lights, !- Name DataCenter_basement_ZN_6,!- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, DataCenter_bot_Lights, !- Name DataCenter_bot_ZN_6, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, DataCenter_mid_Lights, !- Name DataCenter_mid_ZN_6, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, DataCenter_top_Lights, !- Name DataCenter_top_ZN_6, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature !- =========== ALL OBJECTS IN CLASS: ELECTRIC EQUIPMENT =========== ElectricEquipment, Basement_MiscPlug_Equip, !- Name Basement, !- Zone or ZoneList Name Always_on, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 13457.544, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Core_bottom_MiscPlug_Equip, !- Name Core_bottom, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 20142.877, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Core_mid_MiscPlug_Equip, !- Name Core_mid, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 20142.8, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Core_top_MiscPlug_Equip, !- Name Core_top, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 20142.8, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_bot_ZN_3_MiscPlug_Equip, !- Name Perimeter_bot_ZN_3, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 2529.2421, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_bot_ZN_2_MiscPlug_Equip, !- Name Perimeter_bot_ZN_2, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 1629.9400, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_bot_ZN_1_MiscPlug_Equip, !- Name Perimeter_bot_ZN_1, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 2529.2809, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_bot_ZN_4_MiscPlug_Equip, !- Name Perimeter_bot_ZN_4, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 1629.9293, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_mid_ZN_3_MiscPlug_Equip, !- Name Perimeter_mid_ZN_3, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 2529.2421, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_mid_ZN_2_MiscPlug_Equip, !- Name Perimeter_mid_ZN_2, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 1629.9400, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_mid_ZN_1_MiscPlug_Equip, !- Name Perimeter_mid_ZN_1, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 2529.2809, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_mid_ZN_4_MiscPlug_Equip, !- Name Perimeter_mid_ZN_4, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 1629.9293, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_top_ZN_3_MiscPlug_Equip, !- Name Perimeter_top_ZN_3, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 2529.2421, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_top_ZN_2_MiscPlug_Equip, !- Name Perimeter_top_ZN_2, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 1629.9400, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_top_ZN_1_MiscPlug_Equip, !- Name Perimeter_top_ZN_1, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 2529.2809, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_top_ZN_4_MiscPlug_Equip, !- Name Perimeter_top_ZN_4, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 1629.9293, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, DataCenter_Basement_MiscPlug_Equip, !- Name DataCenter_basement_ZN_6,!- Zone or ZoneList Name DataCenter_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method 0, !- Design Level {W} 484.423246742185, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.1000, !- Fraction Radiant 0.0000, !- Fraction Lost DataCenterPlugLoads; !- End-Use Subcategory ElectricEquipment, DataCenter_bot_MiscPlug_Equip, !- Name DataCenter_bot_ZN_6, !- Zone or ZoneList Name DataCenter_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method 0, !- Design Level {W} 215.299220774304, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.1000, !- Fraction Radiant 0.0000, !- Fraction Lost DataCenterPlugLoads; !- End-Use Subcategory ElectricEquipment, DataCenter_mid_MiscPlug_Equip, !- Name DataCenter_mid_ZN_6, !- Zone or ZoneList Name DataCenter_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method 0, !- Design Level {W} 215.299220774304, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.1000, !- Fraction Radiant 0.0000, !- Fraction Lost DataCenterPlugLoads; !- End-Use Subcategory ElectricEquipment, DataCenter_top_MiscPlug_Equip, !- Name DataCenter_top_ZN_6, !- Zone or ZoneList Name DataCenter_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method 0, !- Design Level {W} 215.299220774304, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.1000, !- Fraction Radiant 0.0000, !- Fraction Lost DataCenterPlugLoads; !- End-Use Subcategory Exterior:FuelEquipment, Elevators, !- Name Electricity, !- Fuel Use Type BLDG_ELEVATORS, !- Schedule Name 244443.956043956, !- Design Level {W} ElevatorLift; !- End-Use Subcategory Exterior:FuelEquipment, Elevators_Lights_Fan, !- Name Electricity, !- Fuel Use Type ELEV_LIGHT_FAN_SCH_ADD_DF, !- Schedule Name 752, !- Design Level {W} ElevatorLightsFan; !- End-Use Subcategory !- =========== ALL OBJECTS IN CLASS: EXTERIORLIGHTS =========== Exterior:Lights, Exterior_Lights_a, !- Name Exterior_lighting_schedule_a, !- Schedule Name 12979.2, !- Design Level {W} AstronomicalClock, !- Control Option General; !- End-Use Subcategory Exterior:Lights, Exterior_Lights_b, !- Name Exterior_lighting_schedule_b_2016, !- Schedule Name 968, !- Design Level {W} AstronomicalClock, !- Control Option General; !- End-Use Subcategory Exterior:Lights, Exterior_Lights_c, !- Name Exterior_lighting_schedule_c_2016, !- Schedule Name 26027, !- Design Level {W} AstronomicalClock, !- Control Option General; !- End-Use Subcategory !- =========== ALL OBJECTS IN CLASS: DAYLIGHTING:DETAILED =========== Daylighting:Controls, Perimeter_bot_ZN_1_DaylCtrl, !- Name Perimeter_bot_ZN_1, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_bot_ZN_1_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 180.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_bot_ZN_1_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_bot_ZN_1_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_bot_ZN_1_DaylRefPt1, !- Name Perimeter_bot_ZN_1, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 1.676400, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_bot_ZN_1_DaylRefPt2, !- Name Perimeter_bot_ZN_1, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 3.352800, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_bot_ZN_2_DaylCtrl, !- Name Perimeter_bot_ZN_2, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_bot_ZN_2_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 90.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_bot_ZN_2_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_bot_ZN_2_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_bot_ZN_2_DaylRefPt1, !- Name Perimeter_bot_ZN_2, !- Zone Name 71.430800, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_bot_ZN_2_DaylRefPt2, !- Name Perimeter_bot_ZN_2, !- Zone Name 69.754400, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_bot_ZN_3_DaylCtrl, !- Name Perimeter_bot_ZN_3, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_bot_ZN_3_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 0.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_bot_ZN_3_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_bot_ZN_3_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_bot_ZN_3_DaylRefPt1, !- Name Perimeter_bot_ZN_3, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 47.061700, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_bot_ZN_3_DaylRefPt2, !- Name Perimeter_bot_ZN_3, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 45.384700, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_bot_ZN_4_DaylCtrl, !- Name Perimeter_bot_ZN_4, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_bot_ZN_4_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 270.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_bot_ZN_4_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_bot_ZN_4_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_bot_ZN_4_DaylRefPt1, !- Name Perimeter_bot_ZN_4, !- Zone Name 1.676400, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_bot_ZN_4_DaylRefPt2, !- Name Perimeter_bot_ZN_4, !- Zone Name 3.352800, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_mid_ZN_1_DaylCtrl, !- Name Perimeter_mid_ZN_1, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_mid_ZN_1_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 180.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_mid_ZN_1_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_mid_ZN_1_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_mid_ZN_1_DaylRefPt1, !- Name Perimeter_mid_ZN_1, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 1.676400, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_mid_ZN_1_DaylRefPt2, !- Name Perimeter_mid_ZN_1, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 3.352800, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_mid_ZN_2_DaylCtrl, !- Name Perimeter_mid_ZN_2, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_mid_ZN_2_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 90.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_mid_ZN_2_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_mid_ZN_2_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_mid_ZN_2_DaylRefPt1, !- Name Perimeter_mid_ZN_2, !- Zone Name 71.430800, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_mid_ZN_2_DaylRefPt2, !- Name Perimeter_mid_ZN_2, !- Zone Name 69.754400, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_mid_ZN_3_DaylCtrl, !- Name Perimeter_mid_ZN_3, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_mid_ZN_3_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 0.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_mid_ZN_3_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_mid_ZN_3_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_mid_ZN_3_DaylRefPt1, !- Name Perimeter_mid_ZN_3, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 47.061700, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_mid_ZN_3_DaylRefPt2, !- Name Perimeter_mid_ZN_3, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 45.384700, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_mid_ZN_4_DaylCtrl, !- Name Perimeter_mid_ZN_4, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_mid_ZN_4_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 270.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_mid_ZN_4_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_mid_ZN_4_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_mid_ZN_4_DaylRefPt1, !- Name Perimeter_mid_ZN_4, !- Zone Name 1.676400, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_mid_ZN_4_DaylRefPt2, !- Name Perimeter_mid_ZN_4, !- Zone Name 3.352800, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 17.526000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_top_ZN_1_DaylCtrl, !- Name Perimeter_top_ZN_1, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_top_ZN_1_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 180.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_top_ZN_1_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_top_ZN_1_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_top_ZN_1_DaylRefPt1, !- Name Perimeter_top_ZN_1, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 1.676400, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_top_ZN_1_DaylRefPt2, !- Name Perimeter_top_ZN_1, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 3.352800, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_top_ZN_2_DaylCtrl, !- Name Perimeter_top_ZN_2, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_top_ZN_2_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 90.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_top_ZN_2_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_top_ZN_2_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_top_ZN_2_DaylRefPt1, !- Name Perimeter_top_ZN_2, !- Zone Name 71.430800, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_top_ZN_2_DaylRefPt2, !- Name Perimeter_top_ZN_2, !- Zone Name 69.754400, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_top_ZN_3_DaylCtrl, !- Name Perimeter_top_ZN_3, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_top_ZN_3_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 0.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_top_ZN_3_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_top_ZN_3_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_top_ZN_3_DaylRefPt1, !- Name Perimeter_top_ZN_3, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 47.061700, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_top_ZN_3_DaylRefPt2, !- Name Perimeter_top_ZN_3, !- Zone Name 36.576000, !- X-Coordinate of Reference Point {m} 45.384700, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_top_ZN_4_DaylCtrl, !- Name Perimeter_top_ZN_4, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_top_ZN_4_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 270.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_top_ZN_4_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.3857, !- Fraction of Zone Controlled by Reference Point 1 377.0, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_top_ZN_4_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.1385, !- Fraction of Zone Controlled by Reference Point 2 377.0; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_top_ZN_4_DaylRefPt1, !- Name Perimeter_top_ZN_4, !- Zone Name 1.676400, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_top_ZN_4_DaylRefPt2, !- Name Perimeter_top_ZN_4, !- Zone Name 3.352800, !- X-Coordinate of Reference Point {m} 24.384000, !- Y-Coordinate of Reference Point {m} 34.290000; !- Z-Coordinate of Reference Point {m} !- =========== ALL OBJECTS IN CLASS: INFILTRATION =========== ZoneInfiltration:DesignFlowRate, Perimeter_bot_ZN_3_Infiltration, !- Name Perimeter_bot_ZN_3, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_bot_ZN_2_Infiltration, !- Name Perimeter_bot_ZN_2, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_bot_ZN_1_Infiltration, !- Name Perimeter_bot_ZN_1, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_bot_ZN_4_Infiltration, !- Name Perimeter_bot_ZN_4, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_mid_ZN_3_Infiltration, !- Name Perimeter_mid_ZN_3, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_mid_ZN_2_Infiltration, !- Name Perimeter_mid_ZN_2, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_mid_ZN_1_Infiltration, !- Name Perimeter_mid_ZN_1, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_mid_ZN_4_Infiltration, !- Name Perimeter_mid_ZN_4, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_top_ZN_3_Infiltration, !- Name Perimeter_top_ZN_3, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_top_ZN_2_Infiltration, !- Name Perimeter_top_ZN_2, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_top_ZN_1_Infiltration, !- Name Perimeter_top_ZN_1, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_top_ZN_4_Infiltration, !- Name Perimeter_top_ZN_4, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, GroundFloor_Plenum_Infiltration, !- Name GroundFloor_Plenum, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, MidFloor_Plenum_Infiltration, !- Name MidFloor_Plenum, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, TopFloor_Plenum_Infiltration, !- Name TopFloor_Plenum, !- Zone or ZoneList Name INFIL_SCH_PNNL, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 4.37644032e-05, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient !- =========== ALL OBJECTS IN CLASS: SIZING PARAMETERS =========== Sizing:Parameters, 1, !- Heating Sizing Factor 1, !- Cooling Sizing Factor 6; !- Timesteps in Averaging Window !- =========== ALL OBJECTS IN CLASS: ZONE SIZING =========== Sizing:Zone, Basement, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Basement, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} ; !- Heating Maximum Air Flow Fraction DesignSpecification:OutdoorAir, SZ DSOA Basement, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Core_bottom, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Core_bottom, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Core_bottom, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Core_mid, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Core_mid, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Core_mid, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Core_top, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Core_top, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Core_top, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_bot_ZN_3, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_bot_ZN_3, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_bot_ZN_3, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_bot_ZN_2, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_bot_ZN_2, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_bot_ZN_2, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_bot_ZN_1, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_bot_ZN_1, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_bot_ZN_1, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_bot_ZN_4, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_bot_ZN_4, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_bot_ZN_4, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_mid_ZN_3, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_mid_ZN_3, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_mid_ZN_3, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_mid_ZN_2, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_mid_ZN_2, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_mid_ZN_2, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_mid_ZN_1, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_mid_ZN_1, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_mid_ZN_1, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_mid_ZN_4, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_mid_ZN_4, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_mid_ZN_4, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_top_ZN_3, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_top_ZN_3, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_top_ZN_3, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_top_ZN_2, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_top_ZN_2, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_top_ZN_2, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_top_ZN_1, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_top_ZN_1, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_top_ZN_1, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_top_ZN_4, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_top_ZN_4, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction VAV_Zone_AirDistribution;!- Design Specification Zone Air Distribution Object Name DesignSpecification:OutdoorAir, SZ DSOA Perimeter_top_ZN_4, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, DataCenter_basement_ZN_6,!- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA DataCenter_basement_ZN_6, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} ; !- Heating Maximum Air Flow {m3/s} DesignSpecification:OutdoorAir, SZ DSOA DataCenter_basement_ZN_6, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, DataCenter_bot_ZN_6, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA DataCenter_bot_ZN_6, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} ; !- Heating Maximum Air Flow {m3/s} DesignSpecification:OutdoorAir, SZ DSOA DataCenter_bot_ZN_6, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, DataCenter_mid_ZN_6, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA DataCenter_mid_ZN_6, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} ; !- Heating Maximum Air Flow {m3/s} DesignSpecification:OutdoorAir, SZ DSOA DataCenter_mid_ZN_6, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, DataCenter_top_ZN_6, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA DataCenter_top_ZN_6, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} ; !- Heating Maximum Air Flow {m3/s} DesignSpecification:OutdoorAir, SZ DSOA DataCenter_top_ZN_6, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} DesignSpecification:ZoneAirDistribution, VAV_Zone_AirDistribution, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} , !- Zone Air Distribution Effectiveness Schedule Name , !- Zone Secondary Recirculation Fraction {dimensionless} 0.6; !- Minimum Zone Ventilation Efficiency {dimensionless} !- =========== ALL OBJECTS IN CLASS: SYSTEM SIZING =========== Sizing:System, CAV_bas, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.00, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 40.0000, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, VAV_bot WITH REHEAT, !- AirLoop Name Sensible, !- Type of Load to Size On 2.0304, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 12.8000, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, VAV_mid WITH REHEAT, !- AirLoop Name Sensible, !- Type of Load to Size On 20.304, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 12.8000, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, VAV_top WITH REHEAT, !- AirLoop Name Sensible, !- Type of Load to Size On 2.0304, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 12.8000, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, AirLoop DataCenter Basement, !- AirLoop Name Sensible, !- Type of Load to Size On autosize, !- Design Outdoor Air Flow Rate {m3/s} 1, !- Central Heating Maximum System Air Flow Ratio 7, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Central Cooling Design Supply Air Temperature {C} 40, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, AirLoop DataCenter bot, !- AirLoop Name Sensible, !- Type of Load to Size On autosize, !- Design Outdoor Air Flow Rate {m3/s} 1, !- Central Heating Maximum System Air Flow Ratio 7, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Central Cooling Design Supply Air Temperature {C} 40, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, AirLoop DataCenter mid, !- AirLoop Name Sensible, !- Type of Load to Size On autosize, !- Design Outdoor Air Flow Rate {m3/s} 1, !- Central Heating Maximum System Air Flow Ratio 7, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Central Cooling Design Supply Air Temperature {C} 40, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, AirLoop DataCenter top, !- AirLoop Name Sensible, !- Type of Load to Size On autosize, !- Design Outdoor Air Flow Rate {m3/s} 1, !- Central Heating Maximum System Air Flow Ratio 7, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8, !- Central Cooling Design Supply Air Temperature {C} 40, !- Central Heating Design Supply Air Temperature {C} Coincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method !- =========== ALL OBJECTS IN CLASS: PLANT SIZING =========== Sizing:Plant, SHWSys1, !- Plant or Condenser Loop Name Heating, !- Loop Type 60, !- Design Loop Exit Temperature {C} 5.0; !- Loop Design Temperature Difference {deltaC} Sizing:Plant, HeatSys1, !- Plant or Condenser Loop Name Heating, !- Loop Type 82.0, !- Design Loop Exit Temperature {C} 11.0; !- Loop Design Temperature Difference {deltaC} Sizing:Plant, CoolSys1_Supply, !- Plant or Condenser Loop Name Cooling, !- Loop Type 6.67, !- Design Loop Exit Temperature {C} 8.33; !- Loop Design Temperature Difference {deltaC} Sizing:Plant, CoolSys1_Demand, !- Plant or Condenser Loop Name Cooling, !- Loop Type 6.67, !- Design Loop Exit Temperature {C} 8.33; !- Loop Design Temperature Difference {deltaC} !- Design Loop Exit Temperature: Per 90.1-2010 G3.1.3.13, condenser water design supply temperature shall be !- 85F or 10F approaching design wet-bulb temperature, whichever is lower, with a design temperature rise of 10F (range temperature). !- Loop Design Temperature Difference: Per 90.1-2010 G3.1.3.13, design temperature rise of 10F (range temperature). !- Sizing Option: new inputs after V8.3. We choose coincident to be aligned with system sizing. Default (leaving blank) is noncoincident. !- Zone Timesteps in Averaging Window: alignment with system inputs for Timesteps in Averaging Window. !- Coincident Sizing Factor Mode: GlobalCoolingSizingFactor aligns with the system level sizing parameter inputs. Sizing:Plant, TowerWaterSys, !- Plant or Condenser Loop Name Condenser, !- Loop Type 29.4444444444444, !- Design Loop Exit Temperature {C} 5.55555555555556, !- Loop Design Temperature Difference {deltaC} Coincident, !- Sizing Option 6, !- Zone Timesteps in Averaging Window GlobalCoolingSizingFactor; !- Coincident Sizing Factor Mode !- Plant loop for dry cooler and boiler for Data Center Sizing:Plant, Single Water Plant Loop, !- Plant or Condenser Loop Name Heating, !- Loop Type 39, !- Design Loop Exit Temperature {C} 11; !- Loop Design Temperature Difference {deltaC} !- Set of chiller curves based on Dick Lord's study dated January 17, 2010... !- Hospital and Large Office have water cooled chillers...Hence set of water cooled chillers to be used in these prototypes... !- Large Office will follow 90.1-2010 Path B in the PI case whereas Hospital will follow Path A based on the discussion with the SWG !- Changed the min. chiller condenser fluid entering temperature to 64 F (17.78 deg C) for water cooled chillers based on Dick's email dated June 4, 2010 !- and 55 F (12.7 deg C) for air cooled chillers !- based on email string and energyplus support clarification dated June 1, 2010...also changed the upper limit for air cooled chillers to 125 F (51.67 deg C) !- and the water cooled chillers to 115 F (46.11 deg C) later the same day... ! Temporary changes to address Dick's wrong PLR curves. On Oct. 27, 2010 ! Water cooled chiller PLR curve comes from E+ data library "ReformEIRChiller Carrier 19FA 5651kW/5.50COP/Vanes EIRFPLR" ! Air-cooled chiller PLR comes from the original curve before addendum M. !- Water cooled chillers: Positive Displacement chillers... !- 90.1-2004 and 2007 Baseline curves... Curve:Biquadratic, WC_PD_2004_CAPFT, !- Name 0.9061150, !- Coefficient1 Constant 0.0292277, !- Coefficient2 x -0.0003647, !- Coefficient3 x**2 -0.0009709, !- Coefficient4 y -0.0000905, !- Coefficient5 y**2 0.0002527, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_PD_2004_EIRFT, !- Name 0.3617105, !- Coefficient1 Constant -0.0229833, !- Coefficient2 x 0.0009519, !- Coefficient3 x**2 0.0131889, !- Coefficient4 y 0.0003752, !- Coefficient5 y**2 -0.0007059, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Bicubic, WC_PD_LT75_2004_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_75TO150_2004_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_150TO300_2004_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_GT300_2004_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- 90.1-2010 Path A curves... Curve:Biquadratic, WC_PD_LT150_2010_PA_CAPFT, !- Name 0.9061150, !- Coefficient1 Constant 0.0292277, !- Coefficient2 x -0.0003647, !- Coefficient3 x**2 -0.0009709, !- Coefficient4 y -0.0000905, !- Coefficient5 y**2 0.0002527, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_PD_LT150_2010_PA_EIRFT, !- Name 0.3617105, !- Coefficient1 Constant -0.0229833, !- Coefficient2 x 0.0009519, !- Coefficient3 x**2 0.0131889, !- Coefficient4 y 0.0003752, !- Coefficient5 y**2 -0.0007059, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_PD_GT150_2010_PA_CAPFT, !- Name 0.9061150, !- Coefficient1 Constant 0.0292277, !- Coefficient2 x -0.0003647, !- Coefficient3 x**2 -0.0009709, !- Coefficient4 y -0.0000905, !- Coefficient5 y**2 0.0002527, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_PD_GT150_2010_PA_EIRFT, !- Name 0.3773115, !- Coefficient1 Constant -0.0229032, !- Coefficient2 x 0.0016504, !- Coefficient3 x**2 0.0118156, !- Coefficient4 y 0.0004345, !- Coefficient5 y**2 -0.0010132, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Bicubic, WC_PD_LT75_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_75TO150_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_150TO300_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_GT300_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- 90.1-2010 Path B curves.. Curve:Biquadratic, WC_PD_2010_PB_CAPFT, !- Name 0.9061171, !- Coefficient1 Constant 0.0292267, !- Coefficient2 x -0.0003665, !- Coefficient3 x**2 -0.0009698, !- Coefficient4 y -0.0000907, !- Coefficient5 y**2 0.0002535, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_PD_2010_PB_EIRFT, !- Name 0.3617782, !- Coefficient1 Constant -0.0230016, !- Coefficient2 x 0.0009672, !- Coefficient3 x**2 0.0131801, !- Coefficient4 y 0.0003761, !- Coefficient5 y**2 -0.0007121, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Bicubic, WC_PD_LT75_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_75TO150_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_150TO300_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_PD_GT300_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- Water cooled chillers: Centrifugal Chillers... !- 90.1-2004 Baseline curves... Curve:Biquadratic, WC_Cent_LT150_2004_CAPFT, !- Name 0.7446451, !- Coefficient1 Constant 0.0114858, !- Coefficient2 x 0.0000148, !- Coefficient3 x**2 0.0224010, !- Coefficient4 y -0.0006880, !- Coefficient5 y**2 0.0009839, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_Cent_LT150_2004_EIRFT, !- Name 0.7728770, !- Coefficient1 Constant 0.0221010, !- Coefficient2 x -0.0000799, !- Coefficient3 x**2 -0.0070045, !- Coefficient4 y 0.0004763, !- Coefficient5 y**2 -0.0010612, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_Cent_GT150_2004_CAPFT, !- Name 0.7600172, !- Coefficient1 Constant 0.0147432, !- Coefficient2 x 0.0002144, !- Coefficient3 x**2 0.0207218, !- Coefficient4 y -0.0006425, !- Coefficient5 y**2 0.0008007, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_Cent_GT150_2004_EIRFT, !- Name 0.6772577, !- Coefficient1 Constant 0.0117857, !- Coefficient2 x -0.0001967, !- Coefficient3 x**2 0.0014414, !- Coefficient4 y 0.0003005, !- Coefficient5 y**2 -0.0006807, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Bicubic, WC_Cent_LT150_2004_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_150TO300_2004_EIRFPLR,!- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_GT300_2004_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- 90.1-2010 Path A curves... Curve:Biquadratic, WC_Cent_2010_PA_CAPFT, !- Name 0.7600172, !- Coefficient1 Constant 0.0147432, !- Coefficient2 x 0.0002144, !- Coefficient3 x**2 0.0207218, !- Coefficient4 y -0.0006425, !- Coefficient5 y**2 0.0008007, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_Cent_2010_PA_EIRFT, !- Name 0.6772577, !- Coefficient1 Constant 0.0117857, !- Coefficient2 x -0.0001967, !- Coefficient3 x**2 0.0014414, !- Coefficient4 y 0.0003005, !- Coefficient5 y**2 -0.0006807, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Bicubic, WC_Cent_LT150_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_150TO300_2010_PA_EIRFPLR,!- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_300TO600_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_GT600_2010_PA_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- 90.1-2010 Path B curves... Curve:Biquadratic, WC_Cent_2010_PB_CAPFT, !- Name 0.5362340, !- Coefficient1 Constant 0.005581, !- Coefficient2 x -0.0013654, !- Coefficient3 x**2 0.0488966, !- Coefficient4 y -0.0012018, !- Coefficient5 y**2 0.0010523, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Biquadratic, WC_Cent_2010_PB_EIRFT, !- Name 1.0821822, !- Coefficient1 Constant 0.0042977, !- Coefficient2 x -0.0013182, !- Coefficient3 x**2 -0.0260781, !- Coefficient4 y 0.0008256, !- Coefficient5 y**2 -0.0006013, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 17.78, !- Minimum Value of y 46.11; !- Maximum Value of y Curve:Bicubic, WC_Cent_LT150_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_150TO300_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_300TO600_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y Curve:Bicubic, WC_Cent_GT600_2010_PB_EIRFPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- Air cooled chillers... !- 90.1-2004 Baseline curves... Curve:Biquadratic, AC_2004_CAPFT, !- Name 1.0433811, !- Coefficient1 Constant 0.0407077, !- Coefficient2 x 0.0004506, !- Coefficient3 x**2 -0.0041514, !- Coefficient4 y -0.0000886, !- Coefficient5 y**2 -0.0003467, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 12.7, !- Minimum Value of y 51.67; !- Maximum Value of y Curve:Biquadratic, AC_2004_EIRFT, !- Name 0.5961915, !- Coefficient1 Constant -0.0099496, !- Coefficient2 x 0.0007888, !- Coefficient3 x**2 0.0004506, !- Coefficient4 y 0.0004875, !- Coefficient5 y**2 -0.0007623, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 12.7, !- Minimum Value of y 51.67; !- Maximum Value of y Curve:Quadratic, AC_LT150_2004_EIRFPLR, !- Name 0.1410, !- Coefficient1 Constant 0.6550, !- Coefficient2 x 0.2030, !- Coefficient3 x**2 0.0000, !- Minimum Value of x 1.0000; !- Maximum Value of x Curve:Quadratic, AC_GT150_2004_EIRFPLR, !- Name 0.1410, !- Coefficient1 Constant 0.6550, !- Coefficient2 x 0.2030, !- Coefficient3 x**2 0.0000, !- Minimum Value of x 1.0000; !- Maximum Value of x !- 90.1-2010 Path A curves... Curve:Biquadratic, AC_2010_PA_CAPFT, !- Name 1.0433825, !- Coefficient1 Constant 0.0407073, !- Coefficient2 x 0.0004506, !- Coefficient3 x**2 -0.0041514, !- Coefficient4 y -0.0000886, !- Coefficient5 y**2 -0.0003467, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 12.7, !- Minimum Value of y 51.67; !- Maximum Value of y Curve:Biquadratic, AC_2010_PA_EIRFT, !- Name 0.5961907, !- Coefficient1 Constant -0.0099493, !- Coefficient2 x 0.0007888, !- Coefficient3 x**2 0.0004506, !- Coefficient4 y 0.0004875, !- Coefficient5 y**2 -0.0007623, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 12.7, !- Minimum Value of y 51.67; !- Maximum Value of y Curve:Quadratic, AC_LT150_2010_PA_EIRFPLR, !- Name 0.1410, !- Coefficient1 Constant 0.6550, !- Coefficient2 x 0.2030, !- Coefficient3 x**2 0.0000, !- Minimum Value of x 1.0000; !- Maximum Value of x Curve:Quadratic, AC_GT150_2010_PA_EIRFPLR, !- Name 0.1410, !- Coefficient1 Constant 0.6550, !- Coefficient2 x 0.2030, !- Coefficient3 x**2 0.0000, !- Minimum Value of x 1.0000; !- Maximum Value of x !- =========== ALL OBJECTS IN CLASS: CURVE:BIQUADRATIC =========== !***** Following curve is from Dick Lord's Chiller Model study for ASHRAE 2007 baseline ***** Curve:Biquadratic, ChillerCentCapFT, !- Name 0.7446451, !- Coefficient1 Constant 0.0114858, !- Coefficient2 x 0.0000148, !- Coefficient3 x**2 0.0224010, !- Coefficient4 y -0.0006880, !- Coefficient5 y**2 0.0009839, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 24.0000, !- Minimum Value of y 35.0000; !- Maximum Value of y !***** Following curve is from Dick Lord's Chiller Model study for ASHRAE 2007 baseline ***** Curve:Biquadratic, ChillerCentEIRFT, !- Name 0.7728770, !- Coefficient1 Constant 0.0221010, !- Coefficient2 x -0.0000799, !- Coefficient3 x**2 -0.0070045, !- Coefficient4 y 0.0004763, !- Coefficient5 y**2 -0.0010612, !- Coefficient6 x*y 5.0000, !- Minimum Value of x 10.0000, !- Maximum Value of x 24.0000, !- Minimum Value of y 35.0000; !- Maximum Value of y !- =========== ALL OBJECTS IN CLASS: CURVE:BICUBIC =========== !***** Following curve is from Dick Lord's Chiller Model study for ASHRAE 2007 baseline ***** Curve:Bicubic, ChillerCentEIRPLR, !- Name -1.360532E-01, !- Coefficient1 Constant 8.642703E-03, !- Coefficient2 x 3.855583E-06, !- Coefficient3 x**2 1.024034E+00, !- Coefficient4 y 6.047444E-02, !- Coefficient5 y**2 -8.947860E-03, !- Coefficient6 x*y 0.000000E+00, !- Coefficient7 x**3 5.706602E-02, !- Coefficient8 y**3 0.000000E+00, !- Coefficient9 x**2*y 0.000000E+00, !- Coefficient10 x*y**2 31.13, !- Minimum Value of x 36.52, !- Maximum Value of x 0.19, !- Minimum Value of y 1.03; !- Maximum Value of y !- =========== ALL OBJECTS IN CLASS: NODE LIST =========== NodeList, Basement Inlet Nodes, !- Name Basement Direct Air Inlet Node Name; !- Node 1 Name NodeList, Core_bottom Inlet Nodes, !- Name Core_bottom VAV Box Outlet Node; !- Node 1 Name NodeList, Core_mid Inlet Nodes, !- Name Core_mid VAV Box Outlet Node; !- Node 1 Name NodeList, Core_top Inlet Nodes, !- Name Core_top VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_bot_ZN_3 Inlet Nodes, !- Name Perimeter_bot_ZN_3 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_bot_ZN_2 Inlet Nodes, !- Name Perimeter_bot_ZN_2 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_bot_ZN_1 Inlet Nodes, !- Name Perimeter_bot_ZN_1 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_bot_ZN_4 Inlet Nodes, !- Name Perimeter_bot_ZN_4 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_mid_ZN_3 Inlet Nodes, !- Name Perimeter_mid_ZN_3 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_mid_ZN_2 Inlet Nodes, !- Name Perimeter_mid_ZN_2 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_mid_ZN_1 Inlet Nodes, !- Name Perimeter_mid_ZN_1 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_mid_ZN_4 Inlet Nodes, !- Name Perimeter_mid_ZN_4 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_top_ZN_3 Inlet Nodes, !- Name Perimeter_top_ZN_3 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_top_ZN_2 Inlet Nodes, !- Name Perimeter_top_ZN_2 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_top_ZN_1 Inlet Nodes, !- Name Perimeter_top_ZN_1 VAV Box Outlet Node; !- Node 1 Name NodeList, Perimeter_top_ZN_4 Inlet Nodes, !- Name Perimeter_top_ZN_4 VAV Box Outlet Node; !- Node 1 Name NodeList, CAV_bas_OANode List, !- Name CAV_bas_OAInlet Node; !- Node 1 Name NodeList, VAV_bot WITH REHEAT_OANode List, !- Name VAV_bot WITH REHEAT_OAInlet Node; !- Node 1 Name NodeList, VAV_mid WITH REHEAT_OANode List, !- Name VAV_mid WITH REHEAT_OAInlet Node; !- Node 1 Name NodeList, VAV_top WITH REHEAT_OANode List, !- Name VAV_top WITH REHEAT_OAInlet Node; !- Node 1 Name NodeList, DataCenter Basement Inlets, !- Name DataCenter Basement Supply Inlet; !- Node 1 Name NodeList, DataCenter bot Inlets, !- Name DataCenter bot Supply Inlet; !- Node 1 Name NodeList, DataCenter mid Inlets, !- Name DataCenter mid Supply Inlet; !- Node 1 Name NodeList, DataCenter top Inlets, !- Name DataCenter top Supply Inlet; !- Node 1 Name !- =========== ALL OBJECTS IN CLASS: BRANCH LIST =========== BranchList, CAV_bas Air Loop Branches, !- Name CAV_bas Air Loop Main Branch; !- Branch 1 Name BranchList, VAV_bot WITH REHEAT Air Loop Branches, !- Name VAV_bot WITH REHEAT Air Loop Main Branch; !- Branch 1 Name BranchList, VAV_mid WITH REHEAT Air Loop Branches, !- Name VAV_mid WITH REHEAT Air Loop Main Branch; !- Branch 1 Name BranchList, VAV_top WITH REHEAT Air Loop Branches, !- Name VAV_top WITH REHEAT Air Loop Main Branch; !- Branch 1 Name BranchList, SHWSys1 Supply Branches, !- Name SHWSys1 Supply Inlet Branch, !- Branch 1 Name SHWSys1 Supply Equipment Branch, !- Branch 2 Name SHWSys1 Supply Equipment Bypass Branch, !- Branch 3 Name SHWSys1 Supply Outlet Branch; !- Branch 4 Name BranchList, SHWSys1 Demand Branches, !- Name SHWSys1 Demand Inlet Branch, !- Branch 1 Name SHWSys1 Demand Load Branch 1, !- Branch 2 Name SHWSys1 Demand Load Branch 2, !- Branch 3 Name SHWSys1 Demand Load Branch 3, !- Branch 4 Name SHWSys1 Demand Bypass Branch, !- Branch 5 Name SHWSys1 Demand Outlet Branch; !- Branch 6 Name BranchList, HeatSys1 Supply Branches,!- Name HeatSys1 Supply Inlet Branch, !- Branch 1 Name HeatSys1 Supply Equipment Branch, !- Branch 2 Name HeatSys1 Supply Equipment Bypass Branch, !- Branch 3 Name HeatSys1 Supply Outlet Branch; !- Branch 4 Name BranchList, HeatSys1 Demand Branches,!- Name HeatSys1 Demand Inlet Branch, !- Branch 1 Name HeatSys1 Demand Load Branch 1, !- Branch 2 Name HeatSys1 Demand Load Branch 2, !- Branch 3 Name HeatSys1 Demand Load Branch 3, !- Branch 4 Name HeatSys1 Demand Load Branch 4, !- Branch 5 Name HeatSys1 Demand Load Branch 5, !- Branch 6 Name HeatSys1 Demand Load Branch 6, !- Branch 7 Name HeatSys1 Demand Load Branch 7, !- Branch 8 Name HeatSys1 Demand Load Branch 8, !- Branch 9 Name HeatSys1 Demand Load Branch 9, !- Branch 10 Name HeatSys1 Demand Load Branch 10, !- Branch 11 Name HeatSys1 Demand Load Branch 11, !- Branch 12 Name HeatSys1 Demand Load Branch 12, !- Branch 13 Name HeatSys1 Demand Load Branch 13, !- Branch 14 Name HeatSys1 Demand Load Branch 14, !- Branch 15 Name HeatSys1 Demand Load Branch 15, !- Branch 16 Name HeatSys1 Demand Load Branch 17, !- Branch 17 Name HeatSys1 Demand Load Branch 18, !- Branch 18 Name HeatSys1 Demand Load Branch 19, !- Branch 19 Name HeatSys1 Demand Load Branch 20, !- Branch 20 Name HeatSys1 Demand Load Branch 21, !- Branch 21 Name HeatSys1 Demand Bypass Branch, !- Branch 22 Name HeatSys1 Demand Outlet Branch; !- Branch 23 Name BranchList, CoolSys1 Supply Supply Side Branches,!- Name CoolSys1 Supply Inlet Branch, !- Branch 1 Name CoolSys1 Supply Equipment Branch 1, !- Branch 2 Name CoolSys1 Supply Equipment Branch 2, !- Branch 3 Name CoolSys1 Supply Equipment Bypass Branch, !- Branch 4 Name CoolSys1 Supply Outlet Branch; !- Branch 5 Name BranchList, CoolSys1 Demand Demand Side Branches,!- Name CoolSys1 Demand Inlet Branch, !- Branch 1 Name CoolSys1 Demand Load Branch 1, !- Branch 2 Name CoolSys1 Demand Load Branch 2, !- Branch 3 Name CoolSys1 Demand Load Branch 3, !- Branch 4 Name CoolSys1 Demand Load Branch 4, !- Branch 5 Name CoolSys1 Demand Outlet Branch; !- Branch 6 Name BranchList, TowerWaterSys Supply Branches, !- Name TowerWaterSys Supply Inlet Branch, !- Branch 1 Name TowerWaterSys Supply Equipment Branch 1, !- Branch 2 Name TowerWaterSys Supply Equipment Branch 2, !- Branch 3 Name TowerWaterSys Supply Equipment Bypass Branch, !- Branch 4 Name TowerWaterSys Supply Outlet Branch; !- Branch 5 Name BranchList, TowerWaterSys Demand Branches, !- Name TowerWaterSys Demand Inlet Branch, !- Branch 1 Name TowerWaterSys Demand Load Branch 1, !- Branch 2 Name TowerWaterSys Demand Load Branch 2, !- Branch 3 Name TowerWaterSys Demand Bypass Branch, !- Branch 4 Name TowerWaterSys Demand Outlet Branch; !- Branch 5 Name BranchList, AirLoop DataCenter Basement Branches, !- Name AirLoop DataCenter Basement Main Branch; !- Branch 1 Name BranchList, AirLoop DataCenter bot Branches, !- Name AirLoop DataCenter bot Main Branch; !- Branch 1 Name BranchList, AirLoop DataCenter mid Branches, !- Name AirLoop DataCenter mid Main Branch; !- Branch 1 Name BranchList, AirLoop DataCenter top Branches, !- Name AirLoop DataCenter top Main Branch; !- Branch 1 Name BranchList, Plant Supply Side Branches, !- Name Plant Supply Inlet Branch, !- Branch 1 Name Plant Supply Tower Branch, !- Branch 2 Name Dummy Boiler Branch, !- Branch 3 Name Plant Supply Bypass Branch, !- Branch 4 Name Plant Supply Outlet Branch; !- Branch 5 Name BranchList, Plant Demand Side Branches, !- Name Plant Demand Inlet Branch, !- Branch 1 Name WLHP Cooling Plant Branch AirLoop DataCenter Basement, !- Branch 2 Name WLHP Heating Plant Branch AirLoop DataCenter Basement, !- Branch 3 Name WLHP Cooling Plant Branch AirLoop DataCenter bot, !- Branch 4 Name WLHP Heating Plant Branch AirLoop DataCenter bot, !- Branch 5 Name WLHP Cooling Plant Branch AirLoop DataCenter mid, !- Branch 6 Name WLHP Heating Plant Branch AirLoop DataCenter mid, !- Branch 7 Name WLHP Cooling Plant Branch AirLoop DataCenter top, !- Branch 8 Name WLHP Heating Plant Branch AirLoop DataCenter top, !- Branch 9 Name Plant Demand Bypass Branch, !- Branch 10 Name Plant Demand Outlet Branch; !- Branch 11 Name BranchList, CoolSys1 Supply Demand Side Branches, !- Name CoolSys1 Supply Demand Side Inlet Branch, !- Branch 1 Name CoolSys1 Heat Exchanger Supply Branch, !- Branch 2 Name CoolSys1 Supply Side Bypass, !- Branch 3 Name CoolSys1 Supply Demand Side Outlet Branch; !- Branch 4 Name BranchList, CoolSys1 Demand Supply Side Branches, !- Name CoolSys1 Demand Supply Side Inlet Branch, !- Branch 1 Name CoolSys1 Heat Exchanger Demand Branch, !- Branch 2 Name CoolSys1 Demand Side Bypass, !- Branch 3 Name CoolSys1 Demand Supply Side Outlet Branch; !- Branch 4 Name !- =========== ALL OBJECTS IN CLASS: CONNECTOR LIST =========== ConnectorList, SHWSys1 Supply Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type SHWSys1 Supply Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type SHWSys1 Supply Mixer; !- Connector 2 Name ConnectorList, SHWSys1 Demand Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type SHWSys1 Demand Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type SHWSys1 Demand Mixer; !- Connector 2 Name ConnectorList, HeatSys1 Supply Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type HeatSys1 Supply Splitter,!- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type HeatSys1 Supply Mixer; !- Connector 2 Name ConnectorList, HeatSys1 Demand Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type HeatSys1 Demand Splitter,!- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type HeatSys1 Demand Mixer; !- Connector 2 Name ConnectorList, CoolSys1 Supply Supply Side Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type CoolSys1 Supply Supply Side Splitter,!- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type CoolSys1 Supply Supply Side Mixer; !- Connector 2 Name ConnectorList, CoolSys1 Demand Demand Side Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type CoolSys1 Demand Demand Side Splitter,!- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type CoolSys1 Demand Demand Side Mixer; !- Connector 2 Name ConnectorList, TowerWaterSys Supply Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type TowerWaterSys Supply Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type TowerWaterSys Supply Mixer; !- Connector 2 Name ConnectorList, TowerWaterSys Demand Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type TowerWaterSys Demand Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type TowerWaterSys Demand Mixer; !- Connector 2 Name ConnectorList, CoolSys1 Supply Demand Side Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type CoolSys1 Supply Demand Side Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type CoolSys1 Supply Demand Side Mixer; !- Connector 2 Name ConnectorList, CoolSys1 Demand Supply Side Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type CoolSys1 Demand Supply Side Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type CoolSys1 Demand Supply Side Mixer; !- Connector 2 Name ConnectorList, Plant Supply Side Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type Plant Supply Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type Plant Supply Mixer; !- Connector 2 Name ConnectorList, Plant Demand Side Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type Plant Demand Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type Plant Demand Mixer; !- Connector 2 Name !- =========== ALL OBJECTS IN CLASS: BRANCH =========== Branch, CAV_bas Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type CAV_bas_OA, !- Component 1 Name CAV_bas Supply Equipment Inlet Node, !- Component 1 Inlet Node Name CAV_bas_OA-CAV_CoolCNode,!- Component 1 Outlet Node Name Coil:Cooling:Water, !- Component 2 Object Type CAV_bas_CoolC, !- Component 2 Name CAV_bas_OA-CAV_CoolCNode,!- Component 2 Inlet Node Name CAV_bas_CoolC-CAV_HeatCNode, !- Component 2 Outlet Node Name Coil:Heating:Water, !- Component 3 Object Type CAV_bas_HeatC, !- Component 3 Name CAV_bas_CoolC-CAV_HeatCNode, !- Component 3 Inlet Node Name CAV_bas_HeatC-CAV_FanNode, !- Component 3 Outlet Node Name Fan:ConstantVolume, !- Component 4 Object Type CAV_bas Fan, !- Component 4 Name CAV_bas_HeatC-CAV_FanNode, !- Component 4 Inlet Node Name CAV_bas Supply Equipment Outlet Node; !- Component 4 Outlet Node Name Branch, VAV_bot WITH REHEAT Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type VAV_bot WITH REHEAT_OA, !- Component 1 Name VAV_bot WITH REHEAT Supply Equipment Inlet Node, !- Component 1 Inlet Node Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Component 1 Outlet Node Name Coil:Cooling:Water, !- Component 2 Object Type VAV_bot WITH REHEAT_CoolC, !- Component 2 Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Component 2 Inlet Node Name VAV_bot WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Component 2 Outlet Node Name Coil:Heating:Water, !- Component 3 Object Type VAV_bot WITH REHEAT_HeatC, !- Component 3 Name VAV_bot WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Component 3 Inlet Node Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Component 3 Outlet Node Name Fan:VariableVolume, !- Component 4 Object Type VAV_bot WITH REHEAT Fan, !- Component 4 Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Component 4 Inlet Node Name VAV_bot WITH REHEAT Supply Equipment Outlet Node; !- Component 4 Outlet Node Name Branch, VAV_mid WITH REHEAT Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type VAV_mid WITH REHEAT_OA, !- Component 1 Name VAV_mid WITH REHEAT Supply Equipment Inlet Node, !- Component 1 Inlet Node Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Component 1 Outlet Node Name Coil:Cooling:Water, !- Component 2 Object Type VAV_mid WITH REHEAT_CoolC, !- Component 2 Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Component 2 Inlet Node Name VAV_mid WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Component 2 Outlet Node Name Coil:Heating:Water, !- Component 3 Object Type VAV_mid WITH REHEAT_HeatC, !- Component 3 Name VAV_mid WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Component 3 Inlet Node Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Component 3 Outlet Node Name Fan:VariableVolume, !- Component 4 Object Type VAV_mid WITH REHEAT Fan, !- Component 4 Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Component 4 Inlet Node Name VAV_mid WITH REHEAT Supply Equipment Outlet Node; !- Component 4 Outlet Node Name Branch, VAV_top WITH REHEAT Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type VAV_top WITH REHEAT_OA, !- Component 1 Name VAV_top WITH REHEAT Supply Equipment Inlet Node, !- Component 1 Inlet Node Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Component 1 Outlet Node Name Coil:Cooling:Water, !- Component 2 Object Type VAV_top WITH REHEAT_CoolC, !- Component 2 Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Component 2 Inlet Node Name VAV_top WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Component 2 Outlet Node Name Coil:Heating:Water, !- Component 3 Object Type VAV_top WITH REHEAT_HeatC, !- Component 3 Name VAV_top WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Component 3 Inlet Node Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Component 3 Outlet Node Name Fan:VariableVolume, !- Component 4 Object Type VAV_top WITH REHEAT Fan, !- Component 4 Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Component 4 Inlet Node Name VAV_top WITH REHEAT Supply Equipment Outlet Node; !- Component 4 Outlet Node Name Branch, SHWSys1 Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:ConstantSpeed, !- Component 1 Object Type SHWSys1 Pump, !- Component 1 Name SHWSys1 Supply Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Pump-SHWSys1 Water HeaterNodeviaConnector; !- Component 1 Outlet Node Name Branch, SHWSys1 Supply Equipment Branch, !- Name , !- Pressure Drop Curve Name WaterHeater:Mixed, !- Component 1 Object Type SHWSys1 Water Heater, !- Component 1 Name SHWSys1 Pump-SHWSys1 Water HeaterNode, !- Component 1 Inlet Node Name SHWSys1 Supply Equipment Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Supply Equipment Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Supply Equipment Bypass Pipe, !- Component 1 Name SHWSys1 Supply Equip Bypass Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Supply Equip Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Supply Outlet Pipe, !- Component 1 Name SHWSys1 Supply Mixer-SHWSys1 Supply Outlet Pipe, !- Component 1 Inlet Node Name SHWSys1 Supply Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Demand Inlet Pipe, !- Component 1 Name SHWSys1 Demand Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Demand Inlet Pipe-SHWSys1 Demand Mixer; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Load Branch 1, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type Core_bottom sub cat, !- Component 1 Name Core_bottom sub cat Water Inlet Node, !- Component 1 Inlet Node Name Core_bottom sub cat Water Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Load Branch 2, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type Core_mid sub cat, !- Component 1 Name Core_mid sub cat Water Inlet Node, !- Component 1 Inlet Node Name Core_mid sub cat Water Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Load Branch 3, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type Core_top sub cat, !- Component 1 Name Core_top sub cat Water Inlet Node, !- Component 1 Inlet Node Name Core_top sub cat Water Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Demand Bypass Pipe, !- Component 1 Name SHWSys1 Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Demand Bypass Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Demand Outlet Pipe, !- Component 1 Name SHWSys1 Demand Mixer-SHWSys1 Demand Outlet Pipe, !- Component 1 Inlet Node Name SHWSys1 Demand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:VariableSpeed, !- Component 1 Object Type HeatSys1 Pump, !- Component 1 Name HeatSys1 Supply Inlet Node, !- Component 1 Inlet Node Name HeatSys1 Pump-HeatSys1 BoilerNodeviaConnector; !- Component 1 Outlet Node Name Branch, HeatSys1 Supply Equipment Branch, !- Name , !- Pressure Drop Curve Name Boiler:HotWater, !- Component 1 Object Type HeatSys1 Boiler, !- Component 1 Name HeatSys1 Pump-HeatSys1 BoilerNode, !- Component 1 Inlet Node Name HeatSys1 Supply Equipment Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Supply Equipment Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type HeatSys1 Supply Equipment Bypass Pipe, !- Component 1 Name HeatSys1 Supply Equip Bypass Inlet Node, !- Component 1 Inlet Node Name HeatSys1 Supply Equip Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type HeatSys1 Supply Outlet Pipe, !- Component 1 Name HeatSys1 Supply Mixer-HeatSys1 Supply Outlet Pipe, !- Component 1 Inlet Node Name HeatSys1 Supply Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type HeatSys1 Demand Inlet Pipe, !- Component 1 Name HeatSys1 Demand Inlet Node, !- Component 1 Inlet Node Name HeatSys1 Demand Inlet Pipe-HeatSys1 Demand Mixer; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 1, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Core_bottom VAV Box Reheat Coil, !- Component 1 Name Core_bottom VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Core_bottom VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 2, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Core_mid VAV Box Reheat Coil, !- Component 1 Name Core_mid VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Core_mid VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 3, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Core_top VAV Box Reheat Coil, !- Component 1 Name Core_top VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Core_top VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 4, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_bot_ZN_3 VAV Box Reheat Coil, !- Component 1 Name Perimeter_bot_ZN_3 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_bot_ZN_3 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 5, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_bot_ZN_2 VAV Box Reheat Coil, !- Component 1 Name Perimeter_bot_ZN_2 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_bot_ZN_2 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 6, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_bot_ZN_1 VAV Box Reheat Coil, !- Component 1 Name Perimeter_bot_ZN_1 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_bot_ZN_1 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 7, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_bot_ZN_4 VAV Box Reheat Coil, !- Component 1 Name Perimeter_bot_ZN_4 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_bot_ZN_4 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 8, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_mid_ZN_3 VAV Box Reheat Coil, !- Component 1 Name Perimeter_mid_ZN_3 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_mid_ZN_3 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 9, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_mid_ZN_2 VAV Box Reheat Coil, !- Component 1 Name Perimeter_mid_ZN_2 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_mid_ZN_2 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 10, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_mid_ZN_1 VAV Box Reheat Coil, !- Component 1 Name Perimeter_mid_ZN_1 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_mid_ZN_1 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 11, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_mid_ZN_4 VAV Box Reheat Coil, !- Component 1 Name Perimeter_mid_ZN_4 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_mid_ZN_4 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 12, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_top_ZN_3 VAV Box Reheat Coil, !- Component 1 Name Perimeter_top_ZN_3 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_top_ZN_3 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 13, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_top_ZN_2 VAV Box Reheat Coil, !- Component 1 Name Perimeter_top_ZN_2 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_top_ZN_2 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 14, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_top_ZN_1 VAV Box Reheat Coil, !- Component 1 Name Perimeter_top_ZN_1 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_top_ZN_1 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 15, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type Perimeter_top_ZN_4 VAV Box Reheat Coil, !- Component 1 Name Perimeter_top_ZN_4 VAV Box Reheat CoilDemand Inlet Node, !- Component 1 Inlet Node Name Perimeter_top_ZN_4 VAV Box Reheat CoilDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 17, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type VAV_bot WITH REHEAT_HeatC, !- Component 1 Name VAV_bot WITH REHEAT_HeatCDemand Inlet Node, !- Component 1 Inlet Node Name VAV_bot WITH REHEAT_HeatCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 18, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type VAV_mid WITH REHEAT_HeatC, !- Component 1 Name VAV_mid WITH REHEAT_HeatCDemand Inlet Node, !- Component 1 Inlet Node Name VAV_mid WITH REHEAT_HeatCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 19, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type VAV_top WITH REHEAT_HeatC, !- Component 1 Name VAV_top WITH REHEAT_HeatCDemand Inlet Node, !- Component 1 Inlet Node Name VAV_top WITH REHEAT_HeatCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 20, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type CAV_bas_HeatC, !- Component 1 Name CAV_bas_HeatCDemand Inlet Node, !- Component 1 Inlet Node Name CAV_bas_HeatCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Load Branch 21, !- Name , !- Pressure Drop Curve Name Coil:Heating:Water, !- Component 1 Object Type DataCenter_ExtraWaterHeatC, !- Component 1 Name DataCenter_ExtraWaterHeatCDemand Inlet Node, !- Component 1 Inlet Node Name DataCenter_ExtraWaterHeatCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type HeatSys1 Demand Bypass Pipe, !- Component 1 Name HeatSys1 Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name HeatSys1 Demand Bypass Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, HeatSys1 Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type HeatSys1 Demand Outlet Pipe, !- Component 1 Name HeatSys1 Demand Mixer-HeatSys1 Demand Outlet Pipe, !- Component 1 Inlet Node Name HeatSys1 Demand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Supply Inlet Pipe, !- Component 1 Name CoolSys1 Supply Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Pump-CoolSys1 ChillerNodeviaConnector; !- Component 1 Outlet Node Name Branch, CoolSys1 Supply Equipment Branch 1, !- Name , !- Pressure Drop Curve Name Pump:ConstantSpeed, !- Component 1 Object Type CoolSys1 Chiller1 Pump, !- Component 1 Name CoolSys1 Chiller1 Pump Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Pump-CoolSys1 Chiller1Node, !- Component 1 Outlet Node Name Chiller:Electric:ReformulatedEIR, !- Component 2 Object Type CoolSys1 Chiller1, !- Component 2 Name CoolSys1 Pump-CoolSys1 Chiller1Node, !- Component 2 Inlet Node Name CoolSys1 Supply Equipment Outlet Node 1; !- Component 2 Outlet Node Name Branch, CoolSys1 Supply Equipment Branch 2, !- Name , !- Pressure Drop Curve Name Pump:ConstantSpeed, !- Component 1 Object Type CoolSys1 Chiller2 Pump, !- Component 1 Name CoolSys1 Chiller2 Pump Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Pump-CoolSys1 Chiller2Node, !- Component 1 Outlet Node Name Chiller:Electric:ReformulatedEIR, !- Component 2 Object Type CoolSys1 Chiller2, !- Component 2 Name CoolSys1 Pump-CoolSys1 Chiller2Node, !- Component 2 Inlet Node Name CoolSys1 Supply Equipment Outlet Node 2; !- Component 2 Outlet Node Name Branch, CoolSys1 Supply Equipment Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Supply Equipment Bypass Pipe, !- Component 1 Name CoolSys1 Supply Equip Bypass Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Supply Equip Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Supply Outlet Pipe, !- Component 1 Name CoolSys1 Supply Mixer-CoolSys1 Supply Outlet Pipe, !- Component 1 Inlet Node Name CoolSys1 Supply Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:VariableSpeed, !- Component 1 Object Type CoolSys1 Pump Secondary, !- Component 1 Name CoolSys1 Demand Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Pump Secondary-CoolSys1 Demand Mixer; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Load Branch 1, !- Name , !- Pressure Drop Curve Name Coil:Cooling:Water, !- Component 1 Object Type VAV_bot WITH REHEAT_CoolC, !- Component 1 Name VAV_bot WITH REHEAT_CoolCDemand Inlet Node, !- Component 1 Inlet Node Name VAV_bot WITH REHEAT_CoolCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Load Branch 2, !- Name , !- Pressure Drop Curve Name Coil:Cooling:Water, !- Component 1 Object Type VAV_mid WITH REHEAT_CoolC, !- Component 1 Name VAV_mid WITH REHEAT_CoolCDemand Inlet Node, !- Component 1 Inlet Node Name VAV_mid WITH REHEAT_CoolCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Load Branch 3, !- Name , !- Pressure Drop Curve Name Coil:Cooling:Water, !- Component 1 Object Type VAV_top WITH REHEAT_CoolC, !- Component 1 Name VAV_top WITH REHEAT_CoolCDemand Inlet Node, !- Component 1 Inlet Node Name VAV_top WITH REHEAT_CoolCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Load Branch 4, !- Name , !- Pressure Drop Curve Name Coil:Cooling:Water, !- Component 1 Object Type CAV_bas_CoolC, !- Component 1 Name CAV_bas_CoolCDemand Inlet Node, !- Component 1 Inlet Node Name CAV_bas_CoolCDemand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Demand Outlet Pipe, !- Component 1 Name CoolSys1 Demand Mixer-CoolSys1 Demand Outlet Pipe, !- Component 1 Inlet Node Name CoolSys1 Demand Outlet Node; !- Component 1 Outlet Node Name Branch, TowerWaterSys Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name HeaderedPumps:VariableSpeed, !- Component 1 Object Type TowerWaterSys Pump, !- Component 1 Name TowerWaterSys Supply Inlet Node, !- Component 1 Inlet Node Name TowerWaterSys Pump-TowerWaterSys CoolTowerNodeviaConnector; !- Component 1 Outlet Node Name Branch, TowerWaterSys Supply Equipment Branch 1, !- Name , !- Pressure Drop Curve Name CoolingTower:VariableSpeed, !- Component 1 Object Type TowerWaterSys CoolTower 1, !- Component 1 Name TowerWaterSys Pump-TowerWaterSys CoolTower1Node, !- Component 1 Inlet Node Name TowerWaterSys Supply Equipment Outlet Node 1; !- Component 1 Outlet Node Name Branch, TowerWaterSys Supply Equipment Branch 2, !- Name , !- Pressure Drop Curve Name CoolingTower:VariableSpeed, !- Component 1 Object Type TowerWaterSys CoolTower 2, !- Component 1 Name TowerWaterSys Pump-TowerWaterSys CoolTower2Node, !- Component 1 Inlet Node Name TowerWaterSys Supply Equipment Outlet Node 2; !- Component 1 Outlet Node Name Branch, TowerWaterSys Supply Equipment Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type TowerWaterSys Supply Equipment Bypass Pipe, !- Component 1 Name TowerWaterSys Supply Equip Bypass Inlet Node, !- Component 1 Inlet Node Name TowerWaterSys Supply Equip Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, TowerWaterSys Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type TowerWaterSys Supply Outlet Pipe, !- Component 1 Name TowerWaterSys Supply Mixer-TowerWaterSys Supply Outlet Pipe, !- Component 1 Inlet Node Name TowerWaterSys Supply Outlet Node; !- Component 1 Outlet Node Name Branch, TowerWaterSys Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type TowerWaterSys Demand Inlet Pipe, !- Component 1 Name TowerWaterSys Demand Inlet Node, !- Component 1 Inlet Node Name TowerWaterSys Demand Inlet Pipe-TowerWaterSys Demand Mixer; !- Component 1 Outlet Node Name Branch, TowerWaterSys Demand Load Branch 1, !- Name , !- Pressure Drop Curve Name Chiller:Electric:ReformulatedEIR, !- Component 1 Object Type CoolSys1 Chiller1, !- Component 1 Name CoolSys1 Chiller1 Water Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Chiller1 Water Outlet Node; !- Component 1 Outlet Node Name Branch, TowerWaterSys Demand Load Branch 2, !- Name , !- Pressure Drop Curve Name Chiller:Electric:ReformulatedEIR, !- Component 1 Object Type CoolSys1 Chiller2, !- Component 1 Name CoolSys1 Chiller2 Water Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Chiller2 Water Outlet Node; !- Component 1 Outlet Node Name Branch, TowerWaterSys Demand Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type TowerWaterSys Demand Bypass Pipe, !- Component 1 Name TowerWaterSys Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name TowerWaterSys Demand Bypass Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, TowerWaterSys Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type TowerWaterSys Demand Outlet Pipe, !- Component 1 Name TowerWaterSys Demand Mixer-TowerWaterSys Demand Outlet Pipe, !- Component 1 Inlet Node Name TowerWaterSys Demand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Heat Exchanger Supply Branch, !- Name , !- Pressure Drop Curve Name HeatExchanger:FluidToFluid, !- Component 1 Object Type Bypass Heat exchanger, !- Component 1 Name CoolSys1 Exchancher Supply Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Exchancher Supply Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Heat Exchanger Demand Branch, !- Name , !- Pressure Drop Curve Name HeatExchanger:FluidToFluid, !- Component 1 Object Type Bypass Heat exchanger, !- Component 1 Name CoolSys1 Exchancher Demand Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Exchancher Demand Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Supply Side Bypass, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Supply Bypass, !- Component 1 Name CoolSys1 Supply Bypass Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Supply Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Side Bypass, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Demand Bypass, !- Component 1 Name CoolSys1 Demand Bypass Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Demand Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Supply Demand Side Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Supply Demand Side Inlet Pipe, !- Component 1 Name CoolSys1 Supply Demand Side Inlet Pipe Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Supply Demand Side Inlet Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Supply Demand Side Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Supply Demand Side Outlet Pipe , !- Component 1 Name CoolSys1 Supply Demand Side Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Supply Demand Side Outlet Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Supply Side Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Demand Supply Side Inlet Pipe , !- Component 1 Name CoolSys1 Demand Supply Side Inlet Pipe Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Demand Supply Side Inlet Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, CoolSys1 Demand Supply Side Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type CoolSys1 Demand Supply Side Outlet Pipe , !- Component 1 Name CoolSys1 Demand Supply Side Outlet Pipe Inlet Node, !- Component 1 Inlet Node Name CoolSys1 Demand Supply Side Outlet Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, AirLoop DataCenter Basement Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type AirLoop DataCenter Basement OA System, !- Component 1 Name AirLoop DataCenter Basement Return Air Inlet, !- Component 1 Inlet Node Name DataCenter Basement Mixed Air Outlet, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, !- Component 2 Object Type AirLoop DataCenter Basement DXAC Heat Pump, !- Component 2 Name DataCenter Basement Mixed Air Outlet, !- Component 2 Inlet Node Name AirLoop DataCenter Basement Humidifier Inlet, !- Component 2 Outlet Node Name Humidifier:Steam:Electric, !- Component 3 Object Type DataCenter Basement Humidifier, !- Component 3 Name AirLoop DataCenter Basement Humidifier Inlet, !- Component 3 Inlet Node Name DataCenter_Humidifier-DataCenter_ExtraElecHeatCNode, !- Component 3 Outlet Node Name Coil:Heating:Electric, !- Component 4 Object Type DataCenter_ExtraElecHeatC, !- Component 4 Name DataCenter_Humidifier-DataCenter_ExtraElecHeatCNode, !- Component 4 Inlet Node Name DataCenter_ExtraElecHeatC-DataCenter_ExtraWaterHeatCNode, !- Component 4 Outlet Node Name Coil:Heating:Water, !- Component 5 Object Type DataCenter_ExtraWaterHeatC, !- Component 5 Name DataCenter_ExtraElecHeatC-DataCenter_ExtraWaterHeatCNode, !- Component 5 Inlet Node Name AirLoop DataCenter Basement Supply Air Outlet; !- Component 5 Outlet Node Name Branch, AirLoop DataCenter bot Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type AirLoop DataCenter bot OA System, !- Component 1 Name AirLoop DataCenter bot Return Air Inlet, !- Component 1 Inlet Node Name DataCenter bot Mixed Air Outlet, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, !- Component 2 Object Type AirLoop DataCenter bot DXAC Heat Pump, !- Component 2 Name DataCenter bot Mixed Air Outlet, !- Component 2 Inlet Node Name AirLoop DataCenter bot Supply Air Outlet; !- Component 2 Outlet Node Name Branch, AirLoop DataCenter mid Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type AirLoop DataCenter mid OA System, !- Component 1 Name AirLoop DataCenter mid Return Air Inlet, !- Component 1 Inlet Node Name DataCenter mid Mixed Air Outlet, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, !- Component 2 Object Type AirLoop DataCenter mid DXAC Heat Pump, !- Component 2 Name DataCenter mid Mixed Air Outlet, !- Component 2 Inlet Node Name AirLoop DataCenter mid Supply Air Outlet; !- Component 2 Outlet Node Name Branch, AirLoop DataCenter top Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type AirLoop DataCenter top OA System, !- Component 1 Name AirLoop DataCenter top Return Air Inlet, !- Component 1 Inlet Node Name DataCenter top Mixed Air Outlet, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, !- Component 2 Object Type AirLoop DataCenter top DXAC Heat Pump, !- Component 2 Name DataCenter top Mixed Air Outlet, !- Component 2 Inlet Node Name AirLoop DataCenter top Supply Air Outlet; !- Component 2 Outlet Node Name Branch, Plant Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:ConstantSpeed, !- Component 1 Object Type Plant Circ Pump, !- Component 1 Name Plant Supply Inlet Node, !- Component 1 Inlet Node Name Plant Pump Outlet Node; !- Component 1 Outlet Node Name Branch, Plant Supply Tower Branch, !- Name , !- Pressure Drop Curve Name FluidCooler:TwoSpeed, !- Component 1 Object Type Central Tower, !- Component 1 Name Central Tower Inlet Node,!- Component 1 Inlet Node Name Central Tower Outlet Node; !- Component 1 Outlet Node Name Branch, Dummy Boiler Branch, !- Name , !- Pressure Drop Curve Name Boiler:HotWater, !- Component 1 Object Type Dummy Boiler, !- Component 1 Name Dummy Boiler Inlet Node, !- Component 1 Inlet Node Name Dummy Boiler Outlet Node;!- Component 1 Outlet Node Name Branch, Plant Supply Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Plant Supply Side Bypass,!- Component 1 Name Plant Supply Bypass Inlet Node, !- Component 1 Inlet Node Name Plant Supply Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, Plant Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Plant Supply Outlet, !- Component 1 Name Plant Supply Exit Pipe Inlet Node, !- Component 1 Inlet Node Name Plant Supply Outlet Node;!- Component 1 Outlet Node Name Branch, Plant Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Plant Demand Inlet Pipe, !- Component 1 Name Plant Demand Inlet Node, !- Component 1 Inlet Node Name Plant Demand Entrance Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, Plant Demand Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Plant Demand Side Bypass,!- Component 1 Name Cond Demand Bypass Inlet Node, !- Component 1 Inlet Node Name Cond Demand Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, Plant Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type Plant Demand Outlet Pipe,!- Component 1 Name Plant Demand Exit Pipe Inlet Node, !- Component 1 Inlet Node Name Plant Demand Outlet Node;!- Component 1 Outlet Node Name Branch, WLHP Cooling Plant Branch AirLoop DataCenter Basement, !- Name , !- Pressure Drop Curve Name Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Cooling Mode AirLoop DataCenter Basement, !- Component 1 Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side1 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side1 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Heating Plant Branch AirLoop DataCenter Basement, !- Name , !- Pressure Drop Curve Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Heating Mode AirLoop DataCenter Basement, !- Component 1 Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side2 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side2 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Cooling Plant Branch AirLoop DataCenter bot, !- Name , !- Pressure Drop Curve Name Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Cooling Mode AirLoop DataCenter bot, !- Component 1 Name AirLoop DataCenter bot Water to Air Heat Pump Source Side1 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter bot Water to Air Heat Pump Source Side1 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Cooling Plant Branch AirLoop DataCenter mid, !- Name , !- Pressure Drop Curve Name Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Cooling Mode AirLoop DataCenter mid, !- Component 1 Name AirLoop DataCenter mid Water to Air Heat Pump Source Side1 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter mid Water to Air Heat Pump Source Side1 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Cooling Plant Branch AirLoop DataCenter top, !- Name , !- Pressure Drop Curve Name Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Cooling Mode AirLoop DataCenter top, !- Component 1 Name AirLoop DataCenter top Water to Air Heat Pump Source Side1 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter top Water to Air Heat Pump Source Side1 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Heating Plant Branch AirLoop DataCenter bot, !- Name , !- Pressure Drop Curve Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Heating Mode AirLoop DataCenter bot, !- Component 1 Name AirLoop DataCenter bot Water to Air Heat Pump Source Side2 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter bot Water to Air Heat Pump Source Side2 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Heating Plant Branch AirLoop DataCenter mid, !- Name , !- Pressure Drop Curve Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Heating Mode AirLoop DataCenter mid, !- Component 1 Name AirLoop DataCenter mid Water to Air Heat Pump Source Side2 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter mid Water to Air Heat Pump Source Side2 Outlet Node; !- Component 1 Outlet Node Name Branch, WLHP Heating Plant Branch AirLoop DataCenter top, !- Name , !- Pressure Drop Curve Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Component 1 Object Type Heat Pump Heating Mode AirLoop DataCenter top, !- Component 1 Name AirLoop DataCenter top Water to Air Heat Pump Source Side2 Inlet Node, !- Component 1 Inlet Node Name AirLoop DataCenter top Water to Air Heat Pump Source Side2 Outlet Node; !- Component 1 Outlet Node Name !- =========== ALL OBJECTS IN CLASS: PIPE =========== Pipe:Adiabatic, SHWSys1 Supply Equipment Bypass Pipe, !- Name SHWSys1 Supply Equip Bypass Inlet Node, !- Inlet Node Name SHWSys1 Supply Equip Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Supply Outlet Pipe, !- Name SHWSys1 Supply Mixer-SHWSys1 Supply Outlet Pipe, !- Inlet Node Name SHWSys1 Supply Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Demand Inlet Pipe, !- Name SHWSys1 Demand Inlet Node, !- Inlet Node Name SHWSys1 Demand Inlet Pipe-SHWSys1 Demand Mixer; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Demand Bypass Pipe, !- Name SHWSys1 Demand Bypass Pipe Inlet Node, !- Inlet Node Name SHWSys1 Demand Bypass Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Demand Outlet Pipe, !- Name SHWSys1 Demand Mixer-SHWSys1 Demand Outlet Pipe, !- Inlet Node Name SHWSys1 Demand Outlet Node; !- Outlet Node Name Pipe:Adiabatic, HeatSys1 Supply Equipment Bypass Pipe, !- Name HeatSys1 Supply Equip Bypass Inlet Node, !- Inlet Node Name HeatSys1 Supply Equip Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, HeatSys1 Supply Outlet Pipe, !- Name HeatSys1 Supply Mixer-HeatSys1 Supply Outlet Pipe, !- Inlet Node Name HeatSys1 Supply Outlet Node; !- Outlet Node Name Pipe:Adiabatic, HeatSys1 Demand Inlet Pipe, !- Name HeatSys1 Demand Inlet Node, !- Inlet Node Name HeatSys1 Demand Inlet Pipe-HeatSys1 Demand Mixer; !- Outlet Node Name Pipe:Adiabatic, HeatSys1 Demand Bypass Pipe, !- Name HeatSys1 Demand Bypass Pipe Inlet Node, !- Inlet Node Name HeatSys1 Demand Bypass Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, HeatSys1 Demand Outlet Pipe, !- Name HeatSys1 Demand Mixer-HeatSys1 Demand Outlet Pipe, !- Inlet Node Name HeatSys1 Demand Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Supply Inlet Pipe, !- Name CoolSys1 Supply Inlet Node, !- Inlet Node Name CoolSys1 Pump-CoolSys1 ChillerNodeviaConnector; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Supply Equipment Bypass Pipe, !- Name CoolSys1 Supply Equip Bypass Inlet Node, !- Inlet Node Name CoolSys1 Supply Equip Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Supply Outlet Pipe, !- Name CoolSys1 Supply Mixer-CoolSys1 Supply Outlet Pipe, !- Inlet Node Name CoolSys1 Supply Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Demand Outlet Pipe, !- Name CoolSys1 Demand Mixer-CoolSys1 Demand Outlet Pipe, !- Inlet Node Name CoolSys1 Demand Outlet Node; !- Outlet Node Name Pipe:Adiabatic, TowerWaterSys Supply Equipment Bypass Pipe, !- Name TowerWaterSys Supply Equip Bypass Inlet Node, !- Inlet Node Name TowerWaterSys Supply Equip Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, TowerWaterSys Supply Outlet Pipe, !- Name TowerWaterSys Supply Mixer-TowerWaterSys Supply Outlet Pipe, !- Inlet Node Name TowerWaterSys Supply Outlet Node; !- Outlet Node Name Pipe:Adiabatic, TowerWaterSys Demand Inlet Pipe, !- Name TowerWaterSys Demand Inlet Node, !- Inlet Node Name TowerWaterSys Demand Inlet Pipe-TowerWaterSys Demand Mixer; !- Outlet Node Name Pipe:Adiabatic, TowerWaterSys Demand Bypass Pipe, !- Name TowerWaterSys Demand Bypass Pipe Inlet Node, !- Inlet Node Name TowerWaterSys Demand Bypass Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, TowerWaterSys Demand Outlet Pipe, !- Name TowerWaterSys Demand Mixer-TowerWaterSys Demand Outlet Pipe, !- Inlet Node Name TowerWaterSys Demand Outlet Node; !- Outlet Node Name Pipe:Adiabatic, Plant Demand Inlet Pipe, !- Name Plant Demand Inlet Node, !- Inlet Node Name Plant Demand Entrance Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, Plant Demand Side Bypass,!- Name Cond Demand Bypass Inlet Node, !- Inlet Node Name Cond Demand Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, Plant Demand Outlet Pipe,!- Name Plant Demand Exit Pipe Inlet Node, !- Inlet Node Name Plant Demand Outlet Node;!- Outlet Node Name Pipe:Adiabatic, Plant Supply Side Bypass,!- Name Plant Supply Bypass Inlet Node, !- Inlet Node Name Plant Supply Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, Plant Supply Outlet, !- Name Plant Supply Exit Pipe Inlet Node, !- Inlet Node Name Plant Supply Outlet Node;!- Outlet Node Name Pipe:Adiabatic, CoolSys1 Supply Bypass, !- Name CoolSys1 Supply Bypass Inlet Node, !- Inlet Node Name CoolSys1 Supply Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Demand Bypass, !- Name CoolSys1 Demand Bypass Inlet Node, !- Inlet Node Name CoolSys1 Demand Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Supply Demand Side Inlet Pipe, !- Name CoolSys1 Supply Demand Side Inlet Pipe Inlet Node, !- Inlet Node Name CoolSys1 Supply Demand Side Inlet Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Supply Demand Side Outlet Pipe , !- Name CoolSys1 Supply Demand Side Outlet Pipe Inlet Node, !- Inlet Node Name CoolSys1 Supply Demand Side Outlet Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Demand Supply Side Outlet Pipe , !- Name CoolSys1 Demand Supply Side Outlet Pipe Inlet Node, !- Inlet Node Name CoolSys1 Demand Supply Side Outlet Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, CoolSys1 Demand Supply Side Inlet Pipe , !- Name CoolSys1 Demand Supply Side Inlet Pipe Inlet Node, !- Inlet Node Name CoolSys1 Demand Supply Side Inlet Pipe Outlet Node; !- Outlet Node Name !- =========== ALL OBJECTS IN CLASS: PLANT LOOP =========== PlantLoop, SHWSys1, !- Name WATER, !- Fluid Type , !- User Defined Fluid Type SHWSys1 Loop Operation Scheme List, !- Plant Equipment Operation Scheme Name SHWSys1 Supply Outlet Node, !- Loop Temperature Setpoint Node Name 60.0, !- Maximum Loop Temperature {C} 10.0, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0.0, !- Minimum Loop Flow Rate {m3/s} AUTOSIZE, !- Plant Loop Volume {m3} SHWSys1 Supply Inlet Node, !- Plant Side Inlet Node Name SHWSys1 Supply Outlet Node, !- Plant Side Outlet Node Name SHWSys1 Supply Branches, !- Plant Side Branch List Name SHWSys1 Supply Connectors, !- Plant Side Connector List Name SHWSys1 Demand Inlet Node, !- Demand Side Inlet Node Name SHWSys1 Demand Outlet Node, !- Demand Side Outlet Node Name SHWSys1 Demand Branches, !- Demand Side Branch List Name SHWSys1 Demand Connectors, !- Demand Side Connector List Name Optimal; !- Load Distribution Scheme PlantLoop, HeatSys1, !- Name WATER, !- Fluid Type , !- User Defined Fluid Type HeatSys1 Loop Operation Scheme List, !- Plant Equipment Operation Scheme Name HeatSys1 Supply Outlet Node, !- Loop Temperature Setpoint Node Name 100.0, !- Maximum Loop Temperature {C} 10.0, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0.0, !- Minimum Loop Flow Rate {m3/s} AUTOSIZE, !- Plant Loop Volume {m3} HeatSys1 Supply Inlet Node, !- Plant Side Inlet Node Name HeatSys1 Supply Outlet Node, !- Plant Side Outlet Node Name HeatSys1 Supply Branches,!- Plant Side Branch List Name HeatSys1 Supply Connectors, !- Plant Side Connector List Name HeatSys1 Demand Inlet Node, !- Demand Side Inlet Node Name HeatSys1 Demand Outlet Node, !- Demand Side Outlet Node Name HeatSys1 Demand Branches,!- Demand Side Branch List Name HeatSys1 Demand Connectors, !- Demand Side Connector List Name Optimal; !- Load Distribution Scheme PlantLoop, CoolSys1_Supply, !- Name WATER, !- Fluid Type , !- User Defined Fluid Type CoolSys1 Loop Operation Scheme List, !- Plant Equipment Operation Scheme Name CoolSys1 Supply Outlet Node, !- Loop Temperature Setpoint Node Name 98.0, !- Maximum Loop Temperature {C} 1.0, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0.0, !- Minimum Loop Flow Rate {m3/s} autocalculate, !- Plant Loop Volume {m3} CoolSys1 Supply Inlet Node, !- Plant Side Inlet Node Name CoolSys1 Supply Outlet Node, !- Plant Side Outlet Node Name CoolSys1 Supply Supply Side Branches, !- Plant Side Branch List Name CoolSys1 Supply Supply Side Connectors, !- Plant Side Connector List Name CoolSys1 Supply Demand Side Inlet Pipe Inlet Node, !- Demand Side Inlet Node Name CoolSys1 Supply Demand Side Outlet Pipe Outlet Node, !- Demand Side Outlet Node Name CoolSys1 Supply Demand Side Branches, !- Demand Side Branch List Name CoolSys1 Supply Demand Side Connectors, !- Demand Side Connector List Name UniformLoad; !- Load Distribution Scheme PlantLoop, CoolSys1_Demand, !- Name Water, !- Fluid Type , !- User Defined Fluid Type CoolSys1 Sec Loop Operation, !- Plant Equipment Operation Scheme Name CoolSys1 Demand Inlet Node, !- Loop Temperature Setpoint Node Name 98, !- Maximum Loop Temperature {C} 1, !- Minimum Loop Temperature {C} autosize, !- Maximum Loop Flow Rate {m3/s} 0, !- Minimum Loop Flow Rate {m3/s} autocalculate, !- Plant Loop Volume {m3} CoolSys1 Demand Supply Side Inlet Pipe Inlet Node, !- Plant Side Inlet Node Name CoolSys1 Demand Supply Side Outlet Pipe Outlet Node, !- Plant Side Outlet Node Name CoolSys1 Demand Supply Side Branches, !- Plant Side Branch List Name CoolSys1 Demand Supply Side Connectors, !- Plant Side Connector List Name CoolSys1 Demand Inlet Node, !- Demand Side Inlet Node Name CoolSys1 Demand Outlet Node, !- Demand Side Outlet Node Name CoolSys1 Demand Demand Side Branches, !- Demand Side Branch List Name CoolSys1 Demand Demand Side Connectors, !- Demand Side Connector List Name UniformLoad; !- Load Distribution Scheme PlantLoop, Single Water Plant Loop, !- Name UserDefinedFluidType, !- Fluid Type EthyleneGlycol40Percent, !- User Defined Fluid Type Plant Loop Operation, !- Plant Equipment Operation Scheme Name Plant Supply Outlet Node,!- Loop Temperature Setpoint Node Name 35, !- Maximum Loop Temperature {C} 10, !- Minimum Loop Temperature {C} autosize, !- Maximum Loop Flow Rate {m3/s} 0, !- Minimum Loop Flow Rate {m3/s} autocalculate, !- Plant Loop Volume {m3} Plant Supply Inlet Node, !- Plant Side Inlet Node Name Plant Supply Outlet Node,!- Plant Side Outlet Node Name Plant Supply Side Branches, !- Plant Side Branch List Name Plant Supply Side Connectors, !- Plant Side Connector List Name Plant Demand Inlet Node, !- Demand Side Inlet Node Name Plant Demand Outlet Node,!- Demand Side Outlet Node Name Plant Demand Side Branches, !- Demand Side Branch List Name Plant Demand Side Connectors, !- Demand Side Connector List Name SequentialLoad, !- Load Distribution Scheme , !- Availability Manager List Name DualSetpointDeadband; !- Plant Loop Demand Calculation Scheme !- =========== ALL OBJECTS IN CLASS: CONDENSER LOOP =========== !- Minimum and maximum Loop Temperatures are relaxed and not used to set the control or sizing limits. CondenserLoop, TowerWaterSys, !- Name Water, !- Fluid Type , !- User Defined Fluid Type TowerWaterSys Loop Operation Scheme List, !- Condenser Equipment Operation Scheme Name TowerWaterSys Supply Outlet Node, !- Condenser Loop Temperature Setpoint Node Name 80.0, !- Maximum Loop Temperature {C} 5.0, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0.0, !- Minimum Loop Flow Rate {m3/s} AUTOSIZE, !- Condenser Loop Volume {m3} TowerWaterSys Supply Inlet Node, !- Condenser Side Inlet Node Name TowerWaterSys Supply Outlet Node, !- Condenser Side Outlet Node Name TowerWaterSys Supply Branches, !- Condenser Side Branch List Name TowerWaterSys Supply Connectors, !- Condenser Side Connector List Name TowerWaterSys Demand Inlet Node, !- Demand Side Inlet Node Name TowerWaterSys Demand Outlet Node, !- Demand Side Outlet Node Name TowerWaterSys Demand Branches, !- Condenser Demand Side Branch List Name TowerWaterSys Demand Connectors, !- Condenser Demand Side Connector List Name SequentialLoad; !- Load Distribution Scheme !- =========== ALL OBJECTS IN CLASS: PLANT OPERATION SCHEMES =========== PlantEquipmentOperationSchemes, SHWSys1 Loop Operation Scheme List, !- Name PlantEquipmentOperation:HeatingLoad, !- Control Scheme 1 Object Type SHWSys1 Operation Scheme,!- Control Scheme 1 Name PlantOnSched; !- Control Scheme 1 Schedule Name PlantEquipmentOperationSchemes, HeatSys1 Loop Operation Scheme List, !- Name PlantEquipmentOperation:HeatingLoad, !- Control Scheme 1 Object Type HeatSys1 Operation Scheme, !- Control Scheme 1 Name PlantOnSched; !- Control Scheme 1 Schedule Name PlantEquipmentOperationSchemes, CoolSys1 Loop Operation Scheme List, !- Name PlantEquipmentOperation:CoolingLoad, !- Control Scheme 1 Object Type CoolSys1 Operation Scheme, !- Control Scheme 1 Name PlantOnSched; !- Control Scheme 1 Schedule Name PlantEquipmentOperationSchemes, CoolSys1 Sec Loop Operation, !- Name PlantEquipmentOperation:CoolingLoad, !- Control Scheme 1 Object Type CoolSys1 Sec Operation Scheme, !- Control Scheme 1 Name PlantOnSched; !- Control Scheme 1 Schedule Name PlantEquipmentOperationSchemes, Plant Loop Operation, !- Name PlantEquipmentOperation:ComponentSetpoint, !- Control Scheme 1 Object Type WSHPPlant Operation Scheme, !- Control Scheme 1 Name Always_On; !- Control Scheme 1 Schedule Name !- =========== ALL OBJECTS IN CLASS: CONDENSER OPERATION SCHEMES =========== CondenserEquipmentOperationSchemes, TowerWaterSys Loop Operation Scheme List, !- Name PlantEquipmentOperation:CoolingLoad, !- Control Scheme 1 Object Type TowerWaterSys Operation Scheme, !- Control Scheme 1 Name PlantOnSched; !- Control Scheme 1 Schedule Name !- =========== ALL OBJECTS IN CLASS: COOLING LOAD RANGE BASED OPERATION =========== PlantEquipmentOperation:CoolingLoad, CoolSys1 Operation Scheme, !- Name 0.0, !- Load Range 1 Lower Limit {W} 1302254.38, !- Load Range 1 Upper Limit {W} CoolSys1 Equipment List 1, !- Range 1 Equipment List Name 1302254.38, !- Load Range 2 Lower Limit {W} 100000000000000, !- Load Range 2 Upper Limit {W} CoolSys1 Equipment List 2; !- Range 2 Equipment List Name PlantEquipmentOperation:CoolingLoad, CoolSys1 Sec Operation Scheme, !- Name 0, !- Load Range 1 Lower Limit {W} 1302254.38, !- Load Range 1 Upper Limit {W} CoolSys1 HeatExchanger; !- Range 1 Equipment List Name PlantEquipmentOperation:CoolingLoad, TowerWaterSys Operation Scheme, !- Name 0.0, !- Load Range 1 Lower Limit {W} 1302254.38, !- Load Range 1 Upper Limit {W} TowerWaterSys Equipment List 1, !- Range 1 Equipment List Name 1302254.38, !- Load Range 2 Lower Limit {W} 100000000000000, !- Load Range 2 Upper Limit {W} TowerWaterSys Equipment List 2; !- Range 2 Equipment List Name !- =========== ALL OBJECTS IN CLASS: HEATING LOAD RANGE BASED OPERATION =========== PlantEquipmentOperation:HeatingLoad, SHWSys1 Operation Scheme,!- Name 0.0, !- Load Range 1 Lower Limit {W} 1000000000000000, !- Load Range 1 Upper Limit {W} SHWSys1 Equipment List; !- Range 1 Equipment List Name PlantEquipmentOperation:HeatingLoad, HeatSys1 Operation Scheme, !- Name 0.0, !- Load Range 1 Lower Limit {W} 1000000000000000, !- Load Range 1 Upper Limit {W} HeatSys1 Equipment List; !- Range 1 Equipment List Name !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTOPERATION:COMPONENTSETPOINT =========== PlantEquipmentOperation:ComponentSetpoint, WSHPPlant Operation Scheme, !- Name FluidCooler:TwoSpeed, !- Equipment 1 Object Type Central Tower, !- Equipment 1 Name Central Tower Inlet Node,!- Demand Calculation 1 Node Name Plant Supply Outlet Node,!- Setpoint 1 Node Name autosize, !- Component 1 Flow Rate {m3/s} Cooling, !- Operation 1 Type Boiler:HotWater, !- Equipment 2 Object Type Dummy Boiler, !- Equipment 2 Name Dummy Boiler Inlet Node, !- Demand Calculation 2 Node Name Plant Supply Outlet Node,!- Setpoint 2 Node Name autosize, !- Component 2 Flow Rate {m3/s} Heating; !- Operation 2 Type !- =========== ALL OBJECTS IN CLASS: PLANT EQUIPMENT LIST =========== PlantEquipmentList, SHWSys1 Equipment List, !- Name WaterHeater:Mixed, !- Equipment 1 Object Type SHWSys1 Water Heater; !- Equipment 1 Name PlantEquipmentList, HeatSys1 Equipment List, !- Name Boiler:HotWater, !- Equipment 1 Object Type HeatSys1 Boiler; !- Equipment 1 Name PlantEquipmentList, CoolSys1 Equipment List 1, !- Name Chiller:Electric:ReformulatedEIR, !- Equipment 1 Object Type CoolSys1 Chiller1; !- Equipment 1 Name PlantEquipmentList, CoolSys1 Equipment List 2, !- Name Chiller:Electric:ReformulatedEIR, !- Equipment 1 Object Type CoolSys1 Chiller1, !- Equipment 1 Name Chiller:Electric:ReformulatedEIR, !- Equipment 2 Object Type CoolSys1 Chiller2; !- Equipment 2 Name PlantEquipmentList, CoolSys1 HeatExchanger, !- Name HeatExchanger:FluidToFluid, !- Equipment 1 Object Type Bypass Heat exchanger; !- Equipment 1 Name !- =========== ALL OBJECTS IN CLASS: CONDENSER EQUIPMENT LIST =========== CondenserEquipmentList, TowerWaterSys Equipment List 1, !- Name CoolingTower:VariableSpeed, !- Equipment 1 Object Type TowerWaterSys CoolTower 1; !- Equipment 1 Name CondenserEquipmentList, TowerWaterSys Equipment List 2, !- Name CoolingTower:VariableSpeed, !- Equipment 1 Object Type TowerWaterSys CoolTower 1, !- Equipment 1 Name CoolingTower:VariableSpeed, !- Equipment 2 Object Type TowerWaterSys CoolTower 2; !- Equipment 2 Name !- =========== ALL OBJECTS IN CLASS: SPLITTER =========== Connector:Splitter, SHWSys1 Supply Splitter, !- Name SHWSys1 Supply Inlet Branch, !- Inlet Branch Name SHWSys1 Supply Equipment Branch, !- Outlet Branch 1 Name SHWSys1 Supply Equipment Bypass Branch; !- Outlet Branch 2 Name Connector:Splitter, SHWSys1 Demand Splitter, !- Name SHWSys1 Demand Inlet Branch, !- Inlet Branch Name SHWSys1 Demand Load Branch 1, !- Outlet Branch 1 Name SHWSys1 Demand Load Branch 2, !- Outlet Branch 2 Name SHWSys1 Demand Load Branch 3, !- Outlet Branch 3 Name SHWSys1 Demand Bypass Branch; !- Outlet Branch 4 Name Connector:Splitter, HeatSys1 Supply Splitter,!- Name HeatSys1 Supply Inlet Branch, !- Inlet Branch Name HeatSys1 Supply Equipment Branch, !- Outlet Branch 1 Name HeatSys1 Supply Equipment Bypass Branch; !- Outlet Branch 2 Name Connector:Splitter, HeatSys1 Demand Splitter,!- Name HeatSys1 Demand Inlet Branch, !- Inlet Branch Name HeatSys1 Demand Load Branch 1, !- Outlet Branch 1 Name HeatSys1 Demand Load Branch 2, !- Outlet Branch 2 Name HeatSys1 Demand Load Branch 3, !- Outlet Branch 3 Name HeatSys1 Demand Load Branch 4, !- Outlet Branch 4 Name HeatSys1 Demand Load Branch 5, !- Outlet Branch 5 Name HeatSys1 Demand Load Branch 6, !- Outlet Branch 6 Name HeatSys1 Demand Load Branch 7, !- Outlet Branch 7 Name HeatSys1 Demand Load Branch 8, !- Outlet Branch 8 Name HeatSys1 Demand Load Branch 9, !- Outlet Branch 9 Name HeatSys1 Demand Load Branch 10, !- Outlet Branch 10 Name HeatSys1 Demand Load Branch 11, !- Outlet Branch 11 Name HeatSys1 Demand Load Branch 12, !- Outlet Branch 12 Name HeatSys1 Demand Load Branch 13, !- Outlet Branch 13 Name HeatSys1 Demand Load Branch 14, !- Outlet Branch 14 Name HeatSys1 Demand Load Branch 15, !- Outlet Branch 15 Name HeatSys1 Demand Load Branch 17, !- Outlet Branch 16 Name HeatSys1 Demand Load Branch 18, !- Outlet Branch 17 Name HeatSys1 Demand Load Branch 19, !- Outlet Branch 18 Name HeatSys1 Demand Load Branch 20, !- Outlet Branch 19 Name HeatSys1 Demand Load Branch 21, !- Outlet Branch 20 Name HeatSys1 Demand Bypass Branch; !- Outlet Branch 21 Name Connector:Splitter, CoolSys1 Supply Supply Side Splitter,!- Name CoolSys1 Supply Inlet Branch, !- Inlet Branch Name CoolSys1 Supply Equipment Branch 1, !- Outlet Branch 1 Name CoolSys1 Supply Equipment Branch 2, !- Outlet Branch 2 Name CoolSys1 Supply Equipment Bypass Branch; !- Outlet Branch 3 Name Connector:Splitter, CoolSys1 Demand Demand Side Splitter,!- Name CoolSys1 Demand Inlet Branch, !- Inlet Branch Name CoolSys1 Demand Load Branch 1, !- Outlet Branch 1 Name CoolSys1 Demand Load Branch 2, !- Outlet Branch 2 Name CoolSys1 Demand Load Branch 3, !- Outlet Branch 3 Name CoolSys1 Demand Load Branch 4; !- Outlet Branch 4 Name Connector:Splitter, TowerWaterSys Supply Splitter, !- Name TowerWaterSys Supply Inlet Branch, !- Inlet Branch Name TowerWaterSys Supply Equipment Branch 1, !- Outlet Branch 1 Name TowerWaterSys Supply Equipment Branch 2, !- Outlet Branch 2 Name TowerWaterSys Supply Equipment Bypass Branch; !- Outlet Branch 3 Name Connector:Splitter, TowerWaterSys Demand Splitter, !- Name TowerWaterSys Demand Inlet Branch, !- Inlet Branch Name TowerWaterSys Demand Load Branch 1, !- Outlet Branch 1 Name TowerWaterSys Demand Load Branch 2, !- Outlet Branch 2 Name TowerWaterSys Demand Bypass Branch; !- Outlet Branch 3 Name Connector:Splitter, CoolSys1 Supply Demand Side Splitter, !- Name CoolSys1 Supply Demand Side Inlet Branch, !- Inlet Branch Name CoolSys1 Heat Exchanger Supply Branch, !- Outlet Branch 1 Name CoolSys1 Supply Side Bypass; !- Outlet Branch 2 Name Connector:Splitter, CoolSys1 Demand Supply Side Splitter, !- Name CoolSys1 Demand Supply Side Inlet Branch, !- Inlet Branch Name CoolSys1 Heat Exchanger Demand Branch, !- Outlet Branch 1 Name CoolSys1 Demand Side Bypass; !- Outlet Branch 2 Name Connector:Splitter, Plant Supply Splitter, !- Name Plant Supply Inlet Branch, !- Inlet Branch Name Plant Supply Tower Branch, !- Outlet Branch 1 Name Dummy Boiler Branch, !- Outlet Branch 2 Name Plant Supply Bypass Branch; !- Outlet Branch 3 Name Connector:Splitter, Plant Demand Splitter, !- Name Plant Demand Inlet Branch, !- Inlet Branch Name WLHP Cooling Plant Branch AirLoop DataCenter Basement, !- Outlet Branch 1 Name WLHP Heating Plant Branch AirLoop DataCenter Basement, !- Outlet Branch 2 Name WLHP Cooling Plant Branch AirLoop DataCenter bot, !- Outlet Branch 3 Name WLHP Heating Plant Branch AirLoop DataCenter bot, !- Outlet Branch 4 Name WLHP Cooling Plant Branch AirLoop DataCenter mid, !- Outlet Branch 5 Name WLHP Heating Plant Branch AirLoop DataCenter mid, !- Outlet Branch 6 Name WLHP Cooling Plant Branch AirLoop DataCenter top, !- Outlet Branch 7 Name WLHP Heating Plant Branch AirLoop DataCenter top, !- Outlet Branch 8 Name Plant Demand Bypass Branch; !- Outlet Branch 9 Name !- =========== ALL OBJECTS IN CLASS: MIXER =========== Connector:Mixer, SHWSys1 Supply Mixer, !- Name SHWSys1 Supply Outlet Branch, !- Outlet Branch Name SHWSys1 Supply Equipment Branch, !- Inlet Branch 1 Name SHWSys1 Supply Equipment Bypass Branch; !- Inlet Branch 2 Name Connector:Mixer, SHWSys1 Demand Mixer, !- Name SHWSys1 Demand Outlet Branch, !- Outlet Branch Name SHWSys1 Demand Load Branch 1, !- Inlet Branch 1 Name SHWSys1 Demand Load Branch 2, !- Inlet Branch 2 Name SHWSys1 Demand Load Branch 3, !- Inlet Branch 3 Name SHWSys1 Demand Bypass Branch; !- Inlet Branch 4 Name Connector:Mixer, HeatSys1 Supply Mixer, !- Name HeatSys1 Supply Outlet Branch, !- Outlet Branch Name HeatSys1 Supply Equipment Branch, !- Inlet Branch 1 Name HeatSys1 Supply Equipment Bypass Branch; !- Inlet Branch 2 Name Connector:Mixer, HeatSys1 Demand Mixer, !- Name HeatSys1 Demand Outlet Branch, !- Outlet Branch Name HeatSys1 Demand Load Branch 1, !- Inlet Branch 1 Name HeatSys1 Demand Load Branch 2, !- Inlet Branch 2 Name HeatSys1 Demand Load Branch 3, !- Inlet Branch 3 Name HeatSys1 Demand Load Branch 4, !- Inlet Branch 4 Name HeatSys1 Demand Load Branch 5, !- Inlet Branch 5 Name HeatSys1 Demand Load Branch 6, !- Inlet Branch 6 Name HeatSys1 Demand Load Branch 7, !- Inlet Branch 7 Name HeatSys1 Demand Load Branch 8, !- Inlet Branch 8 Name HeatSys1 Demand Load Branch 9, !- Inlet Branch 9 Name HeatSys1 Demand Load Branch 10, !- Inlet Branch 10 Name HeatSys1 Demand Load Branch 11, !- Inlet Branch 11 Name HeatSys1 Demand Load Branch 12, !- Inlet Branch 12 Name HeatSys1 Demand Load Branch 13, !- Inlet Branch 13 Name HeatSys1 Demand Load Branch 14, !- Inlet Branch 14 Name HeatSys1 Demand Load Branch 15, !- Inlet Branch 15 Name HeatSys1 Demand Load Branch 17, !- Inlet Branch 16 Name HeatSys1 Demand Load Branch 18, !- Inlet Branch 17 Name HeatSys1 Demand Load Branch 19, !- Inlet Branch 18 Name HeatSys1 Demand Load Branch 20, !- Inlet Branch 19 Name HeatSys1 Demand Load Branch 21, !- Inlet Branch 20 Name HeatSys1 Demand Bypass Branch; !- Inlet Branch 21 Name Connector:Mixer, CoolSys1 Supply Supply Side Mixer, !- Name CoolSys1 Supply Outlet Branch, !- Outlet Branch Name CoolSys1 Supply Equipment Branch 1, !- Inlet Branch 1 Name CoolSys1 Supply Equipment Branch 2, !- Inlet Branch 2 Name CoolSys1 Supply Equipment Bypass Branch; !- Inlet Branch 3 Name Connector:Mixer, CoolSys1 Demand Demand Side Mixer, !- Name CoolSys1 Demand Outlet Branch, !- Outlet Branch Name CoolSys1 Demand Load Branch 1, !- Inlet Branch 1 Name CoolSys1 Demand Load Branch 2, !- Inlet Branch 2 Name CoolSys1 Demand Load Branch 3, !- Inlet Branch 3 Name CoolSys1 Demand Load Branch 4; !- Inlet Branch 4 Name Connector:Mixer, TowerWaterSys Supply Mixer, !- Name TowerWaterSys Supply Outlet Branch, !- Outlet Branch Name TowerWaterSys Supply Equipment Branch 1, !- Inlet Branch 1 Name TowerWaterSys Supply Equipment Branch 2, !- Inlet Branch 2 Name TowerWaterSys Supply Equipment Bypass Branch; !- Inlet Branch 3 Name Connector:Mixer, TowerWaterSys Demand Mixer, !- Name TowerWaterSys Demand Outlet Branch, !- Outlet Branch Name TowerWaterSys Demand Load Branch 1, !- Inlet Branch 1 Name TowerWaterSys Demand Load Branch 2, !- Inlet Branch 2 Name TowerWaterSys Demand Bypass Branch; !- Inlet Branch 3 Name Connector:Mixer, CoolSys1 Supply Demand Side Mixer, !- Name CoolSys1 Supply Demand Side Outlet Branch, !- Outlet Branch Name CoolSys1 Heat Exchanger Supply Branch, !- Inlet Branch 1 Name CoolSys1 Supply Side Bypass; !- Inlet Branch 2 Name Connector:Mixer, CoolSys1 Demand Supply Side Mixer, !- Name CoolSys1 Demand Supply Side Outlet Branch, !- Outlet Branch Name CoolSys1 Heat Exchanger Demand Branch, !- Inlet Branch 1 Name CoolSys1 Demand Side Bypass; !- Inlet Branch 2 Name Connector:Mixer, Plant Supply Mixer, !- Name Plant Supply Outlet Branch, !- Outlet Branch Name Plant Supply Tower Branch, !- Inlet Branch 1 Name Dummy Boiler Branch, !- Inlet Branch 2 Name Plant Supply Bypass Branch; !- Inlet Branch 3 Name Connector:Mixer, Plant Demand Mixer, !- Name Plant Demand Outlet Branch, !- Outlet Branch Name WLHP Cooling Plant Branch AirLoop DataCenter Basement, !- Inlet Branch 1 Name WLHP Heating Plant Branch AirLoop DataCenter Basement, !- Inlet Branch 2 Name WLHP Cooling Plant Branch AirLoop DataCenter bot, !- Inlet Branch 3 Name WLHP Heating Plant Branch AirLoop DataCenter bot, !- Inlet Branch 4 Name WLHP Cooling Plant Branch AirLoop DataCenter mid, !- Inlet Branch 5 Name WLHP Heating Plant Branch AirLoop DataCenter mid, !- Inlet Branch 6 Name WLHP Cooling Plant Branch AirLoop DataCenter top, !- Inlet Branch 7 Name WLHP Heating Plant Branch AirLoop DataCenter top, !- Inlet Branch 8 Name Plant Demand Bypass Branch; !- Inlet Branch 9 Name !- =========== ALL OBJECTS IN CLASS: AIR PRIMARY LOOP =========== AirLoopHVAC, CAV_bas, !- Name CAV_bas_Controllers, !- Controller List Name CAV_bas Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} CAV_bas Air Loop Branches, !- Branch List Name , !- Connector List Name CAV_bas Supply Equipment Inlet Node, !- Supply Side Inlet Node Name CAV_bas Zone Equipment Outlet Node, !- Demand Side Outlet Node Name CAV_bas Zone Equipment Inlet Node, !- Demand Side Inlet Node Names CAV_bas Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, VAV_bot WITH REHEAT, !- Name VAV_bot WITH REHEAT_Controllers, !- Controller List Name VAV_bot WITH REHEAT Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} VAV_bot WITH REHEAT Air Loop Branches, !- Branch List Name , !- Connector List Name VAV_bot WITH REHEAT Supply Equipment Inlet Node, !- Supply Side Inlet Node Name VAV_bot WITH REHEAT Zone Equipment Outlet Node, !- Demand Side Outlet Node Name VAV_bot WITH REHEAT Zone Equipment Inlet Node, !- Demand Side Inlet Node Names VAV_bot WITH REHEAT Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, VAV_mid WITH REHEAT, !- Name VAV_mid WITH REHEAT_Controllers, !- Controller List Name VAV_mid WITH REHEAT Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} VAV_mid WITH REHEAT Air Loop Branches, !- Branch List Name , !- Connector List Name VAV_mid WITH REHEAT Supply Equipment Inlet Node, !- Supply Side Inlet Node Name VAV_mid WITH REHEAT Zone Equipment Outlet Node, !- Demand Side Outlet Node Name VAV_mid WITH REHEAT Zone Equipment Inlet Node, !- Demand Side Inlet Node Names VAV_mid WITH REHEAT Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, VAV_top WITH REHEAT, !- Name VAV_top WITH REHEAT_Controllers, !- Controller List Name VAV_top WITH REHEAT Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} VAV_top WITH REHEAT Air Loop Branches, !- Branch List Name , !- Connector List Name VAV_top WITH REHEAT Supply Equipment Inlet Node, !- Supply Side Inlet Node Name VAV_top WITH REHEAT Zone Equipment Outlet Node, !- Demand Side Outlet Node Name VAV_top WITH REHEAT Zone Equipment Inlet Node, !- Demand Side Inlet Node Names VAV_top WITH REHEAT Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, AirLoop DataCenter Basement, !- Name DataCenter_bas_HeatC_Controllers, !- Controller List Name AirLoop DataCenter Basement Availability Manager, !- Availability Manager List Name autosize, !- Design Supply Air Flow Rate {m3/s} AirLoop DataCenter Basement Branches, !- Branch List Name , !- Connector List Name AirLoop DataCenter Basement Return Air Inlet, !- Supply Side Inlet Node Name ZoneMixer DataCenter Basement Return Air Outlet, !- Demand Side Outlet Node Name ZoneSplitter DataCenter Basement Supply Air Inlet, !- Demand Side Inlet Node Names AirLoop DataCenter Basement Supply Air Outlet; !- Supply Side Outlet Node Names AirLoopHVAC, AirLoop DataCenter bot, !- Name , !- Controller List Name AirLoop DataCenter bot Availability Manager, !- Availability Manager List Name autosize, !- Design Supply Air Flow Rate {m3/s} AirLoop DataCenter bot Branches, !- Branch List Name , !- Connector List Name AirLoop DataCenter bot Return Air Inlet, !- Supply Side Inlet Node Name ZoneMixer DataCenter bot Return Air Outlet, !- Demand Side Outlet Node Name ZoneSplitter DataCenter bot Supply Air Inlet, !- Demand Side Inlet Node Names AirLoop DataCenter bot Supply Air Outlet; !- Supply Side Outlet Node Names AirLoopHVAC, AirLoop DataCenter mid, !- Name , !- Controller List Name AirLoop DataCenter mid Availability Manager, !- Availability Manager List Name autosize, !- Design Supply Air Flow Rate {m3/s} AirLoop DataCenter mid Branches, !- Branch List Name , !- Connector List Name AirLoop DataCenter mid Return Air Inlet, !- Supply Side Inlet Node Name ZoneMixer DataCenter mid Return Air Outlet, !- Demand Side Outlet Node Name ZoneSplitter DataCenter mid Supply Air Inlet, !- Demand Side Inlet Node Names AirLoop DataCenter mid Supply Air Outlet; !- Supply Side Outlet Node Names AirLoopHVAC, AirLoop DataCenter top, !- Name , !- Controller List Name AirLoop DataCenter top Availability Manager, !- Availability Manager List Name autosize, !- Design Supply Air Flow Rate {m3/s} AirLoop DataCenter top Branches, !- Branch List Name , !- Connector List Name AirLoop DataCenter top Return Air Inlet, !- Supply Side Inlet Node Name ZoneMixer DataCenter top Return Air Outlet, !- Demand Side Outlet Node Name ZoneSplitter DataCenter top Supply Air Inlet, !- Demand Side Inlet Node Names AirLoop DataCenter top Supply Air Outlet; !- Supply Side Outlet Node Names !- =========== ALL OBJECTS IN CLASS: CONTROLLER LIST =========== AirLoopHVAC:ControllerList, DataCenter_bas_HeatC_Controllers, !- Name Controller:WaterCoil, !- Controller 1 Object Type DataCenter_bas_HeatC_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, CAV_bas_Controllers, !- Name Controller:WaterCoil, !- Controller 1 Object Type CAV_bas_CoolC_Controller,!- Controller 1 Name Controller:WaterCoil, !- Controller 2 Object Type CAV_bas_HeatC_Controller;!- Controller 2 Name AirLoopHVAC:ControllerList, VAV_bot WITH REHEAT_Controllers, !- Name Controller:WaterCoil, !- Controller 1 Object Type VAV_bot WITH REHEAT_CoolC_Controller, !- Controller 1 Name Controller:WaterCoil, !- Controller 2 Object Type VAV_bot WITH REHEAT_HeatC_Controller; !- Controller 2 Name AirLoopHVAC:ControllerList, VAV_mid WITH REHEAT_Controllers, !- Name Controller:WaterCoil, !- Controller 1 Object Type VAV_mid WITH REHEAT_CoolC_Controller, !- Controller 1 Name Controller:WaterCoil, !- Controller 2 Object Type VAV_mid WITH REHEAT_HeatC_Controller; !- Controller 2 Name AirLoopHVAC:ControllerList, VAV_top WITH REHEAT_Controllers, !- Name Controller:WaterCoil, !- Controller 1 Object Type VAV_top WITH REHEAT_CoolC_Controller, !- Controller 1 Name Controller:WaterCoil, !- Controller 2 Object Type VAV_top WITH REHEAT_HeatC_Controller; !- Controller 2 Name AirLoopHVAC:ControllerList, CAV_bas_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type CAV_bas_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, VAV_bot WITH REHEAT_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type VAV_bot WITH REHEAT_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, VAV_mid WITH REHEAT_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type VAV_mid WITH REHEAT_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, VAV_top WITH REHEAT_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type VAV_top WITH REHEAT_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, AirLoop DataCenter Basement OA System Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type AirLoop DataCenter Basement OA Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, AirLoop DataCenter bot OA System Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type AirLoop DataCenter bot OA Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, AirLoop DataCenter mid OA System Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type AirLoop DataCenter mid OA Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, AirLoop DataCenter top OA System Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type AirLoop DataCenter top OA Controller; !- Controller 1 Name !- =========== ALL OBJECTS IN CLASS: AIR LOOP EQUIPMENT LIST =========== AirLoopHVAC:OutdoorAirSystem:EquipmentList, CAV_bas_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type CAV_bas_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, VAV_bot WITH REHEAT_OA_Equipment, !- Name HeatExchanger:AirToAir:SensibleAndLatent, !- Component 1 Object Type VAV_bot WITH REHEAT OA Heat Recovery, !- Component 1 Name OutdoorAir:Mixer, !- Component 2 Object Type VAV_bot WITH REHEAT_OAMixing Box; !- Component 2 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, VAV_mid WITH REHEAT_OA_Equipment, !- Name HeatExchanger:AirToAir:SensibleAndLatent, !- Component 1 Object Type VAV_mid WITH REHEAT OA Heat Recovery, !- Component 1 Name OutdoorAir:Mixer, !- Component 2 Object Type VAV_mid WITH REHEAT_OAMixing Box; !- Component 2 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, VAV_top WITH REHEAT_OA_Equipment, !- Name HeatExchanger:AirToAir:SensibleAndLatent, !- Component 1 Object Type VAV_top WITH REHEAT OA Heat Recovery, !- Component 1 Name OutdoorAir:Mixer, !- Component 2 Object Type VAV_top WITH REHEAT_OAMixing Box; !- Component 2 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, AirLoop DataCenter Basement OA System Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type DataCenter Basement OA Mixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, AirLoop DataCenter bot OA System Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type DataCenter bot OA Mixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, AirLoop DataCenter mid OA System Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type DataCenter mid OA Mixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, AirLoop DataCenter top OA System Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type DataCenter top OA Mixing Box; !- Component 1 Name !- =========== ALL OBJECTS IN CLASS: OUTSIDE AIR SYSTEM =========== AirLoopHVAC:OutdoorAirSystem, CAV_bas_OA, !- Name CAV_bas_OA_Controllers, !- Controller List Name CAV_bas_OA_Equipment, !- Outdoor Air Equipment List Name CAV_bas Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, VAV_bot WITH REHEAT_OA, !- Name VAV_bot WITH REHEAT_OA_Controllers, !- Controller List Name VAV_bot WITH REHEAT_OA_Equipment, !- Outdoor Air Equipment List Name VAV_bot WITH REHEAT Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, VAV_mid WITH REHEAT_OA, !- Name VAV_mid WITH REHEAT_OA_Controllers, !- Controller List Name VAV_mid WITH REHEAT_OA_Equipment, !- Outdoor Air Equipment List Name VAV_mid WITH REHEAT Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, VAV_top WITH REHEAT_OA, !- Name VAV_top WITH REHEAT_OA_Controllers, !- Controller List Name VAV_top WITH REHEAT_OA_Equipment, !- Outdoor Air Equipment List Name VAV_top WITH REHEAT Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, AirLoop DataCenter Basement OA System, !- Name AirLoop DataCenter Basement OA System Controllers, !- Controller List Name AirLoop DataCenter Basement OA System Equipment, !- Outdoor Air Equipment List Name AirLoop DataCenter Basement Availability Manager; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, AirLoop DataCenter bot OA System, !- Name AirLoop DataCenter bot OA System Controllers, !- Controller List Name AirLoop DataCenter bot OA System Equipment, !- Outdoor Air Equipment List Name AirLoop DataCenter bot Availability Manager; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, AirLoop DataCenter mid OA System, !- Name AirLoop DataCenter mid OA System Controllers, !- Controller List Name AirLoop DataCenter mid OA System Equipment, !- Outdoor Air Equipment List Name AirLoop DataCenter mid Availability Manager; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, AirLoop DataCenter top OA System, !- Name AirLoop DataCenter top OA System Controllers, !- Controller List Name AirLoop DataCenter top OA System Equipment, !- Outdoor Air Equipment List Name AirLoop DataCenter top Availability Manager; !- Availability Manager List Name !- =========== ALL OBJECTS IN CLASS: OUTSIDE AIR INLET NODE LIST =========== OutdoorAir:NodeList, CAV_bas_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, VAV_bot WITH REHEAT_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, VAV_mid WITH REHEAT_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, VAV_top WITH REHEAT_OANode List; !- Node or NodeList Name 1 OutdoorAir:Node, DataCenter Basement Outside Air Inlet; !- Name OutdoorAir:Node, DataCenter bot Outside Air Inlet; !- Name OutdoorAir:Node, DataCenter mid Outside Air Inlet; !- Name OutdoorAir:Node, DataCenter top Outside Air Inlet; !- Name OutdoorAir:Node, Common OSA Inlet Node, !- Name -1; !- Height Above Ground {m} !- =========== ALL OBJECTS IN CLASS: OUTSIDE AIR MIXER =========== OutdoorAir:Mixer, CAV_bas_OAMixing Box, !- Name CAV_bas_OA-CAV_CoolCNode, !- Mixed Air Node Name CAV_bas_OAInlet Node, !- Outdoor Air Stream Node Name !- Outdoor Air Stream Node Name CAV_bas_OARelief Node, !- Relief Air Stream Node Name CAV_bas Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, VAV_bot WITH REHEAT_OAMixing Box, !- Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Node Name VAV_bot WITH REHEAT Heat Recovery Outlet Node, !- Outdoor Air Stream Node Name !- Outdoor Air Stream Node Name VAV_bot WITH REHEAT_OARelief Node, !- Relief Air Stream Node Name VAV_bot WITH REHEAT Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, VAV_mid WITH REHEAT_OAMixing Box, !- Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Node Name VAV_mid WITH REHEAT Heat Recovery Outlet Node, !- Outdoor Air Stream Node Name !- Outdoor Air Stream Node Name VAV_mid WITH REHEAT_OARelief Node, !- Relief Air Stream Node Name VAV_mid WITH REHEAT Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, VAV_top WITH REHEAT_OAMixing Box, !- Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Node Name VAV_top WITH REHEAT Heat Recovery Outlet Node, !- Outdoor Air Stream Node Name !- Outdoor Air Stream Node Name VAV_top WITH REHEAT_OARelief Node, !- Relief Air Stream Node Name VAV_top WITH REHEAT Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, DataCenter Basement OA Mixing Box, !- Name DataCenter Basement Mixed Air Outlet, !- Mixed Air Node Name DataCenter Basement Outside Air Inlet, !- Outdoor Air Stream Node Name DataCenter Basement Relief Air Outlet, !- Relief Air Stream Node Name AirLoop DataCenter Basement Return Air Inlet; !- Return Air Stream Node Name OutdoorAir:Mixer, DataCenter bot OA Mixing Box, !- Name DataCenter bot Mixed Air Outlet, !- Mixed Air Node Name DataCenter bot Outside Air Inlet, !- Outdoor Air Stream Node Name DataCenter bot Relief Air Outlet, !- Relief Air Stream Node Name AirLoop DataCenter bot Return Air Inlet; !- Return Air Stream Node Name OutdoorAir:Mixer, DataCenter mid OA Mixing Box, !- Name DataCenter mid Mixed Air Outlet, !- Mixed Air Node Name DataCenter mid Outside Air Inlet, !- Outdoor Air Stream Node Name DataCenter mid Relief Air Outlet, !- Relief Air Stream Node Name AirLoop DataCenter mid Return Air Inlet; !- Return Air Stream Node Name OutdoorAir:Mixer, DataCenter top OA Mixing Box, !- Name DataCenter top Mixed Air Outlet, !- Mixed Air Node Name DataCenter top Outside Air Inlet, !- Outdoor Air Stream Node Name DataCenter top Relief Air Outlet, !- Relief Air Stream Node Name AirLoop DataCenter top Return Air Inlet; !- Return Air Stream Node Name !- =========== ALL OBJECTS IN CLASS: AVAILABILITYMANAGER:SCHEDULED =========== AvailabilityManager:Scheduled, AirLoop DataCenter Basement Availability, !- Name Always_On; !- Schedule Name AvailabilityManager:Scheduled, AirLoop DataCenter bot Availability, !- Name Always_On; !- Schedule Name AvailabilityManager:Scheduled, AirLoop DataCenter mid Availability, !- Name Always_On; !- Schedule Name AvailabilityManager:Scheduled, AirLoop DataCenter top Availability, !- Name Always_On; !- Schedule Name !- =========== ALL OBJECTS IN CLASS: SYSTEM AVAILABILITY MANAGER LIST =========== AvailabilityManagerAssignmentList, CAV_bas Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type CAV_bas Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, VAV_bot WITH REHEAT Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type VAV_bot WITH REHEAT Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, VAV_mid WITH REHEAT Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type VAV_mid WITH REHEAT Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, VAV_top WITH REHEAT Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type VAV_top WITH REHEAT Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, AirLoop DataCenter Basement Availability Manager, !- Name AvailabilityManager:Scheduled, !- Availability Manager 1 Object Type AirLoop DataCenter Basement Availability; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, AirLoop DataCenter bot Availability Manager, !- Name AvailabilityManager:Scheduled, !- Availability Manager 1 Object Type AirLoop DataCenter bot Availability; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, AirLoop DataCenter mid Availability Manager, !- Name AvailabilityManager:Scheduled, !- Availability Manager 1 Object Type AirLoop DataCenter mid Availability; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, AirLoop DataCenter top Availability Manager, !- Name AvailabilityManager:Scheduled, !- Availability Manager 1 Object Type AirLoop DataCenter top Availability; !- Availability Manager 1 Name !- =========== ALL OBJECTS IN CLASS: SYSTEM AVAILABILITY MANAGER:NIGHT CYCLE =========== AvailabilityManager:NightCycle, CAV_bas Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, VAV_bot WITH REHEAT Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, VAV_mid WITH REHEAT Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, VAV_top WITH REHEAT Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:SINGLEZONE:HEATING & COOLING =========== SetpointManager:SingleZone:Heating, CAV_bas SupAirTemp Manager - Htg, !- Name Temperature, !- Control Variable 10, !- Minimum Supply Air Temperature {C} 50, !- Maximum Supply Air Temperature {C} Basement, !- Control Zone Name Basement Air Node, !- Zone Node Name Basement Direct Air Inlet Node Name, !- Zone Inlet Node Name CAV_bas Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, DataCenter Basement SupAirTemp Manager - Htg, !- Name Temperature, !- Control Variable 10, !- Minimum Supply Air Temperature {C} 50, !- Maximum Supply Air Temperature {C} DataCenter_basement_ZN_6,!- Control Zone Name DataCenter Basement Zone Air Node, !- Zone Node Name DataCenter Basement Supply Inlet, !- Zone Inlet Node Name AirLoop DataCenter Basement Supply Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, DataCenter_bot_ZN_6 SupAirTemp Manager - Htg, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} DataCenter_bot_ZN_6, !- Control Zone Name DataCenter bot Zone Air Node, !- Zone Node Name DataCenter bot Supply Inlet, !- Zone Inlet Node Name AirLoop DataCenter bot Supply Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, DataCenter_mid_ZN_6 SupAirTemp Manager - Htg, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} DataCenter_mid_ZN_6, !- Control Zone Name DataCenter mid Zone Air Node, !- Zone Node Name DataCenter mid Supply Inlet, !- Zone Inlet Node Name AirLoop DataCenter mid Supply Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, DataCenter_top_ZN_6 SupAirTemp Manager - Htg, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} DataCenter_top_ZN_6, !- Control Zone Name DataCenter top Zone Air Node, !- Zone Node Name DataCenter top Supply Inlet, !- Zone Inlet Node Name AirLoop DataCenter top Supply Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, CAV_bas SupAirTemp Manager - Clg, !- Name Temperature, !- Control Variable 10, !- Minimum Supply Air Temperature {C} 50, !- Maximum Supply Air Temperature {C} Basement, !- Control Zone Name Basement Air Node, !- Zone Node Name Basement Direct Air Inlet Node Name, !- Zone Inlet Node Name Basement Inlet Nodes; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, DataCenter Basement SupAirTemp Manager - Clg, !- Name Temperature, !- Control Variable 10, !- Minimum Supply Air Temperature {C} 50, !- Maximum Supply Air Temperature {C} DataCenter_basement_ZN_6,!- Control Zone Name DataCenter Basement Zone Air Node, !- Zone Node Name DataCenter Basement Supply Inlet, !- Zone Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter Basement; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, DataCenter_bot_ZN_6 SupAirTemp Manager - Clg, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} DataCenter_bot_ZN_6, !- Control Zone Name DataCenter bot Zone Air Node, !- Zone Node Name DataCenter bot Supply Inlet, !- Zone Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter bot; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, DataCenter_mid_ZN_6 SupAirTemp Manager - Clg, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} DataCenter_mid_ZN_6, !- Control Zone Name DataCenter mid Zone Air Node, !- Zone Node Name DataCenter mid Supply Inlet, !- Zone Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter mid; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, DataCenter_top_ZN_6 SupAirTemp Manager - Clg, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} DataCenter_top_ZN_6, !- Control Zone Name DataCenter top Zone Air Node, !- Zone Node Name DataCenter top Supply Inlet, !- Zone Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter top; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: SET POINT MANAGER:WARMEST =========== SetpointManager:OutdoorAirReset, VAV_bot Supply Air Temperature Manager, !- Name Temperature, !- Control Variable 15.6, !- Setpoint at Outdoor Low Temperature {C} 10, !- Outdoor Low Temperature {C} 12.8, !- Setpoint at Outdoor High Temperature {C} 21.1, !- Outdoor High Temperature {C} VAV_bot WITH REHEAT Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:OutdoorAirReset, VAV_mid Supply Air Temperature Manager, !- Name Temperature, !- Control Variable 15.6, !- Setpoint at Outdoor Low Temperature {C} 10, !- Outdoor Low Temperature {C} 12.8, !- Setpoint at Outdoor High Temperature {C} 21.1, !- Outdoor High Temperature {C} VAV_mid WITH REHEAT Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:OutdoorAirReset, VAV_top Supply Air Temperature Manager, !- Name Temperature, !- Control Variable 15.6, !- Setpoint at Outdoor Low Temperature {C} 10, !- Outdoor Low Temperature {C} 12.8, !- Setpoint at Outdoor High Temperature {C} 21.1, !- Outdoor High Temperature {C} VAV_top WITH REHEAT Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:Scheduled, SHWSys1 Loop Setpoint Manager, !- Name Temperature, !- Control Variable SHWSys1-Loop-Temp-Schedule, !- Schedule Name SHWSys1 Supply Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:Scheduled, HeatSys1 Loop Setpoint Manager, !- Name Temperature, !- Control Variable HW-Loop-Temp-Schedule, !- Schedule Name HeatSys1 Supply Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:Scheduled, CoolSys1 Loop Setpoint Manager, !- Name Temperature, !- Control Variable CW-Loop-Temp-Schedule, !- Schedule Name CoolSys1 Supply Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:Scheduled, TowerWaterSystem Loop Setpoint Manager, !- Name Temperature, !- Control Variable Tower-Loop-Temp-Schedule,!- Schedule Name TowerWaterSys Supply Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:Scheduled, CoolSys1 Loop Plant Demand Inlet Setpoint Manager, !- Name Temperature, !- Control Variable CW-Loop-Temp-Schedule, !- Schedule Name CoolSys1 Demand Inlet Node; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:SCHEDULED:DUALSETPOINT =========== SetpointManager:Scheduled:DualSetpoint, Water Loop Setpoint Manager, !- Name Temperature, !- Control Variable PLANT LOOP HIGH TEMP SCHEDULE, !- High Setpoint Schedule Name PLANT LOOP LOW TEMP SCHEDULE, !- Low Setpoint Schedule Name Plant Supply Outlet Node;!- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:SINGLEZONE:HUMIDITY:MINIMUM =========== SetpointManager:SingleZone:Humidity:Minimum, DataCenter_Basement Humidifier HUMRAT setpoint, !- Name DataCenter_Humidifier-DataCenter_ExtraElecHeatCNode, !- Setpoint Node or NodeList Name DataCenter Basement Zone Air Node; !- Control Zone Air Node Name !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:MIXEDAIR =========== SetpointManager:MixedAir, DataCenter_ExtraElecHeatC Air Temp Manager, !- Name Temperature, !- Control Variable AirLoop DataCenter Basement Supply Air Outlet, !- Reference Setpoint Node Name DataCenter Basement Mixed Air Outlet, !- Fan Inlet Node Name AirLoop DataCenter Basement Supply Fan Outlet, !- Fan Outlet Node Name DataCenter_ExtraElecHeatC-DataCenter_ExtraWaterHeatCNode; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: SET POINT MANAGER:MIXED AIR =========== SetpointManager:MixedAir, CAV_bas_CoolC SAT Manager, !- Name Temperature, !- Control Variable Basement Inlet Nodes, !- Reference Setpoint Node Name CAV_bas_HeatC-CAV_FanNode, !- Fan Inlet Node Name CAV_bas Supply Equipment Outlet Node, !- Fan Outlet Node Name CAV_bas_CoolC-CAV_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, CAV_bas_HeatC SAT Manager, !- Name Temperature, !- Control Variable CAV_bas Supply Equipment Outlet Node, !- Reference Setpoint Node Name CAV_bas_HeatC-CAV_FanNode, !- Fan Inlet Node Name CAV_bas Supply Equipment Outlet Node, !- Fan Outlet Node Name CAV_bas_HeatC-CAV_FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, CAV_bas_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable Basement Inlet Nodes, !- Reference Setpoint Node Name CAV_bas_HeatC-CAV_FanNode, !- Fan Inlet Node Name CAV_bas Supply Equipment Outlet Node, !- Fan Outlet Node Name CAV_bas_OA-CAV_CoolCNode;!- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_bot WITH REHEAT_CoolC SAT Manager, !- Name Temperature, !- Control Variable VAV_bot WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_bot WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_bot WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_bot WITH REHEAT_HeatC SAT Manager, !- Name Temperature, !- Control Variable VAV_bot WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_bot WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_bot WITH REHEAT_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable VAV_bot WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_bot WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_mid WITH REHEAT_CoolC SAT Manager, !- Name Temperature, !- Control Variable VAV_mid WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_mid WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_mid WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_mid WITH REHEAT_HeatC SAT Manager, !- Name Temperature, !- Control Variable VAV_mid WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_mid WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_mid WITH REHEAT_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable VAV_mid WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_mid WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_top WITH REHEAT_CoolC SAT Manager, !- Name Temperature, !- Control Variable VAV_top WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_top WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_top WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_top WITH REHEAT_HeatC SAT Manager, !- Name Temperature, !- Control Variable VAV_top WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_top WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, VAV_top WITH REHEAT_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable VAV_top WITH REHEAT Supply Equipment Outlet Node, !- Reference Setpoint Node Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Fan Inlet Node Name VAV_top WITH REHEAT Supply Equipment Outlet Node, !- Fan Outlet Node Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, DataCenter Basement OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable Cooling Coil Air Outlet Node AirLoop DataCenter Basement, !- Reference Setpoint Node Name DataCenter Basement Mixed Air Outlet, !- Fan Inlet Node Name AirLoop DataCenter Basement Supply Fan Outlet, !- Fan Outlet Node Name DataCenter Basement Mixed Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, DataCenter bot OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable Cooling Coil Air Outlet Node AirLoop DataCenter bot, !- Reference Setpoint Node Name DataCenter bot Mixed Air Outlet, !- Fan Inlet Node Name AirLoop DataCenter bot Supply Fan Outlet, !- Fan Outlet Node Name DataCenter bot Mixed Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, DataCenter mid OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable Cooling Coil Air Outlet Node AirLoop DataCenter mid, !- Reference Setpoint Node Name DataCenter mid Mixed Air Outlet, !- Fan Inlet Node Name AirLoop DataCenter mid Supply Fan Outlet, !- Fan Outlet Node Name DataCenter mid Mixed Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, DataCenter top OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable Cooling Coil Air Outlet Node AirLoop DataCenter top, !- Reference Setpoint Node Name DataCenter top Mixed Air Outlet, !- Fan Inlet Node Name AirLoop DataCenter top Supply Fan Outlet, !- Fan Outlet Node Name DataCenter top Mixed Air Outlet; !- Setpoint Node or NodeList Name SetpointManager:OutdoorAirPretreat, VAV_bot WITH REHEAT Heat Exhchanger Supply Air Temp Manager, !- Name Temperature, !- Control Variable -99, !- Minimum Setpoint Temperature {C} 99, !- Maximum Setpoint Temperature {C} 0.00001, !- Minimum Setpoint Humidity Ratio {kgWater/kgDryAir} 1.0, !- Maximum Setpoint Humidity Ratio {kgWater/kgDryAir} VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Reference Setpoint Node Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Stream Node Name VAV_bot WITH REHEAT_OAInlet Node, !- Outdoor Air Stream Node Name VAV_bot WITH REHEAT Supply Equipment Inlet Node, !- Return Air Stream Node Name VAV_bot WITH REHEAT Heat Recovery Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:OutdoorAirPretreat, VAV_mid WITH REHEAT Heat Exhchanger Supply Air Temp Manager, !- Name Temperature, !- Control Variable -99, !- Minimum Setpoint Temperature {C} 99, !- Maximum Setpoint Temperature {C} 0.00001, !- Minimum Setpoint Humidity Ratio {kgWater/kgDryAir} 1.0, !- Maximum Setpoint Humidity Ratio {kgWater/kgDryAir} VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Reference Setpoint Node Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Stream Node Name VAV_mid WITH REHEAT_OAInlet Node, !- Outdoor Air Stream Node Name VAV_mid WITH REHEAT Supply Equipment Inlet Node, !- Return Air Stream Node Name VAV_mid WITH REHEAT Heat Recovery Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:OutdoorAirPretreat, VAV_top WITH REHEAT Heat Exhchanger Supply Air Temp Manager, !- Name Temperature, !- Control Variable -99, !- Minimum Setpoint Temperature {C} 99, !- Maximum Setpoint Temperature {C} 0.00001, !- Minimum Setpoint Humidity Ratio {kgWater/kgDryAir} 1.0, !- Maximum Setpoint Humidity Ratio {kgWater/kgDryAir} VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Reference Setpoint Node Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Stream Node Name VAV_top WITH REHEAT_OAInlet Node, !- Outdoor Air Stream Node Name VAV_top WITH REHEAT Supply Equipment Inlet Node, !- Return Air Stream Node Name VAV_top WITH REHEAT Heat Recovery Outlet Node; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: CONTROLLER:SIMPLE =========== Controller:WaterCoil, CAV_bas_CoolC_Controller,!- Name Temperature, !- Control Variable REVERSE, !- Action FLOW, !- Actuator Variable CAV_bas_CoolC-CAV_HeatCNode, !- Sensor Node Name CAV_bas_CoolCDemand Inlet Node, !- Actuator Node Name , !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, CAV_bas_HeatC_Controller,!- Name Temperature, !- Control Variable NORMAL, !- Action FLOW, !- Actuator Variable CAV_bas_HeatC-CAV_FanNode, !- Sensor Node Name CAV_bas_HeatCDemand Inlet Node, !- Actuator Node Name 0.0001, !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, VAV_bot WITH REHEAT_CoolC_Controller, !- Name Temperature, !- Control Variable REVERSE, !- Action FLOW, !- Actuator Variable VAV_bot WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Sensor Node Name VAV_bot WITH REHEAT_CoolCDemand Inlet Node, !- Actuator Node Name , !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, VAV_bot WITH REHEAT_HeatC_Controller, !- Name Temperature, !- Control Variable NORMAL, !- Action FLOW, !- Actuator Variable VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Sensor Node Name VAV_bot WITH REHEAT_HeatCDemand Inlet Node, !- Actuator Node Name 0.0001, !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, VAV_mid WITH REHEAT_CoolC_Controller, !- Name Temperature, !- Control Variable REVERSE, !- Action FLOW, !- Actuator Variable VAV_mid WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Sensor Node Name VAV_mid WITH REHEAT_CoolCDemand Inlet Node, !- Actuator Node Name , !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, VAV_mid WITH REHEAT_HeatC_Controller, !- Name Temperature, !- Control Variable NORMAL, !- Action FLOW, !- Actuator Variable VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Sensor Node Name VAV_mid WITH REHEAT_HeatCDemand Inlet Node, !- Actuator Node Name 0.0001, !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, VAV_top WITH REHEAT_CoolC_Controller, !- Name Temperature, !- Control Variable REVERSE, !- Action FLOW, !- Actuator Variable VAV_top WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Sensor Node Name VAV_top WITH REHEAT_CoolCDemand Inlet Node, !- Actuator Node Name , !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, VAV_top WITH REHEAT_HeatC_Controller, !- Name Temperature, !- Control Variable NORMAL, !- Action FLOW, !- Actuator Variable VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Sensor Node Name VAV_top WITH REHEAT_HeatCDemand Inlet Node, !- Actuator Node Name 0.0001, !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} Controller:WaterCoil, DataCenter_bas_HeatC_Controller, !- Name Temperature, !- Control Variable NORMAL, !- Action FLOW, !- Actuator Variable AirLoop DataCenter Basement Supply Air Outlet, !- Sensor Node Name DataCenter_ExtraWaterHeatCDemand Inlet Node, !- Actuator Node Name , !- Controller Convergence Tolerance {deltaC} AUTOSIZE, !- Maximum Actuated Flow {m3/s} 0.0; !- Minimum Actuated Flow {m3/s} !- =========== ALL OBJECTS IN CLASS: CONTROLLER:OUTSIDE AIR =========== Controller:OutdoorAir, CAV_bas_OA_Controller, !- Name CAV_bas_OARelief Node, !- Relief Air Outlet Node Name CAV_bas Supply Equipment Inlet Node, !- Return Air Node Name CAV_bas_OA-CAV_CoolCNode, !- Mixed Air Node Name CAV_bas_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} DifferentialDryBulb, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name , !- Mechanical Ventilation Controller Name , !- Time of Day Economizer Control Schedule Name , !- High Humidity Control , !- Humidistat Control Zone Name , !- High Humidity Outdoor Air Flow Ratio , !- Control High Indoor Humidity Based on Outdoor Humidity Ratio ; !- Heat Recovery Bypass Control Type!- Heat Recovery Bypass Control Type Controller:OutdoorAir, VAV_bot WITH REHEAT_OA_Controller, !- Name VAV_bot WITH REHEAT_OARelief Node, !- Relief Air Outlet Node Name VAV_bot WITH REHEAT Supply Equipment Inlet Node, !- Return Air Node Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Node Name VAV_bot WITH REHEAT_OAInlet Node, !- Actuator Node Name 0, !- Minimum Outdoor Air Flow Rate {m3/s} !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} DifferentialDryBulb, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name VAV_BOT WITH REHEAT Max OA Fraction, !- Maximum Fraction of Outdoor Air Schedule Name VAV_bot WITH REHEAT_DCV, !- Mechanical Ventilation Controller Name , !- Time of Day Economizer Control Schedule Name , !- High Humidity Control , !- Humidistat Control Zone Name , !- High Humidity Outdoor Air Flow Ratio , !- Control High Indoor Humidity Based on Outdoor Humidity Ratio BypassWhenOAFlowGreaterThanMinimum; !- Heat Recovery Bypass Control Type Controller:OutdoorAir, VAV_mid WITH REHEAT_OA_Controller, !- Name VAV_mid WITH REHEAT_OARelief Node, !- Relief Air Outlet Node Name VAV_mid WITH REHEAT Supply Equipment Inlet Node, !- Return Air Node Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Node Name VAV_mid WITH REHEAT_OAInlet Node, !- Actuator Node Name 0, !- Minimum Outdoor Air Flow Rate {m3/s} !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} DifferentialDryBulb, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name VAV_MID WITH REHEAT Max OA Fraction, !- Maximum Fraction of Outdoor Air Schedule Name VAV_mid WITH REHEAT_DCV, !- Mechanical Ventilation Controller Name , !- Time of Day Economizer Control Schedule Name , !- High Humidity Control , !- Humidistat Control Zone Name , !- High Humidity Outdoor Air Flow Ratio , !- Control High Indoor Humidity Based on Outdoor Humidity Ratio BypassWhenOAFlowGreaterThanMinimum; !- Heat Recovery Bypass Control Type Controller:OutdoorAir, VAV_top WITH REHEAT_OA_Controller, !- Name VAV_top WITH REHEAT_OARelief Node, !- Relief Air Outlet Node Name VAV_top WITH REHEAT Supply Equipment Inlet Node, !- Return Air Node Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Mixed Air Node Name VAV_top WITH REHEAT_OAInlet Node, !- Actuator Node Name 0, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} DifferentialDryBulb, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name VAV_TOP WITH REHEAT Max OA Fraction, !- Maximum Fraction of Outdoor Air Schedule Name VAV_top WITH REHEAT_DCV, !- Mechanical Ventilation Controller Name , !- Time of Day Economizer Control Schedule Name , !- High Humidity Control , !- Humidistat Control Zone Name , !- High Humidity Outdoor Air Flow Ratio , !- Control High Indoor Humidity Based on Outdoor Humidity Ratio BypassWhenOAFlowGreaterThanMinimum; !- Heat Recovery Bypass Control Type Controller:OutdoorAir, AirLoop DataCenter Basement OA Controller, !- Name DataCenter Basement Relief Air Outlet, !- Relief Air Outlet Node Name AirLoop DataCenter Basement Return Air Inlet, !- Return Air Node Name DataCenter Basement Mixed Air Outlet, !- Mixed Air Node Name DataCenter Basement Outside Air Inlet, !- Actuator Node Name autosize, !- Minimum Outdoor Air Flow Rate {m3/s} autosize, !- Maximum Outdoor Air Flow Rate {m3/s} DifferentialDryBulb, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, AirLoop DataCenter bot OA Controller, !- Name DataCenter bot Relief Air Outlet, !- Relief Air Outlet Node Name AirLoop DataCenter bot Return Air Inlet, !- Return Air Node Name DataCenter bot Mixed Air Outlet, !- Mixed Air Node Name DataCenter bot Outside Air Inlet, !- Actuator Node Name 0, !- Minimum Outdoor Air Flow Rate {m3/s} autosize, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, AirLoop DataCenter mid OA Controller, !- Name DataCenter mid Relief Air Outlet, !- Relief Air Outlet Node Name AirLoop DataCenter mid Return Air Inlet, !- Return Air Node Name DataCenter mid Mixed Air Outlet, !- Mixed Air Node Name DataCenter mid Outside Air Inlet, !- Actuator Node Name 0, !- Minimum Outdoor Air Flow Rate {m3/s} autosize, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, AirLoop DataCenter top OA Controller, !- Name DataCenter top Relief Air Outlet, !- Relief Air Outlet Node Name AirLoop DataCenter top Return Air Inlet, !- Return Air Node Name DataCenter top Mixed Air Outlet, !- Mixed Air Node Name DataCenter top Outside Air Inlet, !- Actuator Node Name 0, !- Minimum Outdoor Air Flow Rate {m3/s} autosize, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type , !- Economizer Maximum Limit Dry-Bulb Temperature {C} !- Economizer Maximum Limit Dry-Bulb Temperature {C} , !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name , !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name !- =========== ALL OBJECTS IN CLASS: CONTROLLER:MECHANICALVENTILATION =========== Controller:MechanicalVentilation, VAV_top WITH REHEAT_DCV, !- Name MinOA_MotorizedDamper_Sched, !- Availability Schedule Name Yes, !- Demand Controlled Ventilation VentilationRateProcedure,!- System Outdoor Air Method , !- Zone Maximum Outdoor Air Fraction {dimensionless} Core_top, !- Zone 1 Name CM DSOA Core_top, !- Design Specification Outdoor Air Object Name 1 CM DSZAD Core_top, !- Design Specification Zone Air Distribution Object Name 1 Perimeter_top_ZN_1, !- Zone 2 Name CM DSOA Perimeter_top_ZN_1, !- Design Specification Outdoor Air Object Name 2 CM DSZAD Perimeter_top_ZN_1, !- Design Specification Zone Air Distribution Object Name 2 Perimeter_top_ZN_2, !- Zone 3 Name CM DSOA Perimeter_top_ZN_2, !- Design Specification Outdoor Air Object Name 3 CM DSZAD Perimeter_top_ZN_2, !- Design Specification Zone Air Distribution Object Name 3 Perimeter_top_ZN_3, !- Zone 4 Name CM DSOA Perimeter_top_ZN_3, !- Design Specification Outdoor Air Object Name 4 CM DSZAD Perimeter_top_ZN_3, !- Design Specification Zone Air Distribution Object Name 4 Perimeter_top_ZN_4, !- Zone 5 Name CM DSOA Perimeter_top_ZN_4, !- Design Specification Outdoor Air Object Name 5 CM DSZAD Perimeter_top_ZN_4; !- Design Specification Zone Air Distribution Object Name 5 DesignSpecification:ZoneAirDistribution, CM DSZAD Core_top, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_top_ZN_1, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_top_ZN_2, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_top_ZN_3, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_top_ZN_4, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:OutdoorAir, CM DSOA Core_top, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_top_ZN_1, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_top_ZN_2, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_top_ZN_3, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_top_ZN_4, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} Controller:MechanicalVentilation, VAV_bot WITH REHEAT_DCV, !- Name MinOA_MotorizedDamper_Sched, !- Availability Schedule Name Yes, !- Demand Controlled Ventilation VentilationRateProcedure,!- System Outdoor Air Method , !- Zone Maximum Outdoor Air Fraction {dimensionless} Core_bottom, !- Zone 1 Name CM DSOA Core_bottom, !- Design Specification Outdoor Air Object Name 1 CM DSZAD Core_bottom, !- Design Specification Zone Air Distribution Object Name 1 Perimeter_bot_ZN_1, !- Zone 2 Name CM DSOA Perimeter_bot_ZN_1, !- Design Specification Outdoor Air Object Name 2 CM DSZAD Perimeter_bot_ZN_1, !- Design Specification Zone Air Distribution Object Name 2 Perimeter_bot_ZN_2, !- Zone 3 Name CM DSOA Perimeter_bot_ZN_2, !- Design Specification Outdoor Air Object Name 3 CM DSZAD Perimeter_bot_ZN_2, !- Design Specification Zone Air Distribution Object Name 3 Perimeter_bot_ZN_3, !- Zone 4 Name CM DSOA Perimeter_bot_ZN_3, !- Design Specification Outdoor Air Object Name 4 CM DSZAD Perimeter_bot_ZN_3, !- Design Specification Zone Air Distribution Object Name 4 Perimeter_bot_ZN_4, !- Zone 5 Name CM DSOA Perimeter_bot_ZN_4, !- Design Specification Outdoor Air Object Name 5 CM DSZAD Perimeter_bot_ZN_4; !- Design Specification Zone Air Distribution Object Name 5 DesignSpecification:ZoneAirDistribution, CM DSZAD Core_bottom, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_bot_ZN_1, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_bot_ZN_2, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_bot_ZN_3, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_bot_ZN_4, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:OutdoorAir, CM DSOA Core_bottom, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_bot_ZN_1, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_bot_ZN_2, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_bot_ZN_3, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_bot_ZN_4, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} Controller:MechanicalVentilation, VAV_mid WITH REHEAT_DCV, !- Name MinOA_MotorizedDamper_Sched, !- Availability Schedule Name Yes, !- Demand Controlled Ventilation VentilationRateProcedure,!- System Outdoor Air Method , !- Zone Maximum Outdoor Air Fraction {dimensionless} Core_mid, !- Zone 1 Name CM DSOA Core_mid, !- Design Specification Outdoor Air Object Name 1 CM DSZAD Core_mid, !- Design Specification Zone Air Distribution Object Name 1 Perimeter_mid_ZN_1, !- Zone 2 Name CM DSOA Perimeter_mid_ZN_1, !- Design Specification Outdoor Air Object Name 2 CM DSZAD Perimeter_mid_ZN_1, !- Design Specification Zone Air Distribution Object Name 2 Perimeter_mid_ZN_2, !- Zone 3 Name CM DSOA Perimeter_mid_ZN_2, !- Design Specification Outdoor Air Object Name 3 CM DSZAD Perimeter_mid_ZN_2, !- Design Specification Zone Air Distribution Object Name 3 Perimeter_mid_ZN_3, !- Zone 4 Name CM DSOA Perimeter_mid_ZN_3, !- Design Specification Outdoor Air Object Name 4 CM DSZAD Perimeter_mid_ZN_3, !- Design Specification Zone Air Distribution Object Name 4 Perimeter_mid_ZN_4, !- Zone 5 Name CM DSOA Perimeter_mid_ZN_4, !- Design Specification Outdoor Air Object Name 5 CM DSZAD Perimeter_mid_ZN_4; !- Design Specification Zone Air Distribution Object Name 5 DesignSpecification:ZoneAirDistribution, CM DSZAD Core_mid, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_mid_ZN_1, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_mid_ZN_2, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_mid_ZN_3, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:ZoneAirDistribution, CM DSZAD Perimeter_mid_ZN_4, !- Name 1, !- Zone Air Distribution Effectiveness in Cooling Mode {dimensionless} 1, !- Zone Air Distribution Effectiveness in Heating Mode {dimensionless} ; !- Zone Air Distribution Effectiveness Schedule Name DesignSpecification:OutdoorAir, CM DSOA Core_mid, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_mid_ZN_1, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_mid_ZN_2, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_mid_ZN_3, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} DesignSpecification:OutdoorAir, CM DSOA Perimeter_mid_ZN_4, !- Name Sum, !- Outdoor Air Method 0.00000001, !- Outdoor Air Flow per Person {m3/s-person} 0.000431773; !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} !- =========== ALL OBJECTS IN CLASS: CONTROLLED ZONE EQUIP CONFIGURATION =========== ZoneHVAC:EquipmentConnections, Basement, !- Zone Name Basement Equipment, !- Zone Conditioning Equipment List Name Basement Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Basement Air Node, !- Zone Air Node Name Basement Return Air Node;!- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Core_bottom, !- Zone Name Core_bottom Equipment, !- Zone Conditioning Equipment List Name Core_bottom Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Core_bottom Air Node, !- Zone Air Node Name Core_bottom Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Core_mid, !- Zone Name Core_mid Equipment, !- Zone Conditioning Equipment List Name Core_mid Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Core_mid Air Node, !- Zone Air Node Name Core_mid Return Air Node;!- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Core_top, !- Zone Name Core_top Equipment, !- Zone Conditioning Equipment List Name Core_top Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Core_top Air Node, !- Zone Air Node Name Core_top Return Air Node;!- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_bot_ZN_3, !- Zone Name Perimeter_bot_ZN_3 Equipment, !- Zone Conditioning Equipment List Name Perimeter_bot_ZN_3 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_bot_ZN_3 Air Node, !- Zone Air Node Name Perimeter_bot_ZN_3 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_bot_ZN_2, !- Zone Name Perimeter_bot_ZN_2 Equipment, !- Zone Conditioning Equipment List Name Perimeter_bot_ZN_2 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_bot_ZN_2 Air Node, !- Zone Air Node Name Perimeter_bot_ZN_2 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_bot_ZN_1, !- Zone Name Perimeter_bot_ZN_1 Equipment, !- Zone Conditioning Equipment List Name Perimeter_bot_ZN_1 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_bot_ZN_1 Air Node, !- Zone Air Node Name Perimeter_bot_ZN_1 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_bot_ZN_4, !- Zone Name Perimeter_bot_ZN_4 Equipment, !- Zone Conditioning Equipment List Name Perimeter_bot_ZN_4 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_bot_ZN_4 Air Node, !- Zone Air Node Name Perimeter_bot_ZN_4 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_mid_ZN_3, !- Zone Name Perimeter_mid_ZN_3 Equipment, !- Zone Conditioning Equipment List Name Perimeter_mid_ZN_3 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_mid_ZN_3 Air Node, !- Zone Air Node Name Perimeter_mid_ZN_3 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_mid_ZN_2, !- Zone Name Perimeter_mid_ZN_2 Equipment, !- Zone Conditioning Equipment List Name Perimeter_mid_ZN_2 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_mid_ZN_2 Air Node, !- Zone Air Node Name Perimeter_mid_ZN_2 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_mid_ZN_1, !- Zone Name Perimeter_mid_ZN_1 Equipment, !- Zone Conditioning Equipment List Name Perimeter_mid_ZN_1 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_mid_ZN_1 Air Node, !- Zone Air Node Name Perimeter_mid_ZN_1 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_mid_ZN_4, !- Zone Name Perimeter_mid_ZN_4 Equipment, !- Zone Conditioning Equipment List Name Perimeter_mid_ZN_4 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_mid_ZN_4 Air Node, !- Zone Air Node Name Perimeter_mid_ZN_4 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_top_ZN_3, !- Zone Name Perimeter_top_ZN_3 Equipment, !- Zone Conditioning Equipment List Name Perimeter_top_ZN_3 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_top_ZN_3 Air Node, !- Zone Air Node Name Perimeter_top_ZN_3 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_top_ZN_2, !- Zone Name Perimeter_top_ZN_2 Equipment, !- Zone Conditioning Equipment List Name Perimeter_top_ZN_2 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_top_ZN_2 Air Node, !- Zone Air Node Name Perimeter_top_ZN_2 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_top_ZN_1, !- Zone Name Perimeter_top_ZN_1 Equipment, !- Zone Conditioning Equipment List Name Perimeter_top_ZN_1 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_top_ZN_1 Air Node, !- Zone Air Node Name Perimeter_top_ZN_1 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_top_ZN_4, !- Zone Name Perimeter_top_ZN_4 Equipment, !- Zone Conditioning Equipment List Name Perimeter_top_ZN_4 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_top_ZN_4 Air Node, !- Zone Air Node Name Perimeter_top_ZN_4 Return Air Node; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, DataCenter_basement_ZN_6,!- Zone Name DataCenter Basement Equipment, !- Zone Conditioning Equipment List Name DataCenter Basement Inlets, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name DataCenter Basement Zone Air Node, !- Zone Air Node Name DataCenter Basement Return Outlet; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, DataCenter_bot_ZN_6, !- Zone Name DataCenter bot Equipment,!- Zone Conditioning Equipment List Name DataCenter bot Inlets, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name DataCenter bot Zone Air Node, !- Zone Air Node Name DataCenter bot Return Outlet; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, DataCenter_mid_ZN_6, !- Zone Name DataCenter mid Equipment,!- Zone Conditioning Equipment List Name DataCenter mid Inlets, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name DataCenter mid Zone Air Node, !- Zone Air Node Name DataCenter mid Return Outlet; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, DataCenter_top_ZN_6, !- Zone Name DataCenter top Equipment,!- Zone Conditioning Equipment List Name DataCenter top Inlets, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name DataCenter top Zone Air Node, !- Zone Air Node Name DataCenter top Return Outlet; !- Zone Return Air Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: ZONE EQUIPMENT LIST =========== ZoneHVAC:EquipmentList, Basement Equipment, !- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type Basement Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Core_bottom Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Core_bottom VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Core_mid Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Core_mid VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Core_top Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Core_top VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_bot_ZN_3 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_bot_ZN_3 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_bot_ZN_2 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_bot_ZN_2 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_bot_ZN_1 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_bot_ZN_1 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_bot_ZN_4 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_bot_ZN_4 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_mid_ZN_3 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_mid_ZN_3 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_mid_ZN_2 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_mid_ZN_2 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_mid_ZN_1 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_mid_ZN_1 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_mid_ZN_4 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_mid_ZN_4 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_top_ZN_3 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_top_ZN_3 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_top_ZN_2 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_top_ZN_2 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_top_ZN_1 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_top_ZN_1 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_top_ZN_4 Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Perimeter_top_ZN_4 VAV Box, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, DataCenter Basement Equipment, !- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type DataCenter Basement Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, DataCenter bot Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type DataCenter bot Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, DataCenter mid Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type DataCenter mid Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, DataCenter top Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type DataCenter top Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence !- =========== ALL OBJECTS IN CLASS: AIR DISTRIBUTION UNIT =========== ZoneHVAC:AirDistributionUnit, Core_bottom VAV Box, !- Name Core_bottom VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Core_bottom VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Core_mid VAV Box, !- Name Core_mid VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Core_mid VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Core_top VAV Box, !- Name Core_top VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Core_top VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_bot_ZN_3 VAV Box, !- Name Perimeter_bot_ZN_3 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_bot_ZN_3 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_bot_ZN_2 VAV Box, !- Name Perimeter_bot_ZN_2 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_bot_ZN_2 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_bot_ZN_1 VAV Box, !- Name Perimeter_bot_ZN_1 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_bot_ZN_1 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_bot_ZN_4 VAV Box, !- Name Perimeter_bot_ZN_4 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_bot_ZN_4 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_mid_ZN_3 VAV Box, !- Name Perimeter_mid_ZN_3 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_mid_ZN_3 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_mid_ZN_2 VAV Box, !- Name Perimeter_mid_ZN_2 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_mid_ZN_2 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_mid_ZN_1 VAV Box, !- Name Perimeter_mid_ZN_1 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_mid_ZN_1 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_mid_ZN_4 VAV Box, !- Name Perimeter_mid_ZN_4 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_mid_ZN_4 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_top_ZN_3 VAV Box, !- Name Perimeter_top_ZN_3 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_top_ZN_3 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_top_ZN_2 VAV Box, !- Name Perimeter_top_ZN_2 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_top_ZN_2 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_top_ZN_1 VAV Box, !- Name Perimeter_top_ZN_1 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_top_ZN_1 VAV Box Component; !- Air Terminal Name ZoneHVAC:AirDistributionUnit, Perimeter_top_ZN_4 VAV Box, !- Name Perimeter_top_ZN_4 VAV Box Outlet Node, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:VAV:Reheat, !- Air Terminal Object Type Perimeter_top_ZN_4 VAV Box Component; !- Air Terminal Name !- =========== ALL OBJECTS IN CLASS: AIRTERMINAL:SINGLEDUCT:UNCONTROLLED =========== AirTerminal:SingleDuct:Uncontrolled, Basement Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Basement Direct Air Inlet Node Name, !- Zone Supply Air Node Name AUTOSIZE; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, DataCenter Basement Direct Air, !- Name Always_On, !- Availability Schedule Name DataCenter Basement Supply Inlet, !- Zone Supply Air Node Name autosize; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, DataCenter bot Direct Air, !- Name Always_On, !- Availability Schedule Name DataCenter bot Supply Inlet, !- Zone Supply Air Node Name autosize; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, DataCenter mid Direct Air, !- Name Always_On, !- Availability Schedule Name DataCenter mid Supply Inlet, !- Zone Supply Air Node Name autosize; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, DataCenter top Direct Air, !- Name Always_On, !- Availability Schedule Name DataCenter top Supply Inlet, !- Zone Supply Air Node Name autosize; !- Maximum Air Flow Rate {m3/s} !- =========== ALL OBJECTS IN CLASS: AIRTERMINAL:SINGLEDUCT:VAV:REHEAT =========== AirTerminal:SingleDuct:VAV:Reheat, Core_bottom VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Core_bottom VAV Box Damper Node, !- Damper Air Outlet Node Name Core_bottom VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.287, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Core_bottom VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Core_bottom VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Core_mid VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Core_mid VAV Box Damper Node, !- Damper Air Outlet Node Name Core_mid VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.307, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Core_mid VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Core_mid VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Core_top VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Core_top VAV Box Damper Node, !- Damper Air Outlet Node Name Core_top VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.307, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Core_top VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Core_top VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_bot_ZN_3 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_bot_ZN_3 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_bot_ZN_3 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.242, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_bot_ZN_3 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_bot_ZN_3 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_bot_ZN_2 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_bot_ZN_2 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_bot_ZN_2 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.103, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_bot_ZN_2 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_bot_ZN_2 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_bot_ZN_1 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_bot_ZN_1 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_bot_ZN_1 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.193, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_bot_ZN_1 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_bot_ZN_1 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_bot_ZN_4 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_bot_ZN_4 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_bot_ZN_4 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.085, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_bot_ZN_4 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_bot_ZN_4 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_mid_ZN_3 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_mid_ZN_3 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_mid_ZN_3 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.266, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_mid_ZN_3 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_mid_ZN_3 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_mid_ZN_2 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_mid_ZN_2 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_mid_ZN_2 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Scheduled, !- Zone Minimum Air Flow Input Method , !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} PERIMETER_MID_ZN_2_MDP_Sch, !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_mid_ZN_2 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_mid_ZN_2 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_mid_ZN_1 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_mid_ZN_1 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_mid_ZN_1 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.198, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_mid_ZN_1 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_mid_ZN_1 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_mid_ZN_4 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_mid_ZN_4 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_mid_ZN_4 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.093, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_mid_ZN_4 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_mid_ZN_4 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_top_ZN_3 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_top_ZN_3 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_top_ZN_3 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.23, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_top_ZN_3 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_top_ZN_3 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_top_ZN_2 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_top_ZN_2 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_top_ZN_2 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.097, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_top_ZN_2 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_top_ZN_2 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_top_ZN_1 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_top_ZN_1 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_top_ZN_1 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.179, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_top_ZN_1 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_top_ZN_1 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} AirTerminal:SingleDuct:VAV:Reheat, Perimeter_top_ZN_4 VAV Box Component, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_top_ZN_4 VAV Box Damper Node, !- Damper Air Outlet Node Name Perimeter_top_ZN_4 VAV Box Inlet Node, !- Air Inlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} Constant, !- Zone Minimum Air Flow Input Method 0.088, !- Constant Minimum Air Flow Fraction , !- Fixed Minimum Air Flow Rate {m3/s} , !- Minimum Air Flow Fraction Schedule Name Coil:Heating:Water, !- Reheat Coil Object Type Perimeter_top_ZN_4 VAV Box Reheat Coil, !- Reheat Coil Name AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} Perimeter_top_ZN_4 VAV Box Outlet Node, !- Air Outlet Node Name 0.001, !- Convergence Tolerance ReverseWithLimits, !- Damper Heating Action , !- Maximum Flow per Zone Floor Area During Reheat {m3/s-m2} 0.5, !- Maximum Flow Fraction During Reheat 40; !- Maximum Reheat Air Temperature {C} !- =========== ALL OBJECTS IN CLASS: ZONECONTROL:HUMIDISTAT =========== ZoneControl:Humidistat, DataCenter Basement Humidistat, !- Name DataCenter_basement_ZN_6,!- Zone Name DC_MinRelHumSetSch; !- Humidifying Relative Humidity Setpoint Schedule Name !- =========== ALL OBJECTS IN CLASS: ZONE CONTROL:THERMOSTATIC =========== ZoneControl:Thermostat, Basement Thermostat, !- Name Basement, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Basement DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Core_bottom Thermostat, !- Name Core_bottom, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Core_bottom DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Core_mid Thermostat, !- Name Core_mid, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Core_mid DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Core_top Thermostat, !- Name Core_top, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Core_top DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_bot_ZN_3 Thermostat, !- Name Perimeter_bot_ZN_3, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_bot_ZN_3 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_bot_ZN_2 Thermostat, !- Name Perimeter_bot_ZN_2, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_bot_ZN_2 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_bot_ZN_1 Thermostat, !- Name Perimeter_bot_ZN_1, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_bot_ZN_1 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_bot_ZN_4 Thermostat, !- Name Perimeter_bot_ZN_4, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_bot_ZN_4 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_mid_ZN_3 Thermostat, !- Name Perimeter_mid_ZN_3, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_mid_ZN_3 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_mid_ZN_2 Thermostat, !- Name Perimeter_mid_ZN_2, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_mid_ZN_2 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_mid_ZN_1 Thermostat, !- Name Perimeter_mid_ZN_1, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_mid_ZN_1 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_mid_ZN_4 Thermostat, !- Name Perimeter_mid_ZN_4, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_mid_ZN_4 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_top_ZN_3 Thermostat, !- Name Perimeter_top_ZN_3, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_top_ZN_3 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_top_ZN_2 Thermostat, !- Name Perimeter_top_ZN_2, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_top_ZN_2 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_top_ZN_1 Thermostat, !- Name Perimeter_top_ZN_1, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_top_ZN_1 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_top_ZN_4 Thermostat, !- Name Perimeter_top_ZN_4, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_top_ZN_4 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, DataCenter Basement Thermostat, !- Name DataCenter_basement_ZN_6,!- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type DataCenter Cooling Setpoints Dual SP Control; !- Control 1 Name ZoneControl:Thermostat, DataCenter bot Thermostat, !- Name DataCenter_bot_ZN_6, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type DataCenter Cooling Setpoints Dual SP Control; !- Control 1 Name ZoneControl:Thermostat, DataCenter mid Thermostat, !- Name DataCenter_mid_ZN_6, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type DataCenter Cooling Setpoints Dual SP Control; !- Control 1 Name ZoneControl:Thermostat, DataCenter top Thermostat, !- Name DataCenter_top_ZN_6, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type DataCenter Cooling Setpoints Dual SP Control; !- Control 1 Name !- =========== ALL OBJECTS IN CLASS: DUAL SETPOINT WITH DEADBAND =========== ThermostatSetpoint:DualSetpoint, Basement DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Core_bottom DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Core_mid DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Core_top DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_bot_ZN_3 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_bot_ZN_2 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_bot_ZN_1 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_bot_ZN_4 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_mid_ZN_3 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_mid_ZN_2 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM_w_SB, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM_w_SB; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_mid_ZN_1 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_mid_ZN_4 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_top_ZN_3 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_top_ZN_2 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_top_ZN_1 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_top_ZN_4 DualSPSched, !- Name HTGSETP_SCH_YES_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_YES_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, DataCenter Cooling Setpoints Dual SP Control, !- Name HTGSETP_DC_SCH, !- Heating Setpoint Temperature Schedule Name CLGSETP_DC_SCH; !- Cooling Setpoint Temperature Schedule Name !- =========== ALL OBJECTS IN CLASS: ZONE SUPPLY AIR PATH =========== AirLoopHVAC:SupplyPath, CAV_bas, !- Name CAV_bas Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type CAV_bas Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, VAV_bot WITH REHEAT, !- Name VAV_bot WITH REHEAT Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type VAV_bot WITH REHEAT Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, VAV_mid WITH REHEAT, !- Name VAV_mid WITH REHEAT Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type VAV_mid WITH REHEAT Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, VAV_top WITH REHEAT, !- Name VAV_top WITH REHEAT Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type VAV_top WITH REHEAT Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, AirLoop DataCenter Basement Supply Path, !- Name ZoneSplitter DataCenter Basement Supply Air Inlet, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type AirLoop DataCenter Basement Zone Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, AirLoop DataCenter bot Supply Path, !- Name ZoneSplitter DataCenter bot Supply Air Inlet, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type AirLoop DataCenter bot Zone Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, AirLoop DataCenter mid Supply Path, !- Name ZoneSplitter DataCenter mid Supply Air Inlet, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type AirLoop DataCenter mid Zone Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, AirLoop DataCenter top Supply Path, !- Name ZoneSplitter DataCenter top Supply Air Inlet, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type AirLoop DataCenter top Zone Splitter; !- Component 1 Name !- =========== ALL OBJECTS IN CLASS: ZONE RETURN AIR PATH =========== AirLoopHVAC:ReturnPath, CAV_bas Return Air Path, !- Name CAV_bas Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type CAV_bas Return Air Mixer;!- Component 1 Name AirLoopHVAC:ReturnPath, VAV_bot WITH REHEAT Return Air Path, !- Name VAV_bot WITH REHEAT Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ReturnPlenum,!- Component 1 Object Type GroundFloor_Return_Plenum, !- Component 1 Name AirLoopHVAC:ZoneMixer, !- Component 2 Object Type VAV_bot WITH REHEAT Return Air Mixer; !- Component 2 Name AirLoopHVAC:ReturnPath, VAV_mid WITH REHEAT Return Air Path, !- Name VAV_mid WITH REHEAT Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ReturnPlenum,!- Component 1 Object Type MidFloor_Return_Plenum, !- Component 1 Name AirLoopHVAC:ZoneMixer, !- Component 2 Object Type VAV_mid WITH REHEAT Return Air Mixer; !- Component 2 Name AirLoopHVAC:ReturnPath, VAV_top WITH REHEAT Return Air Path, !- Name VAV_top WITH REHEAT Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ReturnPlenum,!- Component 1 Object Type TopFloor_Return_Plenum, !- Component 1 Name AirLoopHVAC:ZoneMixer, !- Component 2 Object Type VAV_top WITH REHEAT Return Air Mixer; !- Component 2 Name AirLoopHVAC:ReturnPath, AirLoop DataCenter Basement Return Path, !- Name ZoneMixer DataCenter Basement Return Air Outlet, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type AirLoop DataCenter Basement Zone Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, AirLoop DataCenter bot Return Path, !- Name ZoneMixer DataCenter bot Return Air Outlet, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type AirLoop DataCenter bot Zone Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, AirLoop DataCenter mid Return Path, !- Name ZoneMixer DataCenter mid Return Air Outlet, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type AirLoop DataCenter mid Zone Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, AirLoop DataCenter top Return Path, !- Name ZoneMixer DataCenter top Return Air Outlet, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type AirLoop DataCenter top Zone Mixer; !- Component 1 Name !- =========== ALL OBJECTS IN CLASS: ZONE RETURN PLENUM =========== AirLoopHVAC:ReturnPlenum, GroundFloor_Return_Plenum, !- Name GroundFloor_Plenum, !- Zone Name GroundFloor_Plenum Node, !- Zone Node Name GroundFloor_Plenum Outlet Node, !- Outlet Node Name , !- Induced Air Outlet Node or NodeList Name Perimeter_bot_ZN_1 Return Air Node, !- Inlet 1 Node Name Perimeter_bot_ZN_2 Return Air Node, !- Inlet 2 Node Name Perimeter_bot_ZN_3 Return Air Node, !- Inlet 3 Node Name Perimeter_bot_ZN_4 Return Air Node, !- Inlet 4 Node Name Core_bottom Return Air Node; !- Inlet 5 Node Name AirLoopHVAC:ReturnPlenum, MidFloor_Return_Plenum, !- Name MidFloor_Plenum, !- Zone Name MidFloor_Plenum Node, !- Zone Node Name MidFloor_Plenum Outlet Node, !- Outlet Node Name , !- Induced Air Outlet Node or NodeList Name Perimeter_mid_ZN_1 Return Air Node, !- Inlet 1 Node Name Perimeter_mid_ZN_2 Return Air Node, !- Inlet 2 Node Name Perimeter_mid_ZN_3 Return Air Node, !- Inlet 3 Node Name Perimeter_mid_ZN_4 Return Air Node, !- Inlet 4 Node Name Core_mid Return Air Node;!- Inlet 5 Node Name AirLoopHVAC:ReturnPlenum, TopFloor_Return_Plenum, !- Name TopFloor_Plenum, !- Zone Name TopFloor_Plenum Node, !- Zone Node Name TopFloor_Plenum Outlet Node, !- Outlet Node Name , !- Induced Air Outlet Node or NodeList Name Perimeter_top_ZN_1 Return Air Node, !- Inlet 1 Node Name Perimeter_top_ZN_2 Return Air Node, !- Inlet 2 Node Name Perimeter_top_ZN_3 Return Air Node, !- Inlet 3 Node Name Perimeter_top_ZN_4 Return Air Node, !- Inlet 4 Node Name Core_top Return Air Node;!- Inlet 5 Node Name !- =========== ALL OBJECTS IN CLASS: ZONE SPLITTER =========== AirLoopHVAC:ZoneSplitter, CAV_bas Supply Air Splitter, !- Name CAV_bas Zone Equipment Inlet Node, !- Inlet Node Name Basement Direct Air Inlet Node Name; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, VAV_bot WITH REHEAT Supply Air Splitter, !- Name VAV_bot WITH REHEAT Zone Equipment Inlet Node, !- Inlet Node Name Core_bottom VAV Box Inlet Node, !- Outlet 1 Node Name Perimeter_bot_ZN_3 VAV Box Inlet Node, !- Outlet 2 Node Name Perimeter_bot_ZN_2 VAV Box Inlet Node, !- Outlet 3 Node Name Perimeter_bot_ZN_1 VAV Box Inlet Node, !- Outlet 4 Node Name Perimeter_bot_ZN_4 VAV Box Inlet Node; !- Outlet 5 Node Name AirLoopHVAC:ZoneSplitter, VAV_mid WITH REHEAT Supply Air Splitter, !- Name VAV_mid WITH REHEAT Zone Equipment Inlet Node, !- Inlet Node Name Core_mid VAV Box Inlet Node, !- Outlet 1 Node Name Perimeter_mid_ZN_3 VAV Box Inlet Node, !- Outlet 2 Node Name Perimeter_mid_ZN_2 VAV Box Inlet Node, !- Outlet 3 Node Name Perimeter_mid_ZN_1 VAV Box Inlet Node, !- Outlet 4 Node Name Perimeter_mid_ZN_4 VAV Box Inlet Node; !- Outlet 5 Node Name AirLoopHVAC:ZoneSplitter, VAV_top WITH REHEAT Supply Air Splitter, !- Name VAV_top WITH REHEAT Zone Equipment Inlet Node, !- Inlet Node Name Core_top VAV Box Inlet Node, !- Outlet 1 Node Name Perimeter_top_ZN_3 VAV Box Inlet Node, !- Outlet 2 Node Name Perimeter_top_ZN_2 VAV Box Inlet Node, !- Outlet 3 Node Name Perimeter_top_ZN_1 VAV Box Inlet Node, !- Outlet 4 Node Name Perimeter_top_ZN_4 VAV Box Inlet Node; !- Outlet 5 Node Name AirLoopHVAC:ZoneSplitter, AirLoop DataCenter Basement Zone Splitter, !- Name ZoneSplitter DataCenter Basement Supply Air Inlet, !- Inlet Node Name DataCenter Basement Supply Inlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, AirLoop DataCenter bot Zone Splitter, !- Name ZoneSplitter DataCenter bot Supply Air Inlet, !- Inlet Node Name DataCenter bot Supply Inlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, AirLoop DataCenter mid Zone Splitter, !- Name ZoneSplitter DataCenter mid Supply Air Inlet, !- Inlet Node Name DataCenter mid Supply Inlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, AirLoop DataCenter top Zone Splitter, !- Name ZoneSplitter DataCenter top Supply Air Inlet, !- Inlet Node Name DataCenter top Supply Inlet; !- Outlet 1 Node Name !- =========== ALL OBJECTS IN CLASS: ZONE MIXER =========== AirLoopHVAC:ZoneMixer, CAV_bas Return Air Mixer,!- Name CAV_bas Zone Equipment Outlet Node, !- Outlet Node Name Basement Return Air Node;!- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, VAV_bot WITH REHEAT Return Air Mixer, !- Name VAV_bot WITH REHEAT Zone Equipment Outlet Node, !- Outlet Node Name GroundFloor_Plenum Outlet Node; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, VAV_mid WITH REHEAT Return Air Mixer, !- Name VAV_mid WITH REHEAT Zone Equipment Outlet Node, !- Outlet Node Name MidFloor_Plenum Outlet Node; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, VAV_top WITH REHEAT Return Air Mixer, !- Name VAV_top WITH REHEAT Zone Equipment Outlet Node, !- Outlet Node Name TopFloor_Plenum Outlet Node; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, AirLoop DataCenter Basement Zone Mixer, !- Name ZoneMixer DataCenter Basement Return Air Outlet, !- Outlet Node Name DataCenter Basement Return Outlet; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, AirLoop DataCenter bot Zone Mixer, !- Name ZoneMixer DataCenter bot Return Air Outlet, !- Outlet Node Name DataCenter bot Return Outlet; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, AirLoop DataCenter mid Zone Mixer, !- Name ZoneMixer DataCenter mid Return Air Outlet, !- Outlet Node Name DataCenter mid Return Outlet; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, AirLoop DataCenter top Zone Mixer, !- Name ZoneMixer DataCenter top Return Air Outlet, !- Outlet Node Name DataCenter top Return Outlet; !- Inlet 1 Node Name !- =========== ALL OBJECTS IN CLASS: BOILER:SIMPLE =========== Boiler:HotWater, HeatSys1 Boiler, !- Name NATURALGAS, !- Fuel Type 1953430.325, !- Nominal Capacity {W} 0.8125, !- Nominal Thermal Efficiency LeavingBoiler, !- Efficiency Curve Temperature Evaluation Variable HeatSys1 Boiler Efficiency Curve, !- Normalized Boiler Efficiency Curve Name AUTOSIZE, !- Design Water Flow Rate {m3/s} 0.0, !- Minimum Part Load Ratio 1.2, !- Maximum Part Load Ratio 1.0, !- Optimum Part Load Ratio HeatSys1 Pump-HeatSys1 BoilerNode, !- Boiler Water Inlet Node Name HeatSys1 Supply Equipment Outlet Node, !- Boiler Water Outlet Node Name 95.0, !- Water Outlet Upper Temperature Limit {C} LeavingSetpointModulated;!- Boiler Flow Mode SetpointManager:Scheduled, HeatSys1 Boiler Setpoint Manager, !- Name Temperature, !- Control Variable HW-Loop-Temp-Schedule, !- Schedule Name HeatSys1 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name Boiler:HotWater, Dummy Boiler, !- Name NaturalGas, !- Fuel Type 93894.07, !- Nominal Capacity {W} 0.8, !- Nominal Thermal Efficiency LeavingBoiler, !- Efficiency Curve Temperature Evaluation Variable Dummy Boiler Efficiency Curve, !- Normalized Boiler Efficiency Curve Name autosize, !- Design Water Flow Rate {m3/s} 0.0, !- Minimum Part Load Ratio 1.2, !- Maximum Part Load Ratio 1.0, !- Optimum Part Load Ratio Dummy Boiler Inlet Node, !- Boiler Water Inlet Node Name Dummy Boiler Outlet Node,!- Boiler Water Outlet Node Name 95, !- Water Outlet Upper Temperature Limit {C} ConstantFlow; !- Boiler Flow Mode Curve:Quadratic, HeatSys1 Boiler Efficiency Curve, !- Name 1.0, !- Coefficient1 Constant 0.0, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0, !- Minimum Value of x 1; !- Maximum Value of x Curve:Quadratic, Dummy Boiler Efficiency Curve, !- Name 1.0, !- Coefficient1 Constant 0.0, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0, !- Minimum Value of x 1; !- Maximum Value of x !- =========== ALL OBJECTS IN CLASS: Chiller:Electric:ReformulatedEIR =========== Chiller:Electric:ReformulatedEIR, CoolSys1 Chiller1, !- Name 1302254.38, !- Reference Capacity {W} 6.28, !- Reference COP {W/W} 6.6700, !- Reference Leaving Chilled Water Temperature {C} 34.4444, !- Reference Leaving Condenser Water Temperature {C} 0.03697765, !- Reference Chilled Water Flow Rate {m3/s} AutoSize, !- Reference Condenser Water Flow Rate {m3/s} WC_CENT_2010_PB_CAPFT, !- Cooling Capacity Function of Temperature Curve Name WC_CENT_2010_PB_EIRFT, !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name LeavingCondenserWaterTemperature, !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Type WC_CENT_300to600_2010_PB_EIRFPLR, !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name 0.1000, !- Minimum Part Load Ratio 1.0000, !- Maximum Part Load Ratio 1.0000, !- Optimum Part Load Ratio 0.1000, !- Minimum Unloading Ratio CoolSys1 Pump-CoolSys1 Chiller1Node, !- Chilled Water Inlet Node Name CoolSys1 Supply Equipment Outlet Node 1, !- Chilled Water Outlet Node Name CoolSys1 Chiller1 Water Inlet Node, !- Condenser Inlet Node Name CoolSys1 Chiller1 Water Outlet Node, !- Condenser Outlet Node Name , !- Fraction of Compressor Electric Consumption Rejected by Condenser 5.0000, !- Leaving Chilled Water Lower Temperature Limit {C} ConstantFlow, !- Chiller Flow Mode Type 0.0000; !- Design Heat Recovery Water Flow Rate {m3/s} Chiller:Electric:ReformulatedEIR, CoolSys1 Chiller2, !- Name 1302254.38, !- Reference Capacity {W} 6.28, !- Reference COP {W/W} 6.6700, !- Reference Leaving Chilled Water Temperature {C} 34.4444, !- Reference Leaving Condenser Water Temperature {C} 0.03697765, !- Reference Chilled Water Flow Rate {m3/s} AutoSize, !- Reference Condenser Water Flow Rate {m3/s} WC_CENT_2010_PB_CAPFT, !- Cooling Capacity Function of Temperature Curve Name WC_CENT_2010_PB_EIRFT, !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name LeavingCondenserWaterTemperature, !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Type WC_CENT_300to600_2010_PB_EIRFPLR, !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name 0.1000, !- Minimum Part Load Ratio 1.0000, !- Maximum Part Load Ratio 1.0000, !- Optimum Part Load Ratio 0.1000, !- Minimum Unloading Ratio CoolSys1 Pump-CoolSys1 Chiller2Node, !- Chilled Water Inlet Node Name CoolSys1 Supply Equipment Outlet Node 2, !- Chilled Water Outlet Node Name CoolSys1 Chiller2 Water Inlet Node, !- Condenser Inlet Node Name CoolSys1 Chiller2 Water Outlet Node, !- Condenser Outlet Node Name , !- Fraction of Compressor Electric Consumption Rejected by Condenser 5.0000, !- Leaving Chilled Water Lower Temperature Limit {C} ConstantFlow, !- Chiller Flow Mode Type 0.0000; !- Design Heat Recovery Water Flow Rate {m3/s} !- =========== ALL OBJECTS IN CLASS: WATER HEATER:MIXED =========== WaterHeater:Mixed, SHWSys1 Water Heater, !- Name 1.135624, !- Tank Volume {m3} SHWSys1 Water Heater Setpoint Temperature Schedule, !- Setpoint Temperature Schedule Name 2.0, !- Deadband Temperature Difference {deltaC} 82.2222, !- Maximum Temperature Limit {C} Cycle, !- Heater Control Type 87921.32, !- Heater Maximum Capacity {W} , !- Heater Minimum Capacity {W} , !- Heater Ignition Minimum Flow Rate {m3/s} , !- Heater Ignition Delay {s} NATURALGAS, !- Heater Fuel Type 0.803988738, !- Heater Thermal Efficiency , !- Part Load Factor Curve Name 7280.88, !- Off Cycle Parasitic Fuel Consumption Rate {W} NATURALGAS, !- Off Cycle Parasitic Fuel Type 0.8, !- Off Cycle Parasitic Heat Fraction to Tank 7280.88, !- On Cycle Parasitic Fuel Consumption Rate {W} NATURALGAS, !- On Cycle Parasitic Fuel Type , !- On Cycle Parasitic Heat Fraction to Tank zone, !- Ambient Temperature Indicator , !- Ambient Temperature Schedule Name BASEMENT, !- Ambient Temperature Zone Name , !- Ambient Temperature Outdoor Air Node Name 11.25413987, !- Off Cycle Loss Coefficient to Ambient Temperature {W/K} , !- Off Cycle Loss Fraction to Zone 11.25413987, !- On Cycle Loss Coefficient to Ambient Temperature {W/K} , !- On Cycle Loss Fraction to Zone , !- Peak Use Flow Rate {m3/s} , !- Use Flow Rate Fraction Schedule Name , !- Cold Water Supply Temperature Schedule Name SHWSys1 Pump-SHWSys1 Water HeaterNode, !- Use Side Inlet Node Name SHWSys1 Supply Equipment Outlet Node, !- Use Side Outlet Node Name 1.0, !- Use Side Effectiveness , !- Source Side Inlet Node Name , !- Source Side Outlet Node Name 1.0, !- Source Side Effectiveness AUTOSIZE, !- Use Side Design Flow Rate {m3/s} AUTOSIZE, !- Source Side Design Flow Rate {m3/s} 1.5; !- Indirect Water Heating Recovery Time {hr} !- =========== ALL OBJECTS IN CLASS: COOLING TOWER:TWO SPEED =========== !- Design Outdoor Air Wet-Bulb Temperature from the EPW file !- Design Range Temperature is set to 10 deltaF per 90.1-2010 G3.1.3.13 !- Design Approach Temperature. Per 90.1-2010 G3.1.3.13, condenser water design supply temperature shall be !- 85F or 10F approaching design wet-bulb temperature, whichever is lower, with a design temperature rise of 10F (range temperature). !- Therefore, we use Design Approach Temperature to set condenser water design supply temperature, i.e. Design Approach Temperature = min(10F, (85 - Design OA WbT from EPW)) CoolingTower:VariableSpeed, TowerWaterSys CoolTower 1, !- Name TowerWaterSys Pump-TowerWaterSys CoolTower1Node, !- Water Inlet Node Name TowerWaterSys Supply Equipment Outlet Node 1, !- Water Outlet Node Name CoolToolsCrossFlow, !- Model Type , !- Model Coefficient Name 24.9, !- Design Inlet Air Wet-Bulb Temperature {C} 4.54444444444444, !- Design Approach Temperature {deltaC} 5.55555555555556, !- Design Range Temperature {deltaC} 0.05355, !- Design Water Flow Rate {m3/s} autosize, !- Design Air Flow Rate {m3/s} 18925.9767634185, !- Design Fan Power {W} Tower_Fan_Curve, !- Fan Power Ratio Function of Air Flow Rate Ratio Curve Name 0.2, !- Minimum Air Flow Rate Ratio 0.125, !- Fraction of Tower Capacity in Free Convection Regime , !- Basin Heater Capacity {W/K} , !- Basin Heater Setpoint Temperature {C} , !- Basin Heater Operating Schedule Name , !- Evaporation Loss Mode , !- Evaporation Loss Factor {percent/K} , !- Drift Loss Percent {percent} , !- Blowdown Calculation Mode , !- Blowdown Concentration Ratio , !- Blowdown Makeup Water Usage Schedule Name , !- Supply Water Storage Tank Name , !- Outdoor Air Inlet Node Name 2, !- Number of Cells MaximalCell, !- Cell Control !- Cell Control , !- Cell Minimum Water Flow Rate Fraction , !- Cell Maximum Water Flow Rate Fraction 1.000; !- Sizing Factor CoolingTower:VariableSpeed, TowerWaterSys CoolTower 2, !- Name TowerWaterSys Pump-TowerWaterSys CoolTower2Node, !- Water Inlet Node Name TowerWaterSys Supply Equipment Outlet Node 2, !- Water Outlet Node Name CoolToolsCrossFlow, !- Model Type , !- Model Coefficient Name 24.9, !- Design Inlet Air Wet-Bulb Temperature {C} 4.54444444444444, !- Design Approach Temperature {deltaC} 5.55555555555556, !- Design Range Temperature {deltaC} 0.05355, !- Design Water Flow Rate {m3/s} autosize, !- Design Air Flow Rate {m3/s} 18925.9767634185, !- Design Fan Power {W} Tower_Fan_Curve, !- Fan Power Ratio Function of Air Flow Rate Ratio Curve Name 0.2, !- Minimum Air Flow Rate Ratio 0.125, !- Fraction of Tower Capacity in Free Convection Regime , !- Basin Heater Capacity {W/K} , !- Basin Heater Setpoint Temperature {C} , !- Basin Heater Operating Schedule Name , !- Evaporation Loss Mode , !- Evaporation Loss Factor {percent/K} , !- Drift Loss Percent {percent} , !- Blowdown Calculation Mode , !- Blowdown Concentration Ratio , !- Blowdown Makeup Water Usage Schedule Name , !- Supply Water Storage Tank Name , !- Outdoor Air Inlet Node Name 2, !- Number of Cells MaximalCell, !- Cell Control !- Cell Control , !- Cell Minimum Water Flow Rate Fraction , !- Cell Maximum Water Flow Rate Fraction 1.000; !- Sizing Factor !- =========== ALL OBJECTS IN CLASS: FLUIDCOOLER:SINGLESPEED =========== !- Based on EnergyPlus 9.0 Reference, default !- Low Fan Speed U-Factor Times Area Sizing Factor 0.6 !- Low Speed Nominal Capacity Sizing Factor 0.5 !- Low Fan Speed Air Flow Rate Sizing Factor 0.5 !- Low Fan Speed Fan Power Sizing Factor 0.16 FluidCooler:TwoSpeed, Central Tower, !- Name Central Tower Inlet Node,!- Water Inlet Node Name Central Tower Outlet Node, !- Water Outlet Node Name NominalCapacity, !- Performance Input Method , !- High Fan Speed U-factor Times Area Value {W/K} , !- Low Fan Speed U-factor Times Area Value {W/K} 0.6, !- Low Fan Speed U-Factor Times Area Sizing Factor 582060, !- High Speed Nominal Capacity {W} 291030, !- Low Speed Nominal Capacity {W} 0.5, !- Low Speed Nominal Capacity Sizing Factor 51.67, !- Design Entering Water Temperature {C} 35, !- Design Entering Air Temperature {C} 25.6, !- Design Entering Air Wet-bulb Temperature {C} autosize, !- Design Water Flow Rate {m3/s} autosize, !- High Fan Speed Air Flow Rate {m3/s} 43776.2410666667, !- High Fan Speed Fan Power {W} autocalculate, !- Low Fan Speed Air Flow Rate {m3/s} 0.5, !- Low Fan Speed Air Flow Rate Sizing Factor autocalculate, !- Low Fan Speed Fan Power {W} 0.16; !- Low Fan Speed Fan Power Sizing Factor !- =========== ALL OBJECTS IN CLASS: PUMP:VARIABLE SPEED =========== Pump:ConstantSpeed, SHWSys1 Pump, !- Name SHWSys1 Supply Inlet Node, !- Inlet Node Name SHWSys1 Pump-SHWSys1 Water HeaterNodeviaConnector, !- Outlet Node Name AUTOSIZE, !- Design Flow Rate {m3/s} 29891, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 0.30, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream Intermittent; !- Pump Control Type Pump:VariableSpeed, HeatSys1 Pump, !- Name HeatSys1 Supply Inlet Node, !- Inlet Node Name HeatSys1 Pump-HeatSys1 BoilerNodeviaConnector, !- Outlet Node Name AUTOSIZE, !- Design Maximum Flow Rate {m3/s} 179352, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 0.909, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream 0,0.0205, 0.4101,0.5753, !- VariableSpeed Pump Curve Coefficients 0, !- Minimum Flow Rate {m3/s} Intermittent; Pump:ConstantSpeed, CoolSys1 Chiller1 Pump, !- Name CoolSys1 Chiller1 Pump Inlet Node, !- Inlet Node Name CoolSys1 Pump-CoolSys1 Chiller1Node, !- Outlet Node Name AUTOSIZE, !- Design Flow Rate {m3/s} 44761.27683, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 0.909, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream Intermittent, !- Pump Control Type ; !- Pump Flow Rate Schedule Name Pump:ConstantSpeed, CoolSys1 Chiller2 Pump, !- Name CoolSys1 Chiller2 Pump Inlet Node, !- Inlet Node Name CoolSys1 Pump-CoolSys1 Chiller2Node, !- Outlet Node Name AUTOSIZE, !- Design Flow Rate {m3/s} 44761.27683, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 0.909, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream Intermittent, !- Pump Control Type ; !- Pump Flow Rate Schedule Name Pump:VariableSpeed, CoolSys1 Pump Secondary, !- Name CoolSys1 Demand Inlet Node, !- Inlet Node Name CoolSys1 Pump Secondary-CoolSys1 Demand Mixer, !- Outlet Node Name autosize, !- Design Maximum Flow Rate {m3/s} 134283.8305, !- Design Pump Head {Pa} autosize, !- Design Power Consumption {W} 0.909, !- Motor Efficiency 0, !- Fraction of Motor Inefficiencies to Fluid Stream 0,0.0205, 0.4101,0.5753, !- VariableSpeed Pump Curve Coefficients 0, !- Minimum Flow Rate {m3/s} Intermittent; !- =========== ALL OBJECTS IN CLASS: PUMP:CONSTANT SPEED =========== Pump:ConstantSpeed, Plant Circ Pump, !- Name Plant Supply Inlet Node, !- Inlet Node Name Plant Pump Outlet Node, !- Outlet Node Name autosize, !- Design Flow Rate {m3/s} 179045.1073, !- Design Pump Head {Pa} autosize, !- Design Power Consumption {W} 0.909, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream Intermittent; !- Pump Control Type HeaderedPumps:VariableSpeed, TowerWaterSys Pump, !- Name TowerWaterSys Supply Inlet Node, !- Inlet Node Name TowerWaterSys Pump-TowerWaterSys CoolTowerNodeviaConnector, !- Outlet Node Name AUTOSIZE, !- Total Design Flow Rate {m3/s} 2, !- Number of Pumps in Bank SEQUENTIAL, !- Flow Sequencing Control Scheme 148556.6249, !- Design Pump Head {Pa} autosize, !- Design Power Consumption {W} 0.909, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream 0, !- Coefficient 1 of the Part Load Performance Curve 0.0216, !- Coefficient 2 of the Part Load Performance Curve -0.0325, !- Coefficient 3 of the Part Load Performance Curve 1.0095, !- Coefficient 4 of the Part Load Performance Curve 0, !- Minimum Flow Rate Fraction Intermittent, !- Pump Control Type ; !- Pump Flow Rate Schedule Name !- =========== ALL OBJECTS IN CLASS: COIL:WATER:COOLING =========== Coil:Cooling:Water, CAV_bas_CoolC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Design Water Flow Rate {m3/s} AUTOSIZE, !- Design Air Flow Rate {m3/s} AUTOSIZE, !- Design Inlet Water Temperature {C} AUTOSIZE, !- Design Inlet Air Temperature {C} AUTOSIZE, !- Design Outlet Air Temperature {C} AUTOSIZE, !- Design Inlet Air Humidity Ratio {kgWater/kgDryAir} AUTOSIZE, !- Design Outlet Air Humidity Ratio {kgWater/kgDryAir} CAV_bas_CoolCDemand Inlet Node, !- Water Inlet Node Name CAV_bas_CoolCDemand Outlet Node, !- Water Outlet Node Name CAV_bas_OA-CAV_CoolCNode,!- Air Inlet Node Name CAV_bas_CoolC-CAV_HeatCNode, !- Air Outlet Node Name SimpleAnalysis, !- Type of Analysis CrossFlow; !- Heat Exchanger Configuration Coil:Cooling:Water, VAV_bot WITH REHEAT_CoolC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Design Water Flow Rate {m3/s} AUTOSIZE, !- Design Air Flow Rate {m3/s} AUTOSIZE, !- Design Inlet Water Temperature {C} AUTOSIZE, !- Design Inlet Air Temperature {C} AUTOSIZE, !- Design Outlet Air Temperature {C} AUTOSIZE, !- Design Inlet Air Humidity Ratio {kgWater/kgDryAir} AUTOSIZE, !- Design Outlet Air Humidity Ratio {kgWater/kgDryAir} VAV_bot WITH REHEAT_CoolCDemand Inlet Node, !- Water Inlet Node Name VAV_bot WITH REHEAT_CoolCDemand Outlet Node, !- Water Outlet Node Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Air Inlet Node Name VAV_bot WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Air Outlet Node Name SimpleAnalysis, !- Type of Analysis CrossFlow; !- Heat Exchanger Configuration Coil:Cooling:Water, VAV_mid WITH REHEAT_CoolC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Design Water Flow Rate {m3/s} AUTOSIZE, !- Design Air Flow Rate {m3/s} AUTOSIZE, !- Design Inlet Water Temperature {C} AUTOSIZE, !- Design Inlet Air Temperature {C} AUTOSIZE, !- Design Outlet Air Temperature {C} AUTOSIZE, !- Design Inlet Air Humidity Ratio {kgWater/kgDryAir} AUTOSIZE, !- Design Outlet Air Humidity Ratio {kgWater/kgDryAir} VAV_mid WITH REHEAT_CoolCDemand Inlet Node, !- Water Inlet Node Name VAV_mid WITH REHEAT_CoolCDemand Outlet Node, !- Water Outlet Node Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Air Inlet Node Name VAV_mid WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Air Outlet Node Name SimpleAnalysis, !- Type of Analysis CrossFlow; !- Heat Exchanger Configuration Coil:Cooling:Water, VAV_top WITH REHEAT_CoolC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Design Water Flow Rate {m3/s} AUTOSIZE, !- Design Air Flow Rate {m3/s} AUTOSIZE, !- Design Inlet Water Temperature {C} AUTOSIZE, !- Design Inlet Air Temperature {C} AUTOSIZE, !- Design Outlet Air Temperature {C} AUTOSIZE, !- Design Inlet Air Humidity Ratio {kgWater/kgDryAir} AUTOSIZE, !- Design Outlet Air Humidity Ratio {kgWater/kgDryAir} VAV_top WITH REHEAT_CoolCDemand Inlet Node, !- Water Inlet Node Name VAV_top WITH REHEAT_CoolCDemand Outlet Node, !- Water Outlet Node Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Air Inlet Node Name VAV_top WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Air Outlet Node Name SimpleAnalysis, !- Type of Analysis CrossFlow; !- Heat Exchanger Configuration !- =========== ALL OBJECTS IN CLASS: COIL:WATER:SIMPLEHEATING =========== Coil:Heating:Water, DataCenter_ExtraWaterHeatC, !- Name DataCenter_ExtraWaterHeatC_Sch, !- Availability Schedule Name , !- U-Factor Times Area Value {W/K} , !- Maximum Water Flow Rate {m3/s} DataCenter_ExtraWaterHeatCDemand Inlet Node, !- Water Inlet Node Name DataCenter_ExtraWaterHeatCDemand Outlet Node, !- Water Outlet Node Name DataCenter_ExtraElecHeatC-DataCenter_ExtraWaterHeatCNode, !- Air Inlet Node Name AirLoop DataCenter Basement Supply Air Outlet, !- Air Outlet Node Name NominalCapacity, !- Performance Input Method 0, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 16.6, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 32.2, !- Rated Outlet Air Temperature {C} 0.5; !- Rated Ratio for Air and Water Convection Coil:Heating:Electric, DataCenter_ExtraElecHeatC, !- Name DataCenter_ExtraElecHeatC_Sch, !- Availability Schedule Name 1.0000, !- Efficiency 10000000, !- Nominal Capacity {W} DataCenter_Humidifier-DataCenter_ExtraElecHeatCNode, !- Air Inlet Node Name DataCenter_ExtraElecHeatC-DataCenter_ExtraWaterHeatCNode, !- Air Outlet Node Name DataCenter_ExtraElecHeatC-DataCenter_ExtraWaterHeatCNode; !- Temperature Setpoint Node Name Coil:Heating:Water, Core_bottom VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Core_bottom VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Core_bottom VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Core_bottom VAV Box Damper Node, !- Air Inlet Node Name Core_bottom VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Core_mid VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Core_mid VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Core_mid VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Core_mid VAV Box Damper Node, !- Air Inlet Node Name Core_mid VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Core_top VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Core_top VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Core_top VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Core_top VAV Box Damper Node, !- Air Inlet Node Name Core_top VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_bot_ZN_3 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_bot_ZN_3 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_bot_ZN_3 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_bot_ZN_3 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_bot_ZN_3 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_bot_ZN_2 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_bot_ZN_2 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_bot_ZN_2 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_bot_ZN_2 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_bot_ZN_2 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_bot_ZN_1 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_bot_ZN_1 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_bot_ZN_1 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_bot_ZN_1 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_bot_ZN_1 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_bot_ZN_4 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_bot_ZN_4 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_bot_ZN_4 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_bot_ZN_4 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_bot_ZN_4 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_mid_ZN_3 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_mid_ZN_3 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_mid_ZN_3 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_mid_ZN_3 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_mid_ZN_3 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_mid_ZN_2 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_mid_ZN_2 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_mid_ZN_2 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_mid_ZN_2 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_mid_ZN_2 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_mid_ZN_1 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_mid_ZN_1 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_mid_ZN_1 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_mid_ZN_1 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_mid_ZN_1 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_mid_ZN_4 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_mid_ZN_4 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_mid_ZN_4 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_mid_ZN_4 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_mid_ZN_4 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_top_ZN_3 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_top_ZN_3 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_top_ZN_3 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_top_ZN_3 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_top_ZN_3 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_top_ZN_2 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_top_ZN_2 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_top_ZN_2 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_top_ZN_2 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_top_ZN_2 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_top_ZN_1 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_top_ZN_1 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_top_ZN_1 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_top_ZN_1 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_top_ZN_1 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, Perimeter_top_ZN_4 VAV Box Reheat Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} Perimeter_top_ZN_4 VAV Box Reheat CoilDemand Inlet Node, !- Water Inlet Node Name Perimeter_top_ZN_4 VAV Box Reheat CoilDemand Outlet Node, !- Water Outlet Node Name Perimeter_top_ZN_4 VAV Box Damper Node, !- Air Inlet Node Name Perimeter_top_ZN_4 VAV Box Outlet Node, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, CAV_bas_HeatC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} CAV_bas_HeatCDemand Inlet Node, !- Water Inlet Node Name CAV_bas_HeatCDemand Outlet Node, !- Water Outlet Node Name CAV_bas_CoolC-CAV_HeatCNode, !- Air Inlet Node Name CAV_bas_HeatC-CAV_FanNode, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, VAV_bot WITH REHEAT_HeatC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} VAV_bot WITH REHEAT_HeatCDemand Inlet Node, !- Water Inlet Node Name VAV_bot WITH REHEAT_HeatCDemand Outlet Node, !- Water Outlet Node Name VAV_bot WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Air Inlet Node Name VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, VAV_mid WITH REHEAT_HeatC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} VAV_mid WITH REHEAT_HeatCDemand Inlet Node, !- Water Inlet Node Name VAV_mid WITH REHEAT_HeatCDemand Outlet Node, !- Water Outlet Node Name VAV_mid WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Air Inlet Node Name VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection Coil:Heating:Water, VAV_top WITH REHEAT_HeatC, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- U-Factor Times Area Value {W/K} AUTOSIZE, !- Maximum Water Flow Rate {m3/s} VAV_top WITH REHEAT_HeatCDemand Inlet Node, !- Water Inlet Node Name VAV_top WITH REHEAT_HeatCDemand Outlet Node, !- Water Outlet Node Name VAV_top WITH REHEAT_CoolC-VAV WITH REHEAT_HeatCNode, !- Air Inlet Node Name VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Air Outlet Node Name UFactorTimesAreaAndDesignWaterFlowRate, !- Performance Input Method AUTOSIZE, !- Rated Capacity {W} 82.2, !- Rated Inlet Water Temperature {C} 12.8, !- Rated Inlet Air Temperature {C} 71.1, !- Rated Outlet Water Temperature {C} 40.0, !- Rated Outlet Air Temperature {C} ; !- Rated Ratio for Air and Water Convection !- =========== ALL OBJECTS IN CLASS: COIL:HEATING:ELECTRIC =========== Coil:Heating:Electric, Heat Pump DX Supp Heating Coil AirLoop DataCenter Basement, !- Name ALWAYS_OFF, !- Availability Schedule Name 1, !- Efficiency autosize, !- Nominal Capacity {W} Heating Coil Air Outlet Node AirLoop DataCenter Basement, !- Air Inlet Node Name AirLoop DataCenter Basement Humidifier Inlet; !- Air Outlet Node Name Coil:Heating:Electric, Heat Pump DX Supp Heating Coil AirLoop DataCenter bot, !- Name ALWAYS_OFF, !- Availability Schedule Name 1, !- Efficiency autosize, !- Nominal Capacity {W} Heating Coil Air Outlet Node AirLoop DataCenter bot, !- Air Inlet Node Name AirLoop DataCenter bot Supply Air Outlet; !- Air Outlet Node Name Coil:Heating:Electric, Heat Pump DX Supp Heating Coil AirLoop DataCenter mid, !- Name ALWAYS_OFF, !- Availability Schedule Name 1, !- Efficiency autosize, !- Nominal Capacity {W} Heating Coil Air Outlet Node AirLoop DataCenter mid, !- Air Inlet Node Name AirLoop DataCenter mid Supply Air Outlet; !- Air Outlet Node Name Coil:Heating:Electric, Heat Pump DX Supp Heating Coil AirLoop DataCenter top, !- Name ALWAYS_OFF, !- Availability Schedule Name 1, !- Efficiency autosize, !- Nominal Capacity {W} Heating Coil Air Outlet Node AirLoop DataCenter top, !- Air Inlet Node Name AirLoop DataCenter top Supply Air Outlet; !- Air Outlet Node Name !- =========== ALL OBJECTS IN CLASS: COIL:COOLING:WATERTOAIRHEATPUMP:EQUATIONFIT =========== Coil:Cooling:WaterToAirHeatPump:EquationFit, Heat Pump Cooling Mode AirLoop DataCenter Basement, !- Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side1 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side1 Outlet Node, !- Water Outlet Node Name AirLoop DataCenter Basement Supply Fan Outlet, !- Air Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter Basement, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Total Cooling Capacity {W} autosize, !- Gross Rated Sensible Cooling Capacity {W} 3.878739046, !- Gross Rated Cooling COP -4.30266987344639, !- Total Cooling Capacity Coefficient 1 7.18536990534372, !- Total Cooling Capacity Coefficient 2 -2.23946714486189, !- Total Cooling Capacity Coefficient 3 0.139995928440879, !- Total Cooling Capacity Coefficient 4 0.102660179888915, !- Total Cooling Capacity Coefficient 5 6.0019444814887, !- Sensible Cooling Capacity Coefficient 1 22.6300677244073, !- Sensible Cooling Capacity Coefficient 2 -26.7960783730934, !- Sensible Cooling Capacity Coefficient 3 -1.72374720346819, !- Sensible Cooling Capacity Coefficient 4 0.490644802367817, !- Sensible Cooling Capacity Coefficient 5 0.0693119353468141, !- Sensible Cooling Capacity Coefficient 6 -5.67775976415698, !- Cooling Power Consumption Coefficient 1 0.438988156976704, !- Cooling Power Consumption Coefficient 2 5.845277342193, !- Cooling Power Consumption Coefficient 3 0.141605667000125, !- Cooling Power Consumption Coefficient 4 -0.168727936032429, !- Cooling Power Consumption Coefficient 5 0, !- Nominal Time for Condensate Removal to Begin {s} 0; !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity {dimensionless} Coil:Cooling:WaterToAirHeatPump:EquationFit, Heat Pump Cooling Mode AirLoop DataCenter bot, !- Name AirLoop DataCenter bot Water to Air Heat Pump Source Side1 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter bot Water to Air Heat Pump Source Side1 Outlet Node, !- Water Outlet Node Name AirLoop DataCenter bot Supply Fan Outlet, !- Air Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter bot, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Total Cooling Capacity {W} autosize, !- Gross Rated Sensible Cooling Capacity {W} 4.005260634, !- Gross Rated Cooling COP -4.30266987344639, !- Total Cooling Capacity Coefficient 1 7.18536990534372, !- Total Cooling Capacity Coefficient 2 -2.23946714486189, !- Total Cooling Capacity Coefficient 3 0.139995928440879, !- Total Cooling Capacity Coefficient 4 0.102660179888915, !- Total Cooling Capacity Coefficient 5 6.0019444814887, !- Sensible Cooling Capacity Coefficient 1 22.6300677244073, !- Sensible Cooling Capacity Coefficient 2 -26.7960783730934, !- Sensible Cooling Capacity Coefficient 3 -1.72374720346819, !- Sensible Cooling Capacity Coefficient 4 0.490644802367817, !- Sensible Cooling Capacity Coefficient 5 0.0693119353468141, !- Sensible Cooling Capacity Coefficient 6 -5.67775976415698, !- Cooling Power Consumption Coefficient 1 0.438988156976704, !- Cooling Power Consumption Coefficient 2 5.845277342193, !- Cooling Power Consumption Coefficient 3 0.141605667000125, !- Cooling Power Consumption Coefficient 4 -0.168727936032429, !- Cooling Power Consumption Coefficient 5 0, !- Nominal Time for Condensate Removal to Begin {s} 0; !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity {dimensionless} Coil:Cooling:WaterToAirHeatPump:EquationFit, Heat Pump Cooling Mode AirLoop DataCenter mid, !- Name AirLoop DataCenter mid Water to Air Heat Pump Source Side1 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter mid Water to Air Heat Pump Source Side1 Outlet Node, !- Water Outlet Node Name AirLoop DataCenter mid Supply Fan Outlet, !- Air Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter mid, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Total Cooling Capacity {W} autosize, !- Gross Rated Sensible Cooling Capacity {W} 4.005260634, !- Gross Rated Cooling COP -4.30266987344639, !- Total Cooling Capacity Coefficient 1 7.18536990534372, !- Total Cooling Capacity Coefficient 2 -2.23946714486189, !- Total Cooling Capacity Coefficient 3 0.139995928440879, !- Total Cooling Capacity Coefficient 4 0.102660179888915, !- Total Cooling Capacity Coefficient 5 6.0019444814887, !- Sensible Cooling Capacity Coefficient 1 22.6300677244073, !- Sensible Cooling Capacity Coefficient 2 -26.7960783730934, !- Sensible Cooling Capacity Coefficient 3 -1.72374720346819, !- Sensible Cooling Capacity Coefficient 4 0.490644802367817, !- Sensible Cooling Capacity Coefficient 5 0.0693119353468141, !- Sensible Cooling Capacity Coefficient 6 -5.67775976415698, !- Cooling Power Consumption Coefficient 1 0.438988156976704, !- Cooling Power Consumption Coefficient 2 5.845277342193, !- Cooling Power Consumption Coefficient 3 0.141605667000125, !- Cooling Power Consumption Coefficient 4 -0.168727936032429, !- Cooling Power Consumption Coefficient 5 0, !- Nominal Time for Condensate Removal to Begin {s} 0; !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity {dimensionless} Coil:Cooling:WaterToAirHeatPump:EquationFit, Heat Pump Cooling Mode AirLoop DataCenter top, !- Name AirLoop DataCenter top Water to Air Heat Pump Source Side1 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter top Water to Air Heat Pump Source Side1 Outlet Node, !- Water Outlet Node Name AirLoop DataCenter top Supply Fan Outlet, !- Air Inlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter top, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Total Cooling Capacity {W} autosize, !- Gross Rated Sensible Cooling Capacity {W} 4.005260634, !- Gross Rated Cooling COP -4.30266987344639, !- Total Cooling Capacity Coefficient 1 7.18536990534372, !- Total Cooling Capacity Coefficient 2 -2.23946714486189, !- Total Cooling Capacity Coefficient 3 0.139995928440879, !- Total Cooling Capacity Coefficient 4 0.102660179888915, !- Total Cooling Capacity Coefficient 5 6.0019444814887, !- Sensible Cooling Capacity Coefficient 1 22.6300677244073, !- Sensible Cooling Capacity Coefficient 2 -26.7960783730934, !- Sensible Cooling Capacity Coefficient 3 -1.72374720346819, !- Sensible Cooling Capacity Coefficient 4 0.490644802367817, !- Sensible Cooling Capacity Coefficient 5 0.0693119353468141, !- Sensible Cooling Capacity Coefficient 6 -5.67775976415698, !- Cooling Power Consumption Coefficient 1 0.438988156976704, !- Cooling Power Consumption Coefficient 2 5.845277342193, !- Cooling Power Consumption Coefficient 3 0.141605667000125, !- Cooling Power Consumption Coefficient 4 -0.168727936032429, !- Cooling Power Consumption Coefficient 5 0, !- Nominal Time for Condensate Removal to Begin {s} 0; !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity {dimensionless} !- =========== ALL OBJECTS IN CLASS: COIL:HEATING:WATERTOAIRHEATPUMP:EQUATIONFIT =========== Coil:Heating:WaterToAirHeatPump:EquationFit, Heat Pump HEATING Mode AirLoop DataCenter Basement, !- Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side2 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter Basement Water to Air Heat Pump Source Side2 Outlet Node, !- Water Outlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter Basement, !- Air Inlet Node Name Heating Coil Air Outlet Node AirLoop DataCenter Basement, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Heating Capacity {W} 4.2, !- Gross Rated Heating COP 0.237847462869254, !- Heating Capacity Coefficient 1 -3.35823796081626, !- Heating Capacity Coefficient 2 3.80640467406376, !- Heating Capacity Coefficient 3 0.179200417311554, !- Heating Capacity Coefficient 4 0.12860719846082, !- Heating Capacity Coefficient 5 -3.79175529243238, !- Heating Power Consumption Coefficient 1 3.38799239505527, !- Heating Power Consumption Coefficient 2 1.5022612076303, !- Heating Power Consumption Coefficient 3 -0.177653510577989, !- Heating Power Consumption Coefficient 4 -0.103079864171839; !- Heating Power Consumption Coefficient 5 Coil:Heating:WaterToAirHeatPump:EquationFit, Heat Pump HEATING Mode AirLoop DataCenter bot, !- Name AirLoop DataCenter bot Water to Air Heat Pump Source Side2 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter bot Water to Air Heat Pump Source Side2 Outlet Node, !- Water Outlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter bot, !- Air Inlet Node Name Heating Coil Air Outlet Node AirLoop DataCenter bot, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Heating Capacity {W} 4.2, !- Gross Rated Heating COP 0.237847462869254, !- Heating Capacity Coefficient 1 -3.35823796081626, !- Heating Capacity Coefficient 2 3.80640467406376, !- Heating Capacity Coefficient 3 0.179200417311554, !- Heating Capacity Coefficient 4 0.12860719846082, !- Heating Capacity Coefficient 5 -3.79175529243238, !- Heating Power Consumption Coefficient 1 3.38799239505527, !- Heating Power Consumption Coefficient 2 1.5022612076303, !- Heating Power Consumption Coefficient 3 -0.177653510577989, !- Heating Power Consumption Coefficient 4 -0.103079864171839; !- Heating Power Consumption Coefficient 5 Coil:Heating:WaterToAirHeatPump:EquationFit, Heat Pump HEATING Mode AirLoop DataCenter mid, !- Name AirLoop DataCenter mid Water to Air Heat Pump Source Side2 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter mid Water to Air Heat Pump Source Side2 Outlet Node, !- Water Outlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter mid, !- Air Inlet Node Name Heating Coil Air Outlet Node AirLoop DataCenter mid, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Heating Capacity {W} 4.2, !- Gross Rated Heating COP 0.237847462869254, !- Heating Capacity Coefficient 1 -3.35823796081626, !- Heating Capacity Coefficient 2 3.80640467406376, !- Heating Capacity Coefficient 3 0.179200417311554, !- Heating Capacity Coefficient 4 0.12860719846082, !- Heating Capacity Coefficient 5 -3.79175529243238, !- Heating Power Consumption Coefficient 1 3.38799239505527, !- Heating Power Consumption Coefficient 2 1.5022612076303, !- Heating Power Consumption Coefficient 3 -0.177653510577989, !- Heating Power Consumption Coefficient 4 -0.103079864171839; !- Heating Power Consumption Coefficient 5 Coil:Heating:WaterToAirHeatPump:EquationFit, Heat Pump HEATING Mode AirLoop DataCenter top, !- Name AirLoop DataCenter top Water to Air Heat Pump Source Side2 Inlet Node, !- Water Inlet Node Name AirLoop DataCenter top Water to Air Heat Pump Source Side2 Outlet Node, !- Water Outlet Node Name Cooling Coil Air Outlet Node AirLoop DataCenter top, !- Air Inlet Node Name Heating Coil Air Outlet Node AirLoop DataCenter top, !- Air Outlet Node Name autosize, !- Rated Air Flow Rate {m3/s} autosize, !- Rated Water Flow Rate {m3/s} autosize, !- Gross Rated Heating Capacity {W} 4.2, !- Gross Rated Heating COP 0.237847462869254, !- Heating Capacity Coefficient 1 -3.35823796081626, !- Heating Capacity Coefficient 2 3.80640467406376, !- Heating Capacity Coefficient 3 0.179200417311554, !- Heating Capacity Coefficient 4 0.12860719846082, !- Heating Capacity Coefficient 5 -3.79175529243238, !- Heating Power Consumption Coefficient 1 3.38799239505527, !- Heating Power Consumption Coefficient 2 1.5022612076303, !- Heating Power Consumption Coefficient 3 -0.177653510577989, !- Heating Power Consumption Coefficient 4 -0.103079864171839; !- Heating Power Consumption Coefficient 5 !- =========== ALL OBJECTS IN CLASS: HUMIDIFIER:STEAM:ELECTRIC =========== Humidifier:Steam:Electric, DataCenter Basement Humidifier, !- Name ALWAYS_ON, !- Availability Schedule Name 3.72E-5, !- Rated Capacity {m3/s} 100000, !- Rated Power {W} 0, !- Rated Fan Power {W} 0, !- Standby Power {W} AirLoop DataCenter Basement Humidifier Inlet, !- Air Inlet Node Name DataCenter_Humidifier-DataCenter_ExtraElecHeatCNode; !- Air Outlet Node Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:UNITARYHEATPUMP:WATERTOAIR =========== AirLoopHVAC:UnitaryHeatPump:WaterToAir, AirLoop DataCenter Basement DXAC Heat Pump, !- Name Always_On, !- Availability Schedule Name DataCenter Basement Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter Basement Humidifier Inlet, !- Air Outlet Node Name autosize, !- Supply Air Flow Rate {m3/s} DataCenter_basement_ZN_6,!- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type DataCenter Basement Supply Fan, !- Supply Air Fan Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Heating Coil Object Type Heat Pump HEATING Mode AirLoop DataCenter Basement, !- Heating Coil Name 0.001, !- Heating Convergence Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Cooling Coil Object Type Heat Pump Cooling Mode AirLoop DataCenter Basement, !- Cooling Coil Name 0.001, !- Cooling Convergence 2.5, !- Maximum Cycling Rate {cycles/hr} 60, !- Heat Pump Time Constant {s} 0.01, !- Fraction of On-Cycle Power Use 60, !- Heat Pump Fan Delay Time {s} Coil:Heating:Electric, !- Supplemental Heating Coil Object Type Heat Pump DX Supp Heating Coil AirLoop DataCenter Basement, !- Supplemental Heating Coil Name 50, !- Maximum Supply Air Temperature from Supplemental Heater {C} , !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} Common OSA Inlet Node, !- Outdoor Dry-Bulb Temperature Sensor Node Name BlowThrough, !- Fan Placement SupplyFanSch; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, AirLoop DataCenter bot DXAC Heat Pump, !- Name Always_On, !- Availability Schedule Name DataCenter bot Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter bot Supply Air Outlet, !- Air Outlet Node Name autosize, !- Supply Air Flow Rate {m3/s} DataCenter_bot_ZN_6, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type DataCenter bot Supply Fan, !- Supply Air Fan Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Heating Coil Object Type Heat Pump HEATING Mode AirLoop DataCenter bot, !- Heating Coil Name 0.001, !- Heating Convergence Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Cooling Coil Object Type Heat Pump Cooling Mode AirLoop DataCenter bot, !- Cooling Coil Name 0.001, !- Cooling Convergence 2.5, !- Maximum Cycling Rate {cycles/hr} 60, !- Heat Pump Time Constant {s} 0.01, !- Fraction of On-Cycle Power Use 60, !- Heat Pump Fan Delay Time {s} Coil:Heating:Electric, !- Supplemental Heating Coil Object Type Heat Pump DX Supp Heating Coil AirLoop DataCenter bot, !- Supplemental Heating Coil Name 50, !- Maximum Supply Air Temperature from Supplemental Heater {C} , !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} Common OSA Inlet Node, !- Outdoor Dry-Bulb Temperature Sensor Node Name BlowThrough, !- Fan Placement SupplyFanSch; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, AirLoop DataCenter mid DXAC Heat Pump, !- Name Always_On, !- Availability Schedule Name DataCenter mid Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter mid Supply Air Outlet, !- Air Outlet Node Name autosize, !- Supply Air Flow Rate {m3/s} DataCenter_mid_ZN_6, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type DataCenter mid Supply Fan, !- Supply Air Fan Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Heating Coil Object Type Heat Pump HEATING Mode AirLoop DataCenter mid, !- Heating Coil Name 0.001, !- Heating Convergence Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Cooling Coil Object Type Heat Pump Cooling Mode AirLoop DataCenter mid, !- Cooling Coil Name 0.001, !- Cooling Convergence 2.5, !- Maximum Cycling Rate {cycles/hr} 60, !- Heat Pump Time Constant {s} 0.01, !- Fraction of On-Cycle Power Use 60, !- Heat Pump Fan Delay Time {s} Coil:Heating:Electric, !- Supplemental Heating Coil Object Type Heat Pump DX Supp Heating Coil AirLoop DataCenter mid, !- Supplemental Heating Coil Name 50, !- Maximum Supply Air Temperature from Supplemental Heater {C} , !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} Common OSA Inlet Node, !- Outdoor Dry-Bulb Temperature Sensor Node Name BlowThrough, !- Fan Placement SupplyFanSch; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:WaterToAir, AirLoop DataCenter top DXAC Heat Pump, !- Name Always_On, !- Availability Schedule Name DataCenter top Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter top Supply Air Outlet, !- Air Outlet Node Name autosize, !- Supply Air Flow Rate {m3/s} DataCenter_top_ZN_6, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type DataCenter top Supply Fan, !- Supply Air Fan Name Coil:Heating:WaterToAirHeatPump:EquationFit, !- Heating Coil Object Type Heat Pump HEATING Mode AirLoop DataCenter top, !- Heating Coil Name 0.001, !- Heating Convergence Coil:Cooling:WaterToAirHeatPump:EquationFit, !- Cooling Coil Object Type Heat Pump Cooling Mode AirLoop DataCenter top, !- Cooling Coil Name 0.001, !- Cooling Convergence 2.5, !- Maximum Cycling Rate {cycles/hr} 60, !- Heat Pump Time Constant {s} 0.01, !- Fraction of On-Cycle Power Use 60, !- Heat Pump Fan Delay Time {s} Coil:Heating:Electric, !- Supplemental Heating Coil Object Type Heat Pump DX Supp Heating Coil AirLoop DataCenter top, !- Supplemental Heating Coil Name 50, !- Maximum Supply Air Temperature from Supplemental Heater {C} , !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} Common OSA Inlet Node, !- Outdoor Dry-Bulb Temperature Sensor Node Name BlowThrough, !- Fan Placement SupplyFanSch; !- Supply Air Fan Operating Mode Schedule Name !- =========== ALL OBJECTS IN CLASS: FAN:CONSTANTVOLUME =========== Fan:ConstantVolume, CAV_bas Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.6006, !- Fan Total Efficiency 1018.41, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.924, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction CAV_bas_HeatC-CAV_FanNode, !- Air Inlet Node Name CAV_bas Supply Equipment Outlet Node; !- Air Outlet Node Name !- =========== ALL OBJECTS IN CLASS: FAN:SIMPLE:VARIABLEVOLUME =========== Fan:VariableVolume, VAV_bot WITH REHEAT Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.6084, !- Fan Total Efficiency 1389.42, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} Fraction, !- Fan Power Minimum Flow Rate Input Method 0.25, !- Fan Power Minimum Flow Fraction , !- Fan Power Minimum Air Flow Rate {m3/s} 0.936, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction 0.0408, !- Fan Power Coefficient 1 0.088, !- Fan Power Coefficient 2 -0.0729, !- Fan Power Coefficient 3 0.9437, !- Fan Power Coefficient 4 0, !- Fan Power Coefficient 5 VAV_bot WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Air Inlet Node Name VAV_bot WITH REHEAT Supply Equipment Outlet Node; !- Air Outlet Node Name Fan:VariableVolume, VAV_mid WITH REHEAT Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.6084, !- Fan Total Efficiency 1389.42, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} Fraction, !- Fan Power Minimum Flow Rate Input Method 0.25, !- Fan Power Minimum Flow Fraction , !- Fan Power Minimum Air Flow Rate {m3/s} 0.936, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction 0.0408, !- Fan Power Coefficient 1 0.088, !- Fan Power Coefficient 2 -0.0729, !- Fan Power Coefficient 3 0.9437, !- Fan Power Coefficient 4 0, !- Fan Power Coefficient 5 VAV_mid WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Air Inlet Node Name VAV_mid WITH REHEAT Supply Equipment Outlet Node; !- Air Outlet Node Name Fan:VariableVolume, VAV_top WITH REHEAT Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.6084, !- Fan Total Efficiency 1389.42, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} Fraction, !- Fan Power Minimum Flow Rate Input Method 0.25, !- Fan Power Minimum Flow Fraction , !- Fan Power Minimum Air Flow Rate {m3/s} 0.936, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction 0.0408, !- Fan Power Coefficient 1 0.088, !- Fan Power Coefficient 2 -0.0729, !- Fan Power Coefficient 3 0.9437, !- Fan Power Coefficient 4 0, !- Fan Power Coefficient 5 VAV_top WITH REHEAT_HeatC-VAV WITH REHEAT FanNode, !- Air Inlet Node Name VAV_top WITH REHEAT Supply Equipment Outlet Node; !- Air Outlet Node Name !- =========== ALL OBJECTS IN CLASS: FAN:ONOFF =========== Fan:OnOff, DataCenter Basement Supply Fan, !- Name Always_On, !- Availability Schedule Name 0.6175, !- Fan Total Efficiency 1018.41, !- Pressure Rise {Pa} autosize, !- Maximum Flow Rate {m3/s} 0.95, !- Motor Efficiency 1, !- Motor In Airstream Fraction DataCenter Basement Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter Basement Supply Fan Outlet; !- Air Outlet Node Name Fan:OnOff, DataCenter bot Supply Fan, !- Name Always_On, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} autosize, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1, !- Motor In Airstream Fraction DataCenter bot Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter bot Supply Fan Outlet; !- Air Outlet Node Name Fan:OnOff, DataCenter mid Supply Fan, !- Name Always_On, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} autosize, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1, !- Motor In Airstream Fraction DataCenter mid Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter mid Supply Fan Outlet; !- Air Outlet Node Name Fan:OnOff, DataCenter top Supply Fan, !- Name Always_On, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} autosize, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1, !- Motor In Airstream Fraction DataCenter top Mixed Air Outlet, !- Air Inlet Node Name AirLoop DataCenter top Supply Fan Outlet; !- Air Outlet Node Name !- =========== ALL OBJECTS IN CLASS: FLUIDPROPERTIES:GLYCOLCONCENTRATIONS =========== FluidProperties:GlycolConcentration, EthyleneGlycol40Percent, !- Name EthyleneGlycol, !- Glycol Type , !- User Defined Glycol Name 0.4; !- Glycol Concentration HeatExchanger:AirToAir:SensibleAndLatent, VAV_bot WITH REHEAT OA Heat Recovery, !- Name Always_On, !- Availability Schedule Name AUTOSIZE, !- Nominal Supply Air Flow Rate {m3/s} 0.70, !- Sensible Effectiveness at 100% Heating Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 100% Heating Air Flow {dimensionless} 0.70, !- Sensible Effectiveness at 75% Heating Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 75% Heating Air Flow {dimensionless} 0.75, !- Sensible Effectiveness at 100% Cooling Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 100% Cooling Air Flow {dimensionless} 0.75, !- Sensible Effectiveness at 75% Cooling Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 75% Cooling Air Flow {dimensionless} VAV_bot WITH REHEAT_OAInlet Node, !- Supply Air Inlet Node Name VAV_bot WITH REHEAT Heat Recovery Outlet Node, !- Supply Air Outlet Node Name VAV_bot WITH REHEAT_OARelief Node, !- Exhaust Air Inlet Node Name VAV_bot WITH REHEAT Heat Recovery Secondary Outlet Node, !- Exhaust Air Outlet Node Name 1506.812, !- Nominal Electric Power {W} Yes, !- Supply Air Outlet Temperature Control Rotary, !- Heat Exchanger Type ExhaustOnly, !- Frost Control Type -23.3, !- Threshold Temperature {C} 0.167, !- Initial Defrost Time Fraction {dimensionless} 1.44; !- Rate of Defrost Time Fraction Increase {1/K} HeatExchanger:AirToAir:SensibleAndLatent, VAV_mid WITH REHEAT OA Heat Recovery, !- Name Always_On, !- Availability Schedule Name AUTOSIZE, !- Nominal Supply Air Flow Rate {m3/s} 0.70, !- Sensible Effectiveness at 100% Heating Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 100% Heating Air Flow {dimensionless} 0.70, !- Sensible Effectiveness at 75% Heating Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 75% Heating Air Flow {dimensionless} 0.75, !- Sensible Effectiveness at 100% Cooling Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 100% Cooling Air Flow {dimensionless} 0.75, !- Sensible Effectiveness at 75% Cooling Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 75% Cooling Air Flow {dimensionless} VAV_mid WITH REHEAT_OAInlet Node, !- Supply Air Inlet Node Name VAV_mid WITH REHEAT Heat Recovery Outlet Node, !- Supply Air Outlet Node Name VAV_mid WITH REHEAT_OARelief Node, !- Exhaust Air Inlet Node Name VAV_mid WITH REHEAT Heat Recovery Secondary Outlet Node, !- Exhaust Air Outlet Node Name 1506.812, !- Nominal Electric Power {W} Yes, !- Supply Air Outlet Temperature Control Rotary, !- Heat Exchanger Type ExhaustOnly, !- Frost Control Type -23.3, !- Threshold Temperature {C} 0.167, !- Initial Defrost Time Fraction {dimensionless} 1.44; !- Rate of Defrost Time Fraction Increase {1/K} HeatExchanger:AirToAir:SensibleAndLatent, VAV_top WITH REHEAT OA Heat Recovery, !- Name Always_On, !- Availability Schedule Name AUTOSIZE, !- Nominal Supply Air Flow Rate {m3/s} 0.70, !- Sensible Effectiveness at 100% Heating Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 100% Heating Air Flow {dimensionless} 0.70, !- Sensible Effectiveness at 75% Heating Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 75% Heating Air Flow {dimensionless} 0.75, !- Sensible Effectiveness at 100% Cooling Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 100% Cooling Air Flow {dimensionless} 0.75, !- Sensible Effectiveness at 75% Cooling Air Flow {dimensionless} 0.60, !- Latent Effectiveness at 75% Cooling Air Flow {dimensionless} VAV_top WITH REHEAT_OAInlet Node, !- Supply Air Inlet Node Name VAV_top WITH REHEAT Heat Recovery Outlet Node, !- Supply Air Outlet Node Name VAV_top WITH REHEAT_OARelief Node, !- Exhaust Air Inlet Node Name VAV_top WITH REHEAT Heat Recovery Secondary Outlet Node, !- Exhaust Air Outlet Node Name 1506.812, !- Nominal Electric Power {W} Yes, !- Supply Air Outlet Temperature Control Rotary, !- Heat Exchanger Type ExhaustOnly, !- Frost Control Type -23.3, !- Threshold Temperature {C} 0.167, !- Initial Defrost Time Fraction {dimensionless} 1.44; !- Rate of Defrost Time Fraction Increase {1/K} Curve:Cubic, Tower_Fan_Curve, !- Name 0, !- Coefficient1 Constant 0, !- Coefficient2 x 0, !- Coefficient3 x**2 1, !- Coefficient4 x**3 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x !- =========== ALL OBJECTS IN CLASS: WATER USE EQUIPMENT =========== WaterUse:Equipment, Core_bottom sub cat, !- Name WaterUse, !- End-Use Subcategory 3.66667e-05, !- Peak Flow Rate {m3/s} BLDG_SWH_SCH, !- Flow Rate Fraction Schedule Name Core_bottom sub cat Temp Sched, !- Target Temperature Schedule Name Core_bottom sub catHot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name Core_bottom, !- Zone Name Core_bottom sub cat Sensible fract sched, !- Sensible Fraction Schedule Name Core_bottom sub cat Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, Core_mid sub cat, !- Name WaterUse, !- End-Use Subcategory 3.66667e-05, !- Peak Flow Rate {m3/s} BLDG_SWH_SCH, !- Flow Rate Fraction Schedule Name Core_mid sub cat Temp Sched, !- Target Temperature Schedule Name Core_mid sub catHot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name Core_mid, !- Zone Name Core_mid sub cat Sensible fract sched, !- Sensible Fraction Schedule Name Core_mid sub cat Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, Core_top sub cat, !- Name WaterUse, !- End-Use Subcategory 3.66667e-05, !- Peak Flow Rate {m3/s} BLDG_SWH_SCH, !- Flow Rate Fraction Schedule Name Core_top sub cat Temp Sched, !- Target Temperature Schedule Name Core_top sub catHot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name Core_top, !- Zone Name Core_top sub cat Sensible fract sched, !- Sensible Fraction Schedule Name Core_top sub cat Latent fract sched; !- Latent Fraction Schedule Name !- =========== ALL OBJECTS IN CLASS: WATER USE CONNECTIONS =========== WaterUse:Connections, Core_bottom sub cat, !- Name Core_bottom sub cat Water Inlet Node, !- Inlet Node Name Core_bottom sub cat Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} Core_bottom sub cat; !- Water Use Equipment 1 Name WaterUse:Connections, Core_mid sub cat, !- Name Core_mid sub cat Water Inlet Node, !- Inlet Node Name Core_mid sub cat Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} Core_mid sub cat; !- Water Use Equipment 1 Name WaterUse:Connections, Core_top sub cat, !- Name Core_top sub cat Water Inlet Node, !- Inlet Node Name Core_top sub cat Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} Core_top sub cat; !- Water Use Equipment 1 Name !No PV for this case EnergyManagementSystem:Sensor, T_OA, !- Name , !- Output:Variable or Output:Meter Index Key Name Site Outdoor Air Drybulb Temperature; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, DataCenter_FanMassFlow, !- Name AirLoop DataCenter Basement Supply Fan Outlet, !- Output:Variable or Output:Meter Index Key Name System Node Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, DataCenter_Humidifier_Status, !- Name DataCenter Basement Humidifier, !- Output:Variable or Output:Meter Index Key Name Humidifier Water Volume Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, DataCenter_CLG_SP, !- Name Cooling Coil Air Outlet Node AirLoop DataCenter Basement, !- Output:Variable or Output:Meter Index Key Name System Node Setpoint Temperature; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, DataCenter_HeatC_Status, !- Name HEAT PUMP HEATING MODE AIRLOOP DATACENTER BASEMENT, !- Output:Variable or Output:Meter Index Key Name Heating Coil Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, DataCenter_AfterHumidifier_Temp, !- Name DataCenter_Humidifier-DataCenter_ExtraElecHeatCNode, !- Output:Variable or Output:Meter Index Key Name System Node Temperature; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, DataCenter_AfterElecHeatC_Temp, !- Name DataCenter_EXTRAELECHEATC-DataCenter_EXTRAWATERHEATCNODE, !- Output:Variable or Output:Meter Index Key Name System Node Temperature; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_bot_WITH_REHEAT_OA_VRP, !- Name VAV_bot WITH REHEAT, !- Output:Variable or Output:Meter Index Key Name Air System Outdoor Air Mechanical Ventilation Requested Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_bot_WITH_REHEAT_OA, !- Name VAV_bot WITH REHEAT, !- Output:Variable or Output:Meter Index Key Name Air System Outdoor Air Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_bot_SUPPLY_FLOW, !- Name VAV_bot WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Output:Variable or Output:Meter Index Key Name System Node Standard Density Volume Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_mid_WITH_REHEAT_OA_VRP, !- Name VAV_mid WITH REHEAT, !- Output:Variable or Output:Meter Index Key Name Air System Outdoor Air Mechanical Ventilation Requested Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_mid_WITH_REHEAT_OA, !- Name VAV_mid WITH REHEAT, !- Output:Variable or Output:Meter Index Key Name Air System Outdoor Air Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_mid_SUPPLY_FLOW, !- Name VAV_mid WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Output:Variable or Output:Meter Index Key Name System Node Standard Density Volume Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_top_WITH_REHEAT_OA_VRP, !- Name VAV_top WITH REHEAT, !- Output:Variable or Output:Meter Index Key Name Air System Outdoor Air Mechanical Ventilation Requested Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_top_WITH_REHEAT_OA, !- Name VAV_top WITH REHEAT, !- Output:Variable or Output:Meter Index Key Name Air System Outdoor Air Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, VAV_top_SUPPLY_FLOW, !- Name VAV_top WITH REHEAT_OA-VAV WITH REHEAT_CoolCNode, !- Output:Variable or Output:Meter Index Key Name System Node Standard Density Volume Flow Rate; !- Output:Variable or Output:Meter Name !- =========== ALL OBJECTS IN CLASS: ENERGYMANAGEMENTSYSTEM:ACTUATOR =========== EnergyManagementSystem:Actuator, DataCenter_ExtraElecHeatC_SP, !- Name DataCenter_EXTRAELECHEATC-DataCenter_EXTRAWATERHEATCNODE, !- Actuated Component Unique Name System Node Setpoint, !- Actuated Component Type Temperature Setpoint; !- Actuated Component Control Type EnergyManagementSystem:Actuator, DataCenter_ExtraWaterHeatC_SP, !- Name AirLoop DataCenter Basement Supply Air Outlet, !- Actuated Component Unique Name System Node Setpoint, !- Actuated Component Type Temperature Setpoint; !- Actuated Component Control Type EnergyManagementSystem:Actuator, DataCenter_ExtraElecHeatC_Status, !- Name DataCenter_ExtraElecHeatC_Sch, !- Actuated Component Unique Name Schedule:Compact, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, DataCenter_ExtraWaterHeatC_Status, !- Name DataCenter_ExtraWaterHeatC_Sch, !- Actuated Component Unique Name Schedule:Compact, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, VAV_bot_WITH_REHEAT_MAX_OA_FRAC, !- Name VAV_bot WITH REHEAT Max OA Fraction, !- Actuated Component Unique Name Schedule:Constant, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, VAV_mid_WITH_REHEAT_MAX_OA_FRAC, !- Name VAV_mid WITH REHEAT Max OA Fraction, !- Actuated Component Unique Name Schedule:Constant, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, VAV_top_WITH_REHEAT_MAX_OA_FRAC, !- Name VAV_top WITH REHEAT Max OA Fraction, !- Actuated Component Unique Name Schedule:Constant, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type !- =========== ALL OBJECTS IN CLASS: ENERGYMANAGEMENTSYSTEM:PROGRAMCALLINGMANAGER =========== EnergyManagementSystem:ProgramCallingManager, DataCenter_Main_Manager, !- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point DataCenter_Main; !- Program Name 1 EnergyManagementSystem:Program, DataCenter_Main, !- Name IF DataCenter_Humidifier_Status > 0, !- Program Line 1 SET DataCenter_ExtraElecHeatC_Status = 0, !- Program Line 2 SET DataCenter_ExtraElecHeatC_SP = DataCenter_AfterHumidifier_Temp + 0.36, !- SET DataCenter_ExtraWaterHeatC_SP = DataCenter_CLG_SP, !- ELSE, !- SET DataCenter_ExtraElecHeatC_Status = 0, !- SET DataCenter_ExtraElecHeatC_SP = NULL, !- ENDIF, !- IF T_OA < 10 && DataCenter_HeatC_Status >0, !- SET HeatGain = 0 * (DataCenter_FanDesignMass/1.2) *2118, !- SET FlowRate = (DataCenter_FanMassFlow/1.2)*2118, !- SET DataCenter_PreheatDeltaT = HeatGain/(1.08*FlowRate), !- SET DataCenter_ExtraWaterHeatC_Status = 1, !- SET DataCenter_ExtraWaterHeatC_SP = DataCenter_AfterElecHeatC_Temp + DataCenter_PreheatDeltaT, !- ELSE, !- SET DataCenter_ExtraWaterHeatC_Status = 0, !- ENDIF; !- EnergyManagementSystem:ProgramCallingManager, VAV_bot_WITH_REHEAT_MAX_OA_FRAC_Prog_Manager,!- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point VAV_bot_WITH_REHEAT_MAX_OA_FRAC; !- Program Name 1 EnergyManagementSystem:Program, VAV_bot_WITH_REHEAT_MAX_OA_FRAC, !- Name IF VAV_bot_WITH_REHEAT_OA > VAV_bot_WITH_REHEAT_OA_VRP, !- Program Line 1 SET VAV_bot_WITH_REHEAT_MAX_OA_FRAC = NULL, !- Program Line 2 ELSE, !- A4 IF VAV_bot_SUPPLY_FLOW > 0, !- A5 SET VAV_bot_WITH_REHEAT_MAX_OA_FRAC = 2.0304 / VAV_bot_SUPPLY_FLOW,!- A6 ELSE, !- A7 SET VAV_bot_WITH_REHEAT_MAX_OA_FRAC = NULL, !- A8 ENDIF, !- A9 ENDIF; !- A10 EnergyManagementSystem:ProgramCallingManager, VAV_mid_WITH_REHEAT_MAX_OA_FRAC_Prog_Manager,!- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point VAV_mid_WITH_REHEAT_MAX_OA_FRAC; !- Program Name 1 EnergyManagementSystem:Program, VAV_mid_WITH_REHEAT_MAX_OA_FRAC, !- Name IF VAV_mid_WITH_REHEAT_OA > VAV_mid_WITH_REHEAT_OA_VRP, !- Program Line 1 SET VAV_mid_WITH_REHEAT_MAX_OA_FRAC = NULL, !- Program Line 2 ELSE, !- A4 IF VAV_mid_SUPPLY_FLOW > 0, !- A5 SET VAV_mid_WITH_REHEAT_MAX_OA_FRAC = 20.304 / VAV_mid_SUPPLY_FLOW,!- A6 ELSE, !- A7 SET VAV_mid_WITH_REHEAT_MAX_OA_FRAC = NULL, !- A8 ENDIF, !- A9 ENDIF; !- A10 EnergyManagementSystem:ProgramCallingManager, VAV_top_WITH_REHEAT_MAX_OA_FRAC_Prog_Manager,!- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point VAV_top_WITH_REHEAT_MAX_OA_FRAC; !- Program Name 1 EnergyManagementSystem:Program, VAV_top_WITH_REHEAT_MAX_OA_FRAC, !- Name IF VAV_top_WITH_REHEAT_OA > VAV_top_WITH_REHEAT_OA_VRP, !- Program Line 1 SET VAV_top_WITH_REHEAT_MAX_OA_FRAC = NULL, !- Program Line 2 ELSE, !- A4 IF VAV_top_SUPPLY_FLOW > 0, !- A5 SET VAV_top_WITH_REHEAT_MAX_OA_FRAC = 2.0304 / VAV_top_SUPPLY_FLOW,!- A6 ELSE, !- A7 SET VAV_top_WITH_REHEAT_MAX_OA_FRAC = NULL, !- A8 ENDIF, !- A9 ENDIF; !- A10 EnergyManagementSystem:GlobalVariable, DataCenter_PreheatDeltaT;!- Erl Variable 1 Name EnergyManagementSystem:OutputVariable, DataCenter_ExtraElecHeatC_Status, !- Name DataCenter_ExtraElecHeatC_Status, !- EMS Variable Name Averaged, !- Type of Data in Variable SystemTimeStep, !- Update Frequency , !- EMS Program or Subroutine Name ; !- Units EnergyManagementSystem:OutputVariable, DataCenter_ExtraWaterHeatC_Status, !- Name DataCenter_ExtraWaterHeatC_Status, !- EMS Variable Name Averaged, !- Type of Data in Variable SystemTimeStep, !- Update Frequency , !- EMS Program or Subroutine Name ; !- Units EnergyManagementSystem:OutputVariable, DataCenter_ExtraElecHeatC_SP, !- Name DataCenter_ExtraElecHeatC_SP, !- EMS Variable Name Averaged, !- Type of Data in Variable SystemTimeStep, !- Update Frequency , !- EMS Program or Subroutine Name ; !- Units EnergyManagementSystem:OutputVariable, DataCenter_ExtraWaterHeatC_SP, !- Name DataCenter_ExtraWaterHeatC_SP, !- EMS Variable Name Averaged, !- Type of Data in Variable SystemTimeStep, !- Update Frequency , !- EMS Program or Subroutine Name ; !- Units EnergyManagementSystem:OutputVariable, DataCenter_PreheatDeltaT,!- Name DataCenter_PreheatDeltaT,!- EMS Variable Name Averaged, !- Type of Data in Variable SystemTimeStep, !- Update Frequency , !- EMS Program or Subroutine Name ; !- Units !- =========== ALL OBJECTS IN CLASS: ENERGYMANAGEMENTSYSTEM:INTERNALVARIABLE =========== EnergyManagementSystem:InternalVariable, DataCenter_FanDesignMass,!- Name DataCenter Basement Supply Fan, !- Internal Data Index Key Name Fan Maximum Mass Flow Rate; !- Internal Data Type !- =========== ALL OBJECTS IN CLASS: REPORT VARIABLE =========== ! Output:Variable,*,Site Outdoor Air Drybulb Temperature,Hourly; ! Output:Variable,*,Site Outdoor Air Wetbulb Temperature,Hourly; ! Output:Variable,*,Heating Coil Heating Energy,hourly; !- HVAC Sum J ! the total amount of heat transfer taking place in the coil ! Output:Variable,*,Cooling Coil Total Cooling Energy,hourly; !- HVAC Sum J ! Energy removed from air loop by Cooling Coils. total amount of heat transfer taking place in the coil ! Output:Variable,*,Pump Mass Flow Rate,hourly; !- HVAC Average ! the water outlet mass flow rate ! Output:Variable,*,Fan Air Mass Flow Rate,hourly; !- HVAC Average ! the amount of outdoor air entering the zone ! Output:Variable,*,Air System Outdoor Air Mass Flow Rate,hourly; !- HVAC Average ! average outdoor air mass flow rate introduced by the outdoor air controller ! Output:Variable,*,Boiler Heating Energy,hourly; !- HVAC Sum J ! the heating output (load) of the boiler ! Output:Variable,*,Chiller Evaporator Cooling Energy,hourly; !- HVAC Sum J ! the evaporator heat transfer which is the cooling delivered by the chiller !! Heating coils named as XXX_EXTRAWATERHEATC are dummy heating coils to capture heat transfer from the preheating coil to the bypass air when the air handling units are in the cooling mode. !! Heating coils named as XXX_ EXTRAELECHEATC are dummy heating coils to capture heat transfer from the electric steam humidifier airstream in the air handling units. !! The modeling strategy is documented in Section 5.2.2.8 Addendum 90.1-2010as Humidification System Requirements in the “ANSI/ASHRAE/IES Standard 90.1-2013 Determination of Energy Savings: Quantitative Analysis" report. !! Additional output variables that can be useful to review the mechancial equipment load profiles ! Output:Variable,MinOA_MotorizedDamper_Sched,Schedule Value,Hourly; ! Output:Variable,SHWSys1,Plant Supply Side Heating Demand Rate,Hourly; ! Output:Variable,VAV_bot WITH REHEAT SUPPLY EQUIPMENT OUTLET NODE,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_mid WITH REHEAT SUPPLY EQUIPMENT OUTLET NODE,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_top WITH REHEAT SUPPLY EQUIPMENT OUTLET NODE,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_bot WITH REHEAT_OAINLET NODE,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_mid WITH REHEAT_OAINLET NODE,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_top WITH REHEAT_OAINLET NODE,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_bot WITH REHEAT Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,VAV_mid WITH REHEAT Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,VAV_top WITH REHEAT Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,VAV_bot WITH REHEAT Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,VAV_mid WITH REHEAT Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,VAV_top WITH REHEAT Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,*,Boiler Heating Rate,Hourly; ! Output:Variable,*,Chiller Evaporator Cooling Rate,Hourly; ! Output:Variable,*,Air System Cooling Coil Total Cooling Energy,Hourly; ! Output:Variable,*,Air System Heating Coil Total Heating Energy,Hourly; ! Output:Variable,VAV_bot WITH REHEAT Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,VAV_mid WITH REHEAT Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,VAV_top WITH REHEAT Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,VAV_bot WITH REHEAT Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,VAV_mid WITH REHEAT Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,VAV_top WITH REHEAT Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,VAV_bot WITH REHEAT Supply Equipment Inlet Node,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_mid WITH REHEAT Supply Equipment Inlet Node,System Node Standard Density Volume Flow Rate,Hourly; ! Output:Variable,VAV_top WITH REHEAT Supply Equipment Inlet Node,System Node Standard Density Volume Flow Rate,Hourly; ! ! Utility and Submeter ! ! Output:Meter,Electricity:Facility,Hourly; ! Output:Meter,Gas:Facility,Hourly; ! Output:Meter,InteriorLights:Electricity,Hourly; ! Output:Meter,ExteriorLights:Electricity,Hourly; ! Output:Meter,InteriorEquipment:Electricity,Hourly; ! Output:Meter,ExteriorEquipment:Electricity,Hourly; ! Output:Meter,Fans:Electricity,Hourly; ! Output:Meter,Pumps:Electricity,Hourly; ! Output:Meter,Heating:Electricity,Hourly; ! Output:Meter,Cooling:Electricity,Hourly; ! Output:Meter,HeatRejection:Electricity,Hourly; ! Output:Meter,Humidifier:Electricity,Hourly; ! Output:Meter,HeatRecovery:Electricity,Hourly; ! Output:Meter,DHW:Electricity,Hourly; ! Output:Meter,Cogeneration:Electricity,Hourly; ! Output:Meter,Refrigeration:Electricity,Hourly; ! Output:Meter,WaterSystems:Electricity,Hourly; ! ! Output:Meter,InteriorLights:Gas,Hourly; ! Output:Meter,ExteriorLights:Gas,Hourly; ! Output:Meter,InteriorEquipment:Gas,Hourly; ! Output:Meter,ExteriorEquipment:Gas,Hourly; ! Output:Meter,Fans:Gas,Hourly; ! Output:Meter,Pumps:Gas,Hourly; ! Output:Meter,Heating:Gas,Hourly; ! Output:Meter,Cooling:Gas,Hourly; ! Output:Meter,HeatRejection:Gas,Hourly; ! Output:Meter,Humidifier:Gas,Hourly; ! Output:Meter,HeatRecovery:Gas,Hourly; ! Output:Meter,DHW:Gas,Hourly; ! Output:Meter,Cogeneration:Gas,Hourly; ! Output:Meter,Refrigeration:Gas,Hourly; ! Output:Meter,WaterSystems:Gas,Hourly; !- =========== ALL OBJECTS IN CLASS: REPORT =========== Output:Surfaces:Drawing,DXF; Output:Surfaces:List,Details; Output:VariableDictionary,IDF; Output:Constructions,Constructions; !- =========== ALL OBJECTS IN CLASS: REPORT:TABLE:STYLE =========== OutputControl:Table:Style, CommaAndHTML; !- Column Separator !- =========== ALL OBJECTS IN CLASS: OUTPUTCONTROL:REPORTINGTOLERANCES =========== OutputControl:ReportingTolerances, 0.556, !- Tolerance for Time Heating Setpoint Not Met {deltaC} 0.556; !- Tolerance for Time Cooling Setpoint Not Met {deltaC} !- =========== ALL OBJECTS IN CLASS: REPORT:TABLE:PREDEFINED =========== Output:Table:SummaryReports, AllSummaryAndMonthly, !- Report 1 Name Standard62.1Summary; !- Report 2 Name !- =========== ALL OBJECTS IN CLASS: REPORT:TABLE:MONTHLY =========== Output:Meter:MeterFileOnly,InteriorLights:Electricity,Hourly; Output:Meter:MeterFileOnly,InteriorEquipment:Electricity,Hourly; Output:Table:Monthly, NameHolderMonthlySummary TaskPurpose ProgressIndicator, !- Name ProgressIndicator,ForDetermination2019, ... 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary CodeName ASHRAE901, !- Name ASHRAE901, ASHRAE1891, IECC, Title24, ORSC, IGCC, ... 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary CodeYear 2019, !- Name all years for ASHRAE90.1, IECC, ASHRAE189.1 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary CodeAmendment NoneAmend, !- Name StateAmend,EEM, NoneAmend for national or state without amendment 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary PrototypeName OfficeLarge, !- Name 16 Prototypes 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary TaskScope National, !- Name National, State, City 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary State National, !- Name National for national analysis, NewYork, Utah,... for state analysis, or city name for city analysis. Spell out the name of the state without space between words 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary ClimateZone 6A, !- Name 0-8 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary RepresentCity USA_MN_Rochester, !- Name representative city like Honolulu for national, for each state, for city analysis. this is not the city of the weather file. The weather city will be extracted from epw file 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 EnergyManagementSystem:Sensor, Facility_Int_LTG, !- Name , !- Output:Variable or Output:Meter Index Key Name InteriorLights:Electricity; !- Output:Variable or Output:Meter Name EnergyManagementSystem:GlobalVariable, Wired_LTG; !- Erl Variable 1 Name EnergyManagementSystem:Program, Transformer_Load_Prog, !- Name SET Wired_LTG = Facility_Int_LTG*0.0281; !- Program Line 1 EnergyManagementSystem:ProgramCallingManager, Transformer_Load_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point Transformer_Load_Prog; !- Program Name 1 EnergyManagementSystem:OutputVariable, Wired_LTG, !- Name Wired_LTG, !- EMS Variable Name Summed, !- Type of Data in Variable ZoneTimeStep, !- Update Frequency , !- EMS Program or Subroutine Name J; !- Units Meter:Custom, Wired_LTG_Electricity, !- Name Electricity, !- Fuel Type , !- Key Name 1 Wired_LTG; !- Output Variable or Meter Name 1 Meter:CustomDecrement, Wired_Int_EQUIP, !- Name Electricity, !- Fuel Type InteriorEquipment:Electricity, !- Source Meter Name , !- Key Name 1 DataCenterPlugLoads:InteriorEquipment:Electricity; !- Output Variable or Meter Name 1 ElectricLoadCenter:Transformer, Transformer 1, !- Name Always_On, !- Availability Schedule Name PowerInFromGrid, !- Transformer Usage , !- Zone Name , !- Radiative Fraction 500000, !- Rated Capacity {VA} 3, !- Phase Aluminum, !- Conductor Material 150, !- Full Load Temperature Rise {C} 0.1, !- Fraction of Eddy Current Losses NominalEfficiency, !- Performance Input Method , !- Rated No Load Loss {W} , !- Rated Load Loss {W} 0.991, !- Nameplate Efficiency 0.35, !- Per Unit Load for Nameplate Efficiency 75, !- Reference Temperature for Nameplate Efficiency {C} , !- Per Unit Load for Maximum Efficiency Yes, !- Consider Transformer Loss for Utility Cost Wired_LTG_Electricity, !- Meter 1 Name Wired_Int_EQUIP; !- Meter 2 Name EnergyManagementSystem:Sensor, Tower_PumpMassFlow, !- Name TowerWaterSys Supply Inlet Node, !- Output:Variable or Output:Meter Index Key Name System Node Mass Flow Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Chiller1_Status, !- Name CoolSys1 Chiller1, !- Output:Variable or Output:Meter Index Key Name Chiller Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Chiller2_Status, !- Name CoolSys1 Chiller2, !- Output:Variable or Output:Meter Index Key Name Chiller Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, SensedCurveInput, !- Name Tower_Fan_Curve, !- Output:Variable or Output:Meter Index Key Name Performance Curve Input Variable 1 Value; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, SensedCurveValue, !- Name Tower_Fan_Curve, !- Output:Variable or Output:Meter Index Key Name Performance Curve Output Value; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Actuator, TowerCurveOutput, !- Name Tower_Fan_Curve, !- Actuated Component Unique Name Curve, !- Actuated Component Type Curve Result; !- Actuated Component Control Type EnergyManagementSystem:Program, ChangTowerFlow, !- Name IF Chiller1_Status > 0 && Chiller2_Status == 0 && SensedCurveInput > 0.2, !- Program Line 1 IF (0.5 * SensedCurveInput) > 0.2, !- Program Line 2 SET AirInput = 0.5 * SensedCurveInput, !- ELSE, !- SET AirInput = 0.2, !- ENDIF, !- SET TowerCurveOutput = 2* (AirInput^3), !- ELSE, !- SET TowerCurveOutput = SensedCurveValue, !- ENDIF; !- EnergyManagementSystem:ProgramCallingManager, ChangeTowerFlow_Manager, !- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point ChangTowerFlow; !- Program Name 1 EnergyManagementSystem:GlobalVariable, BoilerType, !- Erl Variable 1 Name CapRated, !- Erl Variable 2 Name EtRated, !- Erl Variable 3 Name PLRx, !- Ecx, !- SkinLossRate; !- EnergyManagementSystem:Sensor, BoilerPLR, !- Name HeatSys1 Boiler, !- Output:Variable or Output:Meter Index Key Name Boiler Part Load Ratio; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Actuator, BoilerCurve, !- Name HEATSYS1 BOILER EFFICIENCY CURVE, !- Actuated Component Unique Name Curve, !- Actuated Component Type Curve Result; !- Actuated Component Control Type EnergyManagementSystem:Program, ! Addendum AM SetBoilerPar, SET CapRated = 1953430.325, ! EMS Bolier Nominal Capacity {W}. SET EtRated = 0.8125, ! EMS Boiler Nominal Thermal Efficiency. overriden by script SET CapRated = (CapRated *3.412)/1000, !Change from W to MBH SET SkinLossRate = 0.02, SET BoilerType = 1, IF BoilerType == 1, IF CapRated >10000, SET PLRx = 0.2, ELSEIF CapRated >5000, SET PLRx = 0.25, ELSEIF CapRated >1000, SET PLRx = 0.33, ELSE, SET BoilerType = 2, SET PLRx = 0.2, ENDIF, ELSE, SET PLRx = 0.2, ENDIF, IF BoilerType == 1, SET CurveX = 0.975 + 0.305 * PLRx - 0.527 * (PLRx^2) + 0.249 * (PLRx^3), ELSE, SET CurveX = 0.907 + 0.320 * PLRx - 0.420 * (PLRx^2) + 0.193 * (PLRx^3), ENDIF, SET LoadX = CapRated * PLRx, SET Etx = CurveX * EtRated, SET InputEx = LoadX/Etx, SET SkinEx = CapRated * SkinLossRate, SET Ecx = (LoadX + SkinEx)/InputEx; EnergyManagementSystem:Program, SetBoilerCurve, !- Name IF BoilerPLR >= PLRx, !- Program Line 1 IF BoilerType == 1, !- Program Line 2 SET BoilerCurve = 0.975 + 0.305*BoilerPLR - 0.527*(BoilerPLR^2) + 0.249*(BoilerPLR^3), !- ELSE, !- SET BoilerCurve = 0.907 + 0.320*BoilerPLR - 0.420*(BoilerPLR^2) + 0.193*(BoilerPLR^3), !- ENDIF, !- ELSE, !- IF BoilerPLR == 0, !- SET BoilerCurve = NULL, !- ELSE, !- IF BoilerPLR <0.05, !- SET BoilerCurve = (0.05/(0.05 + SkinLossRate)) * (Ecx/EtRated), !- ELSE, !- SET BoilerCurve = (BoilerPLR/(BoilerPLR + SkinLossRate)) * (Ecx/EtRated), !- ENDIF, !- ENDIF, !- ENDIF; !- EnergyManagementSystem:ProgramCallingManager, BoilerParManager, !- Name BeginNewEnvironment, !- EnergyPlus Model Calling Point SetBoilerPar; !- Program Name 1 EnergyManagementSystem:ProgramCallingManager, BoilerCurveManager, !- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point SetBoilerCurve; !- Program Name 1 EnergyManagementSystem:Sensor, OAT, !- Name Environment, !- Output:Variable or Output:Meter Index Key Name Site Outdoor Air Drybulb Temperature; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Actuator, CLGSETP_SCH_Actuator, !- Name CLGSETP_SCH_Yes_Optimum, !- Actuated Component Unique Name Schedule:Compact, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, CLGSETP_SCH_w_SB_Actuator, !- Name CLGSETP_SCH_Yes_Optimum_w_SB, !- Actuated Component Unique Name Schedule:Compact, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, HTGSETP_SCH_Actuator, !- Name HTGSETP_SCH_Yes_Optimum, !- Actuated Component Unique Name Schedule:Compact, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:Actuator, HTGSETP_SCH_w_SB_Actuator, !- Name HTGSETP_SCH_Yes_Optimum_w_SB, !- Actuated Component Unique Name Schedule:Compact, !- Actuated Component Type Schedule Value; !- Actuated Component Control Type EnergyManagementSystem:ProgramCallingManager, OA_BASED_OPTIMUM_START_EMS_Program Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point OA_BASED_OPTIMUM_START_EMS_Program; !- Program Name 1 EnergyManagementSystem:Program, OA_BASED_OPTIMUM_START_EMS_Program, !- Name IF DaylightSavings==0 && DayOfWeek>1 && Hour==4 && OAT<23.9 && OAT>1.7, !- Program Line 1 SET CLGSETP_SCH_Actuator = 26.7, !- Program Line 2 SET HTGSETP_SCH_Actuator = 15.6, !- SET CLGSETP_SCH_w_SB_Actuator = 26.7, !- SET HTGSETP_SCH_w_SB_Actuator = 15.6, !- ELSEIF DaylightSavings==1 && DayOfWeek>1 && Hour==3 && OAT<23.9 && OAT>1.7, !- SET CLGSETP_SCH_Actuator = 26.7, !- SET HTGSETP_SCH_Actuator = 15.6, !- SET CLGSETP_SCH_w_SB_Actuator = 26.7, !- SET HTGSETP_SCH_w_SB_Actuator = 15.6, !- ELSE, !- SET CLGSETP_SCH_Actuator = NULL, !- SET HTGSETP_SCH_Actuator = NULL, !- SET CLGSETP_SCH_w_SB_Actuator = NULL, !- SET HTGSETP_SCH_w_SB_Actuator = NULL, !- ENDIF; !- EnergyManagementSystem:InternalVariable, Chiller2PumpDesignFlow, !- Name COOLSYS1 CHILLER2 PUMP, !- Internal Data Index Key Name Pump Maximum Mass Flow Rate; !- Internal Data Type EnergyManagementSystem:Actuator, Chiller2PumpStatus, !- Name COOLSYS1 CHILLER2 PUMP, !- Actuated Component Unique Name Plant Component Pump:ConstantSpeed, !- Actuated Component Type On/Off Supervisory; !- Actuated Component Control Type EnergyManagementSystem:Actuator, Chiller1PumpFlow, !- Name COOLSYS1 CHILLER1 PUMP, !- Actuated Component Unique Name Pump, !- Actuated Component Type Pump Mass Flow Rate; !- Actuated Component Control Type EnergyManagementSystem:Actuator, Chiller2PumpFlow, !- Name COOLSYS1 CHILLER2 PUMP, !- Actuated Component Unique Name Pump, !- Actuated Component Type Pump Mass Flow Rate; !- Actuated Component Control Type EnergyManagementSystem:Actuator, Chiller2Status, !- Name COOLSYS1 CHILLER2, !- Actuated Component Unique Name Plant Component Chiller:Electric:ReformulatedEIR, !- Actuated Component Type On/Off Supervisory; !- Actuated Component Control Type EnergyManagementSystem:Sensor, ChillerPlantDemandLoad, !- Name CoolSys1_Supply, !- Output:Variable or Output:Meter Index Key Name Plant Supply Side Cooling Demand Rate; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Program, ! Addendum DV PlantPump_EMS_Program, ! IF ChillerPlantDemandLoad < 1302254.38, ! Addendum DV EMS Chiller Capacity. Will be overriden by sizing script. SET Chiller2PumpStatus = 0, !- SET Chiller2Status = 0, !- SET Chiller2PumpFlow = 0,!- ELSE, !- SET Chiller2PumpStatus = 1, !- SET Chiller2Status = 1, !- SET Chiller2PumpFlow = Chiller2PumpDesignFlow, !- ENDIF; !- EnergyManagementSystem:ProgramCallingManager, PlantPump_EMS_Program Manager, !- Name InsideHVACSystemIterationLoop, !- EnergyPlus Model Calling Point PlantPump_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Basement_LSr, !- Name Basement, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Basement_Occ_Sensor, !- Name Basement, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Basement_Area, !- Name Basement, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Basement_Light_Actuator, !- Name Basement_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Basement_Light_EMS_Program, !- Name SET Basement_LSr_IP=0.093*Basement_LSr/Basement_Area, ! Calculate the actual LPD for each hour IF (Basement_Occ_Sensor <= 0) && (Basement_LSr_IP >= 0.02), SET Basement_Light_Actuator = 0.02*Basement_Area/0.09290304, ELSE, SET Basement_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Basement_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Basement_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Core_bottom_LSr, !- Name Core_bottom, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Core_bottom_Occ_Sensor, !- Name Core_bottom, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Core_bottom_Area, !- Name Core_bottom, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Core_bottom_Light_Actuator, !- Name Core_bottom_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Core_bottom_Light_EMS_Program, !- Name SET Core_bottom_LSr_IP=0.093*Core_bottom_LSr/Core_bottom_Area, ! Calculate the actual LPD for each hour IF (Core_bottom_Occ_Sensor <= 0) && (Core_bottom_LSr_IP >= 0.02), SET Core_bottom_Light_Actuator = 0.02*Core_bottom_Area/0.09290304, ELSE, SET Core_bottom_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Core_bottom_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Core_bottom_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Core_mid_LSr, !- Name Core_mid, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Core_mid_Occ_Sensor, !- Name Core_mid, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Core_mid_Area, !- Name Core_mid, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Core_mid_Light_Actuator, !- Name Core_mid_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Core_mid_Light_EMS_Program, !- Name SET Core_mid_LSr_IP=0.093*Core_mid_LSr/Core_mid_Area, ! Calculate the actual LPD for each hour IF (Core_mid_Occ_Sensor <= 0) && (Core_mid_LSr_IP >= 0.02), SET Core_mid_Light_Actuator = 0.02*Core_mid_Area/0.09290304, ELSE, SET Core_mid_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Core_mid_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Core_mid_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Core_top_LSr, !- Name Core_top, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Core_top_Occ_Sensor, !- Name Core_top, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Core_top_Area, !- Name Core_top, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Core_top_Light_Actuator, !- Name Core_top_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Core_top_Light_EMS_Program, !- Name SET Core_top_LSr_IP=0.093*Core_top_LSr/Core_top_Area, ! Calculate the actual LPD for each hour IF (Core_top_Occ_Sensor <= 0) && (Core_top_LSr_IP >= 0.02), SET Core_top_Light_Actuator = 0.02*Core_top_Area/0.09290304, ELSE, SET Core_top_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Core_top_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Core_top_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_bot_ZN_3_LSr, !- Name Perimeter_bot_ZN_3, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_bot_ZN_3_Occ_Sensor, !- Name Perimeter_bot_ZN_3, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_bot_ZN_3_Area, !- Name Perimeter_bot_ZN_3, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_bot_ZN_3_Light_Actuator, !- Name Perimeter_bot_ZN_3_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_bot_ZN_3_Light_EMS_Program, !- Name SET Perimeter_bot_ZN_3_LSr_IP=0.093*Perimeter_bot_ZN_3_LSr/Perimeter_bot_ZN_3_Area, ! Calculate the actual LPD for each hour IF (Perimeter_bot_ZN_3_Occ_Sensor <= 0) && (Perimeter_bot_ZN_3_LSr_IP >= 0.02), SET Perimeter_bot_ZN_3_Light_Actuator = 0.02*Perimeter_bot_ZN_3_Area/0.09290304, ELSE, SET Perimeter_bot_ZN_3_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_bot_ZN_3_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_bot_ZN_3_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_bot_ZN_2_LSr, !- Name Perimeter_bot_ZN_2, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_bot_ZN_2_Occ_Sensor, !- Name Perimeter_bot_ZN_2, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_bot_ZN_2_Area, !- Name Perimeter_bot_ZN_2, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_bot_ZN_2_Light_Actuator, !- Name Perimeter_bot_ZN_2_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_bot_ZN_2_Light_EMS_Program, !- Name SET Perimeter_bot_ZN_2_LSr_IP=0.093*Perimeter_bot_ZN_2_LSr/Perimeter_bot_ZN_2_Area, ! Calculate the actual LPD for each hour IF (Perimeter_bot_ZN_2_Occ_Sensor <= 0) && (Perimeter_bot_ZN_2_LSr_IP >= 0.02), SET Perimeter_bot_ZN_2_Light_Actuator = 0.02*Perimeter_bot_ZN_2_Area/0.09290304, ELSE, SET Perimeter_bot_ZN_2_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_bot_ZN_2_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_bot_ZN_2_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_bot_ZN_1_LSr, !- Name Perimeter_bot_ZN_1, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_bot_ZN_1_Occ_Sensor, !- Name Perimeter_bot_ZN_1, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_bot_ZN_1_Area, !- Name Perimeter_bot_ZN_1, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_bot_ZN_1_Light_Actuator, !- Name Perimeter_bot_ZN_1_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_bot_ZN_1_Light_EMS_Program, !- Name SET Perimeter_bot_ZN_1_LSr_IP=0.093*Perimeter_bot_ZN_1_LSr/Perimeter_bot_ZN_1_Area, ! Calculate the actual LPD for each hour IF (Perimeter_bot_ZN_1_Occ_Sensor <= 0) && (Perimeter_bot_ZN_1_LSr_IP >= 0.02), SET Perimeter_bot_ZN_1_Light_Actuator = 0.02*Perimeter_bot_ZN_1_Area/0.09290304, ELSE, SET Perimeter_bot_ZN_1_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_bot_ZN_1_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_bot_ZN_1_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_bot_ZN_4_LSr, !- Name Perimeter_bot_ZN_4, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_bot_ZN_4_Occ_Sensor, !- Name Perimeter_bot_ZN_4, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_bot_ZN_4_Area, !- Name Perimeter_bot_ZN_4, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_bot_ZN_4_Light_Actuator, !- Name Perimeter_bot_ZN_4_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_bot_ZN_4_Light_EMS_Program, !- Name SET Perimeter_bot_ZN_4_LSr_IP=0.093*Perimeter_bot_ZN_4_LSr/Perimeter_bot_ZN_4_Area, ! Calculate the actual LPD for each hour IF (Perimeter_bot_ZN_4_Occ_Sensor <= 0) && (Perimeter_bot_ZN_4_LSr_IP >= 0.02), SET Perimeter_bot_ZN_4_Light_Actuator = 0.02*Perimeter_bot_ZN_4_Area/0.09290304, ELSE, SET Perimeter_bot_ZN_4_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_bot_ZN_4_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_bot_ZN_4_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_mid_ZN_3_LSr, !- Name Perimeter_mid_ZN_3, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_mid_ZN_3_Occ_Sensor, !- Name Perimeter_mid_ZN_3, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_mid_ZN_3_Area, !- Name Perimeter_mid_ZN_3, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_mid_ZN_3_Light_Actuator, !- Name Perimeter_mid_ZN_3_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_mid_ZN_3_Light_EMS_Program, !- Name SET Perimeter_mid_ZN_3_LSr_IP=0.093*Perimeter_mid_ZN_3_LSr/Perimeter_mid_ZN_3_Area, ! Calculate the actual LPD for each hour IF (Perimeter_mid_ZN_3_Occ_Sensor <= 0) && (Perimeter_mid_ZN_3_LSr_IP >= 0.02), SET Perimeter_mid_ZN_3_Light_Actuator = 0.02*Perimeter_mid_ZN_3_Area/0.09290304, ELSE, SET Perimeter_mid_ZN_3_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_mid_ZN_3_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_mid_ZN_3_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_mid_ZN_2_LSr, !- Name Perimeter_mid_ZN_2, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_mid_ZN_2_Occ_Sensor, !- Name Perimeter_mid_ZN_2, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_mid_ZN_2_Area, !- Name Perimeter_mid_ZN_2, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_mid_ZN_2_Light_Actuator, !- Name Perimeter_mid_ZN_2_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_mid_ZN_2_Light_EMS_Program, !- Name SET Perimeter_mid_ZN_2_LSr_IP=0.093*Perimeter_mid_ZN_2_LSr/Perimeter_mid_ZN_2_Area, ! Calculate the actual LPD for each hour IF (Perimeter_mid_ZN_2_Occ_Sensor <= 0) && (Perimeter_mid_ZN_2_LSr_IP >= 0.02), IF (DaylightSavings==0) && ((Hour < 7) || (Hour > 16)), !- Hour check is to avoid conflict with Add. G SET Perimeter_mid_ZN_2_Light_Actuator = 0.02*Perimeter_mid_ZN_2_Area/0.09290304, ELSEIF (DaylightSavings==1) && ((Hour < 6) || (Hour > 15)), !- Hour check is to avoid conflict with Add. G 1 SET Perimeter_mid_ZN_2_Light_Actuator = 0.02*Perimeter_mid_ZN_2_Area/0.09290304, ELSE, SET Perimeter_mid_ZN_2_Light_Actuator = NULL, ENDIF, ELSE, SET Perimeter_mid_ZN_2_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_mid_ZN_2_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_mid_ZN_2_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_mid_ZN_1_LSr, !- Name Perimeter_mid_ZN_1, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_mid_ZN_1_Occ_Sensor, !- Name Perimeter_mid_ZN_1, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_mid_ZN_1_Area, !- Name Perimeter_mid_ZN_1, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_mid_ZN_1_Light_Actuator, !- Name Perimeter_mid_ZN_1_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_mid_ZN_1_Light_EMS_Program, !- Name SET Perimeter_mid_ZN_1_LSr_IP=0.093*Perimeter_mid_ZN_1_LSr/Perimeter_mid_ZN_1_Area, ! Calculate the actual LPD for each hour IF (Perimeter_mid_ZN_1_Occ_Sensor <= 0) && (Perimeter_mid_ZN_1_LSr_IP >= 0.02), SET Perimeter_mid_ZN_1_Light_Actuator = 0.02*Perimeter_mid_ZN_1_Area/0.09290304, ELSE, SET Perimeter_mid_ZN_1_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_mid_ZN_1_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_mid_ZN_1_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_mid_ZN_4_LSr, !- Name Perimeter_mid_ZN_4, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_mid_ZN_4_Occ_Sensor, !- Name Perimeter_mid_ZN_4, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_mid_ZN_4_Area, !- Name Perimeter_mid_ZN_4, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_mid_ZN_4_Light_Actuator, !- Name Perimeter_mid_ZN_4_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_mid_ZN_4_Light_EMS_Program, !- Name SET Perimeter_mid_ZN_4_LSr_IP=0.093*Perimeter_mid_ZN_4_LSr/Perimeter_mid_ZN_4_Area, ! Calculate the actual LPD for each hour IF (Perimeter_mid_ZN_4_Occ_Sensor <= 0) && (Perimeter_mid_ZN_4_LSr_IP >= 0.02), SET Perimeter_mid_ZN_4_Light_Actuator = 0.02*Perimeter_mid_ZN_4_Area/0.09290304, ELSE, SET Perimeter_mid_ZN_4_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_mid_ZN_4_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_mid_ZN_4_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_top_ZN_3_LSr, !- Name Perimeter_top_ZN_3, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_top_ZN_3_Occ_Sensor, !- Name Perimeter_top_ZN_3, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_top_ZN_3_Area, !- Name Perimeter_top_ZN_3, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_top_ZN_3_Light_Actuator, !- Name Perimeter_top_ZN_3_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_top_ZN_3_Light_EMS_Program, !- Name SET Perimeter_top_ZN_3_LSr_IP=0.093*Perimeter_top_ZN_3_LSr/Perimeter_top_ZN_3_Area, ! Calculate the actual LPD for each hour IF (Perimeter_top_ZN_3_Occ_Sensor <= 0) && (Perimeter_top_ZN_3_LSr_IP >= 0.02), SET Perimeter_top_ZN_3_Light_Actuator = 0.02*Perimeter_top_ZN_3_Area/0.09290304, ELSE, SET Perimeter_top_ZN_3_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_top_ZN_3_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_top_ZN_3_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_top_ZN_2_LSr, !- Name Perimeter_top_ZN_2, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_top_ZN_2_Occ_Sensor, !- Name Perimeter_top_ZN_2, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_top_ZN_2_Area, !- Name Perimeter_top_ZN_2, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_top_ZN_2_Light_Actuator, !- Name Perimeter_top_ZN_2_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_top_ZN_2_Light_EMS_Program, !- Name SET Perimeter_top_ZN_2_LSr_IP=0.093*Perimeter_top_ZN_2_LSr/Perimeter_top_ZN_2_Area, ! Calculate the actual LPD for each hour IF (Perimeter_top_ZN_2_Occ_Sensor <= 0) && (Perimeter_top_ZN_2_LSr_IP >= 0.02), SET Perimeter_top_ZN_2_Light_Actuator = 0.02*Perimeter_top_ZN_2_Area/0.09290304, ELSE, SET Perimeter_top_ZN_2_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_top_ZN_2_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_top_ZN_2_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_top_ZN_1_LSr, !- Name Perimeter_top_ZN_1, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_top_ZN_1_Occ_Sensor, !- Name Perimeter_top_ZN_1, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_top_ZN_1_Area, !- Name Perimeter_top_ZN_1, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_top_ZN_1_Light_Actuator, !- Name Perimeter_top_ZN_1_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_top_ZN_1_Light_EMS_Program, !- Name SET Perimeter_top_ZN_1_LSr_IP=0.093*Perimeter_top_ZN_1_LSr/Perimeter_top_ZN_1_Area, ! Calculate the actual LPD for each hour IF (Perimeter_top_ZN_1_Occ_Sensor <= 0) && (Perimeter_top_ZN_1_LSr_IP >= 0.02), SET Perimeter_top_ZN_1_Light_Actuator = 0.02*Perimeter_top_ZN_1_Area/0.09290304, ELSE, SET Perimeter_top_ZN_1_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_top_ZN_1_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_top_ZN_1_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_top_ZN_4_LSr, !- Name Perimeter_top_ZN_4, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_top_ZN_4_Occ_Sensor, !- Name Perimeter_top_ZN_4, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_top_ZN_4_Area, !- Name Perimeter_top_ZN_4, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_top_ZN_4_Light_Actuator, !- Name Perimeter_top_ZN_4_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_top_ZN_4_Light_EMS_Program, !- Name SET Perimeter_top_ZN_4_LSr_IP=0.093*Perimeter_top_ZN_4_LSr/Perimeter_top_ZN_4_Area, ! Calculate the actual LPD for each hour IF (Perimeter_top_ZN_4_Occ_Sensor <= 0) && (Perimeter_top_ZN_4_LSr_IP >= 0.02), SET Perimeter_top_ZN_4_Light_Actuator = 0.02*Perimeter_top_ZN_4_Area/0.09290304, ELSE, SET Perimeter_top_ZN_4_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_top_ZN_4_Light_EMS_Program_Prog_Manager, !- Name AfterPredictorAfterHVACManagers, !- EnergyPlus Model Calling Point SET_Perimeter_top_ZN_4_Light_EMS_Program; !- Program Name 1 HeatExchanger:FluidToFluid, Bypass Heat exchanger, !- Name ALWAYS_ON, !- Availability Schedule Name CoolSys1 Exchancher Supply Inlet Node, !- Loop Demand Side Inlet Node Name CoolSys1 Exchancher Supply Outlet Node, !- Loop Demand Side Outlet Node Name autosize, !- Loop Demand Side Design Flow Rate {m3/s} CoolSys1 Exchancher Demand Inlet Node, !- Loop Supply Side Inlet Node Name CoolSys1 Exchancher Demand Outlet Node, !- Loop Supply Side Outlet Node Name autosize, !- Loop Supply Side Design Flow Rate {m3/s} Ideal, !- Heat Exchange Model Type autosize, !- Heat Exchanger U-Factor Times Area Value {W/K} UncontrolledOn, !- Control Type , !- Heat Exchanger Setpoint Node Name 0.01, !- Minimum Temperature Difference to Activate Heat Exchanger {deltaC} LoopToLoop, !- Heat Transfer Metering End Use Type , !- Component Override Loop Supply Side Inlet Node Name , !- Component Override Loop Demand Side Inlet Node Name Loop, !- Component Override Cooling Control Temperature Mode 1; !- Sizing Factor