!The DOE Prototype Building Models were developed by Pacific Northwest National Laboratory (PNNL), under contract with the U.S. !Department of Energy (DOE). These building models were derived from DOE's Commercial Reference Building Models with modifications !based on input from the ASHRAE Standard 90.1 committee, the Advanced Energy Design Guide series, and building industry experts. The !prototypes models were developed to quantify energy saving impacts from newly published editions of ASHRAE Standard 90.1, 189.1, IECC, !and other energy codes and standards. The basic building descriptions can be found in the Scorecards posted at www.energycodes.gov !website. The recommended citation of the prototype models is ! !DOE and PNNL. 2020. Commercial Prototype Building Models, Richland, WA, Pacific Northwest National Laboratory. Available at https://www.energycodes.gov/development/commercial/prototype_models. ! !Detailed descriptions of the prototype model development and addenda modeling strategies can be found in the following reports: !DOE, 2020. Preliminary Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2019. Report prepared by Zhang, J., M. Rosenberg, J. !Lerond, Y. Xie, Nambia, C., Y. Chen, R. Hart, M. Halverson, D. Maddox, and S. Goel, Richland, WA, Pacific Northwest National Laboratory. ! !Zhang, J., Y. Chen, Y. Xie, M. Rosenberg, R. Hart. Energy and Energy Cost Savings Analysis of the 2018 IECC for Commercial Buildings. !2018. PNNL-28125. Richland, WA: Pacific Northwest National Laboratory. ! !DOE. 2017. Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016. Prepared by Athalye, R.A, M.A. Halverson, M.I. Rosenberg, B. Liu, !J. Zhang, R. Hart, V.V. Mendon, S. Goel, Y. Chen, Y. Xie, and M. Zhao, Richland, WA, Pacific Northwest National Laboratory. https://www.energycodes.gov/sites/default/files/documents/02202018_Standard_90.1-2016_Determination_TSD.pdf. ! !Zhang, J., Y. Xie, R.A. Athalye, J. Zhuge, M. Rosenberg, R. Hart, and B. Liu. Energy and Energy Cost Savings Analysis of the 2015 IECC !for Commercial Buildings. 2015. PNNL-24269 Rev. 1. Richland, WA: Pacific Northwest National !Laboratory. https://www.energycodes.gov/sites/default/files/documents/2015_IECC_Commercial_Analysis.pdf. ! !Halverson M.A., M.I. Rosenberg, W. Wang, J. Zhang, V.V. Mendon, R.A. Athalye, Y. Xie, R. Hart, S. Goel, 2014. ANSI/ASHRAE/IES Standard !90.1-2013 Determination of Energy Savings: Quantitative Analysis, PNNL-23479. Richland, WA: Pacific Northwest National Laboratory. https://www.energycodes.gov/sites/default/files/documents/901-2013_finalCommercialDeterminationQuantitativeAnalysis_TSD_0.pdf. ! !Goel S., R.A. Athalye, W. Wang, J. Zhang, M.I. Rosenberg, Y. Xie, and R. Hart, et al. 2014. Enhancements to ASHRAE Standard 90.1 !Prototype Building Models. PNNL-23269. Richland, WA: Pacific Northwest National Laboratory. https://www.pnnl.gov/main/publications/external/technical_reports/PNNL-23269.pdf. ! !Zhang J., R.A. Athalye, R. Hart, M.I. Rosenberg, Y. Xie, S. Goel, and V.V. Mendon, et al. 2013. Energy and Energy Cost Savings Analysis !of the IECC for Commercial Buildings. PNNL-22760. Richland, WA: Pacific Northwest National Laboratory. http://www.pnnl.gov/main/publications/external/technical_reports/PNNL-22760.pdf. ! !Thornton B.A., M.I. Rosenberg, E.E. Richman, W. Wang, Y. Xie, J. Zhang, H. Cho, VV Mendon, R.A. Athalye, and B. Liu. 2011. Achieving !the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010. PNNL-20405. Richland, WA: Pacific Northwest National !Laboratory. https://www.energycodes.gov/sites/default/files/documents/BECP_Energy_Cost_Savings_STD2010_May2011_v00.pdf. ! ! ! WeatherFile: USA_MN_Rochester.Intl.AP.726440_TMY3.epw ! BEGIN ECONOMIZER MAP ! Economizer Name, DX COIL Name ! PSZ-AC:1_OA_Controller, PSZ-AC:1 Heat Pump DX Cooling Coil ! PSZ-AC:2_OA_Controller, PSZ-AC:2 Heat Pump DX Cooling Coil ! PSZ-AC:3_OA_Controller, PSZ-AC:3 Heat Pump DX Cooling Coil ! PSZ-AC:4_OA_Controller, PSZ-AC:4 Heat Pump DX Cooling Coil ! PSZ-AC:5_OA_Controller, PSZ-AC:5 Heat Pump DX Cooling Coil ! END ECONOMIZER MAP ! GPARM parameters as input: ! Case = ASHRAE901_OfficeSmall_STD2019_Rochester ! SelectedCase = ! annual_run = yes ! slab_gtp = National_OfficeSmall_ASHRAE901_STD2016_Zone6A_nonres_MN-Rochester-MN.gtp ! basement_tempt = dummy.idf ! avg_oa_tempt_ip = 43.475 ! maxdiff_oa_tempt_ip = 60.3 ! ext_wall_type = WoodFramedWall ! nonres_ext_wall_ufactor = 0.289591413 ! roof_type = WoodJoistAtticRoof ! nonres_roof_ufactor = 0.119243523 ! roof_solar_absorp = 0.7 ! nonres_window = ! sidelighting_control = yes_AY ! economizer = DifferentialDryBulb ! skip_economizer_control = No ! LPD_office = 6.888902667 ! exterior_lights_watts = 0 ! exterior_lights_watts_a = 50.7 ! exterior_lights_watts_b = 115.1 ! avg_oa_tempt = 6.375 ! maxdiff_oa_tempt = 33.5 ! infil = 0.00056896 ! oa_flow_per_area = 0.000431773 ! door_infil = 0.076455414 ! frac_ofpk = 0.131 ! damper_sch = MinOA_MotorizedDamper_Sched ! economizer_lockout = LockoutWithHeating ! BLDG_EQUIP_SCH = BLDG_EQUIP_SCH_ADV ! addendum_cd = 2016AS ! pv_generator = no ! pv_surface_area = 0 ! STD189_overhang = no ! swh_et = 1 ! swh_ua = 1.205980747 ! ext_lgt_sch = Exterior_Lgt_ALWAYS_ON ! LTG_SCH_SET = LTG_SET_STD2013 ! HtgSetP_Sch = HTGSETP_SCH_NO_OPTIMUM ! CLGSETP_SCH = CLGSETP_SCH_NO_OPTIMUM ! pipe_heat_loss = 571 ! skip_EMSprogram = yes ! Wfile_TMY3 = USA_MN_Rochester.Intl.AP.726440_TMY3.epw ! loadProfile = No ! receptacle_ctrl_occ_reduction_frac = 0.959505267 ! receptacle_ctrl_unocc_reduction_frac = 0.818955113 ! CodeName = ASHRAE90.1_STD2019 ! CZ_City_Old = Burlington ! CZ_Label = 6A ! exterior_lights_watts_c = 445.5 ! Addendum_AH = Yes ! LPD_Ctrl = 0.02 ! con_swingdoor_r = 0.475963827 ! office_standby_mode = Yes ! nonres_window_u_factor = 0.34 ! nonres_window_shgc = 0.38 ! nonresLSG = 1.1 ! AnalysisPurpose = ProgressIndicator ! AnalysisCodeName = ASHRAE901 ! AnalysisCodeYear = 2019 ! AnalysisAmendment = NoneAmend ! AnalysisPrototype = OfficeSmall ! AnalysisScope = National ! AnalysisState = National ! AnalysisClimateZone = 6A ! AnalysisCity = USA_MN_Rochester ! var_Ffactor_IP = 0.51 ! var_Cfactor_IP = 0.092 ! Core_ZN_SWH_flow = 4.048e-06 ! VT_Elec_Wheater = No ! specify overhang_pf for 1891 codes Version,9.0; !- =========== ALL OBJECTS IN CLASS: SIMULATIONCONTROL =========== SimulationControl, Yes, !- Do Zone Sizing Calculation Yes, !- Do System Sizing Calculation Yes, !- Do Plant Sizing Calculation No, !- Run Simulation for Sizing Periods YES; !- Run Simulation for Weather File Run Periods !- =========== ALL OBJECTS IN CLASS: BUILDING =========== Building, OfficeSmall, !- Name 0.0000, !- North Axis {deg} City, !- Terrain 0.0400, !- Loads Convergence Tolerance Value 0.2000, !- Temperature Convergence Tolerance Value {deltaC} FullInteriorAndExterior, !- Solar Distribution 25, !- Maximum Number of Warmup Days 6; !- Minimum Number of Warmup Days !- =========== ALL OBJECTS IN CLASS: SHADOWCALCULATION =========== ShadowCalculation, AverageOverDaysInFrequency, !- Calculation Method 30, !- Calculation Frequency 15000; !- Maximum Figures in Shadow Overlap Calculations !- =========== ALL OBJECTS IN CLASS: SURFACECONVECTIONALGORITHM:INSIDE =========== SurfaceConvectionAlgorithm:Inside,TARP; !- =========== ALL OBJECTS IN CLASS: SURFACECONVECTIONALGORITHM:OUTSIDE =========== SurfaceConvectionAlgorithm:Outside,TARP; !- =========== ALL OBJECTS IN CLASS: HEATBALANCEALGORITHM =========== HeatBalanceAlgorithm,ConductionTransferFunction,200.0000; !- =========== ALL OBJECTS IN CLASS: TIMESTEP =========== Timestep,6; !- =========== ALL OBJECTS IN CLASS: CONVERGENCELIMITS =========== ConvergenceLimits, 1, !- Minimum System Timestep {minutes} 20; !- Maximum HVAC Iterations !- =========== ALL OBJECTS IN CLASS: RUNPERIOD =========== RunPeriod, , !- Name 1, !- Begin Month 1, !- Begin Day of Month , !- Begin Year 12, !- End Month 31, !- End Day of Month , !- End Year Sunday, !- Day of Week for Start Day No, !- Use Weather File Holidays and Special Days No, !- Use Weather File Daylight Saving Period No, !- Apply Weekend Holiday Rule Yes, !- Use Weather File Rain Indicators Yes; !- Use Weather File Snow Indicators !- =========== ALL OBJECTS IN CLASS: RUNPERIODCONTROL:SPECIALDAYS =========== RunPeriodControl:SpecialDays, New Years Day, !- Name January 1, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Veterans Day, !- Name November 11, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Christmas, !- Name December 25, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Independence Day, !- Name July 4, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, MLK Day, !- Name 3rd Monday in January, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Presidents Day, !- Name 3rd Monday in February, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Memorial Day, !- Name Last Monday in May, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Labor Day, !- Name 1st Monday in September, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Columbus Day, !- Name 2nd Monday in October, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Thanksgiving, !- Name 4th Thursday in November,!- Start Date 1, !- Duration {days} Holiday; !- Special Day Type !- =========== ALL OBJECTS IN CLASS: RUNPERIODCONTROL:DAYLIGHTSAVINGTIME =========== RunPeriodControl:DaylightSavingTime, 2nd Sunday in March, !- Start Date 1st Sunday in November; !- End Date !- =========== ALL OBJECTS IN CLASS: LOCATION =========== ! Site:Location and design-day objects created by: ! ../../_p.bin/ddy2idf /projects/bigsim/weather/EnergyPlus/tmy3.new/all/USA_MN_Rochester.Intl.AP.726440_TMY3.ddy ! Site:Location, Rochester International Arpt_MN_USA Design_Conditions, !- Site:Location Name 43.90, !- Latitude {N+ S-} -92.50, !- Longitude {W- E+} -6.00, !- Time Zone Relative to GMT {GMT+/-} 398.00; !- Elevation {m} SizingPeriod:DesignDay, Rochester International Arpt Ann Htg 99.6% Condns DB, !- Name 1, !- Month 21, !- Day of Month WinterDesignDay,!- Day Type -26.2, !- Maximum Dry-Bulb Temperature {C} 0.0, !- Daily Dry-Bulb Temperature Range {C} DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type , !- Dry-Bulb Temperature Range Modifier Schedule Name Wetbulb, !- Humidity Condition Type -26.2, !- Wetbulb at Maximum Dry-Bulb {C} , !- Humidity Indicating Day Schedule Name , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} , !- Enthalpy at Maximum Dry-Bulb {J/kg} , !- Daily WetBulb Temperature Range {deltaC} 96634., !- Barometric Pressure {Pa} 5.7, !- Wind Speed {m/s} design conditions vs. traditional 6.71 m/s (15 mph) 310, !- Wind Direction {Degrees; N=0, S=180} No, !- Rain {Yes/No} No, !- Snow on ground {Yes/No} No, !- Daylight Savings Time Indicator ASHRAEClearSky, !- Solar Model Indicator , !- Beam Solar Day Schedule Name , !- Diffuse Solar Day Schedule Name , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) 0.00; !- Clearness {0.0 to 1.1} SizingPeriod:DesignDay, Rochester International Arpt Ann Clg .4% Condns DB=>MWB, !- Name 7, !- Month 21, !- Day of Month SummerDesignDay,!- Day Type 31.2, !- Maximum Dry-Bulb Temperature {C} 10.6, !- Daily Dry-Bulb Temperature Range {C} DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type , !- Dry-Bulb Temperature Range Modifier Schedule Name Wetbulb, !- Humidity Condition Type 23.1, !- Wetbulb at Maximum Dry-Bulb {C} , !- Humidity Indicating Day Schedule Name , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} , !- Enthalpy at Maximum Dry-Bulb {J/kg} , !- Daily WetBulb Temperature Range {deltaC} 96634., !- Barometric Pressure {Pa} 6.7, !- Wind Speed {m/s} design conditions vs. traditional 3.35 m/s (7mph) 200, !- Wind Direction {Degrees; N=0, S=180} No, !- Rain {Yes/No} No, !- Snow on ground {Yes/No} No, !- Daylight Savings Time Indicator ASHRAETau, !- Solar Model Indicator , !- Beam Solar Day Schedule Name , !- Diffuse Solar Day Schedule Name 0.404, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) 2.226; !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) !- =========== ALL OBJECTS IN CLASS: WATER MAINS TEMPERATURES =========== Site:WaterMainsTemperature, Correlation, !- Calculation Method , !- Temperature Schedule Name 6.375, !- Annual average outdoor air temperature {C} 33.5; !- Maximum difference in monthly average outdoor air temperatures {C} !- =========== ALL OBJECTS IN CLASS: Site:GroundTemperature:FCfactorMethod =========== Site:GroundTemperature:FCfactorMethod, 7.4, !- January Ground Temperature {C} -0.0, !- February Ground Temperature {C} -7.6, !- March Ground Temperature {C} -12.6, !- April Ground Temperature {C} -7.7, !- May Ground Temperature {C} 0.3, !- June Ground Temperature {C} 7.0, !- July Ground Temperature {C} 14.2, !- August Ground Temperature {C} 19.2, !- September Ground Temperature {C} 20.9, !- October Ground Temperature {C} 20.0, !- November Ground Temperature {C} 15.4; !- December Ground Temperature {C} !- =========== ALL OBJECTS IN CLASS: MATERIAL:REGULAR-R =========== Material:NoMass, Opaque Door panel_con, !- Name MediumRough, !- Roughness 0.475963827, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance !- =========== ALL OBJECTS IN CLASS: CONSTRUCTION =========== Construction, Swinging Door_con, !- Name Opaque Door panel_con; !- Outside Layer !- =========== ALL OBJECTS IN CLASS: SCHEDULETYPELIMITS =========== ScheduleTypeLimits, Any Number; !- Name ScheduleTypeLimits, Fraction, !- Name 0.0, !- Lower Limit Value 1.0, !- Upper Limit Value CONTINUOUS; !- Numeric Type ScheduleTypeLimits, Temperature, !- Name -60, !- Lower Limit Value 200, !- Upper Limit Value CONTINUOUS; !- Numeric Type ScheduleTypeLimits, On/Off, !- Name 0, !- Lower Limit Value 1, !- Upper Limit Value DISCRETE; !- Numeric Type ScheduleTypeLimits, Control Type, !- Name 0, !- Lower Limit Value 4, !- Upper Limit Value DISCRETE; !- Numeric Type ScheduleTypeLimits, Humidity, !- Name 10, !- Lower Limit Value 90, !- Upper Limit Value CONTINUOUS; !- Numeric Type ScheduleTypeLimits, Number; !- Name !- =========== ALL OBJECTS IN CLASS: SCHEDULE:COMPACT =========== Schedule:Compact, BLDG_LIGHT_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 5:00,0.18, !- Field 3 Until: 6:00,0.23, !- Field 4 Until: 7:00,0.178641345, !- Field 5 Until: 8:00,0.32621463, !- Field 6 Until: 12:00,0.69903135, !- Field 7 Until: 13:00,0.6213612, !- Field 8 Until: 17:00,0.69903135, !- Field 9 Until: 18:00,0.473787915, !- Field 10 Until: 20:00,0.32621463, !- Field 11 Until: 22:00,0.24854448, !- Field 12 Until: 23:00,0.178641345, !- Field 13 Until: 24:00,0.18, !- Field 14 For: Weekends, !- Field 15 Until: 24:00,0.18, !- Field 16 For: Holiday, !- Field 17 Until: 24:00,0.18, !- Field 18 For: WinterDesignDay, !- Field 19 Until: 24:00,0, !- Field 20 For: SummerDesignDay, !- Field 21 Until: 24:00,1, !- Field 22 For: CustomDay1, !- Field 23 Until: 24:00,0, !- Field 24 For: CustomDay2, !- Field 25 Until: 24:00,0; !- Field 26 Schedule:Compact, BLDG_EQUIP_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 6:00,0.4094775565, !- Field 3 Until: 8:00,0.4797526335, !- Field 3 Until: 12:00,0.959505267, !- Field 5 Until: 13:00,0.90193495098, !- Field 7 Until: 17:00,0.959505267, !- Field 9 Until: 18:00,0.4797526335, !- Field 11 Until: 23:00,0.1919010534, !- Field 13 Until: 24:00,0.1637910226, !- Field 13 For: Weekends, !- Field 15 Until: 24:00,0.1637910226, !- Field 16 For: Holiday, !- Field 18 Until: 24:00,0.1637910226, !- Field 19 For: WinterDesignDay, !- Field 21 Until: 24:00,0.0, !- Field 22 For: SummerDesignDay, !- Field 24 Until: 24:00,1.0, !- Field 25 For: CustomDay1, !- Field 27 Until: 24:00,0.0, !- Field 28 For: CustomDay2, !- Field 30 Until: 24:00,0.0; !- Field 31 Schedule:Compact, BLDG_OCC_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 6:00,0.0, !- Field 3 Until: 7:00,0.11, !- Field 5 Until: 8:00,0.21, !- Field 7 Until: 12:00,1.0, !- Field 9 Until: 13:00,0.53, !- Field 11 Until: 17:00,1.0, !- Field 13 Until: 18:00,0.32, !- Field 15 Until: 22:00,0.11, !- Field 17 Until: 23:00,0.05, !- Field 19 Until: 24:00,0.0, !- Field 21 For: Weekends, !- Field 23 Until: 24:00,0.0, !- Field 24 For: Holiday, !- Field 26 Until: 24:00,0.0, !- Field 27 For: WinterDesignDay, !- Field 29 Until: 24:00,0.0, !- Field 30 For: SummerDesignDay, !- Field 32 Until: 24:00,1.0, !- Field 33 For: CustomDay1, !- Field 35 Until: 24:00,0.0, !- Field 36 For: CustomDay2, !- Field 38 Until: 24:00,0.0; !- Field 39 Schedule:Compact, BLDG_OCC_SCH_w_SB, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0.11, Until: 08:00, 0.21, Until: 09:00, 1, Until: 10:00, 1, Until: 11:00, 0, Until: 12:00, 1, Until: 13:00, 0, Until: 14:00, 1, Until: 15:00, 0, Until: 16:00, 1, Until: 17:00, 1, Until: 18:00, 0.32, Until: 19:00, 0.11, Until: 20:00, 0.11, Until: 21:00, 0.11, Until: 22:00, 0.11, Until: 23:00, 0.05, Until: 24:00, 0, For: Weekends, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0, Until: 08:00, 0, Until: 09:00, 0, Until: 10:00, 0, Until: 11:00, 0, Until: 12:00, 0, Until: 13:00, 0, Until: 14:00, 0, Until: 15:00, 0, Until: 16:00, 0, Until: 17:00, 0, Until: 18:00, 0, Until: 19:00, 0, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: Holiday, Until: 24:00,0.0, For: WinterDesignDay, Until: 24:00,0.0, For: SummerDesignDay, Until: 24:00,1.0, For: CustomDay1, Until: 24:00,0.0, For: CustomDay2, Until: 24:00,0.0; Schedule:Compact, BLDG_OCC_SCH_wo_SB, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0.11, Until: 08:00, 0.21, Until: 09:00, 1, Until: 10:00, 1, Until: 11:00, 1, Until: 12:00, 1, Until: 13:00, 0.610394505402463, Until: 14:00, 1, Until: 15:00, 1, Until: 16:00, 1, Until: 17:00, 1, Until: 18:00, 0.32, Until: 19:00, 0.11, Until: 20:00, 0.11, Until: 21:00, 0.11, Until: 22:00, 0.11, Until: 23:00, 0.05, Until: 24:00, 0, For: Weekends, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0, Until: 08:00, 0, Until: 09:00, 0, Until: 10:00, 0, Until: 11:00, 0, Until: 12:00, 0, Until: 13:00, 0, Until: 14:00, 0, Until: 15:00, 0, Until: 16:00, 0, Until: 17:00, 0, Until: 18:00, 0, Until: 19:00, 0, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: Holiday, Until: 24:00,0.0, For: WinterDesignDay, Until: 24:00,0.0, For: SummerDesignDay, Until: 24:00,1.0, For: CustomDay1, Until: 24:00,0.0, For: CustomDay2, Until: 24:00,0.0; Schedule:Compact, Binary Occupancy, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 1, Until: 08:00, 1, Until: 09:00, 1, Until: 10:00, 1, Until: 11:00, 1, Until: 12:00, 1, Until: 13:00, 1, Until: 14:00, 1, Until: 15:00, 1, Until: 16:00, 1, Until: 17:00, 1, Until: 18:00, 1, Until: 19:00, 1, Until: 20:00, 1, Until: 21:00, 1, Until: 22:00, 1, Until: 23:00, 1, Until: 24:00, 0, For: Weekends, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0, Until: 08:00, 0, Until: 09:00, 0, Until: 10:00, 0, Until: 11:00, 0, Until: 12:00, 0, Until: 13:00, 0, Until: 14:00, 0, Until: 15:00, 0, Until: 16:00, 0, Until: 17:00, 0, Until: 18:00, 0, Until: 19:00, 0, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: Holiday, Until: 24:00,0.0, For: WinterDesignDay, Until: 24:00,0.0, For: SummerDesignDay, Until: 24:00,1.0, For: CustomDay1, Until: 24:00,0.0, For: CustomDay2, Until: 24:00,0.0; Schedule:Compact, INFIL_QUARTER_ON_SCH, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 07:00,1.0, !- Field 3 Until: 19:00,0.25, !- Field 5 Until: 24:00,1.0, !- Field 7 For: Saturday WinterDesignDay, !- Field 9 Until: 07:00,1.0, !- Field 10 Until: 18:00,0.25, !- Field 12 Until: 24:00,1.0, !- Field 14 For: Sunday Holidays AllOtherDays, !- Field 16 Until: 24:00,1.0; !- Field 17 Schedule:Compact, INFIL_Door_Opening_SCH, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 06:00,0.0, !- Field 3 Until: 07:00, 0.131, !- Field 6 Until: 08:00,1.0, !- Field 7 Until: 12:00, 0.131, !- Field 10 Until: 13:00,1.0, !- Field 11 Until: 17:00, 0.131, !- Field 14 Until: 18:00,1.0, !- Field 15 Until: 19:00, 0.131, !- Field 18 Until: 24:00,0.0, !- Field 19 For: Saturday Sunday Holidays AllOtherDays, !- Field 21 Until: 24:00,0.0; !- Field 22 Schedule:Compact, BLDG_SWH_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 7:00,0.0, !- Field 3 Until: 8:00,0.27, !- Field 5 Until: 9:00,0.55, !- Field 7 Until: 11:00,0.64, !- Field 9 Until: 12:00,0.82, !- Field 11 Until: 13:00,1.0, !- Field 13 Until: 14:00,0.91, !- Field 15 Until: 16:00,0.55, !- Field 17 Until: 17:00,0.73, !- Field 19 Until: 19:00,0.37, !- Field 21 Until: 20:00,0.18, !- Field 23 Until: 21:00,0.27, !- Field 25 Until: 22:00,0.09, !- Field 27 Until: 24:00,0.0, !- Field 29 For: Weekends, !- Field 31 Until: 24:00,0.0, !- Field 32 For: Holiday, !- Field 34 Until: 24:00,0.0, !- Field 35 For: WinterDesignDay, !- Field 37 Until: 7:00,0.0, !- Field 38 Until: 8:00,0.27, !- Field 40 Until: 9:00,0.55, !- Field 42 Until: 11:00,0.64, !- Field 44 Until: 12:00,0.82, !- Field 46 Until: 13:00,1.0, !- Field 48 Until: 14:00,0.91, !- Field 50 Until: 16:00,0.55, !- Field 52 Until: 17:00,0.73, !- Field 54 Until: 19:00,0.37, !- Field 56 Until: 20:00,0.18, !- Field 58 Until: 21:00,0.27, !- Field 60 Until: 22:00,0.09, !- Field 62 Until: 24:00,0.0, !- Field 64 For: SummerDesignDay, !- Field 66 Until: 7:00,0.0, !- Field 67 Until: 8:00,0.27, !- Field 69 Until: 9:00,0.55, !- Field 71 Until: 11:00,0.64, !- Field 73 Until: 12:00,0.82, !- Field 75 Until: 13:00,1.0, !- Field 77 Until: 14:00,0.91, !- Field 79 Until: 16:00,0.55, !- Field 81 Until: 17:00,0.73, !- Field 83 Until: 19:00,0.37, !- Field 85 Until: 20:00,0.18, !- Field 87 Until: 21:00,0.27, !- Field 89 Until: 22:00,0.09, !- Field 91 Until: 24:00,0.0, !- Field 93 For: CustomDay1, !- Field 95 Until: 24:00,0.0, !- Field 96 For: CustomDay2, !- Field 98 Until: 24:00,0.0; !- Field 99 Schedule:Compact, ALWAYS_ON, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, Exterior_Lgt_ALWAYS_ON, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 Schedule:Compact, Exterior_Lgt_189_1, !- Name Fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:Weekdays, !- Field 2 Until: 9:00,0.5, !- Field 3 Until: 23:00,1.0, !- Field 5 Until: 24:00,0.5, !- Field 7 For:Saturday, !- Field 9 Until: 24:00,0.5, !- Field 10 FOR:Sunday Holidays AllOtherDays, !- Field 12 Until: 24:00,0.5; !- Field 13 Schedule:Compact, ALWAYS_OFF, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, HVACOperationSchd, !- Name on/off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 06:00,0.0, !- Field 3 Until: 19:00,1.0, !- Field 5 Until: 24:00,0.0, !- Field 7 For: Weedends WinterDesignDay, !- Field 9 Until: 24:00,0.0, !- Field 10 For: Holidays AllOtherDays, !- Field 12 Until: 24:00,0.0; !- Field 13 Schedule:Compact, HVACOperationSchd_w_SB, !-Name Fraction, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 1, Until: 08:00, 1, Until: 09:00, 1, Until: 10:00, 1, Until: 11:00, 0, Until: 12:00, 1, Until: 13:00, 0, Until: 14:00, 1, Until: 15:00, 0, Until: 16:00, 1, Until: 17:00, 1, Until: 18:00, 1, Until: 19:00, 1, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: Weekends, Until: 01:00, 0, Until: 02:00, 0, Until: 03:00, 0, Until: 04:00, 0, Until: 05:00, 0, Until: 06:00, 0, Until: 07:00, 0, Until: 08:00, 0, Until: 09:00, 0, Until: 10:00, 0, Until: 11:00, 0, Until: 12:00, 0, Until: 13:00, 0, Until: 14:00, 0, Until: 15:00, 0, Until: 16:00, 0, Until: 17:00, 0, Until: 18:00, 0, Until: 19:00, 0, Until: 20:00, 0, Until: 21:00, 0, Until: 22:00, 0, Until: 23:00, 0, Until: 24:00, 0, For: SummerDesignDay, Until: 06:00, 0.0, Until: 19:00, 1.0, Until: 24:00, 0.0, For: WinterDesignDay, Until: 24:00, 0.0, For: Holidays AllOtherDays, Until: 24:00, 0.0; Schedule:Compact, PlantOnSched, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, ReheatCoilAvailSched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, CoolingCoilAvailSched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, HTGSETP_SCH_NO_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 6:00,15.56, !- Field 3 Until: 7:00,21.11, !- Field 5 Until: 19:00,21.11, !- Field 7 Until: 24:00,15.56, !- Field 9 For: Weekends, !- Field 11 Until: 24:00,15.56, !- Field 12 For: Holiday, !- Field 14 Until: 24:00,15.56, !- Field 15 For: WinterDesignDay, !- Field 17 Until: 24:00,21.11, !- Field 18 For: SummerDesignDay, !- Field 20 Until: 24:00,15.56, !- Field 21 For: CustomDay1, !- Field 23 Until: 24:00,15.56, !- Field 24 For: CustomDay2, !- Field 26 Until: 24:00,15.56; !- Field 27 Schedule:Compact, HTGSETP_SCH_NO_OPTIMUM_w_SB, !-Name Temperature, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 15.56, Until: 02:00, 15.56, Until: 03:00, 15.56, Until: 04:00, 15.56, Until: 05:00, 15.56, Until: 06:00, 15.56, Until: 07:00, 21.11, Until: 08:00, 21.11, Until: 09:00, 21.11, Until: 10:00, 21.11, Until: 11:00, 20.5544444444444, Until: 12:00, 21.11, Until: 13:00, 20.5544444444444, Until: 14:00, 21.11, Until: 15:00, 20.5544444444444, Until: 16:00, 21.11, Until: 17:00, 21.11, Until: 18:00, 21.11, Until: 19:00, 21.11, Until: 20:00, 15.56, Until: 21:00, 15.56, Until: 22:00, 15.56, Until: 23:00, 15.56, Until: 24:00, 15.56, For: Weekends, Until: 01:00, 15.56, Until: 02:00, 15.56, Until: 03:00, 15.56, Until: 04:00, 15.56, Until: 05:00, 15.56, Until: 06:00, 15.56, Until: 07:00, 15.56, Until: 08:00, 15.56, Until: 09:00, 15.56, Until: 10:00, 15.56, Until: 11:00, 15.56, Until: 12:00, 15.56, Until: 13:00, 15.56, Until: 14:00, 15.56, Until: 15:00, 15.56, Until: 16:00, 15.56, Until: 17:00, 15.56, Until: 18:00, 15.56, Until: 19:00, 15.56, Until: 20:00, 15.56, Until: 21:00, 15.56, Until: 22:00, 15.56, Until: 23:00, 15.56, Until: 24:00, 15.56, For: Holiday, Until: 24:00,15.56, For: WinterDesignDay, Until: 24:00,21.11, For: SummerDesignDay, Until: 24:00,15.56, For: CustomDay1, Until: 24:00,15.56, For: CustomDay2, Until: 24:00,15.56; Schedule:Compact, HTGSETP_SCH_YES_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 6:00,15.56, !- Field 3 Until: 7:00,17.8, !- Field 5 Until: 8:00,20.0, !- Field 7 Until: 19:00,21.11, !- Field 9 Until: 24:00,15.56, !- Field 11 For: Weekends, !- Field 13 Until: 24:00,15.56, !- Field 14 For: Holiday, !- Field 16 Until: 24:00,15.56, !- Field 17 For: WinterDesignDay, !- Field 19 Until: 24:00,21.11, !- Field 20 For: SummerDesignDay, !- Field 22 Until: 24:00,15.56, !- Field 23 For: CustomDay1, !- Field 25 Until: 24:00,15.56, !- Field 26 For: CustomDay2, !- Field 28 Until: 24:00,15.56; !- Field 29 Schedule:Compact, CLGSETP_SCH_NO_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 6:00,29.44, !- Field 3 Until: 7:00,23.89, !- Field 5 Until: 18:00,23.89, !- Field 7 Until: 24:00,29.44, !- Field 9 For: Weekends, !- Field 11 Until: 24:00,29.44, !- Field 12 For: Holiday, !- Field 14 Until: 24:00,29.44, !- Field 15 For: WinterDesignDay, !- Field 17 Until: 24:00,29.44, !- Field 18 For: SummerDesignDay, !- Field 20 Until: 24:00,23.89, !- Field 21 For: CustomDay1, !- Field 23 Until: 24:00,29.44, !- Field 24 For: CustomDay2, !- Field 26 Until: 24:00,29.44; !- Field 27 Schedule:Compact, CLGSETP_SCH_NO_OPTIMUM_w_SB, !-Name Temperature, !-Schedule Type Limits Name Through: 12/31, For: Weekdays, Until: 01:00, 29.44, Until: 02:00, 29.44, Until: 03:00, 29.44, Until: 04:00, 29.44, Until: 05:00, 29.44, Until: 06:00, 29.44, Until: 07:00, 23.89, Until: 08:00, 23.89, Until: 09:00, 23.89, Until: 10:00, 23.89, Until: 11:00, 24.4455555555556, Until: 12:00, 23.89, Until: 13:00, 24.4455555555556, Until: 14:00, 23.89, Until: 15:00, 24.4455555555556, Until: 16:00, 23.89, Until: 17:00, 23.89, Until: 18:00, 23.89, Until: 19:00, 29.44, Until: 20:00, 29.44, Until: 21:00, 29.44, Until: 22:00, 29.44, Until: 23:00, 29.44, Until: 24:00, 29.44, For: Weekends, Until: 01:00, 29.44, Until: 02:00, 29.44, Until: 03:00, 29.44, Until: 04:00, 29.44, Until: 05:00, 29.44, Until: 06:00, 29.44, Until: 07:00, 29.44, Until: 08:00, 29.44, Until: 09:00, 29.44, Until: 10:00, 29.44, Until: 11:00, 29.44, Until: 12:00, 29.44, Until: 13:00, 29.44, Until: 14:00, 29.44, Until: 15:00, 29.44, Until: 16:00, 29.44, Until: 17:00, 29.44, Until: 18:00, 29.44, Until: 19:00, 29.44, Until: 20:00, 29.44, Until: 21:00, 29.44, Until: 22:00, 29.44, Until: 23:00, 29.44, Until: 24:00, 29.44, For: Holiday, Until: 24:00,29.44, For: WinterDesignDay, Until: 24:00,29.44, For: SummerDesignDay, Until: 24:00,23.89, For: CustomDay1, Until: 24:00,29.44, For: CustomDay2, Until: 24:00,29.44; Schedule:Compact, CLGSETP_SCH_YES_OPTIMUM, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 6:00,29.44, !- Field 3 Until: 7:00,27.8, !- Field 5 Until: 8:00,25.6, !- Field 7 Until: 18:00,23.89, !- Field 9 Until: 24:00,29.44, !- Field 11 For: Weekends, !- Field 13 Until: 24:00,29.44, !- Field 14 For: Holiday, !- Field 16 Until: 24:00,29.44, !- Field 17 For: WinterDesignDay, !- Field 19 Until: 24:00,29.44, !- Field 20 For: SummerDesignDay, !- Field 22 Until: 24:00,23.89, !- Field 23 For: CustomDay1, !- Field 25 Until: 24:00,29.44, !- Field 26 For: CustomDay2, !- Field 28 Until: 24:00,29.44; !- Field 29 Schedule:Compact, CLGSETP_SCH_NO_SETBACK, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: WeekDays, !- Field 2 Until: 6:00,23.89, !- Field 3 Until: 7:00,23.89, !- Field 5 Until: 18:00,23.89, !- Field 7 Until: 24:00,23.89, !- Field 9 For: Weekends, !- Field 11 Until: 24:00,23.89, !- Field 12 For: Holiday, !- Field 14 Until: 24:00,23.89, !- Field 15 For: WinterDesignDay, !- Field 17 Until: 24:00,29.44, !- Field 18 For: SummerDesignDay, !- Field 20 Until: 24:00,23.89, !- Field 21 For: CustomDay1, !- Field 23 Until: 24:00,23.89, !- Field 24 For: CustomDay2, !- Field 26 Until: 24:00,23.89; !- Field 27 Schedule:Compact, Humidity Setpoint Schedule, !- Name Humidity, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 24:00,50, !- Field 3 For: Saturday WinterDesignDay, !- Field 5 Until: 24:00,50, !- Field 6 For: Sunday Holidays AllOtherDays, !- Field 8 Until: 24:00,50; !- Field 9 Schedule:Compact, MinOA_MotorizedDamper_Sched, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 07:00,0.0, !- Field 3 Until: 19:00,1.0, !- Field 5 Until: 24:00,0.0, !- Field 7 For: Weekends WinterDesignDay, !- Field 9 Until: 24:00,0.0, !- Field 10 For: Holidays AllOtherDays, !- Field 12 Until: 24:00,0.0; !- Field 13 Schedule:Compact, MinOA_Sched, !- Name fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, Dual Zone Control Type Sched, !- Name Control Type, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,4; !- Field 3 Schedule:Compact, Seasonal-Reset-Supply-Air-Temp-Sch, !- Name Temperature, !- Schedule Type Limits Name Through: 3/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,13.0, !- Field 3 Through: 9/30, !- Field 5 For: AllDays, !- Field 6 Until: 24:00,13.0, !- Field 7 Through: 12/31, !- Field 9 For: AllDays, !- Field 10 Until: 24:00,13.0; !- Field 11 Schedule:Compact, CW-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,6.7; !- Field 3 Schedule:Compact, HW-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.; !- Field 3 Schedule:Compact, Heating-Supply-Air-Temp-Sch, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,16.0; !- Field 3 Schedule:Compact, ACTIVITY_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,120.; !- Field 3 Schedule:Compact, WORK_EFF_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, AIR_VELO_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, CLOTHING_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 04/30, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0, !- Field 3 Through: 09/30, !- Field 5 For: AllDays, !- Field 6 Until: 24:00,0.5, !- Field 7 Through: 12/31, !- Field 9 For: AllDays, !- Field 10 Until: 24:00,1.0; !- Field 11 Schedule:Compact, SHADING_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, Core_ZN Water Equipment Latent fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.05; !- Field 3 Schedule:Compact, Core_ZN Water Equipment Sensible fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, Core_ZN Water Equipment Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,48.8; !- Field 3 Schedule:Compact, Core_ZN Water Equipment Hot Supply Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,55; !- Field 3 Schedule:Compact, SHWSys1-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60; !- Field 3 Schedule:Compact, SHWSys1 Water Heater Setpoint Temperature Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.00; !- Field 3 Schedule:Compact, SHWSys1 Water Heater Ambient Temperature Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,22.0; !- Field 3 !- =========== ALL OBJECTS IN CLASS: CONSTRUCTION =========== ! !- =========== ALL OBJECTS IN CLASS: MATERIAL:REGULAR =========== Material, Std Wood 6inch, !- Name MediumSmooth, !- Roughness 0.15, !- Thickness {m} 0.12, !- Conductivity {W/m-K} 540.0000, !- Density {kg/m3} 1210, !- Specific Heat {J/kg-K} 0.9000000, !- Thermal Absorptance 0.7000000, !- Solar Absorptance 0.7000000; !- Visible Absorptance Material, AC02 Acoustic Ceiling, !- Name MediumSmooth, !- Roughness 1.2700000E-02, !- Thickness {m} 5.7000000E-02, !- Conductivity {W/m-K} 288.0000, !- Density {kg/m3} 1339.000, !- Specific Heat {J/kg-K} 0.9000000, !- Thermal Absorptance 0.7000000, !- Solar Absorptance 0.2000000; !- Visible Absorptance Material, F07 25mm stucco, !- Name Smooth, !- Roughness 0.0254, !- Thickness {m} 0.72, !- Conductivity {W/m-K} 1856, !- Density {kg/m3} 840, !- Specific Heat {J/kg-K} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material, F08 Metal surface, !- Name Smooth, !- Roughness 0.0008, !- Thickness {m} 45.28, !- Conductivity {W/m-K} 7824, !- Density {kg/m3} 500; !- Specific Heat {J/kg-K} Material, F08 Metal roof surface, !- Name Smooth, !- Roughness 0.0008, !- Thickness {m} 45.28, !- Conductivity {W/m-K} 7824, !- Density {kg/m3} 500, !- Specific Heat {J/kg-K} 0.9, !- Absorptance:Thermal 0.7; !- Absorptance:Solar Material, F12 Asphalt shingles, !- Name VeryRough, !- Roughness 0.0032, !- Thickness {m} 0.04, !- Conductivity {W/m-K} 1120, !- Density {kg/m3} 1260, !- Specific Heat {J/kg-K} 0.9, !- Absorptance:Thermal 0.7; !- Absorptance:Solar Material, F13 Built-up roofing, !- Name Rough, !- Roughness 0.0095, !- Thickness {m} 0.16, !- Conductivity {W/m-K} 1120, !- Density {kg/m3} 1460, !- Specific Heat {J/kg-K} 0.9, !- Absorptance:Thermal 0.7; !- Absorptance:Solar Material, G01 13mm gypsum board, !- Name Smooth, !- Roughness 0.0127, !- Thickness {m} 0.1600, !- Conductivity {W/m-K} 800.0000, !- Density {kg/m3} 1090.0000, !- Specific Heat {J/kg-K} 0.9000, !- Absorptance:Thermal 0.7000, !- Absorptance:Solar 0.5000; !- Absorptance:Visible Material, G01 16mm gypsum board, !- Name MediumSmooth, !- Roughness 0.0159, !- Thickness {m} 0.16, !- Conductivity {W/m-K} 800, !- Density {kg/m3} 1090; !- Specific Heat {J/kg-K} Material, G02 16mm plywood, !- Name Smooth, !- Roughness 0.0159, !- Thickness {m} 0.12, !- Conductivity {W/m-K} 544, !- Density {kg/m3} 1210; !- Specific Heat {J/kg-K} Material, M14 150mm heavyweight concrete roof, !- Name MediumRough, !- Roughness 0.1524, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 100mm Normalweight concrete wall, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.1016, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 200mm Normalweight concrete wall, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.2032, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 100mm Normalweight concrete floor, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.1016, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 150mm Normalweight concrete floor, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.1524, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, 200mm Normalweight concrete floor, !- Name - based on 90.1-2004 Appendix-Table A3-1B MediumRough, !- Roughness 0.2032, !- Thickness {m} 2.31, !- Conductivity {W/m-K} 2322, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, M10 200mm concrete block wall, !- Name MediumRough, !- Roughness 0.2032, !- Thickness {m} 0.72, !- Conductivity {W/m-K} 800, !- Density {kg/m3} 832; !- Specific Heat {J/kg-K} Material, M10 200mm concrete block basement wall, !- Name MediumRough, !- Roughness 0.2032, !- Thickness {m} 1.326, !- Conductivity {W/m-K} 1842, !- Density {kg/m3} 912; !- Specific Heat {J/kg-K} Material:NoMass, CP02 CARPET PAD, !- Name VeryRough, !- Roughness 0.21648, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.8; !- Visible Absorptance Material:NoMass, Air_Wall_Material, !- Name Rough, !- Roughness 0.2079491, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7; !- Solar Absorptance Material:NoMass, Nonres_Roof_Insulation, !- Name MediumSmooth, !- Roughness 8.09838681889561, !- Thermal Resistance {m2-K/W} 0.9, !- Absorptance:Thermal 0.7, !- Absorptance:Solar 0.7; !- Absorptance:Visible Material:NoMass, Res_Roof_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Semiheated_Roof_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Nonres_Exterior_Wall_Insulation, !- Name MediumSmooth, !- Roughness 3.06941962105791, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Res_Exterior_Wall_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Semiheated_Exterior_Wall_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Nonres_Floor_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Res_Floor_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Semiheated_Floor_Insulation, !- Name MediumSmooth, !- Roughness 0.0299387330245182, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance Material:NoMass, Std Opaque Door Panel, !- Name MediumRough, !- Roughness 0.123456790123457, !- (corresponds to default RSI-0.12327 or R-0.7) Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7, !- Solar Absorptance 0.7; !- Visible Absorptance !- =========== ALL OBJECTS IN CLASS: CONSTRUCTION =========== Construction, InteriorFurnishings, !- Name Std Wood 6inch; !- Outside Layer Construction, Air_Wall, !- Name Air_Wall_Material; !- Outside Layer Construction, DropCeiling, !- Name AC02 Acoustic Ceiling; !- Outside Layer Construction, OpaqueDoor, !- Name Std Opaque Door Panel; !- Outside Layer Construction, AtticRoofDeck, !- Name F12 Asphalt shingles, !- Outside Layer G02 16mm plywood; !- Layer 2 Construction, int_wall, !- Name G01 13mm gypsum board, !- Outside Layer G01 13mm gypsum board; !- Layer 2 Construction, ext_slab_8in_with_carpet,!- Name 200mm Normalweight concrete floor, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, ext_slab_8in, !- Name 200mm Normalweight concrete floor; !- Outside Layer Construction, ext_slab_6in_with_carpet,!- Name 150mm Normalweight concrete floor, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, ext_slab_6in, !- Name 150mm Normalweight concrete floor; !- Outside Layer Construction, int_slab_floor, !- Name 100mm Normalweight concrete floor, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, int_slab_ceiling, !- Name CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor; !- Layer 2 Construction, basement_wall, !- Name M10 200mm concrete block basement wall; !- Outside Layer Construction, int_wood_floor, !- Name AC02 Acoustic Ceiling, !- Outside Layer G02 16mm plywood, !- Layer 2 CP02 CARPET PAD; !- Layer 3 Construction, ext_soffit_floor, !- Name G02 16mm plywood; !- Outside Layer Construction, nonres_roof, !- Name Nonres_Roof_Insulation, !- Outside Layer G01 16mm gypsum board; !- Layer #2 Construction, res_roof, !- Name Res_Roof_Insulation, !- Outside Layer G01 16mm gypsum board; !- Layer #2 Construction, semiheated_roof, !- Name Semiheated_Roof_Insulation, !- Outside Layer G01 16mm gypsum board; !- Layer #2 Construction, nonres_roof_floor, !- Name - Other side zone surface definition for nonres_roof G01 16mm gypsum board, !- Outside Layer Nonres_Roof_Insulation; !- Layer #2 Construction, res_roof_floor, !- Name - Other side zone surface definition for res_roof G01 16mm gypsum board, !- Outside Layer Res_Roof_Insulation; !- Layer #2 Construction, semiheated_roof_floor, !- Name - Other side zone surface definition for semiheated_roof G01 16mm gypsum board, !- Outside Layer Semiheated_Roof_Insulation; !- Layer #2 Construction, nonres_ext_wall, !- Name F07 25mm stucco, !- Outside Layer G01 16mm gypsum board, !- Layer #2 Nonres_Exterior_Wall_Insulation, !- Layer #3 G01 16mm gypsum board; !- Layer #4 Construction, res_ext_wall, !- Name F07 25mm stucco, !- Outside Layer G01 16mm gypsum board, !- Layer #1 Res_Exterior_Wall_Insulation, !- Layer #2 G01 16mm gypsum board; !- Layer #3 Construction, semiheated_ext_wall, !- Name F07 25mm stucco, !- Outside Layer G01 16mm gypsum board, !- Layer #1 Semiheated_Exterior_Wall_Insulation, !- Layer #2 G01 16mm gypsum board; !- Layer #3 Construction, nonres_floor, !- Name Nonres_Floor_Insulation, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 CP02 CARPET PAD; !- Layer #2 Construction, res_floor, !- Name Res_Floor_Insulation, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 CP02 CARPET PAD; !- Layer #2 Construction, semiheated_floor, !- Name Semiheated_Floor_Insulation, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 CP02 CARPET PAD; !- Layer #2 Construction, nonres_floor_ceiling, !- Name - reverse ordered layers for nonres_floor CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 Nonres_Floor_Insulation; !- Layer #2 Construction, res_floor_ceiling, !- Name - reverse ordered layers for res_floor CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 Res_Floor_Insulation; !- Layer #2 Construction, semiheated_floor_ceiling, !- Name - reverse ordered layers for semiheated_floor CP02 CARPET PAD, !- Outside Layer 100mm Normalweight concrete floor, !- Layer #1 Semiheated_Floor_Insulation; !- Layer #2 !- =========== ALL OBJECTS IN CLASS: WINDOWMATERIAL:SIMPLEGLAZINGSYSTEM =========== WindowMaterial:SimpleGlazingSystem, Glazing Layer, !- Name 1.9306084, !- U-Factor {W/m2-K} 0.38, !- Solar Heat Gain Coefficient 0.418; !- Visible Transmittance Construction, Window_U_0.34_SHGC_0.38, !- Name Glazing Layer; !- Outside Layer !- =========== ALL OBJECTS IN CLASS: GLOBALGEOMETRYRULES =========== GlobalGeometryRules, UpperLeftCorner, !- Starting Vertex Position Counterclockwise, !- Vertex Entry Direction Relative, !- Coordinate System Relative; !- Daylighting Reference Point Coordinate System Construction:FfactorGroundFloor, Core_ZN_floor_Ffactor, !- Name 0.88281, !- F-Factor 149.65740000000005, !- Area 0; !- PerimeterExposed Construction:FfactorGroundFloor, Perimeter_ZN_1_floor_Ffactor, !- Name 0.88281, !- F-Factor 113.45000000000002, !- Area 27.69; !- PerimeterExposed Construction:FfactorGroundFloor, Perimeter_ZN_2_floor_Ffactor, !- Name 0.88281, !- F-Factor 67.29999999999995, !- Area 18.46; !- PerimeterExposed Construction:FfactorGroundFloor, Perimeter_ZN_3_floor_Ffactor, !- Name 0.88281, !- F-Factor 113.44999999999999, !- Area 27.69; !- PerimeterExposed Construction:FfactorGroundFloor, Perimeter_ZN_4_floor_Ffactor, !- Name 0.88281, !- F-Factor 67.30000000000001, !- Area 18.46; !- PerimeterExposed !- =========== ALL OBJECTS IN CLASS: ZONE =========== Zone, Core_ZN, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, Perimeter_ZN_1, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, Perimeter_ZN_2, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, Perimeter_ZN_3, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, Perimeter_ZN_4, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, Attic, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1.0000, !- Multiplier autocalculate, !- Ceiling Height {m} autocalculate, !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm No; !- Part of Total Floor Area !- =========== ALL OBJECTS IN CLASS: BUILDINGSURFACE:DETAILED =========== BuildingSurface:Detailed, Core_ZN_floor, !- Name Floor, !- Surface Type Core_ZN_floor_Ffactor, !- Construction Name Core_ZN, !- Zone Name Adiabatic, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,5.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_ZN_wall_south, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_ZN, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_1_wall_north, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_ZN_wall_east, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_ZN, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_2_wall_west,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_ZN_wall_north, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_ZN, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_3_wall_south, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_ZN_ceiling, !- Name Ceiling, !- Surface Type nonres_roof, !- Construction Name Core_ZN, !- Zone Name Surface, !- Outside Boundary Condition Attic_floor_core, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 22.6900,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Core_ZN_wall_west, !- Name Wall, !- Surface Type int_wall, !- Construction Name Core_ZN, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_4_wall_east,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_1_floor, !- Name Floor, !- Surface Type Perimeter_ZN_1_floor_Ffactor, !- Construction Name Perimeter_ZN_1, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 27.6900,0.0000,0.0000, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,5.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_1_wall_west,!- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_4_wall_south, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_1_wall_south, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_ZN_1, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 27.6900,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 27.6900,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_1_ceiling, !- Name Ceiling, !- Surface Type nonres_roof, !- Construction Name Perimeter_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Attic_floor_perimeter_south, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,0.0000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 5.0000,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_1_wall_east,!- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_2_wall_south, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 27.6900,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_1_wall_north, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_1, !- Zone Name Surface, !- Outside Boundary Condition Core_ZN_wall_south, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_2_floor, !- Name Floor, !- Surface Type Perimeter_ZN_2_floor_Ffactor, !- Construction Name Perimeter_ZN_2, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 1 {m} 27.6900,18.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 27.6900,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,5.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_2_wall_east,!- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_ZN_2, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 27.6900,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 27.6900,18.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 27.6900,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_2_wall_north, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_3_wall_east,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 27.6900,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,18.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_2_ceiling, !- Name Ceiling, !- Surface Type nonres_roof, !- Construction Name Perimeter_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Attic_floor_perimeter_east, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 27.6900,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 27.6900,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_2_wall_south, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_1_wall_east,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 27.6900,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 27.6900,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_2_wall_west,!- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_2, !- Zone Name Surface, !- Outside Boundary Condition Core_ZN_wall_east, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_3_floor, !- Name Floor, !- Surface Type Perimeter_ZN_3_floor_Ffactor, !- Construction Name Perimeter_ZN_3, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 1 {m} 0.0000,18.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 27.6900,18.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,13.4600,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_3_wall_south, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Core_ZN_wall_north, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 22.6900,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_3_wall_west,!- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_4_wall_north, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 0.0000,18.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_3_ceiling, !- Name Ceiling, !- Surface Type nonres_roof, !- Construction Name Perimeter_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Attic_floor_perimeter_north, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 3 {m} 27.6900,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_3_wall_north, !- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_ZN_3, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 27.6900,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,18.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,18.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_3_wall_east,!- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_3, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_2_wall_north, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 27.6900,18.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 27.6900,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_4_floor, !- Name Floor, !- Surface Type Perimeter_ZN_4_floor_Ffactor, !- Construction Name Perimeter_ZN_4, !- Zone Name GroundFCfactorMethod, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,18.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,13.4600,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_4_wall_south, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_1_wall_west,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_4_ceiling, !- Name Ceiling, !- Surface Type nonres_roof, !- Construction Name Perimeter_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Attic_floor_perimeter_west, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 3 {m} 0.0000,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_4_wall_north, !- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_3_wall_west,!- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,18.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_4_wall_east,!- Name Wall, !- Surface Type int_wall, !- Construction Name Perimeter_ZN_4, !- Zone Name Surface, !- Outside Boundary Condition Core_ZN_wall_west, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,5.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 5.0000,13.4600,0.0000, !- X,Y,Z ==> Vertex 3 {m} 5.0000,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Perimeter_ZN_4_wall_west,!- Name Wall, !- Surface Type nonres_ext_wall, !- Construction Name Perimeter_ZN_4, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 0.0000,18.4600,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_soffit_west, !- Name Floor, !- Surface Type ext_soffit_floor, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices -0.6000,19.0600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 0.0000,18.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} -0.6000,-0.6000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_soffit_south, !- Name Floor, !- Surface Type ext_soffit_floor, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,0.0000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 28.2900,-0.6000,3.0500, !- X,Y,Z ==> Vertex 3 {m} -0.6000,-0.6000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_soffit_east, !- Name Floor, !- Surface Type ext_soffit_floor, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 28.2900,19.0600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 28.2900,-0.6000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 27.6900,0.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 27.6900,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_floor_perimeter_south, !- Name Floor, !- Surface Type nonres_roof_floor, !- Construction Name Attic, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_1_ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 27.6900,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_floor_perimeter_west, !- Name Floor, !- Surface Type nonres_roof_floor, !- Construction Name Attic, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_4_ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 5.0000,5.0000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 0.0000,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_floor_perimeter_east, !- Name Floor, !- Surface Type nonres_roof_floor, !- Construction Name Attic, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_2_ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 27.6900,18.4600,3.0500, !- X,Y,Z ==> Vertex 3 {m} 27.6900,0.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_floor_core, !- Name Floor, !- Surface Type nonres_roof_floor, !- Construction Name Attic, !- Zone Name Surface, !- Outside Boundary Condition Core_ZN_ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 5.0000,13.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 22.6900,5.0000,3.0500, !- X,Y,Z ==> Vertex 3 {m} 5.0000,5.0000,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_floor_perimeter_north, !- Name Floor, !- Surface Type nonres_roof_floor, !- Construction Name Attic, !- Zone Name Surface, !- Outside Boundary Condition Perimeter_ZN_3_ceiling, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,18.4600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 27.6900,18.4600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 22.6900,13.4600,3.0500, !- X,Y,Z ==> Vertex 3 {m} 5.0000,13.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_soffit_north, !- Name Floor, !- Surface Type ext_soffit_floor, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices -0.6000,19.0600,3.0500, !- X,Y,Z ==> Vertex 1 {m} 28.2900,19.0600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 27.6900,18.4600,3.0500, !- X,Y,Z ==> Vertex 3 {m} 0.0000,18.4600,3.0500; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_roof_north, !- Name Roof, !- Surface Type AtticRoofDeck, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 28.2900,19.0600,3.0500, !- X,Y,Z ==> Vertex 1 {m} -0.6000,19.0600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 9.2300,9.2300,6.3300, !- X,Y,Z ==> Vertex 3 {m} 18.4600,9.2300,6.3300; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, Attic_roof_west, !- Name Roof, !- Surface Type AtticRoofDeck, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 3, !- Number of Vertices -0.6000,19.0600,3.0500, !- X,Y,Z ==> Vertex 1 {m} -0.6000,-0.6000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 9.2300,9.2300,6.3300; !- X,Y,Z ==> Vertex 3 {m} BuildingSurface:Detailed, Attic_roof_east, !- Name Roof, !- Surface Type AtticRoofDeck, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 3, !- Number of Vertices 28.2900,-0.6000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 28.2900,19.0600,3.0500, !- X,Y,Z ==> Vertex 2 {m} 18.4600,9.2300,6.3300; !- X,Y,Z ==> Vertex 3 {m} BuildingSurface:Detailed, Attic_roof_south, !- Name Roof, !- Surface Type AtticRoofDeck, !- Construction Name Attic, !- Zone Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices -0.6000,-0.6000,3.0500, !- X,Y,Z ==> Vertex 1 {m} 28.2900,-0.6000,3.0500, !- X,Y,Z ==> Vertex 2 {m} 18.4600,9.2300,6.3300, !- X,Y,Z ==> Vertex 3 {m} 9.2300,9.2300,6.3300; !- X,Y,Z ==> Vertex 4 {m} !- =========== ALL OBJECTS IN CLASS: FENESTRATIONSURFACE:DETAILED =========== FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_Window_1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 1.390,0.0000,2.4240, !- X,Y,Z ==> Vertex 1 {m} 1.390,0.0000,0.9000, !- X,Y,Z ==> Vertex 2 {m} 3.220,0.0000,0.9000, !- X,Y,Z ==> Vertex 3 {m} 3.220,0.0000,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_Window_2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 6.010,0.0000,2.4240, !- X,Y,Z ==> Vertex 1 {m} 6.010,0.0000,0.9000, !- X,Y,Z ==> Vertex 2 {m} 7.840,0.0000,0.9000, !- X,Y,Z ==> Vertex 3 {m} 7.840,0.0000,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_Window_3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 10.620,0.0000,2.4240, !- X,Y,Z ==> Vertex 1 {m} 10.620,0.0000,0.9000, !- X,Y,Z ==> Vertex 2 {m} 12.450,0.0000,0.9000, !- X,Y,Z ==> Vertex 3 {m} 12.450,0.0000,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_Window_4, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 15.240,0.0000,2.4240, !- X,Y,Z ==> Vertex 1 {m} 15.240,0.0000,0.9000, !- X,Y,Z ==> Vertex 2 {m} 17.070,0.0000,0.9000, !- X,Y,Z ==> Vertex 3 {m} 17.070,0.0000,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_Window_5, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 19.850,0.0000,2.4240, !- X,Y,Z ==> Vertex 1 {m} 19.850,0.0000,0.9000, !- X,Y,Z ==> Vertex 2 {m} 21.680,0.0000,0.9000, !- X,Y,Z ==> Vertex 3 {m} 21.680,0.0000,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_Window_6, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 24.470,0.0000,2.4240, !- X,Y,Z ==> Vertex 1 {m} 24.470,0.0000,0.9000, !- X,Y,Z ==> Vertex 2 {m} 26.300,0.0000,0.9000, !- X,Y,Z ==> Vertex 3 {m} 26.300,0.0000,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_1_wall_south_door, !- Name GlassDoor, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_1_wall_south, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 12.930,0.0000,2.1340, !- X,Y,Z ==> Vertex 1 {m} 12.930,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 14.760,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 14.760,0.0000,2.1340; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_2_wall_east_Window_4, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_2_wall_east,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 27.690,15.2400,2.4240, !- X,Y,Z ==> Vertex 1 {m} 27.690,15.2400,0.9000, !- X,Y,Z ==> Vertex 2 {m} 27.690,17.0700,0.9000, !- X,Y,Z ==> Vertex 3 {m} 27.690,17.0700,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_2_wall_east_Window_3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_2_wall_east,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 27.690,10.6200,2.4240, !- X,Y,Z ==> Vertex 1 {m} 27.690,10.6200,0.9000, !- X,Y,Z ==> Vertex 2 {m} 27.690,12.4500,0.9000, !- X,Y,Z ==> Vertex 3 {m} 27.690,12.4500,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_2_wall_east_Window_2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_2_wall_east,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 27.690,6.0100,2.4240, !- X,Y,Z ==> Vertex 1 {m} 27.690,6.0100,0.9000, !- X,Y,Z ==> Vertex 2 {m} 27.690,7.8400,0.9000, !- X,Y,Z ==> Vertex 3 {m} 27.690,7.8400,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_2_wall_east_Window_1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_2_wall_east,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 27.690,1.3900,2.4240, !- X,Y,Z ==> Vertex 1 {m} 27.690,1.3900,0.9000, !- X,Y,Z ==> Vertex 2 {m} 27.690,3.2200,0.9000, !- X,Y,Z ==> Vertex 3 {m} 27.690,3.2200,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Window_1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 26.300,18.4600,2.4240, !- X,Y,Z ==> Vertex 1 {m} 26.300,18.4600,0.9000, !- X,Y,Z ==> Vertex 2 {m} 24.470,18.4600,0.9000, !- X,Y,Z ==> Vertex 3 {m} 24.470,18.4600,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Window_2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 21.680,18.4600,2.4240, !- X,Y,Z ==> Vertex 1 {m} 21.680,18.4600,0.9000, !- X,Y,Z ==> Vertex 2 {m} 19.850,18.4600,0.9000, !- X,Y,Z ==> Vertex 3 {m} 19.850,18.4600,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Window_3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 17.070,18.4600,2.4240, !- X,Y,Z ==> Vertex 1 {m} 17.070,18.4600,0.9000, !- X,Y,Z ==> Vertex 2 {m} 15.240,18.4600,0.9000, !- X,Y,Z ==> Vertex 3 {m} 15.240,18.4600,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Window_4, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 12.450,18.4600,2.4240, !- X,Y,Z ==> Vertex 1 {m} 12.450,18.4600,0.9000, !- X,Y,Z ==> Vertex 2 {m} 10.620,18.4600,0.9000, !- X,Y,Z ==> Vertex 3 {m} 10.620,18.4600,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Window_5, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.840,18.4600,2.4240, !- X,Y,Z ==> Vertex 1 {m} 7.840,18.4600,0.9000, !- X,Y,Z ==> Vertex 2 {m} 6.010,18.4600,0.9000, !- X,Y,Z ==> Vertex 3 {m} 6.010,18.4600,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Window_6, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.220,18.4600,2.4240, !- X,Y,Z ==> Vertex 1 {m} 3.220,18.4600,0.9000, !- X,Y,Z ==> Vertex 2 {m} 1.390,18.4600,0.9000, !- X,Y,Z ==> Vertex 3 {m} 1.390,18.4600,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_4_wall_west_Window_4, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_4_wall_west,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000,3.2200,2.4240, !- X,Y,Z ==> Vertex 1 {m} 0.000,3.2200,0.9000, !- X,Y,Z ==> Vertex 2 {m} 0.000,1.3900,0.9000, !- X,Y,Z ==> Vertex 3 {m} 0.000,1.3900,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_4_wall_west_Window_3, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_4_wall_west,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000,7.8400,2.4240, !- X,Y,Z ==> Vertex 1 {m} 0.000,7.8400,0.9000, !- X,Y,Z ==> Vertex 2 {m} 0.000,6.0100,0.9000, !- X,Y,Z ==> Vertex 3 {m} 0.000,6.0100,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_4_wall_west_Window_2, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_4_wall_west,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000,12.4500,2.4240, !- X,Y,Z ==> Vertex 1 {m} 0.000,12.4500,0.9000, !- X,Y,Z ==> Vertex 2 {m} 0.000,10.6200,0.9000, !- X,Y,Z ==> Vertex 3 {m} 0.000,10.6200,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_4_wall_west_Window_1, !- Name Window, !- Surface Type Window_U_0.34_SHGC_0.38, !- Construction Name Perimeter_ZN_4_wall_west,!- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.000,17.0700,2.4240, !- X,Y,Z ==> Vertex 1 {m} 0.000,17.0700,0.9000, !- X,Y,Z ==> Vertex 2 {m} 0.000,15.2400,0.9000, !- X,Y,Z ==> Vertex 3 {m} 0.000,15.2400,2.4240; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Door1, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object autocalculate, !- View Factor to Ground , !- Frame and Divider Name 1, !- Multiplier 4, !- Number of Vertices 14.911800279714,18.460000000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 14.911800279714,18.460000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 13.997400279714,18.460000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 13.997400279714,18.460000000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, Perimeter_ZN_3_wall_north_Door2, !- Name Door, !- Surface Type Swinging Door_con, !- Construction Name Perimeter_ZN_3_wall_north, !- Building Surface Name , !- Outside Boundary Condition Object autocalculate, !- View Factor to Ground , !- Frame and Divider Name 1, !- Multiplier 4, !- Number of Vertices 19.131920148775,18.460000000000,2.133600000000, !- X,Y,Z ==> Vertex 1 {m} 19.131920148775,18.460000000000,0.000000000000, !- X,Y,Z ==> Vertex 2 {m} 18.217520148775,18.460000000000,0.000000000000, !- X,Y,Z ==> Vertex 3 {m} 18.217520148775,18.460000000000,2.133600000000; !- X,Y,Z ==> Vertex 4 {m} !- =========== ALL OBJECTS IN CLASS: INTERNALMASS =========== InternalMass, Core_ZN_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Core_ZN, !- Zone Name 299.3148; !- Surface Area {m2} InternalMass, Perimeter_ZN_1_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_ZN_1, !- Zone Name 226.9000; !- Surface Area {m2} InternalMass, Perimeter_ZN_2_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_ZN_2, !- Zone Name 134.6000; !- Surface Area {m2} InternalMass, Perimeter_ZN_3_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_ZN_3, !- Zone Name 226.9000; !- Surface Area {m2} InternalMass, Perimeter_ZN_4_InternalMass_1, !- Name InteriorFurnishings, !- Construction Name Perimeter_ZN_4, !- Zone Name 134.6000; !- Surface Area {m2} !- =========== ALL OBJECTS IN CLASS: PEOPLE =========== People, Core_ZN, !- Name Core_ZN, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 16.5880764430522, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged; !- Mean Radiant Temperature Calculation Type People, Perimeter_ZN_1, !- Name Perimeter_ZN_1, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 16.5880764430522, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged; !- Mean Radiant Temperature Calculation Type People, Perimeter_ZN_2, !- Name Perimeter_ZN_2, !- Zone or ZoneList Name BLDG_OCC_SCH_w_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 16.5880764430522, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged; !- Mean Radiant Temperature Calculation Type People, Perimeter_ZN_3, !- Name Perimeter_ZN_3, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 16.5880764430522, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged; !- Mean Radiant Temperature Calculation Type People, Perimeter_ZN_4, !- Name Perimeter_ZN_4, !- Zone or ZoneList Name BLDG_OCC_SCH_wo_SB, !- Number of People Schedule Name Area/Person, !- Number of People Calculation Method , !- Number of People , !- People per Zone Floor Area {person/m2} 16.5880764430522, !- Zone Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings ZoneAveraged; !- Mean Radiant Temperature Calculation Type !- =========== ALL OBJECTS IN CLASS: LIGHTS =========== Lights, Core_ZN_Lights, !- Name Core_ZN, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_ZN_1_Lights, !- Name Perimeter_ZN_1, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_ZN_2_Lights, !- Name Perimeter_ZN_2, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_ZN_3_Lights, !- Name Perimeter_ZN_3, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, Perimeter_ZN_4_Lights, !- Name Perimeter_ZN_4, !- Zone or ZoneList Name BLDG_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 6.888902667, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable LightsWired, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature !- =========== ALL OBJECTS IN CLASS: ELECTRICEQUIPMENT =========== ElectricEquipment, Core_ZN_MiscPlug_Equip, !- Name Core_ZN, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 6.78, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} , !- Fraction Latent , !- Fraction Radiant , !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_ZN_1_MiscPlug_Equip, !- Name Perimeter_ZN_1, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 6.78, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} , !- Fraction Latent , !- Fraction Radiant , !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_ZN_2_MiscPlug_Equip, !- Name Perimeter_ZN_2, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 6.78, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} , !- Fraction Latent , !- Fraction Radiant , !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_ZN_3_MiscPlug_Equip, !- Name Perimeter_ZN_3, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 6.78, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} , !- Fraction Latent , !- Fraction Radiant , !- Fraction Lost MiscPlug; !- End-Use Subcategory ElectricEquipment, Perimeter_ZN_4_MiscPlug_Equip, !- Name Perimeter_ZN_4, !- Zone or ZoneList Name BLDG_EQUIP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 6.78, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} , !- Fraction Latent , !- Fraction Radiant , !- Fraction Lost MiscPlug; !- End-Use Subcategory !- =========== ALL OBJECTS IN CLASS: DAYLIGHTING:CONTROLS =========== Daylighting:Controls, Perimeter_ZN_1_DaylCtrl, !- Name Perimeter_ZN_1, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_ZN_1_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 180.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_ZN_1_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.2399, !- Fraction of Zone Controlled by Reference Point 1 377, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_ZN_1_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.0302, !- Fraction of Zone Controlled by Reference Point 2 377; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_ZN_1_DaylRefPt1, !- Name Perimeter_ZN_1, !- Zone Name 9.144000, !- X-Coordinate of Reference Point {m} 1.633700, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_ZN_1_DaylRefPt2, !- Name Perimeter_ZN_1, !- Zone Name 9.144000, !- X-Coordinate of Reference Point {m} 3.267500, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_ZN_2_DaylCtrl, !- Name Perimeter_ZN_2, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_ZN_2_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 90.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_ZN_2_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.2399, !- Fraction of Zone Controlled by Reference Point 1 377, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_ZN_2_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.0302, !- Fraction of Zone Controlled by Reference Point 2 377; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_ZN_2_DaylRefPt1, !- Name Perimeter_ZN_2, !- Zone Name 26.089800, !- X-Coordinate of Reference Point {m} 9.144000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_ZN_2_DaylRefPt2, !- Name Perimeter_ZN_2, !- Zone Name 24.456100, !- X-Coordinate of Reference Point {m} 9.144000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_ZN_3_DaylCtrl, !- Name Perimeter_ZN_3, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_ZN_3_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 0.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_ZN_3_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.2399, !- Fraction of Zone Controlled by Reference Point 1 377, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_ZN_3_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.0302, !- Fraction of Zone Controlled by Reference Point 2 377; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_ZN_3_DaylRefPt1, !- Name Perimeter_ZN_3, !- Zone Name 18.288000, !- X-Coordinate of Reference Point {m} 16.825000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_ZN_3_DaylRefPt2, !- Name Perimeter_ZN_3, !- Zone Name 18.288000, !- X-Coordinate of Reference Point {m} 15.192500, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:Controls, Perimeter_ZN_4_DaylCtrl, !- Name Perimeter_ZN_4, !- Zone Name SplitFlux, !- Daylighting Method , !- Availability Schedule Name Continuousoff, !- Lighting Control Type 0.2, !- Minimum Input Power Fraction for Continuous or ContinuousOff Dimming Control 0.2, !- Minimum Light Output Fraction for Continuous or ContinuousOff Dimming Control 3, !- Number of Stepped Control Steps 1.0, !- Probability Lighting will be Reset When Needed in Manual Stepped Control Perimeter_ZN_4_DaylRefPt1, !- Glare Calculation Daylighting Reference Point Name 270.0, !- Glare Calculation Azimuth Angle of View Direction Clockwise from Zone y-Axis {deg} 22.0, !- Maximum Allowable Discomfort Glare Index , !- DElight Gridding Resolution {m2} Perimeter_ZN_4_DaylRefPt1, !- Daylighting Reference Point 1 Name 0.2399, !- Fraction of Zone Controlled by Reference Point 1 377, !- Illuminance Setpoint at Reference Point 1 {lux} Perimeter_ZN_4_DaylRefPt2, !- Daylighting Reference Point 2 Name 0.0302, !- Fraction of Zone Controlled by Reference Point 2 377; !- Illuminance Setpoint at Reference Point 2 {lux} Daylighting:ReferencePoint, Perimeter_ZN_4_DaylRefPt1, !- Name Perimeter_ZN_4, !- Zone Name 1.633700, !- X-Coordinate of Reference Point {m} 9.144000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} Daylighting:ReferencePoint, Perimeter_ZN_4_DaylRefPt2, !- Name Perimeter_ZN_4, !- Zone Name 3.267500, !- X-Coordinate of Reference Point {m} 9.144000, !- Y-Coordinate of Reference Point {m} 0.762000; !- Z-Coordinate of Reference Point {m} !- =========== ALL OBJECTS IN CLASS: ZONEINFILTRATION =========== ZoneInfiltration:DesignFlowRate, Perimeter_ZN_1_Infiltration, !- Name Perimeter_ZN_1, !- Zone or ZoneList Name INFIL_QUARTER_ON_SCH, !- Schedule Name Flow/ExteriorWallArea, !- Design Flow Rate Calculation Method 0, !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_ZN_1_Door_Infiltration, !- Name Perimeter_ZN_1, !- Zone or ZoneList Name INFIL_Door_Opening_SCH, !- Schedule Name Flow/Zone, !- Design Flow Rate Calculation Method 0.076455414, !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} , !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0., !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_ZN_2_Infiltration, !- Name Perimeter_ZN_2, !- Zone or ZoneList Name INFIL_QUARTER_ON_SCH, !- Schedule Name Flow/ExteriorWallArea, !- Design Flow Rate Calculation Method 0, !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_ZN_3_Infiltration, !- Name Perimeter_ZN_3, !- Zone or ZoneList Name INFIL_QUARTER_ON_SCH, !- Schedule Name Flow/ExteriorWallArea, !- Design Flow Rate Calculation Method 0, !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Perimeter_ZN_4_Infiltration, !- Name Perimeter_ZN_4, !- Zone or ZoneList Name INFIL_QUARTER_ON_SCH, !- Schedule Name Flow/ExteriorWallArea, !- Design Flow Rate Calculation Method 0, !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.00056896, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 0, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.2240, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, Attic_Infiltration, !- Name Attic, !- Zone or ZoneList Name ALWAYS_ON, !- Schedule Name Flow/Zone, !- Design Flow Rate Calculation Method 0.2001, !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} , !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient !- =========== ALL OBJECTS IN CLASS: EXTERIOR:LIGHTS =========== Exterior:Lights, Exterior_Lights_a, !- Name Exterior_lighting_schedule_a, !- Schedule Name 50.7, !- Design Level {W} AstronomicalClock, !- Control Option General; !- End-Use Subcategory Exterior:Lights, Exterior_Lights_b, !- Name Exterior_lighting_schedule_b_2016, !- Schedule Name 115.1, !- Design Level {W} AstronomicalClock, !- Control Option General; !- End-Use Subcategory Exterior:Lights, Exterior_Lights_c, !- Name Exterior_lighting_schedule_c_2016, !- Schedule Name 445.5, !- Design Level {W} AstronomicalClock, !- Control Option General; !- End-Use Subcategory Schedule:Compact, Exterior_lighting_schedule_a, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0, !- Field 3 Until: 24:00,1; !- Field 5 Schedule:Compact, Exterior_lighting_schedule_b, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0.7, !- Field 3 Until: 24:00,1; !- Field 5 Schedule:Compact, Exterior_lighting_schedule_a_IECC2015, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:Weekdays SummerDesignDay, !- Field 2 Until: 07:00,0, !- Field 3 Until: 19:00,1, !- Field 5 Until: 24:00,0, !- Field 7 For:Saturdays, !- Field 9 Until: 24:00,0, !- Field 10 For:AllOtherDays, !- Field 12 Until: 24:00,0; !- Field 13 Schedule:Compact, Exterior_lighting_schedule_b_2016, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0.5, !- Field 3 Until: 24:00,1; !- Field 5 Schedule:Compact, Exterior_lighting_schedule_c_2016, !- Name fraction, !- Schedule Type Limits Name Through:12/31, !- Field 1 For:AllDays, !- Field 2 Until: 06:00,0.5, !- Field 3 Until: 19:00,1, !- Field 5 Until: 24:00,0.5; !- Field 7 !- =========== ALL OBJECTS IN CLASS: SIZING:PARAMETERS =========== Sizing:Parameters, 1.2000, !- Heating Sizing Factor 1.2000, !- Cooling Sizing Factor 6; !- Timesteps in Averaging Window !- =========== ALL OBJECTS IN CLASS: SIZING:ZONE =========== Sizing:Zone, Core_ZN, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Core_ZN, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} ; !- Heating Maximum Air Flow Fraction DesignSpecification:OutdoorAir, SZ DSOA Core_ZN, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_ZN_1, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_ZN_1, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} ; !- Heating Maximum Air Flow Fraction DesignSpecification:OutdoorAir, SZ DSOA Perimeter_ZN_1, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_ZN_2, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_ZN_2, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} ; !- Heating Maximum Air Flow Fraction DesignSpecification:OutdoorAir, SZ DSOA Perimeter_ZN_2, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_ZN_3, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_ZN_3, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} ; !- Heating Maximum Air Flow Fraction DesignSpecification:OutdoorAir, SZ DSOA Perimeter_ZN_3, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Perimeter_ZN_4, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 12.8, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Perimeter_ZN_4, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0.0, !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0.0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} ; !- Heating Maximum Air Flow Fraction DesignSpecification:OutdoorAir, SZ DSOA Perimeter_ZN_4, !- Name Flow/Area, !- Outdoor Air Method , !- Outdoor Air Flow per Person {m3/s-person} 0.000431773, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.0; !- Outdoor Air Flow per Zone {m3/s} !- =========== ALL OBJECTS IN CLASS: SIZING:SYSTEM =========== Sizing:System, PSZ-AC:1, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, PSZ-AC:2, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, PSZ-AC:3, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, PSZ-AC:4, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method Sizing:System, PSZ-AC:5, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 0.3000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 12.8000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} ZoneSum; !- System Outdoor Air Method !- =========== ALL OBJECTS IN CLASS: SIZING:PLANT =========== Sizing:Plant, SHWSys1, !- Plant or Condenser Loop Name Heating, !- Loop Type 48.89, !- Design Loop Exit Temperature {C} 5.0; !- Loop Design Temperature Difference {deltaC} !- =========== ALL OBJECTS IN CLASS: ZONECONTROL:THERMOSTAT =========== ZoneControl:Thermostat, Core_ZN Thermostat, !- Name Core_ZN, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Core_ZN DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_ZN_1 Thermostat, !- Name Perimeter_ZN_1, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_ZN_1 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_ZN_2 Thermostat, !- Name Perimeter_ZN_2, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_ZN_2 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_ZN_3 Thermostat, !- Name Perimeter_ZN_3, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_ZN_3 DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Perimeter_ZN_4 Thermostat, !- Name Perimeter_ZN_4, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Perimeter_ZN_4 DualSPSched; !- Control 1 Name !- =========== ALL OBJECTS IN CLASS: THERMOSTATSETPOINT:DUALSETPOINT =========== ThermostatSetpoint:DualSetpoint, Core_ZN DualSPSched, !- Name HTGSETP_SCH_NO_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_NO_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_ZN_1 DualSPSched, !- Name HTGSETP_SCH_NO_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_NO_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_ZN_2 DualSPSched, !- Name HTGSETP_SCH_NO_OPTIMUM_w_SB, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_NO_OPTIMUM_w_SB; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_ZN_3 DualSPSched, !- Name HTGSETP_SCH_NO_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_NO_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Perimeter_ZN_4 DualSPSched, !- Name HTGSETP_SCH_NO_OPTIMUM, !- Heating Setpoint Temperature Schedule Name CLGSETP_SCH_NO_OPTIMUM; !- Cooling Setpoint Temperature Schedule Name !- =========== ALL OBJECTS IN CLASS: AIRTERMINAL:SINGLEDUCT:UNCONTROLLED =========== AirTerminal:SingleDuct:Uncontrolled, Core_ZN Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Core_ZN Direct Air Inlet Node Name, !- Zone Supply Air Node Name AUTOSIZE; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, Perimeter_ZN_1 Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_ZN_1 Direct Air Inlet Node Name, !- Zone Supply Air Node Name AUTOSIZE; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, Perimeter_ZN_2 Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_ZN_2 Direct Air Inlet Node Name, !- Zone Supply Air Node Name AUTOSIZE; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, Perimeter_ZN_3 Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_ZN_3 Direct Air Inlet Node Name, !- Zone Supply Air Node Name AUTOSIZE; !- Maximum Air Flow Rate {m3/s} AirTerminal:SingleDuct:Uncontrolled, Perimeter_ZN_4 Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Perimeter_ZN_4 Direct Air Inlet Node Name, !- Zone Supply Air Node Name AUTOSIZE; !- Maximum Air Flow Rate {m3/s} !- =========== ALL OBJECTS IN CLASS: ZONEHVAC:EQUIPMENTLIST =========== ZoneHVAC:EquipmentList, Core_ZN Equipment, !- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type Core_ZN Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_ZN_1 Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type Perimeter_ZN_1 Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_ZN_2 Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type Perimeter_ZN_2 Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_ZN_3 Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type Perimeter_ZN_3 Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence ZoneHVAC:EquipmentList, Perimeter_ZN_4 Equipment,!- Name SequentialLoad, !- Load Distribution Scheme AirTerminal:SingleDuct:Uncontrolled, !- Zone Equipment 1 Object Type Perimeter_ZN_4 Direct Air, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1; !- Zone Equipment 1 Heating or No-Load Sequence !- =========== ALL OBJECTS IN CLASS: ZONEHVAC:EQUIPMENTCONNECTIONS =========== ZoneHVAC:EquipmentConnections, Core_ZN, !- Zone Name Core_ZN Equipment, !- Zone Conditioning Equipment List Name Core_ZN Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Core_ZN Air Node, !- Zone Air Node Name Core_ZN Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_ZN_1, !- Zone Name Perimeter_ZN_1 Equipment,!- Zone Conditioning Equipment List Name Perimeter_ZN_1 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_ZN_1 Air Node, !- Zone Air Node Name Perimeter_ZN_1 Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_ZN_2, !- Zone Name Perimeter_ZN_2 Equipment,!- Zone Conditioning Equipment List Name Perimeter_ZN_2 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_ZN_2 Air Node, !- Zone Air Node Name Perimeter_ZN_2 Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_ZN_3, !- Zone Name Perimeter_ZN_3 Equipment,!- Zone Conditioning Equipment List Name Perimeter_ZN_3 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_ZN_3 Air Node, !- Zone Air Node Name Perimeter_ZN_3 Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Perimeter_ZN_4, !- Zone Name Perimeter_ZN_4 Equipment,!- Zone Conditioning Equipment List Name Perimeter_ZN_4 Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Perimeter_ZN_4 Air Node, !- Zone Air Node Name Perimeter_ZN_4 Return Air Node Name; !- Zone Return Air Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: FAN:CONSTANTVOLUME =========== Fan:OnOff, PSZ-AC:1 Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Air Inlet Node Name PSZ-AC:1_Fan-PSZ-AC:1_CoolCNode, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name General; !- End-Use Subcategory Fan:OnOff, PSZ-AC:2 Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Air Inlet Node Name PSZ-AC:2_Fan-PSZ-AC:2_CoolCNode, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name General; !- End-Use Subcategory Fan:OnOff, PSZ-AC:3 Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Air Inlet Node Name PSZ-AC:3_Fan-PSZ-AC:3_CoolCNode, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name General; !- End-Use Subcategory Fan:OnOff, PSZ-AC:4 Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Air Inlet Node Name PSZ-AC:4_Fan-PSZ-AC:4_CoolCNode, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name General; !- End-Use Subcategory Fan:OnOff, PSZ-AC:5 Fan, !- Name HVACOperationSchd, !- Availability Schedule Name 0.55575, !- Fan Total Efficiency 622.5, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.855, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Air Inlet Node Name PSZ-AC:5_Fan-PSZ-AC:5_CoolCNode, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name General; !- End-Use Subcategory !- =========== ALL OBJECTS IN CLASS: COIL:COOLING:DX:SINGLESPEED =========== Coil:Cooling:DX:SingleSpeed, PSZ-AC:1 Heat Pump DX Cooling Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 4.11713235489972, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:1_Fan-PSZ-AC:1_CoolCNode, !- Air Inlet Node Name PSZ-AC:1_CoolC-PSZ-AC:1_HeatCNode, !- Air Outlet Node Name HPACCoolCapFT, !- Total Cooling Capacity Function of Temperature Curve Name HPACCoolCapFFF, !- Total Cooling Capacity Function of Flow Fraction Curve Name HPACCOOLEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACCOOLEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name ; !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} Coil:Cooling:DX:SingleSpeed, PSZ-AC:2 Heat Pump DX Cooling Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 4.11713235489972, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:2_Fan-PSZ-AC:2_CoolCNode, !- Air Inlet Node Name PSZ-AC:2_CoolC-PSZ-AC:2_HeatCNode, !- Air Outlet Node Name HPACCoolCapFT, !- Total Cooling Capacity Function of Temperature Curve Name HPACCoolCapFFF, !- Total Cooling Capacity Function of Flow Fraction Curve Name HPACCOOLEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACCOOLEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name ; !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} Coil:Cooling:DX:SingleSpeed, PSZ-AC:3 Heat Pump DX Cooling Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 4.11713235489972, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:3_Fan-PSZ-AC:3_CoolCNode, !- Air Inlet Node Name PSZ-AC:3_CoolC-PSZ-AC:3_HeatCNode, !- Air Outlet Node Name HPACCoolCapFT, !- Total Cooling Capacity Function of Temperature Curve Name HPACCoolCapFFF, !- Total Cooling Capacity Function of Flow Fraction Curve Name HPACCOOLEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACCOOLEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name ; !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} Coil:Cooling:DX:SingleSpeed, PSZ-AC:4 Heat Pump DX Cooling Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 4.11713235489972, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:4_Fan-PSZ-AC:4_CoolCNode, !- Air Inlet Node Name PSZ-AC:4_CoolC-PSZ-AC:4_HeatCNode, !- Air Outlet Node Name HPACCoolCapFT, !- Total Cooling Capacity Function of Temperature Curve Name HPACCoolCapFFF, !- Total Cooling Capacity Function of Flow Fraction Curve Name HPACCOOLEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACCOOLEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name ; !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} Coil:Cooling:DX:SingleSpeed, PSZ-AC:5 Heat Pump DX Cooling Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 4.11713235489972, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:5_Fan-PSZ-AC:5_CoolCNode, !- Air Inlet Node Name PSZ-AC:5_CoolC-PSZ-AC:5_HeatCNode, !- Air Outlet Node Name HPACCoolCapFT, !- Total Cooling Capacity Function of Temperature Curve Name HPACCoolCapFFF, !- Total Cooling Capacity Function of Flow Fraction Curve Name HPACCOOLEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACCOOLEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name ; !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} !- =========== ALL OBJECTS IN CLASS: COIL:HEATING:DX:SINGLESPEED =========== Coil:Heating:DX:SingleSpeed, PSZ-AC:1 Heat Pump DX Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Heating Capacity {W} 3.3592, !- Gross Rated Heating COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Supply Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:1_CoolC-PSZ-AC:1_HeatCNode, !- Air Inlet Node Name PSZ-AC:1_HeatC-PSZ-AC:1_SuppHeatingNode, !- Air Outlet Node Name HPACHeatCapFT, !- Heating Capacity Function of Temperature Curve Name HPACHeatCapFFF, !- Heating Capacity Function of Flow Fraction Curve Name HPACHeatEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACHeatEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name HPACCOOLEIRFT, !- Defrost Energy Input Ratio Function of Temperature Curve Name -12.2, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} , !- Outdoor Dry-Bulb Temperature to Turn On Compressor {C} 1.67, !- Maximum Outdoor Dry-Bulb Temperature for Defrost Operation {C} 50.0, !- Crankcase Heater Capacity {W} 4.4, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C} ReverseCycle, !- Defrost Strategy OnDemand, !- Defrost Control , !- Defrost Time Period Fraction AUTOSIZE; !- Resistive Defrost Heater Capacity {W} Coil:Heating:DX:SingleSpeed, PSZ-AC:2 Heat Pump DX Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Heating Capacity {W} 3.3592, !- Gross Rated Heating COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Supply Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:2_CoolC-PSZ-AC:2_HeatCNode, !- Air Inlet Node Name PSZ-AC:2_HeatC-PSZ-AC:2_SuppHeatingNode, !- Air Outlet Node Name HPACHeatCapFT, !- Heating Capacity Function of Temperature Curve Name HPACHeatCapFFF, !- Heating Capacity Function of Flow Fraction Curve Name HPACHeatEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACHeatEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name HPACCOOLEIRFT, !- Defrost Energy Input Ratio Function of Temperature Curve Name -12.2, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} , !- Outdoor Dry-Bulb Temperature to Turn On Compressor {C} 1.67, !- Maximum Outdoor Dry-Bulb Temperature for Defrost Operation {C} 50.0, !- Crankcase Heater Capacity {W} 4.4, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C} ReverseCycle, !- Defrost Strategy OnDemand, !- Defrost Control , !- Defrost Time Period Fraction AUTOSIZE; !- Resistive Defrost Heater Capacity {W} Coil:Heating:DX:SingleSpeed, PSZ-AC:3 Heat Pump DX Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Heating Capacity {W} 3.3592, !- Gross Rated Heating COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Supply Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:3_CoolC-PSZ-AC:3_HeatCNode, !- Air Inlet Node Name PSZ-AC:3_HeatC-PSZ-AC:3_SuppHeatingNode, !- Air Outlet Node Name HPACHeatCapFT, !- Heating Capacity Function of Temperature Curve Name HPACHeatCapFFF, !- Heating Capacity Function of Flow Fraction Curve Name HPACHeatEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACHeatEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name HPACCOOLEIRFT, !- Defrost Energy Input Ratio Function of Temperature Curve Name -12.2, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} , !- Outdoor Dry-Bulb Temperature to Turn On Compressor {C} 1.67, !- Maximum Outdoor Dry-Bulb Temperature for Defrost Operation {C} 50.0, !- Crankcase Heater Capacity {W} 4.4, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C} ReverseCycle, !- Defrost Strategy OnDemand, !- Defrost Control , !- Defrost Time Period Fraction AUTOSIZE; !- Resistive Defrost Heater Capacity {W} Coil:Heating:DX:SingleSpeed, PSZ-AC:4 Heat Pump DX Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Heating Capacity {W} 3.3592, !- Gross Rated Heating COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Supply Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:4_CoolC-PSZ-AC:4_HeatCNode, !- Air Inlet Node Name PSZ-AC:4_HeatC-PSZ-AC:4_SuppHeatingNode, !- Air Outlet Node Name HPACHeatCapFT, !- Heating Capacity Function of Temperature Curve Name HPACHeatCapFFF, !- Heating Capacity Function of Flow Fraction Curve Name HPACHeatEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACHeatEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name HPACCOOLEIRFT, !- Defrost Energy Input Ratio Function of Temperature Curve Name -12.2, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} , !- Outdoor Dry-Bulb Temperature to Turn On Compressor {C} 1.67, !- Maximum Outdoor Dry-Bulb Temperature for Defrost Operation {C} 50.0, !- Crankcase Heater Capacity {W} 4.4, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C} ReverseCycle, !- Defrost Strategy OnDemand, !- Defrost Control , !- Defrost Time Period Fraction AUTOSIZE; !- Resistive Defrost Heater Capacity {W} Coil:Heating:DX:SingleSpeed, PSZ-AC:5 Heat Pump DX Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Heating Capacity {W} 3.3592, !- Gross Rated Heating COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Supply Fan Power Per Volume Flow Rate {W/(m3/s)} PSZ-AC:5_CoolC-PSZ-AC:5_HeatCNode, !- Air Inlet Node Name PSZ-AC:5_HeatC-PSZ-AC:5_SuppHeatingNode, !- Air Outlet Node Name HPACHeatCapFT, !- Heating Capacity Function of Temperature Curve Name HPACHeatCapFFF, !- Heating Capacity Function of Flow Fraction Curve Name HPACHeatEIRFT, !- Energy Input Ratio Function of Temperature Curve Name HPACHeatEIRFFF, !- Energy Input Ratio Function of Flow Fraction Curve Name HPACCOOLPLFFPLR, !- Part Load Fraction Correlation Curve Name HPACCOOLEIRFT, !- Defrost Energy Input Ratio Function of Temperature Curve Name -12.2, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C} , !- Outdoor Dry-Bulb Temperature to Turn On Compressor {C} 1.67, !- Maximum Outdoor Dry-Bulb Temperature for Defrost Operation {C} 50.0, !- Crankcase Heater Capacity {W} 4.4, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C} ReverseCycle, !- Defrost Strategy OnDemand, !- Defrost Control , !- Defrost Time Period Fraction AUTOSIZE; !- Resistive Defrost Heater Capacity {W} !- =========== ALL OBJECTS IN CLASS: COIL:HEATING:GAS =========== Coil:Heating:Fuel, PSZ-AC:1 Heat Pump DX Supp Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.81, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} PSZ-AC:1_HeatC-PSZ-AC:1_SuppHeatingNode, !- Air Inlet Node Name PSZ-AC:1 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, PSZ-AC:2 Heat Pump DX Supp Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.81, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} PSZ-AC:2_HeatC-PSZ-AC:2_SuppHeatingNode, !- Air Inlet Node Name PSZ-AC:2 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, PSZ-AC:3 Heat Pump DX Supp Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.81, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} PSZ-AC:3_HeatC-PSZ-AC:3_SuppHeatingNode, !- Air Inlet Node Name PSZ-AC:3 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, PSZ-AC:4 Heat Pump DX Supp Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.81, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} PSZ-AC:4_HeatC-PSZ-AC:4_SuppHeatingNode, !- Air Inlet Node Name PSZ-AC:4 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, PSZ-AC:5 Heat Pump DX Supp Heating Coil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.81, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} PSZ-AC:5_HeatC-PSZ-AC:5_SuppHeatingNode, !- Air Inlet Node Name PSZ-AC:5 Supply Equipment Outlet Node; !- Air Outlet Node Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:UNITARYCOOLONLY =========== AirLoopHVAC:UnitaryHeatPump:AirToAir, PSZ-AC:1_HeatPump, !- Name ALWAYS_ON, !- Availability Schedule Name PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Air Inlet Node Name PSZ-AC:1 Supply Equipment Outlet Node, !- Air Outlet Node Name AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} Core_ZN, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type PSZ-AC:1 Fan, !- Supply Air Fan Name Coil:Heating:DX:SingleSpeed, !- Heating Coil Object Type PSZ-AC:1 Heat Pump DX Heating Coil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type PSZ-AC:1 Heat Pump DX Cooling Coil, !- Cooling Coil Name Coil:Heating:Fuel, !- Supplemental Heating Coil Object Type PSZ-AC:1 Heat Pump DX Supp Heating Coil, !- Supplemental Heating Coil Name AUTOSIZE, !- Maximum Supply Air Temperature from Supplemental Heater {C} 4.44, !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} BlowThrough, !- Fan Placement HVACOperationSchd; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:AirToAir, PSZ-AC:2_HeatPump, !- Name ALWAYS_ON, !- Availability Schedule Name PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Air Inlet Node Name PSZ-AC:2 Supply Equipment Outlet Node, !- Air Outlet Node Name AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} Perimeter_ZN_1, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type PSZ-AC:2 Fan, !- Supply Air Fan Name Coil:Heating:DX:SingleSpeed, !- Heating Coil Object Type PSZ-AC:2 Heat Pump DX Heating Coil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type PSZ-AC:2 Heat Pump DX Cooling Coil, !- Cooling Coil Name Coil:Heating:Fuel, !- Supplemental Heating Coil Object Type PSZ-AC:2 Heat Pump DX Supp Heating Coil, !- Supplemental Heating Coil Name AUTOSIZE, !- Maximum Supply Air Temperature from Supplemental Heater {C} 4.44, !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} BlowThrough, !- Fan Placement HVACOperationSchd; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:AirToAir, PSZ-AC:3_HeatPump, !- Name ALWAYS_ON, !- Availability Schedule Name PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Air Inlet Node Name PSZ-AC:3 Supply Equipment Outlet Node, !- Air Outlet Node Name AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} Perimeter_ZN_2, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type PSZ-AC:3 Fan, !- Supply Air Fan Name Coil:Heating:DX:SingleSpeed, !- Heating Coil Object Type PSZ-AC:3 Heat Pump DX Heating Coil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type PSZ-AC:3 Heat Pump DX Cooling Coil, !- Cooling Coil Name Coil:Heating:Fuel, !- Supplemental Heating Coil Object Type PSZ-AC:3 Heat Pump DX Supp Heating Coil, !- Supplemental Heating Coil Name AUTOSIZE, !- Maximum Supply Air Temperature from Supplemental Heater {C} 4.44, !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} BlowThrough, !- Fan Placement HVACOperationSchd_w_SB; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:AirToAir, PSZ-AC:4_HeatPump, !- Name ALWAYS_ON, !- Availability Schedule Name PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Air Inlet Node Name PSZ-AC:4 Supply Equipment Outlet Node, !- Air Outlet Node Name AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} Perimeter_ZN_3, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type PSZ-AC:4 Fan, !- Supply Air Fan Name Coil:Heating:DX:SingleSpeed, !- Heating Coil Object Type PSZ-AC:4 Heat Pump DX Heating Coil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type PSZ-AC:4 Heat Pump DX Cooling Coil, !- Cooling Coil Name Coil:Heating:Fuel, !- Supplemental Heating Coil Object Type PSZ-AC:4 Heat Pump DX Supp Heating Coil, !- Supplemental Heating Coil Name AUTOSIZE, !- Maximum Supply Air Temperature from Supplemental Heater {C} 4.44, !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} BlowThrough, !- Fan Placement HVACOperationSchd; !- Supply Air Fan Operating Mode Schedule Name AirLoopHVAC:UnitaryHeatPump:AirToAir, PSZ-AC:5_HeatPump, !- Name ALWAYS_ON, !- Availability Schedule Name PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Air Inlet Node Name PSZ-AC:5 Supply Equipment Outlet Node, !- Air Outlet Node Name AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} Perimeter_ZN_4, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Air Fan Object Type PSZ-AC:5 Fan, !- Supply Air Fan Name Coil:Heating:DX:SingleSpeed, !- Heating Coil Object Type PSZ-AC:5 Heat Pump DX Heating Coil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type PSZ-AC:5 Heat Pump DX Cooling Coil, !- Cooling Coil Name Coil:Heating:Fuel, !- Supplemental Heating Coil Object Type PSZ-AC:5 Heat Pump DX Supp Heating Coil, !- Supplemental Heating Coil Name AUTOSIZE, !- Maximum Supply Air Temperature from Supplemental Heater {C} 4.44, !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C} BlowThrough, !- Fan Placement HVACOperationSchd; !- Supply Air Fan Operating Mode Schedule Name !- =========== ALL OBJECTS IN CLASS: CONTROLLER:OUTDOORAIR =========== Controller:OutdoorAir, PSZ-AC:1_OA_Controller, !- Name PSZ-AC:1_OARelief Node, !- Relief Air Outlet Node Name PSZ-AC:1 Supply Equipment Inlet Node, !- Return Air Node Name PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Mixed Air Node Name PSZ-AC:1_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name 0.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, PSZ-AC:2_OA_Controller, !- Name PSZ-AC:2_OARelief Node, !- Relief Air Outlet Node Name PSZ-AC:2 Supply Equipment Inlet Node, !- Return Air Node Name PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Mixed Air Node Name PSZ-AC:2_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name 0.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, PSZ-AC:3_OA_Controller, !- Name PSZ-AC:3_OARelief Node, !- Relief Air Outlet Node Name PSZ-AC:3 Supply Equipment Inlet Node, !- Return Air Node Name PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Mixed Air Node Name PSZ-AC:3_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name 0.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, PSZ-AC:4_OA_Controller, !- Name PSZ-AC:4_OARelief Node, !- Relief Air Outlet Node Name PSZ-AC:4 Supply Equipment Inlet Node, !- Return Air Node Name PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Mixed Air Node Name PSZ-AC:4_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name 0.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name Controller:OutdoorAir, PSZ-AC:5_OA_Controller, !- Name PSZ-AC:5_OARelief Node, !- Relief Air Outlet Node Name PSZ-AC:5 Supply Equipment Inlet Node, !- Return Air Node Name PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Mixed Air Node Name PSZ-AC:5_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name 0.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} LockoutWithHeating, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_MotorizedDamper_Sched; !- Minimum Outdoor Air Schedule Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:CONTROLLERLIST =========== AirLoopHVAC:ControllerList, PSZ-AC:1_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type PSZ-AC:1_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, PSZ-AC:2_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type PSZ-AC:2_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, PSZ-AC:3_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type PSZ-AC:3_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, PSZ-AC:4_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type PSZ-AC:4_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, PSZ-AC:5_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type PSZ-AC:5_OA_Controller; !- Controller 1 Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC =========== AirLoopHVAC, PSZ-AC:1, !- Name , !- Controller List Name PSZ-AC:1 Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} PSZ-AC:1 Air Loop Branches, !- Branch List Name , !- Connector List Name PSZ-AC:1 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name PSZ-AC:1 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name PSZ-AC:1 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names PSZ-AC:1 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, PSZ-AC:2, !- Name , !- Controller List Name PSZ-AC:2 Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} PSZ-AC:2 Air Loop Branches, !- Branch List Name , !- Connector List Name PSZ-AC:2 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name PSZ-AC:2 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name PSZ-AC:2 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names PSZ-AC:2 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, PSZ-AC:3, !- Name , !- Controller List Name PSZ-AC:3 Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} PSZ-AC:3 Air Loop Branches, !- Branch List Name , !- Connector List Name PSZ-AC:3 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name PSZ-AC:3 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name PSZ-AC:3 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names PSZ-AC:3 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, PSZ-AC:4, !- Name , !- Controller List Name PSZ-AC:4 Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} PSZ-AC:4 Air Loop Branches, !- Branch List Name , !- Connector List Name PSZ-AC:4 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name PSZ-AC:4 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name PSZ-AC:4 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names PSZ-AC:4 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, PSZ-AC:5, !- Name , !- Controller List Name PSZ-AC:5 Availability Manager List, !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} PSZ-AC:5 Air Loop Branches, !- Branch List Name , !- Connector List Name PSZ-AC:5 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name PSZ-AC:5 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name PSZ-AC:5 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names PSZ-AC:5 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:OUTDOORAIRSYSTEM:EQUIPMENTLIST =========== AirLoopHVAC:OutdoorAirSystem:EquipmentList, PSZ-AC:1_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type PSZ-AC:1_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, PSZ-AC:2_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type PSZ-AC:2_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, PSZ-AC:3_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type PSZ-AC:3_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, PSZ-AC:4_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type PSZ-AC:4_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, PSZ-AC:5_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type PSZ-AC:5_OAMixing Box; !- Component 1 Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:OUTDOORAIRSYSTEM =========== AirLoopHVAC:OutdoorAirSystem, PSZ-AC:1_OA, !- Name PSZ-AC:1_OA_Controllers, !- Controller List Name PSZ-AC:1_OA_Equipment, !- Outdoor Air Equipment List Name PSZ-AC:1 Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, PSZ-AC:2_OA, !- Name PSZ-AC:2_OA_Controllers, !- Controller List Name PSZ-AC:2_OA_Equipment, !- Outdoor Air Equipment List Name PSZ-AC:2 Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, PSZ-AC:3_OA, !- Name PSZ-AC:3_OA_Controllers, !- Controller List Name PSZ-AC:3_OA_Equipment, !- Outdoor Air Equipment List Name PSZ-AC:3 Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, PSZ-AC:4_OA, !- Name PSZ-AC:4_OA_Controllers, !- Controller List Name PSZ-AC:4_OA_Equipment, !- Outdoor Air Equipment List Name PSZ-AC:4 Availability Manager List; !- Availability Manager List Name AirLoopHVAC:OutdoorAirSystem, PSZ-AC:5_OA, !- Name PSZ-AC:5_OA_Controllers, !- Controller List Name PSZ-AC:5_OA_Equipment, !- Outdoor Air Equipment List Name PSZ-AC:5 Availability Manager List; !- Availability Manager List Name !- =========== ALL OBJECTS IN CLASS: OUTDOORAIR:MIXER =========== OutdoorAir:Mixer, PSZ-AC:1_OAMixing Box, !- Name PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Mixed Air Node Name PSZ-AC:1_OAInlet Node, !- Outdoor Air Stream Node Name PSZ-AC:1_OARelief Node, !- Relief Air Stream Node Name PSZ-AC:1 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, PSZ-AC:2_OAMixing Box, !- Name PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Mixed Air Node Name PSZ-AC:2_OAInlet Node, !- Outdoor Air Stream Node Name PSZ-AC:2_OARelief Node, !- Relief Air Stream Node Name PSZ-AC:2 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, PSZ-AC:3_OAMixing Box, !- Name PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Mixed Air Node Name PSZ-AC:3_OAInlet Node, !- Outdoor Air Stream Node Name PSZ-AC:3_OARelief Node, !- Relief Air Stream Node Name PSZ-AC:3 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, PSZ-AC:4_OAMixing Box, !- Name PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Mixed Air Node Name PSZ-AC:4_OAInlet Node, !- Outdoor Air Stream Node Name PSZ-AC:4_OARelief Node, !- Relief Air Stream Node Name PSZ-AC:4 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, PSZ-AC:5_OAMixing Box, !- Name PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Mixed Air Node Name PSZ-AC:5_OAInlet Node, !- Outdoor Air Stream Node Name PSZ-AC:5_OARelief Node, !- Relief Air Stream Node Name PSZ-AC:5 Supply Equipment Inlet Node; !- Return Air Stream Node Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:ZONESPLITTER =========== AirLoopHVAC:ZoneSplitter, PSZ-AC:1 Supply Air Splitter, !- Name PSZ-AC:1 Zone Equipment Inlet Node, !- Inlet Node Name Core_ZN Direct Air Inlet Node Name; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, PSZ-AC:2 Supply Air Splitter, !- Name PSZ-AC:2 Zone Equipment Inlet Node, !- Inlet Node Name Perimeter_ZN_1 Direct Air Inlet Node Name; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, PSZ-AC:3 Supply Air Splitter, !- Name PSZ-AC:3 Zone Equipment Inlet Node, !- Inlet Node Name Perimeter_ZN_2 Direct Air Inlet Node Name; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, PSZ-AC:4 Supply Air Splitter, !- Name PSZ-AC:4 Zone Equipment Inlet Node, !- Inlet Node Name Perimeter_ZN_3 Direct Air Inlet Node Name; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, PSZ-AC:5 Supply Air Splitter, !- Name PSZ-AC:5 Zone Equipment Inlet Node, !- Inlet Node Name Perimeter_ZN_4 Direct Air Inlet Node Name; !- Outlet 1 Node Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:SUPPLYPATH =========== AirLoopHVAC:SupplyPath, PSZ-AC:1, !- Name PSZ-AC:1 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type PSZ-AC:1 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, PSZ-AC:2, !- Name PSZ-AC:2 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type PSZ-AC:2 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, PSZ-AC:3, !- Name PSZ-AC:3 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type PSZ-AC:3 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, PSZ-AC:4, !- Name PSZ-AC:4 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type PSZ-AC:4 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, PSZ-AC:5, !- Name PSZ-AC:5 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type PSZ-AC:5 Supply Air Splitter; !- Component 1 Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:ZONEMIXER =========== AirLoopHVAC:ZoneMixer, PSZ-AC:1 Return Air Mixer, !- Name PSZ-AC:1 Zone Equipment Outlet Node, !- Outlet Node Name Core_ZN Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, PSZ-AC:2 Return Air Mixer, !- Name PSZ-AC:2 Zone Equipment Outlet Node, !- Outlet Node Name Perimeter_ZN_1 Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, PSZ-AC:3 Return Air Mixer, !- Name PSZ-AC:3 Zone Equipment Outlet Node, !- Outlet Node Name Perimeter_ZN_2 Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, PSZ-AC:4 Return Air Mixer, !- Name PSZ-AC:4 Zone Equipment Outlet Node, !- Outlet Node Name Perimeter_ZN_3 Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, PSZ-AC:5 Return Air Mixer, !- Name PSZ-AC:5 Zone Equipment Outlet Node, !- Outlet Node Name Perimeter_ZN_4 Return Air Node Name; !- Inlet 1 Node Name !- =========== ALL OBJECTS IN CLASS: AIRLOOPHVAC:RETURNPATH =========== AirLoopHVAC:ReturnPath, PSZ-AC:1 Return Air Path,!- Name PSZ-AC:1 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type PSZ-AC:1 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, PSZ-AC:2 Return Air Path,!- Name PSZ-AC:2 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type PSZ-AC:2 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, PSZ-AC:3 Return Air Path,!- Name PSZ-AC:3 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type PSZ-AC:3 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, PSZ-AC:4 Return Air Path,!- Name PSZ-AC:4 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type PSZ-AC:4 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, PSZ-AC:5 Return Air Path,!- Name PSZ-AC:5 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type PSZ-AC:5 Return Air Mixer; !- Component 1 Name !- =========== ALL OBJECTS IN CLASS: BRANCH =========== Branch, PSZ-AC:1 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type PSZ-AC:1_OA, !- Component 1 Name PSZ-AC:1 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:AirToAir, !- Component 2 Object Type PSZ-AC:1_HeatPump, !- Component 2 Name PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Component 2 Inlet Node Name PSZ-AC:1 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, PSZ-AC:2 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type PSZ-AC:2_OA, !- Component 1 Name PSZ-AC:2 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:AirToAir, !- Component 2 Object Type PSZ-AC:2_HeatPump, !- Component 2 Name PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Component 2 Inlet Node Name PSZ-AC:2 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, PSZ-AC:3 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type PSZ-AC:3_OA, !- Component 1 Name PSZ-AC:3 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:AirToAir, !- Component 2 Object Type PSZ-AC:3_HeatPump, !- Component 2 Name PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Component 2 Inlet Node Name PSZ-AC:3 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, PSZ-AC:4 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type PSZ-AC:4_OA, !- Component 1 Name PSZ-AC:4 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:AirToAir, !- Component 2 Object Type PSZ-AC:4_HeatPump, !- Component 2 Name PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Component 2 Inlet Node Name PSZ-AC:4 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, PSZ-AC:5 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type PSZ-AC:5_OA, !- Component 1 Name PSZ-AC:5 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatPump:AirToAir, !- Component 2 Object Type PSZ-AC:5_HeatPump, !- Component 2 Name PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Component 2 Inlet Node Name PSZ-AC:5 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SHWSys1 Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:ConstantSpeed, !- Component 1 Object Type SHWSys1 Pump, !- Component 1 Name SHWSys1 Supply Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Pump-SHWSys1 Water HeaterNodeviaConnector; !- Component 1 Outlet Node Name Branch, SHWSys1 Supply Equipment Branch, !- Name , !- Pressure Drop Curve Name WaterHeater:Mixed, !- Component 1 Object Type SHWSys1 Water Heater, !- Component 1 Name SHWSys1 Pump-SHWSys1 Water HeaterNode, !- Component 1 Inlet Node Name SHWSys1 Supply Equipment Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Supply Equipment Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Supply Equipment Bypass Pipe, !- Component 1 Name SHWSys1 Supply Equip Bypass Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Supply Equip Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Supply Outlet Pipe, !- Component 1 Name SHWSys1 Supply Mixer-SHWSys1 Supply Outlet Pipe, !- Component 1 Inlet Node Name SHWSys1 Supply Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Demand Inlet Pipe, !- Component 1 Name SHWSys1 Demand Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Demand Inlet Pipe-SHWSys1 Demand Mixer; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Load Branch 1, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type Core_ZN Water Equipment, !- Component 1 Name Core_ZN Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name Core_ZN Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Demand Bypass Pipe, !- Component 1 Name SHWSys1 Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name SHWSys1 Demand Bypass Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, SHWSys1 Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SHWSys1 Demand Outlet Pipe, !- Component 1 Name SHWSys1 Demand Mixer-SHWSys1 Demand Outlet Pipe, !- Component 1 Inlet Node Name SHWSys1 Demand Outlet Node; !- Component 1 Outlet Node Name !- =========== ALL OBJECTS IN CLASS: BRANCHLIST =========== BranchList, PSZ-AC:1 Air Loop Branches, !- Name PSZ-AC:1 Air Loop Main Branch; !- Branch 1 Name BranchList, PSZ-AC:2 Air Loop Branches, !- Name PSZ-AC:2 Air Loop Main Branch; !- Branch 1 Name BranchList, PSZ-AC:3 Air Loop Branches, !- Name PSZ-AC:3 Air Loop Main Branch; !- Branch 1 Name BranchList, PSZ-AC:4 Air Loop Branches, !- Name PSZ-AC:4 Air Loop Main Branch; !- Branch 1 Name BranchList, PSZ-AC:5 Air Loop Branches, !- Name PSZ-AC:5 Air Loop Main Branch; !- Branch 1 Name BranchList, SHWSys1 Supply Branches, !- Name SHWSys1 Supply Inlet Branch, !- Branch 1 Name SHWSys1 Supply Equipment Branch, !- Branch 2 Name SHWSys1 Supply Equipment Bypass Branch, !- Branch 3 Name SHWSys1 Supply Outlet Branch; !- Branch 4 Name BranchList, SHWSys1 Demand Branches, !- Name SHWSys1 Demand Inlet Branch, !- Branch 1 Name SHWSys1 Demand Load Branch 1, !- Branch 2 Name SHWSys1 Demand Bypass Branch, !- Branch 3 Name SHWSys1 Demand Outlet Branch; !- Branch 4 Name !- =========== ALL OBJECTS IN CLASS: CONNECTOR:SPLITTER =========== Connector:Splitter, SHWSys1 Supply Splitter, !- Name SHWSys1 Supply Inlet Branch, !- Inlet Branch Name SHWSys1 Supply Equipment Branch, !- Outlet Branch 1 Name SHWSys1 Supply Equipment Bypass Branch; !- Outlet Branch 2 Name Connector:Splitter, SHWSys1 Demand Splitter, !- Name SHWSys1 Demand Inlet Branch, !- Inlet Branch Name SHWSys1 Demand Load Branch 1, !- Outlet Branch 1 Name SHWSys1 Demand Bypass Branch; !- Outlet Branch 2 Name !- =========== ALL OBJECTS IN CLASS: CONNECTOR:MIXER =========== Connector:Mixer, SHWSys1 Supply Mixer, !- Name SHWSys1 Supply Outlet Branch, !- Outlet Branch Name SHWSys1 Supply Equipment Branch, !- Inlet Branch 1 Name SHWSys1 Supply Equipment Bypass Branch; !- Inlet Branch 2 Name Connector:Mixer, SHWSys1 Demand Mixer, !- Name SHWSys1 Demand Outlet Branch, !- Outlet Branch Name SHWSys1 Demand Load Branch 1, !- Inlet Branch 1 Name SHWSys1 Demand Bypass Branch; !- Inlet Branch 2 Name !- =========== ALL OBJECTS IN CLASS: CONNECTORLIST =========== ConnectorList, SHWSys1 Supply Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type SHWSys1 Supply Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type SHWSys1 Supply Mixer; !- Connector 2 Name ConnectorList, SHWSys1 Demand Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type SHWSys1 Demand Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type SHWSys1 Demand Mixer; !- Connector 2 Name !- =========== ALL OBJECTS IN CLASS: NODELIST =========== NodeList, Core_ZN Inlet Nodes, !- Name Core_ZN Direct Air Inlet Node Name; !- Node 1 Name NodeList, Perimeter_ZN_1 Inlet Nodes, !- Name Perimeter_ZN_1 Direct Air Inlet Node Name; !- Node 1 Name NodeList, Perimeter_ZN_2 Inlet Nodes, !- Name Perimeter_ZN_2 Direct Air Inlet Node Name; !- Node 1 Name NodeList, Perimeter_ZN_3 Inlet Nodes, !- Name Perimeter_ZN_3 Direct Air Inlet Node Name; !- Node 1 Name NodeList, Perimeter_ZN_4 Inlet Nodes, !- Name Perimeter_ZN_4 Direct Air Inlet Node Name; !- Node 1 Name NodeList, PSZ-AC:1_OANode List, !- Name PSZ-AC:1_OAInlet Node; !- Node 1 Name NodeList, PSZ-AC:2_OANode List, !- Name PSZ-AC:2_OAInlet Node; !- Node 1 Name NodeList, PSZ-AC:3_OANode List, !- Name PSZ-AC:3_OAInlet Node; !- Node 1 Name NodeList, PSZ-AC:4_OANode List, !- Name PSZ-AC:4_OAInlet Node; !- Node 1 Name NodeList, PSZ-AC:5_OANode List, !- Name PSZ-AC:5_OAInlet Node; !- Node 1 Name !- =========== ALL OBJECTS IN CLASS: OUTDOORAIR:NODE =========== OutdoorAir:Node, PSZ-AC:1_CoolCOA Ref node; !- Name OutdoorAir:Node, PSZ-AC:2_CoolCOA Ref node; !- Name OutdoorAir:Node, PSZ-AC:3_CoolCOA Ref node; !- Name OutdoorAir:Node, PSZ-AC:4_CoolCOA Ref node; !- Name OutdoorAir:Node, PSZ-AC:5_CoolCOA Ref node; !- Name !- =========== ALL OBJECTS IN CLASS: OUTDOORAIR:NODELIST =========== OutdoorAir:NodeList, PSZ-AC:1_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, PSZ-AC:2_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, PSZ-AC:3_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, PSZ-AC:4_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, PSZ-AC:5_OANode List; !- Node or NodeList Name 1 !- =========== ALL OBJECTS IN CLASS: PUMP:CONSTANTSPEED =========== Pump:ConstantSpeed, SHWSys1 Pump, !- Name SHWSys1 Supply Inlet Node, !- Inlet Node Name SHWSys1 Pump-SHWSys1 Water HeaterNodeviaConnector, !- Outlet Node Name autosize, !- Design Flow Rate {m3/s} 0.001, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 0.30, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream Intermittent; !- Pump Control Type !- =========== ALL OBJECTS IN CLASS: WATERHEATER:MIXED =========== WaterHeater:Mixed, SHWSys1 Water Heater, !- Name 0.1514, !- Tank Volume {m3} SHWSys1 Water Heater Setpoint Temperature Schedule, !- Setpoint Temperature Schedule Name 2.0, !- Deadband Temperature Difference {deltaC} 82.2222, !- Maximum Temperature Limit {C} Cycle, !- Heater Control Type 11722.84, !- Heater Maximum Capacity {W} , !- Heater Minimum Capacity {W} , !- Heater Ignition Minimum Flow Rate {m3/s} , !- Heater Ignition Delay {s} electricity, !- Heater Fuel Type 1, !- Heater Thermal Efficiency , !- Part Load Factor Curve Name 571, !- Off Cycle Parasitic Fuel Consumption Rate {W} (SWH Enhancement) August 31, 2012 Specify pipe loss for both Off and On cycle parasitic electricity, !- Off Cycle Parasitic Fuel Type 0.8, !- Off Cycle Parasitic Heat Fraction to Tank 571, !- On Cycle Parasitic Fuel Consumption Rate {W} (SWH Enhancement) July 26, 2012: changed from blank to 309 btu/h (90.56 W) for On Cycle Parasitic load to account for pipe loss electricity, !- On Cycle Parasitic Fuel Type , !- On Cycle Parasitic Heat Fraction to Tank zone, !- Ambient Temperature Indicator , !- Ambient Temperature Schedule Name CORE_ZN, !- Ambient Temperature Zone Name , !- Ambient Temperature Outdoor Air Node Name 1.205980747, !- Off Cycle Loss Coefficient to Ambient Temperature {W/K} , !- Off Cycle Loss Fraction to Zone 1.205980747, !- On Cycle Loss Coefficient to Ambient Temperature {W/K} , !- On Cycle Loss Fraction to Zone 4.048e-06, !- Peak Flow Rate {m3/s} BLDG_SWH_SCH; !- Use Flow Rate Fraction Schedule Name !- =========== ALL OBJECTS IN CLASS: PLANTLOOP =========== PlantLoop, SHWSys1, !- Name Water, !- Fluid Type , !- User Defined Fluid Type SHWSys1 Loop Operation Scheme List, !- Plant Equipment Operation Scheme Name SHWSys1 Supply Outlet Node, !- Loop Temperature Setpoint Node Name 48.89, !- Maximum Loop Temperature {C} 10.0, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0.0, !- Minimum Loop Flow Rate {m3/s} AUTOSIZE, !- Plant Loop Volume {m3} SHWSys1 Supply Inlet Node, !- Plant Side Inlet Node Name SHWSys1 Supply Outlet Node, !- Plant Side Outlet Node Name SHWSys1 Supply Branches, !- Plant Side Branch List Name SHWSys1 Supply Connectors, !- Plant Side Connector List Name SHWSys1 Demand Inlet Node, !- Demand Side Inlet Node Name SHWSys1 Demand Outlet Node, !- Demand Side Outlet Node Name SHWSys1 Demand Branches, !- Demand Side Branch List Name SHWSys1 Demand Connectors, !- Demand Side Connector List Name Optimal; !- Load Distribution Scheme !- =========== ALL OBJECTS IN CLASS: PIPE:ADIABATIC =========== Pipe:Adiabatic, SHWSys1 Supply Equipment Bypass Pipe, !- Name SHWSys1 Supply Equip Bypass Inlet Node, !- Inlet Node Name SHWSys1 Supply Equip Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Supply Outlet Pipe, !- Name SHWSys1 Supply Mixer-SHWSys1 Supply Outlet Pipe, !- Inlet Node Name SHWSys1 Supply Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Demand Inlet Pipe, !- Name SHWSys1 Demand Inlet Node, !- Inlet Node Name SHWSys1 Demand Inlet Pipe-SHWSys1 Demand Mixer; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Demand Bypass Pipe, !- Name SHWSys1 Demand Bypass Pipe Inlet Node, !- Inlet Node Name SHWSys1 Demand Bypass Pipe Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SHWSys1 Demand Outlet Pipe, !- Name SHWSys1 Demand Mixer-SHWSys1 Demand Outlet Pipe, !- Inlet Node Name SHWSys1 Demand Outlet Node; !- Outlet Node Name !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTLIST =========== PlantEquipmentList, SHWSys1 Equipment List, !- Name WaterHeater:Mixed, !- Equipment 1 Object Type SHWSys1 Water Heater; !- Equipment 1 Name !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTOPERATION:HEATINGLOAD =========== PlantEquipmentOperation:HeatingLoad, SHWSys1 Operation Scheme,!- Name 0.0, !- Load Range 1 Lower Limit {W} 1000000000000000, !- Load Range 1 Upper Limit {W} SHWSys1 Equipment List; !- Range 1 Equipment List Name !- =========== ALL OBJECTS IN CLASS: PLANTEQUIPMENTOPERATIONSCHEMES =========== PlantEquipmentOperationSchemes, SHWSys1 Loop Operation Scheme List, !- Name PlantEquipmentOperation:HeatingLoad, !- Control Scheme 1 Object Type SHWSys1 Operation Scheme,!- Control Scheme 1 Name PlantOnSched; !- Control Scheme 1 Schedule Name !- =========== ALL OBJECTS IN CLASS: AVAILABILITYMANAGER:NIGHTCYCLE =========== AvailabilityManager:NightCycle, PSZ-AC:1 Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, PSZ-AC:2 Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, PSZ-AC:3 Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, PSZ-AC:4 Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} AvailabilityManager:NightCycle, PSZ-AC:5 Availability Manager, !- Name Always_On, !- Applicability Schedule Name HVACOperationSchd, !- Fan Schedule Name CycleOnAny, !- Control Type 1.0, !- Thermostat Tolerance {deltaC} FixedRunTime, !- Cycling Run Time Control Type 1800; !- Cycling Run Time {s} !- =========== ALL OBJECTS IN CLASS: AVAILABILITYMANAGERASSIGNMENTLIST =========== AvailabilityManagerAssignmentList, PSZ-AC:1 Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type PSZ-AC:1 Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, PSZ-AC:2 Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type PSZ-AC:2 Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, PSZ-AC:3 Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type PSZ-AC:3 Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, PSZ-AC:4 Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type PSZ-AC:4 Availability Manager; !- Availability Manager 1 Name AvailabilityManagerAssignmentList, PSZ-AC:5 Availability Manager List, !- Name AvailabilityManager:NightCycle, !- Availability Manager 1 Object Type PSZ-AC:5 Availability Manager; !- Availability Manager 1 Name !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:SCHEDULED =========== SetpointManager:Scheduled, SHWSys1 Loop Setpoint Manager, !- Name Temperature, !- Control Variable SHWSys1-Loop-Temp-Schedule, !- Schedule Name SHWSys1 Supply Outlet Node; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:SINGLEZONE:HEATING & COOLING =========== SetpointManager:SingleZone:Heating, SupAirTemp MngrCore_ZN - Htg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Core_ZN, !- Control Zone Name Core_ZN Air Node, !- Zone Node Name Core_ZN Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:1 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, SupAirTemp MngrPerimeter_ZN_1 - Htg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_1, !- Control Zone Name Perimeter_ZN_1 Air Node, !- Zone Node Name Perimeter_ZN_1 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:2 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, SupAirTemp MngrPerimeter_ZN_2 - Htg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_2, !- Control Zone Name Perimeter_ZN_2 Air Node, !- Zone Node Name Perimeter_ZN_2 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:3 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, SupAirTemp MngrPerimeter_ZN_3 - Htg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_3, !- Control Zone Name Perimeter_ZN_3 Air Node, !- Zone Node Name Perimeter_ZN_3 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:4 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Heating, SupAirTemp MngrPerimeter_ZN_4 - Htg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_4, !- Control Zone Name Perimeter_ZN_4 Air Node, !- Zone Node Name Perimeter_ZN_4 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:5 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, SupAirTemp MngrCore_ZN - Clg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Core_ZN, !- Control Zone Name Core_ZN Air Node, !- Zone Node Name Core_ZN Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:1_CoolC-PSZ-AC:1_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, SupAirTemp MngrPerimeter_ZN_1 - Clg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_1, !- Control Zone Name Perimeter_ZN_1 Air Node, !- Zone Node Name Perimeter_ZN_1 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:2_CoolC-PSZ-AC:2_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, SupAirTemp MngrPerimeter_ZN_2 - Clg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_2, !- Control Zone Name Perimeter_ZN_2 Air Node, !- Zone Node Name Perimeter_ZN_2 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:3_CoolC-PSZ-AC:3_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, SupAirTemp MngrPerimeter_ZN_3 - Clg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_3, !- Control Zone Name Perimeter_ZN_3 Air Node, !- Zone Node Name Perimeter_ZN_3 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:4_CoolC-PSZ-AC:4_HeatCNode; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Cooling, SupAirTemp MngrPerimeter_ZN_4 - Clg, !- Name Temperature, !- Control Variable 12.8, !- Minimum Supply Air Temperature {C} 40.0, !- Maximum Supply Air Temperature {C} Perimeter_ZN_4, !- Control Zone Name Perimeter_ZN_4 Air Node, !- Zone Node Name Perimeter_ZN_4 Direct Air Inlet Node Name, !- Zone Inlet Node Name PSZ-AC:5_CoolC-PSZ-AC:5_HeatCNode; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: SETPOINTMANAGER:MIXEDAIR =========== SetpointManager:MixedAir, PSZ-AC:1_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable PSZ-AC:1_CoolC-PSZ-AC:1_HeatCNode, !- Reference Setpoint Node Name PSZ-AC:1_OA-PSZ-AC:1_FanNode, !- Fan Inlet Node Name PSZ-AC:1_Fan-PSZ-AC:1_CoolCNode, !- Fan Outlet Node Name PSZ-AC:1_OA-PSZ-AC:1_FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, PSZ-AC:2_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable PSZ-AC:2_CoolC-PSZ-AC:2_HeatCNode, !- Reference Setpoint Node Name PSZ-AC:2_OA-PSZ-AC:2_FanNode, !- Fan Inlet Node Name PSZ-AC:2_Fan-PSZ-AC:2_CoolCNode, !- Fan Outlet Node Name PSZ-AC:2_OA-PSZ-AC:2_FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, PSZ-AC:3_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable PSZ-AC:3_CoolC-PSZ-AC:3_HeatCNode, !- Reference Setpoint Node Name PSZ-AC:3_OA-PSZ-AC:3_FanNode, !- Fan Inlet Node Name PSZ-AC:3_Fan-PSZ-AC:3_CoolCNode, !- Fan Outlet Node Name PSZ-AC:3_OA-PSZ-AC:3_FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, PSZ-AC:4_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable PSZ-AC:4_CoolC-PSZ-AC:4_HeatCNode, !- Reference Setpoint Node Name PSZ-AC:4_OA-PSZ-AC:4_FanNode, !- Fan Inlet Node Name PSZ-AC:4_Fan-PSZ-AC:4_CoolCNode, !- Fan Outlet Node Name PSZ-AC:4_OA-PSZ-AC:4_FanNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, PSZ-AC:5_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable PSZ-AC:5_CoolC-PSZ-AC:5_HeatCNode, !- Reference Setpoint Node Name PSZ-AC:5_OA-PSZ-AC:5_FanNode, !- Fan Inlet Node Name PSZ-AC:5_Fan-PSZ-AC:5_CoolCNode, !- Fan Outlet Node Name PSZ-AC:5_OA-PSZ-AC:5_FanNode; !- Setpoint Node or NodeList Name !- =========== ALL OBJECTS IN CLASS: WATERUSE:EQUIPMENT =========== WaterUse:Equipment, Core_ZN Water Equipment, !- Name WaterUse, !- End-Use Subcategory 4.048E-06, !- Peak Flow Rate {m3/s} BLDG_SWH_SCH, !- Flow Rate Fraction Schedule Name Core_ZN Water Equipment Temp Sched, !- Target Temperature Schedule Name Core_ZN Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name Core_ZN, !- Zone Name Core_ZN Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Core_ZN Water Equipment Latent fract sched; !- Latent Fraction Schedule Name !- =========== ALL OBJECTS IN CLASS: WATERUSE:CONNECTIONS =========== WaterUse:Connections, Core_ZN Water Equipment, !- Name Core_ZN Water Equipment Water Inlet Node, !- Inlet Node Name Core_ZN Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} Core_ZN Water Equipment; !- Water Use Equipment 1 Name !No PV for this case !- =========== ALL OBJECTS IN CLASS: CURVE:QUADRATIC =========== Curve:Quadratic, PSZ-AC:1_CoolCLennoxStandard10Ton_TGA120S2B_CapFF, !- Name 0.77136, !- Coefficient1 Constant 0.34053, !- Coefficient2 x -0.11088, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:1_CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF, !- Name 1.20550, !- Coefficient1 Constant -0.32953, !- Coefficient2 x 0.12308, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:1_CoolCLennoxStandard10Ton_TGA120S2B_PLR, !- Name 0.77100, !- Coefficient1 Constant 0.22900, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x Curve:Quadratic, PSZ-AC:2_CoolCLennoxStandard10Ton_TGA120S2B_CapFF, !- Name 0.77136, !- Coefficient1 Constant 0.34053, !- Coefficient2 x -0.11088, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:2_CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF, !- Name 1.20550, !- Coefficient1 Constant -0.32953, !- Coefficient2 x 0.12308, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:2_CoolCLennoxStandard10Ton_TGA120S2B_PLR, !- Name 0.77100, !- Coefficient1 Constant 0.22900, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x Curve:Quadratic, PSZ-AC:3_CoolCLennoxStandard10Ton_TGA120S2B_CapFF, !- Name 0.77136, !- Coefficient1 Constant 0.34053, !- Coefficient2 x -0.11088, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:3_CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF, !- Name 1.20550, !- Coefficient1 Constant -0.32953, !- Coefficient2 x 0.12308, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:3_CoolCLennoxStandard10Ton_TGA120S2B_PLR, !- Name 0.77100, !- Coefficient1 Constant 0.22900, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x Curve:Quadratic, PSZ-AC:4_CoolCLennoxStandard10Ton_TGA120S2B_CapFF, !- Name 0.77136, !- Coefficient1 Constant 0.34053, !- Coefficient2 x -0.11088, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:4_CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF, !- Name 1.20550, !- Coefficient1 Constant -0.32953, !- Coefficient2 x 0.12308, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:4_CoolCLennoxStandard10Ton_TGA120S2B_PLR, !- Name 0.77100, !- Coefficient1 Constant 0.22900, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x Curve:Quadratic, PSZ-AC:5_CoolCLennoxStandard10Ton_TGA120S2B_CapFF, !- Name 0.77136, !- Coefficient1 Constant 0.34053, !- Coefficient2 x -0.11088, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:5_CoolCLennoxStandard10Ton_TGA120S2B_EIRFFF, !- Name 1.20550, !- Coefficient1 Constant -0.32953, !- Coefficient2 x 0.12308, !- Coefficient3 x**2 0.75918, !- Minimum Value of x 1.13877; !- Maximum Value of x Curve:Quadratic, PSZ-AC:5_CoolCLennoxStandard10Ton_TGA120S2B_PLR, !- Name 0.77100, !- Coefficient1 Constant 0.22900, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x !- =========== ALL OBJECTS IN CLASS: CURVE:BIQUADRATIC =========== Curve:Biquadratic, PSZ-AC:1_CoolCLennoxStandard10Ton_TGA120S2B_CapFT, !- Name 0.42415, !- Coefficient1 Constant 0.04426, !- Coefficient2 x -0.00042, !- Coefficient3 x**2 0.00333, !- Coefficient4 y -0.00008, !- Coefficient5 y**2 -0.00021, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:1_CoolCLennoxStandard10Ton_TGA120S2B_EIRFT, !- Name 1.23649, !- Coefficient1 Constant -0.02431, !- Coefficient2 x 0.00057, !- Coefficient3 x**2 -0.01434, !- Coefficient4 y 0.00063, !- Coefficient5 y**2 -0.00038, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:2_CoolCLennoxStandard10Ton_TGA120S2B_CapFT, !- Name 0.42415, !- Coefficient1 Constant 0.04426, !- Coefficient2 x -0.00042, !- Coefficient3 x**2 0.00333, !- Coefficient4 y -0.00008, !- Coefficient5 y**2 -0.00021, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:2_CoolCLennoxStandard10Ton_TGA120S2B_EIRFT, !- Name 1.23649, !- Coefficient1 Constant -0.02431, !- Coefficient2 x 0.00057, !- Coefficient3 x**2 -0.01434, !- Coefficient4 y 0.00063, !- Coefficient5 y**2 -0.00038, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:3_CoolCLennoxStandard10Ton_TGA120S2B_CapFT, !- Name 0.42415, !- Coefficient1 Constant 0.04426, !- Coefficient2 x -0.00042, !- Coefficient3 x**2 0.00333, !- Coefficient4 y -0.00008, !- Coefficient5 y**2 -0.00021, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:3_CoolCLennoxStandard10Ton_TGA120S2B_EIRFT, !- Name 1.23649, !- Coefficient1 Constant -0.02431, !- Coefficient2 x 0.00057, !- Coefficient3 x**2 -0.01434, !- Coefficient4 y 0.00063, !- Coefficient5 y**2 -0.00038, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:4_CoolCLennoxStandard10Ton_TGA120S2B_CapFT, !- Name 0.42415, !- Coefficient1 Constant 0.04426, !- Coefficient2 x -0.00042, !- Coefficient3 x**2 0.00333, !- Coefficient4 y -0.00008, !- Coefficient5 y**2 -0.00021, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:4_CoolCLennoxStandard10Ton_TGA120S2B_EIRFT, !- Name 1.23649, !- Coefficient1 Constant -0.02431, !- Coefficient2 x 0.00057, !- Coefficient3 x**2 -0.01434, !- Coefficient4 y 0.00063, !- Coefficient5 y**2 -0.00038, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:5_CoolCLennoxStandard10Ton_TGA120S2B_CapFT, !- Name 0.42415, !- Coefficient1 Constant 0.04426, !- Coefficient2 x -0.00042, !- Coefficient3 x**2 0.00333, !- Coefficient4 y -0.00008, !- Coefficient5 y**2 -0.00021, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y Curve:Biquadratic, PSZ-AC:5_CoolCLennoxStandard10Ton_TGA120S2B_EIRFT, !- Name 1.23649, !- Coefficient1 Constant -0.02431, !- Coefficient2 x 0.00057, !- Coefficient3 x**2 -0.01434, !- Coefficient4 y 0.00063, !- Coefficient5 y**2 -0.00038, !- Coefficient6 x*y 17.00000, !- Minimum Value of x 22.00000, !- Maximum Value of x 29.00000, !- Minimum Value of y 46.00000; !- Maximum Value of y !- =========== ALL OBJECTS IN CLASS: CURVE:QUADRATIC =========== Curve:Quadratic, HPACCoolCapFFF, !- Name 0.8, !- Coefficient1 Constant 0.2, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.5, !- Minimum Value of x 1.5; !- Maximum Value of x Curve:Quadratic, HPACCOOLEIRFFF, !- Name 1.156, !- Coefficient1 Constant -0.1816, !- Coefficient2 x 0.0256, !- Coefficient3 x**2 0.5, !- Minimum Value of x 1.5; !- Maximum Value of x Curve:Quadratic, HPACCOOLPLFFPLR, !- Name 0.85, !- Coefficient1 Constant 0.15, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x Curve:Quadratic, HPACHeatEIRFFF, !- Name 1.3824, !- Coefficient1 Constant -0.4336, !- Coefficient2 x 0.0512, !- Coefficient3 x**2 0.0, !- Minimum Value of x 1.0; !- Maximum Value of x !- =========== ALL OBJECTS IN CLASS: CURVE:CUBIC =========== Curve:Cubic, HPACHeatCapFT, !- Name 0.758746, !- Coefficient1 Constant 0.027626, !- Coefficient2 x 0.000148716, !- Coefficient3 x**2 0.0000034992, !- Coefficient4 x**3 -20.0, !- Minimum Value of x 20.0; !- Maximum Value of x Curve:Cubic, HPACHeatCapFFF, !- Name 0.84, !- Coefficient1 Constant 0.16, !- Coefficient2 x 0.0, !- Coefficient3 x**2 0.0, !- Coefficient4 x**3 0.5, !- Minimum Value of x 1.5; !- Maximum Value of x Curve:Cubic, HPACHeatEIRFT, !- Name 1.19248, !- Coefficient1 Constant -0.0300438, !- Coefficient2 x 0.00103745, !- Coefficient3 x**2 -0.000023328, !- Coefficient4 x**3 -20.0, !- Minimum Value of x 20.0; !- Maximum Value of x !- =========== ALL OBJECTS IN CLASS: CURVE:BIQUADRATIC =========== Curve:Biquadratic, HPACCoolCapFT, !- Name 0.766956, !- Coefficient1 Constant 0.0107756, !- Coefficient2 x -0.0000414703, !- Coefficient3 x**2 0.00134961, !- Coefficient4 y -0.000261144, !- Coefficient5 y**2 0.000457488, !- Coefficient6 x*y 12.77778, !- Minimum Value of x 23.88889, !- Maximum Value of x 21.11111, !- Minimum Value of y 46.11111; !- Maximum Value of y Curve:Biquadratic, HPACCOOLEIRFT, !- Name 0.297145, !- Coefficient1 Constant 0.0430933, !- Coefficient2 x -0.000748766, !- Coefficient3 x**2 0.00597727, !- Coefficient4 y 0.000482112, !- Coefficient5 y**2 -0.000956448, !- Coefficient6 x*y 12.77778, !- Minimum Value of x 23.88889, !- Maximum Value of x 21.11111, !- Minimum Value of y 46.11111; !- Maximum Value of y !- =========== ALL OBJECTS IN CLASS: REPORT METERFILEONLY =========== Output:Meter:MeterFileOnly,Electricity:Facility,Hourly; Output:Meter:MeterFileOnly,ElectricityNet:Facility,Hourly; Output:Meter:MeterFileOnly,Gas:Facility,Hourly; !- =========== ALL OBJECTS IN CLASS: OUTPUTCONTROL:TABLE:STYLE =========== OutputControl:Table:Style, CommaAndHTML; !- Column Separator !- =========== ALL OBJECTS IN CLASS: OUTPUTCONTROL:REPORTINGTOLERANCES =========== OutputControl:ReportingTolerances, 0.556, !- Tolerance for Time Heating Setpoint Not Met {deltaC} 0.556; !- Tolerance for Time Cooling Setpoint Not Met {deltaC} !- =========== ALL OBJECTS IN CLASS: OUTPUT:VARIABLE =========== ! Output:Variable,*,Site Outdoor Air Drybulb Temperature,Hourly; ! Output:Variable,*,Site Outdoor Air Wetbulb Temperature,Hourly; ! Output:Variable,HVACOperationSchd,Schedule Value,Hourly; ! ! ! Outdoor Air Flow ! ! Output:Variable,PSZ-AC:1_OAInlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:2_OAInlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:3_OAInlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:4_OAInlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:5_OAInlet Node,System Node VolFlowRate,Hourly; ! ! ! Return Air Flow ! ! Output:Variable,PSZ-AC:1 Supply Equipment Inlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:2 Supply Equipment Inlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:3 Supply Equipment Inlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:4 Supply Equipment Inlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:5 Supply Equipment Inlet Node,System Node VolFlowRate,Hourly; ! ! ! Return Air Tdb ! ! Output:Variable,PSZ-AC:1 Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:2 Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:3 Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:4 Supply Equipment Inlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:5 Supply Equipment Inlet Node,System Node Temperature,Hourly; ! ! ! Return Air Twb ! ! Output:Variable,PSZ-AC:1 Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:2 Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:3 Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:4 Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:5 Supply Equipment Inlet Node,System Node Wetbulb Temperature,Hourly; ! ! ! supply Air Flow ! ! Output:Variable,PSZ-AC:1 Supply Equipment Outlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:2 Supply Equipment Outlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:3 Supply Equipment Outlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:4 Supply Equipment Outlet Node,System Node VolFlowRate,Hourly; ! Output:Variable,PSZ-AC:5 Supply Equipment Outlet Node,System Node VolFlowRate,Hourly; ! ! ! supply Air Tdb ! ! Output:Variable,PSZ-AC:1 Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:2 Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:3 Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:4 Supply Equipment Outlet Node,System Node Temperature,Hourly; ! Output:Variable,PSZ-AC:5 Supply Equipment Outlet Node,System Node Temperature,Hourly; ! ! ! supply Air Twb ! ! Output:Variable,PSZ-AC:1 Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:2 Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:3 Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:4 Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! Output:Variable,PSZ-AC:5 Supply Equipment Outlet Node,System Node Wetbulb Temperature,Hourly; ! ! ! Coil Load ! ! Output:Variable,*,Air System Cooling Coil Total Cooling Energy,Hourly; ! Output:Variable,*,Air System Heating Coil Total Heating Energy,Hourly; ! ! ! SHW ! ! Output:Variable,*,Water Heater Heating Rate,Hourly; ! ! ! Fan and Pump ! ! Output:Variable,*,Fan Electric Power,hourly; !- HVAC Average W ! Output:Variable,*,Pump Electric Power,hourly; !- HVAC Average W ! Output:Variable,*,Humidifier Electric Power,hourly; !- HVAC Average W ! ! ! Utility and Submeter ! ! Output:Meter,Electricity:Facility,Hourly; ! Output:Meter,Gas:Facility,Hourly; ! Output:Meter,InteriorLights:Electricity,Hourly; ! Output:Meter,ExteriorLights:Electricity,Hourly; ! Output:Meter,InteriorEquipment:Electricity,Hourly; ! Output:Meter,ExteriorEquipment:Electricity,Hourly; ! Output:Meter,Fans:Electricity,Hourly; ! Output:Meter,Pumps:Electricity,Hourly; ! Output:Meter,Heating:Electricity,Hourly; ! Output:Meter,Cooling:Electricity,Hourly; ! Output:Meter,HeatRejection:Electricity,Hourly; ! Output:Meter,Humidifier:Electricity,Hourly; ! Output:Meter,HeatRecovery:Electricity,Hourly; ! Output:Meter,DHW:Electricity,Hourly; ! Output:Meter,Cogeneration:Electricity,Hourly; ! Output:Meter,Refrigeration:Electricity,Hourly; ! Output:Meter,WaterSystems:Electricity,Hourly; ! ! Output:Meter,InteriorLights:Gas,Hourly; ! Output:Meter,ExteriorLights:Gas,Hourly; ! Output:Meter,InteriorEquipment:Gas,Hourly; ! Output:Meter,ExteriorEquipment:Gas,Hourly; ! Output:Meter,Fans:Gas,Hourly; ! Output:Meter,Pumps:Gas,Hourly; ! Output:Meter,Heating:Gas,Hourly; ! Output:Meter,Cooling:Gas,Hourly; ! Output:Meter,HeatRejection:Gas,Hourly; ! Output:Meter,Humidifier:Gas,Hourly; ! Output:Meter,HeatRecovery:Gas,Hourly; ! Output:Meter,DHW:Gas,Hourly; ! Output:Meter,Cogeneration:Gas,Hourly; ! Output:Meter,Refrigeration:Gas,Hourly; ! Output:Meter,WaterSystems:Gas,Hourly; !- =========== ALL OBJECTS IN CLASS: OUTPUT:TABLE:SUMMARYREPORTS =========== Output:Table:SummaryReports, AllSummaryAndMonthly; !- Report 1 Name !- =========== ALL OBJECTS IN CLASS: REPORT:TABLE:MONTHLY =========== Output:Table:Monthly, NameHolderMonthlySummary TaskPurpose ProgressIndicator, !- Name ProgressIndicator,ForDetermination2019, ... 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary CodeName ASHRAE901, !- Name ASHRAE901, ASHRAE1891, IECC, Title24, ORSC, IGCC, ... 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary CodeYear 2019, !- Name all years for ASHRAE90.1, IECC, ASHRAE189.1 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary CodeAmendment NoneAmend, !- Name StateAmend,EEM, NoneAmend for national or state without amendment 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary PrototypeName OfficeSmall, !- Name 16 Prototypes 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary TaskScope National, !- Name National, State, City 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary State National, !- Name National for national analysis, NewYork, Utah,... for state analysis, or city name for city analysis. Spell out the name of the state without space between words 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary ClimateZone 6A, !- Name 0-8 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, NameHolderMonthlySummary RepresentCity USA_MN_Rochester, !- Name representative city like Honolulu for national, for each state, for city analysis. this is not the city of the weather file. The weather city will be extracted from epw file 3, !- Digits After Decimal Site Outdoor Air Drybulb, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating:Gas, !- Variable or Meter 2 Name SumOrAverage; !- Aggregation Type for Variable or Meter 2 EnergyManagementSystem:Sensor, ActualOccupancy, !- Name Binary Occupancy, !- Output:Variable or Output:Meter Index Key Name Schedule Value; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Core_ZN_LSr, !- Name Core_ZN, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Core_ZN_Occ_Sensor, !- Name Core_ZN, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Core_ZN_Area, !- Name Core_ZN, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Core_ZN_Light_Actuator, !- Name Core_ZN_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Core_ZN_Light_EMS_Program, !- Name SET Core_ZN_LSr_IP=0.093*Core_ZN_LSr/Core_ZN_Area, ! Calculate the actual LPD for each hour IF (Core_ZN_Occ_Sensor <= 0) && (Core_ZN_LSr_IP >= 0.02), SET Core_ZN_Light_Actuator = 0.02*Core_ZN_Area/0.09290304, ELSE, SET Core_ZN_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Core_ZN_Light_EMS_Program_Prog_Manager, !- Name BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point SET_Core_ZN_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_ZN_1_LSr, !- Name Perimeter_ZN_1, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_ZN_1_Occ_Sensor, !- Name Perimeter_ZN_1, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_ZN_1_Area, !- Name Perimeter_ZN_1, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_ZN_1_Light_Actuator, !- Name Perimeter_ZN_1_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_ZN_1_Light_EMS_Program, !- Name SET Perimeter_ZN_1_LSr_IP=0.093*Perimeter_ZN_1_LSr/Perimeter_ZN_1_Area, ! Calculate the actual LPD for each hour IF (Perimeter_ZN_1_Occ_Sensor <= 0) && (Perimeter_ZN_1_LSr_IP >= 0.02), SET Perimeter_ZN_1_Light_Actuator = 0.02*Perimeter_ZN_1_Area/0.09290304, ELSE, SET Perimeter_ZN_1_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_ZN_1_Light_EMS_Program_Prog_Manager, !- Name BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point SET_Perimeter_ZN_1_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_ZN_2_LSr, !- Name Perimeter_ZN_2, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_ZN_2_Occ_Sensor, !- Name Perimeter_ZN_2, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_ZN_2_Area, !- Name Perimeter_ZN_2, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_ZN_2_Light_Actuator, !- Name Perimeter_ZN_2_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_ZN_2_Light_EMS_Program, !- Name SET Perimeter_ZN_2_LSr_IP=0.093*Perimeter_ZN_2_LSr/Perimeter_ZN_2_Area, ! Calculate the actual LPD for each hour IF (Perimeter_ZN_2_Occ_Sensor <= 0) && (Perimeter_ZN_2_LSr_IP >= 0.02), IF (ActualOccupancy <= 0), !- Check is to avoid conflict with Add. G SET Perimeter_ZN_2_Light_Actuator = 0.02*Perimeter_ZN_2_Area/0.09290304, ELSE, SET Perimeter_ZN_2_Light_Actuator = NULL, ENDIF, ELSE, SET Perimeter_ZN_2_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_ZN_2_Light_EMS_Program_Prog_Manager, !- Name BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point SET_Perimeter_ZN_2_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_ZN_3_LSr, !- Name Perimeter_ZN_3, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_ZN_3_Occ_Sensor, !- Name Perimeter_ZN_3, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_ZN_3_Area, !- Name Perimeter_ZN_3, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_ZN_3_Light_Actuator, !- Name Perimeter_ZN_3_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_ZN_3_Light_EMS_Program, !- Name SET Perimeter_ZN_3_LSr_IP=0.093*Perimeter_ZN_3_LSr/Perimeter_ZN_3_Area, ! Calculate the actual LPD for each hour IF (Perimeter_ZN_3_Occ_Sensor <= 0) && (Perimeter_ZN_3_LSr_IP >= 0.02), SET Perimeter_ZN_3_Light_Actuator = 0.02*Perimeter_ZN_3_Area/0.09290304, ELSE, SET Perimeter_ZN_3_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_ZN_3_Light_EMS_Program_Prog_Manager, !- Name BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point SET_Perimeter_ZN_3_Light_EMS_Program; !- Program Name 1 EnergyManagementSystem:Sensor, Perimeter_ZN_4_LSr, !- Name Perimeter_ZN_4, !- Output:Variable or Output:Meter Index Key Name Zone Lights Electric Power; !- Output:Variable or Output:Meter Name EnergyManagementSystem:Sensor, Perimeter_ZN_4_Occ_Sensor, !- Name Perimeter_ZN_4, !- Output:Variable or Output:Meter Index Key Name People Occupant Count; !- Output:Variable or Output:Meter Name EnergyManagementSystem:InternalVariable, Perimeter_ZN_4_Area, !- Name Perimeter_ZN_4, !- Internal Data Index Key Name Zone Floor Area; !- Internal Data Type EnergyManagementSystem:Actuator, Perimeter_ZN_4_Light_Actuator, !- Name Perimeter_ZN_4_lights, !- Actuated Component Unique Name Lights, !- Actuated Component Type Electric Power Level; !- Actuated Component Control Type EnergyManagementSystem:Program, SET_Perimeter_ZN_4_Light_EMS_Program, !- Name SET Perimeter_ZN_4_LSr_IP=0.093*Perimeter_ZN_4_LSr/Perimeter_ZN_4_Area, ! Calculate the actual LPD for each hour IF (Perimeter_ZN_4_Occ_Sensor <= 0) && (Perimeter_ZN_4_LSr_IP >= 0.02), SET Perimeter_ZN_4_Light_Actuator = 0.02*Perimeter_ZN_4_Area/0.09290304, ELSE, SET Perimeter_ZN_4_Light_Actuator = NULL, ENDIF; EnergyManagementSystem:ProgramCallingManager, SET_Perimeter_ZN_4_Light_EMS_Program_Prog_Manager, !- Name BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point SET_Perimeter_ZN_4_Light_EMS_Program; !- Program Name 1