mirror of
https://github.com/louisleroy5/trnslator.git
synced 2024-11-15 00:30:31 -05:00
182 lines
9.4 KiB
ReStructuredText
182 lines
9.4 KiB
ReStructuredText
Converting IDF to BUI
|
|
---------------------
|
|
|
|
.. figure:: images/converter@2x.png
|
|
:alt: converter logo
|
|
:width: 100%
|
|
:align: center
|
|
|
|
The necessity of translating IDF files (EnergyPlus_ input files) to BUI files (TRNBuild_ input files) emerged from the
|
|
need of modeling building archetypes [#]_. Knowing that a lot of different models from different sources (NECB_ and US-DOE_)
|
|
have already been developed under EnergyPlus, and it can be a tedious task to create a multizone building in a model
|
|
editor (e.g. TRNBuild), we assume the development of a file translator could be useful for simulationists.
|
|
|
|
Objectives
|
|
..........
|
|
|
|
The principal objectives of this module was to translate (from IDF to BUI) the geometry of the building, the different schedules used in
|
|
the model, and the thermal gains.
|
|
|
|
1. Geometry
|
|
|
|
The building geometry is kept with all the zoning, the different surfaces (construction and windows) and the thermal
|
|
properties of the walls. The thermal properties of windows are not from the IDF, but chosen by the user. The user gives
|
|
a U-value, a SHGC value and Tvis value. Then a window is chosen in the Berkeley Lab library (library used in TRNBuild).
|
|
For more information, see the methodology_ section please.
|
|
|
|
2. Schedules
|
|
|
|
All schedules from the IDF file are translated. The translator is able to process all schedule types defined by
|
|
EnergyPlus (see the different schedule_ types for more information). Only day and week schedules are written in the output
|
|
BUI file
|
|
|
|
3. Gains
|
|
|
|
Internal thermal gains such as “people”, “lights” and “equipment” are translated from the IDF file to the BUI file.
|
|
|
|
4. Conditioning
|
|
|
|
Heating and cooling demands are translated from the IDF file to the BUI file such as power per floor area (W/m²) and a temperature setpoint.
|
|
The temperature set-point is the set-point at the peak time for heating (or cooling).
|
|
|
|
Methodology
|
|
...........
|
|
|
|
The module is divided in 2 major operations. The first one consist in translating the IDF file from EnergyPlus, to an
|
|
IDF file proper to an input file for TRNBuild (T3D file), usually created by the TRNSYS plugin "Trnsys3D_" in SketchUp.
|
|
The second operation is the conversion of the IDF file for TRNBuild to a BUI file done with the executable trnsidf.exe
|
|
(installed by default in the TRNSYS installation folder: `C:TRNSYS18\\Building\\trnsIDF\\`)
|
|
|
|
1. IDF to T3D
|
|
|
|
The conversion from the IDF EnergyPlus file to the IDF TRNBuild file (called here T3D file) is the important part of
|
|
the module, which uses the Eppy_ python package, allowing, with object classes, to find the IDF objects, modify them if
|
|
necessary and re-transcribe them in the T3D file
|
|
|
|
2. T3D to BUI
|
|
|
|
The operation to convert the T3D file to the BUI file is done by running the trnsidf.exe executable with a command
|
|
line. After this operation, the infiltration rate, internal gains and conditioning systems are written in the "REGIME"
|
|
section of each zone in the BUI file.
|
|
|
|
How to convert an IDF file
|
|
..........................
|
|
|
|
Converting an IDF file to a BUI file is done using the terminal with a command line. First, open the Command Prompt on Windows
|
|
or the Terminal on Mac. Note that if you used Anaconda to install python on your machine, you will most likely avoid some issues
|
|
by using the Anaconda Prompt instead.
|
|
|
|
Then simply run the following command:
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert [OPTIONS] IDF_FILE WEATHER_FILE OUTPUT_FOLDER
|
|
|
|
1. ``IDF_FILE`` is the file path of the IDF file to convert. If there are space characters in the path, it should be
|
|
enclosed in quotation marks.
|
|
|
|
2. ``WEATHER_FILE`` is the file path of the weather file to use to run the EnergyPlus simulation. If there are space characters in the path, it should be
|
|
enclosed in quotation marks.
|
|
|
|
3. ``OUTPUT_FOLDER`` is the folder where we want the output folders to be written. If there are space characters in
|
|
the path, it should enclosed in quotation marks. If output folder path is passed, it must exist.
|
|
If nothing is passed, the output folder will be the current working directory.
|
|
|
|
Here is an example. Make sure to replace the last two arguments with the idf file path and the output folder path
|
|
respectively.
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
4. `OPTIONS`: There are different options to the `convert` command. The first 3 manage the requested output files.
|
|
Users can chose to return a combination of flags
|
|
|
|
- if ``-i`` is added, the path to the modified IDF file is returned in the console, and the modified IDF file is
|
|
returned in the output folder. If ``-t`` is added, the path to the T3D file (converted from the IDF file) is
|
|
returned. If ``-d`` is added, the DCK file (TRNSYS input file) is returned in the output folder, and the path to
|
|
this DCK file is returned in the console.
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert -i -t -d "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``--window_lib`` is the path of the window library (W74-lib.dat). This library must be in the same format as the
|
|
Berkeley Lab library used by default in TRNBuild. If nothing is passed, the "W74-lib.dat" file available in the
|
|
package "ressources" folder will be used.
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --window_lib "/Users/Documents/W74-lib.dat" "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``--trnsidf_exe`` is the path of the trnsidf.exe executable. Usually located in the TRNSYS18 folder under
|
|
"Building/trnsIDF/trnsidf.exe".
|
|
If nothing is passed, the following path will be used : "C:TRNSYS18\\Building\\trnsIDF\\trnsidf.exe".
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --trnsidf_exe "C:TRNSYS18\\Building\\trnsIDF\\trnsidf.exe" "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``--template`` is the path of the .d18 template file (usually in the same directory as the `trnsidf.exe` executable).
|
|
If nothing is passed, the following path will be used : "C:TRNSYS18\\Building\\trnsIDF\\NewFileTemplate.d18".
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --template "C:TRNSYS18\\Building\\trnsIDF\\NewFileTemplate.d18" "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``--log_clear_names`` if added, do not print log of "clear_names" (equivalence between old and new names) in
|
|
the console.
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --log_clear_names "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``--window`` specifies the window properties <u_value (W/m²-K)> <shgc (-)> <t_vis (-)> <tolerance (-)> <fframe (-)> <uframe (kJ/m²-K-h)>.
|
|
If nothing is passed, the following values will be used : 2.2 0.65 0.8 0.05 0.15 8.17
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --window 2.2 0.65 0.8 0.05 0.15 8.17 "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``--ordered`` sorts the idf object names
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --ordered "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- If ``--nonum`` is added, do not renumber surfaces in BUI. If ``--batchjob`` or ``-N`` is added, does BatchJob Modus when running trnsidf.exe.
|
|
``--geofloor`` must be followed by a float between 0 and 1, and generates GEOSURF values for distributing direct solar radiation where `geo_floor` % is directed to the floor,
|
|
the rest to walls/windows. If ``--refarea`` is added, updates floor reference area of airnodes. If ``--volume`` is added, updates volume of airnodes.
|
|
If ``--capacitance`` is added, updates capacitance of airnodes. All those options are used when running trnsidf.exe (converting T3D file to BUI file).
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert --nonum -N --geofloor 0.6 --refarea --volume --capacitance "/Users/Documents/NECB 2011 - Warehouse.idf" "/Users/Documents/CAN_PQ_Montreal.Intl.AP.716270_CWEC.epw" "/Users/Documents/WIP"
|
|
|
|
- ``-h`` Shows the "help" message
|
|
|
|
.. code-block:: python
|
|
|
|
trnslator convert -h
|
|
|
|
.. [#] Archetype: building model representing a type of building based on its geometry, thermal properties and its
|
|
usage. Usually used to create urban building model by assigning different archetypes to represent at best the
|
|
building stock we want to model.
|
|
|
|
Equivalence between idf object names when converting a file
|
|
...........................................................
|
|
|
|
.. csv-table:: Equivalences
|
|
:file: ./_static/name_equivalence.csv
|
|
:header-rows: 1
|
|
|
|
|
|
.. _EnergyPlus: https://energyplus.net
|
|
.. _TRNBuild: http://www.trnsys.com/features/suite-of-tools.php
|
|
.. _NECB: https://github.com/canmet-energy/necb_2011_reference_buildings/tree/master/osm_files
|
|
.. _US-DOE: https://www.energycodes.gov/development/commercial/prototype_models
|
|
.. _schedule: https://bigladdersoftware.com/epx/docs/8-9/input-output-reference/group-schedules.html#group-schedules
|
|
.. _Trnsys3D: https://www.trnsys.de/docs/trnsys3d/trnsys3d_uebersicht_en.htm
|
|
.. _Eppy: https://pythonhosted.org/eppy/Main_Tutorial.html
|
|
|