dynamic_building_simulation/data/physics/us_constructions.xml

606 lines
24 KiB
XML
Raw Normal View History

2020-05-18 13:56:54 -04:00
<?xml version="1.0" encoding="utf-8"?>
<library name="us_library">
<windows>
<window type="skylight" id="1" name="189.1-2009 Nonres 4B Skylight without Curb">
<shgc>0.32</shgc>
<frame_ratio units="-">0</frame_ratio>
<thickness units="m">0.003</thickness>
<solar_transmittance_at_normal_incidence units="-">0.301483</solar_transmittance_at_normal_incidence>
<front_side_solar_transmittance_at_normal_incidence units="-">0.648517</front_side_solar_transmittance_at_normal_incidence>
<back_side_solar_transmittance_at_normal_incidence units="-">0.648517</back_side_solar_transmittance_at_normal_incidence>
<conductivity units="W/m K">0.0133144</conductivity>
</window>
<window type="skylight" id="2" name="90.1-2004 Nonres 4B Skylight without Curb">
<shgc>0.49</shgc>
<frame_ratio units="-">0</frame_ratio>
<thickness units="m">0.003</thickness>
<solar_transmittance_at_normal_incidence units="-">0.481761</solar_transmittance_at_normal_incidence>
<front_side_solar_transmittance_at_normal_incidence units="-">0.468239</front_side_solar_transmittance_at_normal_incidence>
<back_side_solar_transmittance_at_normal_incidence units="-">0.468239</back_side_solar_transmittance_at_normal_incidence>
<conductivity units="W/m K">0.03026</conductivity>
</window>
<window type="window" id="3" name="189.1-2009 Nonres 4B Window Nonmetal framing">
<shgc>0.35</shgc>
<frame_ratio units="-">0</frame_ratio>
<thickness units="m">0.003</thickness>
<solar_transmittance_at_normal_incidence units="-">0.328881</solar_transmittance_at_normal_incidence>
<front_side_solar_transmittance_at_normal_incidence units="-">0.621119</front_side_solar_transmittance_at_normal_incidence>
<back_side_solar_transmittance_at_normal_incidence units="-">0.621119</back_side_solar_transmittance_at_normal_incidence>
<conductivity units="W/m K">0.0071399</conductivity>
</window>
<window type="window" id="4" name="90.1-2004 Nonres 4B Window Fixed">
<shgc>0.36</shgc>
<frame_ratio units="-">0</frame_ratio>
<thickness units="m">0.003</thickness>
<solar_transmittance_at_normal_incidence units="-">0.354957</solar_transmittance_at_normal_incidence>
<front_side_solar_transmittance_at_normal_incidence units="-">0.595043</front_side_solar_transmittance_at_normal_incidence>
<back_side_solar_transmittance_at_normal_incidence units="-">0.595043</back_side_solar_transmittance_at_normal_incidence>
<conductivity units="W/m K">0.0134755</conductivity>
</window>
</windows>
<materials>
<material id="1" name="MAT-CC05 8 HW CONCRETE">
<conductivity units="W/m K">1.311</conductivity>
<density units="kg/m3">2240</density>
<specific_heat units="J/kg K">836.8</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="2" name="CP02 CARPET PAD">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.8</visible_absorptance>
</material>
<material id="3" name="Floor Insulation [4]">
<conductivity units="W/m K">0.045</conductivity>
<density units="kg/m3">265</density>
<specific_heat units="J/kg K">836.8</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="4" name="1IN Stucco">
<conductivity units="W/m K">0.6918</conductivity>
<density units="kg/m3">1858</density>
<specific_heat units="J/kg K">837</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.92</solar_absorptance>
<visible_absorptance units="-">0.92</visible_absorptance>
</material>
<material id="5" name="8IN Concrete HW">
<conductivity units="W/m K">1.7296</conductivity>
<density units="kg/m3">2243</density>
<specific_heat units="J/kg K">837</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.65</solar_absorptance>
<visible_absorptance units="-">0.65</visible_absorptance>
</material>
<material id="6" name="Wall Insulation [37]">
<conductivity units="W/m K">0.0432</conductivity>
<density units="kg/m3">91</density>
<specific_heat units="J/kg K">837</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.5</solar_absorptance>
<visible_absorptance units="-">0.5</visible_absorptance>
</material>
<material id="7" name="1/2IN Gypsum">
<conductivity units="W/m K">0.16</conductivity>
<density units="kg/m3">784.9</density>
<specific_heat units="J/kg K">830</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.92</solar_absorptance>
<visible_absorptance units="-">0.92</visible_absorptance>
</material>
<material id="8" name="Wood Siding">
<conductivity units="W/m K">0.11</conductivity>
<density units="kg/m3">544.62</density>
<specific_heat units="J/kg K">1210</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.78</solar_absorptance>
<visible_absorptance units="-">0.78</visible_absorptance>
</material>
<material id="9" name="Wood Shingles">
<conductivity units="W/m K">0.115</conductivity>
<density units="kg/m3">513</density>
<specific_heat units="J/kg K">1255</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.78</solar_absorptance>
<visible_absorptance units="-">0.78</visible_absorptance>
</material>
<material id="10" name="1IN Wood Decking">
<conductivity units="W/m K">0.1211</conductivity>
<density units="kg/m3">593</density>
<specific_heat units="J/kg K">2510</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.78</solar_absorptance>
<visible_absorptance units="-">0.78</visible_absorptance>
</material>
<material id="11" name="Roof Insulation [23]">
<conductivity units="W/m K">0.049</conductivity>
<density units="kg/m3">265</density>
<specific_heat units="J/kg K">836.8</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="12" name="MAT-SHEATH">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="13" name="MAT-SHEATH">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="14" name="Metal Decking">
<conductivity units="W/m K">45.006</conductivity>
<density units="kg/m3">7680</density>
<specific_heat units="J/kg K">418.4</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.3</visible_absorptance>
</material>
<material id="15" name="Roof Membrane">
<conductivity units="W/m K">0.16</conductivity>
<density units="kg/m3">1121.29</density>
<specific_heat units="J/kg K">1460</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="16" name="CP02 CARPET PAD">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.8</visible_absorptance>
</material>
<material id="17" name="MAT-SHEATH">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="18" name="CP02 CARPET PAD">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.8</visible_absorptance>
</material>
<material id="19" name="MAT-SHEATH">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="20" name="CP02 CARPET PAD">
<no_mass>true</no_mass>
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.8</visible_absorptance>
</material>
<material id="21" name="Wall Insulation [38]">
<conductivity units="W/m K">0.045</conductivity>
<density units="kg/m3">265</density>
<specific_heat units="J/kg K">836.8</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.7</solar_absorptance>
<visible_absorptance units="-">0.7</visible_absorptance>
</material>
<material id="22" name="metal siding">
<conductivity units="W/m K">44.96</conductivity>
<density units="kg/m3">7688.86</density>
<specific_heat units="J/kg K">410</specific_heat>
<thermal_absorptance units="-">0.9</thermal_absorptance>
<solar_absorptance units="-">0.2</solar_absorptance>
<visible_absorptance units="-">0.2</visible_absorptance>
</material>
</materials>
<constructions>
<construction type="interior slab" id="1" name="189.1-2009 Nonres 4B Exposed Floor Mass">
<layers>
<layer id="1" name="Layer 1">
<material>3</material>
<thickness units="m">0.0795397</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>1</material>
<thickness units="m">0.20321</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>2</material>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="2" name="189.1-2009 Nonres 4B Ext Wall Mass">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>4</material>
<thickness units="m">0.0253</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>5</material>
<thickness units="m">0.2033</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>6</material>
<thickness units="m">0.0680962</thickness>
</layer>
<layer id="4" name="Layer 4">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="3" name="90.1-2004 Nonres 4B Ext Wall Wood-Framed and Other">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>8</material>
<thickness units="m">0.01</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>3</material>
<thickness units="m">0.0746874</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="roof" id="4" name="189.1-2009 Nonres 4B Roof Attic and Other">
<outside_solar_absorptance units="-">0.78</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.78</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>9</material>
<thickness units="m">0.0178</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>10</material>
<thickness units="m">0.0254</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>11</material>
<thickness units="m">0.375211</thickness>
</layer>
<layer id="4" name="Layer 4">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="roof" id="5" name="90.1-2004 Nonres 4B Roof Attic and Other">
<outside_solar_absorptance units="-">0.78</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.78</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>9</material>
<thickness units="m">0.0178</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>10</material>
<thickness units="m">0.0254</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>11</material>
<thickness units="m">0.221604</thickness>
</layer>
<layer id="4" name="Layer 4">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="6" name="189.1-2009 Nonres 4B Ext Wall Steel-Framed">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>12</material>
</layer>
<layer id="2" name="Layer 2">
<material>3</material>
<thickness units="m">0.118387</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="exterior slab" id="7" name="189.1-2009 Nonres 4B Ext Slab Unheated - 8in Slab without Carpet">
<layers>
<layer id="1" name="Layer 1">
<material>1</material>
<thickness units="m">0.20321</thickness>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="8" name="90.1-2004 Nonres 4B Ext Wall Steel-Framed">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>13</material>
</layer>
<layer id="2" name="Layer 2">
<material>3</material>
<thickness units="m">0.0373223</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="roof" id="9" name="189.1-2009 Nonres 4B Roof IEAD">
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.7</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>15</material>
<thickness units="m">0.0095</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>11</material>
<thickness units="m">0.210538</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>14</material>
<thickness units="m">0.001524</thickness>
</layer>
</layers>
</construction>
<construction type="exterior slab" id="10" name="189.1-2009 Nonres 4B Ext Slab Unheated - 4in Slab without Carpet">
<layers>
<layer id="1" name="Layer 1">
<material>1</material>
<thickness units="m">0.1016</thickness>
</layer>
</layers>
</construction>
<construction type="roof" id="11" name="189.1-2009 Nonres 4B Roof Metal Building">
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.3</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>14</material>
<thickness units="m">0.001524</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>11</material>
<thickness units="m">0.23578</thickness>
</layer>
</layers>
</construction>
<construction type="exterior slab" id="12" name="189.1-2009 Nonres 4B Ext Slab Unheated - 4in Slab with Carpet">
<layers>
<layer id="1" name="Layer 1">
<material>1</material>
<thickness units="m">0.1016</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>16</material>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="13" name="90.1-2004 Nonres 4B Ext Wall Mass">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>4</material>
<thickness units="m">0.0253</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>5</material>
<thickness units="m">0.2033</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>6</material>
<thickness units="m">0.0338606</thickness>
</layer>
<layer id="4" name="Layer 4">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="roof" id="14" name="90.1-2004 Nonres 4B Roof Metal Building">
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.3</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>14</material>
<thickness units="m">0.001524</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>11</material>
<thickness units="m">0.123533</thickness>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="15" name="189.1-2009 Res 4B Ext Wall Steel-Framed">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>17</material>
</layer>
<layer id="2" name="Layer 2">
<material>3</material>
<thickness units="m">0.118387</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="16" name="189.1-2009 Nonres 4B Ext Wall Wood-Framed and Other">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>8</material>
<thickness units="m">0.01</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>3</material>
<thickness units="m">0.110422</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="roof" id="17" name="90.1-2004 Nonres 4B Roof IEAD">
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.7</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>15</material>
<thickness units="m">0.0095</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>11</material>
<thickness units="m">0.124958</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>14</material>
<thickness units="m">0.001524</thickness>
</layer>
</layers>
</construction>
<construction type="interior slab" id="18" name="90.1-2004 Nonres 4B Exposed Floor Mass">
<layers>
<layer id="1" name="Layer 1">
<material>3</material>
<thickness units="m">0.0463846</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>1</material>
<thickness units="m">0.20321</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>18</material>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="19" name="90.1-2004 Res 4B Ext Wall Steel-Framed">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>19</material>
</layer>
<layer id="2" name="Layer 2">
<material>3</material>
<thickness units="m">0.0971136</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="exterior slab" id="20" name="90.1-2004 Nonres 4B Ext Slab Unheated - 8in Slab without Carpet">
<layers>
<layer id="1" name="Layer 1">
<material>1</material>
<thickness units="m">0.20321</thickness>
</layer>
</layers>
</construction>
<construction type="exterior slab" id="21" name="90.1-2004 Nonres 4B Ext Slab Unheated - 4in Slab without Carpet">
<layers>
<layer id="1" name="Layer 1">
<material>1</material>
<thickness units="m">0.1016</thickness>
</layer>
</layers>
</construction>
<construction type="exterior slab" id="22" name="90.1-2004 Nonres 4B Ext Slab Unheated - 4in Slab with Carpet">
<layers>
<layer id="1" name="Layer 1">
<material>1</material>
<thickness units="m">0.1016</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>20</material>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="23" name="189.1-2009 Nonres 4B Ext Wall Metal Building">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>22</material>
<thickness units="m">0.0015</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>21</material>
<thickness units="m">0.139618</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
<construction type="exterior wall" id="24" name="90.1-2004 Nonres 4B Ext Wall Metal Building">
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
<layers>
<layer id="1" name="Layer 1">
<material>22</material>
<thickness units="m">0.0015</thickness>
</layer>
<layer id="2" name="Layer 2">
<material>21</material>
<thickness units="m">0.0598725</thickness>
</layer>
<layer id="3" name="Layer 3">
<material>7</material>
<thickness units="m">0.01271</thickness>
</layer>
</layers>
</construction>
</constructions>
</library>