forked from s_ranjbar/city_retrofit
new catalog model and factory finished and test passed
This commit is contained in:
parent
57ee3e734b
commit
1a7ad20135
|
@ -6,12 +6,14 @@ Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||
"""
|
||||
|
||||
from typing import Union, List
|
||||
from typing import Union, List, TypeVar
|
||||
|
||||
from hub.catalog_factories.data_models.energy_systems.generation_system import GenerationSystem
|
||||
#from hub.catalog_factories.data_models.energy_systems.generation_system import GenerationSystem
|
||||
from hub.catalog_factories.data_models.energy_systems.energy_storage_system import EnergyStorageSystem
|
||||
from hub.catalog_factories.data_models.energy_systems.emission_system import EmissionSystem
|
||||
|
||||
GenerationSystem = TypeVar('GenerationSystem')
|
||||
|
||||
|
||||
class DistributionSystem:
|
||||
"""
|
||||
|
|
|
@ -31,8 +31,8 @@ class MontrealCustomCatalog(Catalog):
|
|||
'demand', 'system_id'))
|
||||
|
||||
self._catalog_generation_equipments = self._load_generation_equipments()
|
||||
self._catalog_distribution_equipments = self._load_distribution_equipments()
|
||||
self._catalog_emission_equipments = self._load_emission_equipments()
|
||||
self._catalog_distribution_equipments = self._load_distribution_equipments()
|
||||
self._catalog_systems = self._load_systems()
|
||||
self._catalog_archetypes = self._load_archetypes()
|
||||
# store the full catalog data model in self._content
|
||||
|
@ -59,10 +59,20 @@ class MontrealCustomCatalog(Catalog):
|
|||
electricity_efficiency = None
|
||||
if 'electrical_efficiency' in equipment:
|
||||
electricity_efficiency = float(equipment['electrical_efficiency'])
|
||||
|
||||
storage_systems = None
|
||||
storage = literal_eval(equipment['storage'].capitalize())
|
||||
if storage:
|
||||
if equipment_type == 'electricity generator':
|
||||
storage_system = ElectricalStorageSystem(equipment_id)
|
||||
else:
|
||||
storage_system = ThermalStorageSystem(equipment_id)
|
||||
storage_systems = [storage_system]
|
||||
if model_name == 'PV system':
|
||||
generation_system = PvGenerationSystem(equipment_id,
|
||||
model_name=model_name,
|
||||
electricity_efficiency=electricity_efficiency,
|
||||
energy_storage_systems=storage_systems
|
||||
)
|
||||
else:
|
||||
generation_system = NonPvGenerationSystem(equipment_id,
|
||||
|
@ -72,14 +82,8 @@ class MontrealCustomCatalog(Catalog):
|
|||
heat_efficiency=heating_efficiency,
|
||||
cooling_efficiency=cooling_efficiency,
|
||||
electricity_efficiency=electricity_efficiency,
|
||||
)
|
||||
storage = literal_eval(equipment['storage'].capitalize())
|
||||
if storage:
|
||||
if equipment_type == 'electricity generator':
|
||||
storage_system = ElectricalStorageSystem(equipment_id)
|
||||
else:
|
||||
storage_system = ThermalStorageSystem(equipment_id)
|
||||
generation_system.energy_storage_systems = [storage_system]
|
||||
energy_storage_systems=storage_systems
|
||||
)
|
||||
_equipments.append(generation_system)
|
||||
|
||||
return _equipments
|
||||
|
@ -102,12 +106,19 @@ class MontrealCustomCatalog(Catalog):
|
|||
distribution_consumption_variable_flow = float(
|
||||
equipment['distribution_consumption_variable_flow']['#text']) / 100
|
||||
|
||||
emission_equipment = equipment['dissipation_id']
|
||||
_emission_equipments = None
|
||||
for equipment_archetype in self._catalog_emission_equipments:
|
||||
if int(equipment_archetype.id) == int(emission_equipment):
|
||||
_emission_equipments = [equipment_archetype]
|
||||
|
||||
distribution_system = DistributionSystem(equipment_id,
|
||||
model_name=model_name,
|
||||
system_type=equipment_type,
|
||||
distribution_consumption_fix_flow=distribution_consumption_fix_flow,
|
||||
distribution_consumption_variable_flow=distribution_consumption_variable_flow,
|
||||
heat_losses=distribution_heat_losses)
|
||||
heat_losses=distribution_heat_losses,
|
||||
emission_systems=_emission_equipments)
|
||||
|
||||
_equipments.append(distribution_system)
|
||||
return _equipments
|
||||
|
@ -148,18 +159,6 @@ class MontrealCustomCatalog(Catalog):
|
|||
for equipment_archetype in self._catalog_distribution_equipments:
|
||||
if int(equipment_archetype.id) == int(distribution_equipment):
|
||||
_distribution_equipments = [equipment_archetype]
|
||||
emission_equipment = system['equipments']['dissipation_id']
|
||||
_emission_equipments = None
|
||||
for equipment_archetype in self._catalog_emission_equipments:
|
||||
if int(equipment_archetype.id) == int(emission_equipment):
|
||||
_emission_equipments = [equipment_archetype]
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
_catalog_systems.append(System(system_id,
|
||||
demands,
|
||||
|
|
|
@ -38,53 +38,96 @@
|
|||
</equipment>
|
||||
</generation_equipments>
|
||||
<distribution_equipments>
|
||||
<equipment id="1" type="Water distribution heating">
|
||||
<equipment id="1" type="Water distribution heating with baseboards">
|
||||
<name>Water distribution heating</name>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="2" type="Water distribution cooling">
|
||||
<equipment id="2" type="Water distribution heating with fan-coils">
|
||||
<name>Water distribution heating</name>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="3" type="Water distribution heating with inductors">
|
||||
<name>Water distribution heating</name>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="4" type="Water distribution cooling with fan-coils">
|
||||
<name>Water distribution cooling</name>
|
||||
<distribution_heat_losses units="%">5</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">4</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="3" type="Central air distribution heating">
|
||||
<equipment id="5" type="Central air distribution heating with fan-coils">
|
||||
<name>Central air distribution heating</name>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="4" type="Central air distribution cooling">
|
||||
<equipment id="6" type="Central air distribution heating with inductors">
|
||||
<name>Central air distribution heating</name>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="7" type="Central air distribution cooling with fan-coils">
|
||||
<name>Central air distribution cooling</name>
|
||||
<distribution_heat_losses units="%">5</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="5" type="Local air distribution heating">
|
||||
<equipment id="8" type="Local air distribution heating with baseboards">
|
||||
<name>Local air distribution heating</name>
|
||||
<distribution_heat_losses units="%">5</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="6" type="Local air distribution cooling">
|
||||
<equipment id="9" type="Local air distribution heating with inductors">
|
||||
<name>Local air distribution heating</name>
|
||||
<distribution_heat_losses units="%">5</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="10" type="Local air distribution cooling with inductors">
|
||||
<name>Local air distribution cooling</name>
|
||||
<distribution_heat_losses units="%">2</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="7" type="Refrigerant distribution">
|
||||
<equipment id="11" type="Refrigerant distribution with fan-coils">
|
||||
<name>Refrigerant distribution</name>
|
||||
<distribution_heat_losses units="%">1</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">1</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="8" type="No distribution">
|
||||
<equipment id="12" type="No distribution with baseboards">
|
||||
<name>No distribution</name>
|
||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
</equipment>
|
||||
<equipment id="13" type="No distribution with inductors">
|
||||
<name>No distribution</name>
|
||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
||||
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
|
||||
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
</equipment>
|
||||
</distribution_equipments>
|
||||
<dissipation_equipments>
|
||||
|
@ -111,7 +154,6 @@
|
|||
<equipments>
|
||||
<generation_id>1</generation_id>
|
||||
<distribution_id>1</distribution_id>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id = "16">
|
||||
|
@ -122,8 +164,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>2</generation_id>
|
||||
<distribution_id>8</distribution_id>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
<distribution_id>12</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id = "2">
|
||||
|
@ -134,8 +175,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>1</generation_id>
|
||||
<distribution_id>1</distribution_id>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
<distribution_id>2</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="3">
|
||||
|
@ -146,8 +186,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>2</generation_id>
|
||||
<distribution_id>1</distribution_id>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
<distribution_id>2</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="4">
|
||||
|
@ -158,9 +197,8 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>3</generation_id>
|
||||
<distribution_id>5</distribution_id>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
</equipments>
|
||||
<distribution_id>8</distribution_id>
|
||||
g </equipments>
|
||||
</system>
|
||||
<system id="5">
|
||||
<name>Single zone packaged rooftop unit with electrical resistance furnace and baseboards and fuel boiler for acs</name>
|
||||
|
@ -170,8 +208,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>4</generation_id>
|
||||
<distribution_id>5</distribution_id>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
<distribution_id>8</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="6">
|
||||
|
@ -183,7 +220,6 @@
|
|||
<equipments>
|
||||
<generation_id>1</generation_id>
|
||||
<distribution_id>1</distribution_id>
|
||||
<dissipation_id>1</dissipation_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="7">
|
||||
|
@ -194,8 +230,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>2</generation_id>
|
||||
<distribution_id>8</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>13</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="8">
|
||||
|
@ -206,8 +241,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>2</generation_id>
|
||||
<distribution_id>1</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>3</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="9">
|
||||
|
@ -218,8 +252,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>2</generation_id>
|
||||
<distribution_id>8</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>13</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="10">
|
||||
|
@ -229,8 +262,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>5</generation_id>
|
||||
<distribution_id>6</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>10</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="11">
|
||||
|
@ -240,8 +272,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>5</generation_id>
|
||||
<distribution_id>2</distribution_id>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
<distribution_id>4</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="12">
|
||||
|
@ -251,8 +282,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>5</generation_id>
|
||||
<distribution_id>6</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>10</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="13">
|
||||
|
@ -262,8 +292,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>5</generation_id>
|
||||
<distribution_id>6</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>10</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="14">
|
||||
|
@ -273,8 +302,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>5</generation_id>
|
||||
<distribution_id>3</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>6</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="15">
|
||||
|
@ -284,8 +312,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>6</generation_id>
|
||||
<distribution_id>5</distribution_id>
|
||||
<dissipation_id>3</dissipation_id>
|
||||
<distribution_id>9</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="17">
|
||||
|
@ -296,8 +323,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>7</generation_id>
|
||||
<distribution_id>3</distribution_id>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
<distribution_id>5</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system id="18">
|
||||
|
@ -307,8 +333,7 @@
|
|||
</demands>
|
||||
<equipments>
|
||||
<generation_id>7</generation_id>
|
||||
<distribution_id>4</distribution_id>
|
||||
<dissipation_id>2</dissipation_id>
|
||||
<distribution_id>7</distribution_id>
|
||||
</equipments>
|
||||
</system>
|
||||
</systems>
|
||||
|
|
|
@ -22,7 +22,7 @@ class TestSystemsCatalog(TestCase):
|
|||
generation_equipments = catalog.names('generation_equipments')
|
||||
self.assertEqual(7, len(generation_equipments['generation_equipments']))
|
||||
distribution_equipments = catalog.names('distribution_equipments')
|
||||
self.assertEqual(8, len(distribution_equipments['distribution_equipments']))
|
||||
self.assertEqual(13, len(distribution_equipments['distribution_equipments']))
|
||||
with self.assertRaises(ValueError):
|
||||
catalog.names('unknown')
|
||||
|
||||
|
|
Loading…
Reference in New Issue
Block a user