forked from s_ranjbar/city_retrofit
finished central data model new structure for energy systems, importer and test
This commit is contained in:
parent
d94bce4174
commit
3f649fd020
@ -754,19 +754,17 @@ class Building(CityObject):
|
|||||||
return None
|
return None
|
||||||
for energy_system in self.energy_systems:
|
for energy_system in self.energy_systems:
|
||||||
generation_systems = energy_system.generation_systems
|
generation_systems = energy_system.generation_systems
|
||||||
print(generation_systems)
|
|
||||||
print(type(generation_systems))
|
|
||||||
for demand_type in energy_system.demand_types:
|
for demand_type in energy_system.demand_types:
|
||||||
if demand_type.lower() == consumption_type.lower():
|
if demand_type.lower() == consumption_type.lower():
|
||||||
if consumption_type in (cte.HEATING, cte.DOMESTIC_HOT_WATER):
|
if consumption_type in (cte.HEATING, cte.DOMESTIC_HOT_WATER):
|
||||||
for generation_system in generation_systems:
|
for generation_system in generation_systems:
|
||||||
coefficient_of_performance = generation_system.generic_generation_system.heat_efficiency
|
coefficient_of_performance = generation_system.heat_efficiency
|
||||||
elif consumption_type == cte.COOLING:
|
elif consumption_type == cte.COOLING:
|
||||||
for generation_system in generation_systems:
|
for generation_system in generation_systems:
|
||||||
coefficient_of_performance = generation_system.generic_generation_system.cooling_efficiency
|
coefficient_of_performance = generation_system.cooling_efficiency
|
||||||
elif consumption_type == cte.ELECTRICITY:
|
elif consumption_type == cte.ELECTRICITY:
|
||||||
for generation_system in generation_systems:
|
for generation_system in generation_systems:
|
||||||
coefficient_of_performance = generation_system.generic_generation_system.electricity_efficiency
|
coefficient_of_performance = generation_system.electricity_efficiency
|
||||||
if coefficient_of_performance == 0:
|
if coefficient_of_performance == 0:
|
||||||
values = [0]*len(demand)
|
values = [0]*len(demand)
|
||||||
final_energy_consumed = values
|
final_energy_consumed = values
|
||||||
@ -797,8 +795,8 @@ class Building(CityObject):
|
|||||||
if self.energy_systems is None:
|
if self.energy_systems is None:
|
||||||
return self._onsite_electrical_production
|
return self._onsite_electrical_production
|
||||||
for energy_system in self.energy_systems:
|
for energy_system in self.energy_systems:
|
||||||
if energy_system.generation_systems.generic_generation_system.type == cte.PHOTOVOLTAIC:
|
if energy_system.generation_systems[0].system_type == cte.PHOTOVOLTAIC:
|
||||||
_efficiency = energy_system.generation_systems.generic_generation_system.electricity_efficiency
|
_efficiency = energy_system.generation_systems[0].electricity_efficiency
|
||||||
self._onsite_electrical_production = {}
|
self._onsite_electrical_production = {}
|
||||||
for _key in self.roofs[0].global_irradiance.keys():
|
for _key in self.roofs[0].global_irradiance.keys():
|
||||||
_results = [0 for _ in range(0, len(self.roofs[0].global_irradiance[_key]))]
|
_results = [0 for _ in range(0, len(self.roofs[0].global_irradiance[_key]))]
|
||||||
|
@ -62,7 +62,6 @@ class City:
|
|||||||
self._level_of_detail = LevelOfDetail()
|
self._level_of_detail = LevelOfDetail()
|
||||||
self._city_objects_dictionary = {}
|
self._city_objects_dictionary = {}
|
||||||
self._city_objects_alias_dictionary = {}
|
self._city_objects_alias_dictionary = {}
|
||||||
self._energy_systems_connection_table = None
|
|
||||||
self._generic_energy_systems = None
|
self._generic_energy_systems = None
|
||||||
|
|
||||||
def _get_location(self) -> Location:
|
def _get_location(self) -> Location:
|
||||||
@ -505,24 +504,6 @@ class City:
|
|||||||
"""
|
"""
|
||||||
return self._level_of_detail
|
return self._level_of_detail
|
||||||
|
|
||||||
@property
|
|
||||||
def energy_systems_connection_table(self) -> Union[None, DataFrame]:
|
|
||||||
"""
|
|
||||||
Get energy systems connection table which includes at least two columns: energy_system_type and associated_building
|
|
||||||
and may also include dimensioned_energy_system and connection_building_to_dimensioned_energy_system
|
|
||||||
:return: DataFrame
|
|
||||||
"""
|
|
||||||
return self._energy_systems_connection_table
|
|
||||||
|
|
||||||
@energy_systems_connection_table.setter
|
|
||||||
def energy_systems_connection_table(self, value):
|
|
||||||
"""
|
|
||||||
Set energy systems connection table which includes at least two columns: energy_system_type and associated_building
|
|
||||||
and may also include dimensioned_energy_system and connection_building_to_dimensioned_energy_system
|
|
||||||
:param value: DataFrame
|
|
||||||
"""
|
|
||||||
self._energy_systems_connection_table = value
|
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def generic_energy_systems(self) -> dict:
|
def generic_energy_systems(self) -> dict:
|
||||||
"""
|
"""
|
||||||
|
@ -5,7 +5,12 @@ Copyright © 2023 Concordia CERC group
|
|||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_distribution_system import GenericDistributionSystem
|
from typing import Union, List, TypeVar
|
||||||
|
|
||||||
|
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
||||||
|
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
|
||||||
|
|
||||||
|
GenerationSystem = TypeVar('GenerationSystem')
|
||||||
|
|
||||||
|
|
||||||
class DistributionSystem:
|
class DistributionSystem:
|
||||||
@ -13,20 +18,158 @@ class DistributionSystem:
|
|||||||
DistributionSystem class
|
DistributionSystem class
|
||||||
"""
|
"""
|
||||||
def __init__(self):
|
def __init__(self):
|
||||||
self._generic_distribution_system = None
|
self._model_name = None
|
||||||
|
self._type = None
|
||||||
|
self._supply_temperature = None
|
||||||
|
self._distribution_consumption_fix_flow = None
|
||||||
|
self._distribution_consumption_variable_flow = None
|
||||||
|
self._heat_losses = None
|
||||||
|
self._generation_systems = None
|
||||||
|
self._energy_storage_systems = None
|
||||||
|
self._emission_systems = None
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def generic_distribution_system(self) -> GenericDistributionSystem:
|
def model_name(self):
|
||||||
"""
|
"""
|
||||||
Get generic_distribution_system
|
Get model name
|
||||||
:return: GenericDistributionSystem
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_distribution_system
|
return self._model_name
|
||||||
|
|
||||||
@generic_distribution_system.setter
|
@model_name.setter
|
||||||
def generic_distribution_system(self, value):
|
def model_name(self, value):
|
||||||
"""
|
"""
|
||||||
Set associated generic_distribution_system
|
Set model name
|
||||||
:param value: GenericDistributionSystem
|
:param value: string
|
||||||
"""
|
"""
|
||||||
self._generic_distribution_system = value
|
self._model_name = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def type(self):
|
||||||
|
"""
|
||||||
|
Get type from [air, water, refrigerant]
|
||||||
|
:return: string
|
||||||
|
"""
|
||||||
|
return self._type
|
||||||
|
|
||||||
|
@type.setter
|
||||||
|
def type(self, value):
|
||||||
|
"""
|
||||||
|
Set type from [air, water, refrigerant]
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._type = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def supply_temperature(self):
|
||||||
|
"""
|
||||||
|
Get supply_temperature in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._supply_temperature
|
||||||
|
|
||||||
|
@supply_temperature.setter
|
||||||
|
def supply_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set supply_temperature in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._supply_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def distribution_consumption_fix_flow(self):
|
||||||
|
"""
|
||||||
|
Get distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._distribution_consumption_fix_flow
|
||||||
|
|
||||||
|
@distribution_consumption_fix_flow.setter
|
||||||
|
def distribution_consumption_fix_flow(self, value):
|
||||||
|
"""
|
||||||
|
Set distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
self._distribution_consumption_fix_flow = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def distribution_consumption_variable_flow(self):
|
||||||
|
"""
|
||||||
|
Get distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
|
||||||
|
over energy produced (J/J)
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._distribution_consumption_variable_flow
|
||||||
|
|
||||||
|
@distribution_consumption_variable_flow.setter
|
||||||
|
def distribution_consumption_variable_flow(self, value):
|
||||||
|
"""
|
||||||
|
Set distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
|
||||||
|
over energy produced (J/J)
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
self._distribution_consumption_variable_flow = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def heat_losses(self):
|
||||||
|
"""
|
||||||
|
Get heat_losses in ratio over energy produced
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._heat_losses
|
||||||
|
|
||||||
|
@heat_losses.setter
|
||||||
|
def heat_losses(self, value):
|
||||||
|
"""
|
||||||
|
Set heat_losses in ratio over energy produced
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._heat_losses = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def generation_systems(self) -> Union[None, List[GenerationSystem]]:
|
||||||
|
"""
|
||||||
|
Get generation systems connected to the distribution system
|
||||||
|
:return: [GenerationSystem]
|
||||||
|
"""
|
||||||
|
return self._generation_systems
|
||||||
|
|
||||||
|
@generation_systems.setter
|
||||||
|
def generation_systems(self, value):
|
||||||
|
"""
|
||||||
|
Set generation systems connected to the distribution system
|
||||||
|
:param value: [GenerationSystem]
|
||||||
|
"""
|
||||||
|
self._generation_systems = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def energy_storage_systems(self) -> Union[None, List[EnergyStorageSystem]]:
|
||||||
|
"""
|
||||||
|
Get energy storage systems connected to this distribution system
|
||||||
|
:return: [EnergyStorageSystem]
|
||||||
|
"""
|
||||||
|
return self._energy_storage_systems
|
||||||
|
|
||||||
|
@energy_storage_systems.setter
|
||||||
|
def energy_storage_systems(self, value):
|
||||||
|
"""
|
||||||
|
Set energy storage systems connected to this distribution system
|
||||||
|
:param value: [EnergyStorageSystem]
|
||||||
|
"""
|
||||||
|
self._energy_storage_systems = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def emission_systems(self) -> Union[None, List[EmissionSystem]]:
|
||||||
|
"""
|
||||||
|
Get energy emission systems connected to this distribution system
|
||||||
|
:return: [EmissionSystem]
|
||||||
|
"""
|
||||||
|
return self._emission_systems
|
||||||
|
|
||||||
|
@emission_systems.setter
|
||||||
|
def emission_systems(self, value):
|
||||||
|
"""
|
||||||
|
Set energy emission systems connected to this distribution system
|
||||||
|
:param value: [EmissionSystem]
|
||||||
|
"""
|
||||||
|
self._emission_systems = value
|
||||||
|
@ -1,83 +1,32 @@
|
|||||||
"""
|
"""
|
||||||
Energy System catalog heat generation system
|
Electrical storage system
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
|
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||||
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from __future__ import annotations
|
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_storage_system import GenericStorageSystem
|
|
||||||
|
|
||||||
|
|
||||||
|
class ElectricalStorageSystem(EnergyStorageSystem):
|
||||||
class ElectricalStorageSystem:
|
""""
|
||||||
"""
|
Electrical Storage System Class
|
||||||
Electrical Storage system class
|
|
||||||
"""
|
"""
|
||||||
|
|
||||||
def __init__(self):
|
def __init__(self):
|
||||||
self._model_name = None
|
|
||||||
self._manufacturer = None
|
super().__init__()
|
||||||
self._generic_storage_system = None
|
|
||||||
self._rated_output_power = None
|
self._rated_output_power = None
|
||||||
self._nominal_efficiency = None
|
self._nominal_efficiency = None
|
||||||
self._battery_voltage = None
|
self._battery_voltage = None
|
||||||
self._depth_of_discharge = None
|
self._depth_of_discharge = None
|
||||||
self._self_discharge_rate = None
|
self._self_discharge_rate = None
|
||||||
|
|
||||||
@property
|
|
||||||
def model_name(self):
|
|
||||||
"""
|
|
||||||
Get the model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._model_name
|
|
||||||
|
|
||||||
@model_name.setter
|
|
||||||
def model_name(self, value):
|
|
||||||
"""
|
|
||||||
Set the model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
self._model_name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def manufacturer(self):
|
|
||||||
"""
|
|
||||||
Get the manufacturer name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._manufacturer
|
|
||||||
|
|
||||||
@manufacturer.setter
|
|
||||||
def manufacturer(self, value):
|
|
||||||
"""
|
|
||||||
Set the manufacturer name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
self._manufacturer = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generic_storage_system(self) -> GenericStorageSystem:
|
|
||||||
"""
|
|
||||||
Get associated generic_storage_system
|
|
||||||
:return: GenericStorageSystem
|
|
||||||
"""
|
|
||||||
return self._generic_storage_system
|
|
||||||
|
|
||||||
@generic_storage_system.setter
|
|
||||||
def generic_storage_system(self, value):
|
|
||||||
"""
|
|
||||||
Set associated generic_storage_system
|
|
||||||
:param value: GenericStorageSystem
|
|
||||||
"""
|
|
||||||
self._generic_storage_system = value
|
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def rated_output_power(self):
|
def rated_output_power(self):
|
||||||
"""
|
"""
|
||||||
Get the rated output power in Watts
|
Get the rated output power of storage system in Watts
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._rated_output_power
|
return self._rated_output_power
|
||||||
@ -85,15 +34,15 @@ class ElectricalStorageSystem:
|
|||||||
@rated_output_power.setter
|
@rated_output_power.setter
|
||||||
def rated_output_power(self, value):
|
def rated_output_power(self, value):
|
||||||
"""
|
"""
|
||||||
Set the rated output power in Watts
|
Set the rated output power of storage system in Watts
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._rated_output_power = value
|
self._rated_output_power = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def nominal_efficiency(self):
|
def nominal_efficiency(self):
|
||||||
"""
|
"""
|
||||||
Get the nominal efficiency
|
Get the nominal efficiency of the storage system
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._nominal_efficiency
|
return self._nominal_efficiency
|
||||||
@ -101,8 +50,8 @@ class ElectricalStorageSystem:
|
|||||||
@nominal_efficiency.setter
|
@nominal_efficiency.setter
|
||||||
def nominal_efficiency(self, value):
|
def nominal_efficiency(self, value):
|
||||||
"""
|
"""
|
||||||
Set the nominal efficiency
|
Set the nominal efficiency of the storage system
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._nominal_efficiency = value
|
self._nominal_efficiency = value
|
||||||
|
|
||||||
@ -117,8 +66,8 @@ class ElectricalStorageSystem:
|
|||||||
@battery_voltage.setter
|
@battery_voltage.setter
|
||||||
def battery_voltage(self, value):
|
def battery_voltage(self, value):
|
||||||
"""
|
"""
|
||||||
Get the battery voltage in Volts
|
Set the battery voltage in Volts
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._battery_voltage = value
|
self._battery_voltage = value
|
||||||
|
|
||||||
@ -134,7 +83,7 @@ class ElectricalStorageSystem:
|
|||||||
def depth_of_discharge(self, value):
|
def depth_of_discharge(self, value):
|
||||||
"""
|
"""
|
||||||
Set the depth of discharge as a percentage
|
Set the depth of discharge as a percentage
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._depth_of_discharge = value
|
self._depth_of_discharge = value
|
||||||
|
|
||||||
@ -149,7 +98,7 @@ class ElectricalStorageSystem:
|
|||||||
@self_discharge_rate.setter
|
@self_discharge_rate.setter
|
||||||
def self_discharge_rate(self, value):
|
def self_discharge_rate(self, value):
|
||||||
"""
|
"""
|
||||||
Get the self discharge rate of battery as a percentage
|
Set the self discharge rate of battery as a percentage
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._self_discharge_rate = value
|
self._self_discharge_rate = value
|
||||||
|
@ -1,32 +1,64 @@
|
|||||||
"""
|
"""
|
||||||
Energy emission system definition
|
Emission system module
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_emission_system import GenericEmissionSystem
|
|
||||||
|
|
||||||
|
|
||||||
class EmissionSystem:
|
class EmissionSystem:
|
||||||
"""
|
"""
|
||||||
EmissionSystem class
|
EmissionSystem class
|
||||||
"""
|
"""
|
||||||
def __init__(self):
|
def __init__(self):
|
||||||
self._generic_emission_system = None
|
self._model_name = None
|
||||||
|
self._type = None
|
||||||
|
self._parasitic_energy_consumption = None
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def generic_emission_system(self) -> GenericEmissionSystem:
|
def model_name(self):
|
||||||
"""
|
"""
|
||||||
Get associated generic_emission_system
|
Get model name
|
||||||
:return: GenericEmissionSystem
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_emission_system
|
return self._model_name
|
||||||
|
|
||||||
@generic_emission_system.setter
|
@model_name.setter
|
||||||
def generic_emission_system(self, value):
|
def model_name(self, value):
|
||||||
"""
|
"""
|
||||||
Set associated
|
Set model name
|
||||||
:param value: GenericEmissionSystem
|
:param value: string
|
||||||
"""
|
"""
|
||||||
self._generic_emission_system = value
|
self._model_name = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def type(self):
|
||||||
|
"""
|
||||||
|
Get type
|
||||||
|
:return: string
|
||||||
|
"""
|
||||||
|
return self._type
|
||||||
|
|
||||||
|
@type.setter
|
||||||
|
def type(self, value):
|
||||||
|
"""
|
||||||
|
Set type
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._type = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def parasitic_energy_consumption(self):
|
||||||
|
"""
|
||||||
|
Get parasitic_energy_consumption in ratio (W/W)
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._parasitic_energy_consumption
|
||||||
|
|
||||||
|
@parasitic_energy_consumption.setter
|
||||||
|
def parasitic_energy_consumption(self, value):
|
||||||
|
"""
|
||||||
|
Set parasitic_energy_consumption in ratio (W/W)
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._parasitic_energy_consumption = value
|
||||||
|
@ -1,9 +1,9 @@
|
|||||||
"""
|
"""
|
||||||
Energy storage system
|
Energy storage system. Abstract class
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from abc import ABC
|
from abc import ABC
|
||||||
@ -13,8 +13,13 @@ class EnergyStorageSystem(ABC):
|
|||||||
"""
|
"""
|
||||||
Energy storage System class
|
Energy storage System class
|
||||||
"""
|
"""
|
||||||
def __init__(self, generic_storage_system):
|
def __init__(self):
|
||||||
self._generic_storage_system = generic_storage_system
|
self._type_energy_stored = None
|
||||||
|
self._storage_type = None
|
||||||
|
self._model_name = None
|
||||||
|
self._manufacturer = None
|
||||||
|
self._nominal_capacity = None
|
||||||
|
self._losses_ratio = None
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def type_energy_stored(self):
|
def type_energy_stored(self):
|
||||||
@ -22,7 +27,15 @@ class EnergyStorageSystem(ABC):
|
|||||||
Get type of energy stored from ['electrical', 'thermal']
|
Get type of energy stored from ['electrical', 'thermal']
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system.type_energy_stored
|
return self._type_energy_stored
|
||||||
|
|
||||||
|
@type_energy_stored.setter
|
||||||
|
def type_energy_stored(self, value):
|
||||||
|
"""
|
||||||
|
Set type of energy stored from ['electrical', 'thermal']
|
||||||
|
:return: string
|
||||||
|
"""
|
||||||
|
self._type_energy_stored = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def storage_type(self):
|
def storage_type(self):
|
||||||
@ -30,7 +43,15 @@ class EnergyStorageSystem(ABC):
|
|||||||
Get storage type
|
Get storage type
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system.storage_type
|
return self._storage_type
|
||||||
|
|
||||||
|
@storage_type.setter
|
||||||
|
def storage_type(self, value):
|
||||||
|
"""
|
||||||
|
Get storage type
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._storage_type = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def model_name(self):
|
def model_name(self):
|
||||||
@ -38,7 +59,15 @@ class EnergyStorageSystem(ABC):
|
|||||||
Get system model
|
Get system model
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system.model_name
|
return self._model_name
|
||||||
|
|
||||||
|
@model_name.setter
|
||||||
|
def model_name(self, value):
|
||||||
|
"""
|
||||||
|
Set system model
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._model_name = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def manufacturer(self):
|
def manufacturer(self):
|
||||||
@ -46,7 +75,15 @@ class EnergyStorageSystem(ABC):
|
|||||||
Get name of manufacturer
|
Get name of manufacturer
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system.manufacturer
|
return self._manufacturer
|
||||||
|
|
||||||
|
@manufacturer.setter
|
||||||
|
def manufacturer(self, value):
|
||||||
|
"""
|
||||||
|
Set name of manufacturer
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._manufacturer = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def nominal_capacity(self):
|
def nominal_capacity(self):
|
||||||
@ -54,7 +91,15 @@ class EnergyStorageSystem(ABC):
|
|||||||
Get the nominal capacity of storage systems in Jules
|
Get the nominal capacity of storage systems in Jules
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system.nominal_capacity
|
return self._nominal_capacity
|
||||||
|
|
||||||
|
@nominal_capacity.setter
|
||||||
|
def nominal_capacity(self, value):
|
||||||
|
"""
|
||||||
|
Set the nominal capacity of storage systems in Jules
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
self._nominal_capacity = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def losses_ratio(self):
|
def losses_ratio(self):
|
||||||
@ -62,4 +107,12 @@ class EnergyStorageSystem(ABC):
|
|||||||
Get the losses-ratio of storage system in Jules lost / Jules stored
|
Get the losses-ratio of storage system in Jules lost / Jules stored
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system.losses_ratio
|
return self._losses_ratio
|
||||||
|
|
||||||
|
@losses_ratio.setter
|
||||||
|
def losses_ratio(self, value):
|
||||||
|
"""
|
||||||
|
Set the losses-ratio of storage system in Jules lost / Jules stored
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
self._losses_ratio = value
|
||||||
|
@ -6,9 +6,10 @@ Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|||||||
"""
|
"""
|
||||||
|
|
||||||
from typing import Union, List
|
from typing import Union, List
|
||||||
|
from pathlib import Path
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
|
||||||
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
||||||
|
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||||
from hub.city_model_structure.energy_systems.control_system import ControlSystem
|
from hub.city_model_structure.energy_systems.control_system import ControlSystem
|
||||||
from hub.city_model_structure.city_object import CityObject
|
from hub.city_model_structure.city_object import CityObject
|
||||||
|
|
||||||
@ -17,28 +18,46 @@ class EnergySystem:
|
|||||||
"""
|
"""
|
||||||
EnergySystem class
|
EnergySystem class
|
||||||
"""
|
"""
|
||||||
def __init__(self, generic_energy_system):
|
def __init__(self):
|
||||||
self._generic_energy_system = generic_energy_system
|
self._demand_types = None
|
||||||
|
self._name = None
|
||||||
self._generation_systems = None
|
self._generation_systems = None
|
||||||
self._distribution_systems = None
|
self._distribution_systems = None
|
||||||
|
self._configuration_schema = None
|
||||||
self._connected_city_objects = None
|
self._connected_city_objects = None
|
||||||
self._control_system = None
|
self._control_system = None
|
||||||
|
|
||||||
@property
|
|
||||||
def name(self):
|
|
||||||
"""
|
|
||||||
Get energy system name
|
|
||||||
:return: str
|
|
||||||
"""
|
|
||||||
return self._generic_energy_system.name
|
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def demand_types(self):
|
def demand_types(self):
|
||||||
"""
|
"""
|
||||||
Get demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
|
Get demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
|
||||||
:return: [string]
|
:return: [string]
|
||||||
"""
|
"""
|
||||||
return self._generic_energy_system.demand_types
|
return self._demand_types
|
||||||
|
|
||||||
|
@demand_types.setter
|
||||||
|
def demand_types(self, value):
|
||||||
|
"""
|
||||||
|
Set demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
|
||||||
|
:param value: [string]
|
||||||
|
"""
|
||||||
|
self._demand_types = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def name(self):
|
||||||
|
"""
|
||||||
|
Get energy system name
|
||||||
|
:return: str
|
||||||
|
"""
|
||||||
|
return self._name
|
||||||
|
|
||||||
|
@name.setter
|
||||||
|
def name(self, value):
|
||||||
|
"""
|
||||||
|
Set energy system name
|
||||||
|
:param value:
|
||||||
|
"""
|
||||||
|
self._name = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def generation_systems(self) -> List[GenerationSystem]:
|
def generation_systems(self) -> List[GenerationSystem]:
|
||||||
@ -52,7 +71,7 @@ class EnergySystem:
|
|||||||
def generation_systems(self, value):
|
def generation_systems(self, value):
|
||||||
"""
|
"""
|
||||||
Set generation systems
|
Set generation systems
|
||||||
:param value: [GenerationSystem]
|
:return: [GenerationSystem]
|
||||||
"""
|
"""
|
||||||
self._generation_systems = value
|
self._generation_systems = value
|
||||||
|
|
||||||
@ -72,6 +91,22 @@ class EnergySystem:
|
|||||||
"""
|
"""
|
||||||
self._distribution_systems = value
|
self._distribution_systems = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def configuration_schema(self) -> Path:
|
||||||
|
"""
|
||||||
|
Get the schema of the system configuration
|
||||||
|
:return: Path
|
||||||
|
"""
|
||||||
|
return self._configuration_schema
|
||||||
|
|
||||||
|
@configuration_schema.setter
|
||||||
|
def configuration_schema(self, value):
|
||||||
|
"""
|
||||||
|
Set the schema of the system configuration
|
||||||
|
:param value: Path
|
||||||
|
"""
|
||||||
|
self._configuration_schema = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def connected_city_objects(self) -> Union[None, List[CityObject]]:
|
def connected_city_objects(self) -> Union[None, List[CityObject]]:
|
||||||
"""
|
"""
|
||||||
|
@ -1,8 +1,9 @@
|
|||||||
"""
|
"""
|
||||||
Energy generation system definition
|
Energy generation system (abstract class)
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
|
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from __future__ import annotations
|
from __future__ import annotations
|
||||||
@ -17,10 +18,13 @@ class GenerationSystem(ABC):
|
|||||||
"""
|
"""
|
||||||
GenerationSystem class
|
GenerationSystem class
|
||||||
"""
|
"""
|
||||||
def __init__(self, generic_generation_system):
|
def __init__(self):
|
||||||
self._generic_generation_system = generic_generation_system
|
self._system_type = None
|
||||||
|
self._model_name = None
|
||||||
|
self._manufacturer = None
|
||||||
|
self._fuel_type = None
|
||||||
self._distribution_systems = None
|
self._distribution_systems = None
|
||||||
self._storage_systems = None
|
self._energy_storage_systems = None
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def system_type(self):
|
def system_type(self):
|
||||||
@ -28,23 +32,47 @@ class GenerationSystem(ABC):
|
|||||||
Get type
|
Get type
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_generation_system.system_type
|
return self._system_type
|
||||||
|
|
||||||
|
@system_type.setter
|
||||||
|
def system_type(self, value):
|
||||||
|
"""
|
||||||
|
Set type
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._system_type = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def model_name(self):
|
def model_name(self):
|
||||||
"""
|
"""
|
||||||
Get the model name
|
Get model name
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_generation_system.model_name
|
return self._model_name
|
||||||
|
|
||||||
|
@model_name.setter
|
||||||
|
def model_name(self, value):
|
||||||
|
"""
|
||||||
|
Set model name
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._model_name = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def manufacturer(self):
|
def manufacturer(self):
|
||||||
"""
|
"""
|
||||||
Get the manufacturer name
|
Get manufacturer's name
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_generation_system.manufacturer
|
return self._manufacturer
|
||||||
|
|
||||||
|
@manufacturer.setter
|
||||||
|
def manufacturer(self, value):
|
||||||
|
"""
|
||||||
|
Set manufacturer's name
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._manufacturer = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def fuel_type(self):
|
def fuel_type(self):
|
||||||
@ -52,13 +80,21 @@ class GenerationSystem(ABC):
|
|||||||
Get fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
|
Get fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
|
||||||
:return: string
|
:return: string
|
||||||
"""
|
"""
|
||||||
return self._generic_generation_system.fuel_type
|
return self._fuel_type
|
||||||
|
|
||||||
|
@fuel_type.setter
|
||||||
|
def fuel_type(self, value):
|
||||||
|
"""
|
||||||
|
Set fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._fuel_type = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
|
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
|
||||||
"""
|
"""
|
||||||
Get distributions systems connected to this generation system
|
Get distributions systems connected to this generation system
|
||||||
:return: [GenericDistributionSystem]
|
:return: [DistributionSystem]
|
||||||
"""
|
"""
|
||||||
return self._distribution_systems
|
return self._distribution_systems
|
||||||
|
|
||||||
@ -71,17 +107,17 @@ class GenerationSystem(ABC):
|
|||||||
self._distribution_systems = value
|
self._distribution_systems = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def storage_systems(self) -> Union[None, List[EnergyStorageSystem]]:
|
def energy_storage_systems(self) -> Union[None, List[EnergyStorageSystem]]:
|
||||||
"""
|
"""
|
||||||
Get energy storage systems connected to this generation system
|
Get energy storage systems connected to this generation system
|
||||||
:return: [EnergyStorageSystem]
|
:return: [EnergyStorageSystem]
|
||||||
"""
|
"""
|
||||||
return self._storage_systems
|
return self._energy_storage_systems
|
||||||
|
|
||||||
@storage_systems.setter
|
@energy_storage_systems.setter
|
||||||
def storage_systems(self, value):
|
def energy_storage_systems(self, value):
|
||||||
"""
|
"""
|
||||||
Set energy storage systems connected to this generation system
|
Set energy storage systems connected to this generation system
|
||||||
:param value: [EnergyStorageSystem]
|
:param value: [EnergyStorageSystem]
|
||||||
"""
|
"""
|
||||||
self._storage_systems = value
|
self._energy_storage_systems = value
|
||||||
|
@ -1,175 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic energy distribution system definition
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from typing import Union, List, TypeVar
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_emission_system import GenericEmissionSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_storage_system import GenericStorageSystem
|
|
||||||
|
|
||||||
GenericGenerationSystem = TypeVar('GenericGenerationSystem')
|
|
||||||
|
|
||||||
|
|
||||||
class GenericDistributionSystem:
|
|
||||||
"""
|
|
||||||
GenericDistributionSystem class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
self._model_name = None
|
|
||||||
self._type = None
|
|
||||||
self._supply_temperature = None
|
|
||||||
self._distribution_consumption_fix_flow = None
|
|
||||||
self._distribution_consumption_variable_flow = None
|
|
||||||
self._heat_losses = None
|
|
||||||
self._generic_generation_systems = None
|
|
||||||
self._generic_storage_systems = None
|
|
||||||
self._generic_emission_systems = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def model_name(self):
|
|
||||||
"""
|
|
||||||
Get model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._model_name
|
|
||||||
|
|
||||||
@model_name.setter
|
|
||||||
def model_name(self, value):
|
|
||||||
"""
|
|
||||||
Set model name
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._model_name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def type(self):
|
|
||||||
"""
|
|
||||||
Get type from [air, water, refrigerant]
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._type
|
|
||||||
|
|
||||||
@type.setter
|
|
||||||
def type(self, value):
|
|
||||||
"""
|
|
||||||
Set type from [air, water, refrigerant]
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._type = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get supply_temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._supply_temperature
|
|
||||||
|
|
||||||
@supply_temperature.setter
|
|
||||||
def supply_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set supply_temperature in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._supply_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def distribution_consumption_fix_flow(self):
|
|
||||||
"""
|
|
||||||
Get distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._distribution_consumption_fix_flow
|
|
||||||
|
|
||||||
@distribution_consumption_fix_flow.setter
|
|
||||||
def distribution_consumption_fix_flow(self, value):
|
|
||||||
"""
|
|
||||||
Set distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
self._distribution_consumption_fix_flow = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def distribution_consumption_variable_flow(self):
|
|
||||||
"""
|
|
||||||
Get distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
|
|
||||||
over energy produced (J/J)
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._distribution_consumption_variable_flow
|
|
||||||
|
|
||||||
@distribution_consumption_variable_flow.setter
|
|
||||||
def distribution_consumption_variable_flow(self, value):
|
|
||||||
"""
|
|
||||||
Set distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
|
|
||||||
over energy produced (J/J)
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
self._distribution_consumption_variable_flow = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_losses(self):
|
|
||||||
"""
|
|
||||||
Get heat_losses in ratio over energy produced
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._heat_losses
|
|
||||||
|
|
||||||
@heat_losses.setter
|
|
||||||
def heat_losses(self, value):
|
|
||||||
"""
|
|
||||||
Set heat_losses in ratio over energy produced
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._heat_losses = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generic_generation_systems(self) -> Union[None, List[GenericGenerationSystem]]:
|
|
||||||
"""
|
|
||||||
Get generation systems connected to the distribution system
|
|
||||||
:return: [generic_generation_systems]
|
|
||||||
"""
|
|
||||||
return self._generic_generation_systems
|
|
||||||
|
|
||||||
@generic_generation_systems.setter
|
|
||||||
def generic_generation_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set generation systems connected to the distribution system
|
|
||||||
:param value: [generic_generation_systems]
|
|
||||||
"""
|
|
||||||
self._generic_generation_systems = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generic_storage_systems(self) -> Union[None, List[GenericStorageSystem]]:
|
|
||||||
"""
|
|
||||||
Get energy storage systems connected to this distribution system
|
|
||||||
:return: [GenericStorageSystem]
|
|
||||||
"""
|
|
||||||
return self._generic_storage_systems
|
|
||||||
|
|
||||||
@generic_storage_systems.setter
|
|
||||||
def generic_storage_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set energy storage systems connected to this distribution system
|
|
||||||
:param value: [GenericStorageSystem]
|
|
||||||
"""
|
|
||||||
self._generic_storage_systems = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generic_emission_systems(self) -> Union[None, List[GenericEmissionSystem]]:
|
|
||||||
"""
|
|
||||||
Get energy emission systems connected to this distribution system
|
|
||||||
:return: [GenericEmissionSystem]
|
|
||||||
"""
|
|
||||||
return self._generic_emission_systems
|
|
||||||
|
|
||||||
@generic_emission_systems.setter
|
|
||||||
def generic_emission_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set energy emission systems connected to this distribution system
|
|
||||||
:param value: [GenericEmissionSystem]
|
|
||||||
"""
|
|
||||||
self._generic_emission_systems = value
|
|
@ -1,104 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic electrical storage system
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_storage_system import GenericStorageSystem
|
|
||||||
|
|
||||||
|
|
||||||
class GenericElectricalStorageSystem(GenericStorageSystem):
|
|
||||||
""""
|
|
||||||
Generic Electrical Storage System Class
|
|
||||||
"""
|
|
||||||
|
|
||||||
def __init__(self):
|
|
||||||
|
|
||||||
super().__init__()
|
|
||||||
self._rated_output_power = None
|
|
||||||
self._nominal_efficiency = None
|
|
||||||
self._battery_voltage = None
|
|
||||||
self._depth_of_discharge = None
|
|
||||||
self._self_discharge_rate = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def rated_output_power(self):
|
|
||||||
"""
|
|
||||||
Get the rated output power of storage system in Watts
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._rated_output_power
|
|
||||||
|
|
||||||
@rated_output_power.setter
|
|
||||||
def rated_output_power(self, value):
|
|
||||||
"""
|
|
||||||
Set the rated output power of storage system in Watts
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._rated_output_power = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get the nominal efficiency of the storage system
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_efficiency
|
|
||||||
|
|
||||||
@nominal_efficiency.setter
|
|
||||||
def nominal_efficiency(self, value):
|
|
||||||
"""
|
|
||||||
Set the nominal efficiency of the storage system
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_efficiency = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def battery_voltage(self):
|
|
||||||
"""
|
|
||||||
Get the battery voltage in Volts
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._battery_voltage
|
|
||||||
|
|
||||||
@battery_voltage.setter
|
|
||||||
def battery_voltage(self, value):
|
|
||||||
"""
|
|
||||||
Set the battery voltage in Volts
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._battery_voltage = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def depth_of_discharge(self):
|
|
||||||
"""
|
|
||||||
Get the depth of discharge as a percentage
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._depth_of_discharge
|
|
||||||
|
|
||||||
@depth_of_discharge.setter
|
|
||||||
def depth_of_discharge(self, value):
|
|
||||||
"""
|
|
||||||
Set the depth of discharge as a percentage
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._depth_of_discharge = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def self_discharge_rate(self):
|
|
||||||
"""
|
|
||||||
Get the self discharge rate of battery as a percentage
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._self_discharge_rate
|
|
||||||
|
|
||||||
@self_discharge_rate.setter
|
|
||||||
def self_discharge_rate(self, value):
|
|
||||||
"""
|
|
||||||
Set the self discharge rate of battery as a percentage
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._self_discharge_rate = value
|
|
@ -1,64 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic energy emission system module
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
|
|
||||||
class GenericEmissionSystem:
|
|
||||||
"""
|
|
||||||
GenericEmissionSystem class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
self._model_name = None
|
|
||||||
self._type = None
|
|
||||||
self._parasitic_energy_consumption = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def model_name(self):
|
|
||||||
"""
|
|
||||||
Get model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._model_name
|
|
||||||
|
|
||||||
@model_name.setter
|
|
||||||
def model_name(self, value):
|
|
||||||
"""
|
|
||||||
Set model name
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._model_name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def type(self):
|
|
||||||
"""
|
|
||||||
Get type
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._type
|
|
||||||
|
|
||||||
@type.setter
|
|
||||||
def type(self, value):
|
|
||||||
"""
|
|
||||||
Set type
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._type = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def parasitic_energy_consumption(self):
|
|
||||||
"""
|
|
||||||
Get parasitic_energy_consumption in ratio (W/W)
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._parasitic_energy_consumption
|
|
||||||
|
|
||||||
@parasitic_energy_consumption.setter
|
|
||||||
def parasitic_energy_consumption(self, value):
|
|
||||||
"""
|
|
||||||
Set parasitic_energy_consumption in ratio (W/W)
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._parasitic_energy_consumption = value
|
|
@ -1,104 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic energy system definition
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from typing import Union, List
|
|
||||||
from pathlib import Path
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_distribution_system import GenericDistributionSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
|
|
||||||
|
|
||||||
|
|
||||||
class GenericEnergySystem:
|
|
||||||
"""
|
|
||||||
GenericEnergySystem class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
self._demand_types = None
|
|
||||||
self._name = None
|
|
||||||
self._generation_systems = None
|
|
||||||
self._distribution_systems = None
|
|
||||||
self._configuration_schema = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def demand_types(self):
|
|
||||||
"""
|
|
||||||
Get demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
|
|
||||||
:return: [string]
|
|
||||||
"""
|
|
||||||
return self._demand_types
|
|
||||||
|
|
||||||
@demand_types.setter
|
|
||||||
def demand_types(self, value):
|
|
||||||
"""
|
|
||||||
Set demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
|
|
||||||
:param value: [string]
|
|
||||||
"""
|
|
||||||
self._demand_types = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def name(self):
|
|
||||||
"""
|
|
||||||
Get energy system name
|
|
||||||
:return: str
|
|
||||||
"""
|
|
||||||
return self._name
|
|
||||||
|
|
||||||
@name.setter
|
|
||||||
def name(self, value):
|
|
||||||
"""
|
|
||||||
Set energy system name
|
|
||||||
:param value:
|
|
||||||
"""
|
|
||||||
self._name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generation_systems(self) -> List[GenericGenerationSystem]:
|
|
||||||
"""
|
|
||||||
Get generation systems
|
|
||||||
:return: [GenerationSystem]
|
|
||||||
"""
|
|
||||||
return self._generation_systems
|
|
||||||
|
|
||||||
@generation_systems.setter
|
|
||||||
def generation_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set generation systems
|
|
||||||
:return: [GenerationSystem]
|
|
||||||
"""
|
|
||||||
self._generation_systems = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def distribution_systems(self) -> Union[None, List[GenericDistributionSystem]]:
|
|
||||||
"""
|
|
||||||
Get distribution systems
|
|
||||||
:return: [DistributionSystem]
|
|
||||||
"""
|
|
||||||
return self._distribution_systems
|
|
||||||
|
|
||||||
@distribution_systems.setter
|
|
||||||
def distribution_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set distribution systems
|
|
||||||
:param value: [DistributionSystem]
|
|
||||||
"""
|
|
||||||
self._distribution_systems = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def configuration_schema(self) -> Path:
|
|
||||||
"""
|
|
||||||
Get the schema of the system configuration
|
|
||||||
:return: Path
|
|
||||||
"""
|
|
||||||
return self._configuration_schema
|
|
||||||
|
|
||||||
@configuration_schema.setter
|
|
||||||
def configuration_schema(self, value):
|
|
||||||
"""
|
|
||||||
Set the schema of the system configuration
|
|
||||||
:param value: Path
|
|
||||||
"""
|
|
||||||
self._configuration_schema = value
|
|
@ -1,123 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic energy generation system (abstract class)
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from __future__ import annotations
|
|
||||||
from abc import ABC
|
|
||||||
from typing import Union, List
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_distribution_system import GenericDistributionSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_storage_system import GenericStorageSystem
|
|
||||||
|
|
||||||
|
|
||||||
class GenericGenerationSystem(ABC):
|
|
||||||
"""
|
|
||||||
GenericGenerationSystem class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
self._system_type = None
|
|
||||||
self._model_name = None
|
|
||||||
self._manufacturer = None
|
|
||||||
self._fuel_type = None
|
|
||||||
self._generic_distribution_systems = None
|
|
||||||
self._generic_storage_systems = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def system_type(self):
|
|
||||||
"""
|
|
||||||
Get type
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._system_type
|
|
||||||
|
|
||||||
@system_type.setter
|
|
||||||
def system_type(self, value):
|
|
||||||
"""
|
|
||||||
Set type
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._system_type = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def model_name(self):
|
|
||||||
"""
|
|
||||||
Get model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._model_name
|
|
||||||
|
|
||||||
@model_name.setter
|
|
||||||
def model_name(self, value):
|
|
||||||
"""
|
|
||||||
Set model name
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._model_name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def manufacturer(self):
|
|
||||||
"""
|
|
||||||
Get manufacturer's name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._manufacturer
|
|
||||||
|
|
||||||
@manufacturer.setter
|
|
||||||
def manufacturer(self, value):
|
|
||||||
"""
|
|
||||||
Set manufacturer's name
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._manufacturer = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def fuel_type(self):
|
|
||||||
"""
|
|
||||||
Get fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._fuel_type
|
|
||||||
|
|
||||||
@fuel_type.setter
|
|
||||||
def fuel_type(self, value):
|
|
||||||
"""
|
|
||||||
Set fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._fuel_type = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generic_distribution_systems(self) -> Union[None, List[GenericDistributionSystem]]:
|
|
||||||
"""
|
|
||||||
Get distributions systems connected to this generation system
|
|
||||||
:return: [GenericDistributionSystem]
|
|
||||||
"""
|
|
||||||
return self._generic_distribution_systems
|
|
||||||
|
|
||||||
@generic_distribution_systems.setter
|
|
||||||
def generic_distribution_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set distributions systems connected to this generation system
|
|
||||||
:param value: [GenericDistributionSystem]
|
|
||||||
"""
|
|
||||||
self._generic_distribution_systems = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def generic_storage_systems(self) -> Union[None, List[GenericStorageSystem]]:
|
|
||||||
"""
|
|
||||||
Get energy storage systems connected to this generation system
|
|
||||||
:return: [GenericStorageSystem]
|
|
||||||
"""
|
|
||||||
return self._generic_storage_systems
|
|
||||||
|
|
||||||
@generic_storage_systems.setter
|
|
||||||
def generic_storage_systems(self, value):
|
|
||||||
"""
|
|
||||||
Set energy storage systems connected to this generation system
|
|
||||||
:param value: [GenericStorageSystem]
|
|
||||||
"""
|
|
||||||
self._generic_storage_systems = value
|
|
@ -1,428 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic non PV energy generation system
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from typing import Union
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
|
|
||||||
from hub.city_model_structure.energy_systems.performance_curve import PerformanceCurves
|
|
||||||
|
|
||||||
|
|
||||||
class GenericNonPvGenerationSystem(GenericGenerationSystem):
|
|
||||||
"""
|
|
||||||
GenericNonPvGenerationSystem class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
super().__init__()
|
|
||||||
self._nominal_heat_output = None
|
|
||||||
self._maximum_heat_output = None
|
|
||||||
self._minimum_heat_output = None
|
|
||||||
self._heat_efficiency = None
|
|
||||||
self._nominal_cooling_output = None
|
|
||||||
self._maximum_cooling_output = None
|
|
||||||
self._minimum_cooling_output = None
|
|
||||||
self._cooling_efficiency = None
|
|
||||||
self._electricity_efficiency = None
|
|
||||||
self._nominal_electricity_output = None
|
|
||||||
self._source_medium = None
|
|
||||||
self._source_temperature = None
|
|
||||||
self._source_mass_flow = None
|
|
||||||
self._supply_medium = None
|
|
||||||
self._maximum_heat_supply_temperature = None
|
|
||||||
self._minimum_heat_supply_temperature = None
|
|
||||||
self._maximum_cooling_supply_temperature = None
|
|
||||||
self._minimum_cooling_supply_temperature = None
|
|
||||||
self._heat_output_curve = None
|
|
||||||
self._heat_fuel_consumption_curve = None
|
|
||||||
self._heat_efficiency_curve = None
|
|
||||||
self._cooling_output_curve = None
|
|
||||||
self._cooling_fuel_consumption_curve = None
|
|
||||||
self._cooling_efficiency_curve = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_heat_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_heat_output
|
|
||||||
|
|
||||||
@nominal_heat_output.setter
|
|
||||||
def nominal_heat_output(self, value):
|
|
||||||
"""
|
|
||||||
Set nominal heat output of heat generation devices in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_heat_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_heat_output(self):
|
|
||||||
"""
|
|
||||||
Get maximum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._maximum_heat_output
|
|
||||||
|
|
||||||
@maximum_heat_output.setter
|
|
||||||
def maximum_heat_output(self, value):
|
|
||||||
"""
|
|
||||||
Set maximum heat output of heat generation devices in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._maximum_heat_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_heat_output(self):
|
|
||||||
"""
|
|
||||||
Get minimum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._minimum_heat_output
|
|
||||||
|
|
||||||
@minimum_heat_output.setter
|
|
||||||
def minimum_heat_output(self, value):
|
|
||||||
"""
|
|
||||||
Set minimum heat output of heat generation devices in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._minimum_heat_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def source_medium(self):
|
|
||||||
"""
|
|
||||||
Get source_type from [air, water, ground, district_heating, grid, on_site_electricity]
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._source_medium
|
|
||||||
|
|
||||||
@source_medium.setter
|
|
||||||
def source_medium(self, value):
|
|
||||||
"""
|
|
||||||
Set source medium from [Air, Water, Geothermal, District Heating, Grid, Onsite Electricity]
|
|
||||||
:param value: [string]
|
|
||||||
"""
|
|
||||||
self._source_medium = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def supply_medium(self):
|
|
||||||
"""
|
|
||||||
Get the supply medium from ['air', 'water']
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._supply_medium
|
|
||||||
|
|
||||||
@supply_medium.setter
|
|
||||||
def supply_medium(self, value):
|
|
||||||
"""
|
|
||||||
Set the supply medium from ['air', 'water']
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._supply_medium = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get heat_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._heat_efficiency
|
|
||||||
|
|
||||||
@heat_efficiency.setter
|
|
||||||
def heat_efficiency(self, value):
|
|
||||||
"""
|
|
||||||
Set heat_efficiency
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._heat_efficiency = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_cooling_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal cooling output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_cooling_output
|
|
||||||
|
|
||||||
@nominal_cooling_output.setter
|
|
||||||
def nominal_cooling_output(self, value):
|
|
||||||
"""
|
|
||||||
Set nominal cooling output of heat generation devices in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_cooling_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_cooling_output(self):
|
|
||||||
"""
|
|
||||||
Get maximum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._maximum_cooling_output
|
|
||||||
|
|
||||||
@maximum_cooling_output.setter
|
|
||||||
def maximum_cooling_output(self, value):
|
|
||||||
"""
|
|
||||||
Set maximum heat output of heat generation devices in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._maximum_cooling_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_cooling_output(self):
|
|
||||||
"""
|
|
||||||
Get minimum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._minimum_cooling_output
|
|
||||||
|
|
||||||
@minimum_cooling_output.setter
|
|
||||||
def minimum_cooling_output(self, value):
|
|
||||||
"""
|
|
||||||
Set minimum heat output of heat generation devices in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._minimum_cooling_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get cooling_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._cooling_efficiency
|
|
||||||
|
|
||||||
@cooling_efficiency.setter
|
|
||||||
def cooling_efficiency(self, value):
|
|
||||||
"""
|
|
||||||
Set cooling_efficiency
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._cooling_efficiency = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def electricity_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get electricity_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._electricity_efficiency
|
|
||||||
|
|
||||||
@electricity_efficiency.setter
|
|
||||||
def electricity_efficiency(self, value):
|
|
||||||
"""
|
|
||||||
Set electricity_efficiency
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._electricity_efficiency = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def source_temperature(self):
|
|
||||||
"""
|
|
||||||
Get source_temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._source_temperature
|
|
||||||
|
|
||||||
@source_temperature.setter
|
|
||||||
def source_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set source_temperature in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._source_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def source_mass_flow(self):
|
|
||||||
"""
|
|
||||||
Get source_mass_flow in kg/s
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._source_mass_flow
|
|
||||||
|
|
||||||
@source_mass_flow.setter
|
|
||||||
def source_mass_flow(self, value):
|
|
||||||
"""
|
|
||||||
Set source_mass_flow in kg/s
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._source_mass_flow = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_electricity_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal_power_output of electricity generation devices or inverters in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_electricity_output
|
|
||||||
|
|
||||||
@nominal_electricity_output.setter
|
|
||||||
def nominal_electricity_output(self, value):
|
|
||||||
"""
|
|
||||||
Get nominal_power_output of electricity generation devices or inverters in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_electricity_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_heat_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the maximum heat supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._minimum_heat_supply_temperature
|
|
||||||
|
|
||||||
@maximum_heat_supply_temperature.setter
|
|
||||||
def maximum_heat_supply_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set maximum heating supply temperature in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._maximum_heat_supply_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_heat_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the minimum heat supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._minimum_heat_supply_temperature
|
|
||||||
|
|
||||||
@minimum_heat_supply_temperature.setter
|
|
||||||
def minimum_heat_supply_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set minimum heating supply temperature in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._minimum_heat_supply_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_cooling_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the maximum cooling supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._maximum_cooling_supply_temperature
|
|
||||||
|
|
||||||
@maximum_cooling_supply_temperature.setter
|
|
||||||
def maximum_cooling_supply_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set maximum cooling supply temperature in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._maximum_cooling_supply_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_cooling_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the minimum cooling supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._minimum_cooling_supply_temperature
|
|
||||||
|
|
||||||
@minimum_cooling_supply_temperature.setter
|
|
||||||
def minimum_cooling_supply_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set minimum cooling supply temperature in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._minimum_cooling_supply_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_output_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heat output curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._heat_output_curve
|
|
||||||
|
|
||||||
@heat_output_curve.setter
|
|
||||||
def heat_output_curve(self, value):
|
|
||||||
"""
|
|
||||||
Set the heat output curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
self._heat_output_curve = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating fuel consumption curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._heat_fuel_consumption_curve
|
|
||||||
|
|
||||||
@heat_fuel_consumption_curve.setter
|
|
||||||
def heat_fuel_consumption_curve(self, value):
|
|
||||||
"""
|
|
||||||
Set the heating fuel consumption curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
self._heat_fuel_consumption_curve = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_efficiency_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating efficiency curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._heat_efficiency_curve
|
|
||||||
|
|
||||||
@heat_efficiency_curve.setter
|
|
||||||
def heat_efficiency_curve(self, value):
|
|
||||||
"""
|
|
||||||
Set the heating efficiency curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
self._heat_efficiency_curve = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_output_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heat output curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._cooling_output_curve
|
|
||||||
|
|
||||||
@cooling_output_curve.setter
|
|
||||||
def cooling_output_curve(self, value):
|
|
||||||
"""
|
|
||||||
Set the cooling output curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
self._cooling_output_curve = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating fuel consumption curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._cooling_fuel_consumption_curve
|
|
||||||
|
|
||||||
@cooling_fuel_consumption_curve.setter
|
|
||||||
def cooling_fuel_consumption_curve(self, value):
|
|
||||||
"""
|
|
||||||
Set the heating fuel consumption curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
self._cooling_fuel_consumption_curve = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_efficiency_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating efficiency curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._cooling_efficiency_curve
|
|
||||||
|
|
||||||
@cooling_efficiency_curve.setter
|
|
||||||
def cooling_efficiency_curve(self, value):
|
|
||||||
"""
|
|
||||||
Set the heating efficiency curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
self._cooling_efficiency_curve = value
|
|
@ -1,187 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic PV energy generation system
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
|
|
||||||
|
|
||||||
|
|
||||||
class GenericPvGenerationSystem(GenericGenerationSystem):
|
|
||||||
"""
|
|
||||||
GenericPvGenerationSystem class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
super().__init__()
|
|
||||||
self._electricity_efficiency = None
|
|
||||||
self._nominal_electricity_output = None
|
|
||||||
self._nominal_ambient_temperature = None
|
|
||||||
self._nominal_cell_temperature = None
|
|
||||||
self._nominal_radiation = None
|
|
||||||
self._standard_test_condition_cell_temperature = None
|
|
||||||
self._standard_test_condition_maximum_power = None
|
|
||||||
self._cell_temperature_coefficient = None
|
|
||||||
self._width = None
|
|
||||||
self._height = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_electricity_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal_power_output of electricity generation devices or inverters in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_electricity_output
|
|
||||||
|
|
||||||
@nominal_electricity_output.setter
|
|
||||||
def nominal_electricity_output(self, value):
|
|
||||||
"""
|
|
||||||
Set nominal_power_output of electricity generation devices or inverters in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_electricity_output = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def electricity_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get electricity_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._electricity_efficiency
|
|
||||||
|
|
||||||
@electricity_efficiency.setter
|
|
||||||
def electricity_efficiency(self, value):
|
|
||||||
"""
|
|
||||||
Set electricity_efficiency
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._electricity_efficiency = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_ambient_temperature(self):
|
|
||||||
"""
|
|
||||||
Get nominal ambient temperature of PV panels in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_ambient_temperature
|
|
||||||
|
|
||||||
@nominal_ambient_temperature.setter
|
|
||||||
def nominal_ambient_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set nominal ambient temperature of PV panels in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_ambient_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_cell_temperature(self):
|
|
||||||
"""
|
|
||||||
Get nominal cell temperature of PV panels in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_cell_temperature
|
|
||||||
|
|
||||||
@nominal_cell_temperature.setter
|
|
||||||
def nominal_cell_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set nominal cell temperature of PV panels in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_cell_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_radiation(self):
|
|
||||||
"""
|
|
||||||
Get nominal radiation of PV panels
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_radiation
|
|
||||||
|
|
||||||
@nominal_radiation.setter
|
|
||||||
def nominal_radiation(self, value):
|
|
||||||
"""
|
|
||||||
Set nominal radiation of PV panels
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._nominal_radiation = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def standard_test_condition_cell_temperature(self):
|
|
||||||
"""
|
|
||||||
Get standard test condition cell temperature of PV panels in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._standard_test_condition_cell_temperature
|
|
||||||
|
|
||||||
@standard_test_condition_cell_temperature.setter
|
|
||||||
def standard_test_condition_cell_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set standard test condition cell temperature of PV panels in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._standard_test_condition_cell_temperature = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def standard_test_condition_maximum_power(self):
|
|
||||||
"""
|
|
||||||
Get standard test condition maximum power of PV panels in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._standard_test_condition_maximum_power
|
|
||||||
|
|
||||||
@standard_test_condition_maximum_power.setter
|
|
||||||
def standard_test_condition_maximum_power(self, value):
|
|
||||||
"""
|
|
||||||
Set standard test condition maximum power of PV panels in W
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._standard_test_condition_maximum_power = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cell_temperature_coefficient(self):
|
|
||||||
"""
|
|
||||||
Get cell temperature coefficient of PV module
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._cell_temperature_coefficient
|
|
||||||
|
|
||||||
@cell_temperature_coefficient.setter
|
|
||||||
def cell_temperature_coefficient(self, value):
|
|
||||||
"""
|
|
||||||
Set cell temperature coefficient of PV module
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._cell_temperature_coefficient = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def width(self):
|
|
||||||
"""
|
|
||||||
Get PV module width in m
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._width
|
|
||||||
|
|
||||||
@width.setter
|
|
||||||
def width(self, value):
|
|
||||||
"""
|
|
||||||
Set PV module width in m
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._width = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def height(self):
|
|
||||||
"""
|
|
||||||
Get PV module height in m
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._height
|
|
||||||
|
|
||||||
@height.setter
|
|
||||||
def height(self, value):
|
|
||||||
"""
|
|
||||||
Set PV module height in m
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._height = value
|
|
@ -1,118 +0,0 @@
|
|||||||
"""
|
|
||||||
Energy System catalog heat generation system
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|
||||||
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from abc import ABC
|
|
||||||
|
|
||||||
|
|
||||||
class GenericStorageSystem(ABC):
|
|
||||||
"""
|
|
||||||
Generic storage System class
|
|
||||||
"""
|
|
||||||
def __init__(self):
|
|
||||||
self._type_energy_stored = None
|
|
||||||
self._storage_type = None
|
|
||||||
self._model_name = None
|
|
||||||
self._manufacturer = None
|
|
||||||
self._nominal_capacity = None
|
|
||||||
self._losses_ratio = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def type_energy_stored(self):
|
|
||||||
"""
|
|
||||||
Get type of energy stored from ['electrical', 'thermal']
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._type_energy_stored
|
|
||||||
|
|
||||||
@type_energy_stored.setter
|
|
||||||
def type_energy_stored(self, value):
|
|
||||||
"""
|
|
||||||
Set type of energy stored from ['electrical', 'thermal']
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
self._type_energy_stored = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def storage_type(self):
|
|
||||||
"""
|
|
||||||
Get storage type
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._storage_type
|
|
||||||
|
|
||||||
@storage_type.setter
|
|
||||||
def storage_type(self, value):
|
|
||||||
"""
|
|
||||||
Get storage type
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._storage_type = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def model_name(self):
|
|
||||||
"""
|
|
||||||
Get system model
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._model_name
|
|
||||||
|
|
||||||
@model_name.setter
|
|
||||||
def model_name(self, value):
|
|
||||||
"""
|
|
||||||
Set system model
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._model_name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def manufacturer(self):
|
|
||||||
"""
|
|
||||||
Get name of manufacturer
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._manufacturer
|
|
||||||
|
|
||||||
@manufacturer.setter
|
|
||||||
def manufacturer(self, value):
|
|
||||||
"""
|
|
||||||
Set name of manufacturer
|
|
||||||
:param value: string
|
|
||||||
"""
|
|
||||||
self._manufacturer = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_capacity(self):
|
|
||||||
"""
|
|
||||||
Get the nominal capacity of storage systems in Jules
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._nominal_capacity
|
|
||||||
|
|
||||||
@nominal_capacity.setter
|
|
||||||
def nominal_capacity(self, value):
|
|
||||||
"""
|
|
||||||
Set the nominal capacity of storage systems in Jules
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
self._nominal_capacity = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def losses_ratio(self):
|
|
||||||
"""
|
|
||||||
Get the losses-ratio of storage system in Jules lost / Jules stored
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._losses_ratio
|
|
||||||
|
|
||||||
@losses_ratio.setter
|
|
||||||
def losses_ratio(self, value):
|
|
||||||
"""
|
|
||||||
Set the losses-ratio of storage system in Jules lost / Jules stored
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
self._losses_ratio = value
|
|
@ -1,88 +0,0 @@
|
|||||||
"""
|
|
||||||
Generic thermal storage system
|
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
|
||||||
Copyright © 2023 Concordia CERC group
|
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|
||||||
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|
||||||
"""
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_storage_system import GenericStorageSystem
|
|
||||||
from hub.city_model_structure.building_demand.layer import Layer
|
|
||||||
|
|
||||||
|
|
||||||
class GenericThermalStorageSystem(GenericStorageSystem):
|
|
||||||
""""
|
|
||||||
Generic Thermal Storage System Class
|
|
||||||
"""
|
|
||||||
|
|
||||||
def __init__(self):
|
|
||||||
|
|
||||||
super().__init__()
|
|
||||||
self._volume = None
|
|
||||||
self._height = None
|
|
||||||
self._layers = None
|
|
||||||
self._maximum_operating_temperature = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def volume(self):
|
|
||||||
"""
|
|
||||||
Get the physical volume of the storage system in cubic meters
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._volume
|
|
||||||
|
|
||||||
@volume.setter
|
|
||||||
def volume(self, value):
|
|
||||||
"""
|
|
||||||
Set the physical volume of the storage system in cubic meters
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._volume = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def height(self):
|
|
||||||
"""
|
|
||||||
Get the diameter of the storage system in meters
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._height
|
|
||||||
|
|
||||||
@height.setter
|
|
||||||
def height(self, value):
|
|
||||||
"""
|
|
||||||
Set the diameter of the storage system in meters
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._height = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def layers(self) -> [Layer]:
|
|
||||||
"""
|
|
||||||
Get construction layers
|
|
||||||
:return: [layer]
|
|
||||||
"""
|
|
||||||
return self._layers
|
|
||||||
|
|
||||||
@layers.setter
|
|
||||||
def layers(self, value):
|
|
||||||
"""
|
|
||||||
Set construction layers
|
|
||||||
:param value: [layer]
|
|
||||||
"""
|
|
||||||
self._layers = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_operating_temperature(self):
|
|
||||||
"""
|
|
||||||
Get maximum operating temperature of the storage system in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._maximum_operating_temperature
|
|
||||||
|
|
||||||
@maximum_operating_temperature.setter
|
|
||||||
def maximum_operating_temperature(self, value):
|
|
||||||
"""
|
|
||||||
Set maximum operating temperature of the storage system in degree Celsius
|
|
||||||
:param value: float
|
|
||||||
"""
|
|
||||||
self._maximum_operating_temperature = value
|
|
@ -1,27 +1,435 @@
|
|||||||
"""
|
"""
|
||||||
Non PV generation system definition
|
Non PV energy generation system
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
|
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from typing import Union
|
from typing import Union
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
|
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||||
from hub.city_model_structure.energy_systems.performance_curve import PerformanceCurves
|
from hub.city_model_structure.energy_systems.performance_curve import PerformanceCurves
|
||||||
|
|
||||||
|
|
||||||
class NonPvGenerationSystem(GenericGenerationSystem):
|
class NonPvGenerationSystem(GenerationSystem):
|
||||||
"""
|
"""
|
||||||
NonPvGenerationSystem class
|
NonPvGenerationSystem class
|
||||||
"""
|
"""
|
||||||
def __init__(self, non_pv_generation_system):
|
def __init__(self):
|
||||||
super().__init__()
|
super().__init__()
|
||||||
self._non_pv_generation_system = non_pv_generation_system
|
self._nominal_heat_output = None
|
||||||
|
self._maximum_heat_output = None
|
||||||
|
self._minimum_heat_output = None
|
||||||
|
self._heat_efficiency = None
|
||||||
|
self._nominal_cooling_output = None
|
||||||
|
self._maximum_cooling_output = None
|
||||||
|
self._minimum_cooling_output = None
|
||||||
|
self._cooling_efficiency = None
|
||||||
|
self._electricity_efficiency = None
|
||||||
|
self._nominal_electricity_output = None
|
||||||
|
self._source_medium = None
|
||||||
|
self._source_temperature = None
|
||||||
|
self._source_mass_flow = None
|
||||||
|
self._supply_medium = None
|
||||||
|
self._maximum_heat_supply_temperature = None
|
||||||
|
self._minimum_heat_supply_temperature = None
|
||||||
|
self._maximum_cooling_supply_temperature = None
|
||||||
|
self._minimum_cooling_supply_temperature = None
|
||||||
|
self._heat_output_curve = None
|
||||||
|
self._heat_fuel_consumption_curve = None
|
||||||
|
self._heat_efficiency_curve = None
|
||||||
|
self._cooling_output_curve = None
|
||||||
|
self._cooling_fuel_consumption_curve = None
|
||||||
|
self._cooling_efficiency_curve = None
|
||||||
self._heat_power = None
|
self._heat_power = None
|
||||||
self._cooling_power = None
|
self._cooling_power = None
|
||||||
self._electricity_power = None
|
self._electricity_power = None
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_heat_output(self):
|
||||||
|
"""
|
||||||
|
Get nominal heat output of heat generation devices in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_heat_output
|
||||||
|
|
||||||
|
@nominal_heat_output.setter
|
||||||
|
def nominal_heat_output(self, value):
|
||||||
|
"""
|
||||||
|
Set nominal heat output of heat generation devices in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_heat_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def maximum_heat_output(self):
|
||||||
|
"""
|
||||||
|
Get maximum heat output of heat generation devices in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._maximum_heat_output
|
||||||
|
|
||||||
|
@maximum_heat_output.setter
|
||||||
|
def maximum_heat_output(self, value):
|
||||||
|
"""
|
||||||
|
Set maximum heat output of heat generation devices in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._maximum_heat_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def minimum_heat_output(self):
|
||||||
|
"""
|
||||||
|
Get minimum heat output of heat generation devices in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._minimum_heat_output
|
||||||
|
|
||||||
|
@minimum_heat_output.setter
|
||||||
|
def minimum_heat_output(self, value):
|
||||||
|
"""
|
||||||
|
Set minimum heat output of heat generation devices in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._minimum_heat_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def source_medium(self):
|
||||||
|
"""
|
||||||
|
Get source_type from [air, water, ground, district_heating, grid, on_site_electricity]
|
||||||
|
:return: string
|
||||||
|
"""
|
||||||
|
return self._source_medium
|
||||||
|
|
||||||
|
@source_medium.setter
|
||||||
|
def source_medium(self, value):
|
||||||
|
"""
|
||||||
|
Set source medium from [Air, Water, Geothermal, District Heating, Grid, Onsite Electricity]
|
||||||
|
:param value: [string]
|
||||||
|
"""
|
||||||
|
self._source_medium = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def supply_medium(self):
|
||||||
|
"""
|
||||||
|
Get the supply medium from ['air', 'water']
|
||||||
|
:return: string
|
||||||
|
"""
|
||||||
|
return self._supply_medium
|
||||||
|
|
||||||
|
@supply_medium.setter
|
||||||
|
def supply_medium(self, value):
|
||||||
|
"""
|
||||||
|
Set the supply medium from ['air', 'water']
|
||||||
|
:param value: string
|
||||||
|
"""
|
||||||
|
self._supply_medium = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def heat_efficiency(self):
|
||||||
|
"""
|
||||||
|
Get heat_efficiency
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._heat_efficiency
|
||||||
|
|
||||||
|
@heat_efficiency.setter
|
||||||
|
def heat_efficiency(self, value):
|
||||||
|
"""
|
||||||
|
Set heat_efficiency
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._heat_efficiency = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_cooling_output(self):
|
||||||
|
"""
|
||||||
|
Get nominal cooling output of heat generation devices in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_cooling_output
|
||||||
|
|
||||||
|
@nominal_cooling_output.setter
|
||||||
|
def nominal_cooling_output(self, value):
|
||||||
|
"""
|
||||||
|
Set nominal cooling output of heat generation devices in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_cooling_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def maximum_cooling_output(self):
|
||||||
|
"""
|
||||||
|
Get maximum heat output of heat generation devices in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._maximum_cooling_output
|
||||||
|
|
||||||
|
@maximum_cooling_output.setter
|
||||||
|
def maximum_cooling_output(self, value):
|
||||||
|
"""
|
||||||
|
Set maximum heat output of heat generation devices in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._maximum_cooling_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def minimum_cooling_output(self):
|
||||||
|
"""
|
||||||
|
Get minimum heat output of heat generation devices in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._minimum_cooling_output
|
||||||
|
|
||||||
|
@minimum_cooling_output.setter
|
||||||
|
def minimum_cooling_output(self, value):
|
||||||
|
"""
|
||||||
|
Set minimum heat output of heat generation devices in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._minimum_cooling_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def cooling_efficiency(self):
|
||||||
|
"""
|
||||||
|
Get cooling_efficiency
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._cooling_efficiency
|
||||||
|
|
||||||
|
@cooling_efficiency.setter
|
||||||
|
def cooling_efficiency(self, value):
|
||||||
|
"""
|
||||||
|
Set cooling_efficiency
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._cooling_efficiency = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def electricity_efficiency(self):
|
||||||
|
"""
|
||||||
|
Get electricity_efficiency
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._electricity_efficiency
|
||||||
|
|
||||||
|
@electricity_efficiency.setter
|
||||||
|
def electricity_efficiency(self, value):
|
||||||
|
"""
|
||||||
|
Set electricity_efficiency
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._electricity_efficiency = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def source_temperature(self):
|
||||||
|
"""
|
||||||
|
Get source_temperature in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._source_temperature
|
||||||
|
|
||||||
|
@source_temperature.setter
|
||||||
|
def source_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set source_temperature in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._source_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def source_mass_flow(self):
|
||||||
|
"""
|
||||||
|
Get source_mass_flow in kg/s
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._source_mass_flow
|
||||||
|
|
||||||
|
@source_mass_flow.setter
|
||||||
|
def source_mass_flow(self, value):
|
||||||
|
"""
|
||||||
|
Set source_mass_flow in kg/s
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._source_mass_flow = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_electricity_output(self):
|
||||||
|
"""
|
||||||
|
Get nominal_power_output of electricity generation devices or inverters in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_electricity_output
|
||||||
|
|
||||||
|
@nominal_electricity_output.setter
|
||||||
|
def nominal_electricity_output(self, value):
|
||||||
|
"""
|
||||||
|
Get nominal_power_output of electricity generation devices or inverters in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_electricity_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def maximum_heat_supply_temperature(self):
|
||||||
|
"""
|
||||||
|
Get the maximum heat supply temperature in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._minimum_heat_supply_temperature
|
||||||
|
|
||||||
|
@maximum_heat_supply_temperature.setter
|
||||||
|
def maximum_heat_supply_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set maximum heating supply temperature in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._maximum_heat_supply_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def minimum_heat_supply_temperature(self):
|
||||||
|
"""
|
||||||
|
Get the minimum heat supply temperature in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._minimum_heat_supply_temperature
|
||||||
|
|
||||||
|
@minimum_heat_supply_temperature.setter
|
||||||
|
def minimum_heat_supply_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set minimum heating supply temperature in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._minimum_heat_supply_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def maximum_cooling_supply_temperature(self):
|
||||||
|
"""
|
||||||
|
Get the maximum cooling supply temperature in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._maximum_cooling_supply_temperature
|
||||||
|
|
||||||
|
@maximum_cooling_supply_temperature.setter
|
||||||
|
def maximum_cooling_supply_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set maximum cooling supply temperature in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._maximum_cooling_supply_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def minimum_cooling_supply_temperature(self):
|
||||||
|
"""
|
||||||
|
Get the minimum cooling supply temperature in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._minimum_cooling_supply_temperature
|
||||||
|
|
||||||
|
@minimum_cooling_supply_temperature.setter
|
||||||
|
def minimum_cooling_supply_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set minimum cooling supply temperature in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._minimum_cooling_supply_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def heat_output_curve(self) -> Union[None, PerformanceCurves]:
|
||||||
|
"""
|
||||||
|
Get the heat output curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
return self._heat_output_curve
|
||||||
|
|
||||||
|
@heat_output_curve.setter
|
||||||
|
def heat_output_curve(self, value):
|
||||||
|
"""
|
||||||
|
Set the heat output curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
self._heat_output_curve = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def heat_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
|
||||||
|
"""
|
||||||
|
Get the heating fuel consumption curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
return self._heat_fuel_consumption_curve
|
||||||
|
|
||||||
|
@heat_fuel_consumption_curve.setter
|
||||||
|
def heat_fuel_consumption_curve(self, value):
|
||||||
|
"""
|
||||||
|
Set the heating fuel consumption curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
self._heat_fuel_consumption_curve = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def heat_efficiency_curve(self) -> Union[None, PerformanceCurves]:
|
||||||
|
"""
|
||||||
|
Get the heating efficiency curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
return self._heat_efficiency_curve
|
||||||
|
|
||||||
|
@heat_efficiency_curve.setter
|
||||||
|
def heat_efficiency_curve(self, value):
|
||||||
|
"""
|
||||||
|
Set the heating efficiency curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
self._heat_efficiency_curve = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def cooling_output_curve(self) -> Union[None, PerformanceCurves]:
|
||||||
|
"""
|
||||||
|
Get the heat output curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
return self._cooling_output_curve
|
||||||
|
|
||||||
|
@cooling_output_curve.setter
|
||||||
|
def cooling_output_curve(self, value):
|
||||||
|
"""
|
||||||
|
Set the cooling output curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
self._cooling_output_curve = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def cooling_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
|
||||||
|
"""
|
||||||
|
Get the heating fuel consumption curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
return self._cooling_fuel_consumption_curve
|
||||||
|
|
||||||
|
@cooling_fuel_consumption_curve.setter
|
||||||
|
def cooling_fuel_consumption_curve(self, value):
|
||||||
|
"""
|
||||||
|
Set the heating fuel consumption curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
self._cooling_fuel_consumption_curve = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def cooling_efficiency_curve(self) -> Union[None, PerformanceCurves]:
|
||||||
|
"""
|
||||||
|
Get the heating efficiency curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
return self._cooling_efficiency_curve
|
||||||
|
|
||||||
|
@cooling_efficiency_curve.setter
|
||||||
|
def cooling_efficiency_curve(self, value):
|
||||||
|
"""
|
||||||
|
Set the heating efficiency curve of the heat generation device
|
||||||
|
:return: PerformanceCurve
|
||||||
|
"""
|
||||||
|
self._cooling_efficiency_curve = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def heat_power(self):
|
def heat_power(self):
|
||||||
"""
|
"""
|
||||||
@ -70,194 +478,3 @@ class NonPvGenerationSystem(GenericGenerationSystem):
|
|||||||
"""
|
"""
|
||||||
self._electricity_power = value
|
self._electricity_power = value
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_heat_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.nominal_heat_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_heat_output(self):
|
|
||||||
"""
|
|
||||||
Get maximum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.maximum_heat_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_heat_output(self):
|
|
||||||
"""
|
|
||||||
Get minimum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.minimum_heat_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def source_medium(self):
|
|
||||||
"""
|
|
||||||
Get source_type from [air, water, ground, district_heating, grid, on_site_electricity]
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.source_medium
|
|
||||||
|
|
||||||
@property
|
|
||||||
def supply_medium(self):
|
|
||||||
"""
|
|
||||||
Get the supply medium from ['air', 'water']
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.supply_medium
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get heat_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.heat_efficiency
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_cooling_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal cooling output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.nominal_cooling_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_cooling_output(self):
|
|
||||||
"""
|
|
||||||
Get maximum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.maximum_cooling_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_cooling_output(self):
|
|
||||||
"""
|
|
||||||
Get minimum heat output of heat generation devices in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.minimum_cooling_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get cooling_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.cooling_efficiency
|
|
||||||
|
|
||||||
@property
|
|
||||||
def electricity_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get electricity_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.electricity_efficiency
|
|
||||||
|
|
||||||
@property
|
|
||||||
def source_temperature(self):
|
|
||||||
"""
|
|
||||||
Get source_temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.source_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def source_mass_flow(self):
|
|
||||||
"""
|
|
||||||
Get source_mass_flow in kg/s
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.source_mass_flow
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_electricity_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal_power_output of electricity generation devices or inverters in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.nominal_electricity_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_heat_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the maximum heat supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.maximum_heat_supply_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_heat_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the minimum heat supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.minimum_heat_supply_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def maximum_cooling_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the maximum cooling supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.maximum_cooling_supply_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def minimum_cooling_supply_temperature(self):
|
|
||||||
"""
|
|
||||||
Get the minimum cooling supply temperature in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.minimum_cooling_supply_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_output_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heat output curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.heat_output_curve
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating fuel consumption curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.heat_fuel_consumption_curve
|
|
||||||
|
|
||||||
@property
|
|
||||||
def heat_efficiency_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating efficiency curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.heat_efficiency_curve
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_output_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heat output curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.cooling_output_curve
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating fuel consumption curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.cooling_fuel_consumption_curve
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cooling_efficiency_curve(self) -> Union[None, PerformanceCurves]:
|
|
||||||
"""
|
|
||||||
Get the heating efficiency curve of the heat generation device
|
|
||||||
:return: PerformanceCurve
|
|
||||||
"""
|
|
||||||
return self._non_pv_generation_system.cooling_efficiency_curve
|
|
||||||
|
@ -1,22 +1,192 @@
|
|||||||
"""
|
"""
|
||||||
PV generation system definition
|
PV energy generation system
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
|
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
|
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||||
|
|
||||||
|
|
||||||
class PvGenerationSystem(GenericGenerationSystem):
|
class PvGenerationSystem(GenerationSystem):
|
||||||
"""
|
"""
|
||||||
PvGenerationSystem class
|
PvGenerationSystem class
|
||||||
"""
|
"""
|
||||||
def __init__(self, generic_pv_generation_system):
|
def __init__(self):
|
||||||
super().__init__()
|
super().__init__()
|
||||||
self._generic_pv_generation_system = generic_pv_generation_system
|
self._electricity_efficiency = None
|
||||||
|
self._nominal_electricity_output = None
|
||||||
|
self._nominal_ambient_temperature = None
|
||||||
|
self._nominal_cell_temperature = None
|
||||||
|
self._nominal_radiation = None
|
||||||
|
self._standard_test_condition_cell_temperature = None
|
||||||
|
self._standard_test_condition_maximum_power = None
|
||||||
|
self._cell_temperature_coefficient = None
|
||||||
|
self._width = None
|
||||||
|
self._height = None
|
||||||
self._electricity_power = None
|
self._electricity_power = None
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_electricity_output(self):
|
||||||
|
"""
|
||||||
|
Get nominal_power_output of electricity generation devices or inverters in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_electricity_output
|
||||||
|
|
||||||
|
@nominal_electricity_output.setter
|
||||||
|
def nominal_electricity_output(self, value):
|
||||||
|
"""
|
||||||
|
Set nominal_power_output of electricity generation devices or inverters in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_electricity_output = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def electricity_efficiency(self):
|
||||||
|
"""
|
||||||
|
Get electricity_efficiency
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._electricity_efficiency
|
||||||
|
|
||||||
|
@electricity_efficiency.setter
|
||||||
|
def electricity_efficiency(self, value):
|
||||||
|
"""
|
||||||
|
Set electricity_efficiency
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._electricity_efficiency = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_ambient_temperature(self):
|
||||||
|
"""
|
||||||
|
Get nominal ambient temperature of PV panels in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_ambient_temperature
|
||||||
|
|
||||||
|
@nominal_ambient_temperature.setter
|
||||||
|
def nominal_ambient_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set nominal ambient temperature of PV panels in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_ambient_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_cell_temperature(self):
|
||||||
|
"""
|
||||||
|
Get nominal cell temperature of PV panels in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_cell_temperature
|
||||||
|
|
||||||
|
@nominal_cell_temperature.setter
|
||||||
|
def nominal_cell_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set nominal cell temperature of PV panels in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_cell_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def nominal_radiation(self):
|
||||||
|
"""
|
||||||
|
Get nominal radiation of PV panels
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._nominal_radiation
|
||||||
|
|
||||||
|
@nominal_radiation.setter
|
||||||
|
def nominal_radiation(self, value):
|
||||||
|
"""
|
||||||
|
Set nominal radiation of PV panels
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._nominal_radiation = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def standard_test_condition_cell_temperature(self):
|
||||||
|
"""
|
||||||
|
Get standard test condition cell temperature of PV panels in degree Celsius
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._standard_test_condition_cell_temperature
|
||||||
|
|
||||||
|
@standard_test_condition_cell_temperature.setter
|
||||||
|
def standard_test_condition_cell_temperature(self, value):
|
||||||
|
"""
|
||||||
|
Set standard test condition cell temperature of PV panels in degree Celsius
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._standard_test_condition_cell_temperature = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def standard_test_condition_maximum_power(self):
|
||||||
|
"""
|
||||||
|
Get standard test condition maximum power of PV panels in W
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._standard_test_condition_maximum_power
|
||||||
|
|
||||||
|
@standard_test_condition_maximum_power.setter
|
||||||
|
def standard_test_condition_maximum_power(self, value):
|
||||||
|
"""
|
||||||
|
Set standard test condition maximum power of PV panels in W
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._standard_test_condition_maximum_power = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def cell_temperature_coefficient(self):
|
||||||
|
"""
|
||||||
|
Get cell temperature coefficient of PV module
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._cell_temperature_coefficient
|
||||||
|
|
||||||
|
@cell_temperature_coefficient.setter
|
||||||
|
def cell_temperature_coefficient(self, value):
|
||||||
|
"""
|
||||||
|
Set cell temperature coefficient of PV module
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._cell_temperature_coefficient = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def width(self):
|
||||||
|
"""
|
||||||
|
Get PV module width in m
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._width
|
||||||
|
|
||||||
|
@width.setter
|
||||||
|
def width(self, value):
|
||||||
|
"""
|
||||||
|
Set PV module width in m
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._width = value
|
||||||
|
|
||||||
|
@property
|
||||||
|
def height(self):
|
||||||
|
"""
|
||||||
|
Get PV module height in m
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._height
|
||||||
|
|
||||||
|
@height.setter
|
||||||
|
def height(self, value):
|
||||||
|
"""
|
||||||
|
Set PV module height in m
|
||||||
|
:param value: float
|
||||||
|
"""
|
||||||
|
self._height = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def electricity_power(self):
|
def electricity_power(self):
|
||||||
"""
|
"""
|
||||||
@ -32,83 +202,3 @@ class PvGenerationSystem(GenericGenerationSystem):
|
|||||||
:param value: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._electricity_power = value
|
self._electricity_power = value
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_electricity_output(self):
|
|
||||||
"""
|
|
||||||
Get nominal_power_output of electricity generation devices or inverters in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.nominal_electricity_output
|
|
||||||
|
|
||||||
@property
|
|
||||||
def electricity_efficiency(self):
|
|
||||||
"""
|
|
||||||
Get electricity_efficiency
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.electricity_efficiency
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_ambient_temperature(self):
|
|
||||||
"""
|
|
||||||
Get nominal ambient temperature of PV panels in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.nominal_ambient_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_cell_temperature(self):
|
|
||||||
"""
|
|
||||||
Get nominal cell temperature of PV panels in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.nominal_cell_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def nominal_radiation(self):
|
|
||||||
"""
|
|
||||||
Get nominal radiation of PV panels
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.nominal_radiation
|
|
||||||
|
|
||||||
@property
|
|
||||||
def standard_test_condition_cell_temperature(self):
|
|
||||||
"""
|
|
||||||
Get standard test condition cell temperature of PV panels in degree Celsius
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.standard_test_condition_cell_temperature
|
|
||||||
|
|
||||||
@property
|
|
||||||
def standard_test_condition_maximum_power(self):
|
|
||||||
"""
|
|
||||||
Get standard test condition maximum power of PV panels in W
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.standard_test_condition_maximum_power
|
|
||||||
|
|
||||||
@property
|
|
||||||
def cell_temperature_coefficient(self):
|
|
||||||
"""
|
|
||||||
Get cell temperature coefficient of PV module
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.cell_temperature_coefficient
|
|
||||||
|
|
||||||
@property
|
|
||||||
def width(self):
|
|
||||||
"""
|
|
||||||
Get PV module width in m
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.width
|
|
||||||
|
|
||||||
@property
|
|
||||||
def height(self):
|
|
||||||
"""
|
|
||||||
Get PV module height in m
|
|
||||||
:return: float
|
|
||||||
"""
|
|
||||||
return self._generic_pv_generation_system.height
|
|
||||||
|
@ -1,61 +1,32 @@
|
|||||||
"""
|
"""
|
||||||
Energy System catalog heat generation system
|
Thermal storage system
|
||||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||||
Copyright © 2023 Concordia CERC group
|
Copyright © 2023 Concordia CERC group
|
||||||
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
|
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||||
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
|
||||||
"""
|
"""
|
||||||
|
|
||||||
|
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
|
||||||
from hub.city_model_structure.building_demand.layer import Layer
|
from hub.city_model_structure.building_demand.layer import Layer
|
||||||
|
|
||||||
|
|
||||||
class ThermalStorageSystem:
|
class ThermalStorageSystem(EnergyStorageSystem):
|
||||||
def __init__(self, generic_thermal_storage_system):
|
""""
|
||||||
self._generic_thermal_storage_system = generic_thermal_storage_system
|
Thermal Storage System Class
|
||||||
self._model_name = None
|
"""
|
||||||
self._manufacturer = None
|
|
||||||
|
def __init__(self):
|
||||||
|
|
||||||
|
super().__init__()
|
||||||
self._volume = None
|
self._volume = None
|
||||||
self._height = None
|
self._height = None
|
||||||
self._layers = None
|
self._layers = None
|
||||||
self._maximum_operating_temperature = None
|
self._maximum_operating_temperature = None
|
||||||
self._generic_storage_system = None
|
|
||||||
|
|
||||||
@property
|
|
||||||
def model_name(self):
|
|
||||||
"""
|
|
||||||
Get the model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._model_name
|
|
||||||
|
|
||||||
@model_name.setter
|
|
||||||
def model_name(self, value):
|
|
||||||
"""
|
|
||||||
Set the model name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
self._model_name = value
|
|
||||||
|
|
||||||
@property
|
|
||||||
def manufacturer(self):
|
|
||||||
"""
|
|
||||||
Get the manufacturer name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
return self._manufacturer
|
|
||||||
|
|
||||||
@manufacturer.setter
|
|
||||||
def manufacturer(self, value):
|
|
||||||
"""
|
|
||||||
Set the manufacturer name
|
|
||||||
:return: string
|
|
||||||
"""
|
|
||||||
self._manufacturer = value
|
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def volume(self):
|
def volume(self):
|
||||||
"""
|
"""
|
||||||
Get the volume of thermal storage in m3
|
Get the physical volume of the storage system in cubic meters
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._volume
|
return self._volume
|
||||||
@ -63,15 +34,15 @@ class ThermalStorageSystem:
|
|||||||
@volume.setter
|
@volume.setter
|
||||||
def volume(self, value):
|
def volume(self, value):
|
||||||
"""
|
"""
|
||||||
Set the thermal storage volume in m3
|
Set the physical volume of the storage system in cubic meters
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._volume = value
|
self._volume = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def height(self):
|
def height(self):
|
||||||
"""
|
"""
|
||||||
Get the storage height in m
|
Get the diameter of the storage system in meters
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._height
|
return self._height
|
||||||
@ -79,31 +50,31 @@ class ThermalStorageSystem:
|
|||||||
@height.setter
|
@height.setter
|
||||||
def height(self, value):
|
def height(self, value):
|
||||||
"""
|
"""
|
||||||
Set the storage height in m
|
Set the diameter of the storage system in meters
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._height = value
|
self._height = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def generic_storage_system(self) -> GenericStorageSystem:
|
def layers(self) -> [Layer]:
|
||||||
"""
|
"""
|
||||||
Get associated generic_storage_system
|
Get construction layers
|
||||||
:return: GenericStorageSystem
|
:return: [layer]
|
||||||
"""
|
"""
|
||||||
return self._generic_storage_system
|
return self._layers
|
||||||
|
|
||||||
@generic_storage_system.setter
|
@layers.setter
|
||||||
def generic_storage_system(self, value):
|
def layers(self, value):
|
||||||
"""
|
"""
|
||||||
Set associated generic_storage_system
|
Set construction layers
|
||||||
:param value: GenericStorageSystem
|
:param value: [layer]
|
||||||
"""
|
"""
|
||||||
self._generic_storage_system = value
|
self._layers = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def maximum_operating_temperature(self):
|
def maximum_operating_temperature(self):
|
||||||
"""
|
"""
|
||||||
Get the storage maximum operating temperature in degree Celsius
|
Get maximum operating temperature of the storage system in degree Celsius
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._maximum_operating_temperature
|
return self._maximum_operating_temperature
|
||||||
@ -111,23 +82,7 @@ class ThermalStorageSystem:
|
|||||||
@maximum_operating_temperature.setter
|
@maximum_operating_temperature.setter
|
||||||
def maximum_operating_temperature(self, value):
|
def maximum_operating_temperature(self, value):
|
||||||
"""
|
"""
|
||||||
Set the storage maximum operating temperature in degree Celsius
|
Set maximum operating temperature of the storage system in degree Celsius
|
||||||
:return: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._maximum_operating_temperature = value
|
self._maximum_operating_temperature = value
|
||||||
|
|
||||||
@property
|
|
||||||
def layers(self) -> [Layer]:
|
|
||||||
"""
|
|
||||||
Get the storage system layers
|
|
||||||
:return: Layer
|
|
||||||
"""
|
|
||||||
return self._layers
|
|
||||||
|
|
||||||
@layers.setter
|
|
||||||
def layers(self, value):
|
|
||||||
"""
|
|
||||||
Set the storage system layers
|
|
||||||
:return: Layer
|
|
||||||
"""
|
|
||||||
self._layers = value
|
|
||||||
|
@ -8,20 +8,13 @@ Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
|||||||
import logging
|
import logging
|
||||||
import copy
|
import copy
|
||||||
|
|
||||||
from pandas import DataFrame
|
|
||||||
|
|
||||||
from hub.catalog_factories.energy_systems_catalog_factory import EnergySystemsCatalogFactory
|
from hub.catalog_factories.energy_systems_catalog_factory import EnergySystemsCatalogFactory
|
||||||
from hub.city_model_structure.energy_systems.generic_energy_system import GenericEnergySystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_distribution_system import GenericDistributionSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_non_pv_generation_system import GenericNonPvGenerationSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_pv_generation_system import GenericPvGenerationSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_electrical_storage_system import GenericElectricalStorageSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_thermal_storage_system import GenericThermalStorageSystem
|
|
||||||
from hub.city_model_structure.energy_systems.generic_emission_system import GenericEmissionSystem
|
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
||||||
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
|
||||||
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
||||||
|
from hub.city_model_structure.energy_systems.non_pv_generation_system import NonPvGenerationSystem
|
||||||
|
from hub.city_model_structure.energy_systems.pv_generation_system import PvGenerationSystem
|
||||||
|
from hub.city_model_structure.energy_systems.electrical_storage_system import ElectricalStorageSystem
|
||||||
|
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
||||||
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
||||||
from hub.helpers.dictionaries import Dictionaries
|
from hub.helpers.dictionaries import Dictionaries
|
||||||
|
|
||||||
@ -41,10 +34,6 @@ class MontrealCustomEnergySystemParameters:
|
|||||||
"""
|
"""
|
||||||
city = self._city
|
city = self._city
|
||||||
montreal_custom_catalog = EnergySystemsCatalogFactory('montreal_custom').catalog
|
montreal_custom_catalog = EnergySystemsCatalogFactory('montreal_custom').catalog
|
||||||
if city.energy_systems_connection_table is None:
|
|
||||||
_energy_systems_connection_table = DataFrame(columns=['Energy System Type', 'Building'])
|
|
||||||
else:
|
|
||||||
_energy_systems_connection_table = city.energy_systems_connection_table
|
|
||||||
if city.generic_energy_systems is None:
|
if city.generic_energy_systems is None:
|
||||||
_generic_energy_systems = {}
|
_generic_energy_systems = {}
|
||||||
else:
|
else:
|
||||||
@ -58,16 +47,12 @@ class MontrealCustomEnergySystemParameters:
|
|||||||
archetype_name)
|
archetype_name)
|
||||||
continue
|
continue
|
||||||
|
|
||||||
_energy_systems_connection_table, _generic_energy_systems = self._create_generic_systems(
|
if archetype.name not in _generic_energy_systems:
|
||||||
archetype,
|
_generic_energy_systems = self._create_generic_systems_list(archetype, _generic_energy_systems)
|
||||||
building,
|
|
||||||
_energy_systems_connection_table,
|
|
||||||
_generic_energy_systems
|
|
||||||
)
|
|
||||||
city.energy_systems_connection_table = _energy_systems_connection_table
|
|
||||||
city.generic_energy_systems = _generic_energy_systems
|
city.generic_energy_systems = _generic_energy_systems
|
||||||
|
|
||||||
self._associate_energy_systems(city)
|
self._assign_energy_systems_to_buildings(city)
|
||||||
|
|
||||||
@staticmethod
|
@staticmethod
|
||||||
def _search_archetypes(catalog, name):
|
def _search_archetypes(catalog, name):
|
||||||
@ -77,108 +62,88 @@ class MontrealCustomEnergySystemParameters:
|
|||||||
return building_archetype
|
return building_archetype
|
||||||
raise KeyError('archetype not found')
|
raise KeyError('archetype not found')
|
||||||
|
|
||||||
@staticmethod
|
def _create_generic_systems_list(self, archetype, _generic_energy_systems):
|
||||||
def _create_generic_systems(archetype, building,
|
|
||||||
_energy_systems_connection_table, _generic_energy_systems):
|
|
||||||
data = [archetype.name, building.name]
|
|
||||||
_energy_systems_connection_table.loc[len(_energy_systems_connection_table)] = data
|
|
||||||
if archetype.name not in _generic_energy_systems:
|
|
||||||
building_systems = []
|
building_systems = []
|
||||||
for system in archetype.systems:
|
for archetype_system in archetype.systems:
|
||||||
energy_system = GenericEnergySystem()
|
energy_system = EnergySystem()
|
||||||
_hub_demand_types = []
|
_hub_demand_types = []
|
||||||
for demand_type in system.demand_types:
|
for demand_type in archetype_system.demand_types:
|
||||||
_hub_demand_types.append(Dictionaries().montreal_demand_type_to_hub_energy_demand_type[demand_type])
|
_hub_demand_types.append(Dictionaries().montreal_demand_type_to_hub_energy_demand_type[demand_type])
|
||||||
energy_system.name = system.name
|
energy_system.name = archetype_system.name
|
||||||
energy_system.demand_types = _hub_demand_types
|
energy_system.demand_types = _hub_demand_types
|
||||||
|
energy_system.generation_systems = self._create_generation_systems(archetype_system)
|
||||||
_generation_systems = []
|
energy_system.distribution_systems = self._create_distribution_systems(archetype_system)
|
||||||
for catalog_generation_system in system.generation_systems:
|
|
||||||
if catalog_generation_system.system_type == 'PV system':
|
|
||||||
_generation_system = GenericPvGenerationSystem()
|
|
||||||
_type = 'PV system'
|
|
||||||
_generation_system.type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
|
||||||
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[catalog_generation_system.fuel_type]
|
|
||||||
_generation_system.fuel_type = _fuel_type
|
|
||||||
_generation_system.electricity_efficiency = catalog_generation_system.electricity_efficiency
|
|
||||||
_generic_storage_system = None
|
|
||||||
if catalog_generation_system.energy_storage_systems is not None:
|
|
||||||
_generic_storage_system = GenericElectricalStorageSystem()
|
|
||||||
_generic_storage_system.type_energy_stored = 'electrical'
|
|
||||||
_generation_system.generic_storage_systems = [_generic_storage_system]
|
|
||||||
else:
|
|
||||||
_generation_system = GenericNonPvGenerationSystem()
|
|
||||||
_type = catalog_generation_system.system_type
|
|
||||||
_generation_system.type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
|
||||||
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[catalog_generation_system.fuel_type]
|
|
||||||
_generation_system.fuel_type = _fuel_type
|
|
||||||
_generation_system.source_types = catalog_generation_system.source_medium
|
|
||||||
_generation_system.heat_efficiency = catalog_generation_system.heat_efficiency
|
|
||||||
_generation_system.cooling_efficiency = catalog_generation_system.cooling_efficiency
|
|
||||||
_generation_system.electricity_efficiency = catalog_generation_system.electricity_efficiency
|
|
||||||
_generic_storage_system = None
|
|
||||||
if catalog_generation_system.energy_storage_systems is not None:
|
|
||||||
if catalog_generation_system.energy_storage_systems.type_energy_stored == 'electrical':
|
|
||||||
_generic_storage_system = GenericElectricalStorageSystem()
|
|
||||||
_generic_storage_system.type_energy_stored = 'electrical'
|
|
||||||
else:
|
|
||||||
_generic_storage_system = GenericThermalStorageSystem()
|
|
||||||
_generic_storage_system.type_energy_stored = 'thermal'
|
|
||||||
_generation_system.generic_storage_systems = [_generic_storage_system]
|
|
||||||
_generation_systems.append(_generation_system)
|
|
||||||
energy_system.generation_systems = _generation_systems
|
|
||||||
|
|
||||||
_distribution_systems = []
|
|
||||||
for catalog_distribution_system in system.distribution_systems:
|
|
||||||
_distribution_system = GenericDistributionSystem()
|
|
||||||
_distribution_system.type = catalog_distribution_system.type
|
|
||||||
_distribution_system.distribution_consumption_fix_flow = \
|
|
||||||
catalog_distribution_system.distribution_consumption_fix_flow
|
|
||||||
_distribution_system.distribution_consumption_variable_flow = \
|
|
||||||
catalog_distribution_system.distribution_consumption_variable_flow
|
|
||||||
_distribution_system.heat_losses = catalog_distribution_system.heat_losses
|
|
||||||
_emission_system = None
|
|
||||||
if catalog_distribution_system.emission_systems is not None:
|
|
||||||
_emission_system = GenericEmissionSystem()
|
|
||||||
_distribution_system.generic_emission_systems = [_emission_system]
|
|
||||||
_distribution_systems.append(_distribution_system)
|
|
||||||
energy_system.distribution_systems = _distribution_systems
|
|
||||||
|
|
||||||
building_systems.append(energy_system)
|
building_systems.append(energy_system)
|
||||||
|
|
||||||
_generic_energy_systems[archetype.name] = building_systems
|
_generic_energy_systems[archetype.name] = building_systems
|
||||||
|
|
||||||
return _energy_systems_connection_table, _generic_energy_systems
|
return _generic_energy_systems
|
||||||
|
|
||||||
@staticmethod
|
@staticmethod
|
||||||
def _associate_energy_systems(city):
|
def _create_generation_systems(archetype_system):
|
||||||
energy_systems_connection = city.energy_systems_connection_table
|
_generation_systems = []
|
||||||
|
for archetype_generation_system in archetype_system.generation_systems:
|
||||||
|
if archetype_generation_system.system_type == 'PV system':
|
||||||
|
_generation_system = PvGenerationSystem()
|
||||||
|
_type = 'PV system'
|
||||||
|
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
||||||
|
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
||||||
|
_generation_system.fuel_type = _fuel_type
|
||||||
|
_generation_system.electricity_efficiency = archetype_generation_system.electricity_efficiency
|
||||||
|
_generic_storage_system = None
|
||||||
|
if archetype_generation_system.energy_storage_systems is not None:
|
||||||
|
_generic_storage_system = ElectricalStorageSystem()
|
||||||
|
_generic_storage_system.type_energy_stored = 'electrical'
|
||||||
|
_generation_system.energy_storage_systems = [_generic_storage_system]
|
||||||
|
else:
|
||||||
|
_generation_system = NonPvGenerationSystem()
|
||||||
|
_type = archetype_generation_system.system_type
|
||||||
|
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
||||||
|
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
||||||
|
_generation_system.fuel_type = _fuel_type
|
||||||
|
_generation_system.source_types = archetype_generation_system.source_medium
|
||||||
|
_generation_system.heat_efficiency = archetype_generation_system.heat_efficiency
|
||||||
|
_generation_system.cooling_efficiency = archetype_generation_system.cooling_efficiency
|
||||||
|
_generation_system.electricity_efficiency = archetype_generation_system.electricity_efficiency
|
||||||
|
_generic_storage_system = None
|
||||||
|
if archetype_generation_system.energy_storage_systems is not None:
|
||||||
|
if archetype_generation_system.energy_storage_systems.type_energy_stored == 'electrical':
|
||||||
|
_generic_storage_system = ElectricalStorageSystem()
|
||||||
|
_generic_storage_system.type_energy_stored = 'electrical'
|
||||||
|
else:
|
||||||
|
_generic_storage_system = ThermalStorageSystem()
|
||||||
|
_generic_storage_system.type_energy_stored = 'thermal'
|
||||||
|
_generation_system.energy_storage_systems = [_generic_storage_system]
|
||||||
|
_generation_systems.append(_generation_system)
|
||||||
|
return _generation_systems
|
||||||
|
|
||||||
|
@staticmethod
|
||||||
|
def _create_distribution_systems(archetype_system):
|
||||||
|
_distribution_systems = []
|
||||||
|
for archetype_distribution_system in archetype_system.distribution_systems:
|
||||||
|
_distribution_system = DistributionSystem()
|
||||||
|
_distribution_system.type = archetype_distribution_system.type
|
||||||
|
_distribution_system.distribution_consumption_fix_flow = \
|
||||||
|
archetype_distribution_system.distribution_consumption_fix_flow
|
||||||
|
_distribution_system.distribution_consumption_variable_flow = \
|
||||||
|
archetype_distribution_system.distribution_consumption_variable_flow
|
||||||
|
_distribution_system.heat_losses = archetype_distribution_system.heat_losses
|
||||||
|
_emission_system = None
|
||||||
|
if archetype_distribution_system.emission_systems is not None:
|
||||||
|
_emission_system = EmissionSystem()
|
||||||
|
_distribution_system.emission_systems = [_emission_system]
|
||||||
|
_distribution_systems.append(_distribution_system)
|
||||||
|
return _distribution_systems
|
||||||
|
|
||||||
|
@staticmethod
|
||||||
|
def _assign_energy_systems_to_buildings(city):
|
||||||
for building in city.buildings:
|
for building in city.buildings:
|
||||||
_building_energy_systems = []
|
_building_energy_systems = []
|
||||||
energy_systems = energy_systems_connection['Energy System Type'][
|
energy_systems_cluster_name = building.energy_systems_archetype_name
|
||||||
energy_systems_connection['Building'] == building.name]
|
if str(energy_systems_cluster_name) == 'nan':
|
||||||
for energy_system in energy_systems:
|
|
||||||
if str(energy_system) == 'nan':
|
|
||||||
break
|
break
|
||||||
_generic_building_energy_systems = city.generic_energy_systems[energy_system]
|
_generic_building_energy_systems = city.generic_energy_systems[energy_systems_cluster_name]
|
||||||
for _generic_building_energy_system in _generic_building_energy_systems:
|
for _generic_building_energy_system in _generic_building_energy_systems:
|
||||||
_building_energy_equipment = EnergySystem()
|
_building_energy_systems.append(copy.deepcopy(_generic_building_energy_system))
|
||||||
_building_energy_equipment.name = _generic_building_energy_system.name
|
|
||||||
_building_energy_equipment.demand_types = _generic_building_energy_system.demand_types
|
|
||||||
|
|
||||||
_building_distribution_system = DistributionSystem()
|
|
||||||
_building_distribution_system.generic_distribution_system = \
|
|
||||||
copy.deepcopy(_generic_building_energy_system.distribution_systems)
|
|
||||||
_building_emission_system = EmissionSystem()
|
|
||||||
_building_emission_system.generic_emission_system = \
|
|
||||||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
|
||||||
_building_generation_system = GenerationSystem()
|
|
||||||
_building_generation_system.generic_generation_system = \
|
|
||||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
|
||||||
|
|
||||||
_building_energy_equipment.generation_systems = _building_generation_system
|
|
||||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
|
||||||
_building_energy_equipment.emission_systems = _building_emission_system
|
|
||||||
|
|
||||||
_building_energy_systems.append(_building_energy_equipment)
|
|
||||||
building.energy_systems = _building_energy_systems
|
building.energy_systems = _building_energy_systems
|
||||||
|
@ -16,8 +16,8 @@ from hub.city_model_structure.energy_systems.distribution_system import Distribu
|
|||||||
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
||||||
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
||||||
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||||
from hub.city_model_structure.energy_systems.generic_energy_system import GenericEnergySystem
|
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
||||||
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
|
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||||
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
||||||
from hub.helpers.dictionaries import Dictionaries
|
from hub.helpers.dictionaries import Dictionaries
|
||||||
|
|
||||||
@ -79,7 +79,7 @@ class NorthAmericaCustomEnergySystemParameters:
|
|||||||
data = [archetype.name, building.name]
|
data = [archetype.name, building.name]
|
||||||
_energy_systems_connection_table.loc[len(_energy_systems_connection_table)] = data
|
_energy_systems_connection_table.loc[len(_energy_systems_connection_table)] = data
|
||||||
for system in archetype.systems:
|
for system in archetype.systems:
|
||||||
energy_system = GenericEnergySystem()
|
energy_system = EnergySystem()
|
||||||
_hub_demand_types = []
|
_hub_demand_types = []
|
||||||
demand_types = system.demand_types
|
demand_types = system.demand_types
|
||||||
if isinstance(demand_types, str):
|
if isinstance(demand_types, str):
|
||||||
@ -91,7 +91,7 @@ class NorthAmericaCustomEnergySystemParameters:
|
|||||||
archetype_generation_equipments = system.generation_systems
|
archetype_generation_equipments = system.generation_systems
|
||||||
_generation_systems = []
|
_generation_systems = []
|
||||||
for archetype_generation_equipment in archetype_generation_equipments:
|
for archetype_generation_equipment in archetype_generation_equipments:
|
||||||
_generation_system = GenericGenerationSystem()
|
_generation_system = GenerationSystem()
|
||||||
_type = archetype_generation_equipment.name
|
_type = archetype_generation_equipment.name
|
||||||
_generation_system.type = Dictionaries().north_america_system_to_hub_energy_generation_system[_type]
|
_generation_system.type = Dictionaries().north_america_system_to_hub_energy_generation_system[_type]
|
||||||
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
|
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
|
||||||
|
@ -9,6 +9,7 @@ import subprocess
|
|||||||
from pathlib import Path
|
from pathlib import Path
|
||||||
from unittest import TestCase
|
from unittest import TestCase
|
||||||
import copy
|
import copy
|
||||||
|
from typing import cast
|
||||||
|
|
||||||
import hub.helpers.constants as cte
|
import hub.helpers.constants as cte
|
||||||
from hub.exports.energy_building_exports_factory import EnergyBuildingsExportsFactory
|
from hub.exports.energy_building_exports_factory import EnergyBuildingsExportsFactory
|
||||||
@ -25,6 +26,8 @@ from hub.city_model_structure.energy_systems.generation_system import Generation
|
|||||||
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
||||||
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
||||||
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
||||||
|
from hub.city_model_structure.energy_systems.non_pv_generation_system import NonPvGenerationSystem
|
||||||
|
|
||||||
|
|
||||||
class TestSystemsFactory(TestCase):
|
class TestSystemsFactory(TestCase):
|
||||||
"""
|
"""
|
||||||
@ -54,7 +57,6 @@ class TestSystemsFactory(TestCase):
|
|||||||
building.energy_systems_archetype_name = 'system 1 gas'
|
building.energy_systems_archetype_name = 'system 1 gas'
|
||||||
|
|
||||||
EnergySystemsFactory('montreal_custom', self._city).enrich()
|
EnergySystemsFactory('montreal_custom', self._city).enrich()
|
||||||
self.assertEqual(17, len(self._city.energy_systems_connection_table))
|
|
||||||
self.assertEqual(1, len(self._city.generic_energy_systems))
|
self.assertEqual(1, len(self._city.generic_energy_systems))
|
||||||
|
|
||||||
def test_montreal_custom_system_results(self):
|
def test_montreal_custom_system_results(self):
|
||||||
@ -78,39 +80,15 @@ class TestSystemsFactory(TestCase):
|
|||||||
building.energy_systems_archetype_name = 'system 1 gas pv'
|
building.energy_systems_archetype_name = 'system 1 gas pv'
|
||||||
EnergySystemsFactory('montreal_custom', self._city).enrich()
|
EnergySystemsFactory('montreal_custom', self._city).enrich()
|
||||||
# Need to assign energy systems to buildings:
|
# Need to assign energy systems to buildings:
|
||||||
energy_systems_connection = self._city.energy_systems_connection_table
|
|
||||||
for building in self._city.buildings:
|
for building in self._city.buildings:
|
||||||
_building_energy_systems = []
|
_building_energy_systems = []
|
||||||
energy_systems = energy_systems_connection['Energy System Type'][
|
for energy_system in building.energy_systems:
|
||||||
energy_systems_connection['Building'] == building.name]
|
if cte.HEATING in energy_system.demand_types:
|
||||||
for energy_system in energy_systems:
|
_generation_system = cast(NonPvGenerationSystem, energy_system.generation_systems[0])
|
||||||
_generic_building_energy_systems = self._city.generic_energy_systems[energy_system]
|
_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
||||||
for _generic_building_energy_system in _generic_building_energy_systems:
|
if cte.COOLING in energy_system.demand_types:
|
||||||
_building_energy_equipment = EnergySystem()
|
_generation_system = cast(NonPvGenerationSystem, energy_system.generation_systems[0])
|
||||||
_building_energy_equipment.demand_types = _generic_building_energy_system.demand_types
|
_generation_system.cooling_power = building.cooling_peak_load[cte.YEAR][0]
|
||||||
|
|
||||||
_building_distribution_system = DistributionSystem()
|
|
||||||
_building_distribution_system.generic_distribution_system = (
|
|
||||||
copy.deepcopy(_generic_building_energy_system.distribution_systems)
|
|
||||||
)
|
|
||||||
_building_emission_system = EmissionSystem()
|
|
||||||
_building_emission_system.generic_emission_system = (
|
|
||||||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
|
||||||
)
|
|
||||||
_building_generation_system = GenerationSystem()
|
|
||||||
_building_generation_system.generic_generation_system = (
|
|
||||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
|
||||||
)
|
|
||||||
if cte.HEATING in _building_energy_equipment.demand_types:
|
|
||||||
_building_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
|
||||||
if cte.COOLING in _building_energy_equipment.demand_types:
|
|
||||||
_building_generation_system.cooling_power = building.cooling_peak_load[cte.YEAR][0]
|
|
||||||
_building_energy_equipment.generation_systems = _building_generation_system
|
|
||||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
|
||||||
_building_energy_equipment.emission_systems = _building_emission_system
|
|
||||||
|
|
||||||
_building_energy_systems.append(_building_energy_equipment)
|
|
||||||
building.energy_systems = _building_energy_systems
|
|
||||||
|
|
||||||
for building in self._city.buildings:
|
for building in self._city.buildings:
|
||||||
self.assertLess(0, building.heating_consumption[cte.YEAR][0])
|
self.assertLess(0, building.heating_consumption[cte.YEAR][0])
|
||||||
|
Loading…
Reference in New Issue
Block a user