forked from s_ranjbar/city_retrofit
added first example of possible catalog.xml
This commit is contained in:
parent
53aa540b45
commit
688198a3fb
|
@ -5,6 +5,8 @@ Copyright © 2023 Concordia CERC group
|
|||
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||
"""
|
||||
|
||||
from __future__ import annotations
|
||||
|
||||
|
||||
class GenerationSystem:
|
||||
def __init__(self, system_type, fuel_type, source_types, heat_efficiency, cooling_efficiency, electricity_efficiency,
|
||||
|
|
|
@ -1,5 +1,125 @@
|
|||
<archetypes>
|
||||
<archetype name="boiler" lod="1" demands="[heating, domestic_hot_water]">
|
||||
|
||||
</archetype>
|
||||
</archetypes>
|
||||
<catalog lod="1">
|
||||
<equipments>
|
||||
<equipment id="1" type="boiler" fuel_type="gas">
|
||||
<name>Fuel-fired water boiler with baseboards</name>
|
||||
<demands>
|
||||
<demand>heating</demand>
|
||||
<demand>domestic_hot_water</demand>
|
||||
</demands>
|
||||
<heating_efficiency>0.85</heating_efficiency>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption units="%">2</distribution_consumption>
|
||||
<storage>true</storage>
|
||||
</equipment>
|
||||
<equipment id="2" type="boiler" fuel_type="electricity">
|
||||
<name>Electrical resistance water boiler</name>
|
||||
<demands>
|
||||
<demand>heating</demand>
|
||||
<demand>domestic_hot_water</demand>
|
||||
</demands>
|
||||
<heating_efficiency>1</heating_efficiency>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption units="%">2</distribution_consumption>
|
||||
<storage>true</storage>
|
||||
</equipment>
|
||||
<equipment id="3" type="furnace" fuel_type="gas">
|
||||
<name>Fuel-fired furnace</name>
|
||||
<demands>
|
||||
<demand>heating</demand>
|
||||
</demands>
|
||||
<heating_efficiency>0.85</heating_efficiency>
|
||||
<distribution_heat_losses units="%">25</distribution_heat_losses>
|
||||
<distribution_consumption units="%">5</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="4" type="furnace" fuel_type="electricity">
|
||||
<name>Electrical resistance furnace</name>
|
||||
<demands>
|
||||
<demand>heating</demand>
|
||||
</demands>
|
||||
<heating_efficiency>1</heating_efficiency>
|
||||
<distribution_heat_losses units="%">25</distribution_heat_losses>
|
||||
<distribution_consumption units="%">5</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="5" type="baseboard" fuel_type="gas">
|
||||
<name>Baseboards: hydronic with fuel boiler</name>
|
||||
<demands>
|
||||
<demand>heating</demand>
|
||||
</demands>
|
||||
<heating_efficiency>0.85</heating_efficiency>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption units="%">5</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="6" type="baseboard" fuel_type="electricity">
|
||||
<name>Electrical baseboards</name>
|
||||
<demands>
|
||||
<demand>heating</demand>
|
||||
</demands>
|
||||
<heating_efficiency>1</heating_efficiency>
|
||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
||||
<distribution_consumption units="%">0</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="7" type="cooler" fuel_type="electricity">
|
||||
<name>Air cooled DX with external condenser</name>
|
||||
<demands>
|
||||
<demand>cooling</demand>
|
||||
</demands>
|
||||
<cooling_efficiency>3.23</cooling_efficiency>
|
||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
||||
<distribution_consumption units="%">5</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="8" type="cooler" fuel_type="electricity">
|
||||
<name>Water cooled, water chiller</name>
|
||||
<demands>
|
||||
<demand>cooling</demand>
|
||||
</demands>
|
||||
<cooling_efficiency>3.23</cooling_efficiency>
|
||||
<distribution_heat_losses units="%">10</distribution_heat_losses>
|
||||
<distribution_consumption units="%">5</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="9" type="cooler" fuel_type="electricity">
|
||||
<name>Air cooled DX</name>
|
||||
<demands>
|
||||
<demand>cooling</demand>
|
||||
</demands>
|
||||
<cooling_efficiency>3.23</cooling_efficiency>
|
||||
<distribution_heat_losses units="%">0</distribution_heat_losses>
|
||||
<distribution_consumption units="%">5</distribution_consumption>
|
||||
<storage>false</storage>
|
||||
</equipment>
|
||||
<equipment id="10" type="electricity generator" fuel_type="renewable">
|
||||
<name>PV system</name>
|
||||
<demands>
|
||||
<demand>electricity</demand>
|
||||
</demands>
|
||||
<electrical_efficiency>0.22</electrical_efficiency>
|
||||
<storage>true</storage>
|
||||
</equipment>
|
||||
</equipments>
|
||||
<systems>
|
||||
<system name="system 1 gas">
|
||||
<equipments>
|
||||
<equipment_id>1</equipment_id>
|
||||
<equipment_id>7</equipment_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system name="system 1 electricity">
|
||||
<equipments>
|
||||
<equipment_id>2</equipment_id>
|
||||
<equipment_id>7</equipment_id>
|
||||
</equipments>
|
||||
</system>
|
||||
<system name="system 1 electricity pv">
|
||||
<equipments>
|
||||
<equipment_id>2</equipment_id>
|
||||
<equipment_id>7</equipment_id>
|
||||
<equipment_id>10</equipment_id>
|
||||
</equipments>
|
||||
</system>
|
||||
</systems>
|
||||
</catalog>
|
Loading…
Reference in New Issue
Block a user