Changed idf to start producing detailed systems

This commit is contained in:
Oriol Gavalda 2023-11-16 14:26:41 -05:00
parent 5fa55ea79f
commit a3c5219ccd
3 changed files with 150 additions and 6 deletions

View File

@ -54,6 +54,7 @@ class Idf:
_SIZING_PERIODS = 'SIZINGPERIOD:DESIGNDAY'
_LOCATION = 'SITE:LOCATION'
_SIMPLE = 'Simple'
_EQUIPMENT_CONNECTIONS = 'ZONEHVAC:EQUIPMENTCONNECTIONS'
idf_surfaces = {
cte.WALL: 'wall',
@ -385,12 +386,13 @@ class Idf:
if air_system.Zone_Name == zone_name:
return
thermostat = self._add_thermostat(thermal_zone)
self._idf.newidfobject(self._IDEAL_LOAD_AIR_SYSTEM,
self._idf.newidfobject(self._EQUIPMENT_CONNECTIONS,
Zone_Name=zone_name,
System_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
Heating_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
Cooling_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
Template_Thermostat_Name=thermostat.Name)
Zone_Conditioning_Equipment_List_Name=f'{thermal_zone.usage_name} Equipment List',
Zone_Air_Inlet_Node_or_NodeList_Name=f'{thermal_zone.usage_name} Inlet Node List',
Zone_Air_Node_Name=f'Node 1',
Zone_Return_Air_Node_or_NodeList_Name=f'{thermal_zone.usage_name} Return Node List')
def _add_occupancy(self, thermal_zone, zone_name):
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area

View File

@ -1,4 +1,4 @@
"""
"""
TestExports test and validate the city export formats
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group

142
texttest Normal file
View File

@ -0,0 +1,142 @@
ZoneControl:Thermostat,
Room_180_7ad8616b Thermostat, !- Name
Room_180_7ad8616b, !- Zone or ZoneList Name
Room_180_7ad8616b Thermostat Schedule, !- Control Type Schedule Name
ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
LargeOffice Building_Setpoint 26, !- Control 1 Name
, !- Control 2 Object Type
, !- Control 2 Name
, !- Control 3 Object Type
, !- Control 3 Name
, !- Control 4 Object Type
, !- Control 4 Name
0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
Schedule:Compact,
Room_180_7ad8616b Thermostat Schedule, !- Name
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Schedule Type Limits Name
Through: 12/31, !- Field 1
For: AllDays, !- Field 2
Until: 24:00, !- Field 3
4; !- Field 4
ScheduleTypeLimits,
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Name
0, !- Lower Limit Value {BasedOnField A3}
4, !- Upper Limit Value {BasedOnField A3}
DISCRETE; !- Numeric Type
ThermostatSetpoint:DualSetpoint,
LargeOffice Building_Setpoint 26, !- Name
LargeOffice Building_Setpoint_HtgSetp Schedule, !- Heating Setpoint Temperature Schedule Name
LargeOffice Building_Setpoint_ClgSetp Schedule; !- Cooling Setpoint Temperature Schedule Name
ZoneHVAC:EquipmentConnections,
Room_180_7ad8616b, !- Zone Name
Room_180_7ad8616b Equipment List, !- Zone Conditioning Equipment List Name
Room_180_7ad8616b Inlet Node List, !- Zone Air Inlet Node or NodeList Name
, !- Zone Air Exhaust Node or NodeList Name
Node 27, !- Zone Air Node Name
Room_180_7ad8616b Return Node List; !- Zone Return Air Node or NodeList Name
NodeList,
Room_180_7ad8616b Inlet Node List, !- Name
Node 305; !- Node Name 1
NodeList,
Room_180_7ad8616b Return Node List, !- Name
Node 308; !- Node Name 1
ZoneHVAC:Baseboard:Convective:Electric,
Elec Baseboard 1, !- Name
Always On Discrete hvac_library, !- Availability Schedule Name
, !- Heating Design Capacity Method
Autosize, !- Heating Design Capacity {W}
, !- Heating Design Capacity Per Floor Area {W/m2}
, !- Fraction of Autosized Heating Design Capacity
1; !- Efficiency
AirTerminal:SingleDuct:ConstantVolume:NoReheat,
Diffuser 21, !- Name
Always On Discrete hvac_library, !- Availability Schedule Name
Node 307, !- Air Inlet Node Name
Node 305, !- Air Outlet Node Name
AutoSize; !- Maximum Air Flow Rate {m3/s}
ZoneHVAC:AirDistributionUnit,
ADU Diffuser 21, !- Name
Node 305, !- Air Distribution Unit Outlet Node Name
AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type
Diffuser 21; !- Air Terminal Name
ZoneHVAC:EquipmentList,
Room_180_7ad8616b Equipment List, !- Name
SequentialLoad, !- Load Distribution Scheme
ZoneHVAC:Baseboard:Convective:Electric, !- Zone Equipment Object Type 1
Elec Baseboard 1, !- Zone Equipment Name 1
1, !- Zone Equipment Cooling Sequence 1
1, !- Zone Equipment Heating or No-Load Sequence 1
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 1
, !- Zone Equipment Sequential Heating Fraction Schedule Name 1
ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type 2
ADU Diffuser 21, !- Zone Equipment Name 2
2, !- Zone Equipment Cooling Sequence 2
2, !- Zone Equipment Heating or No-Load Sequence 2
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 2
; !- Zone Equipment Sequential Heating Fraction Schedule Name 2
Sizing:Zone,
Room_180_7ad8616b, !- Zone or ZoneList Name
SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
14, !- Zone Cooling Design Supply Air Temperature {C}
11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
40, !- Zone Heating Design Supply Air Temperature {C}
11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
Room_180_7ad8616b DSOA Space List, !- Design Specification Outdoor Air Object Name
, !- Zone Heating Sizing Factor
, !- Zone Cooling Sizing Factor
DesignDay, !- Cooling Design Air Flow Method
0, !- Cooling Design Air Flow Rate {m3/s}
0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
0, !- Cooling Minimum Air Flow {m3/s}
0, !- Cooling Minimum Air Flow Fraction
DesignDay, !- Heating Design Air Flow Method
0, !- Heating Design Air Flow Rate {m3/s}
0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
0.1415762, !- Heating Maximum Air Flow {m3/s}
0.3, !- Heating Maximum Air Flow Fraction
, !- Design Specification Zone Air Distribution Object Name
No, !- Account for Dedicated Outdoor Air System
, !- Dedicated Outdoor Air System Control Strategy
, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C}
, !- Dedicated Outdoor Air High Setpoint Temperature for Design {C}
Sensible Load Only No Latent Load, !- Zone Load Sizing Method
HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method
, !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method
, !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
DesignSpecification:OutdoorAir:SpaceList,
Room_180_7ad8616b DSOA Space List, !- Name
Room_180_7ad8616b_Space, !- Space Name 1
MidriseApartment Apartment Ventilation; !- Space Design Specification Outdoor Air Object Name 1
Zone,
Room_181_3a411b5d, !- Name
, !- Direction of Relative North {deg}
0, !- X Origin {m}
0, !- Y Origin {m}
0, !- Z Origin {m}
, !- Type
1, !- Multiplier
4, !- Ceiling Height {m}
291.62935408288, !- Volume {m3}
, !- Floor Area {m2}
, !- Zone Inside Convection Algorithm
, !- Zone Outside Convection Algorithm
Yes; !- Part of Total Floor Area