forked from s_ranjbar/city_retrofit
Tried to modify the test_systems_factory.py but received an error saying GenerationSystem object is not iterable
This commit is contained in:
parent
f0ad1462d0
commit
cbda6ce13d
|
@ -744,15 +744,18 @@ class Building(CityObject):
|
|||
if self.energy_systems is None:
|
||||
return None
|
||||
for energy_system in self.energy_systems:
|
||||
generation_systems = energy_system.generation_system
|
||||
for demand_type in energy_system.demand_types:
|
||||
if demand_type.lower() == consumption_type.lower():
|
||||
if consumption_type in (cte.HEATING, cte.DOMESTIC_HOT_WATER):
|
||||
coefficient_of_performance = energy_system.generation_system.generic_generation_system.heat_efficiency
|
||||
for generation_system in generation_systems:
|
||||
coefficient_of_performance = generation_system.generic_generation_system.heat_efficiency
|
||||
elif consumption_type == cte.COOLING:
|
||||
coefficient_of_performance = energy_system.generation_system.generic_generation_system.cooling_efficiency
|
||||
for generation_system in generation_systems:
|
||||
coefficient_of_performance = generation_system.generic_generation_system.cooling_efficiency
|
||||
elif consumption_type == cte.ELECTRICITY:
|
||||
coefficient_of_performance = \
|
||||
energy_system.generation_system.generic_generation_system.electricity_efficiency
|
||||
for generation_system in generation_systems:
|
||||
coefficient_of_performance = generation_system.generic_generation_system.electricity_efficiency
|
||||
if coefficient_of_performance == 0:
|
||||
values = [0]*len(demand)
|
||||
final_energy_consumed = values
|
||||
|
|
|
@ -161,16 +161,20 @@ class TestSystemsFactory(TestCase):
|
|||
|
||||
_building_distribution_system = DistributionSystem()
|
||||
_building_distribution_system.generic_distribution_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_systems)
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_system)
|
||||
)
|
||||
_building_emission_system = EmissionSystem()
|
||||
_building_emission_system.generic_emission_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
||||
copy.deepcopy(_generic_building_energy_system.emission_system)
|
||||
)
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.generation_system)
|
||||
)
|
||||
_building_storage_system = ThermalStorageSystem()
|
||||
_building_storage_system.generic_storage_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_system)
|
||||
|
||||
if cte.HEATING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
||||
if cte.COOLING in _building_energy_equipment.demand_types:
|
||||
|
|
Loading…