Commit Graph

90 Commits

Author SHA1 Message Date
ee58d21b47 solved some small errors in meb exporter 2023-05-23 17:19:50 -04:00
c77c03b759 Incorporation of ventilation that previously was not writing idf. Working.
Incorporation of percentual losses in distribution
2023-05-19 18:05:36 -04:00
3680e0356f Merge branch 'idf_lights' into systems_catalog 2023-05-19 11:21:12 -04:00
7b245a69b3 Incorporation of ventilation. Working. 2023-05-19 11:20:44 -04:00
e48dec81cf added lod to the city_objects 2023-05-12 09:27:29 -04:00
0747b61294 some formatting 2023-05-03 16:16:50 -04:00
f060197729 cleaned a bug in add_schedules and erased all related to adjacent_buildings 2023-05-03 14:14:13 -04:00
bdb8bf65b7 continue cleaning idf exporter. Changed all specific schedules to general _add_schedule by previously creating the schedules 2023-05-03 13:05:37 -04:00
91e2794a8b Merge remote-tracking branch 'origin/idf_lights' into idf_lights
# Conflicts:
#	hub/catalog_factories/usage/nrcan_catalog.py
#	hub/exports/building_energy/idf.py
2023-05-03 11:50:59 -04:00
d82ada6240 solved bug in nrcan catalog and partially cleaned ep exporter 2023-05-03 11:39:32 -04:00
75e56f4b99 Ventilation and usage changed, problem of units. Revise with Pilar the incorporation of ventilation 2023-05-02 17:51:08 -04:00
27549e784d Merge branch 'geojson' into idf_lights 2023-05-02 14:47:26 -04:00
de718456a5 just changed a comment 2023-05-02 14:47:10 -04:00
7a6bf0ac52 rolled back some changes and hardcoded values 2023-05-02 14:44:45 -04:00
9ecf59c68f rolled back some changes and hardcoded values 2023-05-02 14:39:37 -04:00
1e68319e7e partial re-implementation of geojson read. 2023-05-01 18:05:09 -04:00
949a6c268f complete peak loads calculation 2023-05-01 10:37:51 -04:00
e4b6c54af6 Partial correction for peakloads 2023-04-27 10:59:03 -04:00
78b21093bb DHW bug solved. It had to do with the factor of the building surface. Now getting good results 2023-04-25 08:24:56 -04:00
dc6bfb3403 correct idf generation for shared walls 2023-04-18 16:47:36 -04:00
90c40f5e55 add shared surfaces to idf 2023-04-18 15:45:09 -04:00
a59ef0937d Outputs of DHW incorporated. Values still relatively high, but consistent. Still need to incorporate adequately Cold Water Temperature 2023-04-17 10:12:18 -04:00
fe7f44d51f Fully functional Domestic Hot Water. Pending validation of results 2023-04-12 13:52:55 -04:00
f62df2e873 dhw schedule fix attempt 2023-04-12 10:16:14 -04:00
89faa92103 dhw schedule fix attempt 2023-04-12 09:35:27 -04:00
40fe325a18 Incorporated 1st version Domestic Hot Water, still not working. 2023-04-11 23:07:56 -04:00
6de00c0331 Change of minimal.idf to include monthly summary of data to be able to compare with MEP.
Commenting the EP-Workflow to solve the error given by the output reader. To be solved with Koa
2023-04-04 17:59:20 -04:00
bc0c1fc0f3 Revision of infiltration parameters 2023-03-31 12:25:13 -04:00
648548ea2c Merge branch 'main' into idf_lights
# Conflicts:
#	hub/exports/building_energy/idf.py
#	hub/unittests/test_exports.py
2023-03-27 16:39:30 -04:00
7a9032b0dc Small refactor.
Now energy plus don't raise and unexpected error when some exports aren't performed.
2023-03-27 16:28:17 -04:00
dde1c796f7 Merge pull request 'test_correction' (#18) from test_correction into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/18
2023-03-27 13:56:55 -04:00
47d9d9d775 Correct all the unit tests 2023-03-27 13:55:32 -04:00
26951d2458 Remove un used variable 2023-03-27 11:40:39 -04:00
27005e20c9 Correct missing information 2023-03-27 11:39:45 -04:00
9ed8fc61e2 Changes in idf. 2023-03-27 11:25:43 -04:00
f5987cfbcc solved bug in ventilation + infiltration calculation 2023-03-24 13:34:37 -04:00
f48d5214f4 Changes idf to incorporate multifloor 2023-03-24 12:15:10 -04:00
f8b33fa5bf Small improvement in idf export for lighting 2023-03-24 09:33:09 -04:00
812d8d06d2 Schedule appliances added
First trial of adding factor to change from multizone to unizone. Commented.
2023-03-24 08:10:47 -04:00
5096fe3bab Usage fzk hous in exoport idf 2023-03-23 15:47:31 -04:00
50ec57f04f Correct IDF 2023-03-23 13:43:03 -04:00
b918dfcabd added dhw and electrical demand to results importer and sanity check to importer 2023-03-23 13:33:25 -04:00
35f5544a32 Appliances test 2023-03-23 13:24:41 -04:00
9d51d4f8ba idf 2023-03-22 16:23:43 -04:00
a3bbe76147 Merge pull request 'meb_debugging' (#11) from meb_debugging into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/11
2023-03-22 10:37:44 -04:00
28dd0f8b0f fixed the tcold bug 2023-03-21 16:11:58 -04:00
f3db1e5fee reviewed units in nrcan catalog and modified catalog and importer accordingly 2023-03-21 15:29:11 -04:00
4b3ce016b2 remove jit 2023-03-17 13:40:14 -04:00
d979c74b8d partial; optimization 2023-03-17 13:36:43 -04:00
Pilar
05dcc7a4fb Merge branch 'main' into debuging_meb 2023-03-16 15:56:46 -04:00