ZoneControl:Thermostat, Room_180_7ad8616b Thermostat, !- Name Room_180_7ad8616b, !- Zone or ZoneList Name Room_180_7ad8616b Thermostat Schedule, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type LargeOffice Building_Setpoint 26, !- Control 1 Name , !- Control 2 Object Type , !- Control 2 Name , !- Control 3 Object Type , !- Control 3 Name , !- Control 4 Object Type , !- Control 4 Name 0; !- Temperature Difference Between Cutout And Setpoint {deltaC} Schedule:Compact, Room_180_7ad8616b Thermostat Schedule, !- Name Room_180_7ad8616b Thermostat Schedule Type Limits, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00, !- Field 3 4; !- Field 4 ScheduleTypeLimits, Room_180_7ad8616b Thermostat Schedule Type Limits, !- Name 0, !- Lower Limit Value {BasedOnField A3} 4, !- Upper Limit Value {BasedOnField A3} DISCRETE; !- Numeric Type ThermostatSetpoint:DualSetpoint, LargeOffice Building_Setpoint 26, !- Name LargeOffice Building_Setpoint_HtgSetp Schedule, !- Heating Setpoint Temperature Schedule Name LargeOffice Building_Setpoint_ClgSetp Schedule; !- Cooling Setpoint Temperature Schedule Name ZoneHVAC:EquipmentConnections, Room_180_7ad8616b, !- Zone Name Room_180_7ad8616b Equipment List, !- Zone Conditioning Equipment List Name Room_180_7ad8616b Inlet Node List, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Node 27, !- Zone Air Node Name Room_180_7ad8616b Return Node List; !- Zone Return Air Node or NodeList Name NodeList, Room_180_7ad8616b Inlet Node List, !- Name Node 305; !- Node Name 1 NodeList, Room_180_7ad8616b Return Node List, !- Name Node 308; !- Node Name 1 ZoneHVAC:Baseboard:Convective:Electric, Elec Baseboard 1, !- Name Always On Discrete hvac_library, !- Availability Schedule Name , !- Heating Design Capacity Method Autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity 1; !- Efficiency AirTerminal:SingleDuct:ConstantVolume:NoReheat, Diffuser 21, !- Name Always On Discrete hvac_library, !- Availability Schedule Name Node 307, !- Air Inlet Node Name Node 305, !- Air Outlet Node Name AutoSize; !- Maximum Air Flow Rate {m3/s} ZoneHVAC:AirDistributionUnit, ADU Diffuser 21, !- Name Node 305, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type Diffuser 21; !- Air Terminal Name ZoneHVAC:EquipmentList, Room_180_7ad8616b Equipment List, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:Baseboard:Convective:Electric, !- Zone Equipment Object Type 1 Elec Baseboard 1, !- Zone Equipment Name 1 1, !- Zone Equipment Cooling Sequence 1 1, !- Zone Equipment Heating or No-Load Sequence 1 , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 , !- Zone Equipment Sequential Heating Fraction Schedule Name 1 ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type 2 ADU Diffuser 21, !- Zone Equipment Name 2 2, !- Zone Equipment Cooling Sequence 2 2, !- Zone Equipment Heating or No-Load Sequence 2 , !- Zone Equipment Sequential Cooling Fraction Schedule Name 2 ; !- Zone Equipment Sequential Heating Fraction Schedule Name 2 Sizing:Zone, Room_180_7ad8616b, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 14, !- Zone Cooling Design Supply Air Temperature {C} 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40, !- Zone Heating Design Supply Air Temperature {C} 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} Room_180_7ad8616b DSOA Space List, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDay, !- Cooling Design Air Flow Method 0, !- Cooling Design Air Flow Rate {m3/s} 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0, !- Heating Design Air Flow Rate {m3/s} 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} 0.1415762, !- Heating Maximum Air Flow {m3/s} 0.3, !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System , !- Dedicated Outdoor Air System Control Strategy , !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} , !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} Sensible Load Only No Latent Load, !- Zone Load Sizing Method HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method , !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir} HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method , !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir} DesignSpecification:OutdoorAir:SpaceList, Room_180_7ad8616b DSOA Space List, !- Name Room_180_7ad8616b_Space, !- Space Name 1 MidriseApartment Apartment Ventilation; !- Space Design Specification Outdoor Air Object Name 1 Zone, Room_181_3a411b5d, !- Name , !- Direction of Relative North {deg} 0, !- X Origin {m} 0, !- Y Origin {m} 0, !- Z Origin {m} , !- Type 1, !- Multiplier 4, !- Ceiling Height {m} 291.62935408288, !- Volume {m3} , !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area