fix: latest Oriol changes and some updates in energy system catalog are implemented
This commit is contained in:
parent
73b779747e
commit
57cefc2f30
|
@ -126,6 +126,10 @@ class EilatCatalog(Catalog):
|
||||||
'infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
|
'infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
|
||||||
infiltration_rate_for_ventilation_system_on = archetype[
|
infiltration_rate_for_ventilation_system_on = archetype[
|
||||||
'infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
'infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
||||||
|
infiltration_rate_area_for_ventilation_system_off = archetype[
|
||||||
|
'infiltration_rate_area_for_ventilation_system_off']
|
||||||
|
infiltration_rate_area_for_ventilation_system_on = archetype[
|
||||||
|
'infiltration_rate_area_for_ventilation_system_on']
|
||||||
|
|
||||||
archetype_constructions = []
|
archetype_constructions = []
|
||||||
for archetype_construction in archetype['constructions']:
|
for archetype_construction in archetype['constructions']:
|
||||||
|
@ -164,8 +168,8 @@ class EilatCatalog(Catalog):
|
||||||
None,
|
None,
|
||||||
infiltration_rate_for_ventilation_system_off,
|
infiltration_rate_for_ventilation_system_off,
|
||||||
infiltration_rate_for_ventilation_system_on,
|
infiltration_rate_for_ventilation_system_on,
|
||||||
0,
|
infiltration_rate_area_for_ventilation_system_off,
|
||||||
0))
|
infiltration_rate_area_for_ventilation_system_on))
|
||||||
return _catalog_archetypes
|
return _catalog_archetypes
|
||||||
|
|
||||||
def names(self, category=None):
|
def names(self, category=None):
|
||||||
|
|
|
@ -129,6 +129,12 @@ class NrelCatalog(Catalog):
|
||||||
infiltration_rate_for_ventilation_system_on = float(
|
infiltration_rate_for_ventilation_system_on = float(
|
||||||
archetype['infiltration_rate_for_ventilation_system_on']['#text']
|
archetype['infiltration_rate_for_ventilation_system_on']['#text']
|
||||||
) / cte.HOUR_TO_SECONDS
|
) / cte.HOUR_TO_SECONDS
|
||||||
|
infiltration_rate_area_for_ventilation_system_off = float(
|
||||||
|
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
|
||||||
|
)
|
||||||
|
infiltration_rate_area_for_ventilation_system_on = float(
|
||||||
|
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
|
||||||
|
)
|
||||||
|
|
||||||
archetype_constructions = []
|
archetype_constructions = []
|
||||||
for archetype_construction in archetype['constructions']['construction']:
|
for archetype_construction in archetype['constructions']['construction']:
|
||||||
|
@ -163,8 +169,8 @@ class NrelCatalog(Catalog):
|
||||||
indirect_heated_ratio,
|
indirect_heated_ratio,
|
||||||
infiltration_rate_for_ventilation_system_off,
|
infiltration_rate_for_ventilation_system_off,
|
||||||
infiltration_rate_for_ventilation_system_on,
|
infiltration_rate_for_ventilation_system_on,
|
||||||
0,
|
infiltration_rate_area_for_ventilation_system_off,
|
||||||
0))
|
infiltration_rate_area_for_ventilation_system_on))
|
||||||
return _catalog_archetypes
|
return _catalog_archetypes
|
||||||
|
|
||||||
def names(self, category=None):
|
def names(self, category=None):
|
||||||
|
|
|
@ -15,11 +15,20 @@ class Archetype:
|
||||||
"""
|
"""
|
||||||
Archetype class
|
Archetype class
|
||||||
"""
|
"""
|
||||||
def __init__(self, name, systems):
|
|
||||||
|
|
||||||
|
def __init__(self, name, systems, archetype_cluster_id=None):
|
||||||
|
self._cluster_id = archetype_cluster_id
|
||||||
self._name = name
|
self._name = name
|
||||||
self._systems = systems
|
self._systems = systems
|
||||||
|
|
||||||
|
@property
|
||||||
|
def cluster_id(self):
|
||||||
|
"""
|
||||||
|
Get id
|
||||||
|
:return: string
|
||||||
|
"""
|
||||||
|
return self._cluster_id
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def name(self):
|
def name(self):
|
||||||
"""
|
"""
|
||||||
|
@ -43,6 +52,7 @@ class Archetype:
|
||||||
_systems.append(_system.to_dictionary())
|
_systems.append(_system.to_dictionary())
|
||||||
content = {
|
content = {
|
||||||
'Archetype': {
|
'Archetype': {
|
||||||
|
'cluster_id': self.cluster_id,
|
||||||
'name': self.name,
|
'name': self.name,
|
||||||
'systems': _systems
|
'systems': _systems
|
||||||
}
|
}
|
||||||
|
|
|
@ -20,7 +20,7 @@ class GenerationSystem(ABC):
|
||||||
"""
|
"""
|
||||||
|
|
||||||
def __init__(self, system_id, name, model_name=None, manufacturer=None, fuel_type=None,
|
def __init__(self, system_id, name, model_name=None, manufacturer=None, fuel_type=None,
|
||||||
distribution_systems=None, energy_storage_systems=None):
|
distribution_systems=None, energy_storage_systems=None, number_of_units=None):
|
||||||
self._system_id = system_id
|
self._system_id = system_id
|
||||||
self._name = name
|
self._name = name
|
||||||
self._model_name = model_name
|
self._model_name = model_name
|
||||||
|
@ -28,6 +28,7 @@ class GenerationSystem(ABC):
|
||||||
self._fuel_type = fuel_type
|
self._fuel_type = fuel_type
|
||||||
self._distribution_systems = distribution_systems
|
self._distribution_systems = distribution_systems
|
||||||
self._energy_storage_systems = energy_storage_systems
|
self._energy_storage_systems = energy_storage_systems
|
||||||
|
self._number_of_units = number_of_units
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def id(self):
|
def id(self):
|
||||||
|
|
|
@ -17,8 +17,9 @@ class PvGenerationSystem(GenerationSystem):
|
||||||
def __init__(self, system_id, name, system_type, model_name=None, manufacturer=None, electricity_efficiency=None,
|
def __init__(self, system_id, name, system_type, model_name=None, manufacturer=None, electricity_efficiency=None,
|
||||||
nominal_electricity_output=None, nominal_ambient_temperature=None, nominal_cell_temperature=None,
|
nominal_electricity_output=None, nominal_ambient_temperature=None, nominal_cell_temperature=None,
|
||||||
nominal_radiation=None, standard_test_condition_cell_temperature=None,
|
nominal_radiation=None, standard_test_condition_cell_temperature=None,
|
||||||
standard_test_condition_maximum_power=None, cell_temperature_coefficient=None, width=None, height=None,
|
standard_test_condition_maximum_power=None, standard_test_condition_radiation=None,
|
||||||
distribution_systems=None, energy_storage_systems=None):
|
cell_temperature_coefficient=None, width=None, height=None, distribution_systems=None,
|
||||||
|
energy_storage_systems=None):
|
||||||
super().__init__(system_id=system_id, name=name, model_name=model_name,
|
super().__init__(system_id=system_id, name=name, model_name=model_name,
|
||||||
manufacturer=manufacturer, fuel_type='renewable', distribution_systems=distribution_systems,
|
manufacturer=manufacturer, fuel_type='renewable', distribution_systems=distribution_systems,
|
||||||
energy_storage_systems=energy_storage_systems)
|
energy_storage_systems=energy_storage_systems)
|
||||||
|
@ -30,6 +31,7 @@ class PvGenerationSystem(GenerationSystem):
|
||||||
self._nominal_radiation = nominal_radiation
|
self._nominal_radiation = nominal_radiation
|
||||||
self._standard_test_condition_cell_temperature = standard_test_condition_cell_temperature
|
self._standard_test_condition_cell_temperature = standard_test_condition_cell_temperature
|
||||||
self._standard_test_condition_maximum_power = standard_test_condition_maximum_power
|
self._standard_test_condition_maximum_power = standard_test_condition_maximum_power
|
||||||
|
self._standard_test_condition_radiation = standard_test_condition_radiation
|
||||||
self._cell_temperature_coefficient = cell_temperature_coefficient
|
self._cell_temperature_coefficient = cell_temperature_coefficient
|
||||||
self._width = width
|
self._width = width
|
||||||
self._height = height
|
self._height = height
|
||||||
|
@ -98,6 +100,15 @@ class PvGenerationSystem(GenerationSystem):
|
||||||
"""
|
"""
|
||||||
return self._standard_test_condition_maximum_power
|
return self._standard_test_condition_maximum_power
|
||||||
|
|
||||||
|
@property
|
||||||
|
def standard_test_condition_radiation(self):
|
||||||
|
"""
|
||||||
|
Get standard test condition cell temperature of PV panels in W/m2
|
||||||
|
:return: float
|
||||||
|
"""
|
||||||
|
return self._standard_test_condition_radiation
|
||||||
|
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def cell_temperature_coefficient(self):
|
def cell_temperature_coefficient(self):
|
||||||
"""
|
"""
|
||||||
|
@ -143,6 +154,7 @@ class PvGenerationSystem(GenerationSystem):
|
||||||
'nominal radiation [W/m2]': self.nominal_radiation,
|
'nominal radiation [W/m2]': self.nominal_radiation,
|
||||||
'standard test condition cell temperature [Celsius]': self.standard_test_condition_cell_temperature,
|
'standard test condition cell temperature [Celsius]': self.standard_test_condition_cell_temperature,
|
||||||
'standard test condition maximum power [W]': self.standard_test_condition_maximum_power,
|
'standard test condition maximum power [W]': self.standard_test_condition_maximum_power,
|
||||||
|
'standard test condition radiation [W/m2]': self.standard_test_condition_radiation,
|
||||||
'cell temperature coefficient': self.cell_temperature_coefficient,
|
'cell temperature coefficient': self.cell_temperature_coefficient,
|
||||||
'width': self.width,
|
'width': self.width,
|
||||||
'height': self.height,
|
'height': self.height,
|
||||||
|
|
|
@ -193,6 +193,7 @@ class MontrealFutureSystemCatalogue(Catalog):
|
||||||
nominal_radiation = pv['nominal_radiation']
|
nominal_radiation = pv['nominal_radiation']
|
||||||
standard_test_condition_cell_temperature = pv['standard_test_condition_cell_temperature']
|
standard_test_condition_cell_temperature = pv['standard_test_condition_cell_temperature']
|
||||||
standard_test_condition_maximum_power = pv['standard_test_condition_maximum_power']
|
standard_test_condition_maximum_power = pv['standard_test_condition_maximum_power']
|
||||||
|
standard_test_condition_radiation = pv['standard_test_condition_radiation']
|
||||||
cell_temperature_coefficient = pv['cell_temperature_coefficient']
|
cell_temperature_coefficient = pv['cell_temperature_coefficient']
|
||||||
width = pv['width']
|
width = pv['width']
|
||||||
height = pv['height']
|
height = pv['height']
|
||||||
|
@ -215,6 +216,7 @@ class MontrealFutureSystemCatalogue(Catalog):
|
||||||
standard_test_condition_cell_temperature=
|
standard_test_condition_cell_temperature=
|
||||||
standard_test_condition_cell_temperature,
|
standard_test_condition_cell_temperature,
|
||||||
standard_test_condition_maximum_power=standard_test_condition_maximum_power,
|
standard_test_condition_maximum_power=standard_test_condition_maximum_power,
|
||||||
|
standard_test_condition_radiation=standard_test_condition_radiation,
|
||||||
cell_temperature_coefficient=cell_temperature_coefficient,
|
cell_temperature_coefficient=cell_temperature_coefficient,
|
||||||
width=width,
|
width=width,
|
||||||
height=height,
|
height=height,
|
||||||
|
@ -379,6 +381,7 @@ class MontrealFutureSystemCatalogue(Catalog):
|
||||||
_system_archetypes = []
|
_system_archetypes = []
|
||||||
system_clusters = self._archetypes['EnergySystemCatalog']['system_archetypes']['system_archetype']
|
system_clusters = self._archetypes['EnergySystemCatalog']['system_archetypes']['system_archetype']
|
||||||
for system_cluster in system_clusters:
|
for system_cluster in system_clusters:
|
||||||
|
archetype_id = system_cluster['@cluster_id']
|
||||||
name = system_cluster['name']
|
name = system_cluster['name']
|
||||||
systems = system_cluster['systems']['system_id']
|
systems = system_cluster['systems']['system_id']
|
||||||
integer_system_ids = [int(item) for item in systems]
|
integer_system_ids = [int(item) for item in systems]
|
||||||
|
@ -386,7 +389,7 @@ class MontrealFutureSystemCatalogue(Catalog):
|
||||||
for system_archetype in self._systems:
|
for system_archetype in self._systems:
|
||||||
if int(system_archetype.id) in integer_system_ids:
|
if int(system_archetype.id) in integer_system_ids:
|
||||||
_systems.append(system_archetype)
|
_systems.append(system_archetype)
|
||||||
_system_archetypes.append(Archetype(name=name, systems=_systems))
|
_system_archetypes.append(Archetype(archetype_cluster_id=archetype_id, name=name, systems=_systems))
|
||||||
return _system_archetypes
|
return _system_archetypes
|
||||||
|
|
||||||
def _load_materials(self):
|
def _load_materials(self):
|
||||||
|
|
|
@ -92,7 +92,7 @@ class Building(CityObject):
|
||||||
logging.error('Building %s [%s] has an unexpected surface type %s.', self.name, self.aliases, surface.type)
|
logging.error('Building %s [%s] has an unexpected surface type %s.', self.name, self.aliases, surface.type)
|
||||||
self._domestic_hot_water_peak_load = None
|
self._domestic_hot_water_peak_load = None
|
||||||
self._fuel_consumption_breakdown = {}
|
self._fuel_consumption_breakdown = {}
|
||||||
self._pv_generation = {}
|
self._systems_archetype_cluster_id = None
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def shell(self) -> Polyhedron:
|
def shell(self) -> Polyhedron:
|
||||||
|
@ -880,8 +880,8 @@ class Building(CityObject):
|
||||||
storage_systems = generation_system.energy_storage_systems
|
storage_systems = generation_system.energy_storage_systems
|
||||||
if storage_systems:
|
if storage_systems:
|
||||||
for storage_system in storage_systems:
|
for storage_system in storage_systems:
|
||||||
if storage_system.type_energy_stored == 'thermal' and storage_system.heating_coil_energy_consumption:
|
if storage_system.type_energy_stored == 'thermal' and storage_system.heating_coil_capacity is not None:
|
||||||
fuel_breakdown[cte.ELECTRICITY][f'{demand_type}'] += storage_system.heating_coil_energy_consumption[cte.YEAR][0]
|
fuel_breakdown[cte.ELECTRICITY][f'{demand_type}'] += storage_system.heating_coil_energy_consumption[f'{demand_type}'][cte.YEAR][0]
|
||||||
#TODO: When simulation models of all energy system archetypes are created, this part can be removed
|
#TODO: When simulation models of all energy system archetypes are created, this part can be removed
|
||||||
heating_fuels = []
|
heating_fuels = []
|
||||||
dhw_fuels = []
|
dhw_fuels = []
|
||||||
|
@ -913,3 +913,19 @@ class Building(CityObject):
|
||||||
self._fuel_consumption_breakdown = fuel_breakdown
|
self._fuel_consumption_breakdown = fuel_breakdown
|
||||||
return self._fuel_consumption_breakdown
|
return self._fuel_consumption_breakdown
|
||||||
|
|
||||||
|
@property
|
||||||
|
def energy_systems_archetype_cluster_id(self):
|
||||||
|
"""
|
||||||
|
Get energy systems archetype id
|
||||||
|
:return: str
|
||||||
|
"""
|
||||||
|
return self._systems_archetype_cluster_id
|
||||||
|
|
||||||
|
@energy_systems_archetype_cluster_id.setter
|
||||||
|
def energy_systems_archetype_cluster_id(self, value):
|
||||||
|
"""
|
||||||
|
Set energy systems archetype id
|
||||||
|
:param value: str
|
||||||
|
"""
|
||||||
|
self._systems_archetype_cluster_id = value
|
||||||
|
|
||||||
|
|
|
@ -157,6 +157,7 @@ class Surface:
|
||||||
if self._inclination is None:
|
if self._inclination is None:
|
||||||
self._inclination = np.arccos(self.perimeter_polygon.normal[2])
|
self._inclination = np.arccos(self.perimeter_polygon.normal[2])
|
||||||
return self._inclination
|
return self._inclination
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def type(self):
|
def type(self):
|
||||||
"""
|
"""
|
||||||
|
|
|
@ -20,8 +20,8 @@ class ThermalArchetype:
|
||||||
self._indirect_heated_ratio = None
|
self._indirect_heated_ratio = None
|
||||||
self._infiltration_rate_for_ventilation_system_off = None
|
self._infiltration_rate_for_ventilation_system_off = None
|
||||||
self._infiltration_rate_for_ventilation_system_on = None
|
self._infiltration_rate_for_ventilation_system_on = None
|
||||||
self._infiltration_rate_area_for_ventilation_system_off=None
|
self._infiltration_rate_area_for_ventilation_system_off = None
|
||||||
self._infiltration_rate_area_for_ventilation_system_on=None
|
self._infiltration_rate_area_for_ventilation_system_on = None
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def constructions(self) -> [Construction]:
|
def constructions(self) -> [Construction]:
|
||||||
|
@ -141,7 +141,7 @@ class ThermalArchetype:
|
||||||
Get infiltration rate for ventilation system off in l/s/m2
|
Get infiltration rate for ventilation system off in l/s/m2
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._infiltration_rate_for_ventilation_system_off
|
return self._infiltration_rate_area_for_ventilation_system_off
|
||||||
|
|
||||||
@infiltration_rate_area_for_ventilation_system_off.setter
|
@infiltration_rate_area_for_ventilation_system_off.setter
|
||||||
def infiltration_rate_area_for_ventilation_system_off(self, value):
|
def infiltration_rate_area_for_ventilation_system_off(self, value):
|
||||||
|
@ -149,7 +149,7 @@ class ThermalArchetype:
|
||||||
Set infiltration rate for ventilation system off in l/s/m2
|
Set infiltration rate for ventilation system off in l/s/m2
|
||||||
:param value: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._infiltration_rate_for_ventilation_system_off = value
|
self._infiltration_rate_area_for_ventilation_system_off = value
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def infiltration_rate_area_for_ventilation_system_on(self):
|
def infiltration_rate_area_for_ventilation_system_on(self):
|
||||||
|
@ -157,7 +157,7 @@ class ThermalArchetype:
|
||||||
Get infiltration rate for ventilation system on in l/s/m2
|
Get infiltration rate for ventilation system on in l/s/m2
|
||||||
:return: float
|
:return: float
|
||||||
"""
|
"""
|
||||||
return self._infiltration_rate_for_ventilation_system_on
|
return self._infiltration_rate_area_for_ventilation_system_on
|
||||||
|
|
||||||
@infiltration_rate_area_for_ventilation_system_on.setter
|
@infiltration_rate_area_for_ventilation_system_on.setter
|
||||||
def infiltration_rate_area_for_ventilation_system_on(self, value):
|
def infiltration_rate_area_for_ventilation_system_on(self, value):
|
||||||
|
@ -165,4 +165,4 @@ class ThermalArchetype:
|
||||||
Set infiltration rate for ventilation system on in l/s/m2
|
Set infiltration rate for ventilation system on in l/s/m2
|
||||||
:param value: float
|
:param value: float
|
||||||
"""
|
"""
|
||||||
self._infiltration_rate_for_ventilation_system_on = value
|
self._infiltration_rate_area_for_ventilation_system_on = value
|
||||||
|
|
|
@ -11,6 +11,7 @@ from abc import ABC
|
||||||
from typing import Union, List
|
from typing import Union, List
|
||||||
|
|
||||||
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
||||||
|
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
|
||||||
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
||||||
from hub.city_model_structure.energy_systems.electrical_storage_system import ElectricalStorageSystem
|
from hub.city_model_structure.energy_systems.electrical_storage_system import ElectricalStorageSystem
|
||||||
|
|
||||||
|
|
|
@ -24,7 +24,7 @@ class ThermalStorageSystem(EnergyStorageSystem):
|
||||||
self._maximum_operating_temperature = None
|
self._maximum_operating_temperature = None
|
||||||
self._heating_coil_capacity = None
|
self._heating_coil_capacity = None
|
||||||
self._temperature = None
|
self._temperature = None
|
||||||
self._heating_coil_energy_consumption = None
|
self._heating_coil_energy_consumption = {}
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def volume(self):
|
def volume(self):
|
||||||
|
|
|
@ -8,6 +8,8 @@
|
||||||
"extra_loses_due_thermal_bridges": 0.1,
|
"extra_loses_due_thermal_bridges": 0.1,
|
||||||
"infiltration_rate_for_ventilation_system_on": 0,
|
"infiltration_rate_for_ventilation_system_on": 0,
|
||||||
"infiltration_rate_for_ventilation_system_off": 0.9,
|
"infiltration_rate_for_ventilation_system_off": 0.9,
|
||||||
|
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||||
|
"infiltration_rate_area_for_ventilation_system_off": 0.006,
|
||||||
"constructions": {
|
"constructions": {
|
||||||
"OutdoorsWall": {
|
"OutdoorsWall": {
|
||||||
"opaque_surface_name": "residential_1000_1980_BWh",
|
"opaque_surface_name": "residential_1000_1980_BWh",
|
||||||
|
@ -42,6 +44,8 @@
|
||||||
"extra_loses_due_thermal_bridges": 0.1,
|
"extra_loses_due_thermal_bridges": 0.1,
|
||||||
"infiltration_rate_for_ventilation_system_on": 0,
|
"infiltration_rate_for_ventilation_system_on": 0,
|
||||||
"infiltration_rate_for_ventilation_system_off": 0.31,
|
"infiltration_rate_for_ventilation_system_off": 0.31,
|
||||||
|
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||||
|
"infiltration_rate_area_for_ventilation_system_off": 0.002,
|
||||||
"constructions": {
|
"constructions": {
|
||||||
"OutdoorsWall": {
|
"OutdoorsWall": {
|
||||||
"opaque_surface_name": "dormitory_2011_3000_BWh",
|
"opaque_surface_name": "dormitory_2011_3000_BWh",
|
||||||
|
@ -76,6 +80,8 @@
|
||||||
"extra_loses_due_thermal_bridges": 0.09,
|
"extra_loses_due_thermal_bridges": 0.09,
|
||||||
"infiltration_rate_for_ventilation_system_on": 0,
|
"infiltration_rate_for_ventilation_system_on": 0,
|
||||||
"infiltration_rate_for_ventilation_system_off": 0.65,
|
"infiltration_rate_for_ventilation_system_off": 0.65,
|
||||||
|
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||||
|
"infiltration_rate_area_for_ventilation_system_off": 0.004,
|
||||||
"constructions": {
|
"constructions": {
|
||||||
"OutdoorsWall": {
|
"OutdoorsWall": {
|
||||||
"opaque_surface_name": "hotel_employees_1981_2010_BWh",
|
"opaque_surface_name": "hotel_employees_1981_2010_BWh",
|
||||||
|
|
|
@ -21,6 +21,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -44,6 +46,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -67,6 +71,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -89,6 +95,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -111,6 +119,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -133,6 +143,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -155,6 +167,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -177,6 +191,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -199,6 +215,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -221,6 +239,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -243,6 +263,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -265,6 +287,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -287,6 +311,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -309,6 +335,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -331,6 +359,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -353,6 +383,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -375,6 +407,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -397,6 +431,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -419,6 +455,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -441,6 +479,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -463,6 +503,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -485,6 +527,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -507,6 +551,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -529,6 +575,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -551,6 +599,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -573,6 +623,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -595,6 +647,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -617,6 +671,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -639,6 +695,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -661,6 +719,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -683,6 +743,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -705,6 +767,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -727,6 +791,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -749,6 +815,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="35" building_type="residential" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
<archetype id="35" building_type="residential" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -771,6 +839,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="36" building_type="residential" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
<archetype id="36" building_type="residential" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -793,6 +863,8 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
<archetype id="37" building_type="industry" reference_standard="non_standard_dompark" climate_zone="ASHRAE_2004:4A">
|
<archetype id="37" building_type="industry" reference_standard="non_standard_dompark" climate_zone="ASHRAE_2004:4A">
|
||||||
<constructions>
|
<constructions>
|
||||||
|
@ -815,5 +887,7 @@
|
||||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||||
|
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||||
</archetype>
|
</archetype>
|
||||||
</archetypes>
|
</archetypes>
|
||||||
|
|
|
@ -331,7 +331,6 @@ class Idf:
|
||||||
for material in self._idf.idfobjects[self._MATERIAL]:
|
for material in self._idf.idfobjects[self._MATERIAL]:
|
||||||
if material.Name == "DefaultMaterial":
|
if material.Name == "DefaultMaterial":
|
||||||
return
|
return
|
||||||
|
|
||||||
self._idf.set_default_constructions()
|
self._idf.set_default_constructions()
|
||||||
return
|
return
|
||||||
for layer in thermal_boundary.layers:
|
for layer in thermal_boundary.layers:
|
||||||
|
@ -467,7 +466,7 @@ class Idf:
|
||||||
|
|
||||||
def _add_infiltration_surface(self, thermal_zone, zone_name):
|
def _add_infiltration_surface(self, thermal_zone, zone_name):
|
||||||
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
|
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
|
||||||
_infiltration = thermal_zone.infiltration_rate_area_system_off*1
|
_infiltration = thermal_zone.infiltration_rate_area_system_off*cte.INFILTRATION_75PA_TO_4PA
|
||||||
self._idf.newidfobject(self._INFILTRATION,
|
self._idf.newidfobject(self._INFILTRATION,
|
||||||
Name=f'{zone_name}_infiltration',
|
Name=f'{zone_name}_infiltration',
|
||||||
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
|
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
|
||||||
|
|
|
@ -24,6 +24,7 @@ BTU_H_TO_WATTS = 0.29307107
|
||||||
KILO_WATTS_HOUR_TO_JULES = 3600000
|
KILO_WATTS_HOUR_TO_JULES = 3600000
|
||||||
WATTS_HOUR_TO_JULES = 3600
|
WATTS_HOUR_TO_JULES = 3600
|
||||||
GALLONS_TO_QUBIC_METERS = 0.0037854117954011185
|
GALLONS_TO_QUBIC_METERS = 0.0037854117954011185
|
||||||
|
INFILTRATION_75PA_TO_4PA = (4/75)**0.65
|
||||||
|
|
||||||
|
|
||||||
# time
|
# time
|
||||||
|
@ -311,7 +312,8 @@ LATENT = 'Latent'
|
||||||
LITHIUMION = 'Lithium Ion'
|
LITHIUMION = 'Lithium Ion'
|
||||||
NICD = 'NiCd'
|
NICD = 'NiCd'
|
||||||
LEADACID = 'Lead Acid'
|
LEADACID = 'Lead Acid'
|
||||||
|
THERMAL = 'thermal'
|
||||||
|
ELECTRICAL = 'electrical'
|
||||||
# Geometry
|
# Geometry
|
||||||
EPSILON = 0.0000001
|
EPSILON = 0.0000001
|
||||||
|
|
||||||
|
|
|
@ -18,7 +18,7 @@ class MontrealGenerationSystemToHubEnergyGenerationSystem:
|
||||||
'furnace': cte.BASEBOARD,
|
'furnace': cte.BASEBOARD,
|
||||||
'cooler': cte.CHILLER,
|
'cooler': cte.CHILLER,
|
||||||
'electricity generator': cte.ELECTRICITY_GENERATOR,
|
'electricity generator': cte.ELECTRICITY_GENERATOR,
|
||||||
'PV system': cte.PHOTOVOLTAIC,
|
'photovoltaic': cte.PHOTOVOLTAIC,
|
||||||
'heat pump': cte.HEAT_PUMP
|
'heat pump': cte.HEAT_PUMP
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
|
@ -66,6 +66,8 @@ class EilatPhysicsParameters:
|
||||||
thermal_archetype.indirect_heated_ratio = 0
|
thermal_archetype.indirect_heated_ratio = 0
|
||||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||||
|
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||||
|
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||||
effective_thermal_capacity = 0
|
effective_thermal_capacity = 0
|
||||||
_constructions = []
|
_constructions = []
|
||||||
for catalog_construction in catalog_archetype.constructions:
|
for catalog_construction in catalog_archetype.constructions:
|
||||||
|
|
|
@ -81,6 +81,7 @@ class NrcanPhysicsParameters:
|
||||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||||
|
|
||||||
_constructions = []
|
_constructions = []
|
||||||
for catalog_construction in catalog_archetype.constructions:
|
for catalog_construction in catalog_archetype.constructions:
|
||||||
construction = Construction()
|
construction = Construction()
|
||||||
|
|
|
@ -69,6 +69,8 @@ class NrelPhysicsParameters:
|
||||||
thermal_archetype.indirect_heated_ratio = catalog_archetype.indirect_heated_ratio
|
thermal_archetype.indirect_heated_ratio = catalog_archetype.indirect_heated_ratio
|
||||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||||
|
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||||
|
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||||
_constructions = []
|
_constructions = []
|
||||||
for catalog_construction in catalog_archetype.constructions:
|
for catalog_construction in catalog_archetype.constructions:
|
||||||
construction = Construction()
|
construction = Construction()
|
||||||
|
|
|
@ -136,13 +136,13 @@ class MontrealCustomEnergySystemParameters:
|
||||||
_distribution_system.distribution_consumption_variable_flow = \
|
_distribution_system.distribution_consumption_variable_flow = \
|
||||||
archetype_distribution_system.distribution_consumption_variable_flow
|
archetype_distribution_system.distribution_consumption_variable_flow
|
||||||
_distribution_system.heat_losses = archetype_distribution_system.heat_losses
|
_distribution_system.heat_losses = archetype_distribution_system.heat_losses
|
||||||
_emission_system = None
|
_generic_emission_system = None
|
||||||
if archetype_distribution_system.emission_systems is not None:
|
if archetype_distribution_system.emission_systems is not None:
|
||||||
_emission_systems = []
|
_emission_systems = []
|
||||||
for emission_system in archetype_distribution_system.emission_systems:
|
for emission_system in archetype_distribution_system.emission_systems:
|
||||||
_emission_system = EmissionSystem()
|
_generic_emission_system = EmissionSystem()
|
||||||
_emission_system.parasitic_energy_consumption = emission_system.parasitic_energy_consumption
|
_generic_emission_system.parasitic_energy_consumption = emission_system.parasitic_energy_consumption
|
||||||
_emission_systems.append(_emission_system)
|
_emission_systems.append(_generic_emission_system)
|
||||||
_distribution_system.emission_systems = _emission_systems
|
_distribution_system.emission_systems = _emission_systems
|
||||||
_distribution_systems.append(_distribution_system)
|
_distribution_systems.append(_distribution_system)
|
||||||
return _distribution_systems
|
return _distribution_systems
|
||||||
|
|
|
@ -43,6 +43,7 @@ class MontrealFutureEnergySystemParameters:
|
||||||
archetype_name = building.energy_systems_archetype_name
|
archetype_name = building.energy_systems_archetype_name
|
||||||
try:
|
try:
|
||||||
archetype = self._search_archetypes(montreal_custom_catalog, archetype_name)
|
archetype = self._search_archetypes(montreal_custom_catalog, archetype_name)
|
||||||
|
building.energy_systems_archetype_cluster_id = archetype.cluster_id
|
||||||
except KeyError:
|
except KeyError:
|
||||||
logging.error('Building %s has unknown energy system archetype for system name %s', building.name,
|
logging.error('Building %s has unknown energy system archetype for system name %s', building.name,
|
||||||
archetype_name)
|
archetype_name)
|
||||||
|
@ -87,12 +88,12 @@ class MontrealFutureEnergySystemParameters:
|
||||||
archetype_generation_systems = archetype_system.generation_systems
|
archetype_generation_systems = archetype_system.generation_systems
|
||||||
if archetype_generation_systems is not None:
|
if archetype_generation_systems is not None:
|
||||||
for archetype_generation_system in archetype_system.generation_systems:
|
for archetype_generation_system in archetype_system.generation_systems:
|
||||||
if archetype_generation_system.system_type == 'Photovoltaic':
|
if archetype_generation_system.system_type == 'photovoltaic':
|
||||||
_generation_system = PvGenerationSystem()
|
_generation_system = PvGenerationSystem()
|
||||||
_generation_system.name = archetype_generation_system.name
|
_generation_system.name = archetype_generation_system.name
|
||||||
_generation_system.model_name = archetype_generation_system.model_name
|
_generation_system.model_name = archetype_generation_system.model_name
|
||||||
_generation_system.manufacturer = archetype_generation_system.manufacturer
|
_generation_system.manufacturer = archetype_generation_system.manufacturer
|
||||||
_type = 'PV system'
|
_type = archetype_generation_system.system_type
|
||||||
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
||||||
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
||||||
_generation_system.fuel_type = _fuel_type
|
_generation_system.fuel_type = _fuel_type
|
||||||
|
@ -103,15 +104,21 @@ class MontrealFutureEnergySystemParameters:
|
||||||
_generation_system.nominal_radiation = archetype_generation_system.nominal_radiation
|
_generation_system.nominal_radiation = archetype_generation_system.nominal_radiation
|
||||||
_generation_system.standard_test_condition_cell_temperature = archetype_generation_system.standard_test_condition_cell_temperature
|
_generation_system.standard_test_condition_cell_temperature = archetype_generation_system.standard_test_condition_cell_temperature
|
||||||
_generation_system.standard_test_condition_maximum_power = archetype_generation_system.standard_test_condition_maximum_power
|
_generation_system.standard_test_condition_maximum_power = archetype_generation_system.standard_test_condition_maximum_power
|
||||||
|
_generation_system.standard_test_condition_radiation = archetype_generation_system.standard_test_condition_radiation
|
||||||
_generation_system.cell_temperature_coefficient = archetype_generation_system.cell_temperature_coefficient
|
_generation_system.cell_temperature_coefficient = archetype_generation_system.cell_temperature_coefficient
|
||||||
_generation_system.width = archetype_generation_system.width
|
_generation_system.width = archetype_generation_system.width
|
||||||
_generation_system.height = archetype_generation_system.height
|
_generation_system.height = archetype_generation_system.height
|
||||||
_generation_system.tilt_angle = self._city.latitude
|
_generation_system.tilt_angle = self._city.latitude
|
||||||
_generic_storage_system = None
|
_generic_storage_system = None
|
||||||
if archetype_generation_system.energy_storage_systems is not None:
|
if archetype_generation_system.energy_storage_systems is not None:
|
||||||
|
_storage_systems = []
|
||||||
|
for storage_system in archetype_generation_system.energy_storage_systems:
|
||||||
|
if storage_system.type_energy_stored == 'electrical':
|
||||||
_generic_storage_system = ElectricalStorageSystem()
|
_generic_storage_system = ElectricalStorageSystem()
|
||||||
_generic_storage_system.type_energy_stored = 'electrical'
|
_generic_storage_system.type_energy_stored = 'electrical'
|
||||||
_generation_system.energy_storage_systems = [_generic_storage_system]
|
_storage_systems.append(_generic_storage_system)
|
||||||
|
_generation_system.energy_storage_systems = _storage_systems
|
||||||
|
|
||||||
else:
|
else:
|
||||||
_generation_system = NonPvGenerationSystem()
|
_generation_system = NonPvGenerationSystem()
|
||||||
_generation_system.name = archetype_generation_system.name
|
_generation_system.name = archetype_generation_system.name
|
||||||
|
@ -119,7 +126,7 @@ class MontrealFutureEnergySystemParameters:
|
||||||
_generation_system.manufacturer = archetype_generation_system.manufacturer
|
_generation_system.manufacturer = archetype_generation_system.manufacturer
|
||||||
_type = archetype_generation_system.system_type
|
_type = archetype_generation_system.system_type
|
||||||
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
||||||
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
||||||
_generation_system.fuel_type = _fuel_type
|
_generation_system.fuel_type = _fuel_type
|
||||||
_generation_system.nominal_heat_output = archetype_generation_system.nominal_heat_output
|
_generation_system.nominal_heat_output = archetype_generation_system.nominal_heat_output
|
||||||
_generation_system.nominal_cooling_output = archetype_generation_system.nominal_cooling_output
|
_generation_system.nominal_cooling_output = archetype_generation_system.nominal_cooling_output
|
||||||
|
@ -185,13 +192,13 @@ class MontrealFutureEnergySystemParameters:
|
||||||
_distribution_system.distribution_consumption_variable_flow = \
|
_distribution_system.distribution_consumption_variable_flow = \
|
||||||
archetype_distribution_system.distribution_consumption_variable_flow
|
archetype_distribution_system.distribution_consumption_variable_flow
|
||||||
_distribution_system.heat_losses = archetype_distribution_system.heat_losses
|
_distribution_system.heat_losses = archetype_distribution_system.heat_losses
|
||||||
_emission_system = None
|
_generic_emission_system = None
|
||||||
if archetype_distribution_system.emission_systems is not None:
|
if archetype_distribution_system.emission_systems is not None:
|
||||||
_emission_systems = []
|
_emission_systems = []
|
||||||
for emission_system in archetype_distribution_system.emission_systems:
|
for emission_system in archetype_distribution_system.emission_systems:
|
||||||
_emission_system = EmissionSystem()
|
_generic_emission_system = EmissionSystem()
|
||||||
_emission_system.parasitic_energy_consumption = emission_system.parasitic_energy_consumption
|
_generic_emission_system.parasitic_energy_consumption = emission_system.parasitic_energy_consumption
|
||||||
_emission_systems.append(_emission_system)
|
_emission_systems.append(_generic_emission_system)
|
||||||
_distribution_system.emission_systems = _emission_systems
|
_distribution_system.emission_systems = _emission_systems
|
||||||
_distribution_systems.append(_distribution_system)
|
_distribution_systems.append(_distribution_system)
|
||||||
return _distribution_systems
|
return _distribution_systems
|
||||||
|
|
Loading…
Reference in New Issue
Block a user