""" Configuration helper SPDX - License - Identifier: LGPL - 3.0 - or -later Copyright © 2020 Project Author Guille Gutierrez guillermo.gutierrezmorote@concordia.ca """ import configparser from pathlib import Path class ConfigurationHelper: """ Configuration class """ def __init__(self): config_file = Path(Path(__file__).parent.parent / 'config/configuration.ini').resolve() self._config = configparser.ConfigParser() self._config.read(config_file) @property def max_location_distance_for_shared_walls(self) -> float: """ Get configured maximal distance between attributes to consider that they may share walls in meters :return: 5.0 """ return self._config.getfloat('buildings', 'max_location_distance_for_shared_walls') @property def min_coordinate(self) -> float: """ Get configured minimal coordinate value :return: -1.7976931348623157e+308 """ return self._config.getfloat('buildings', 'min_coordinate') @property def max_coordinate(self) -> float: """ Get configured maximal coordinate value :return: 1.7976931348623157e+308 """ return self._config.getfloat('buildings', 'max_coordinate').real @property def comnet_lighting_latent(self) -> float: """ Get configured latent ratio of internal gains do to lighting used for Comnet (ASHRAE) standard :return: 0 """ return self._config.getfloat('buildings', 'comnet_lighting_latent').real @property def comnet_lighting_convective(self) -> float: """ Get configured convective ratio of internal gains do to lighting used for Comnet (ASHRAE) standard :return: 0.5 """ return self._config.getfloat('buildings', 'comnet_lighting_convective').real @property def comnet_lighting_radiant(self) -> float: """ Get configured radiant ratio of internal gains do to lighting used for Comnet (ASHRAE) standard :return: 0.5 """ return self._config.getfloat('buildings', 'comnet_lighting_radiant').real @property def comnet_plugs_latent(self) -> float: """ Get configured latent ratio of internal gains do to electrical appliances used for Comnet (ASHRAE) standard :return: 0 """ return self._config.getfloat('buildings', 'comnet_plugs_latent').real @property def comnet_plugs_convective(self) -> float: """ Get configured convective ratio of internal gains do to electrical appliances used for Comnet (ASHRAE) standard :return: 0.75 """ return self._config.getfloat('buildings', 'comnet_plugs_convective').real @property def comnet_plugs_radiant(self) -> float: """ Get configured radiant ratio of internal gains do to electrical appliances used for Comnet (ASHRAE) standard :return: 0.25 """ return self._config.getfloat('buildings', 'comnet_plugs_radiant').real @property def comnet_occupancy_sensible_convective(self) -> float: """ Get configured convective ratio of the sensible part of internal gains do to occupancy used for Comnet (ASHRAE) standard :return: 0.9 """ return self._config.getfloat('buildings', 'comnet_occupancy_sensible_convective').real @property def comnet_occupancy_sensible_radiant(self) -> float: """ Get configured radiant ratio of the sensible part of internal gains do to occupancy used for Comnet (ASHRAE) standard :return: 0.1 """ return self._config.getfloat('buildings', 'comnet_occupancy_sensible_radiant').real @property def convective_heat_transfer_coefficient_interior(self) -> float: """ Get configured convective heat transfer coefficient for surfaces inside the building :return: 3.5 """ return self._config.getfloat('buildings', 'convective_heat_transfer_coefficient_interior').real @property def convective_heat_transfer_coefficient_exterior(self) -> float: """ Get configured convective heat transfer coefficient for surfaces outside the building :return: 20 """ return self._config.getfloat('buildings', 'convective_heat_transfer_coefficient_exterior').real