204 lines
11 KiB
XML
204 lines
11 KiB
XML
<archetypes>
|
|
<archetype function="residential" municipality="montreal" country="CA" lod="1">
|
|
<currency>CAD</currency>
|
|
<capital_cost>
|
|
<B_shell>
|
|
<B10_superstructure>
|
|
<refurbishment_cost_basement cost_unit="currency/m2"> 0 </refurbishment_cost_basement>
|
|
</B10_superstructure>
|
|
<B20_envelope>
|
|
<B2010_opaque_walls>
|
|
<refurbishment_cost cost_unit="currency/m2"> 304 </refurbishment_cost>
|
|
</B2010_opaque_walls>
|
|
<B2020_transparent>
|
|
<refurbishment_cost cost_unit="currency/m2"> 857.14 </refurbishment_cost>
|
|
</B2020_transparent>
|
|
</B20_envelope>
|
|
<B30_roofing>
|
|
<B3010_opaque_roof>
|
|
<refurbishment_cost cost_unit="currency/m2"> 118 </refurbishment_cost>
|
|
</B3010_opaque_roof>
|
|
</B30_roofing>
|
|
</B_shell>
|
|
<D_services>
|
|
<D30_hvac>
|
|
<D3010_energy_supply>
|
|
<D301010_photovoltaic_system>
|
|
<initial_investment cost_unit="currency/m2"> 800 </initial_investment>
|
|
<reposition cost_unit="currency/m2"> 800 </reposition>
|
|
<lifetime_equipment lifetime="years"> 25 </lifetime_equipment>
|
|
</D301010_photovoltaic_system>
|
|
</D3010_energy_supply>
|
|
<D3020_heat_generating_systems>
|
|
<investment_cost cost_unit="currency/kW"> 622.86 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 622.86 </reposition>
|
|
<lifetime_equipment lifetime="years"> 25 </lifetime_equipment>
|
|
</D3020_heat_generating_systems>
|
|
<D3030_cooling_generation_systems>
|
|
<investment_cost cost_unit="currency/kW"> 622.86 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 622.86 </reposition>
|
|
<lifetime_equipment lifetime="years"> 15 </lifetime_equipment>
|
|
</D3030_cooling_generation_systems>
|
|
<D3040_distribution_systems>
|
|
<investment_cost cost_unit="currency/kW"> 0 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 0 </reposition>
|
|
<lifetime_equipment lifetime="years"> 15 </lifetime_equipment>
|
|
</D3040_distribution_systems>
|
|
<D3080_other_hvac_ahu>
|
|
<investment_cost cost_unit="currency/kW"> 47.62 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 47.62 </reposition>
|
|
<lifetime_equipment lifetime="years"> 15 </lifetime_equipment>
|
|
</D3080_other_hvac_ahu>
|
|
</D30_hvac>
|
|
<D50_electrical>
|
|
<D5020lighting_and_branch_wiring>
|
|
<refurbishment_cost cost_unit="currency/kW"> 139 </refurbishment_cost>
|
|
<reposition cost_unit="currency/kW"> 139 </reposition>
|
|
<lifetime_equipment lifetime="years"> 20 </lifetime_equipment>
|
|
</D5020lighting_and_branch_wiring>
|
|
</D50_electrical>
|
|
</D_services>
|
|
<Z_allowances_overhead_profit>
|
|
<Z10_design_allowance cost_unit="%"> 2.5 </Z10_design_allowance>
|
|
<Z10_overhead_and_profit cost_unit="%"> 14 </Z10_overhead_and_profit>
|
|
</Z_allowances_overhead_profit>
|
|
</capital_cost>
|
|
<operational_cost>
|
|
<fuels>
|
|
<fuel fuel_type="electricity">
|
|
<fixed_monthly cost_unit="currency/month"> 12.27 </fixed_monthly>
|
|
<fixed_power cost_unit="currency/month*kW"> 0 </fixed_power>
|
|
<variable cost_unit="currency/kWh"> 0.075 </variable>
|
|
</fuel>
|
|
<fuel fuel_type="gas">
|
|
<fixed_monthly cost_unit="currency/month"> 17.71 </fixed_monthly>
|
|
<variable cost_unit="currency/kWh"> 0.640 </variable>
|
|
</fuel>
|
|
<fuel fuel_type="diesel">
|
|
<variable cost_unit="currency/l"> 1.2 </variable>
|
|
</fuel>
|
|
<fuel fuel_type="biomass">
|
|
<variable cost_unit="currency/kg"> 0.09 </variable>
|
|
</fuel>
|
|
</fuels>
|
|
<maintenances>
|
|
<maintenance type="heating_equipment" cost_unit="currency/kW">40</maintenance>
|
|
<maintenance type="cooling_equipment" cost_unit="currency/kW">40</maintenance>
|
|
<maintenance type="photovoltaic_system" cost_unit="currency/m2">1</maintenance>
|
|
</maintenances>
|
|
<co2_cost cost_unit="currency/kgCO2"> 30 </co2_cost>
|
|
</operational_cost>
|
|
<end_of_life_cost cost_unit="currency/m2"> 6.3 </end_of_life_cost>
|
|
<incomes>
|
|
<subsidies>
|
|
<subsidy type="construction" cost_unit="%">2</subsidy>
|
|
<subsidy type="hvac" cost_unit="%">1.5</subsidy>
|
|
<subsidy type="photovoltaic" cost_unit="%">3.6</subsidy>
|
|
</subsidies>
|
|
<energy_exports>
|
|
<energy_export type="electricity" cost_unit="currency/kWh">0</energy_export>
|
|
</energy_exports>
|
|
<tax_reduction cost_unit="%">2</tax_reduction>
|
|
</incomes>
|
|
</archetype>
|
|
<archetype function="non-residential" municipality="montreal" country="CA" lod="1">
|
|
<currency>CAD</currency>
|
|
<capital_cost>
|
|
<B_shell>
|
|
<B10_superstructure>
|
|
<refurbishment_cost_basement cost_unit="currency/m2"> 0 </refurbishment_cost_basement>
|
|
</B10_superstructure>
|
|
<B20_envelope>
|
|
<B2010_opaque_walls>
|
|
<refurbishment_cost cost_unit="currency/m2"> 304 </refurbishment_cost>
|
|
</B2010_opaque_walls>
|
|
<B2020_transparent>
|
|
<refurbishment_cost cost_unit="currency/m2"> 857.14 </refurbishment_cost>
|
|
</B2020_transparent>
|
|
</B20_envelope>
|
|
<B30_roofing>
|
|
<B3010_opaque_roof>
|
|
<refurbishment_cost cost_unit="currency/m2"> 118 </refurbishment_cost>
|
|
</B3010_opaque_roof>
|
|
</B30_roofing>
|
|
</B_shell>
|
|
<D_services>
|
|
<D30_hvac>
|
|
<D3010_energy_supply>
|
|
<D301010_photovoltaic_system>
|
|
<initial_investment cost_unit="currency/m2"> 800 </initial_investment>
|
|
<reposition cost_unit="currency/m2"> 800 </reposition>
|
|
<lifetime_equipment lifetime="years"> 25 </lifetime_equipment>
|
|
</D301010_photovoltaic_system>
|
|
</D3010_energy_supply>
|
|
<D3020_heat_generating_systems>
|
|
<investment_cost cost_unit="currency/kW"> 622.86 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 622.86 </reposition>
|
|
<lifetime_equipment lifetime="years"> 25 </lifetime_equipment>
|
|
</D3020_heat_generating_systems>
|
|
<D3030_cooling_generation_systems>
|
|
<investment_cost cost_unit="currency/kW"> 622.86 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 622.86 </reposition>
|
|
<lifetime_equipment lifetime="years"> 15 </lifetime_equipment>
|
|
</D3030_cooling_generation_systems>
|
|
<D3040_distribution_systems>
|
|
<refurbishment_cost cost_unit="currency/m2"> 0 </refurbishment_cost>
|
|
<reposition cost_unit="currency/kW"> 0 </reposition>
|
|
<lifetime_equipment lifetime="years"> 15 </lifetime_equipment>
|
|
</D3040_distribution_systems>
|
|
<D3080_other_hvac_ahu>
|
|
<investment_cost cost_unit="currency/kW"> 47.62 </investment_cost>
|
|
<reposition cost_unit="currency/kW"> 47.62 </reposition>
|
|
<lifetime_equipment lifetime="years"> 15 </lifetime_equipment>
|
|
</D3080_other_hvac_ahu>
|
|
</D30_hvac>
|
|
<D50_electrical>
|
|
<D5020_lighting_and_branch_wiring>
|
|
<refurbishment_cost cost_unit="currency/kW"> 139 </refurbishment_cost>
|
|
<reposition cost_unit="currency/kW"> 139 </reposition>
|
|
<lifetime_equipment lifetime="years"> 20 </lifetime_equipment>
|
|
</D5020_lighting_and_branch_wiring>
|
|
</D50_electrical>
|
|
</D_services>
|
|
<Z_allowances_overhead_profit>
|
|
<Z10_design_allowance cost_unit="%"> 6 </Z10_design_allowance>
|
|
<Z20_overhead_profit cost_unit="%"> 14 </Z20_overhead_profit>
|
|
</Z_allowances_overhead_profit>
|
|
</capital_cost>
|
|
<operational_cost>
|
|
<fuel fuel_type="electricity">
|
|
<fixed_monthly cost_unit="currency/month"> 12.27 </fixed_monthly>
|
|
<fixed_power cost_unit="currency/(month*kW)"> 0 </fixed_power>
|
|
<variable cost_unit="currency/kWh"> 0.075 </variable>
|
|
</fuel>
|
|
<fuel fuel_type="gas">
|
|
<fixed_monthly cost_unit="currency/month"> 17.71 </fixed_monthly>
|
|
<variable cost_unit="currency/m3"> 0.640 </variable>
|
|
</fuel>
|
|
<fuel fuel_type="diesel">
|
|
<variable cost_unit="currency/l"> 1.2 </variable>
|
|
</fuel>
|
|
<fuel fuel_type="biomass">
|
|
<variable cost_unit="currency/kg"> 0.09 </variable>
|
|
</fuel>
|
|
<maintenances>
|
|
<maintenance type="heating_equipment" cost_unit="currency/kW">40</maintenance>
|
|
<maintenance type="cooling_equipment" cost_unit="currency/kW">40</maintenance>
|
|
<maintenance type="photovoltaic_system" cost_unit="currency/m2">1</maintenance>
|
|
</maintenances>
|
|
<CO2_cost cost_unit="currency/kgCO2"> 30 </CO2_cost>
|
|
</operational_cost>
|
|
<end_of_life_cost cost_unit="currency/m2"> 6.3 </end_of_life_cost>
|
|
<incomes>
|
|
<subsidies>
|
|
<subsidy type="construction" cost_unit="%">2</subsidy>
|
|
<subsidy type="hvac" cost_unit="%">1.5</subsidy>
|
|
<subsidy type="photovoltaic" cost_unit="%">3.6</subsidy>
|
|
</subsidies>
|
|
<energy_exports>
|
|
<energy_export type="electricity" cost_unit="currency/kWh">0</energy_export>
|
|
</energy_exports>
|
|
<tax_reduction cost_unit="%">2</tax_reduction>
|
|
</incomes>
|
|
</archetype>
|
|
</archetypes> |