fix: final changes from Oriol were implemented and tested
This commit is contained in:
parent
d77bd7d337
commit
49a531da8f
@ -22,6 +22,7 @@ class EilatCatalog(Catalog):
|
||||
"""
|
||||
Eilat catalog class
|
||||
"""
|
||||
|
||||
def __init__(self, path):
|
||||
_path_archetypes = Path(path / 'eilat_archetypes.json').resolve()
|
||||
_path_constructions = (path / 'eilat_constructions.json').resolve()
|
||||
@ -121,8 +122,14 @@ class EilatCatalog(Catalog):
|
||||
construction_period = archetype['period_of_construction']
|
||||
average_storey_height = archetype['average_storey_height']
|
||||
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
|
||||
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_for_ventilation_system_off = archetype[
|
||||
'infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_for_ventilation_system_on = archetype[
|
||||
'infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_area_for_ventilation_system_off = archetype[
|
||||
'infiltration_rate_area_for_ventilation_system_off']
|
||||
infiltration_rate_area_for_ventilation_system_on = archetype[
|
||||
'infiltration_rate_area_for_ventilation_system_on']
|
||||
|
||||
archetype_constructions = []
|
||||
for archetype_construction in archetype['constructions']:
|
||||
@ -160,7 +167,9 @@ class EilatCatalog(Catalog):
|
||||
extra_loses_due_to_thermal_bridges,
|
||||
None,
|
||||
infiltration_rate_for_ventilation_system_off,
|
||||
infiltration_rate_for_ventilation_system_on))
|
||||
infiltration_rate_for_ventilation_system_on,
|
||||
infiltration_rate_area_for_ventilation_system_off,
|
||||
infiltration_rate_area_for_ventilation_system_on))
|
||||
return _catalog_archetypes
|
||||
|
||||
def names(self, category=None):
|
||||
|
@ -129,6 +129,12 @@ class NrelCatalog(Catalog):
|
||||
infiltration_rate_for_ventilation_system_on = float(
|
||||
archetype['infiltration_rate_for_ventilation_system_on']['#text']
|
||||
) / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_area_for_ventilation_system_off = float(
|
||||
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
|
||||
)
|
||||
infiltration_rate_area_for_ventilation_system_on = float(
|
||||
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
|
||||
)
|
||||
|
||||
archetype_constructions = []
|
||||
for archetype_construction in archetype['constructions']['construction']:
|
||||
@ -162,7 +168,9 @@ class NrelCatalog(Catalog):
|
||||
extra_loses_due_to_thermal_bridges,
|
||||
indirect_heated_ratio,
|
||||
infiltration_rate_for_ventilation_system_off,
|
||||
infiltration_rate_for_ventilation_system_on))
|
||||
infiltration_rate_for_ventilation_system_on,
|
||||
infiltration_rate_area_for_ventilation_system_off,
|
||||
infiltration_rate_area_for_ventilation_system_on))
|
||||
return _catalog_archetypes
|
||||
|
||||
def names(self, category=None):
|
||||
|
@ -132,6 +132,8 @@ class InternalZone:
|
||||
_thermal_boundary = ThermalBoundary(surface, surface.solid_polygon.area, windows_areas)
|
||||
surface.associated_thermal_boundaries = [_thermal_boundary]
|
||||
_thermal_boundaries.append(_thermal_boundary)
|
||||
if self.thermal_archetype is None:
|
||||
return None # there are no archetype
|
||||
_number_of_storeys = int(self.volume / self.area / self.thermal_archetype.average_storey_height)
|
||||
_thermal_zone = ThermalZone(_thermal_boundaries, self, self.volume, self.area, _number_of_storeys)
|
||||
for thermal_boundary in _thermal_zone.thermal_boundaries:
|
||||
|
@ -18,6 +18,7 @@ from hub.city_model_structure.attributes.point import Point
|
||||
from hub.city_model_structure.greenery.vegetation import Vegetation
|
||||
from hub.city_model_structure.building_demand.thermal_boundary import ThermalBoundary
|
||||
import hub.helpers.constants as cte
|
||||
from hub.helpers.configuration_helper import ConfigurationHelper
|
||||
|
||||
|
||||
class Surface:
|
||||
@ -41,7 +42,7 @@ class Surface:
|
||||
self._short_wave_reflectance = None
|
||||
self._long_wave_emittance = None
|
||||
self._inverse = None
|
||||
self._associated_thermal_boundaries = []
|
||||
self._associated_thermal_boundaries = None
|
||||
self._vegetation = None
|
||||
self._percentage_shared = None
|
||||
self._solar_collectors_area_reduction_factor = None
|
||||
@ -167,10 +168,10 @@ class Surface:
|
||||
"""
|
||||
if self._type is None:
|
||||
inclination_cos = math.cos(self.inclination)
|
||||
# 170 degrees
|
||||
# 170 degrees
|
||||
if inclination_cos <= -0.98:
|
||||
self._type = 'Ground'
|
||||
# between 80 and 100 degrees
|
||||
# between 80 and 100 degrees
|
||||
elif abs(inclination_cos) <= 0.17:
|
||||
self._type = 'Wall'
|
||||
else:
|
||||
@ -365,12 +366,12 @@ class Surface:
|
||||
_protected_building_restriction = 1
|
||||
# 10 degrees range
|
||||
if abs(math.sin(self.inclination)) < 0.17:
|
||||
# horizontal
|
||||
# horizontal
|
||||
_construction_restriction = 0.8
|
||||
_separation_of_panels = 0.46
|
||||
_shadow_between_panels = 0.7
|
||||
else:
|
||||
# tilted
|
||||
# tilted
|
||||
_construction_restriction = 0.9
|
||||
_separation_of_panels = 0.9
|
||||
_shadow_between_panels = 1
|
||||
@ -417,4 +418,4 @@ class Surface:
|
||||
Set installed solar collector area in m2
|
||||
:return: dict
|
||||
"""
|
||||
self._installed_solar_collector_area = value
|
||||
self._installed_solar_collector_area = value
|
@ -141,7 +141,7 @@ class ThermalArchetype:
|
||||
Get infiltration rate for ventilation system off in l/s/m2
|
||||
:return: float
|
||||
"""
|
||||
return self._infiltration_rate_for_ventilation_system_off
|
||||
return self._infiltration_rate_area_for_ventilation_system_off
|
||||
|
||||
@infiltration_rate_area_for_ventilation_system_off.setter
|
||||
def infiltration_rate_area_for_ventilation_system_off(self, value):
|
||||
@ -149,7 +149,7 @@ class ThermalArchetype:
|
||||
Set infiltration rate for ventilation system off in l/s/m2
|
||||
:param value: float
|
||||
"""
|
||||
self._infiltration_rate_for_ventilation_system_off = value
|
||||
self._infiltration_rate_area_for_ventilation_system_off = value
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_for_ventilation_system_on(self):
|
||||
@ -157,7 +157,7 @@ class ThermalArchetype:
|
||||
Get infiltration rate for ventilation system on in l/s/m2
|
||||
:return: float
|
||||
"""
|
||||
return self._infiltration_rate_for_ventilation_system_on
|
||||
return self._infiltration_rate_area_for_ventilation_system_on
|
||||
|
||||
@infiltration_rate_area_for_ventilation_system_on.setter
|
||||
def infiltration_rate_area_for_ventilation_system_on(self, value):
|
||||
@ -165,5 +165,4 @@ class ThermalArchetype:
|
||||
Set infiltration rate for ventilation system on in l/s/m2
|
||||
:param value: float
|
||||
"""
|
||||
self._infiltration_rate_for_ventilation_system_on = value
|
||||
|
||||
self._infiltration_rate_area_for_ventilation_system_on = value
|
||||
|
@ -8,6 +8,8 @@
|
||||
"extra_loses_due_thermal_bridges": 0.1,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.9,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.006,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "residential_1000_1980_BWh",
|
||||
@ -42,6 +44,8 @@
|
||||
"extra_loses_due_thermal_bridges": 0.1,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.31,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.002,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "dormitory_2011_3000_BWh",
|
||||
@ -76,6 +80,8 @@
|
||||
"extra_loses_due_thermal_bridges": 0.09,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.65,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.004,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "hotel_employees_1981_2010_BWh",
|
||||
|
@ -21,6 +21,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -44,6 +46,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -67,6 +71,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -89,6 +95,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -111,6 +119,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -133,6 +143,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -155,6 +167,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -177,6 +191,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -199,6 +215,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -221,6 +239,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -243,6 +263,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -265,6 +287,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -287,6 +311,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -309,6 +335,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -331,6 +359,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -353,6 +383,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -375,6 +407,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -397,6 +431,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -419,6 +455,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -441,6 +479,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -463,6 +503,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -485,6 +527,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -507,6 +551,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -529,6 +575,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -551,6 +599,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -573,6 +623,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -595,6 +647,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -617,6 +671,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -639,6 +695,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -661,6 +719,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -683,6 +743,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -705,6 +767,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -727,6 +791,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -749,6 +815,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="35" building_type="residential" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -771,6 +839,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="36" building_type="residential" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -793,6 +863,8 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="37" building_type="industry" reference_standard="non_standard_dompark" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
@ -815,5 +887,7 @@
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
</archetypes>
|
||||
|
@ -331,7 +331,6 @@ class Idf:
|
||||
for material in self._idf.idfobjects[self._MATERIAL]:
|
||||
if material.Name == "DefaultMaterial":
|
||||
return
|
||||
|
||||
self._idf.set_default_constructions()
|
||||
return
|
||||
for layer in thermal_boundary.layers:
|
||||
@ -467,7 +466,7 @@ class Idf:
|
||||
|
||||
def _add_infiltration_surface(self, thermal_zone, zone_name):
|
||||
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
|
||||
_infiltration = thermal_zone.infiltration_rate_area_system_off*1
|
||||
_infiltration = thermal_zone.infiltration_rate_area_system_off*cte.INFILTRATION_75PA_TO_4PA
|
||||
self._idf.newidfobject(self._INFILTRATION,
|
||||
Name=f'{zone_name}_infiltration',
|
||||
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
|
||||
|
@ -1,4 +1,4 @@
|
||||
!IDD_Version 23.2.0
|
||||
!IDD_Version 24.1.0
|
||||
!IDD_BUILD 7636e6b3e9
|
||||
! ***************************************************************************
|
||||
! This file is the Input Data Dictionary (IDD) for EnergyPlus.
|
||||
@ -30002,10 +30002,10 @@ People,
|
||||
A7 , \field Mean Radiant Temperature Calculation Type
|
||||
\note optional (only required for thermal comfort runs)
|
||||
\type choice
|
||||
\key ZoneAveraged
|
||||
\key EnclosureAveraged
|
||||
\key SurfaceWeighted
|
||||
\key AngleFactor
|
||||
\default ZoneAveraged
|
||||
\default EnclosureAveraged
|
||||
A8 , \field Surface Name/Angle Factor List Name
|
||||
\type object-list
|
||||
\object-list AllHeatTranAngFacNames
|
||||
|
@ -13,7 +13,7 @@
|
||||
! HVAC: None.
|
||||
!
|
||||
|
||||
Version,23.2;
|
||||
Version,24.1;
|
||||
|
||||
Timestep,4;
|
||||
|
||||
@ -154,4 +154,4 @@
|
||||
Output:Meter,InteriorLights:Electricity,hourly;
|
||||
|
||||
OutputControl:IlluminanceMap:Style,
|
||||
Comma; !- Column separator
|
||||
Comma; !- Column separator
|
||||
|
@ -20,9 +20,10 @@ class EnergyBuildingsExportsFactory:
|
||||
"""
|
||||
Energy Buildings exports factory class
|
||||
"""
|
||||
def __init__(self, handler, city, path, custom_insel_block='d18599', target_buildings=None):
|
||||
def __init__(self, handler, city, path, custom_insel_block='d18599', target_buildings=None, weather_file=None):
|
||||
self._city = city
|
||||
self._export_type = '_' + handler.lower()
|
||||
self._weather_file = weather_file
|
||||
validate_import_export_type(EnergyBuildingsExportsFactory, handler)
|
||||
if isinstance(path, str):
|
||||
path = Path(path)
|
||||
@ -53,12 +54,13 @@ class EnergyBuildingsExportsFactory:
|
||||
"""
|
||||
idf_data_path = (Path(__file__).parent / './building_energy/idf_files/').resolve()
|
||||
url = wh().epw_file(self._city.region_code)
|
||||
weather_path = (Path(__file__).parent.parent / f'data/weather/epw/{url.rsplit("/", 1)[1]}').resolve()
|
||||
if not weather_path.exists():
|
||||
with open(weather_path, 'wb') as epw_file:
|
||||
if self._weather_file is None:
|
||||
self._weather_file = (Path(__file__).parent.parent / f'data/weather/epw/{url.rsplit("/", 1)[1]}').resolve()
|
||||
if not self._weather_file.exists():
|
||||
with open(self._weather_file, 'wb') as epw_file:
|
||||
epw_file.write(requests.get(url, allow_redirects=True).content)
|
||||
return Idf(self._city, self._path, (idf_data_path / 'Minimal.idf'), (idf_data_path / 'Energy+.idd'), weather_path,
|
||||
target_buildings=self._target_buildings)
|
||||
return Idf(self._city, self._path, (idf_data_path / 'Minimal.idf'), (idf_data_path / 'Energy+.idd'),
|
||||
self._weather_file, target_buildings=self._target_buildings)
|
||||
|
||||
@property
|
||||
def _insel_monthly_energy_balance(self):
|
||||
|
@ -24,6 +24,8 @@ BTU_H_TO_WATTS = 0.29307107
|
||||
KILO_WATTS_HOUR_TO_JULES = 3600000
|
||||
WATTS_HOUR_TO_JULES = 3600
|
||||
GALLONS_TO_QUBIC_METERS = 0.0037854117954011185
|
||||
INFILTRATION_75PA_TO_4PA = (4/75)**0.65
|
||||
|
||||
|
||||
# time
|
||||
SECOND = 'second'
|
||||
|
@ -66,6 +66,8 @@ class EilatPhysicsParameters:
|
||||
thermal_archetype.indirect_heated_ratio = 0
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||
effective_thermal_capacity = 0
|
||||
_constructions = []
|
||||
for catalog_construction in catalog_archetype.constructions:
|
||||
|
@ -69,6 +69,8 @@ class NrelPhysicsParameters:
|
||||
thermal_archetype.indirect_heated_ratio = catalog_archetype.indirect_heated_ratio
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||
_constructions = []
|
||||
for catalog_construction in catalog_archetype.constructions:
|
||||
construction = Construction()
|
||||
|
@ -136,3 +136,7 @@ class City(Repository):
|
||||
except SQLAlchemyError as err:
|
||||
logging.error('Error while fetching city by name %s', err)
|
||||
raise SQLAlchemyError from err
|
||||
|
||||
def get_by_id(self, city_id) -> Model:
|
||||
with Session(self.engine) as session:
|
||||
return session.execute(select(Model).where(Model.id == city_id)).first()[0]
|
61
main.py
61
main.py
@ -1,61 +0,0 @@
|
||||
from pathlib import Path
|
||||
|
||||
import pandas as pd
|
||||
from building_modelling.geojson_creator import process_geojson
|
||||
from building_modelling.ep_run_enrich import energy_plus_workflow
|
||||
from hub.imports.geometry_factory import GeometryFactory
|
||||
from hub.helpers.dictionaries import Dictionaries
|
||||
from hub.imports.construction_factory import ConstructionFactory
|
||||
from hub.imports.usage_factory import UsageFactory
|
||||
from hub.imports.weather_factory import WeatherFactory
|
||||
import hub.helpers.constants as cte
|
||||
|
||||
# Specify the GeoJSON file path
|
||||
input_files_path = (Path(__file__).parent / 'input_files')
|
||||
input_files_path.mkdir(parents=True, exist_ok=True)
|
||||
geojson_file = process_geojson(x=-73.5681295982132, y=45.49218262677643, diff=0.00006)
|
||||
geojson_file_path = input_files_path / 'output_buildings_expanded.geojson'
|
||||
output_path = (Path(__file__).parent / 'out_files').resolve()
|
||||
output_path.mkdir(parents=True, exist_ok=True)
|
||||
energy_plus_output_path = output_path / 'energy_plus_outputs'
|
||||
energy_plus_output_path.mkdir(parents=True, exist_ok=True)
|
||||
simulation_results_path = (Path(__file__).parent / 'out_files' / 'simulation_results').resolve()
|
||||
simulation_results_path.mkdir(parents=True, exist_ok=True)
|
||||
sra_output_path = output_path / 'sra_outputs'
|
||||
sra_output_path.mkdir(parents=True, exist_ok=True)
|
||||
cost_analysis_output_path = output_path / 'cost_analysis'
|
||||
cost_analysis_output_path.mkdir(parents=True, exist_ok=True)
|
||||
city = GeometryFactory(file_type='geojson',
|
||||
path=geojson_file_path,
|
||||
height_field='height',
|
||||
year_of_construction_field='year_of_construction',
|
||||
function_field='function',
|
||||
function_to_hub=Dictionaries().montreal_function_to_hub_function).city
|
||||
ConstructionFactory('nrcan', city).enrich()
|
||||
UsageFactory('nrcan', city).enrich()
|
||||
WeatherFactory('epw', city).enrich()
|
||||
energy_plus_workflow(city, energy_plus_output_path)
|
||||
building_name = []
|
||||
building_function = []
|
||||
building_year_of_construction = []
|
||||
total_floor_area = []
|
||||
building_heui = []
|
||||
building_ceui = []
|
||||
for building in city.buildings:
|
||||
building_name.append(building.name)
|
||||
building_function.append(building.function)
|
||||
building_year_of_construction.append(building.year_of_construction)
|
||||
total_floor_area.append(building.thermal_zones_from_internal_zones[0].total_floor_area)
|
||||
building_heui.append(building.heating_demand[cte.YEAR][0] / (
|
||||
building.thermal_zones_from_internal_zones[0].total_floor_area * 3.6e6))
|
||||
building_ceui.append(building.cooling_demand[cte.YEAR][0] / (
|
||||
building.thermal_zones_from_internal_zones[0].total_floor_area * 3.6e6))
|
||||
|
||||
df = pd.DataFrame()
|
||||
df['building name'] = building_name
|
||||
df['function'] = building_function
|
||||
df['yoc'] = building_year_of_construction
|
||||
df['floor_area'] = total_floor_area
|
||||
df['heating_eui'] = building_heui
|
||||
df['cooling_eui'] = building_ceui
|
||||
df.to_csv('results.csv')
|
@ -1,20 +0,0 @@
|
||||
,building name,function,yoc,floor_area,heating_eui,cooling_eui
|
||||
0,173347,residential,1986,265.38375176489353,267.0533083996842,18.007308537312785
|
||||
1,173348,residential,1986,283.668703481555,522.850852783527,20.576579713797777
|
||||
2,173403,residential,1985,11447.230666354299,228.49446179883506,12.684394922648671
|
||||
3,174898,residential,1986,283.6906412792159,522.7696663647462,19.57503262214429
|
||||
4,175785,residential,1986,467.7235050201416,516.4055045521648,21.088254314769788
|
||||
5,175910,residential,1986,261.0009156614542,527.5080465374183,25.742695259498305
|
||||
6,176056,residential,1986,182.04670348763466,349.0021295379444,16.753929193049903
|
||||
7,176261,residential,1986,277.90742287479225,583.4254987281645,26.256967472981707
|
||||
8,176293,residential,1986,369.68735361099243,257.4909312314216,14.023930562649928
|
||||
9,176296,residential,1986,290.90516459941864,575.7189866853944,19.385255082748102
|
||||
10,176298,residential,1986,369.51916921138763,257.2805985434431,14.098189573739344
|
||||
11,176918,residential,1987,2326.6517127379775,345.8090447174934,16.443395331027673
|
||||
12,178164,residential,1986,264.07378363609314,268.730268398251,17.960546856543576
|
||||
13,179679,residential,1986,260.14088670909405,271.81072456915604,18.017496250196757
|
||||
14,179789,residential,1986,181.17727002501488,349.001383425343,16.54743635457496
|
||||
15,181310,residential,1986,181.64067029953003,349.52817271006825,16.32917192857884
|
||||
16,182393,residential,1986,199.37044820690062,684.773963332913,21.540957535632746
|
||||
17,182442,residential,1986,277.0023966698591,312.7559318665529,15.48912001605364
|
||||
18,182546,residential,1986,182.38363614678383,687.7449588121772,28.929786166435022
|
|
Loading…
Reference in New Issue
Block a user