added system for refurbishment to catalog

This commit is contained in:
Pilar Monsalvete 2023-06-07 09:48:45 -04:00
parent bd23185ca3
commit 502e1e8279
3 changed files with 43 additions and 7 deletions

View File

@ -30,6 +30,12 @@
<electrical_efficiency>0.22</electrical_efficiency>
<storage>true</storage>
</equipment>
<equipment id="7" type="heat pump" fuel_type="electricity">
<name>Heat Pump</name>
<heating_efficiency>2.79</heating_efficiency>
<cooling_efficiency>3.23</cooling_efficiency>
<storage>false</storage>
</equipment>
</generation_equipments>
<distribution_equipments>
<equipment id="1" type="Water distribution heating">
@ -282,6 +288,29 @@
<dissipation_id>3</dissipation_id>
</equipments>
</system>
<system id="17">
<name>Multi-zone built-up system with heat pump for heat</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>7</generation_id>
<distribution_id>1</distribution_id>
<dissipation_id>2</dissipation_id>
</equipments>
</system>
<system id="18">
<name>Multi-zone built-up system with heat pump for cooling</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>7</generation_id>
<distribution_id>2</distribution_id>
<dissipation_id>2</dissipation_id>
</equipments>
</system>
</systems>
<system_clusters>
<system_cluster name="system 1 gas">
@ -399,5 +428,12 @@
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 7 electricity pv">
<systems>
<system_id>17</system_id>
<system_id>18</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
</system_clusters>
</catalog>

View File

@ -581,19 +581,19 @@ class Idf:
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Zone Ideal Loads Supply Air Total Heating Energy",
Reporting_Frequency="Monthly",
Reporting_Frequency="Hourly",
)
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Zone Ideal Loads Supply Air Total Cooling Energy",
Reporting_Frequency="Monthly",
Reporting_Frequency="Hourly",
)
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Water Use Equipment Heating Rate",
Reporting_Frequency="Monthly",
Reporting_Frequency="Hourly",
)
# post-process to erase windows associated to adiabatic walls

View File

@ -148,10 +148,10 @@
OutputControl:Table:Style, CommaAndHTML,JtoKWH;
Output:Meter,DISTRICTHEATING:Facility,monthly;
Output:Meter,DISTRICTCOOLING:Facility,monthly;
Output:Meter,InteriorEquipment:Electricity,monthly;
Output:Meter,InteriorLights:Electricity,monthly;
Output:Meter,DISTRICTHEATING:Facility,hourly;
Output:Meter,DISTRICTCOOLING:Facility,hourly;
Output:Meter,InteriorEquipment:Electricity,hourly;
Output:Meter,InteriorLights:Electricity,hourly;
OutputControl:IlluminanceMap:Style,
Comma; !- Column separator