fixed the tcold bug in weather importer
This commit is contained in:
parent
81a59d4246
commit
559e56dd71
|
@ -131,4 +131,26 @@ class EpwWeatherParameters:
|
|||
if cte.YEAR not in building.cold_water_temperature:
|
||||
building.cold_water_temperature[cte.YEAR] = wh().get_yearly_mean_values(
|
||||
building.cold_water_temperature[cte.HOUR][['epw']])
|
||||
|
||||
# If the usage has already being imported, the domestic hot water missing values must be calculated here that
|
||||
# the cold water temperature is finally known
|
||||
cold_temperature = building.cold_water_temperature[cte.YEAR]['epw']
|
||||
for internal_zone in building.internal_zones:
|
||||
if internal_zone.usages is not None:
|
||||
for usage in internal_zone.usages:
|
||||
if usage.domestic_hot_water.peak_flow is None:
|
||||
if usage.domestic_hot_water.density is None:
|
||||
continue
|
||||
peak_flow = 0
|
||||
if (usage.domestic_hot_water.service_temperature - cold_temperature) > 0:
|
||||
peak_flow = usage.domestic_hot_water.density / cte.WATER_DENSITY / cte.WATER_HEAT_CAPACITY \
|
||||
/ (usage.domestic_hot_water.service_temperature - cold_temperature)
|
||||
usage.domestic_hot_water.peak_flow = peak_flow
|
||||
if usage.domestic_hot_water.density is None:
|
||||
if usage.domestic_hot_water.peak_flow is None:
|
||||
continue
|
||||
density = usage.domestic_hot_water.peak_flow * cte.WATER_DENSITY * cte.WATER_HEAT_CAPACITY \
|
||||
* (usage.domestic_hot_water.service_temperature - cold_temperature)
|
||||
usage.domestic_hot_water.density = density
|
||||
|
||||
self._city.level_of_detail.weather = 2
|
||||
|
|