Changed idf to start producing detailed systems
This commit is contained in:
parent
5fa55ea79f
commit
a3c5219ccd
@ -54,6 +54,7 @@ class Idf:
|
||||
_SIZING_PERIODS = 'SIZINGPERIOD:DESIGNDAY'
|
||||
_LOCATION = 'SITE:LOCATION'
|
||||
_SIMPLE = 'Simple'
|
||||
_EQUIPMENT_CONNECTIONS = 'ZONEHVAC:EQUIPMENTCONNECTIONS'
|
||||
|
||||
idf_surfaces = {
|
||||
cte.WALL: 'wall',
|
||||
@ -385,12 +386,13 @@ class Idf:
|
||||
if air_system.Zone_Name == zone_name:
|
||||
return
|
||||
thermostat = self._add_thermostat(thermal_zone)
|
||||
self._idf.newidfobject(self._IDEAL_LOAD_AIR_SYSTEM,
|
||||
self._idf.newidfobject(self._EQUIPMENT_CONNECTIONS,
|
||||
Zone_Name=zone_name,
|
||||
System_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
||||
Heating_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
||||
Cooling_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
||||
Template_Thermostat_Name=thermostat.Name)
|
||||
Zone_Conditioning_Equipment_List_Name=f'{thermal_zone.usage_name} Equipment List',
|
||||
Zone_Air_Inlet_Node_or_NodeList_Name=f'{thermal_zone.usage_name} Inlet Node List',
|
||||
Zone_Air_Node_Name=f'Node 1',
|
||||
Zone_Return_Air_Node_or_NodeList_Name=f'{thermal_zone.usage_name} Return Node List')
|
||||
|
||||
|
||||
def _add_occupancy(self, thermal_zone, zone_name):
|
||||
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area
|
||||
|
@ -1,4 +1,4 @@
|
||||
"""
|
||||
"""
|
||||
TestExports test and validate the city export formats
|
||||
SPDX - License - Identifier: LGPL - 3.0 - or -later
|
||||
Copyright © 2022 Concordia CERC group
|
||||
|
142
texttest
Normal file
142
texttest
Normal file
@ -0,0 +1,142 @@
|
||||
ZoneControl:Thermostat,
|
||||
Room_180_7ad8616b Thermostat, !- Name
|
||||
Room_180_7ad8616b, !- Zone or ZoneList Name
|
||||
Room_180_7ad8616b Thermostat Schedule, !- Control Type Schedule Name
|
||||
ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
|
||||
LargeOffice Building_Setpoint 26, !- Control 1 Name
|
||||
, !- Control 2 Object Type
|
||||
, !- Control 2 Name
|
||||
, !- Control 3 Object Type
|
||||
, !- Control 3 Name
|
||||
, !- Control 4 Object Type
|
||||
, !- Control 4 Name
|
||||
0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
|
||||
|
||||
Schedule:Compact,
|
||||
Room_180_7ad8616b Thermostat Schedule, !- Name
|
||||
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Schedule Type Limits Name
|
||||
Through: 12/31, !- Field 1
|
||||
For: AllDays, !- Field 2
|
||||
Until: 24:00, !- Field 3
|
||||
4; !- Field 4
|
||||
|
||||
ScheduleTypeLimits,
|
||||
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Name
|
||||
0, !- Lower Limit Value {BasedOnField A3}
|
||||
4, !- Upper Limit Value {BasedOnField A3}
|
||||
DISCRETE; !- Numeric Type
|
||||
|
||||
ThermostatSetpoint:DualSetpoint,
|
||||
LargeOffice Building_Setpoint 26, !- Name
|
||||
LargeOffice Building_Setpoint_HtgSetp Schedule, !- Heating Setpoint Temperature Schedule Name
|
||||
LargeOffice Building_Setpoint_ClgSetp Schedule; !- Cooling Setpoint Temperature Schedule Name
|
||||
|
||||
ZoneHVAC:EquipmentConnections,
|
||||
Room_180_7ad8616b, !- Zone Name
|
||||
Room_180_7ad8616b Equipment List, !- Zone Conditioning Equipment List Name
|
||||
Room_180_7ad8616b Inlet Node List, !- Zone Air Inlet Node or NodeList Name
|
||||
, !- Zone Air Exhaust Node or NodeList Name
|
||||
Node 27, !- Zone Air Node Name
|
||||
Room_180_7ad8616b Return Node List; !- Zone Return Air Node or NodeList Name
|
||||
|
||||
NodeList,
|
||||
Room_180_7ad8616b Inlet Node List, !- Name
|
||||
Node 305; !- Node Name 1
|
||||
|
||||
NodeList,
|
||||
Room_180_7ad8616b Return Node List, !- Name
|
||||
Node 308; !- Node Name 1
|
||||
|
||||
ZoneHVAC:Baseboard:Convective:Electric,
|
||||
Elec Baseboard 1, !- Name
|
||||
Always On Discrete hvac_library, !- Availability Schedule Name
|
||||
, !- Heating Design Capacity Method
|
||||
Autosize, !- Heating Design Capacity {W}
|
||||
, !- Heating Design Capacity Per Floor Area {W/m2}
|
||||
, !- Fraction of Autosized Heating Design Capacity
|
||||
1; !- Efficiency
|
||||
|
||||
AirTerminal:SingleDuct:ConstantVolume:NoReheat,
|
||||
Diffuser 21, !- Name
|
||||
Always On Discrete hvac_library, !- Availability Schedule Name
|
||||
Node 307, !- Air Inlet Node Name
|
||||
Node 305, !- Air Outlet Node Name
|
||||
AutoSize; !- Maximum Air Flow Rate {m3/s}
|
||||
|
||||
ZoneHVAC:AirDistributionUnit,
|
||||
ADU Diffuser 21, !- Name
|
||||
Node 305, !- Air Distribution Unit Outlet Node Name
|
||||
AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type
|
||||
Diffuser 21; !- Air Terminal Name
|
||||
|
||||
ZoneHVAC:EquipmentList,
|
||||
Room_180_7ad8616b Equipment List, !- Name
|
||||
SequentialLoad, !- Load Distribution Scheme
|
||||
ZoneHVAC:Baseboard:Convective:Electric, !- Zone Equipment Object Type 1
|
||||
Elec Baseboard 1, !- Zone Equipment Name 1
|
||||
1, !- Zone Equipment Cooling Sequence 1
|
||||
1, !- Zone Equipment Heating or No-Load Sequence 1
|
||||
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 1
|
||||
, !- Zone Equipment Sequential Heating Fraction Schedule Name 1
|
||||
ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type 2
|
||||
ADU Diffuser 21, !- Zone Equipment Name 2
|
||||
2, !- Zone Equipment Cooling Sequence 2
|
||||
2, !- Zone Equipment Heating or No-Load Sequence 2
|
||||
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 2
|
||||
; !- Zone Equipment Sequential Heating Fraction Schedule Name 2
|
||||
|
||||
Sizing:Zone,
|
||||
Room_180_7ad8616b, !- Zone or ZoneList Name
|
||||
SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
|
||||
14, !- Zone Cooling Design Supply Air Temperature {C}
|
||||
11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
|
||||
SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
|
||||
40, !- Zone Heating Design Supply Air Temperature {C}
|
||||
11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
|
||||
0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||
0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||
Room_180_7ad8616b DSOA Space List, !- Design Specification Outdoor Air Object Name
|
||||
, !- Zone Heating Sizing Factor
|
||||
, !- Zone Cooling Sizing Factor
|
||||
DesignDay, !- Cooling Design Air Flow Method
|
||||
0, !- Cooling Design Air Flow Rate {m3/s}
|
||||
0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
|
||||
0, !- Cooling Minimum Air Flow {m3/s}
|
||||
0, !- Cooling Minimum Air Flow Fraction
|
||||
DesignDay, !- Heating Design Air Flow Method
|
||||
0, !- Heating Design Air Flow Rate {m3/s}
|
||||
0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
|
||||
0.1415762, !- Heating Maximum Air Flow {m3/s}
|
||||
0.3, !- Heating Maximum Air Flow Fraction
|
||||
, !- Design Specification Zone Air Distribution Object Name
|
||||
No, !- Account for Dedicated Outdoor Air System
|
||||
, !- Dedicated Outdoor Air System Control Strategy
|
||||
, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C}
|
||||
, !- Dedicated Outdoor Air High Setpoint Temperature for Design {C}
|
||||
Sensible Load Only No Latent Load, !- Zone Load Sizing Method
|
||||
HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method
|
||||
, !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||
0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
|
||||
HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method
|
||||
, !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
||||
0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
|
||||
|
||||
DesignSpecification:OutdoorAir:SpaceList,
|
||||
Room_180_7ad8616b DSOA Space List, !- Name
|
||||
Room_180_7ad8616b_Space, !- Space Name 1
|
||||
MidriseApartment Apartment Ventilation; !- Space Design Specification Outdoor Air Object Name 1
|
||||
|
||||
Zone,
|
||||
Room_181_3a411b5d, !- Name
|
||||
, !- Direction of Relative North {deg}
|
||||
0, !- X Origin {m}
|
||||
0, !- Y Origin {m}
|
||||
0, !- Z Origin {m}
|
||||
, !- Type
|
||||
1, !- Multiplier
|
||||
4, !- Ceiling Height {m}
|
||||
291.62935408288, !- Volume {m3}
|
||||
, !- Floor Area {m2}
|
||||
, !- Zone Inside Convection Algorithm
|
||||
, !- Zone Outside Convection Algorithm
|
||||
Yes; !- Part of Total Floor Area
|