diff --git a/hub/data/energy_systems/montreal_custom_systems.xml b/hub/data/energy_systems/montreal_custom_systems.xml index 97813ec6..b49bbc62 100644 --- a/hub/data/energy_systems/montreal_custom_systems.xml +++ b/hub/data/energy_systems/montreal_custom_systems.xml @@ -26,34 +26,72 @@ - - ??? + + Water distribution heating 10 - 1000000000 - 1000000000 + 4 + 1 - - ??? - 25 - 1000000000 - 1000000000 + + Water distribution cooling + 10 + 4 + 1 - - ??? + + Central air distribution heating + 10 + 13 + 13 + + + Central air distribution cooling + 10 + 13 + 13 + + + Local air distribution heating + 10 + 8 + 8 + + + Local air distribution cooling + 10 + 8 + 8 + + + Refrigerant distribution + 1 + 1 + 2 + + + No distribution 0 - 1000000000 - 1000000000 + 0 + 0 Baseboards - ??? + 0 + + + fan-coils + 2 + + + inductors + 0 - Fuel-fired water boiler with baseboards + Unitary air conditioner with baseboard heater fuel fired boiler heating domestic_hot_water @@ -61,12 +99,25 @@ 1 1 - ??? + 1 false - - Electrical resistance water boiler + + 4 pipe fan coils with fuel fired boiler + + heating + domestic_hot_water + + + 1 + 1 + 2 + + false + + + 4 pipe fan coils with electrical resistance water boiler heating domestic_hot_water @@ -74,38 +125,38 @@ 2 1 - ??? + 2 true - - Fuel-fired furnace and fuel boiler for acs + + Single zone packaged rooftop unit with fuel-fired furnace and baseboards and fuel boiler for acs heating - domestic_hot_water + domestic_hot_water 3 - 2 - ??? + 5 + 1 false - - Electrical resistance furnace and electrical boiler for acs + + Single zone packaged rooftop unit with electrical resistance furnace and baseboards and fuel boiler for acs heating domestic_hot_water 4 - 2 - ??? + 5 + 1 false - - Baseboards: hydronic with fuel boiler + + Single zone make-up air unit with baseboard heating with fuel fired boiler heating domestic_hot_water @@ -113,68 +164,118 @@ 1 1 - ??? + 1 false - - Electrical baseboards and electrical boiler for acs + + Single zone make-up air unit with electrical baseboard heating and DHW with resistance heating domestic_hot_water 2 - 3 - ??? + 5 + 3 false - - Air cooled DX with external condenser + + Multi-zone built-up system with baseboard heater hydronic with fuel fired boiler - cooling + heating + domestic_hot_water - 5 - 3 - ??? - - false - - - Water cooled, water chiller - - cooling - - - 5 + 2 1 - ??? + 3 false - - Air cooled DX + + Multi-zone built-up system with electrical baseboard heater and electrical hot water - cooling + heating + domestic_hot_water - 5 - 3 - ??? + 2 + 1 + 3 false + Unitary air conditioner air cooled DX with external condenser + + cooling + + + 5 + 6 + 3 + + false + + + 4 pipe fan coils with water cooled, water chiller + + cooling + + + 5 + 2 + 2 + + false + + + Single zone packaged rooftop unit with air cooled DX + + cooling + + + 5 + 6 + 3 + + false + + + Single zone make-up air unit with air cooled DX + + cooling + + + 5 + 6 + 3 + + false + + + Multi-zone built-up system with water cooled, water chiller + + cooling + + + 5 + 3 + 3 + + false + + PV system electricity 6 - ??? - ??? + 5 + 3 true @@ -190,109 +291,109 @@ 1 7 - 10 + 15 - 2 - 7 + 1 + 10 2 - 7 10 + 15 - 1 - 8 + 2 + 11 - 1 - 8 - 10 + 2 + 11 + 15 - 2 - 8 + 3 + 11 - 2 - 8 - 10 + 3 + 11 + 15 - 3 4 + 12 - 3 4 - 10 + 12 + 15 - 4 - 4 + 5 + 12 - 4 - 4 - 10 + 5 + 12 + 15 - 8 + 11 - 8 - 10 + 11 + 15 - 5 8 + 14 - 5 8 - 10 + 14 + 15 - 6 - 8 + 9 + 14 - 6 - 8 - 10 + 9 + 14 + 15