<?xml version="1.0" encoding="UTF-8"?>
|
||
|
<encomp:EnergySystemCatalog xmi:version="2.0" xmlns:xmi="http://www.omg.org/XMI" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:encomp="https://www.hft-stuttgart.de/energycomponents">
|
||
|
<energycomponent>
|
||
|
<media name="Water" density="981.0" heatCapacity="4180.0" evaporationTemperature="100.0"/>
|
||
|
<boilers modelName="ALP080B" manufacturer="//@energycomponent.0/@manufacturers.0" installedThermalPower="21.0" modulationRange="0.88" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ALP105B" manufacturer="//@energycomponent.0/@manufacturers.0" installedThermalPower="28.0" modulationRange="0.88" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ALP150B" manufacturer="//@energycomponent.0/@manufacturers.0" installedThermalPower="40.0" modulationRange="0.88" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ALP210B" manufacturer="//@energycomponent.0/@manufacturers.0" installedThermalPower="57.0" modulationRange="0.87" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ALTAC-136" manufacturer="//@energycomponent.0/@manufacturers.1" installedThermalPower="33.0" modulationRange="0.95" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ALTAC-200" installedThermalPower="41.0" modulationRange="0.92" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ALTA-120" manufacturer="//@energycomponent.0/@manufacturers.1" installedThermalPower="33.0" modulationRange="0.95" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="ASPN-085" manufacturer="//@energycomponent.0/@manufacturers.2" installedThermalPower="23.15" modulationRange="0.97" nominalEfficiency="0.96"/>
|
||
|
<boilers modelName="ASPN-110" manufacturer="//@energycomponent.0/@manufacturers.2" installedThermalPower="30.19" modulationRange="0.96" nominalEfficiency="0.96"/>
|
||
|
<boilers modelName="ASPNC-155" manufacturer="//@energycomponent.0/@manufacturers.2" installedThermalPower="42.5" modulationRange="0.96" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="K2WTC-135B" manufacturer="//@energycomponent.0/@manufacturers.3" installedThermalPower="32.8" modulationRange="0.96" nominalEfficiency="0.95" combi="true"/>
|
||
|
<boilers modelName="K2WTC-180B" manufacturer="//@energycomponent.0/@manufacturers.3" installedThermalPower="49.5" modulationRange="0.96" nominalEfficiency="0.95" combi="true"/>
|
||
|
<heatPumps modelName="CMAA 012" description="A second degree equation is used in form of A*T_source^2 + B*T_source + C*T_source*T_sup + D*T_sup + E*T_sup^2 + F" manufacturer="//@energycomponent.0/@manufacturers.4" installedThermalPower="51.7" modulationRange="0.0" fuel="Electricity" nominalCOP="3.32" maxHeatingSupTemperature="55.0" minHeatingSupTemperature="6.0" maxCoolingSupTemperature="11.0" minCoolingSupTemperature="30.0">
|
||
|
<coefficientOfPerformance xsi:type="encomp:SecondDegreePolynomialFunction" parameter="COP" parameterA="9.5E-4" parameterB="0.177" parameterC="-0.00242" parameterD="-0.155" parameterE="9.3E-4" parameterF="8.044"/>
|
||
|
</heatPumps>
|
||
|
<heatPumps modelName="CMAA 70" description="A second degree equation is used in form of A*T_source^2 + B*T_source + C*T_source*T_sup + D*T_sup + E*T_sup^2 + F" manufacturer="//@energycomponent.0/@manufacturers.4" installedThermalPower="279.3" modulationRange="0.0" fuel="Electricity" nominalCOP="3.07" maxHeatingSupTemperature="55.0" minHeatingSupTemperature="6.0" maxCoolingSupTemperature="11.0" minCoolingSupTemperature="30.0">
|
||
|
<coefficientOfPerformance xsi:type="encomp:SecondDegreePolynomialFunction" parameter="COP" parameterA="0.0011" parameterB="0.207" parameterC="-0.00292" parameterD="-0.187" parameterE="0.00121" parameterF="8.95"/>
|
||
|
</heatPumps>
|
||
|
<heatPumps modelName="CMAA 140" description="A second degree equation is used in form of A*T_source^2 + B*T_source + C*T_source*T_sup + D*T_sup + E*T_sup^2 + F" manufacturer="//@energycomponent.0/@manufacturers.4" installedThermalPower="279.3" modulationRange="0.0" fuel="Electricity" nominalCOP="3.46" maxHeatingSupTemperature="55.0" minHeatingSupTemperature="6.0" maxCoolingSupTemperature="11.0" minCoolingSupTemperature="30.0">
|
||
|
<coefficientOfPerformance xsi:type="encomp:SecondDegreePolynomialFunction" parameter="COP" parameterA="0.00109" parameterB="0.209" parameterC="-0.00291" parameterD="-0.172" parameterE="0.00102" parameterF="8.95"/>
|
||
|
</heatPumps>
|
||
|
<thermalStorages modelName="HF 200" manufacturer="//@energycomponent.0/@manufacturers.5" volume="0.5" maxTemp="95.0" insulationThickness="90.0" usesMedium="//@energycomponent.0/@media.0" insulationMaterial="//@energycomponent.0/@materials.0" height="1.5" tankMaterial="//@energycomponent.0/@materials.1"/>
|
||
|
<thermalStorages modelName="HF 300" manufacturer="//@energycomponent.0/@manufacturers.5" volume="0.6" maxTemp="95.0" insulationThickness="90.0" usesMedium="//@energycomponent.0/@media.0" insulationMaterial="//@energycomponent.0/@materials.0" height="1.3" tankMaterial="//@energycomponent.0/@materials.1"/>
|
||
|
<thermalStorages modelName="HF 500" manufacturer="//@energycomponent.0/@manufacturers.5" volume="0.5" maxTemp="95.0" insulationThickness="90.0" usesMedium="//@energycomponent.0/@media.0" insulationMaterial="//@energycomponent.0/@materials.0" height="1.5" tankMaterial="//@energycomponent.0/@materials.1"/>
|
||
|
<thermalStorages modelName="HF 200" manufacturer="//@energycomponent.0/@manufacturers.5" volume="0.5" maxTemp="95.0" insulationThickness="90.0" usesMedium="//@energycomponent.0/@media.0" insulationMaterial="//@energycomponent.0/@materials.0" height="1.5" tankMaterial="//@energycomponent.0/@materials.1"/>
|
||
|
<thermalStorages modelName="HF 200" manufacturer="//@energycomponent.0/@manufacturers.5" volume="0.5" maxTemp="95.0" insulationThickness="90.0" usesMedium="//@energycomponent.0/@media.0" insulationMaterial="//@energycomponent.0/@materials.0" height="1.5" tankMaterial="//@energycomponent.0/@materials.1"/>
|
||
|
<manufacturers name="Alpine" country="USA"/>
|
||
|
<manufacturers name="Alta" country="USA"/>
|
||
|
<manufacturers name="Aspen" country="USA"/>
|
||
|
<manufacturers name="K2" country="USA"/>
|
||
|
<manufacturers name="TRANE"/>
|
||
|
<manufacturers name="reflex"/>
|
||
|
<materials name="Polyurethane" thermalConductivity="0.028"/>
|
||
|
<materials name="Steel" thermalConductivity="18.0"/>
|
||
|
</energycomponent>
|
||
|
<energysystemconfiguration configurationName="PvHpBoiler"/>
|
||
|
<energysystemconfiguration configurationName="hpTesBoiler"/>
|
||
|
<energysystemconfiguration/>
|
||
|