diff --git a/hub/city_model_structure/building.py b/hub/city_model_structure/building.py index c21b1621..83f50143 100644 --- a/hub/city_model_structure/building.py +++ b/hub/city_model_structure/building.py @@ -10,8 +10,6 @@ import logging from typing import List, Union, TypeVar import numpy as np -import pandas as pd - import hub.helpers.constants as cte from hub.city_model_structure.attributes.polyhedron import Polyhedron from hub.city_model_structure.building_demand.household import Household @@ -731,9 +729,10 @@ class Building(CityObject): for _key in self.roofs[0].global_irradiance.keys(): _results = [0 for _ in range(0, len(self.roofs[0].global_irradiance[_key][cte.SRA]))] for surface in self.roofs: - _results = [x + y * _efficiency * surface.perimeter_area - * surface.solar_collectors_area_reduction_factor * z - for x, y, z in zip(_results, surface.global_irradiance[_key][cte.SRA], - orientation_losses_factor[cte.MONTH]['south'])] + if _key in orientation_losses_factor: + _results = [x + y * _efficiency * surface.perimeter_area + * surface.solar_collectors_area_reduction_factor * z + for x, y, z in zip(_results, surface.global_irradiance[_key][cte.SRA], + orientation_losses_factor[_key]['south'])] self._onsite_electrical_production[_key] = _results return self._onsite_electrical_production diff --git a/hub/data/energy_systems/montreal_custom_systems.xml b/hub/data/energy_systems/montreal_custom_systems.xml index ed657e5a..be67a4ea 100644 --- a/hub/data/energy_systems/montreal_custom_systems.xml +++ b/hub/data/energy_systems/montreal_custom_systems.xml @@ -192,29 +192,29 @@ 3 - - Multi-zone built-up system with baseboard heater hydronic with fuel fired boiler - - heating - domestic_hot_water - - - 2 - 1 - 3 - + + Multi-zone built-up system with baseboard heater hydronic with fuel fired boiler + + heating + domestic_hot_water + + + 2 + 1 + 3 + - - Multi-zone built-up system with electrical baseboard heater and electrical hot water - - heating - domestic_hot_water - - - 2 - 1 - 3 - + + Multi-zone built-up system with electrical baseboard heater and electrical hot water + + heating + domestic_hot_water + + + 2 + 1 + 3 + Unitary air conditioner air cooled DX with external condenser diff --git a/tests/test_systems_factory.py b/tests/test_systems_factory.py index ac322c88..0305c23a 100644 --- a/tests/test_systems_factory.py +++ b/tests/test_systems_factory.py @@ -112,3 +112,4 @@ class TestSystemsFactory(TestCase): self.assertLess(0, building.cooling_consumption[cte.YEAR][0]) self.assertLess(0, building.domestic_hot_water_consumption[cte.YEAR][0]) self.assertLess(0, building.onsite_electrical_production[cte.YEAR][0]) + print(building.heating_consumption[cte.YEAR][0], building.cooling_consumption[cte.YEAR][0], building.domestic_hot_water_consumption[cte.YEAR][0], building.onsite_electrical_production[cte.YEAR][0]) \ No newline at end of file