changed all the singular names to plural and turned distribution and emission systems into lists
This commit is contained in:
parent
cbda6ce13d
commit
ca48d6448b
|
@ -706,11 +706,11 @@ class Building(CityObject):
|
|||
if self.energy_systems is None:
|
||||
return self._distribution_systems_electrical_consumption
|
||||
for energy_system in self.energy_systems:
|
||||
emission_system = energy_system.emission_system.generic_emission_system
|
||||
emission_system = energy_system.emission_systems.generic_emission_system
|
||||
parasitic_energy_consumption = 0
|
||||
if emission_system is not None:
|
||||
parasitic_energy_consumption = emission_system.parasitic_energy_consumption
|
||||
distribution_system = energy_system.distribution_system.generic_distribution_system
|
||||
distribution_system = energy_system.distribution_systems.generic_distribution_system
|
||||
consumption_variable_flow = distribution_system.distribution_consumption_variable_flow
|
||||
for demand_type in energy_system.demand_types:
|
||||
if demand_type.lower() == cte.HEATING.lower():
|
||||
|
@ -744,7 +744,9 @@ class Building(CityObject):
|
|||
if self.energy_systems is None:
|
||||
return None
|
||||
for energy_system in self.energy_systems:
|
||||
generation_systems = energy_system.generation_system
|
||||
generation_systems = energy_system.generation_systems
|
||||
print(generation_systems)
|
||||
print(type(generation_systems))
|
||||
for demand_type in energy_system.demand_types:
|
||||
if demand_type.lower() == consumption_type.lower():
|
||||
if consumption_type in (cte.HEATING, cte.DOMESTIC_HOT_WATER):
|
||||
|
@ -786,8 +788,8 @@ class Building(CityObject):
|
|||
if self.energy_systems is None:
|
||||
return self._onsite_electrical_production
|
||||
for energy_system in self.energy_systems:
|
||||
if energy_system.generation_system.generic_generation_system.type == cte.PHOTOVOLTAIC:
|
||||
_efficiency = energy_system.generation_system.generic_generation_system.electricity_efficiency
|
||||
if energy_system.generation_systems.generic_generation_system.type == cte.PHOTOVOLTAIC:
|
||||
_efficiency = energy_system.generation_systems.generic_generation_system.electricity_efficiency
|
||||
self._onsite_electrical_production = {}
|
||||
for _key in self.roofs[0].global_irradiance.keys():
|
||||
_results = [0 for _ in range(0, len(self.roofs[0].global_irradiance[_key]))]
|
||||
|
|
|
@ -23,12 +23,12 @@ class EnergySystem:
|
|||
def __init__(self):
|
||||
self._name = None
|
||||
self._demand_types = None
|
||||
self._generation_system = None
|
||||
self._distribution_system = None
|
||||
self._emission_system = None
|
||||
self._generation_systems = None
|
||||
self._distribution_systems = None
|
||||
self._emission_systems = None
|
||||
self._connected_city_objects = None
|
||||
self._control_system = None
|
||||
self._energy_storage_system = None
|
||||
self._energy_storage_systems = None
|
||||
|
||||
@property
|
||||
def name(self):
|
||||
|
@ -63,52 +63,52 @@ class EnergySystem:
|
|||
self._demand_types = value
|
||||
|
||||
@property
|
||||
def generation_system(self) -> List[GenerationSystem]:
|
||||
def generation_systems(self) -> List[GenerationSystem]:
|
||||
"""
|
||||
Get generation systems
|
||||
:return: GenerationSystem
|
||||
"""
|
||||
return self._generation_system
|
||||
return self._generation_systems
|
||||
|
||||
@generation_system.setter
|
||||
def generation_system(self, value):
|
||||
@generation_systems.setter
|
||||
def generation_systems(self, value):
|
||||
"""
|
||||
Set generation system
|
||||
:param value: GenerationSystem
|
||||
"""
|
||||
self._generation_system = value
|
||||
self._generation_systems = value
|
||||
|
||||
@property
|
||||
def distribution_system(self) -> Union[None, DistributionSystem]:
|
||||
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
|
||||
"""
|
||||
Get distribution system
|
||||
:return: DistributionSystem
|
||||
"""
|
||||
return self._distribution_system
|
||||
return self._distribution_systems
|
||||
|
||||
@distribution_system.setter
|
||||
def distribution_system(self, value):
|
||||
@distribution_systems.setter
|
||||
def distribution_systems(self, value):
|
||||
"""
|
||||
Set distribution system
|
||||
:param value: DistributionSystem
|
||||
"""
|
||||
self._distribution_system = value
|
||||
self._distribution_systems = value
|
||||
|
||||
@property
|
||||
def emission_system(self) -> Union[None, EmissionSystem]:
|
||||
def emission_systems(self) -> Union[None, List[EmissionSystem]]:
|
||||
"""
|
||||
Get emission system
|
||||
:return: EmissionSystem
|
||||
"""
|
||||
return self._emission_system
|
||||
return self._emission_systems
|
||||
|
||||
@emission_system.setter
|
||||
def emission_system(self, value):
|
||||
@emission_systems.setter
|
||||
def emission_systems(self, value):
|
||||
"""
|
||||
Set emission system
|
||||
:param value: EmissionSystem
|
||||
"""
|
||||
self._emission_system = value
|
||||
self._emission_systems = value
|
||||
|
||||
@property
|
||||
def connected_city_objects(self) -> Union[None, List[CityObject]]:
|
||||
|
@ -143,17 +143,17 @@ class EnergySystem:
|
|||
self._control_system = value
|
||||
|
||||
@property
|
||||
def energy_storage_system(self) -> Union[None, List[ThermalStorageSystem], List[ElectricalStorageSystem]]:
|
||||
def energy_storage_systems(self) -> Union[None, List[ThermalStorageSystem], List[ElectricalStorageSystem]]:
|
||||
"""
|
||||
Get energy storage systems
|
||||
:return: [EnergyStorageSystem]
|
||||
"""
|
||||
return self._energy_storage_system
|
||||
return self._energy_storage_systems
|
||||
|
||||
@energy_storage_system.setter
|
||||
def energy_storage_system(self, value):
|
||||
@energy_storage_systems.setter
|
||||
def energy_storage_systems(self, value):
|
||||
"""
|
||||
Set storage system
|
||||
:param value: [EnergyStorageSystem]
|
||||
"""
|
||||
self._energy_storage_system = value
|
||||
self._energy_storage_systems = value
|
||||
|
|
|
@ -86,7 +86,7 @@ class MontrealCustomEnergySystemParameters:
|
|||
energy_system.name = system.name
|
||||
energy_system.demand_types = _hub_demand_types
|
||||
_generation_system = GenericGenerationSystem()
|
||||
archetype_generation_equipment = system.generation_system
|
||||
archetype_generation_equipment = system.generation_systems
|
||||
_type = system.name
|
||||
_generation_system.type = Dictionaries().montreal_system_to_hub_energy_generation_system[
|
||||
_type]
|
||||
|
@ -145,11 +145,11 @@ class MontrealCustomEnergySystemParameters:
|
|||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.generation_system)
|
||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
||||
|
||||
_building_energy_equipment.generation_system = _building_generation_system
|
||||
_building_energy_equipment.distribution_system = _building_distribution_system
|
||||
_building_energy_equipment.emission_system = _building_emission_system
|
||||
_building_energy_equipment.generation_systems = _building_generation_system
|
||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
||||
_building_energy_equipment.emission_systems = _building_emission_system
|
||||
|
||||
_building_energy_systems.append(_building_energy_equipment)
|
||||
building.energy_systems = _building_energy_systems
|
||||
|
|
|
@ -154,21 +154,21 @@ class NorthAmericaCustomEnergySystemParameters:
|
|||
|
||||
_building_distribution_system = DistributionSystem()
|
||||
_building_distribution_system.generic_distribution_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_system)
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_systems)
|
||||
_building_emission_system = EmissionSystem()
|
||||
_building_emission_system.generic_emission_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.emission_system)
|
||||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.generation_system)
|
||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
||||
_building_storage_system = ThermalStorageSystem()
|
||||
_building_storage_system.generic_storage_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_system)
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_systems)
|
||||
|
||||
_building_energy_equipment.generation_system = _building_generation_system
|
||||
_building_energy_equipment.distribution_system = _building_distribution_system
|
||||
_building_energy_equipment.emission_system = _building_emission_system
|
||||
_building_energy_equipment.energy_storage_system = _building_storage_system
|
||||
_building_energy_equipment.generation_systems = _building_generation_system
|
||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
||||
_building_energy_equipment.emission_systems = _building_emission_system
|
||||
_building_energy_equipment.energy_storage_systems = _building_storage_system
|
||||
|
||||
_building_energy_systems.append(_building_energy_equipment)
|
||||
building.energy_systems = _building_energy_systems
|
||||
|
|
|
@ -98,15 +98,15 @@ class TestSystemsFactory(TestCase):
|
|||
)
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.generation_system)
|
||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
||||
)
|
||||
if cte.HEATING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
||||
if cte.COOLING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.cooling_power = building.cooling_peak_load[cte.YEAR][0]
|
||||
_building_energy_equipment.generation_system = _building_generation_system
|
||||
_building_energy_equipment.distribution_system = _building_distribution_system
|
||||
_building_energy_equipment.emission_system = _building_emission_system
|
||||
_building_energy_equipment.generation_systems = _building_generation_system
|
||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
||||
_building_energy_equipment.emission_systems = _building_emission_system
|
||||
|
||||
_building_energy_systems.append(_building_energy_equipment)
|
||||
building.energy_systems = _building_energy_systems
|
||||
|
@ -161,27 +161,27 @@ class TestSystemsFactory(TestCase):
|
|||
|
||||
_building_distribution_system = DistributionSystem()
|
||||
_building_distribution_system.generic_distribution_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_system)
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_systems)
|
||||
)
|
||||
_building_emission_system = EmissionSystem()
|
||||
_building_emission_system.generic_emission_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.emission_system)
|
||||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
||||
)
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.generation_system)
|
||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
||||
)
|
||||
_building_storage_system = ThermalStorageSystem()
|
||||
_building_storage_system.generic_storage_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_system)
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_systems)
|
||||
|
||||
if cte.HEATING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
||||
if cte.COOLING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.cooling_power = building.cooling_peak_load[cte.YEAR][0]
|
||||
_building_energy_equipment.generation_system = _building_generation_system
|
||||
_building_energy_equipment.distribution_system = _building_distribution_system
|
||||
_building_energy_equipment.emission_system = _building_emission_system
|
||||
_building_energy_equipment.generation_systems = _building_generation_system
|
||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
||||
_building_energy_equipment.emission_systems = _building_emission_system
|
||||
|
||||
_building_energy_systems.append(_building_energy_equipment)
|
||||
building.energy_systems = _building_energy_systems
|
||||
|
|
Loading…
Reference in New Issue
Block a user