<?xml version="1.0" encoding="utf-8"?> <library name="us_library"> <windows> <window type="skylight" id="1" name="189.1-2009 Nonres 4B Skylight without Curb"> <shgc>0.32</shgc> <frame_ratio units="-">0</frame_ratio> <thickness units="m">0.003</thickness> <solar_transmittance_at_normal_incidence units="-">0.301483</solar_transmittance_at_normal_incidence> <front_side_solar_transmittance_at_normal_incidence units="-">0.648517</front_side_solar_transmittance_at_normal_incidence> <back_side_solar_transmittance_at_normal_incidence units="-">0.648517</back_side_solar_transmittance_at_normal_incidence> <conductivity units="W/m K">0.0133144</conductivity> </window> <window type="skylight" id="2" name="90.1-2004 Nonres 4B Skylight without Curb"> <shgc>0.49</shgc> <frame_ratio units="-">0</frame_ratio> <thickness units="m">0.003</thickness> <solar_transmittance_at_normal_incidence units="-">0.481761</solar_transmittance_at_normal_incidence> <front_side_solar_transmittance_at_normal_incidence units="-">0.468239</front_side_solar_transmittance_at_normal_incidence> <back_side_solar_transmittance_at_normal_incidence units="-">0.468239</back_side_solar_transmittance_at_normal_incidence> <conductivity units="W/m K">0.03026</conductivity> </window> <window type="window" id="3" name="189.1-2009 Nonres 4B Window Nonmetal framing"> <shgc>0.35</shgc> <frame_ratio units="-">0</frame_ratio> <thickness units="m">0.003</thickness> <solar_transmittance_at_normal_incidence units="-">0.328881</solar_transmittance_at_normal_incidence> <front_side_solar_transmittance_at_normal_incidence units="-">0.621119</front_side_solar_transmittance_at_normal_incidence> <back_side_solar_transmittance_at_normal_incidence units="-">0.621119</back_side_solar_transmittance_at_normal_incidence> <conductivity units="W/m K">0.0071399</conductivity> </window> <window type="window" id="4" name="90.1-2004 Nonres 4B Window Fixed"> <shgc>0.36</shgc> <frame_ratio units="-">0</frame_ratio> <thickness units="m">0.003</thickness> <solar_transmittance_at_normal_incidence units="-">0.354957</solar_transmittance_at_normal_incidence> <front_side_solar_transmittance_at_normal_incidence units="-">0.595043</front_side_solar_transmittance_at_normal_incidence> <back_side_solar_transmittance_at_normal_incidence units="-">0.595043</back_side_solar_transmittance_at_normal_incidence> <conductivity units="W/m K">0.0134755</conductivity> </window> </windows> <materials> <material id="1" name="MAT-CC05 8 HW CONCRETE"> <conductivity units="W/m K">1.311</conductivity> <density units="kg/m3">2240</density> <specific_heat units="J/kg K">836.8</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="2" name="CP02 CARPET PAD"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.21648</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.8</visible_absorptance> </material> <material id="3" name="Floor Insulation [4]"> <conductivity units="W/m K">0.045</conductivity> <density units="kg/m3">265</density> <specific_heat units="J/kg K">836.8</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="4" name="1IN Stucco"> <conductivity units="W/m K">0.6918</conductivity> <density units="kg/m3">1858</density> <specific_heat units="J/kg K">837</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.92</solar_absorptance> <visible_absorptance units="-">0.92</visible_absorptance> </material> <material id="5" name="8IN Concrete HW"> <conductivity units="W/m K">1.7296</conductivity> <density units="kg/m3">2243</density> <specific_heat units="J/kg K">837</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.65</solar_absorptance> <visible_absorptance units="-">0.65</visible_absorptance> </material> <material id="6" name="Wall Insulation [37]"> <conductivity units="W/m K">0.0432</conductivity> <density units="kg/m3">91</density> <specific_heat units="J/kg K">837</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.5</solar_absorptance> <visible_absorptance units="-">0.5</visible_absorptance> </material> <material id="7" name="1/2IN Gypsum"> <conductivity units="W/m K">0.16</conductivity> <density units="kg/m3">784.9</density> <specific_heat units="J/kg K">830</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.92</solar_absorptance> <visible_absorptance units="-">0.92</visible_absorptance> </material> <material id="8" name="Wood Siding"> <conductivity units="W/m K">0.11</conductivity> <density units="kg/m3">544.62</density> <specific_heat units="J/kg K">1210</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.78</solar_absorptance> <visible_absorptance units="-">0.78</visible_absorptance> </material> <material id="9" name="Wood Shingles"> <conductivity units="W/m K">0.115</conductivity> <density units="kg/m3">513</density> <specific_heat units="J/kg K">1255</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.78</solar_absorptance> <visible_absorptance units="-">0.78</visible_absorptance> </material> <material id="10" name="1IN Wood Decking"> <conductivity units="W/m K">0.1211</conductivity> <density units="kg/m3">593</density> <specific_heat units="J/kg K">2510</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.78</solar_absorptance> <visible_absorptance units="-">0.78</visible_absorptance> </material> <material id="11" name="Roof Insulation [23]"> <conductivity units="W/m K">0.049</conductivity> <density units="kg/m3">265</density> <specific_heat units="J/kg K">836.8</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="12" name="MAT-SHEATH"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.36256</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="13" name="MAT-SHEATH"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.36256</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="14" name="Metal Decking"> <conductivity units="W/m K">45.006</conductivity> <density units="kg/m3">7680</density> <specific_heat units="J/kg K">418.4</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.3</visible_absorptance> </material> <material id="15" name="Roof Membrane"> <conductivity units="W/m K">0.16</conductivity> <density units="kg/m3">1121.29</density> <specific_heat units="J/kg K">1460</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="16" name="CP02 CARPET PAD"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.21648</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.8</visible_absorptance> </material> <material id="17" name="MAT-SHEATH"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.36256</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="18" name="CP02 CARPET PAD"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.21648</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.8</visible_absorptance> </material> <material id="19" name="MAT-SHEATH"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.36256</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="20" name="CP02 CARPET PAD"> <no_mass>true</no_mass> <thermal_resistance units="m2 K/W">0.21648</thermal_resistance> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.8</visible_absorptance> </material> <material id="21" name="Wall Insulation [38]"> <conductivity units="W/m K">0.045</conductivity> <density units="kg/m3">265</density> <specific_heat units="J/kg K">836.8</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.7</solar_absorptance> <visible_absorptance units="-">0.7</visible_absorptance> </material> <material id="22" name="metal siding"> <conductivity units="W/m K">44.96</conductivity> <density units="kg/m3">7688.86</density> <specific_heat units="J/kg K">410</specific_heat> <thermal_absorptance units="-">0.9</thermal_absorptance> <solar_absorptance units="-">0.2</solar_absorptance> <visible_absorptance units="-">0.2</visible_absorptance> </material> </materials> <constructions> <construction type="exterior slab" id="1" name="189.1-2009 Nonres 4B Exposed Floor Mass"> <layers> <layer id="1" name="Layer 1"> <material>3</material> <thickness units="m">0.0795397</thickness> </layer> <layer id="2" name="Layer 2"> <material>1</material> <thickness units="m">0.20321</thickness> </layer> <layer id="3" name="Layer 3"> <material>2</material> </layer> </layers> </construction> <construction type="exterior wall" id="2" name="189.1-2009 Nonres 4B Ext Wall Mass"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>4</material> <thickness units="m">0.0253</thickness> </layer> <layer id="2" name="Layer 2"> <material>5</material> <thickness units="m">0.2033</thickness> </layer> <layer id="3" name="Layer 3"> <material>6</material> <thickness units="m">0.0680962</thickness> </layer> <layer id="4" name="Layer 4"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="exterior wall" id="3" name="90.1-2004 Nonres 4B Ext Wall Wood-Framed and Other"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>8</material> <thickness units="m">0.01</thickness> </layer> <layer id="2" name="Layer 2"> <material>3</material> <thickness units="m">0.0746874</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="roof" id="4" name="189.1-2009 Nonres 4B Roof Attic and Other"> <outside_solar_absorptance units="-">0.78</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.78</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>9</material> <thickness units="m">0.0178</thickness> </layer> <layer id="2" name="Layer 2"> <material>10</material> <thickness units="m">0.0254</thickness> </layer> <layer id="3" name="Layer 3"> <material>11</material> <thickness units="m">0.375211</thickness> </layer> <layer id="4" name="Layer 4"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="roof" id="5" name="90.1-2004 Nonres 4B Roof Attic and Other"> <outside_solar_absorptance units="-">0.78</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.78</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>9</material> <thickness units="m">0.0178</thickness> </layer> <layer id="2" name="Layer 2"> <material>10</material> <thickness units="m">0.0254</thickness> </layer> <layer id="3" name="Layer 3"> <material>11</material> <thickness units="m">0.221604</thickness> </layer> <layer id="4" name="Layer 4"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="exterior wall" id="6" name="189.1-2009 Nonres 4B Ext Wall Steel-Framed"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>12</material> </layer> <layer id="2" name="Layer 2"> <material>3</material> <thickness units="m">0.118387</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="7" name="189.1-2009 Nonres 4B Ext Slab Unheated - 8in Slab without Carpet"> <layers> <layer id="1" name="Layer 1"> <material>1</material> <thickness units="m">0.20321</thickness> </layer> </layers> </construction> <construction type="exterior wall" id="8" name="90.1-2004 Nonres 4B Ext Wall Steel-Framed"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>13</material> </layer> <layer id="2" name="Layer 2"> <material>3</material> <thickness units="m">0.0373223</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="roof" id="9" name="189.1-2009 Nonres 4B Roof IEAD"> <outside_solar_absorptance units="-">0.7</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.7</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>15</material> <thickness units="m">0.0095</thickness> </layer> <layer id="2" name="Layer 2"> <material>11</material> <thickness units="m">0.210538</thickness> </layer> <layer id="3" name="Layer 3"> <material>14</material> <thickness units="m">0.001524</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="10" name="189.1-2009 Nonres 4B Ext Slab Unheated - 4in Slab without Carpet"> <layers> <layer id="1" name="Layer 1"> <material>1</material> <thickness units="m">0.1016</thickness> </layer> </layers> </construction> <construction type="roof" id="11" name="189.1-2009 Nonres 4B Roof Metal Building"> <outside_solar_absorptance units="-">0.7</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.3</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>14</material> <thickness units="m">0.001524</thickness> </layer> <layer id="2" name="Layer 2"> <material>11</material> <thickness units="m">0.23578</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="12" name="189.1-2009 Nonres 4B Ext Slab Unheated - 4in Slab with Carpet"> <layers> <layer id="1" name="Layer 1"> <material>1</material> <thickness units="m">0.1016</thickness> </layer> <layer id="2" name="Layer 2"> <material>16</material> </layer> </layers> </construction> <construction type="exterior wall" id="13" name="90.1-2004 Nonres 4B Ext Wall Mass"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>4</material> <thickness units="m">0.0253</thickness> </layer> <layer id="2" name="Layer 2"> <material>5</material> <thickness units="m">0.2033</thickness> </layer> <layer id="3" name="Layer 3"> <material>6</material> <thickness units="m">0.0338606</thickness> </layer> <layer id="4" name="Layer 4"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="roof" id="14" name="90.1-2004 Nonres 4B Roof Metal Building"> <outside_solar_absorptance units="-">0.7</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.3</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>14</material> <thickness units="m">0.001524</thickness> </layer> <layer id="2" name="Layer 2"> <material>11</material> <thickness units="m">0.123533</thickness> </layer> </layers> </construction> <construction type="exterior wall" id="15" name="189.1-2009 Res 4B Ext Wall Steel-Framed"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>17</material> </layer> <layer id="2" name="Layer 2"> <material>3</material> <thickness units="m">0.118387</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="exterior wall" id="16" name="189.1-2009 Nonres 4B Ext Wall Wood-Framed and Other"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>8</material> <thickness units="m">0.01</thickness> </layer> <layer id="2" name="Layer 2"> <material>3</material> <thickness units="m">0.110422</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="roof" id="17" name="90.1-2004 Nonres 4B Roof IEAD"> <outside_solar_absorptance units="-">0.7</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.7</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>15</material> <thickness units="m">0.0095</thickness> </layer> <layer id="2" name="Layer 2"> <material>11</material> <thickness units="m">0.124958</thickness> </layer> <layer id="3" name="Layer 3"> <material>14</material> <thickness units="m">0.001524</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="18" name="90.1-2004 Nonres 4B Exposed Floor Mass"> <layers> <layer id="1" name="Layer 1"> <material>3</material> <thickness units="m">0.0463846</thickness> </layer> <layer id="2" name="Layer 2"> <material>1</material> <thickness units="m">0.20321</thickness> </layer> <layer id="3" name="Layer 3"> <material>18</material> </layer> </layers> </construction> <construction type="exterior wall" id="19" name="90.1-2004 Res 4B Ext Wall Steel-Framed"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>19</material> </layer> <layer id="2" name="Layer 2"> <material>3</material> <thickness units="m">0.0971136</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="20" name="90.1-2004 Nonres 4B Ext Slab Unheated - 8in Slab without Carpet"> <layers> <layer id="1" name="Layer 1"> <material>1</material> <thickness units="m">0.20321</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="21" name="90.1-2004 Nonres 4B Ext Slab Unheated - 4in Slab without Carpet"> <layers> <layer id="1" name="Layer 1"> <material>1</material> <thickness units="m">0.1016</thickness> </layer> </layers> </construction> <construction type="exterior slab" id="22" name="90.1-2004 Nonres 4B Ext Slab Unheated - 4in Slab with Carpet"> <layers> <layer id="1" name="Layer 1"> <material>1</material> <thickness units="m">0.1016</thickness> </layer> <layer id="2" name="Layer 2"> <material>20</material> </layer> </layers> </construction> <construction type="exterior wall" id="23" name="189.1-2009 Nonres 4B Ext Wall Metal Building"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>22</material> <thickness units="m">0.0015</thickness> </layer> <layer id="2" name="Layer 2"> <material>21</material> <thickness units="m">0.139618</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> <construction type="exterior wall" id="24" name="90.1-2004 Nonres 4B Ext Wall Metal Building"> <outside_solar_absorptance units="-">0.92</outside_solar_absorptance> <outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance> <outside_visible_absorptance units="-">0.92</outside_visible_absorptance> <layers> <layer id="1" name="Layer 1"> <material>22</material> <thickness units="m">0.0015</thickness> </layer> <layer id="2" name="Layer 2"> <material>21</material> <thickness units="m">0.0598725</thickness> </layer> <layer id="3" name="Layer 3"> <material>7</material> <thickness units="m">0.01271</thickness> </layer> </layers> </construction> </constructions> </library>