final code for the paper

This commit is contained in:
Saeed Ranjbar 2024-02-07 09:58:50 -05:00
parent 4856173b88
commit 053549d0ec
29 changed files with 706 additions and 300116 deletions

View File

@ -115,7 +115,7 @@
<demand>domestic_hot_water</demand> <demand>domestic_hot_water</demand>
</demands> </demands>
<components> <components>
<generation_id>21</generation_id> <generation_id>22</generation_id>
<generation_id>18</generation_id> <generation_id>18</generation_id>
</components> </components>
</system> </system>

View File

@ -25,12 +25,15 @@ class SystemSizing:
if 'Heating' in system.demand_types: if 'Heating' in system.demand_types:
for generation in system.generation_systems: for generation in system.generation_systems:
if generation.system_type == 'Heat Pump': if generation.system_type == 'Heat Pump':
generation.nominal_heat_output = 0.6 * sizing_demand / 1000 if 0.5 * sizing_demand / 1000 > float(building.cooling_peak_load[cte.YEAR][0]) / 1000:
generation.nominal_heat_output = 0.5 * sizing_demand / 1000
else:
generation.nominal_heat_output = float(building.cooling_peak_load[cte.YEAR][0]) / 1000
for storage in generation.energy_storage_systems: for storage in generation.energy_storage_systems:
if storage.type_energy_stored == 'thermal': if storage.type_energy_stored == 'thermal':
storage.volume = (sizing_demand * 1000) / (cte.WATER_HEAT_CAPACITY*cte.WATER_DENSITY) storage.volume = (sizing_demand * 1000) / (cte.WATER_HEAT_CAPACITY*cte.WATER_DENSITY * 7)
elif generation.system_type == 'Boiler': elif generation.system_type == 'Boiler':
generation.nominal_heat_output = 0.4 * sizing_demand / 1000 generation.nominal_heat_output = 0.2 * sizing_demand / 1000
else: else:
sizing_demand = peak_cooling_demand sizing_demand = peak_cooling_demand

View File

@ -8,43 +8,35 @@
"coordinates": [ "coordinates": [
[ [
[ [
-73.5680637695714, -73.59509637788739,
45.49212884162544 45.49281364112769
], ],
[ [
-73.56802228176146, -73.59525317914965,
45.49217205619571 45.49288964095017
], ],
[ [
-73.56815668696326, -73.59534657856186,
45.49223626189717 45.492794141682744
], ],
[ [
-73.56815766959974, -73.59518977760617,
45.49223524178655 45.492718240969886
], ],
[ [
-73.56818746886172, -73.59509637788739,
45.49224944155107 45.49281364112769
],
[
-73.56822816806918,
45.49220694186927
],
[
-73.5680637695714,
45.49212884162544
] ]
] ]
] ]
}, },
"id": 175785, "id": 173256,
"properties": { "properties": {
"name": "01044602", "name": "01038796",
"address": "rue Victor-Hugo (MTL) 1630", "address": "chemin Daulac (MTL) 3114",
"function": "1000", "function": 1000,
"height": 12, "height": 13,
"year_of_construction": 1986 "year_of_construction": 1930
} }
}, },
{ {
@ -54,35 +46,43 @@
"coordinates": [ "coordinates": [
[ [
[ [
-73.56802228176146, -73.59495217762556,
45.49217205619571 45.49258434114596
], ],
[ [
-73.56798225825526, -73.59506447776009,
45.492213743742184 45.49262414056201
], ],
[ [
-73.56811660206223, -73.59509957759138,
45.49227791893211 45.49263644101914
], ],
[ [
-73.56815668696326, -73.59518857897076,
45.49223626189717 45.49250494094539
], ],
[ [
-73.56802228176146, -73.59518327787326,
45.49217205619571 45.492503141173856
],
[
-73.59504537810399,
45.492454240550124
],
[
-73.59495217762556,
45.49258434114596
] ]
] ]
] ]
}, },
"id": 176293, "id": 173747,
"properties": { "properties": {
"name": "01044604", "name": "01038788",
"address": "rue Victor-Hugo (MTL) 1636", "address": "avenue De Ramezay (MTL) 3800",
"function": "1000", "function": 1000,
"height": 12, "height": 14,
"year_of_construction": 1986 "year_of_construction": 1951
} }
}, },
{ {
@ -92,43 +92,641 @@
"coordinates": [ "coordinates": [
[ [
[ [
-73.56809506939487, -73.59572637867028,
45.49209624228538 45.49180674006269
], ],
[ [
-73.56809246893268, -73.59571157860442,
45.4920988416879 45.49182414016925
], ],
[ [
-73.56821287000538, -73.59582677771033,
45.49216124158406 45.49187574057837
], ],
[ [
-73.56822186852654, -73.5958962785267,
45.49216584161625 45.491798741007244
], ],
[ [
-73.56826745951075, -73.5959641779001,
45.492118613912375 45.491829041154
], ],
[ [
-73.56813497596143, -73.5960138785881,
45.49205532773507 45.49177394147369
], ],
[ [
-73.56809506939487, -73.59580547784373,
45.49209624228538 45.49168084032369
],
[
-73.59577867873332,
45.49171054058562
],
[
-73.5957561785699,
45.49170034080995
],
[
-73.59574897848717,
45.491697541128836
],
[
-73.59567497831794,
45.491785340720504
],
[
-73.59572637867028,
45.49180674006269
] ]
] ]
] ]
}, },
"id": 182393, "id": 173992,
"properties": { "properties": {
"name": "01044601", "name": "01005853",
"address": "rue Victor-Hugo (MTL) 1626", "address": "avenue Montrose (WMT) 3995",
"function": "1000", "function": 1000,
"height": 8, "height": 13,
"year_of_construction": 1986 "year_of_construction": 1954
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59560547830729,
45.49201724126733
],
[
-73.59564657763075,
45.4919762414193
],
[
-73.59566047853156,
45.491983140587905
],
[
-73.59568857819819,
45.49195524075527
],
[
-73.59567457878534,
45.49194834077272
],
[
-73.59572557806185,
45.491897540490385
],
[
-73.59566257732278,
45.49186634075404
],
[
-73.59567707799737,
45.49185194098785
],
[
-73.59560587839097,
45.49181664119461
],
[
-73.59547137776998,
45.4919508404886
],
[
-73.59560547830729,
45.49201724126733
]
]
]
},
"id": 173993,
"properties": {
"name": "01005854",
"address": "avenue Montrose (WMT) 3993",
"function": 1000,
"height": 13,
"year_of_construction": 1931
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59514017772527,
45.492325841049876
],
[
-73.59510907875664,
45.492364440599225
],
[
-73.5952345775676,
45.49241444119874
],
[
-73.59529957860164,
45.49232514127043
],
[
-73.59529967788879,
45.492324840639384
],
[
-73.59527827884438,
45.49231674098983
],
[
-73.59530667808272,
45.49227964098859
],
[
-73.59521127786968,
45.49224344060025
],
[
-73.59520767780707,
45.492242040742724
],
[
-73.59514017772527,
45.492325841049876
]
]
]
},
"id": 174567,
"properties": {
"name": "01005923",
"address": "road Ramezay (WMT) 32",
"function": 1000,
"height": 21,
"year_of_construction": 1939
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59529227869712,
45.49215394106806
],
[
-73.59541727736064,
45.492204940713805
],
[
-73.59551477809944,
45.492086541316965
],
[
-73.59547127904294,
45.49206884083843
],
[
-73.59548757788932,
45.49204944005538
],
[
-73.59540597740202,
45.49201614108959
],
[
-73.59529227869712,
45.49215394106806
]
]
]
},
"id": 174568,
"properties": {
"name": "01005925",
"address": "road Ramezay (WMT) 26",
"function": 1000,
"height": 13,
"year_of_construction": 1953
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59557527747081,
45.49249274099106
],
[
-73.5955776782368,
45.492493840392406
],
[
-73.59564767744641,
45.4924211409226
],
[
-73.59566077780735,
45.49242744056445
],
[
-73.59576217890702,
45.492317839977375
],
[
-73.59576587875681,
45.49231394054712
],
[
-73.59574637829832,
45.49230584119319
],
[
-73.5957769778866,
45.49226954009252
],
[
-73.59573237823915,
45.49225104067467
],
[
-73.595759678252,
45.49221854058899
],
[
-73.59576247874607,
45.49221544097501
],
[
-73.59571317766962,
45.49219564071571
],
[
-73.59570967816335,
45.492193941141394
],
[
-73.59556387815678,
45.49234464145987
],
[
-73.59559377843698,
45.49235924072013
],
[
-73.59550567908822,
45.49244844045095
],
[
-73.59547987740228,
45.4924357409139
],
[
-73.59547007845468,
45.492445641098996
],
[
-73.5954676789941,
45.492448340839374
],
[
-73.59557527747081,
45.49249274099106
]
]
]
},
"id": 176023,
"properties": {
"name": "01005825",
"address": "Daulac Road (WMT) 3120",
"function": 1000,
"height": 14,
"year_of_construction": 1929
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59582577744078,
45.49211804086734
],
[
-73.59589807808007,
45.49207884143549
],
[
-73.59593227860105,
45.492110140819
],
[
-73.59613727753961,
45.49199924074906
],
[
-73.59605087822372,
45.491920341240096
],
[
-73.5959825785232,
45.49195724100361
],
[
-73.59595687904626,
45.49193384053109
],
[
-73.59595357854774,
45.49193104118643
],
[
-73.59585637826699,
45.49198904131649
],
[
-73.59585607905447,
45.49198914055052
],
[
-73.59586937811612,
45.49200024157482
],
[
-73.5957667781599,
45.49206104107807
],
[
-73.59576467812714,
45.492062240532306
],
[
-73.59582577744078,
45.49211804086734
]
]
]
},
"id": 179876,
"properties": {
"name": "01005823",
"address": "Daulac Road (WMT) 3122",
"function": 1000,
"height": 12,
"year_of_construction": 1929
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59498007795506,
45.49295884146554
],
[
-73.59496817826819,
45.492971940501924
],
[
-73.59502897888328,
45.49299684173239
],
[
-73.59502797776138,
45.49299724029665
],
[
-73.59506007809205,
45.49301214021248
],
[
-73.59511047800927,
45.4930353412492
],
[
-73.59520987772127,
45.492928041034226
],
[
-73.59506867864944,
45.49286324113472
],
[
-73.59498007795506,
45.49295884146554
]
]
]
},
"id": 15,
"properties": {
"name": "01038794",
"address": "chemin Daulac (MTL) 3110",
"function": 1000,
"height": 13,
"year_of_construction": 1967
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59583697807957,
45.491646240954296
],
[
-73.59600577760085,
45.49172284068674
],
[
-73.59605407779563,
45.49167034091733
],
[
-73.59596717779193,
45.491630740692706
],
[
-73.59602227815309,
45.491570841196065
],
[
-73.59603597767651,
45.491555640295154
],
[
-73.59595787784414,
45.49152074065276
],
[
-73.59593837816067,
45.49154234071484
],
[
-73.59591807814743,
45.49156504015628
],
[
-73.59591337792143,
45.49156294026539
],
[
-73.59583697807957,
45.491646240954296
]
]
]
},
"id": 182412,
"properties": {
"name": "01005850",
"address": "avenue Montrose (WMT) 3999",
"function": 1000,
"height": 15,
"year_of_construction": 1949
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.59537137784395,
45.492706341116616
],
[
-73.59540947773887,
45.49266694108776
],
[
-73.5954206779499,
45.49267234069944
],
[
-73.59544417824509,
45.49264804055234
],
[
-73.59545397869982,
45.49265264136828
],
[
-73.59551157860325,
45.492593840550306
],
[
-73.59537919137715,
45.49252980302974
],
[
-73.59536586661991,
45.492525477802715
],
[
-73.59524697901422,
45.49264674020794
],
[
-73.59537137784395,
45.492706341116616
]
]
]
},
"id": 19,
"properties": {
"name": "01038798",
"address": "chemin Daulac (MTL) 3118",
"function": 1000,
"height": 15,
"year_of_construction": 1936
}
},
{
"type": "Feature",
"geometry": {
"type": "Polygon",
"coordinates": [
[
[
-73.5948600788741,
45.49281614121024
],
[
-73.59502657807683,
45.492830641494535
],
[
-73.59502657773935,
45.492830440829415
],
[
-73.59503387727392,
45.4927774410954
],
[
-73.59503387838534,
45.49277734121168
],
[
-73.59500297799816,
45.4927744406205
],
[
-73.59501737824803,
45.49269704018758
],
[
-73.59494597817641,
45.492690541488855
],
[
-73.59495047783913,
45.492666141155276
],
[
-73.59495037804294,
45.492666140338386
],
[
-73.59488757740115,
45.49266064048112
],
[
-73.5948600788741,
45.49281614121024
]
]
]
},
"id": 182671,
"properties": {
"name": "01038790",
"address": "avenue De Ramezay (MTL) 3878",
"function": 1000,
"height": 10,
"year_of_construction": 1933
} }
} }
] ]

38
main.py
View File

@ -1,3 +1,5 @@
import csv
from geojson_creator import process_geojson from geojson_creator import process_geojson
from pathlib import Path from pathlib import Path
from scripts.ep_workflow import energy_plus_workflow from scripts.ep_workflow import energy_plus_workflow
@ -13,7 +15,8 @@ from hub.imports.energy_systems.energy_system_sizing import SystemSizing
from system_simulation import SystemSimulation from system_simulation import SystemSimulation
from hub.helpers.monthly_values import MonthlyValues from hub.helpers.monthly_values import MonthlyValues
geojson_file = process_geojson(x=-73.5681295982132, y=45.49218262677643, diff=0.0001)
geojson_file = Path('./input_files/output_buildings.geojson').resolve()
file_path = (Path(__file__).parent.parent / 'input_files' / f'{geojson_file}') file_path = (Path(__file__).parent.parent / 'input_files' / f'{geojson_file}')
print('[simulation start]') print('[simulation start]')
city = GeometryFactory('geojson', city = GeometryFactory('geojson',
@ -33,14 +36,37 @@ energy_plus_workflow(city)
city_buildings_peak_heating_demands = {} city_buildings_peak_heating_demands = {}
for building in city.buildings: for building in city.buildings:
city_buildings_peak_heating_demands[f'{building.name}'] = building.heating_peak_load[cte.YEAR] city_buildings_peak_heating_demands[f'{building.name}'] = building.heating_peak_load[cte.YEAR]
call_random(city.buildings, residential_systems_percentage) # call_random(city.buildings, residential_systems_percentage)
EnergySystemsFactory('montreal_custom', city).enrich() # EnergySystemsFactory('montreal_custom', city).enrich()
for building in city.buildings: # csv_file_path = "building_consumption_data.csv"
print(building.heating_consumption[cte.YEAR]) # building_consumption_data = []
print(building.energy_systems_archetype_name) # headers = []
# for building in city.buildings:
# building_consumption_data.append(building.heating_consumption[cte.HOUR])
# building_consumption_data.append(building.cooling_consumption[cte.HOUR])
# headers.append(f'{building.name} heating consumption')
# headers.append(f'{building.name} cooling consumption')
call_random(city.buildings, residential_new_systems_percentage) call_random(city.buildings, residential_new_systems_percentage)
EnergySystemsFactory('north_america', city).enrich() EnergySystemsFactory('north_america', city).enrich()
SystemSizing(city.buildings).hvac_sizing() SystemSizing(city.buildings).hvac_sizing()
for building in city.buildings: for building in city.buildings:
SystemSimulation(building).enrich() SystemSimulation(building).enrich()
for zone in building.internal_zones:
for thermal_zone in zone.thermal_zones_from_internal_zones:
print(thermal_zone.total_floor_area)
# with open(csv_file_path, 'w', newline='') as csvfile:
# # Create a CSV writer
# csv_writer = csv.writer(csvfile)
#
# # Write the header (optional)
# csv_writer.writerow(headers)
# max_length = max(len(data) for data in building_consumption_data)
#
# # Write the data column-wise
# for i in range(max_length):
# row_data = [building_consumption_data[j][i] if i < len(building_consumption_data[j]) else "" for j in
# range(len(building_consumption_data))]
# csv_writer.writerow(row_data)
print('test') print('test')

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

View File

@ -1,52 +0,0 @@
Processing Schedule Input -- Start
found (Current Working Directory)=C:\Users\umroot\PycharmProjects\system_assignation\out_files\cold_temp schedules 175785.dat
found (Current Working Directory)=C:\Users\umroot\PycharmProjects\system_assignation\out_files\cold_temp schedules 176293.dat
found (Current Working Directory)=C:\Users\umroot\PycharmProjects\system_assignation\out_files\cold_temp schedules 182393.dat
Processing Schedule Input -- Complete
MonthlyInputCount= 2
sizeMonthlyInput= 25
MonthlyFieldSetInputCount= 20
sizeMonthlyFieldSetInput= 50
MonthlyTablesCount= 0
MonthlyColumnsCount= 0
sizeReportName= 100
numReportName= 17
sizeSubTable= 100
numSubTable= 79
sizeColumnTag= 800
numColumnTag= 618
sizeTableEntry= 3200
numTableEntry= 1957
sizeCompSizeTableEntry= 0
numCompSizeTableEntry= 0
NumOfRVariable= 4420
NumOfRVariable(Total)= 4420
NumOfRVariable(Actual)= 45
NumOfRVariable(Summed)= 36
NumOfRVariable(Meter)= 36
NumOfIVariable= 317
NumOfIVariable(Total)= 317
NumOfIVariable(Actual)= 0
NumOfIVariable(Summed)= 0
MaxRVariable= 1000
MaxIVariable= 10
NumEnergyMeters= 78
NumVarMeterArrays= 36
maxUniqueKeyCount= 1500
maxNumberOfFigures= 3
MAXHCArrayBounds= 14
MaxVerticesPerSurface= 6
NumReportList= 500
InstMeterCacheSize= 1000
ClippingAlgorithm=SutherlandHodgman
MonthlyFieldSetInputCount= 20
NumConsideredOutputVariables= 5
MaxConsideredOutputVariables= 10000
numActuatorsUsed= 0
numEMSActuatorsAvailable= 0
maxEMSActuatorsAvailable= 0
numInternalVariablesUsed= 0
numEMSInternalVarsAvailable= 0
maxEMSInternalVarsAvailable= 0
NumOfNodeConnections= 12
MaxNumOfNodeConnections= 1000

View File

@ -1,135 +0,0 @@
Program Version,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11
! This file shows details about the branches, nodes, and other
! elements of the flow connections.
! This file is intended for use in "debugging" potential problems
! that may also be detected by the program, but may be more easily
! identified by "eye".
! This file is also intended to support software which draws a
! schematic diagram of the HVAC system.
! ===============================================================
! #Nodes,<Number of Unique Nodes>
#Nodes,9
! <Node>,<NodeNumber>,<Node Name>,<Node Fluid Type>,<# Times Node Referenced After Definition>
Node,1,175785 ZONE AIR NODE,Air,0
Node,2,175785 IDEAL LOADS SUPPLY INLET,Air,1
Node,3,175785 RETURN OUTLET,Air,0
Node,4,176293 ZONE AIR NODE,Air,0
Node,5,176293 IDEAL LOADS SUPPLY INLET,Air,1
Node,6,176293 RETURN OUTLET,Air,0
Node,7,182393 ZONE AIR NODE,Air,0
Node,8,182393 IDEAL LOADS SUPPLY INLET,Air,1
Node,9,182393 RETURN OUTLET,Air,0
! ===============================================================
! Suspicious nodes have 0 references. It is normal for some nodes, however.
! Listing nodes with 0 references (culled from previous list):
! <Suspicious Node>,<NodeNumber>,<Node Name>,<Node Fluid Type>,<# Times Node Referenced After Definition>
Suspicious Node,1,175785 ZONE AIR NODE,Air,0
Suspicious Node,3,175785 RETURN OUTLET,Air,0
Suspicious Node,4,176293 ZONE AIR NODE,Air,0
Suspicious Node,6,176293 RETURN OUTLET,Air,0
Suspicious Node,7,182393 ZONE AIR NODE,Air,0
Suspicious Node,9,182393 RETURN OUTLET,Air,0
! ===============================================================
! <#Branch Lists>,<Number of Branch Lists>
#Branch Lists,0
! <Branch List>,<Branch List Count>,<Branch List Name>,<Loop Name>,<Loop Type>,<Number of Branches>
! <Branch>,<Branch Count>,<Branch Name>,<Loop Name>,<Loop Type>,<Branch Inlet Node Name>,<Branch Outlet Node Name>
! ===============================================================
! <#Supply Air Paths>,<Number of Supply Air Paths>
#Supply Air Paths,0
! <Supply Air Path>,<Supply Air Path Count>,<Supply Air Path Name>,<AirLoopHVAC Name>
! <#Components on Supply Air Path>,<Number of Components>
! <Supply Air Path Component>,<Component Count>,<Component Type>,<Component Name>,<AirLoopHVAC Name>
! <#Outlet Nodes on Supply Air Path Component>,<Number of Nodes>
! <Supply Air Path Component Nodes>,<Node Count>,<Component Type>,<Component Name>,<Inlet Node Name>,<Outlet Node Name>,<AirLoopHVAC Name>
! ===============================================================
! <#Return Air Paths>,<Number of Return Air Paths>
#Return Air Paths,0
! <Return Air Path>,<Return Air Path Count>,<Return Air Path Name>,<AirLoopHVAC Name>
! <#Components on Return Air Path>,<Number of Components>
! <Return Air Path Component>,<Component Count>,<Component Type>,<Component Name>,<AirLoopHVAC Name>
! <#Inlet Nodes on Return Air Path Component>,<Number of Nodes>
! <Return Air Path Component Nodes>,<Node Count>,<Component Type>,<Component Name>,<Inlet Node Name>,<Outlet Node Name>,<AirLoopHVAC Name>
! ===============================================================
! #Outdoor Air Nodes,<Number of Outdoor Air Nodes>
#Outdoor Air Nodes,0
! ===============================================================
! <#Component Sets>,<Number of Component Sets>
#Component Sets,0
! <Component Set>,<Component Set Count>,<Parent Object Type>,<Parent Object Name>,<Component Type>,<Component Name>,<Inlet Node ID>,<Outlet Node ID>,<Description>
! ===============================================================
! <# Plant Loops>,<Number of Plant Loops>
#Plant Loops,0
! <Plant Loop>,<Plant Loop Name>,<Loop Type>,<Inlet Node Name>,<Outlet Node Name>,<Branch List>,<Connector List>
! <Plant Loop Connector>,<Connector Type>,<Connector Name>,<Loop Name>,<Loop Type>,<Number of Inlets/Outlets>
! <Plant Loop Connector Branches>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Branch>,<Outlet Branch>,<Loop Name>,<Loop Type>
! <Plant Loop Connector Nodes>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Node>,<Outlet Node>,<Loop Name>,<Loop Type>
! <Plant Loop Supply Connection>,<Plant Loop Name>,<Supply Side Outlet Node Name>,<Demand Side Inlet Node Name>
! <Plant Loop Return Connection>,<Plant Loop Name>,<Demand Side Outlet Node Name>,<Supply Side Inlet Node Name>
! ===============================================================
! <# Condenser Loops>,<Number of Condenser Loops>
#Condenser Loops,0
! <Condenser Loop>,<Condenser Loop Name>,<Loop Type>,<Inlet Node Name>,<Outlet Node Name>,<Branch List>,<Connector List>
! <Condenser Loop Connector>,<Connector Type>,<Connector Name>,<Loop Name>,<Loop Type>,<Number of Inlets/Outlets>
! <Condenser Loop Connector Branches>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Branch>,<Outlet Branch>,<Loop Name>,<Loop Type>
! <Condenser Loop Connector Nodes>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Node>,<Outlet Node>,<Loop Name>,<Loop Type>
! <Condenser Loop Supply Connection>,<Condenser Loop Name>,<Supply Side Outlet Node Name>,<Demand Side Inlet Node Name>
! <Condenser Loop Return Connection>,<Condenser Loop Name>,<Demand Side Outlet Node Name>,<Supply Side Inlet Node Name>
! ===============================================================
! <# Controlled Zones>,<Number of Controlled Zones>
#Controlled Zones,3
! <Controlled Zone>,<Controlled Zone Name>,<Equip List Name>,<Control List Name>,<Zone Node Name>,<# Inlet Nodes>,<# Exhaust Nodes>,<# Return Nodes>
! <Controlled Zone Inlet>,<Inlet Node Count>,<Controlled Zone Name>,<Supply Air Inlet Node Name>,<SD Sys:Cooling/Heating [DD:Cooling] Inlet Node Name>,<DD Sys:Heating Inlet Node Name>
! <Controlled Zone Exhaust>,<Exhaust Node Count>,<Controlled Zone Name>,<Exhaust Air Node Name>
Controlled Zone,175785,175785 EQUIPMENT,,175785 ZONE AIR NODE,1,0,1
Controlled Zone Inlet,1,175785,175785 IDEAL LOADS SUPPLY INLET,Undefined,N/A
Controlled Zone Return,1,175785,175785 RETURN OUTLET
Controlled Zone,176293,176293 EQUIPMENT,,176293 ZONE AIR NODE,1,0,1
Controlled Zone Inlet,1,176293,176293 IDEAL LOADS SUPPLY INLET,Undefined,N/A
Controlled Zone Return,1,176293,176293 RETURN OUTLET
Controlled Zone,182393,182393 EQUIPMENT,,182393 ZONE AIR NODE,1,0,1
Controlled Zone Inlet,1,182393,182393 IDEAL LOADS SUPPLY INLET,Undefined,N/A
Controlled Zone Return,1,182393,182393 RETURN OUTLET
! ===============================================================
! <#Zone Equipment Lists>,<Number of Zone Equipment Lists>
#Zone Equipment Lists,3
! <Zone Equipment List>,<Zone Equipment List Count>,<Zone Equipment List Name>,<Zone Name>,<Number of Components>
! <Zone Equipment Component>,<Component Count>,<Component Type>,<Component Name>,<Zone Name>,<Heating Priority>,<Cooling Priority>
Zone Equipment List,1,175785 EQUIPMENT,175785,1
Zone Equipment Component,1,ZONEHVAC:IDEALLOADSAIRSYSTEM,175785 IDEAL LOADS AIR SYSTEM,175785,1,1
Zone Equipment List,2,176293 EQUIPMENT,176293,1
Zone Equipment Component,1,ZONEHVAC:IDEALLOADSAIRSYSTEM,176293 IDEAL LOADS AIR SYSTEM,176293,1,1
Zone Equipment List,3,182393 EQUIPMENT,182393,1
Zone Equipment Component,1,ZONEHVAC:IDEALLOADSAIRSYSTEM,182393 IDEAL LOADS AIR SYSTEM,182393,1,1
! ===============================================================
! <#AirLoopHVACs>,<Number of AirLoopHVACs>
#AirLoopHVACs,0
! <AirLoopHVAC>,<Air Loop Name>,<# Return Nodes>,<# Supply Nodes>,<# Zones Cooled>,<# Zones Heated>,<Outdoor Air Used>
! <AirLoop Return Connections>,<Connection Count>,<AirLoopHVAC Name>,<Zn Eqp Return Node #>,<Zn Eqp Return Node Name>,<AirLoop Return Node #>,<Air Loop Return Node Name>
! <AirLoop Supply Connections>,<Connection Count>,<AirLoopHVAC Name>,<Zn Eqp Supply Node #>,<Zn Eqp Supply Node Name>,<AirLoop Supply Node #>,<Air Loop Supply Node Name>
! <Cooled Zone Info>,<Cooled Zone Count>,<Cooled Zone Name>,<Cooled Zone Inlet Node #>,<Cooled Zone Inlet Node Name>,<AirLoopHVAC Name>
! <Heated Zone Info>,<Heated Zone Count>,<Heated Zone Name>,<Heated Zone Inlet Node #>,<Heated Zone Inlet Node Name>,<AirLoopHVAC Name>
! <Outdoor Air Connections>,<OA Inlet Node #>,<OA Return Air Inlet Node Name>,<OA Outlet Node #>,<OA Mixed Air Outlet Node Name>,<AirLoopHVAC Name>
! <AirLoopHVAC Connector>,<Connector Type>,<Connector Name>,<Loop Name>,<Loop Type>,<Number of Inlets/Outlets>
! <AirLoopHVAC Connector Branches>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Branch>,<Outlet Branch>,<Loop Name>,<Loop Type>
! <AirLoopHVAC Connector Nodes>,<Connector Node Count>,<Connector Type>,<Connector Name>,<Inlet Node>,<Outlet Node>,<Loop Name>,<Loop Type>
! ===============================================================
! <#Parent Node Connections>,<Number of Parent Node Connections>
#Parent Node Connections,0
! <Parent Node Connection>,<Node Name>,<Node ObjectType>,<Node ObjectName>,<Node ConnectionType>,<Node FluidStream>
! ===============================================================
! <#Non-Parent Node Connections>,<Number of Non-Parent Node Connections>
#Non-Parent Node Connections,12
! <Non-Parent Node Connection>,<Node Name>,<Node ObjectType>,<Node ObjectName>,<Node ConnectionType>,<Node FluidStream>
Non-Parent Node Connection,175785 ZONE AIR NODE,ZONEHVAC:EQUIPMENTCONNECTIONS,175785,ZoneNode,1
Non-Parent Node Connection,175785 IDEAL LOADS SUPPLY INLET,ZONEHVAC:EQUIPMENTCONNECTIONS,175785,ZoneInlet,1
Non-Parent Node Connection,175785 RETURN OUTLET,ZONEHVAC:EQUIPMENTCONNECTIONS,175785,ZoneReturn,1
Non-Parent Node Connection,176293 ZONE AIR NODE,ZONEHVAC:EQUIPMENTCONNECTIONS,176293,ZoneNode,1
Non-Parent Node Connection,176293 IDEAL LOADS SUPPLY INLET,ZONEHVAC:EQUIPMENTCONNECTIONS,176293,ZoneInlet,1
Non-Parent Node Connection,176293 RETURN OUTLET,ZONEHVAC:EQUIPMENTCONNECTIONS,176293,ZoneReturn,1
Non-Parent Node Connection,182393 ZONE AIR NODE,ZONEHVAC:EQUIPMENTCONNECTIONS,182393,ZoneNode,1
Non-Parent Node Connection,182393 IDEAL LOADS SUPPLY INLET,ZONEHVAC:EQUIPMENTCONNECTIONS,182393,ZoneInlet,1
Non-Parent Node Connection,182393 RETURN OUTLET,ZONEHVAC:EQUIPMENTCONNECTIONS,182393,ZoneReturn,1
Non-Parent Node Connection,175785 IDEAL LOADS SUPPLY INLET,ZONEHVAC:IDEALLOADSAIRSYSTEM,175785 IDEAL LOADS AIR SYSTEM,Outlet,1
Non-Parent Node Connection,176293 IDEAL LOADS SUPPLY INLET,ZONEHVAC:IDEALLOADSAIRSYSTEM,176293 IDEAL LOADS AIR SYSTEM,Outlet,1
Non-Parent Node Connection,182393 IDEAL LOADS SUPPLY INLET,ZONEHVAC:IDEALLOADSAIRSYSTEM,182393 IDEAL LOADS AIR SYSTEM,Outlet,1

File diff suppressed because it is too large Load Diff

View File

@ -1,117 +0,0 @@
Program Version,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11
! <Version>, Version ID
Version, 9.5
! <Timesteps per Hour>, #TimeSteps, Minutes per TimeStep {minutes}
Timesteps per Hour, 4, 15
! <System Convergence Limits>, Minimum System TimeStep {minutes}, Max HVAC Iterations, Minimum Plant Iterations, Maximum Plant Iterations
System Convergence Limits, 1, 20, 2, 8
! <Simulation Control>, Do Zone Sizing, Do System Sizing, Do Plant Sizing, Do Design Days, Do Weather Simulation, Do HVAC Sizing Simulation
Simulation Control, No, No, No, No, Yes, No
! <Performance Precision Tradeoffs>, Use Coil Direct Simulation, Zone Radiant Exchange Algorithm, Override Mode, Number of Timestep In Hour, Force Euler Method, Minimum Number of Warmup Days, Force Suppress All Begin Environment Resets, Minimum System Timestep, MaxZoneTempDiff, MaxAllowedDelTemp
Performance Precision Tradeoffs, No, ScriptF, Normal, 4, No, 1, No, 1.0, 0.300, 2.0000E-003
! <Output Reporting Tolerances>, Tolerance for Time Heating Setpoint Not Met, Tolerance for Zone Cooling Setpoint Not Met Time
Output Reporting Tolerances, 0.200, 0.200,
! <Site:GroundTemperature:BuildingSurface>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
Site:GroundTemperature:BuildingSurface, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00
! <Site:GroundTemperature:FCfactorMethod>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
Site:GroundTemperature:FCfactorMethod, -1.50, -6.19, -7.46, -6.35, -0.03, 7.05, 13.71, 18.53, 19.94, 17.67, 12.21, 5.33
! <Site:GroundTemperature:Shallow>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
Site:GroundTemperature:Shallow, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00
! <Site:GroundTemperature:Deep>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
Site:GroundTemperature:Deep, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00
! <Site:GroundReflectance>,Jan{dimensionless},Feb{dimensionless},Mar{dimensionless},Apr{dimensionless},May{dimensionless},Jun{dimensionless},Jul{dimensionless},Aug{dimensionless},Sep{dimensionless},Oct{dimensionless},Nov{dimensionless},Dec{dimensionless}
Site:GroundReflectance, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20
! <Site:GroundReflectance:SnowModifier>, Normal, Daylighting {dimensionless}
Site:GroundReflectance:SnowModifier, 1.000, 1.000
! <Site:GroundReflectance:Snow>,Jan{dimensionless},Feb{dimensionless},Mar{dimensionless},Apr{dimensionless},May{dimensionless},Jun{dimensionless},Jul{dimensionless},Aug{dimensionless},Sep{dimensionless},Oct{dimensionless},Nov{dimensionless},Dec{dimensionless}
Site:GroundReflectance:Snow, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20
! <Site:GroundReflectance:Snow:Daylighting>,Jan{dimensionless},Feb{dimensionless},Mar{dimensionless},Apr{dimensionless},May{dimensionless},Jun{dimensionless},Jul{dimensionless},Aug{dimensionless},Sep{dimensionless},Oct{dimensionless},Nov{dimensionless},Dec{dimensionless}
Site:GroundReflectance:Snow:Daylighting, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20
! <Environment:Weather Station>,Wind Sensor Height Above Ground {m},Wind Speed Profile Exponent {},Wind Speed Profile Boundary Layer Thickness {m},Air Temperature Sensor Height Above Ground {m},Wind Speed Modifier Coefficient-Internal,Temperature Modifier Coefficient-Internal
Environment:Weather Station,10.000,0.140,270.000,1.500,1.586,9.750E-003
! <Site:Location>, Location Name, Latitude {N+/S- Deg}, Longitude {E+/W- Deg}, Time Zone Number {GMT+/-}, Elevation {m}, Standard Pressure at Elevation {Pa}, Standard RhoAir at Elevation
Site:Location,Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270,45.47,-73.75,-5.00,36.00,100893,1.1992
! <Site Water Mains Temperature Information>,Calculation Method{},Water Mains Temperature Schedule Name{},Annual Average Outdoor Air Temperature{C},Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC},Fixed Default Water Mains Temperature{C}
Site Water Mains Temperature Information,FixedDefault,NA,NA,NA,10.0
! <Building Information>, Building Name,North Axis {deg},Terrain, Loads Convergence Tolerance Value,Temperature Convergence Tolerance Value, Solar Distribution,Maximum Number of Warmup Days,Minimum Number of Warmup Days
Building Information,Buildings in b'Montreal',0.000,Suburbs,4.00000E-002,0.40000,FullExterior,25,6
! <Inside Convection Algorithm>, Algorithm {Simple | TARP | CeilingDiffuser | AdaptiveConvectionAlgorithm}
Inside Convection Algorithm,TARP
! <Outside Convection Algorithm>, Algorithm {SimpleCombined | TARP | MoWitt | DOE-2 | AdaptiveConvectionAlgorithm}
Outside Convection Algorithm,DOE-2
! <Sky Radiance Distribution>, Value {Anisotropic}
Sky Radiance Distribution,Anisotropic
! <Zone Air Solution Algorithm>, Value {ThirdOrderBackwardDifference | AnalyticalSolution | EulerMethod}
Zone Air Solution Algorithm, ThirdOrderBackwardDifference
! <Zone Air Carbon Dioxide Balance Simulation>, Simulation {Yes/No}, Carbon Dioxide Concentration
Zone Air Carbon Dioxide Balance Simulation, No,N/A
! <Zone Air Generic Contaminant Balance Simulation>, Simulation {Yes/No}, Generic Contaminant Concentration
Zone Air Generic Contaminant Balance Simulation, No,N/A
! <Zone Air Mass Flow Balance Simulation>, Enforce Mass Balance, Adjust Zone Mixing and Return {AdjustMixingOnly | AdjustReturnOnly | AdjustMixingThenReturn | AdjustReturnThenMixing | None}, Adjust Zone Infiltration {AddInfiltration | AdjustInfiltration | None}, Infiltration Zones {MixingSourceZonesOnly | AllZones}
Zone Air Mass Flow Balance Simulation, No,N/A,N/A,N/A
! <HVACSystemRootFindingAlgorithm>, Value {RegulaFalsi | Bisection | BisectionThenRegulaFalsi | RegulaFalsiThenBisection}
HVACSystemRootFindingAlgorithm, RegulaFalsi
! <Environment:Site Atmospheric Variation>,Wind Speed Profile Exponent {},Wind Speed Profile Boundary Layer Thickness {m},Air Temperature Gradient Coefficient {K/m}
Environment:Site Atmospheric Variation,0.220,370.000,6.500000E-003
! <Surface Geometry>,Starting Corner,Vertex Input Direction,Coordinate System,Daylight Reference Point Coordinate System,Rectangular (Simple) Surface Coordinate System
Surface Geometry,UpperLeftCorner,Counterclockwise,WorldCoordinateSystem,RelativeCoordinateSystem,RelativeToZoneOrigin
! <Surface Heat Transfer Algorithm>, Value {CTF - ConductionTransferFunction | EMPD - MoisturePenetrationDepthConductionTransferFunction | CondFD - ConductionFiniteDifference | HAMT - CombinedHeatAndMoistureFiniteElement} - Description,Inside Surface Max Temperature Limit{C}, Surface Convection Coefficient Lower Limit {W/m2-K}, Surface Convection Coefficient Upper Limit {W/m2-K}
Surface Heat Transfer Algorithm, CTF - ConductionTransferFunction,200,0.10,1000.0
! <Shading Summary>, Number of Fixed Detached Shades, Number of Building Detached Shades, Number of Attached Shades
Shading Summary,0,0,0
! <Zone Summary>, Number of Zones, Number of Zone Surfaces, Number of SubSurfaces
Zone Summary,3,36,14
! <Zone Information>,Zone Name,North Axis {deg},Origin X-Coordinate {m},Origin Y-Coordinate {m},Origin Z-Coordinate {m},Centroid X-Coordinate {m},Centroid Y-Coordinate {m},Centroid Z-Coordinate {m},Type,Zone Multiplier,Zone List Multiplier,Minimum X {m},Maximum X {m},Minimum Y {m},Maximum Y {m},Minimum Z {m},Maximum Z {m},Ceiling Height {m},Volume {m3},Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall},Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST}, Floor Area {m2},Exterior Gross Wall Area {m2},Exterior Net Wall Area {m2},Exterior Window Area {m2}, Number of Surfaces, Number of SubSurfaces, Number of Shading SubSurfaces, Part of Total Building Area
Zone Information, 175785,0.0,0.00,0.00,0.00,8.32,14.89,6.00,1,1,1,0.00,17.71,11.28,17.93,0.00,12.00,12.00,1403.17,TARP,DOE-2,116.93,410.07,328.14,81.93,8,5,0,Yes
Zone Information, 176293,0.0,0.00,0.00,0.00,10.46,21.10,6.00,1,1,1,3.21,17.70,17.89,24.31,0.00,12.00,12.00,1109.06,TARP,DOE-2,92.42,326.92,261.60,65.32,6,3,0,Yes
Zone Information, 182393,0.0,0.00,0.00,0.00,10.54,3.91,4.00,1,1,1,3.38,17.71,0.00,7.27,0.00,8.00,8.00,797.48,TARP,DOE-2,99.69,340.41,272.39,68.01,8,6,0,Yes
! <Zone Internal Gains Nominal>,Zone Name, Floor Area {m2},# Occupants,Area per Occupant {m2/person},Occupant per Area {person/m2},Interior Lighting {W/m2},Electric Load {W/m2},Gas Load {W/m2},Other Load {W/m2},Hot Water Eq {W/m2},Steam Equipment {W/m2},Sum Loads per Area {W/m2},Outdoor Controlled Baseboard Heat
Zone Internal Gains Nominal, 175785,116.93,18.7,6.248,0.160,22.008,0.000,0.000,20.007,0.000,0.000,42.015,No
Zone Internal Gains Nominal, 176293,92.42,14.8,6.248,0.160,22.008,0.000,0.000,20.007,0.000,0.000,42.015,No
Zone Internal Gains Nominal, 182393,99.69,8.0,12.495,8.003E-002,11.004,0.000,0.000,10.004,0.000,0.000,21.008,No
! <People Internal Gains Nominal>,Name,Schedule Name,Zone Name,Zone Floor Area {m2},# Zone Occupants,Number of People {},People/Floor Area {person/m2},Floor Area per person {m2/person},Fraction Radiant,Fraction Convected,Sensible Fraction Calculation,Activity level,ASHRAE 55 Warnings,Carbon Dioxide Generation Rate,Nominal Minimum Number of People,Nominal Maximum Number of People
People Internal Gains Nominal, 175785_OCCUPANCY,OCCUPANCY SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,175785,116.93,18.7,18.7,0.160,6.248,0.100,0.900,AutoCalculate,ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,No,3.8200E-008,0,17
People Internal Gains Nominal, 176293_OCCUPANCY,OCCUPANCY SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,176293,92.42,14.8,14.8,0.160,6.248,0.100,0.900,AutoCalculate,ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,No,3.8200E-008,0,13
People Internal Gains Nominal, 182393_OCCUPANCY,OCCUPANCY SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,182393,99.69,8.0,8.0,8.003E-002,12.495,0.100,0.900,AutoCalculate,ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,No,3.8200E-008,0,7
! <Lights Internal Gains Nominal>,Name,Schedule Name,Zone Name,Zone Floor Area {m2},# Zone Occupants,Lighting Level {W},Lights/Floor Area {W/m2},Lights per person {W/person},Fraction Return Air,Fraction Radiant,Fraction Short Wave,Fraction Convected,Fraction Replaceable,End-Use Category,Nominal Minimum Lighting Level {W},Nominal Maximum Lighting Level {W}
Lights Internal Gains Nominal, 175785_LIGHTS,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,175785,116.93,18.7,2573.415,22.008,137.500,0.000,0.500,0.000,0.500,1.000,ELECTRIC EQUIPMENT#175785#GeneralLights,0.000,2316.074
Lights Internal Gains Nominal, 176293_LIGHTS,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,176293,92.42,14.8,2034.020,22.008,137.500,0.000,0.500,0.000,0.500,1.000,ELECTRIC EQUIPMENT#176293#GeneralLights,0.000,1830.618
Lights Internal Gains Nominal, 182393_LIGHTS,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,182393,99.69,8.0,1096.936,11.004,137.500,0.000,0.500,0.000,0.500,1.000,ELECTRIC EQUIPMENT#182393#GeneralLights,0.000,987.243
! <OtherEquipment Internal Gains Nominal>,Name,Schedule Name,Zone Name,Zone Floor Area {m2},# Zone Occupants,Equipment Level {W},Equipment/Floor Area {W/m2},Equipment per person {W/person},Fraction Latent,Fraction Radiant,Fraction Lost,Fraction Convected,Nominal Minimum Equipment Level {W},Nominal Maximum Equipment Level {W}
OtherEquipment Internal Gains Nominal, 175785_APPLIANCE,APPLIANCE SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,175785,116.93,18.7,2339.468,20.007,125.000,0.000,0.500,0.000,0.500,0.000,2105.522
OtherEquipment Internal Gains Nominal, 176293_APPLIANCE,APPLIANCE SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,176293,92.42,14.8,1849.109,20.007,125.000,0.000,0.500,0.000,0.500,0.000,1664.198
OtherEquipment Internal Gains Nominal, 182393_APPLIANCE,APPLIANCE SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,182393,99.69,8.0,997.215,10.004,125.000,0.000,0.500,0.000,0.500,0.000,897.493
! <Shadowing/Sun Position Calculations Annual Simulations>, Shading Calculation Method, Shading Calculation Update Frequency Method, Shading Calculation Update Frequency {days}, Maximum Figures in Shadow Overlap Calculations {}, Polygon Clipping Algorithm, Pixel Counting Resolution, Sky Diffuse Modeling Algorithm, Output External Shading Calculation Results, Disable Self-Shading Within Shading Zone Groups, Disable Self-Shading From Shading Zone Groups to Other Zones
Shadowing/Sun Position Calculations Annual Simulations,PolygonClipping,Periodic,20,15000,SutherlandHodgman,512,SimpleSkyDiffuseModeling,No,No,No
! <ZoneInfiltration Airflow Stats Nominal>,Name,Schedule Name,Zone Name, Zone Floor Area {m2}, # Zone Occupants,Design Volume Flow Rate {m3/s},Volume Flow Rate/Floor Area {m3/s-m2},Volume Flow Rate/Exterior Surface Area {m3/s-m2},ACH - Air Changes per Hour,Equation A - Constant Term Coefficient {},Equation B - Temperature Term Coefficient {1/C},Equation C - Velocity Term Coefficient {s/m}, Equation D - Velocity Squared Term Coefficient {s2/m2}
ZoneInfiltration Airflow Stats Nominal, 175785_INFILTRATION,INFILTRATION SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,175785,116.93,18.7,0.242,2.067E-003,4.586E-004,0.620,1.000,0.000,0.000,0.000
ZoneInfiltration Airflow Stats Nominal, 176293_INFILTRATION,INFILTRATION SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,176293,92.42,14.8,0.191,2.067E-003,4.555E-004,0.620,1.000,0.000,0.000,0.000
ZoneInfiltration Airflow Stats Nominal, 182393_INFILTRATION,INFILTRATION SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,182393,99.69,8.0,0.137,1.378E-003,3.121E-004,0.620,1.000,0.000,0.000,0.000
! <ZoneVentilation Airflow Stats Nominal>,Name,Schedule Name,Zone Name, Zone Floor Area {m2}, # Zone Occupants,Design Volume Flow Rate {m3/s},Volume Flow Rate/Floor Area {m3/s-m2},Volume Flow Rate/person Area {m3/s-person},ACH - Air Changes per Hour,Fan Type {Exhaust;Intake;Natural},Fan Pressure Rise {Pa},Fan Efficiency {},Equation A - Constant Term Coefficient {},Equation B - Temperature Term Coefficient {1/C},Equation C - Velocity Term Coefficient {s/m}, Equation D - Velocity Squared Term Coefficient {s2/m2},Minimum Indoor Temperature{C}/Schedule,Maximum Indoor Temperature{C}/Schedule,Delta Temperature{C}/Schedule,Minimum Outdoor Temperature{C}/Schedule,Maximum Outdoor Temperature{C}/Schedule,Maximum WindSpeed{m/s}
ZoneVentilation Airflow Stats Nominal, 175785_VENTILATION,VENTILATION SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,175785,116.93,18.7,0.143,1.219E-003,7.617E-003,0.366,Natural,0.000,1.0,1.000,0.000,0.000,0.000,-100.00,100.00,-100.00,-100.00,100.00,40.00
ZoneVentilation Airflow Stats Nominal, 176293_VENTILATION,VENTILATION SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,176293,92.42,14.8,0.113,1.219E-003,7.617E-003,0.366,Natural,0.000,1.0,1.000,0.000,0.000,0.000,-100.00,100.00,-100.00,-100.00,100.00,40.00
ZoneVentilation Airflow Stats Nominal, 182393_VENTILATION,VENTILATION SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,182393,99.69,8.0,6.077E-002,6.096E-004,7.617E-003,0.274,Natural,0.000,1.0,1.000,0.000,0.000,0.000,-100.00,100.00,-100.00,-100.00,100.00,40.00
! <AirFlow Model>, Simple
AirFlow Model, Simple
! <RoomAir Model>, Zone Name, Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
RoomAir Model,175785,Mixing/Well-Stirred
RoomAir Model,176293,Mixing/Well-Stirred
RoomAir Model,182393,Mixing/Well-Stirred
! <AirflowNetwork Model:Control>, No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
AirflowNetwork Model:Control,NoMultizoneOrDistribution
! <Zone Volume Capacitance Multiplier>, Sensible Heat Capacity Multiplier, Moisture Capacity Multiplier, Carbon Dioxide Capacity Multiplier, Generic Contaminant Capacity Multiplier
Zone Volume Capacitance Multiplier, 1.000 , 1.000, 1.000, 1.000
! <Environment>,Environment Name,Environment Type, Start Date, End Date, Start DayOfWeek, Duration {#days}, Source:Start DayOfWeek, Use Daylight Saving, Use Holidays, Apply Weekend Holiday Rule, Use Rain Values, Use Snow Values, Sky Temperature Model
! <Environment:Special Days>, Special Day Name, Special Day Type, Source, Start Date, Duration {#days}
! <Environment:Daylight Saving>, Daylight Saving Indicator, Source, Start Date, End Date
! <Environment:WarmupDays>, NumberofWarmupDays
Environment,RUN PERIOD 1,WeatherFileRunPeriod,01/01/2013,12/31/2013,Tuesday,365,Use RunPeriod Specified Day,Yes,Yes,No,Yes,Yes,Clark and Allen
Environment:Daylight Saving,No,
Environment:WarmupDays, 6
! <Warmup Convergence Information>,Zone Name,Environment Type/Name,Average Warmup Temperature Difference {deltaC},Std Dev Warmup Temperature Difference {deltaC},Max Temperature Pass/Fail Convergence,Min Temperature Pass/Fail Convergence,Average Warmup Load Difference {W},Std Dev Warmup Load Difference {W},Heating Load Pass/Fail Convergence,Cooling Load Pass/Fail Convergence
Warmup Convergence Information,175785,RunPeriod: RUN PERIOD 1,9.3824972476E-002,0.4154526533,Pass,Pass,0.1433381723,0.3290892348,Pass,Pass
Warmup Convergence Information,176293,RunPeriod: RUN PERIOD 1,9.1898016321E-002,0.4123345602,Pass,Pass,0.1278317775,0.3389104038,Pass,Pass
Warmup Convergence Information,182393,RunPeriod: RUN PERIOD 1,9.1565697069E-002,0.4152215081,Pass,Pass,0.3493153409,1.4374670798,Pass,Pass
! <Program Control Information:Threads/Parallel Sims>, Threading Supported,Maximum Number of Threads, Env Set Threads (OMP_NUM_THREADS), EP Env Set Threads (EP_OMP_NUM_THREADS), IDF Set Threads, Number of Threads Used (Interior Radiant Exchange), Number Nominal Surfaces, Number Parallel Sims
Program Control:Threads/Parallel Sims, No,1, N/A, N/A, N/A, N/A, N/A, N/A
End of Data

View File

@ -1 +0,0 @@
EnergyPlus Completed Successfully-- 26 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 6.36sec

View File

@ -1,56 +0,0 @@
Program Version,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11,
** Warning ** GetHTSurfaceData: Surfaces with interface to Ground found but no "Ground Temperatures" were input.
** ~~~ ** Found first in surface=6ACF7617-7D20-4059-916F-A322696BF7D6
** ~~~ ** Defaults, constant throughout the year of (18.0) will be used.
** Warning ** GetInternalHeatGains: People="175785_OCCUPANCY", Activity Level Schedule Name values
** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.
** ~~~ ** Odd comfort values may result; Schedule="ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING".
** ~~~ ** Entered min/max range=[0.0,] W/person.146.5
** Warning ** GetInternalHeatGains: People="176293_OCCUPANCY", Activity Level Schedule Name values
** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.
** ~~~ ** Odd comfort values may result; Schedule="ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING".
** ~~~ ** Entered min/max range=[0.0,] W/person.146.5
** Warning ** GetInternalHeatGains: People="182393_OCCUPANCY", Activity Level Schedule Name values
** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.
** ~~~ ** Odd comfort values may result; Schedule="ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING".
** ~~~ ** Entered min/max range=[0.0,] W/person.146.5
** Warning ** DetermineShadowingCombinations: There are 1 surfaces which are receiving surfaces and are non-convex.
** ~~~ ** ...Shadowing values may be inaccurate. Check .shd report file for more surface shading details
** ~~~ ** ...Add Output:Diagnostics,DisplayExtraWarnings; to see individual warnings for each surface.
************* Testing Individual Branch Integrity
************* All Branches passed integrity testing
************* Testing Individual Supply Air Path Integrity
************* All Supply Air Paths passed integrity testing
************* Testing Individual Return Air Path Integrity
************* All Return Air Paths passed integrity testing
************* No node connection errors were found.
************* Beginning Simulation
** Severe ** Output:Table:SummaryReports Field[6]="STANDARD62.1SUMMARY", invalid report name -- will not be reported.
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL1'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL2'
** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL2'
** Warning ** Processing Monthly Tabular Reports: Variable names not valid for this simulation
** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual variables.
************* Simulation Error Summary *************
************* There are 1 unused objects in input.
************* Use Output:Diagnostics,DisplayUnusedObjects; to see them.
************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
************* EnergyPlus Completed Successfully-- 26 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 6.36sec

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

View File

@ -1,564 +0,0 @@
Meters for 7,175785_LIGHTS:Lights Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:175785 [J]
OnMeter=InteriorLights:Electricity [J]
OnMeter=InteriorLights:Electricity:Zone:175785 [J]
OnMeter=ELECTRIC EQUIPMENT#175785#GeneralLights:InteriorLights:Electricity [J]
Meters for 81,176293_LIGHTS:Lights Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:176293 [J]
OnMeter=InteriorLights:Electricity [J]
OnMeter=InteriorLights:Electricity:Zone:176293 [J]
OnMeter=ELECTRIC EQUIPMENT#176293#GeneralLights:InteriorLights:Electricity [J]
Meters for 119,182393_LIGHTS:Lights Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:182393 [J]
OnMeter=InteriorLights:Electricity [J]
OnMeter=InteriorLights:Electricity:Zone:182393 [J]
OnMeter=ELECTRIC EQUIPMENT#182393#GeneralLights:InteriorLights:Electricity [J]
Meters for 158,175785_APPLIANCE:Other Equipment Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:175785 [J]
OnMeter=InteriorEquipment:Electricity [J]
OnMeter=InteriorEquipment:Electricity:Zone:175785 [J]
OnMeter=ELECTRIC EQUIPMENT#175785#InteriorEquipment:InteriorEquipment:Electricity [J]
Meters for 196,176293_APPLIANCE:Other Equipment Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:176293 [J]
OnMeter=InteriorEquipment:Electricity [J]
OnMeter=InteriorEquipment:Electricity:Zone:176293 [J]
OnMeter=ELECTRIC EQUIPMENT#176293#InteriorEquipment:InteriorEquipment:Electricity [J]
Meters for 222,182393_APPLIANCE:Other Equipment Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:182393 [J]
OnMeter=InteriorEquipment:Electricity [J]
OnMeter=InteriorEquipment:Electricity:Zone:182393 [J]
OnMeter=ELECTRIC EQUIPMENT#182393#InteriorEquipment:InteriorEquipment:Electricity [J]
Meters for 247,175785:Zone Ventilation Fan Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:175785 [J]
OnMeter=Fans:Electricity [J]
OnMeter=Fans:Electricity:Zone:175785 [J]
OnMeter=Ventilation (simple):Fans:Electricity [J]
Meters for 284,176293:Zone Ventilation Fan Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:176293 [J]
OnMeter=Fans:Electricity [J]
OnMeter=Fans:Electricity:Zone:176293 [J]
OnMeter=Ventilation (simple):Fans:Electricity [J]
Meters for 297,182393:Zone Ventilation Fan Electricity Energy [J]
OnMeter=Electricity:Facility [J]
OnMeter=Electricity:Building [J]
OnMeter=Electricity:Zone:182393 [J]
OnMeter=Fans:Electricity [J]
OnMeter=Fans:Electricity:Zone:182393 [J]
OnMeter=Ventilation (simple):Fans:Electricity [J]
Meters for 310,175785:Zone Air System Sensible Heating Energy [J]
OnMeter=EnergyTransfer:Facility [J]
OnMeter=EnergyTransfer:Building [J]
OnMeter=EnergyTransfer:Zone:175785 [J]
OnMeter=Heating:EnergyTransfer [J]
OnMeter=Heating:EnergyTransfer:Zone:175785 [J]
OnMeter=General:Heating:EnergyTransfer [J]
Meters for 383,175785:Zone Air System Sensible Cooling Energy [J]
OnMeter=EnergyTransfer:Facility [J]
OnMeter=EnergyTransfer:Building [J]
OnMeter=EnergyTransfer:Zone:175785 [J]
OnMeter=Cooling:EnergyTransfer [J]
OnMeter=Cooling:EnergyTransfer:Zone:175785 [J]
OnMeter=General:Cooling:EnergyTransfer [J]
Meters for 420,176293:Zone Air System Sensible Heating Energy [J]
OnMeter=EnergyTransfer:Facility [J]
OnMeter=EnergyTransfer:Building [J]
OnMeter=EnergyTransfer:Zone:176293 [J]
OnMeter=Heating:EnergyTransfer [J]
OnMeter=Heating:EnergyTransfer:Zone:176293 [J]
OnMeter=General:Heating:EnergyTransfer [J]
Meters for 445,176293:Zone Air System Sensible Cooling Energy [J]
OnMeter=EnergyTransfer:Facility [J]
OnMeter=EnergyTransfer:Building [J]
OnMeter=EnergyTransfer:Zone:176293 [J]
OnMeter=Cooling:EnergyTransfer [J]
OnMeter=Cooling:EnergyTransfer:Zone:176293 [J]
OnMeter=General:Cooling:EnergyTransfer [J]
Meters for 458,182393:Zone Air System Sensible Heating Energy [J]
OnMeter=EnergyTransfer:Facility [J]
OnMeter=EnergyTransfer:Building [J]
OnMeter=EnergyTransfer:Zone:182393 [J]
OnMeter=Heating:EnergyTransfer [J]
OnMeter=Heating:EnergyTransfer:Zone:182393 [J]
OnMeter=General:Heating:EnergyTransfer [J]
Meters for 483,182393:Zone Air System Sensible Cooling Energy [J]
OnMeter=EnergyTransfer:Facility [J]
OnMeter=EnergyTransfer:Building [J]
OnMeter=EnergyTransfer:Zone:182393 [J]
OnMeter=Cooling:EnergyTransfer [J]
OnMeter=Cooling:EnergyTransfer:Zone:182393 [J]
OnMeter=General:Cooling:EnergyTransfer [J]
Meters for 496,175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy [J]
OnMeter=DistrictHeating:Facility [J]
OnMeter=DistrictHeating:HVAC [J]
OnMeter=Heating:DistrictHeating [J]
OnMeter=General:Heating:DistrictHeating [J]
Meters for 545,175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy [J]
OnMeter=DistrictCooling:Facility [J]
OnMeter=DistrictCooling:HVAC [J]
OnMeter=Cooling:DistrictCooling [J]
OnMeter=General:Cooling:DistrictCooling [J]
Meters for 594,176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy [J]
OnMeter=DistrictHeating:Facility [J]
OnMeter=DistrictHeating:HVAC [J]
OnMeter=Heating:DistrictHeating [J]
OnMeter=General:Heating:DistrictHeating [J]
Meters for 595,176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy [J]
OnMeter=DistrictCooling:Facility [J]
OnMeter=DistrictCooling:HVAC [J]
OnMeter=Cooling:DistrictCooling [J]
OnMeter=General:Cooling:DistrictCooling [J]
Meters for 596,182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy [J]
OnMeter=DistrictHeating:Facility [J]
OnMeter=DistrictHeating:HVAC [J]
OnMeter=Heating:DistrictHeating [J]
OnMeter=General:Heating:DistrictHeating [J]
Meters for 597,182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy [J]
OnMeter=DistrictCooling:Facility [J]
OnMeter=DistrictCooling:HVAC [J]
OnMeter=Cooling:DistrictCooling [J]
OnMeter=General:Cooling:DistrictCooling [J]
Meters for 598,DHW 175785:Water Use Equipment Total Volume [m3]
OnMeter=Water:Facility [m3]
OnMeter=Water:Plant [m3]
OnMeter=WaterSystems:Water [m3]
OnMeter=DHW 175785:WaterSystems:Water [m3]
Meters for 647,DHW 175785:Water Use Equipment Mains Water Volume [m3]
OnMeter=MainsWater:Facility [m3]
OnMeter=MainsWater:Plant [m3]
OnMeter=WaterSystems:MainsWater [m3]
OnMeter=DHW 175785:WaterSystems:MainsWater [m3]
Meters for 697,DHW 175785:Water Use Equipment Heating Energy [J]
OnMeter=DistrictHeating:Facility [J]
OnMeter=DistrictHeating:Plant [J]
OnMeter=WaterSystems:DistrictHeating [J]
OnMeter=DHW 175785:WaterSystems:DistrictHeating [J]
Meters for 734,DHW 176293:Water Use Equipment Total Volume [m3]
OnMeter=Water:Facility [m3]
OnMeter=Water:Plant [m3]
OnMeter=WaterSystems:Water [m3]
OnMeter=DHW 176293:WaterSystems:Water [m3]
Meters for 747,DHW 176293:Water Use Equipment Mains Water Volume [m3]
OnMeter=MainsWater:Facility [m3]
OnMeter=MainsWater:Plant [m3]
OnMeter=WaterSystems:MainsWater [m3]
OnMeter=DHW 176293:WaterSystems:MainsWater [m3]
Meters for 761,DHW 176293:Water Use Equipment Heating Energy [J]
OnMeter=DistrictHeating:Facility [J]
OnMeter=DistrictHeating:Plant [J]
OnMeter=WaterSystems:DistrictHeating [J]
OnMeter=DHW 176293:WaterSystems:DistrictHeating [J]
Meters for 774,DHW 182393:Water Use Equipment Total Volume [m3]
OnMeter=Water:Facility [m3]
OnMeter=Water:Plant [m3]
OnMeter=WaterSystems:Water [m3]
OnMeter=DHW 182393:WaterSystems:Water [m3]
Meters for 787,DHW 182393:Water Use Equipment Mains Water Volume [m3]
OnMeter=MainsWater:Facility [m3]
OnMeter=MainsWater:Plant [m3]
OnMeter=WaterSystems:MainsWater [m3]
OnMeter=DHW 182393:WaterSystems:MainsWater [m3]
Meters for 801,DHW 182393:Water Use Equipment Heating Energy [J]
OnMeter=DistrictHeating:Facility [J]
OnMeter=DistrictHeating:Plant [J]
OnMeter=WaterSystems:DistrictHeating [J]
OnMeter=DHW 182393:WaterSystems:DistrictHeating [J]
Meters for 814,Whole Building:Facility Total Purchased Electricity Energy [J]
OnMeter=ElectricityPurchased:Facility [J]
OnMeter=ElectricityPurchased:Plant [J]
OnMeter=Cogeneration:ElectricityPurchased [J]
OnMeter=General:Cogeneration:ElectricityPurchased [J]
Meters for 863,Whole Building:Facility Total Surplus Electricity Energy [J]
OnMeter=ElectricitySurplusSold:Facility [J]
OnMeter=ElectricitySurplusSold:Plant [J]
OnMeter=Cogeneration:ElectricitySurplusSold [J]
OnMeter=General:Cogeneration:ElectricitySurplusSold [J]
Meters for 912,Whole Building:Facility Net Purchased Electricity Energy [J]
OnMeter=ElectricityNet:Facility [J]
OnMeter=ElectricityNet:Plant [J]
OnMeter=Cogeneration:ElectricityNet [J]
OnMeter=General:Cogeneration:ElectricityNet [J]
Meters for 961,Site:Environmental Impact Total N2O Emissions Carbon Equivalent Mass [kg]
OnMeter=Carbon Equivalent:Facility [kg]
OnMeter=CarbonEquivalentEmissions:Carbon Equivalent [kg]
Meters for 986,Site:Environmental Impact Total CH4 Emissions Carbon Equivalent Mass [kg]
OnMeter=Carbon Equivalent:Facility [kg]
OnMeter=CarbonEquivalentEmissions:Carbon Equivalent [kg]
Meters for 987,Site:Environmental Impact Total CO2 Emissions Carbon Equivalent Mass [kg]
OnMeter=Carbon Equivalent:Facility [kg]
OnMeter=CarbonEquivalentEmissions:Carbon Equivalent [kg]
For Meter=Electricity:Facility [J], ResourceType=Electricity, contents are:
175785_LIGHTS:Lights Electricity Energy
176293_LIGHTS:Lights Electricity Energy
182393_LIGHTS:Lights Electricity Energy
175785_APPLIANCE:Other Equipment Electricity Energy
176293_APPLIANCE:Other Equipment Electricity Energy
182393_APPLIANCE:Other Equipment Electricity Energy
175785:Zone Ventilation Fan Electricity Energy
176293:Zone Ventilation Fan Electricity Energy
182393:Zone Ventilation Fan Electricity Energy
For Meter=Electricity:Building [J], ResourceType=Electricity, Group=Building, contents are:
175785_LIGHTS:Lights Electricity Energy
176293_LIGHTS:Lights Electricity Energy
182393_LIGHTS:Lights Electricity Energy
175785_APPLIANCE:Other Equipment Electricity Energy
176293_APPLIANCE:Other Equipment Electricity Energy
182393_APPLIANCE:Other Equipment Electricity Energy
175785:Zone Ventilation Fan Electricity Energy
176293:Zone Ventilation Fan Electricity Energy
182393:Zone Ventilation Fan Electricity Energy
For Meter=Electricity:Zone:175785 [J], ResourceType=Electricity, Group=Zone, contents are:
175785_LIGHTS:Lights Electricity Energy
175785_APPLIANCE:Other Equipment Electricity Energy
175785:Zone Ventilation Fan Electricity Energy
For Meter=InteriorLights:Electricity [J], ResourceType=Electricity, EndUse=InteriorLights, contents are:
175785_LIGHTS:Lights Electricity Energy
176293_LIGHTS:Lights Electricity Energy
182393_LIGHTS:Lights Electricity Energy
For Meter=InteriorLights:Electricity:Zone:175785 [J], ResourceType=Electricity, EndUse=InteriorLights, Group=Zone, contents are:
175785_LIGHTS:Lights Electricity Energy
For Meter=ELECTRIC EQUIPMENT#175785#GeneralLights:InteriorLights:Electricity [J], ResourceType=Electricity, EndUse=InteriorLights, contents are:
175785_LIGHTS:Lights Electricity Energy
For Meter=Electricity:Zone:176293 [J], ResourceType=Electricity, Group=Zone, contents are:
176293_LIGHTS:Lights Electricity Energy
176293_APPLIANCE:Other Equipment Electricity Energy
176293:Zone Ventilation Fan Electricity Energy
For Meter=InteriorLights:Electricity:Zone:176293 [J], ResourceType=Electricity, EndUse=InteriorLights, Group=Zone, contents are:
176293_LIGHTS:Lights Electricity Energy
For Meter=ELECTRIC EQUIPMENT#176293#GeneralLights:InteriorLights:Electricity [J], ResourceType=Electricity, EndUse=InteriorLights, contents are:
176293_LIGHTS:Lights Electricity Energy
For Meter=Electricity:Zone:182393 [J], ResourceType=Electricity, Group=Zone, contents are:
182393_LIGHTS:Lights Electricity Energy
182393_APPLIANCE:Other Equipment Electricity Energy
182393:Zone Ventilation Fan Electricity Energy
For Meter=InteriorLights:Electricity:Zone:182393 [J], ResourceType=Electricity, EndUse=InteriorLights, Group=Zone, contents are:
182393_LIGHTS:Lights Electricity Energy
For Meter=ELECTRIC EQUIPMENT#182393#GeneralLights:InteriorLights:Electricity [J], ResourceType=Electricity, EndUse=InteriorLights, contents are:
182393_LIGHTS:Lights Electricity Energy
For Meter=InteriorEquipment:Electricity [J], ResourceType=Electricity, EndUse=InteriorEquipment, contents are:
175785_APPLIANCE:Other Equipment Electricity Energy
176293_APPLIANCE:Other Equipment Electricity Energy
182393_APPLIANCE:Other Equipment Electricity Energy
For Meter=InteriorEquipment:Electricity:Zone:175785 [J], ResourceType=Electricity, EndUse=InteriorEquipment, Group=Zone, contents are:
175785_APPLIANCE:Other Equipment Electricity Energy
For Meter=ELECTRIC EQUIPMENT#175785#InteriorEquipment:InteriorEquipment:Electricity [J], ResourceType=Electricity, EndUse=InteriorEquipment, contents are:
175785_APPLIANCE:Other Equipment Electricity Energy
For Meter=InteriorEquipment:Electricity:Zone:176293 [J], ResourceType=Electricity, EndUse=InteriorEquipment, Group=Zone, contents are:
176293_APPLIANCE:Other Equipment Electricity Energy
For Meter=ELECTRIC EQUIPMENT#176293#InteriorEquipment:InteriorEquipment:Electricity [J], ResourceType=Electricity, EndUse=InteriorEquipment, contents are:
176293_APPLIANCE:Other Equipment Electricity Energy
For Meter=InteriorEquipment:Electricity:Zone:182393 [J], ResourceType=Electricity, EndUse=InteriorEquipment, Group=Zone, contents are:
182393_APPLIANCE:Other Equipment Electricity Energy
For Meter=ELECTRIC EQUIPMENT#182393#InteriorEquipment:InteriorEquipment:Electricity [J], ResourceType=Electricity, EndUse=InteriorEquipment, contents are:
182393_APPLIANCE:Other Equipment Electricity Energy
For Meter=Fans:Electricity [J], ResourceType=Electricity, EndUse=Fans, contents are:
175785:Zone Ventilation Fan Electricity Energy
176293:Zone Ventilation Fan Electricity Energy
182393:Zone Ventilation Fan Electricity Energy
For Meter=Fans:Electricity:Zone:175785 [J], ResourceType=Electricity, EndUse=Fans, Group=Zone, contents are:
175785:Zone Ventilation Fan Electricity Energy
For Meter=Ventilation (simple):Fans:Electricity [J], ResourceType=Electricity, EndUse=Fans, contents are:
175785:Zone Ventilation Fan Electricity Energy
176293:Zone Ventilation Fan Electricity Energy
182393:Zone Ventilation Fan Electricity Energy
For Meter=Fans:Electricity:Zone:176293 [J], ResourceType=Electricity, EndUse=Fans, Group=Zone, contents are:
176293:Zone Ventilation Fan Electricity Energy
For Meter=Fans:Electricity:Zone:182393 [J], ResourceType=Electricity, EndUse=Fans, Group=Zone, contents are:
182393:Zone Ventilation Fan Electricity Energy
For Meter=EnergyTransfer:Facility [J], ResourceType=EnergyTransfer, contents are:
175785:Zone Air System Sensible Heating Energy
175785:Zone Air System Sensible Cooling Energy
176293:Zone Air System Sensible Heating Energy
176293:Zone Air System Sensible Cooling Energy
182393:Zone Air System Sensible Heating Energy
182393:Zone Air System Sensible Cooling Energy
For Meter=EnergyTransfer:Building [J], ResourceType=EnergyTransfer, Group=Building, contents are:
175785:Zone Air System Sensible Heating Energy
175785:Zone Air System Sensible Cooling Energy
176293:Zone Air System Sensible Heating Energy
176293:Zone Air System Sensible Cooling Energy
182393:Zone Air System Sensible Heating Energy
182393:Zone Air System Sensible Cooling Energy
For Meter=EnergyTransfer:Zone:175785 [J], ResourceType=EnergyTransfer, Group=Zone, contents are:
175785:Zone Air System Sensible Heating Energy
175785:Zone Air System Sensible Cooling Energy
For Meter=Heating:EnergyTransfer [J], ResourceType=EnergyTransfer, EndUse=Heating, contents are:
175785:Zone Air System Sensible Heating Energy
176293:Zone Air System Sensible Heating Energy
182393:Zone Air System Sensible Heating Energy
For Meter=Heating:EnergyTransfer:Zone:175785 [J], ResourceType=EnergyTransfer, EndUse=Heating, Group=Zone, contents are:
175785:Zone Air System Sensible Heating Energy
For Meter=General:Heating:EnergyTransfer [J], ResourceType=EnergyTransfer, EndUse=Heating, contents are:
175785:Zone Air System Sensible Heating Energy
176293:Zone Air System Sensible Heating Energy
182393:Zone Air System Sensible Heating Energy
For Meter=Cooling:EnergyTransfer [J], ResourceType=EnergyTransfer, EndUse=Cooling, contents are:
175785:Zone Air System Sensible Cooling Energy
176293:Zone Air System Sensible Cooling Energy
182393:Zone Air System Sensible Cooling Energy
For Meter=Cooling:EnergyTransfer:Zone:175785 [J], ResourceType=EnergyTransfer, EndUse=Cooling, Group=Zone, contents are:
175785:Zone Air System Sensible Cooling Energy
For Meter=General:Cooling:EnergyTransfer [J], ResourceType=EnergyTransfer, EndUse=Cooling, contents are:
175785:Zone Air System Sensible Cooling Energy
176293:Zone Air System Sensible Cooling Energy
182393:Zone Air System Sensible Cooling Energy
For Meter=EnergyTransfer:Zone:176293 [J], ResourceType=EnergyTransfer, Group=Zone, contents are:
176293:Zone Air System Sensible Heating Energy
176293:Zone Air System Sensible Cooling Energy
For Meter=Heating:EnergyTransfer:Zone:176293 [J], ResourceType=EnergyTransfer, EndUse=Heating, Group=Zone, contents are:
176293:Zone Air System Sensible Heating Energy
For Meter=Cooling:EnergyTransfer:Zone:176293 [J], ResourceType=EnergyTransfer, EndUse=Cooling, Group=Zone, contents are:
176293:Zone Air System Sensible Cooling Energy
For Meter=EnergyTransfer:Zone:182393 [J], ResourceType=EnergyTransfer, Group=Zone, contents are:
182393:Zone Air System Sensible Heating Energy
182393:Zone Air System Sensible Cooling Energy
For Meter=Heating:EnergyTransfer:Zone:182393 [J], ResourceType=EnergyTransfer, EndUse=Heating, Group=Zone, contents are:
182393:Zone Air System Sensible Heating Energy
For Meter=Cooling:EnergyTransfer:Zone:182393 [J], ResourceType=EnergyTransfer, EndUse=Cooling, Group=Zone, contents are:
182393:Zone Air System Sensible Cooling Energy
For Meter=DistrictHeating:Facility [J], ResourceType=DistrictHeating, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
DHW 175785:Water Use Equipment Heating Energy
DHW 176293:Water Use Equipment Heating Energy
DHW 182393:Water Use Equipment Heating Energy
For Meter=DistrictHeating:HVAC [J], ResourceType=DistrictHeating, Group=HVAC, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
For Meter=Heating:DistrictHeating [J], ResourceType=DistrictHeating, EndUse=Heating, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
For Meter=General:Heating:DistrictHeating [J], ResourceType=DistrictHeating, EndUse=Heating, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy
For Meter=DistrictCooling:Facility [J], ResourceType=DistrictCooling, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
For Meter=DistrictCooling:HVAC [J], ResourceType=DistrictCooling, Group=HVAC, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
For Meter=Cooling:DistrictCooling [J], ResourceType=DistrictCooling, EndUse=Cooling, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
For Meter=General:Cooling:DistrictCooling [J], ResourceType=DistrictCooling, EndUse=Cooling, contents are:
175785 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
176293 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
182393 IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Cooling Energy
For Meter=Water:Facility [m3], ResourceType=Water, contents are:
DHW 175785:Water Use Equipment Total Volume
DHW 176293:Water Use Equipment Total Volume
DHW 182393:Water Use Equipment Total Volume
For Meter=Water:Plant [m3], ResourceType=Water, Group=Plant, contents are:
DHW 175785:Water Use Equipment Total Volume
DHW 176293:Water Use Equipment Total Volume
DHW 182393:Water Use Equipment Total Volume
For Meter=WaterSystems:Water [m3], ResourceType=Water, EndUse=WaterSystems, contents are:
DHW 175785:Water Use Equipment Total Volume
DHW 176293:Water Use Equipment Total Volume
DHW 182393:Water Use Equipment Total Volume
For Meter=DHW 175785:WaterSystems:Water [m3], ResourceType=Water, EndUse=WaterSystems, contents are:
DHW 175785:Water Use Equipment Total Volume
For Meter=MainsWater:Facility [m3], ResourceType=MainsWater, contents are:
DHW 175785:Water Use Equipment Mains Water Volume
DHW 176293:Water Use Equipment Mains Water Volume
DHW 182393:Water Use Equipment Mains Water Volume
For Meter=MainsWater:Plant [m3], ResourceType=MainsWater, Group=Plant, contents are:
DHW 175785:Water Use Equipment Mains Water Volume
DHW 176293:Water Use Equipment Mains Water Volume
DHW 182393:Water Use Equipment Mains Water Volume
For Meter=WaterSystems:MainsWater [m3], ResourceType=MainsWater, EndUse=WaterSystems, contents are:
DHW 175785:Water Use Equipment Mains Water Volume
DHW 176293:Water Use Equipment Mains Water Volume
DHW 182393:Water Use Equipment Mains Water Volume
For Meter=DHW 175785:WaterSystems:MainsWater [m3], ResourceType=MainsWater, EndUse=WaterSystems, contents are:
DHW 175785:Water Use Equipment Mains Water Volume
For Meter=DistrictHeating:Plant [J], ResourceType=DistrictHeating, Group=Plant, contents are:
DHW 175785:Water Use Equipment Heating Energy
DHW 176293:Water Use Equipment Heating Energy
DHW 182393:Water Use Equipment Heating Energy
For Meter=WaterSystems:DistrictHeating [J], ResourceType=DistrictHeating, EndUse=WaterSystems, contents are:
DHW 175785:Water Use Equipment Heating Energy
DHW 176293:Water Use Equipment Heating Energy
DHW 182393:Water Use Equipment Heating Energy
For Meter=DHW 175785:WaterSystems:DistrictHeating [J], ResourceType=DistrictHeating, EndUse=WaterSystems, contents are:
DHW 175785:Water Use Equipment Heating Energy
For Meter=DHW 176293:WaterSystems:Water [m3], ResourceType=Water, EndUse=WaterSystems, contents are:
DHW 176293:Water Use Equipment Total Volume
For Meter=DHW 176293:WaterSystems:MainsWater [m3], ResourceType=MainsWater, EndUse=WaterSystems, contents are:
DHW 176293:Water Use Equipment Mains Water Volume
For Meter=DHW 176293:WaterSystems:DistrictHeating [J], ResourceType=DistrictHeating, EndUse=WaterSystems, contents are:
DHW 176293:Water Use Equipment Heating Energy
For Meter=DHW 182393:WaterSystems:Water [m3], ResourceType=Water, EndUse=WaterSystems, contents are:
DHW 182393:Water Use Equipment Total Volume
For Meter=DHW 182393:WaterSystems:MainsWater [m3], ResourceType=MainsWater, EndUse=WaterSystems, contents are:
DHW 182393:Water Use Equipment Mains Water Volume
For Meter=DHW 182393:WaterSystems:DistrictHeating [J], ResourceType=DistrictHeating, EndUse=WaterSystems, contents are:
DHW 182393:Water Use Equipment Heating Energy
For Meter=ElectricityPurchased:Facility [J], ResourceType=ElectricityPurchased, contents are:
Whole Building:Facility Total Purchased Electricity Energy
For Meter=ElectricityPurchased:Plant [J], ResourceType=ElectricityPurchased, Group=Plant, contents are:
Whole Building:Facility Total Purchased Electricity Energy
For Meter=Cogeneration:ElectricityPurchased [J], ResourceType=ElectricityPurchased, EndUse=Cogeneration, contents are:
Whole Building:Facility Total Purchased Electricity Energy
For Meter=General:Cogeneration:ElectricityPurchased [J], ResourceType=ElectricityPurchased, EndUse=Cogeneration, contents are:
Whole Building:Facility Total Purchased Electricity Energy
For Meter=ElectricitySurplusSold:Facility [J], ResourceType=ElectricitySurplusSold, contents are:
Whole Building:Facility Total Surplus Electricity Energy
For Meter=ElectricitySurplusSold:Plant [J], ResourceType=ElectricitySurplusSold, Group=Plant, contents are:
Whole Building:Facility Total Surplus Electricity Energy
For Meter=Cogeneration:ElectricitySurplusSold [J], ResourceType=ElectricitySurplusSold, EndUse=Cogeneration, contents are:
Whole Building:Facility Total Surplus Electricity Energy
For Meter=General:Cogeneration:ElectricitySurplusSold [J], ResourceType=ElectricitySurplusSold, EndUse=Cogeneration, contents are:
Whole Building:Facility Total Surplus Electricity Energy
For Meter=ElectricityNet:Facility [J], ResourceType=ElectricityNet, contents are:
Whole Building:Facility Net Purchased Electricity Energy
For Meter=ElectricityNet:Plant [J], ResourceType=ElectricityNet, Group=Plant, contents are:
Whole Building:Facility Net Purchased Electricity Energy
For Meter=Cogeneration:ElectricityNet [J], ResourceType=ElectricityNet, EndUse=Cogeneration, contents are:
Whole Building:Facility Net Purchased Electricity Energy
For Meter=General:Cogeneration:ElectricityNet [J], ResourceType=ElectricityNet, EndUse=Cogeneration, contents are:
Whole Building:Facility Net Purchased Electricity Energy
For Meter=Carbon Equivalent:Facility [kg], ResourceType=Carbon Equivalent, contents are:
Site:Environmental Impact Total N2O Emissions Carbon Equivalent Mass
Site:Environmental Impact Total CH4 Emissions Carbon Equivalent Mass
Site:Environmental Impact Total CO2 Emissions Carbon Equivalent Mass
For Meter=CarbonEquivalentEmissions:Carbon Equivalent [kg], ResourceType=Carbon Equivalent, EndUse=CarbonEquivalentEmissions, contents are:
Site:Environmental Impact Total N2O Emissions Carbon Equivalent Mass
Site:Environmental Impact Total CH4 Emissions Carbon Equivalent Mass
Site:Environmental Impact Total CO2 Emissions Carbon Equivalent Mass

File diff suppressed because it is too large Load Diff

View File

@ -1,16 +0,0 @@
ReadVarsESO
processing:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_2b6a14.rvi
input file:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_out.eso
output file:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_out.csv
getting all vars from:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_out.eso
number variables requested for output= 19
ReadVars Run Time=00hr 00min 0.52sec
ReadVarsESO program completed successfully.
ReadVarsESO
processing:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_2b6a14.mvi
input file:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_out.mtr
output file:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_mtr.csv
getting all vars from:C:\Users\umroot\PycharmProjects\system_assignation\out_files\Montreal_out.mtr
number variables requested for output= 4
ReadVars Run Time=00hr 00min 0.14sec
ReadVarsESO program completed successfully.

View File

@ -1,221 +0,0 @@
Shadowing Combinations
..Solar Distribution=FullExterior
..In the following, only the first 10 reference surfaces will be shown.
..But all surfaces are used in the calculations.
==================================
Surface=FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=2
..Surface=F7A66C0B-F3E1-46C4-9AFE-F040250343B2
..Surface=A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A WINDOW
==================================
Surface=FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=4FA50238-068D-4E20-A2BA-8A5A0A93B796 is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=3B6D9D89-A422-445A-B305-4E9D2F952782 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=2
..Surface=9DCD5D84-78DF-4DA5-80C4-FAE17544226E
..Surface=F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=3B6D9D89-A422-445A-B305-4E9D2F952782 WINDOW
==================================
Surface=3B6D9D89-A422-445A-B305-4E9D2F952782 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=9DCD5D84-78DF-4DA5-80C4-FAE17544226E is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=2
..Surface=3B6D9D89-A422-445A-B305-4E9D2F952782
..Surface=F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=9DCD5D84-78DF-4DA5-80C4-FAE17544226E WINDOW
==================================
Surface=9DCD5D84-78DF-4DA5-80C4-FAE17544226E WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=C8CD208F-797F-428F-94DC-277ADC9EF001 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=C8CD208F-797F-428F-94DC-277ADC9EF001 WINDOW
==================================
Surface=C8CD208F-797F-428F-94DC-277ADC9EF001 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=3
..Surface=A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0
..Surface=EA75342E-1CCC-4A1D-9AE3-56FFEA395133
..Surface=48A796FD-5D1F-463D-9357-C9E2182110A4
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306 WINDOW
==================================
Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=6ACF7617-7D20-4059-916F-A322696BF7D6 is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=C17F7386-D2BC-4D4A-B05A-E846AAABA4C3 is used as Receiving Surface in calculations and is non-convex.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=F7A66C0B-F3E1-46C4-9AFE-F040250343B2 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=2
..Surface=FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A
..Surface=A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=F7A66C0B-F3E1-46C4-9AFE-F040250343B2 WINDOW
==================================
Surface=F7A66C0B-F3E1-46C4-9AFE-F040250343B2 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=673F9DDD-64F1-4F17-AD3B-320A0F77383B is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=673F9DDD-64F1-4F17-AD3B-320A0F77383B WINDOW
==================================
Surface=673F9DDD-64F1-4F17-AD3B-320A0F77383B WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=2
..Surface=3B6D9D89-A422-445A-B305-4E9D2F952782
..Surface=9DCD5D84-78DF-4DA5-80C4-FAE17544226E
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC WINDOW
==================================
Surface=F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=DAD33850-1CAC-42D6-BABA-76AA1E6E4A4D is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=7F337640-75A0-437B-8C4F-6EC6A6B647DF is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=69118BC1-AC76-440F-9C42-F25C672CE2F6 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=79EAC576-A260-4143-83B0-32CF204BBE7B is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=1
..Surface=958929BB-ACD4-4629-AB9F-B6984E758263
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=79EAC576-A260-4143-83B0-32CF204BBE7B WINDOW
==================================
Surface=79EAC576-A260-4143-83B0-32CF204BBE7B WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=3
..Surface=FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A
..Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306
..Surface=F7A66C0B-F3E1-46C4-9AFE-F040250343B2
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0 WINDOW
==================================
Surface=A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=EA75342E-1CCC-4A1D-9AE3-56FFEA395133 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=1
..Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=EA75342E-1CCC-4A1D-9AE3-56FFEA395133 WINDOW
==================================
Surface=EA75342E-1CCC-4A1D-9AE3-56FFEA395133 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=48A796FD-5D1F-463D-9357-C9E2182110A4 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=1
..Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=48A796FD-5D1F-463D-9357-C9E2182110A4 WINDOW
==================================
Surface=48A796FD-5D1F-463D-9357-C9E2182110A4 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=13EA4940-36E8-4E27-87EB-55C74E690355 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=13EA4940-36E8-4E27-87EB-55C74E690355 WINDOW
==================================
Surface=13EA4940-36E8-4E27-87EB-55C74E690355 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=958929BB-ACD4-4629-AB9F-B6984E758263 is used as Receiving Surface in calculations and is convex.
Number of general casting surfaces=1
..Surface=79EAC576-A260-4143-83B0-32CF204BBE7B
Number of back surfaces=0
Number of receiving sub surfaces=1
....Surface=958929BB-ACD4-4629-AB9F-B6984E758263 WINDOW
==================================
Surface=958929BB-ACD4-4629-AB9F-B6984E758263 WINDOW is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=6E6AFC12-5493-40C0-B7E5-DA42F550F2B5 is not used as Receiving Surface in calculations.
Number of general casting surfaces=0
Number of back surfaces=0
Number of receiving sub surfaces=0
==================================
Surface=0B62F37E-EDEC-4014-A6D4-01279F8A3493 is used as Receiving Surface in calculations and is non-convex.
Number of general casting surfaces=3
..Surface=FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A
..Surface=1B2839C9-4131-44CA-BD66-B4F56F1F1306
..Surface=F7A66C0B-F3E1-46C4-9AFE-F040250343B2
Number of back surfaces=0
Number of receiving sub surfaces=0

View File

@ -1,634 +0,0 @@
Program Version:,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11
Tabular Output Report in Format: ,Comma
Building:,Buildings in b'Montreal'
Environment:,RUN PERIOD 1 ** Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270
----------------------------------------------------------------------------------------------------
REPORT:,Annual Building Utility Performance Summary
FOR:,Entire Facility
Values gathered over 8760.00 hours
Site and Source Energy
,,Total Energy [kWh],Energy Per Total Building Area [kWh/m2],Energy Per Conditioned Building Area [kWh/m2]
,Total Site Energy,254015.03,821.95,821.95
,Net Site Energy,254015.03,821.95,821.95
,Total Source Energy,820655.39,2655.52,2655.52
,Net Source Energy,820655.39,2655.52,2655.52
Site to Source Energy Conversion Factors
,,Site=>Source Conversion Factor
,Electricity,3.167
,Natural Gas,1.084
,District Cooling,1.056
,District Heating,3.613
,Steam,1.200
,Gasoline,1.050
,Diesel,1.050
,Coal,1.050
,Fuel Oil No 1,1.050
,Fuel Oil No 2,1.050
,Propane,1.050
,Other Fuel 1,1.000
,Other Fuel 2,1.000
Building Area
,,Area [m2]
,Total Building Area,309.04
,Net Conditioned Building Area,309.04
,Unconditioned Building Area,0.00
End Uses
,,Electricity [kWh],Natural Gas [kWh],Gasoline [kWh],Diesel [kWh],Coal [kWh],Fuel Oil No 1 [kWh],Fuel Oil No 2 [kWh],Propane [kWh],Other Fuel 1 [kWh],Other Fuel 2 [kWh],District Cooling [kWh],District Heating [kWh],Water [m3]
,Heating,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,114133.39,0.00
,Cooling,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,32461.74,0.00,0.00
,Interior Lighting,11659.74,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Lighting,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Interior Equipment,20063.83,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Equipment,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Fans,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Pumps,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Rejection,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Humidification,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Recovery,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Water Systems,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,75696.33,1068.88
,Refrigeration,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Generators,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,,,,,,,,,,,,,
,Total End Uses,31723.57,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,32461.74,189829.73,1068.88
Note: District heat appears to be the principal heating source based on energy usage.
End Uses By Subcategory
,,Subcategory,Electricity [kWh],Natural Gas [kWh],Gasoline [kWh],Diesel [kWh],Coal [kWh],Fuel Oil No 1 [kWh],Fuel Oil No 2 [kWh],Propane [kWh],Other Fuel 1 [kWh],Other Fuel 2 [kWh],District Cooling [kWh],District Heating [kWh],Water [m3]
,Heating,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,114133.39,0.00
,Cooling,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,32461.74,0.00,0.00
,Interior Lighting,ELECTRIC EQUIPMENT#175785#GeneralLights,5260.06,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#176293#GeneralLights,4157.54,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#182393#GeneralLights,2242.14,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Lighting,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Interior Equipment,ELECTRIC EQUIPMENT#175785#InteriorEquipment,9051.40,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#176293#InteriorEquipment,7154.20,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#182393#InteriorEquipment,3858.22,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Equipment,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Fans,Ventilation (simple),0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Pumps,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Rejection,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Humidification,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Recovery,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Water Systems,DHW 175785,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,34148.92,482.20
,,DHW 176293,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,26991.20,381.13
,,DHW 182393,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,14556.22,205.54
,Refrigeration,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Generators,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
Normalized Metrics
Utility Use Per Conditioned Floor Area
,,Electricity Intensity [kWh/m2],Natural Gas Intensity [kWh/m2],Gasoline Intensity [kWh/m2],Diesel Intensity [kWh/m2],Coal Intensity [kWh/m2],Fuel Oil No 1 Intensity [kWh/m2],Fuel Oil No 2 Intensity [kWh/m2],Propane Intensity [kWh/m2],Other Fuel 1 Intensity [kWh/m2],Other Fuel 2 Intensity [kWh/m2],District Cooling Intensity [kWh/m2],District Heating Intensity [kWh/m2],Water Intensity [m3/m2]
,Lighting,37.73,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,HVAC,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
,Other,64.92,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Total,102.65,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
Utility Use Per Total Floor Area
,,Electricity Intensity [kWh/m2],Natural Gas Intensity [kWh/m2],Gasoline Intensity [kWh/m2],Diesel Intensity [kWh/m2],Coal Intensity [kWh/m2],Fuel Oil No 1 Intensity [kWh/m2],Fuel Oil No 2 Intensity [kWh/m2],Propane Intensity [kWh/m2],Other Fuel 1 Intensity [kWh/m2],Other Fuel 2 Intensity [kWh/m2],District Cooling Intensity [kWh/m2],District Heating Intensity [kWh/m2],Water Intensity [m3/m2]
,Lighting,37.73,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,HVAC,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
,Other,64.92,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Total,102.65,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
Electric Loads Satisfied
,,Electricity [kWh],Percent Electricity [%]
,Fuel-Fired Power Generation,0.000,0.00
,High Temperature Geothermal*,0.000,0.00
,Photovoltaic Power,0.000,0.00
,Wind Power,0.000,0.00
,Power Conversion,0.000,0.00
,Net Decrease in On-Site Storage,0.000,0.00
,Total On-Site Electric Sources,0.000,0.00
,,,
,Electricity Coming From Utility,31723.568,100.00
,Surplus Electricity Going To Utility,0.000,0.00
,Net Electricity From Utility,31723.568,100.00
,,,
,Total On-Site and Utility Electric Sources,31723.568,100.00
,Total Electricity End Uses,31723.568,100.00
On-Site Thermal Sources
,,Heat [kWh],Percent Heat [%]
,Water-Side Heat Recovery,0.00,
,Air to Air Heat Recovery for Cooling,0.00,
,Air to Air Heat Recovery for Heating,0.00,
,High-Temperature Geothermal*,0.00,
,Solar Water Thermal,0.00,
,Solar Air Thermal,0.00,
,Total On-Site Thermal Sources,0.00,
Water Source Summary
,,Water [m3],Percent Water [%]
,Rainwater Collection,0.00,0.00
,Condensate Collection,0.00,0.00
,Groundwater Well,0.00,0.00
,Total On Site Water Sources,0.00,0.00
,-,-,-
,Initial Storage,0.00,0.00
,Final Storage,0.00,0.00
,Change in Storage,0.00,0.00
,-,-,-
,Water Supplied by Utility,1068.88,100.00
,-,-,-
,Total On Site, Change in Storage, and Utility Water Sources,1068.88,100.00
,Total Water End Uses,1068.88,100.00
Setpoint Not Met Criteria
,,Degrees [deltaC]
,Tolerance for Zone Heating Setpoint Not Met Time,0.20
,Tolerance for Zone Cooling Setpoint Not Met Time,0.20
Comfort and Setpoint Not Met Summary
,,Facility [Hours]
,Time Setpoint Not Met During Occupied Heating,0.00
,Time Setpoint Not Met During Occupied Cooling,0.00
,Time Not Comfortable Based on Simple ASHRAE 55-2004,5311.25
Note 1: An asterisk (*) indicates that the feature is not yet implemented.
----------------------------------------------------------------------------------------------------
REPORT:,Input Verification and Results Summary
FOR:,Entire Facility
General
,,Value
,Program Version and Build,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11
,RunPeriod,RUN PERIOD 1
,Weather File,Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270
,Latitude [deg],45.47
,Longitude [deg],-73.8
,Elevation [m],36.00
,Time Zone,-5.0
,North Axis Angle [deg],0.00
,Rotation for Appendix G [deg],0.00
,Hours Simulated [hrs],8760.00
ENVELOPE
Window-Wall Ratio
,,Total,North (315 to 45 deg),East (45 to 135 deg),South (135 to 225 deg),West (225 to 315 deg)
,Gross Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
,Above Ground Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
,Window Opening Area [m2],215.26,65.34,41.85,65.26,42.82
,Gross Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
,Above Ground Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
Conditioned Window-Wall Ratio
,,Total,North (315 to 45 deg),East (45 to 135 deg),South (135 to 225 deg),West (225 to 315 deg)
,Gross Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
,Above Ground Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
,Window Opening Area [m2],215.26,65.34,41.85,65.26,42.82
,Gross Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
,Above Ground Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
Skylight-Roof Ratio
,,Total
,Gross Roof Area [m2],309.04
,Skylight Area [m2],0.00
,Skylight-Roof Ratio [%],0.00
PERFORMANCE
Zone Summary
,,Area [m2],Conditioned (Y/N),Part of Total Floor Area (Y/N),Volume [m3],Multipliers,Above Ground Gross Wall Area [m2],Underground Gross Wall Area [m2],Window Glass Area [m2],Opening Area [m2],Lighting [W/m2],People [m2 per person],Plug and Process [W/m2]
,175785,116.93,Yes,Yes,1403.17,1.00,410.07,0.00,81.93,81.93,22.0080,6.25,20.0073
,176293,92.42,Yes,Yes,1109.06,1.00,326.92,0.00,65.32,65.32,22.0080,6.25,20.0073
,182393,99.69,Yes,Yes,797.48,1.00,340.41,0.00,68.01,68.01,11.0040,12.50,10.0036
,Total,309.04,,,3309.71,,1077.40,0.00,215.26,215.26,18.4585,7.45,16.7804
,Conditioned Total,309.04,,,3309.71,,1077.40,0.00,215.26,215.26,18.4585,7.45,16.7804
,Unconditioned Total,0.00,,,0.00,,0.00,0.00,0.00,0.00,,,
,Not Part of Total,0.00,,,0.00,,0.00,0.00,0.00,0.00,,,
----------------------------------------------------------------------------------------------------
REPORT:,Demand End Use Components Summary
FOR:,Entire Facility
End Uses
,,Electricity [W],Natural Gas [W],Gasoline [W],Diesel [W],Coal [W],Fuel Oil No 1 [W],Fuel Oil No 2 [W],Propane [W],Other Fuel 1 [W],Other Fuel 2 [W],District Cooling [W],District Heating [W],Water [m3/s]
,Time of Peak,01-JAN-19:15,-,-,-,-,-,-,-,-,-,20-JUL-16:30,04-FEB-07:15,10-AUG-16:15
,Heating,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,72233.34,0.00
,Cooling,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,45602.66,0.00,0.00
,Interior Lighting,5133.93,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Lighting,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Interior Equipment,4667.21,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Equipment,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Fans,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Pumps,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Rejection,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Humidification,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Recovery,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Water Systems,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,20682.68,0.00
,Refrigeration,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Generators,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,,,,,,,,,,,,,
,Total End Uses,9801.15,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,45602.66,92916.02,0.00
End Uses By Subcategory
,,Subcategory,Electricity [W],Natural Gas [W],Gasoline [W],Diesel [W],Coal [W],Fuel Oil No 1 [W],Fuel Oil No 2 [W],Propane [W],Other Fuel 1 [W],Other Fuel 2 [W],District Cooling [W],District Heating [W],Water [m3/s]
,Heating,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,72233.34,0.00
,Cooling,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,45602.66,0.00,0.00
,Interior Lighting,ELECTRIC EQUIPMENT#175785#GeneralLights,2316.07,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#176293#GeneralLights,1830.62,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#182393#GeneralLights,987.24,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Lighting,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Interior Equipment,ELECTRIC EQUIPMENT#175785#InteriorEquipment,2105.52,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#176293#InteriorEquipment,1664.20,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,,ELECTRIC EQUIPMENT#182393#InteriorEquipment,897.49,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Exterior Equipment,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Fans,Ventilation (simple),0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Pumps,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Rejection,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Humidification,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Heat Recovery,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Water Systems,DHW 175785,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,9330.58,0.00
,,DHW 176293,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,7374.87,0.00
,,DHW 182393,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,3977.23,0.00
,Refrigeration,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
,Generators,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
----------------------------------------------------------------------------------------------------
REPORT:,Component Sizing Summary
FOR:,Entire Facility
----------------------------------------------------------------------------------------------------
REPORT:,Adaptive Comfort Summary
FOR:,Entire Facility
Time Not Meeting the Adaptive Comfort Models during Occupied Hours
,,ASHRAE55 90% Acceptability Limits [Hours],ASHRAE55 80% Acceptability Limits [Hours],CEN15251 Category I Acceptability Limits [Hours],CEN15251 Category II Acceptability Limits [Hours],CEN15251 Category III Acceptability Limits [Hours]
----------------------------------------------------------------------------------------------------
REPORT:,Climatic Data Summary
FOR:,Entire Facility
SizingPeriod:DesignDay
,,Maximum Dry Bulb [C],Daily Temperature Range [deltaC],Humidity Value,Humidity Type,Wind Speed [m/s],Wind Direction
,None,,,,,,
Weather Statistics File
,,Value
,None,
----------------------------------------------------------------------------------------------------
REPORT:,Envelope Summary
FOR:,Entire Facility
Opaque Exterior
,,Construction,Reflectance,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Net Area [m2],Azimuth [deg],Tilt [deg],Cardinal Direction
,FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A,1981_1990_6,0.40,0.644,0.713,79.35,63.50,89.98,90.00,E
,3B6D9D89-A422-445A-B305-4E9D2F952782,1981_1990_6,0.40,0.644,0.713,1.88,1.50,270.07,90.00,W
,9DCD5D84-78DF-4DA5-80C4-FAE17544226E,1981_1990_6,0.40,0.644,0.713,38.53,30.83,0.07,90.00,N
,C8CD208F-797F-428F-94DC-277ADC9EF001,1981_1990_6,0.40,0.644,0.713,77.98,62.40,269.91,90.00,W
,1B2839C9-4131-44CA-BD66-B4F56F1F1306,1981_1990_6,0.40,0.644,0.713,212.34,169.91,179.99,90.00,S
,6ACF7617-7D20-4059-916F-A322696BF7D6,1981_1990_6,0.40,0.639,0.713,116.93,116.93,359.99,180.00,
,C17F7386-D2BC-4D4A-B05A-E846AAABA4C3,1981_1990_6,0.40,0.649,0.713,116.93,116.93,0.13,0.00,
,F7A66C0B-F3E1-46C4-9AFE-F040250343B2,1981_1990_6,0.40,0.644,0.713,76.55,61.25,89.98,90.00,E
,673F9DDD-64F1-4F17-AD3B-320A0F77383B,1981_1990_6,0.40,0.644,0.713,173.82,139.09,0.13,90.00,N
,F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC,1981_1990_6,0.40,0.644,0.713,76.55,61.25,270.04,90.00,W
,7F337640-75A0-437B-8C4F-6EC6A6B647DF,1981_1990_6,0.40,0.639,0.713,92.42,92.42,0.13,180.00,
,69118BC1-AC76-440F-9C42-F25C672CE2F6,1981_1990_6,0.40,0.649,0.713,92.42,92.42,0.13,0.00,
,79EAC576-A260-4143-83B0-32CF204BBE7B,1981_1990_6,0.40,0.644,0.713,3.22,2.58,91.08,90.00,E
,A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0,1981_1990_6,0.40,0.644,0.713,106.72,85.40,2.33,90.00,N
,EA75342E-1CCC-4A1D-9AE3-56FFEA395133,1981_1990_6,0.40,0.644,0.713,7.94,6.35,1.96,90.00,N
,48A796FD-5D1F-463D-9357-C9E2182110A4,1981_1990_6,0.40,0.644,0.713,57.91,46.34,270.12,90.00,W
,13EA4940-36E8-4E27-87EB-55C74E690355,1981_1990_6,0.40,0.644,0.713,114.28,91.44,180.13,90.00,S
,958929BB-ACD4-4629-AB9F-B6984E758263,1981_1990_6,0.40,0.644,0.713,50.34,40.28,90.40,90.00,E
,6E6AFC12-5493-40C0-B7E5-DA42F550F2B5,1981_1990_6,0.40,0.639,0.713,99.69,99.69,270.40,180.00,
,0B62F37E-EDEC-4014-A6D4-01279F8A3493,1981_1990_6,0.40,0.649,0.713,99.69,99.69,91.08,0.00,
Opaque Interior
,,Construction,Reflectance,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Net Area [m2],Azimuth [deg],Tilt [deg],Cardinal Direction
,4FA50238-068D-4E20-A2BA-8A5A0A93B796,1981_1990_6,0.40,0.609,0.713,173.90,173.90,0.13,90.00,N
,DAD33850-1CAC-42D6-BABA-76AA1E6E4A4D,1981_1990_6,0.40,0.609,0.713,173.90,173.90,180.13,90.00,S
Exterior Fenestration
,,Construction,Glass Area [m2],Frame Area [m2],Divider Area [m2],Area of One Opening [m2],Area of Multiplied Openings [m2],Glass U-Factor [W/m2-K],Glass SHGC,Glass Visible Transmittance,Frame Conductance [W/m2-K],Divider Conductance [W/m2-K],Shade Control,Parent Surface,Azimuth [deg],Tilt [deg],Cardinal Direction
,FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A WINDOW,WINDOW_CONSTRUCTION_1,15.85,0.00,0.00,15.85,15.85,2.954,0.391,0.305,,,No,FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A,89.98,90.00,E
,3B6D9D89-A422-445A-B305-4E9D2F952782 WINDOW,WINDOW_CONSTRUCTION_1,0.37,0.00,0.00,0.37,0.37,2.954,0.391,0.305,,,No,3B6D9D89-A422-445A-B305-4E9D2F952782,270.07,90.00,W
,9DCD5D84-78DF-4DA5-80C4-FAE17544226E WINDOW,WINDOW_CONSTRUCTION_1,7.70,0.00,0.00,7.70,7.70,2.954,0.391,0.305,,,No,9DCD5D84-78DF-4DA5-80C4-FAE17544226E,0.07,90.00,N
,C8CD208F-797F-428F-94DC-277ADC9EF001 WINDOW,WINDOW_CONSTRUCTION_1,15.58,0.00,0.00,15.58,15.58,2.954,0.391,0.305,,,No,C8CD208F-797F-428F-94DC-277ADC9EF001,269.91,90.00,W
,1B2839C9-4131-44CA-BD66-B4F56F1F1306 WINDOW,WINDOW_CONSTRUCTION_1,42.43,0.00,0.00,42.43,42.43,2.954,0.391,0.305,,,No,1B2839C9-4131-44CA-BD66-B4F56F1F1306,179.99,90.00,S
,F7A66C0B-F3E1-46C4-9AFE-F040250343B2 WINDOW,WINDOW_CONSTRUCTION_1,15.29,0.00,0.00,15.29,15.29,2.954,0.391,0.305,,,No,F7A66C0B-F3E1-46C4-9AFE-F040250343B2,89.98,90.00,E
,673F9DDD-64F1-4F17-AD3B-320A0F77383B WINDOW,WINDOW_CONSTRUCTION_1,34.73,0.00,0.00,34.73,34.73,2.954,0.391,0.305,,,No,673F9DDD-64F1-4F17-AD3B-320A0F77383B,0.13,90.00,N
,F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC WINDOW,WINDOW_CONSTRUCTION_1,15.29,0.00,0.00,15.29,15.29,2.954,0.391,0.305,,,No,F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC,270.04,90.00,W
,79EAC576-A260-4143-83B0-32CF204BBE7B WINDOW,WINDOW_CONSTRUCTION_1,0.64,0.00,0.00,0.64,0.64,2.954,0.391,0.305,,,No,79EAC576-A260-4143-83B0-32CF204BBE7B,91.08,90.00,E
,A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0 WINDOW,WINDOW_CONSTRUCTION_1,21.32,0.00,0.00,21.32,21.32,2.954,0.391,0.305,,,No,A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0,2.33,90.00,N
,EA75342E-1CCC-4A1D-9AE3-56FFEA395133 WINDOW,WINDOW_CONSTRUCTION_1,1.59,0.00,0.00,1.59,1.59,2.954,0.391,0.305,,,No,EA75342E-1CCC-4A1D-9AE3-56FFEA395133,1.96,90.00,N
,48A796FD-5D1F-463D-9357-C9E2182110A4 WINDOW,WINDOW_CONSTRUCTION_1,11.57,0.00,0.00,11.57,11.57,2.954,0.391,0.305,,,No,48A796FD-5D1F-463D-9357-C9E2182110A4,270.12,90.00,W
,13EA4940-36E8-4E27-87EB-55C74E690355 WINDOW,WINDOW_CONSTRUCTION_1,22.83,0.00,0.00,22.83,22.83,2.954,0.391,0.305,,,No,13EA4940-36E8-4E27-87EB-55C74E690355,180.13,90.00,S
,958929BB-ACD4-4629-AB9F-B6984E758263 WINDOW,WINDOW_CONSTRUCTION_1,10.06,0.00,0.00,10.06,10.06,2.954,0.391,0.305,,,No,958929BB-ACD4-4629-AB9F-B6984E758263,90.40,90.00,E
,Total or Average,,,,,,215.26,2.954,0.391,0.305,,,,,,,
,North Total or Average,,,,,,65.34,2.954,0.391,0.305,,,,,,,
,Non-North Total or Average,,,,,,149.93,2.954,0.391,0.305,,,,,,,
Interior Fenestration
,,Construction,Area of One Opening [m2],Area of Openings [m2],Glass U-Factor [W/m2-K],Glass SHGC,Glass Visible Transmittance,Parent Surface
,Total or Average,,,0.00,-,-,-,
Exterior Door
,,Construction,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Parent Surface
,None,,,,,
Interior Door
,,Construction,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Parent Surface
,None,,,,,
----------------------------------------------------------------------------------------------------
REPORT:,Lighting Summary
FOR:,Entire Facility
Interior Lighting
,,Zone,Lighting Power Density [W/m2],Zone Area [m2],Total Power [W],End Use Subcategory,Schedule Name,Scheduled Hours/Week [hr],Hours/Week > 1% [hr],Full Load Hours/Week [hr],Return Air Fraction,Conditioned (Y/N),Consumption [kWh]
,175785_LIGHTS,175785,22.0080,116.93,2573.42,ELECTRIC EQUIPMENT#175785#GeneralLights,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,39.20,63.00,39.20,0.0000,Y,5259.87
,176293_LIGHTS,176293,22.0080,92.42,2034.02,ELECTRIC EQUIPMENT#176293#GeneralLights,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,39.20,63.00,39.20,0.0000,Y,4157.39
,182393_LIGHTS,182393,11.0040,99.69,1096.94,ELECTRIC EQUIPMENT#182393#GeneralLights,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,39.20,63.00,39.20,0.0000,Y,2242.06
,Interior Lighting Total,,18.4585,309.04,5704.37,,,,,,,,11659.32
Daylighting
,,Zone,Control Name,Daylighting Method,Control Type,Fraction Controlled,Lighting Installed in Zone [W],Lighting Controlled [W]
,None,,,,,,,
Exterior Lighting
,,Total Watts,Astronomical Clock/Schedule,Schedule Name,Scheduled Hours/Week [hr],Hours/Week > 1% [hr],Full Load Hours/Week [hr],Consumption [kWh]
,Exterior Lighting Total,0.00,,,,,,0.00
----------------------------------------------------------------------------------------------------
REPORT:,Equipment Summary
FOR:,Entire Facility
Central Plant
,,Type,Nominal Capacity [W],Nominal Efficiency [W/W],IPLV in SI Units [W/W],IPLV in IP Units [Btu/W-h]
,None,,,,,
Cooling Coils
,,Type,Design Coil Load [W],Nominal Total Capacity [W],Nominal Sensible Capacity [W],Nominal Latent Capacity [W],Nominal Sensible Heat Ratio,Nominal Efficiency [W/W],Nominal Coil UA Value [W/C],Nominal Coil Surface Area [m2]
,None,,,,,,,,,
DX Cooling Coils
,,DX Cooling Coil Type,Standard Rated Net Cooling Capacity [W],Standard Rated Net COP [W/W],EER [Btu/W-h],SEER User [Btu/W-h],SEER Standard [Btu/W-h],IEER [Btu/W-h]
,None,,,,,,,
DX Cooling Coil ASHRAE 127 Standard Ratings Report
,,DX Cooling Coil Type,Rated Net Cooling Capacity Test A [W],Rated Electric Power Test A [W],Rated Net Cooling Capacity Test B [W],Rated Electric Power Test B [W],Rated Net Cooling Capacity Test C [W],Rated Electric Power Test C [W],Rated Net Cooling Capacity Test D [W],Rated Electric Power Test D [W]
,None,,,,,,,,,
DX Heating Coils
,,DX Heating Coil Type,High Temperature Heating (net) Rating Capacity [W],Low Temperature Heating (net) Rating Capacity [W],HSPF [Btu/W-h],Region Number
,None,,,,,
Heating Coils
,,Type,Design Coil Load [W],Nominal Total Capacity [W],Nominal Efficiency [W/W]
,None,,,,
Fans
,,Type,Total Efficiency [W/W],Delta Pressure [pa],Max Air Flow Rate [m3/s],Rated Electricity Rate [W],Rated Power Per Max Air Flow Rate [W-s/m3],Motor Heat In Air Fraction,Fan Energy Index,End Use Subcategory,Design Day Name for Fan Sizing Peak,Date/Time for Fan Sizing Peak
,None,,,,,,,,,,,
Pumps
,,Type,Control,Head [pa],Water Flow [m3/s],Electricity Rate [W],Power Per Water Flow Rate [W-s/m3],Motor Efficiency [W/W],End Use Subcategory
,None,,,,,,,,
Service Water Heating
,,Type,Storage Volume [m3],Input [W],Thermal Efficiency [W/W],Recovery Efficiency [W/W],Energy Factor
,None,,,,,,
----------------------------------------------------------------------------------------------------
REPORT:,HVAC Sizing Summary
FOR:,Entire Facility
Zone Sensible Cooling
,,Calculated Design Load [W],User Design Load [W],User Design Load per Area [W/m2],Calculated Design Air Flow [m3/s],User Design Air Flow [m3/s],Design Day Name,Date/Time Of Peak {TIMESTAMP},Thermostat Setpoint Temperature at Peak Load [C],Indoor Temperature at Peak Load [C],Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Outdoor Temperature at Peak Load [C],Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Minimum Outdoor Air Flow Rate [m3/s],Heat Gain Rate from DOAS [W]
,None,,,,,,,,,,,,,,
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.
Zone Sensible Heating
,,Calculated Design Load [W],User Design Load [W],User Design Load per Area [W/m2],Calculated Design Air Flow [m3/s],User Design Air Flow [m3/s],Design Day Name,Date/Time Of Peak {TIMESTAMP},Thermostat Setpoint Temperature at Peak Load [C],Indoor Temperature at Peak Load [C],Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Outdoor Temperature at Peak Load [C],Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Minimum Outdoor Air Flow Rate [m3/s],Heat Gain Rate from DOAS [W]
,None,,,,,,,,,,,,,,
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.
System Design Air Flow Rates
,,Calculated cooling [m3/s],User cooling [m3/s],Calculated heating [m3/s],User heating [m3/s],Adjusted cooling [m3/s],Adjusted heating [m3/s],Adjusted main [m3/s],Calculated Heating Air Flow Ratio [],User Heating Air Flow Ratio []
,None,,,,,,,,,
Plant Loop Coincident Design Fluid Flow Rate Adjustments
,,Previous Design Volume Flow Rate [m3/s],Algorithm Volume Flow Rate [m3/s],Coincident Design Volume Flow Rate [m3/s],Coincident Size Adjusted,Peak Sizing Period Name,Peak Day into Period {TIMESTAMP}[day],Peak Hour Of Day {TIMESTAMP}[hr],Peak Step Start Minute {TIMESTAMP}[min]
,None,,,,,,,,
Coil Sizing Summary
,,Coil Type,HVAC Type,HVAC Name,Coil Final Gross Total Capacity [W],Coil Final Gross Sensible Capacity [W],Coil Final Reference Air Volume Flow Rate [m3/s],Coil Final Reference Plant Fluid Volume Flow Rate [m3/s],Coil U-value Times Area Value [W/K],Design Day Name at Sensible Ideal Loads Peak,Date/Time at Sensible Ideal Loads Peak,Design Day Name at Air Flow Ideal Loads Peak,Date/Time at Air Flow Ideal Loads Peak,Coil Total Capacity at Ideal Loads Peak [W],Coil Sensible Capacity at Ideal Loads Peak [W],Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s],Coil Entering Air Drybulb at Ideal Loads Peak [C],Coil Entering Air Wetbulb at Ideal Loads Peak [C],Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Coil Leaving Air Drybulb at Ideal Loads Peak [C],Coil Leaving Air Wetbulb at Ideal Loads Peak [C],Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Outdoor Air Drybulb at Ideal Loads Peak [C],Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Outdoor Air Wetbulb at Ideal Loads Peak [C],Outdoor Air Flow Percentage at Ideal Loads Peak [%],Zone Air Drybulb at Ideal Loads Peak [C],Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Zone Air Relative Humidity at Ideal Loads Peak [%],Zone Sensible Heat Gain at Ideal Loads Peak [W],Zone Latent Heat Gain at Ideal Loads Peak [W],Coil Total Capacity at Rating Conditions [W],Coil Sensible Capacity at Rating Conditions [W]
,None,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
----------------------------------------------------------------------------------------------------
REPORT:,System Summary
FOR:,Entire Facility
Economizer
,,High Limit Shutoff Control,Minimum Outdoor Air [m3/s],Maximum Outdoor Air [m3/s],Return Air Temp Limit,Return Air Enthalpy Limit,Outdoor Air Temperature Limit [C],Outdoor Air Enthalpy Limit [C]
,None,,,,,,,
Demand Controlled Ventilation using Controller:MechanicalVentilation
,,Controller:MechanicalVentilation Name,Outdoor Air Per Person [m3/s-person],Outdoor Air Per Area [m3/s-m2],Outdoor Air Per Zone [m3/s],Outdoor Air ACH [ach],Outdoor Air Method,Outdoor Air Schedule Name,Air Distribution Effectiveness in Cooling Mode,Air Distribution Effectiveness in Heating Mode,Air Distribution Effectiveness Schedule Name
,None,,,,,,,,,,
Time Not Comfortable Based on Simple ASHRAE 55-2004
,,Winter Clothes [hr],Summer Clothes [hr],Summer or Winter Clothes [hr]
,175785,6488.00,6546.00,4705.50
,176293,6574.50,6807.50,5004.50
,182393,6624.75,6733.50,5006.75
,Facility,7106.25,7011.75,5311.25
Aggregated over the RunPeriods for Weather
Time Setpoint Not Met
,,During Heating [hr],During Cooling [hr],During Occupied Heating [hr],During Occupied Cooling [hr]
,175785,0.00,0.00,0.00,0.00
,176293,0.00,0.00,0.00,0.00
,182393,0.00,0.00,0.00,0.00
,Facility,0.00,0.00,0.00,0.00
Aggregated over the RunPeriods for Weather
----------------------------------------------------------------------------------------------------
REPORT:,Outdoor Air Summary
FOR:,Entire Facility
Average Outdoor Air During Occupied Hours
,,Average Number of Occupants,Nominal Number of Occupants,Zone Volume [m3],Mechanical Ventilation [ach],Infiltration [ach],AFN Infiltration [ach],Simple Ventilation [ach]
,175785,12.66,18.72,1403.17,0.000,0.000,0.000,0.387
,176293,10.01,14.79,1109.06,0.000,0.000,0.000,0.387
,182393,5.40,7.98,797.48,0.000,0.000,0.000,0.290
Values shown for a single zone without multipliers
Minimum Outdoor Air During Occupied Hours
,,Average Number of Occupants,Nominal Number of Occupants,Zone Volume [m3],Mechanical Ventilation [ach],Infiltration [ach],AFN Infiltration [ach],Simple Ventilation [ach]
,175785,12.66,18.72,1403.17,0.000,0.000,0.000,0.007
,176293,10.01,14.79,1109.06,0.000,0.000,0.000,0.007
,182393,5.40,7.98,797.48,0.000,0.000,0.000,0.005
Values shown for a single zone without multipliers
----------------------------------------------------------------------------------------------------
REPORT:,Object Count Summary
FOR:,Entire Facility
Surfaces by Class
,,Total,Outdoors
,Wall,16,14
,Floor,3,3
,Roof,3,3
,Internal Mass,0,0
,Building Detached Shading,0,0
,Fixed Detached Shading,0,0
,Window,14,14
,Door,0,0
,Glass Door,0,0
,Shading,0,0
,Overhang,0,0
,Fin,0,0
,Tubular Daylighting Device Dome,0,0
,Tubular Daylighting Device Diffuser,0,0
HVAC
,,Count
,HVAC Air Loops,0
,Conditioned Zones,3
,Unconditioned Zones,0
,Supply Plenums,0
,Return Plenums,0
Input Fields
,,Count
,IDF Objects,113
,Defaulted Fields,8
,Fields with Defaults,401
,Autosized Fields,0
,Autosizable Fields,12
,Autocalculated Fields,81
,Autocalculatable Fields,84
----------------------------------------------------------------------------------------------------
REPORT:,Sensible Heat Gain Summary
FOR:,Entire Facility
Annual Building Sensible Heat Gain Components
,,HVAC Zone Eq & Other Sensible Air Heating [kWh],HVAC Zone Eq & Other Sensible Air Cooling [kWh],HVAC Terminal Unit Sensible Air Heating [kWh],HVAC Terminal Unit Sensible Air Cooling [kWh],HVAC Input Heated Surface Heating [kWh],HVAC Input Cooled Surface Cooling [kWh],People Sensible Heat Addition [kWh],Lights Sensible Heat Addition [kWh],Equipment Sensible Heat Addition [kWh],Window Heat Addition [kWh],Interzone Air Transfer Heat Addition [kWh],Infiltration Heat Addition [kWh],Opaque Surface Conduction and Other Heat Addition [kWh],Equipment Sensible Heat Removal [kWh],Window Heat Removal [kWh],Interzone Air Transfer Heat Removal [kWh],Infiltration Heat Removal [kWh],Opaque Surface Conduction and Other Heat Removal [kWh]
,175785,43048.351,-12346.47,0.000,0.000,0.000,0.000,9408.890,5260.065,9051.411,14802.112,0.000,161.085,0.000,0.000,-17395.07,0.000,-25721.02,-26269.36
,176293,38609.040,-7666.35,0.000,0.000,0.000,0.000,7449.341,4157.541,7154.210,7096.867,0.000,127.321,0.000,0.000,-14980.01,0.000,-20253.67,-21694.29
,182393,32346.619,-7050.46,0.000,0.000,0.000,0.000,4038.987,2242.140,3858.228,10037.769,0.000,69.058,0.000,0.000,-14033.41,0.000,-10884.82,-20624.10
,Total Facility,114004.011,-27063.27,0.000,0.000,0.000,0.000,20897.218,11659.746,20063.848,31936.748,0.000,357.465,0.000,0.000,-46408.49,0.000,-56859.52,-68587.75
Peak Cooling Sensible Heat Gain Components
,,Time of Peak {TIMESTAMP},HVAC Zone Eq & Other Sensible Air Heating [W],HVAC Zone Eq & Other Sensible Air Cooling [W],HVAC Terminal Unit Sensible Air Heating [W],HVAC Terminal Unit Sensible Air Cooling [W],HVAC Input Heated Surface Heating [W],HVAC Input Cooled Surface Cooling [W],People Sensible Heat Addition [W],Lights Sensible Heat Addition [W],Equipment Sensible Heat Addition [W],Window Heat Addition [W],Interzone Air Transfer Heat Addition [W],Infiltration Heat Addition [W],Opaque Surface Conduction and Other Heat Addition [W],Equipment Sensible Heat Removal [W],Window Heat Removal [W],Interzone Air Transfer Heat Removal [W],Infiltration Heat Removal [W],Opaque Surface Conduction and Other Heat Removal [W]
,175785,15-AUG-14:00,0.00,-17068.90,0.00,0.00,0.00,0.00,410.61,0.00,935.79,11320.00,0.00,1194.62,3207.88,0.00,-0.00,0.00,0.00,0.00
,176293,19-JUL-18:30,0.00,-11505.90,0.00,0.00,0.00,0.00,973.64,0.00,1664.20,6601.36,0.00,713.40,1553.30,0.00,-0.00,0.00,0.00,0.00
,182393,15-AUG-14:00,0.00,-11080.13,0.00,0.00,0.00,0.00,175.03,0.00,398.89,7757.96,0.00,510.12,2238.15,0.00,-0.00,0.00,0.00,0.00
,Total Facility,15-AUG-14:30,0.00,-37585.08,0.00,0.00,0.00,0.00,910.18,0.00,2074.32,23736.81,0.00,2647.74,8216.03,0.00,0.00,0.00,0.00,0.00
Peak Heating Sensible Heat Gain Components
,,Time of Peak {TIMESTAMP},HVAC Zone Eq & Other Sensible Air Heating [W],HVAC Zone Eq & Other Sensible Air Cooling [W],HVAC Terminal Unit Sensible Air Heating [W],HVAC Terminal Unit Sensible Air Cooling [W],HVAC Input Heated Surface Heating [W],HVAC Input Cooled Surface Cooling [W],People Sensible Heat Addition [W],Lights Sensible Heat Addition [W],Equipment Sensible Heat Addition [W],Window Heat Addition [W],Interzone Air Transfer Heat Addition [W],Infiltration Heat Addition [W],Opaque Surface Conduction and Other Heat Addition [W],Equipment Sensible Heat Removal [W],Window Heat Removal [W],Interzone Air Transfer Heat Removal [W],Infiltration Heat Removal [W],Opaque Surface Conduction and Other Heat Removal [W]
,175785,12-JAN-07:03,62764.69,0.00,0.00,0.00,0.00,0.00,1327.44,1286.71,1871.57,0.00,0.00,0.00,0.00,0.00,-7102.44,0.00,-8506.39,-51641.58
,176293,12-JAN-07:03,50123.61,0.00,0.00,0.00,0.00,0.00,1049.21,1017.01,1479.29,0.00,0.00,0.00,0.00,0.00,-5797.15,0.00,-6723.29,-41148.67
,182393,12-JAN-07:03,39192.40,0.00,0.00,0.00,0.00,0.00,565.83,548.47,797.77,0.00,0.00,0.00,0.00,0.00,-5843.18,0.00,-3623.55,-31637.75
,Total Facility,12-JAN-07:03,152080.70,0.00,0.00,0.00,0.00,0.00,2942.49,2852.19,4148.63,0.00,0.00,0.00,0.00,0.00,-18742.76,0.00,-18853.24,-124428.00
1 Program Version:,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11
2 Tabular Output Report in Format: ,Comma
3 Building:,Buildings in b'Montreal'
4 Environment:,RUN PERIOD 1 ** Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270
5 ----------------------------------------------------------------------------------------------------
6 REPORT:,Annual Building Utility Performance Summary
7 FOR:,Entire Facility
8 Values gathered over 8760.00 hours
9 Site and Source Energy
10 ,,Total Energy [kWh],Energy Per Total Building Area [kWh/m2],Energy Per Conditioned Building Area [kWh/m2]
11 ,Total Site Energy,254015.03,821.95,821.95
12 ,Net Site Energy,254015.03,821.95,821.95
13 ,Total Source Energy,820655.39,2655.52,2655.52
14 ,Net Source Energy,820655.39,2655.52,2655.52
15 Site to Source Energy Conversion Factors
16 ,,Site=>Source Conversion Factor
17 ,Electricity,3.167
18 ,Natural Gas,1.084
19 ,District Cooling,1.056
20 ,District Heating,3.613
21 ,Steam,1.200
22 ,Gasoline,1.050
23 ,Diesel,1.050
24 ,Coal,1.050
25 ,Fuel Oil No 1,1.050
26 ,Fuel Oil No 2,1.050
27 ,Propane,1.050
28 ,Other Fuel 1,1.000
29 ,Other Fuel 2,1.000
30 Building Area
31 ,,Area [m2]
32 ,Total Building Area,309.04
33 ,Net Conditioned Building Area,309.04
34 ,Unconditioned Building Area,0.00
35 End Uses
36 ,,Electricity [kWh],Natural Gas [kWh],Gasoline [kWh],Diesel [kWh],Coal [kWh],Fuel Oil No 1 [kWh],Fuel Oil No 2 [kWh],Propane [kWh],Other Fuel 1 [kWh],Other Fuel 2 [kWh],District Cooling [kWh],District Heating [kWh],Water [m3]
37 ,Heating,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,114133.39,0.00
38 ,Cooling,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,32461.74,0.00,0.00
39 ,Interior Lighting,11659.74,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
40 ,Exterior Lighting,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
41 ,Interior Equipment,20063.83,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
42 ,Exterior Equipment,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
43 ,Fans,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
44 ,Pumps,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
45 ,Heat Rejection,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
46 ,Humidification,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
47 ,Heat Recovery,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
48 ,Water Systems,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,75696.33,1068.88
49 ,Refrigeration,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
50 ,Generators,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
51 ,,,,,,,,,,,,,,
52 ,Total End Uses,31723.57,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,32461.74,189829.73,1068.88
53 Note: District heat appears to be the principal heating source based on energy usage.
54 End Uses By Subcategory
55 ,,Subcategory,Electricity [kWh],Natural Gas [kWh],Gasoline [kWh],Diesel [kWh],Coal [kWh],Fuel Oil No 1 [kWh],Fuel Oil No 2 [kWh],Propane [kWh],Other Fuel 1 [kWh],Other Fuel 2 [kWh],District Cooling [kWh],District Heating [kWh],Water [m3]
56 ,Heating,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,114133.39,0.00
57 ,Cooling,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,32461.74,0.00,0.00
58 ,Interior Lighting,ELECTRIC EQUIPMENT#175785#GeneralLights,5260.06,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
59 ,,ELECTRIC EQUIPMENT#176293#GeneralLights,4157.54,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
60 ,,ELECTRIC EQUIPMENT#182393#GeneralLights,2242.14,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
61 ,Exterior Lighting,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
62 ,Interior Equipment,ELECTRIC EQUIPMENT#175785#InteriorEquipment,9051.40,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
63 ,,ELECTRIC EQUIPMENT#176293#InteriorEquipment,7154.20,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
64 ,,ELECTRIC EQUIPMENT#182393#InteriorEquipment,3858.22,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
65 ,Exterior Equipment,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
66 ,Fans,Ventilation (simple),0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
67 ,Pumps,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
68 ,Heat Rejection,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
69 ,Humidification,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
70 ,Heat Recovery,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
71 ,Water Systems,DHW 175785,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,34148.92,482.20
72 ,,DHW 176293,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,26991.20,381.13
73 ,,DHW 182393,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,14556.22,205.54
74 ,Refrigeration,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
75 ,Generators,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
76 Normalized Metrics
77 Utility Use Per Conditioned Floor Area
78 ,,Electricity Intensity [kWh/m2],Natural Gas Intensity [kWh/m2],Gasoline Intensity [kWh/m2],Diesel Intensity [kWh/m2],Coal Intensity [kWh/m2],Fuel Oil No 1 Intensity [kWh/m2],Fuel Oil No 2 Intensity [kWh/m2],Propane Intensity [kWh/m2],Other Fuel 1 Intensity [kWh/m2],Other Fuel 2 Intensity [kWh/m2],District Cooling Intensity [kWh/m2],District Heating Intensity [kWh/m2],Water Intensity [m3/m2]
79 ,Lighting,37.73,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
80 ,HVAC,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
81 ,Other,64.92,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
82 ,Total,102.65,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
83 Utility Use Per Total Floor Area
84 ,,Electricity Intensity [kWh/m2],Natural Gas Intensity [kWh/m2],Gasoline Intensity [kWh/m2],Diesel Intensity [kWh/m2],Coal Intensity [kWh/m2],Fuel Oil No 1 Intensity [kWh/m2],Fuel Oil No 2 Intensity [kWh/m2],Propane Intensity [kWh/m2],Other Fuel 1 Intensity [kWh/m2],Other Fuel 2 Intensity [kWh/m2],District Cooling Intensity [kWh/m2],District Heating Intensity [kWh/m2],Water Intensity [m3/m2]
85 ,Lighting,37.73,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
86 ,HVAC,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
87 ,Other,64.92,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
88 ,Total,102.65,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,105.04,614.26,3.46
89 Electric Loads Satisfied
90 ,,Electricity [kWh],Percent Electricity [%]
91 ,Fuel-Fired Power Generation,0.000,0.00
92 ,High Temperature Geothermal*,0.000,0.00
93 ,Photovoltaic Power,0.000,0.00
94 ,Wind Power,0.000,0.00
95 ,Power Conversion,0.000,0.00
96 ,Net Decrease in On-Site Storage,0.000,0.00
97 ,Total On-Site Electric Sources,0.000,0.00
98 ,,,
99 ,Electricity Coming From Utility,31723.568,100.00
100 ,Surplus Electricity Going To Utility,0.000,0.00
101 ,Net Electricity From Utility,31723.568,100.00
102 ,,,
103 ,Total On-Site and Utility Electric Sources,31723.568,100.00
104 ,Total Electricity End Uses,31723.568,100.00
105 On-Site Thermal Sources
106 ,,Heat [kWh],Percent Heat [%]
107 ,Water-Side Heat Recovery,0.00,
108 ,Air to Air Heat Recovery for Cooling,0.00,
109 ,Air to Air Heat Recovery for Heating,0.00,
110 ,High-Temperature Geothermal*,0.00,
111 ,Solar Water Thermal,0.00,
112 ,Solar Air Thermal,0.00,
113 ,Total On-Site Thermal Sources,0.00,
114 Water Source Summary
115 ,,Water [m3],Percent Water [%]
116 ,Rainwater Collection,0.00,0.00
117 ,Condensate Collection,0.00,0.00
118 ,Groundwater Well,0.00,0.00
119 ,Total On Site Water Sources,0.00,0.00
120 ,-,-,-
121 ,Initial Storage,0.00,0.00
122 ,Final Storage,0.00,0.00
123 ,Change in Storage,0.00,0.00
124 ,-,-,-
125 ,Water Supplied by Utility,1068.88,100.00
126 ,-,-,-
127 ,Total On Site, Change in Storage, and Utility Water Sources,1068.88,100.00
128 ,Total Water End Uses,1068.88,100.00
129 Setpoint Not Met Criteria
130 ,,Degrees [deltaC]
131 ,Tolerance for Zone Heating Setpoint Not Met Time,0.20
132 ,Tolerance for Zone Cooling Setpoint Not Met Time,0.20
133 Comfort and Setpoint Not Met Summary
134 ,,Facility [Hours]
135 ,Time Setpoint Not Met During Occupied Heating,0.00
136 ,Time Setpoint Not Met During Occupied Cooling,0.00
137 ,Time Not Comfortable Based on Simple ASHRAE 55-2004,5311.25
138 Note 1: An asterisk (*) indicates that the feature is not yet implemented.
139 ----------------------------------------------------------------------------------------------------
140 REPORT:,Input Verification and Results Summary
141 FOR:,Entire Facility
142 General
143 ,,Value
144 ,Program Version and Build,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11
145 ,RunPeriod,RUN PERIOD 1
146 ,Weather File,Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270
147 ,Latitude [deg],45.47
148 ,Longitude [deg],-73.8
149 ,Elevation [m],36.00
150 ,Time Zone,-5.0
151 ,North Axis Angle [deg],0.00
152 ,Rotation for Appendix G [deg],0.00
153 ,Hours Simulated [hrs],8760.00
154 ENVELOPE
155 Window-Wall Ratio
156 ,,Total,North (315 to 45 deg),East (45 to 135 deg),South (135 to 225 deg),West (225 to 315 deg)
157 ,Gross Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
158 ,Above Ground Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
159 ,Window Opening Area [m2],215.26,65.34,41.85,65.26,42.82
160 ,Gross Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
161 ,Above Ground Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
162 Conditioned Window-Wall Ratio
163 ,,Total,North (315 to 45 deg),East (45 to 135 deg),South (135 to 225 deg),West (225 to 315 deg)
164 ,Gross Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
165 ,Above Ground Wall Area [m2],1077.40,327.00,209.46,326.62,214.31
166 ,Window Opening Area [m2],215.26,65.34,41.85,65.26,42.82
167 ,Gross Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
168 ,Above Ground Window-Wall Ratio [%],19.98,19.98,19.98,19.98,19.98
169 Skylight-Roof Ratio
170 ,,Total
171 ,Gross Roof Area [m2],309.04
172 ,Skylight Area [m2],0.00
173 ,Skylight-Roof Ratio [%],0.00
174 PERFORMANCE
175 Zone Summary
176 ,,Area [m2],Conditioned (Y/N),Part of Total Floor Area (Y/N),Volume [m3],Multipliers,Above Ground Gross Wall Area [m2],Underground Gross Wall Area [m2],Window Glass Area [m2],Opening Area [m2],Lighting [W/m2],People [m2 per person],Plug and Process [W/m2]
177 ,175785,116.93,Yes,Yes,1403.17,1.00,410.07,0.00,81.93,81.93,22.0080,6.25,20.0073
178 ,176293,92.42,Yes,Yes,1109.06,1.00,326.92,0.00,65.32,65.32,22.0080,6.25,20.0073
179 ,182393,99.69,Yes,Yes,797.48,1.00,340.41,0.00,68.01,68.01,11.0040,12.50,10.0036
180 ,Total,309.04,,,3309.71,,1077.40,0.00,215.26,215.26,18.4585,7.45,16.7804
181 ,Conditioned Total,309.04,,,3309.71,,1077.40,0.00,215.26,215.26,18.4585,7.45,16.7804
182 ,Unconditioned Total,0.00,,,0.00,,0.00,0.00,0.00,0.00,,,
183 ,Not Part of Total,0.00,,,0.00,,0.00,0.00,0.00,0.00,,,
184 ----------------------------------------------------------------------------------------------------
185 REPORT:,Demand End Use Components Summary
186 FOR:,Entire Facility
187 End Uses
188 ,,Electricity [W],Natural Gas [W],Gasoline [W],Diesel [W],Coal [W],Fuel Oil No 1 [W],Fuel Oil No 2 [W],Propane [W],Other Fuel 1 [W],Other Fuel 2 [W],District Cooling [W],District Heating [W],Water [m3/s]
189 ,Time of Peak,01-JAN-19:15,-,-,-,-,-,-,-,-,-,20-JUL-16:30,04-FEB-07:15,10-AUG-16:15
190 ,Heating,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,72233.34,0.00
191 ,Cooling,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,45602.66,0.00,0.00
192 ,Interior Lighting,5133.93,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
193 ,Exterior Lighting,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
194 ,Interior Equipment,4667.21,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
195 ,Exterior Equipment,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
196 ,Fans,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
197 ,Pumps,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
198 ,Heat Rejection,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
199 ,Humidification,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
200 ,Heat Recovery,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
201 ,Water Systems,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,20682.68,0.00
202 ,Refrigeration,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
203 ,Generators,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
204 ,,,,,,,,,,,,,,
205 ,Total End Uses,9801.15,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,45602.66,92916.02,0.00
206 End Uses By Subcategory
207 ,,Subcategory,Electricity [W],Natural Gas [W],Gasoline [W],Diesel [W],Coal [W],Fuel Oil No 1 [W],Fuel Oil No 2 [W],Propane [W],Other Fuel 1 [W],Other Fuel 2 [W],District Cooling [W],District Heating [W],Water [m3/s]
208 ,Heating,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,72233.34,0.00
209 ,Cooling,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,45602.66,0.00,0.00
210 ,Interior Lighting,ELECTRIC EQUIPMENT#175785#GeneralLights,2316.07,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
211 ,,ELECTRIC EQUIPMENT#176293#GeneralLights,1830.62,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
212 ,,ELECTRIC EQUIPMENT#182393#GeneralLights,987.24,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
213 ,Exterior Lighting,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
214 ,Interior Equipment,ELECTRIC EQUIPMENT#175785#InteriorEquipment,2105.52,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
215 ,,ELECTRIC EQUIPMENT#176293#InteriorEquipment,1664.20,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
216 ,,ELECTRIC EQUIPMENT#182393#InteriorEquipment,897.49,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
217 ,Exterior Equipment,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
218 ,Fans,Ventilation (simple),0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
219 ,Pumps,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
220 ,Heat Rejection,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
221 ,Humidification,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
222 ,Heat Recovery,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
223 ,Water Systems,DHW 175785,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,9330.58,0.00
224 ,,DHW 176293,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,7374.87,0.00
225 ,,DHW 182393,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,3977.23,0.00
226 ,Refrigeration,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
227 ,Generators,General,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00,0.00
228 ----------------------------------------------------------------------------------------------------
229 REPORT:,Component Sizing Summary
230 FOR:,Entire Facility
231 ----------------------------------------------------------------------------------------------------
232 REPORT:,Adaptive Comfort Summary
233 FOR:,Entire Facility
234 Time Not Meeting the Adaptive Comfort Models during Occupied Hours
235 ,,ASHRAE55 90% Acceptability Limits [Hours],ASHRAE55 80% Acceptability Limits [Hours],CEN15251 Category I Acceptability Limits [Hours],CEN15251 Category II Acceptability Limits [Hours],CEN15251 Category III Acceptability Limits [Hours]
236 ----------------------------------------------------------------------------------------------------
237 REPORT:,Climatic Data Summary
238 FOR:,Entire Facility
239 SizingPeriod:DesignDay
240 ,,Maximum Dry Bulb [C],Daily Temperature Range [deltaC],Humidity Value,Humidity Type,Wind Speed [m/s],Wind Direction
241 ,None,,,,,,
242 Weather Statistics File
243 ,,Value
244 ,None,
245 ----------------------------------------------------------------------------------------------------
246 REPORT:,Envelope Summary
247 FOR:,Entire Facility
248 Opaque Exterior
249 ,,Construction,Reflectance,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Net Area [m2],Azimuth [deg],Tilt [deg],Cardinal Direction
250 ,FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A,1981_1990_6,0.40,0.644,0.713,79.35,63.50,89.98,90.00,E
251 ,3B6D9D89-A422-445A-B305-4E9D2F952782,1981_1990_6,0.40,0.644,0.713,1.88,1.50,270.07,90.00,W
252 ,9DCD5D84-78DF-4DA5-80C4-FAE17544226E,1981_1990_6,0.40,0.644,0.713,38.53,30.83,0.07,90.00,N
253 ,C8CD208F-797F-428F-94DC-277ADC9EF001,1981_1990_6,0.40,0.644,0.713,77.98,62.40,269.91,90.00,W
254 ,1B2839C9-4131-44CA-BD66-B4F56F1F1306,1981_1990_6,0.40,0.644,0.713,212.34,169.91,179.99,90.00,S
255 ,6ACF7617-7D20-4059-916F-A322696BF7D6,1981_1990_6,0.40,0.639,0.713,116.93,116.93,359.99,180.00,
256 ,C17F7386-D2BC-4D4A-B05A-E846AAABA4C3,1981_1990_6,0.40,0.649,0.713,116.93,116.93,0.13,0.00,
257 ,F7A66C0B-F3E1-46C4-9AFE-F040250343B2,1981_1990_6,0.40,0.644,0.713,76.55,61.25,89.98,90.00,E
258 ,673F9DDD-64F1-4F17-AD3B-320A0F77383B,1981_1990_6,0.40,0.644,0.713,173.82,139.09,0.13,90.00,N
259 ,F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC,1981_1990_6,0.40,0.644,0.713,76.55,61.25,270.04,90.00,W
260 ,7F337640-75A0-437B-8C4F-6EC6A6B647DF,1981_1990_6,0.40,0.639,0.713,92.42,92.42,0.13,180.00,
261 ,69118BC1-AC76-440F-9C42-F25C672CE2F6,1981_1990_6,0.40,0.649,0.713,92.42,92.42,0.13,0.00,
262 ,79EAC576-A260-4143-83B0-32CF204BBE7B,1981_1990_6,0.40,0.644,0.713,3.22,2.58,91.08,90.00,E
263 ,A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0,1981_1990_6,0.40,0.644,0.713,106.72,85.40,2.33,90.00,N
264 ,EA75342E-1CCC-4A1D-9AE3-56FFEA395133,1981_1990_6,0.40,0.644,0.713,7.94,6.35,1.96,90.00,N
265 ,48A796FD-5D1F-463D-9357-C9E2182110A4,1981_1990_6,0.40,0.644,0.713,57.91,46.34,270.12,90.00,W
266 ,13EA4940-36E8-4E27-87EB-55C74E690355,1981_1990_6,0.40,0.644,0.713,114.28,91.44,180.13,90.00,S
267 ,958929BB-ACD4-4629-AB9F-B6984E758263,1981_1990_6,0.40,0.644,0.713,50.34,40.28,90.40,90.00,E
268 ,6E6AFC12-5493-40C0-B7E5-DA42F550F2B5,1981_1990_6,0.40,0.639,0.713,99.69,99.69,270.40,180.00,
269 ,0B62F37E-EDEC-4014-A6D4-01279F8A3493,1981_1990_6,0.40,0.649,0.713,99.69,99.69,91.08,0.00,
270 Opaque Interior
271 ,,Construction,Reflectance,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Net Area [m2],Azimuth [deg],Tilt [deg],Cardinal Direction
272 ,4FA50238-068D-4E20-A2BA-8A5A0A93B796,1981_1990_6,0.40,0.609,0.713,173.90,173.90,0.13,90.00,N
273 ,DAD33850-1CAC-42D6-BABA-76AA1E6E4A4D,1981_1990_6,0.40,0.609,0.713,173.90,173.90,180.13,90.00,S
274 Exterior Fenestration
275 ,,Construction,Glass Area [m2],Frame Area [m2],Divider Area [m2],Area of One Opening [m2],Area of Multiplied Openings [m2],Glass U-Factor [W/m2-K],Glass SHGC,Glass Visible Transmittance,Frame Conductance [W/m2-K],Divider Conductance [W/m2-K],Shade Control,Parent Surface,Azimuth [deg],Tilt [deg],Cardinal Direction
276 ,FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A WINDOW,WINDOW_CONSTRUCTION_1,15.85,0.00,0.00,15.85,15.85,2.954,0.391,0.305,,,No,FF11F32E-61F9-4CEB-A28E-E9D8A2D21D7A,89.98,90.00,E
277 ,3B6D9D89-A422-445A-B305-4E9D2F952782 WINDOW,WINDOW_CONSTRUCTION_1,0.37,0.00,0.00,0.37,0.37,2.954,0.391,0.305,,,No,3B6D9D89-A422-445A-B305-4E9D2F952782,270.07,90.00,W
278 ,9DCD5D84-78DF-4DA5-80C4-FAE17544226E WINDOW,WINDOW_CONSTRUCTION_1,7.70,0.00,0.00,7.70,7.70,2.954,0.391,0.305,,,No,9DCD5D84-78DF-4DA5-80C4-FAE17544226E,0.07,90.00,N
279 ,C8CD208F-797F-428F-94DC-277ADC9EF001 WINDOW,WINDOW_CONSTRUCTION_1,15.58,0.00,0.00,15.58,15.58,2.954,0.391,0.305,,,No,C8CD208F-797F-428F-94DC-277ADC9EF001,269.91,90.00,W
280 ,1B2839C9-4131-44CA-BD66-B4F56F1F1306 WINDOW,WINDOW_CONSTRUCTION_1,42.43,0.00,0.00,42.43,42.43,2.954,0.391,0.305,,,No,1B2839C9-4131-44CA-BD66-B4F56F1F1306,179.99,90.00,S
281 ,F7A66C0B-F3E1-46C4-9AFE-F040250343B2 WINDOW,WINDOW_CONSTRUCTION_1,15.29,0.00,0.00,15.29,15.29,2.954,0.391,0.305,,,No,F7A66C0B-F3E1-46C4-9AFE-F040250343B2,89.98,90.00,E
282 ,673F9DDD-64F1-4F17-AD3B-320A0F77383B WINDOW,WINDOW_CONSTRUCTION_1,34.73,0.00,0.00,34.73,34.73,2.954,0.391,0.305,,,No,673F9DDD-64F1-4F17-AD3B-320A0F77383B,0.13,90.00,N
283 ,F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC WINDOW,WINDOW_CONSTRUCTION_1,15.29,0.00,0.00,15.29,15.29,2.954,0.391,0.305,,,No,F0E8F86A-0DC1-4E31-B33E-3562FB8B2BDC,270.04,90.00,W
284 ,79EAC576-A260-4143-83B0-32CF204BBE7B WINDOW,WINDOW_CONSTRUCTION_1,0.64,0.00,0.00,0.64,0.64,2.954,0.391,0.305,,,No,79EAC576-A260-4143-83B0-32CF204BBE7B,91.08,90.00,E
285 ,A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0 WINDOW,WINDOW_CONSTRUCTION_1,21.32,0.00,0.00,21.32,21.32,2.954,0.391,0.305,,,No,A43B5153-DA22-4FD3-A4FC-ED018BE3F5F0,2.33,90.00,N
286 ,EA75342E-1CCC-4A1D-9AE3-56FFEA395133 WINDOW,WINDOW_CONSTRUCTION_1,1.59,0.00,0.00,1.59,1.59,2.954,0.391,0.305,,,No,EA75342E-1CCC-4A1D-9AE3-56FFEA395133,1.96,90.00,N
287 ,48A796FD-5D1F-463D-9357-C9E2182110A4 WINDOW,WINDOW_CONSTRUCTION_1,11.57,0.00,0.00,11.57,11.57,2.954,0.391,0.305,,,No,48A796FD-5D1F-463D-9357-C9E2182110A4,270.12,90.00,W
288 ,13EA4940-36E8-4E27-87EB-55C74E690355 WINDOW,WINDOW_CONSTRUCTION_1,22.83,0.00,0.00,22.83,22.83,2.954,0.391,0.305,,,No,13EA4940-36E8-4E27-87EB-55C74E690355,180.13,90.00,S
289 ,958929BB-ACD4-4629-AB9F-B6984E758263 WINDOW,WINDOW_CONSTRUCTION_1,10.06,0.00,0.00,10.06,10.06,2.954,0.391,0.305,,,No,958929BB-ACD4-4629-AB9F-B6984E758263,90.40,90.00,E
290 ,Total or Average,,,,,,215.26,2.954,0.391,0.305,,,,,,,
291 ,North Total or Average,,,,,,65.34,2.954,0.391,0.305,,,,,,,
292 ,Non-North Total or Average,,,,,,149.93,2.954,0.391,0.305,,,,,,,
293 Interior Fenestration
294 ,,Construction,Area of One Opening [m2],Area of Openings [m2],Glass U-Factor [W/m2-K],Glass SHGC,Glass Visible Transmittance,Parent Surface
295 ,Total or Average,,,0.00,-,-,-,
296 Exterior Door
297 ,,Construction,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Parent Surface
298 ,None,,,,,
299 Interior Door
300 ,,Construction,U-Factor with Film [W/m2-K],U-Factor no Film [W/m2-K],Gross Area [m2],Parent Surface
301 ,None,,,,,
302 ----------------------------------------------------------------------------------------------------
303 REPORT:,Lighting Summary
304 FOR:,Entire Facility
305 Interior Lighting
306 ,,Zone,Lighting Power Density [W/m2],Zone Area [m2],Total Power [W],End Use Subcategory,Schedule Name,Scheduled Hours/Week [hr],Hours/Week > 1% [hr],Full Load Hours/Week [hr],Return Air Fraction,Conditioned (Y/N),Consumption [kWh]
307 ,175785_LIGHTS,175785,22.0080,116.93,2573.42,ELECTRIC EQUIPMENT#175785#GeneralLights,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,39.20,63.00,39.20,0.0000,Y,5259.87
308 ,176293_LIGHTS,176293,22.0080,92.42,2034.02,ELECTRIC EQUIPMENT#176293#GeneralLights,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,39.20,63.00,39.20,0.0000,Y,4157.39
309 ,182393_LIGHTS,182393,11.0040,99.69,1096.94,ELECTRIC EQUIPMENT#182393#GeneralLights,LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING,39.20,63.00,39.20,0.0000,Y,2242.06
310 ,Interior Lighting Total,,18.4585,309.04,5704.37,,,,,,,,11659.32
311 Daylighting
312 ,,Zone,Control Name,Daylighting Method,Control Type,Fraction Controlled,Lighting Installed in Zone [W],Lighting Controlled [W]
313 ,None,,,,,,,
314 Exterior Lighting
315 ,,Total Watts,Astronomical Clock/Schedule,Schedule Name,Scheduled Hours/Week [hr],Hours/Week > 1% [hr],Full Load Hours/Week [hr],Consumption [kWh]
316 ,Exterior Lighting Total,0.00,,,,,,0.00
317 ----------------------------------------------------------------------------------------------------
318 REPORT:,Equipment Summary
319 FOR:,Entire Facility
320 Central Plant
321 ,,Type,Nominal Capacity [W],Nominal Efficiency [W/W],IPLV in SI Units [W/W],IPLV in IP Units [Btu/W-h]
322 ,None,,,,,
323 Cooling Coils
324 ,,Type,Design Coil Load [W],Nominal Total Capacity [W],Nominal Sensible Capacity [W],Nominal Latent Capacity [W],Nominal Sensible Heat Ratio,Nominal Efficiency [W/W],Nominal Coil UA Value [W/C],Nominal Coil Surface Area [m2]
325 ,None,,,,,,,,,
326 DX Cooling Coils
327 ,,DX Cooling Coil Type,Standard Rated Net Cooling Capacity [W],Standard Rated Net COP [W/W],EER [Btu/W-h],SEER User [Btu/W-h],SEER Standard [Btu/W-h],IEER [Btu/W-h]
328 ,None,,,,,,,
329 DX Cooling Coil ASHRAE 127 Standard Ratings Report
330 ,,DX Cooling Coil Type,Rated Net Cooling Capacity Test A [W],Rated Electric Power Test A [W],Rated Net Cooling Capacity Test B [W],Rated Electric Power Test B [W],Rated Net Cooling Capacity Test C [W],Rated Electric Power Test C [W],Rated Net Cooling Capacity Test D [W],Rated Electric Power Test D [W]
331 ,None,,,,,,,,,
332 DX Heating Coils
333 ,,DX Heating Coil Type,High Temperature Heating (net) Rating Capacity [W],Low Temperature Heating (net) Rating Capacity [W],HSPF [Btu/W-h],Region Number
334 ,None,,,,,
335 Heating Coils
336 ,,Type,Design Coil Load [W],Nominal Total Capacity [W],Nominal Efficiency [W/W]
337 ,None,,,,
338 Fans
339 ,,Type,Total Efficiency [W/W],Delta Pressure [pa],Max Air Flow Rate [m3/s],Rated Electricity Rate [W],Rated Power Per Max Air Flow Rate [W-s/m3],Motor Heat In Air Fraction,Fan Energy Index,End Use Subcategory,Design Day Name for Fan Sizing Peak,Date/Time for Fan Sizing Peak
340 ,None,,,,,,,,,,,
341 Pumps
342 ,,Type,Control,Head [pa],Water Flow [m3/s],Electricity Rate [W],Power Per Water Flow Rate [W-s/m3],Motor Efficiency [W/W],End Use Subcategory
343 ,None,,,,,,,,
344 Service Water Heating
345 ,,Type,Storage Volume [m3],Input [W],Thermal Efficiency [W/W],Recovery Efficiency [W/W],Energy Factor
346 ,None,,,,,,
347 ----------------------------------------------------------------------------------------------------
348 REPORT:,HVAC Sizing Summary
349 FOR:,Entire Facility
350 Zone Sensible Cooling
351 ,,Calculated Design Load [W],User Design Load [W],User Design Load per Area [W/m2],Calculated Design Air Flow [m3/s],User Design Air Flow [m3/s],Design Day Name,Date/Time Of Peak {TIMESTAMP},Thermostat Setpoint Temperature at Peak Load [C],Indoor Temperature at Peak Load [C],Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Outdoor Temperature at Peak Load [C],Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Minimum Outdoor Air Flow Rate [m3/s],Heat Gain Rate from DOAS [W]
352 ,None,,,,,,,,,,,,,,
353 The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.
354 Zone Sensible Heating
355 ,,Calculated Design Load [W],User Design Load [W],User Design Load per Area [W/m2],Calculated Design Air Flow [m3/s],User Design Air Flow [m3/s],Design Day Name,Date/Time Of Peak {TIMESTAMP},Thermostat Setpoint Temperature at Peak Load [C],Indoor Temperature at Peak Load [C],Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Outdoor Temperature at Peak Load [C],Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir],Minimum Outdoor Air Flow Rate [m3/s],Heat Gain Rate from DOAS [W]
356 ,None,,,,,,,,,,,,,,
357 The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.
358 System Design Air Flow Rates
359 ,,Calculated cooling [m3/s],User cooling [m3/s],Calculated heating [m3/s],User heating [m3/s],Adjusted cooling [m3/s],Adjusted heating [m3/s],Adjusted main [m3/s],Calculated Heating Air Flow Ratio [],User Heating Air Flow Ratio []
360 ,None,,,,,,,,,
361 Plant Loop Coincident Design Fluid Flow Rate Adjustments
362 ,,Previous Design Volume Flow Rate [m3/s],Algorithm Volume Flow Rate [m3/s],Coincident Design Volume Flow Rate [m3/s],Coincident Size Adjusted,Peak Sizing Period Name,Peak Day into Period {TIMESTAMP}[day],Peak Hour Of Day {TIMESTAMP}[hr],Peak Step Start Minute {TIMESTAMP}[min]
363 ,None,,,,,,,,
364 Coil Sizing Summary
365 ,,Coil Type,HVAC Type,HVAC Name,Coil Final Gross Total Capacity [W],Coil Final Gross Sensible Capacity [W],Coil Final Reference Air Volume Flow Rate [m3/s],Coil Final Reference Plant Fluid Volume Flow Rate [m3/s],Coil U-value Times Area Value [W/K],Design Day Name at Sensible Ideal Loads Peak,Date/Time at Sensible Ideal Loads Peak,Design Day Name at Air Flow Ideal Loads Peak,Date/Time at Air Flow Ideal Loads Peak,Coil Total Capacity at Ideal Loads Peak [W],Coil Sensible Capacity at Ideal Loads Peak [W],Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s],Coil Entering Air Drybulb at Ideal Loads Peak [C],Coil Entering Air Wetbulb at Ideal Loads Peak [C],Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Coil Leaving Air Drybulb at Ideal Loads Peak [C],Coil Leaving Air Wetbulb at Ideal Loads Peak [C],Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Outdoor Air Drybulb at Ideal Loads Peak [C],Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Outdoor Air Wetbulb at Ideal Loads Peak [C],Outdoor Air Flow Percentage at Ideal Loads Peak [%],Zone Air Drybulb at Ideal Loads Peak [C],Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir],Zone Air Relative Humidity at Ideal Loads Peak [%],Zone Sensible Heat Gain at Ideal Loads Peak [W],Zone Latent Heat Gain at Ideal Loads Peak [W],Coil Total Capacity at Rating Conditions [W],Coil Sensible Capacity at Rating Conditions [W]
366 ,None,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
367 ----------------------------------------------------------------------------------------------------
368 REPORT:,System Summary
369 FOR:,Entire Facility
370 Economizer
371 ,,High Limit Shutoff Control,Minimum Outdoor Air [m3/s],Maximum Outdoor Air [m3/s],Return Air Temp Limit,Return Air Enthalpy Limit,Outdoor Air Temperature Limit [C],Outdoor Air Enthalpy Limit [C]
372 ,None,,,,,,,
373 Demand Controlled Ventilation using Controller:MechanicalVentilation
374 ,,Controller:MechanicalVentilation Name,Outdoor Air Per Person [m3/s-person],Outdoor Air Per Area [m3/s-m2],Outdoor Air Per Zone [m3/s],Outdoor Air ACH [ach],Outdoor Air Method,Outdoor Air Schedule Name,Air Distribution Effectiveness in Cooling Mode,Air Distribution Effectiveness in Heating Mode,Air Distribution Effectiveness Schedule Name
375 ,None,,,,,,,,,,
376 Time Not Comfortable Based on Simple ASHRAE 55-2004
377 ,,Winter Clothes [hr],Summer Clothes [hr],Summer or Winter Clothes [hr]
378 ,175785,6488.00,6546.00,4705.50
379 ,176293,6574.50,6807.50,5004.50
380 ,182393,6624.75,6733.50,5006.75
381 ,Facility,7106.25,7011.75,5311.25
382 Aggregated over the RunPeriods for Weather
383 Time Setpoint Not Met
384 ,,During Heating [hr],During Cooling [hr],During Occupied Heating [hr],During Occupied Cooling [hr]
385 ,175785,0.00,0.00,0.00,0.00
386 ,176293,0.00,0.00,0.00,0.00
387 ,182393,0.00,0.00,0.00,0.00
388 ,Facility,0.00,0.00,0.00,0.00
389 Aggregated over the RunPeriods for Weather
390 ----------------------------------------------------------------------------------------------------
391 REPORT:,Outdoor Air Summary
392 FOR:,Entire Facility
393 Average Outdoor Air During Occupied Hours
394 ,,Average Number of Occupants,Nominal Number of Occupants,Zone Volume [m3],Mechanical Ventilation [ach],Infiltration [ach],AFN Infiltration [ach],Simple Ventilation [ach]
395 ,175785,12.66,18.72,1403.17,0.000,0.000,0.000,0.387
396 ,176293,10.01,14.79,1109.06,0.000,0.000,0.000,0.387
397 ,182393,5.40,7.98,797.48,0.000,0.000,0.000,0.290
398 Values shown for a single zone without multipliers
399 Minimum Outdoor Air During Occupied Hours
400 ,,Average Number of Occupants,Nominal Number of Occupants,Zone Volume [m3],Mechanical Ventilation [ach],Infiltration [ach],AFN Infiltration [ach],Simple Ventilation [ach]
401 ,175785,12.66,18.72,1403.17,0.000,0.000,0.000,0.007
402 ,176293,10.01,14.79,1109.06,0.000,0.000,0.000,0.007
403 ,182393,5.40,7.98,797.48,0.000,0.000,0.000,0.005
404 Values shown for a single zone without multipliers
405 ----------------------------------------------------------------------------------------------------
406 REPORT:,Object Count Summary
407 FOR:,Entire Facility
408 Surfaces by Class
409 ,,Total,Outdoors
410 ,Wall,16,14
411 ,Floor,3,3
412 ,Roof,3,3
413 ,Internal Mass,0,0
414 ,Building Detached Shading,0,0
415 ,Fixed Detached Shading,0,0
416 ,Window,14,14
417 ,Door,0,0
418 ,Glass Door,0,0
419 ,Shading,0,0
420 ,Overhang,0,0
421 ,Fin,0,0
422 ,Tubular Daylighting Device Dome,0,0
423 ,Tubular Daylighting Device Diffuser,0,0
424 HVAC
425 ,,Count
426 ,HVAC Air Loops,0
427 ,Conditioned Zones,3
428 ,Unconditioned Zones,0
429 ,Supply Plenums,0
430 ,Return Plenums,0
431 Input Fields
432 ,,Count
433 ,IDF Objects,113
434 ,Defaulted Fields,8
435 ,Fields with Defaults,401
436 ,Autosized Fields,0
437 ,Autosizable Fields,12
438 ,Autocalculated Fields,81
439 ,Autocalculatable Fields,84
440 ----------------------------------------------------------------------------------------------------
441 REPORT:,Sensible Heat Gain Summary
442 FOR:,Entire Facility
443 Annual Building Sensible Heat Gain Components
444 ,,HVAC Zone Eq & Other Sensible Air Heating [kWh],HVAC Zone Eq & Other Sensible Air Cooling [kWh],HVAC Terminal Unit Sensible Air Heating [kWh],HVAC Terminal Unit Sensible Air Cooling [kWh],HVAC Input Heated Surface Heating [kWh],HVAC Input Cooled Surface Cooling [kWh],People Sensible Heat Addition [kWh],Lights Sensible Heat Addition [kWh],Equipment Sensible Heat Addition [kWh],Window Heat Addition [kWh],Interzone Air Transfer Heat Addition [kWh],Infiltration Heat Addition [kWh],Opaque Surface Conduction and Other Heat Addition [kWh],Equipment Sensible Heat Removal [kWh],Window Heat Removal [kWh],Interzone Air Transfer Heat Removal [kWh],Infiltration Heat Removal [kWh],Opaque Surface Conduction and Other Heat Removal [kWh]
445 ,175785,43048.351,-12346.47,0.000,0.000,0.000,0.000,9408.890,5260.065,9051.411,14802.112,0.000,161.085,0.000,0.000,-17395.07,0.000,-25721.02,-26269.36
446 ,176293,38609.040,-7666.35,0.000,0.000,0.000,0.000,7449.341,4157.541,7154.210,7096.867,0.000,127.321,0.000,0.000,-14980.01,0.000,-20253.67,-21694.29
447 ,182393,32346.619,-7050.46,0.000,0.000,0.000,0.000,4038.987,2242.140,3858.228,10037.769,0.000,69.058,0.000,0.000,-14033.41,0.000,-10884.82,-20624.10
448 ,Total Facility,114004.011,-27063.27,0.000,0.000,0.000,0.000,20897.218,11659.746,20063.848,31936.748,0.000,357.465,0.000,0.000,-46408.49,0.000,-56859.52,-68587.75
449 Peak Cooling Sensible Heat Gain Components
450 ,,Time of Peak {TIMESTAMP},HVAC Zone Eq & Other Sensible Air Heating [W],HVAC Zone Eq & Other Sensible Air Cooling [W],HVAC Terminal Unit Sensible Air Heating [W],HVAC Terminal Unit Sensible Air Cooling [W],HVAC Input Heated Surface Heating [W],HVAC Input Cooled Surface Cooling [W],People Sensible Heat Addition [W],Lights Sensible Heat Addition [W],Equipment Sensible Heat Addition [W],Window Heat Addition [W],Interzone Air Transfer Heat Addition [W],Infiltration Heat Addition [W],Opaque Surface Conduction and Other Heat Addition [W],Equipment Sensible Heat Removal [W],Window Heat Removal [W],Interzone Air Transfer Heat Removal [W],Infiltration Heat Removal [W],Opaque Surface Conduction and Other Heat Removal [W]
451 ,175785,15-AUG-14:00,0.00,-17068.90,0.00,0.00,0.00,0.00,410.61,0.00,935.79,11320.00,0.00,1194.62,3207.88,0.00,-0.00,0.00,0.00,0.00
452 ,176293,19-JUL-18:30,0.00,-11505.90,0.00,0.00,0.00,0.00,973.64,0.00,1664.20,6601.36,0.00,713.40,1553.30,0.00,-0.00,0.00,0.00,0.00
453 ,182393,15-AUG-14:00,0.00,-11080.13,0.00,0.00,0.00,0.00,175.03,0.00,398.89,7757.96,0.00,510.12,2238.15,0.00,-0.00,0.00,0.00,0.00
454 ,Total Facility,15-AUG-14:30,0.00,-37585.08,0.00,0.00,0.00,0.00,910.18,0.00,2074.32,23736.81,0.00,2647.74,8216.03,0.00,0.00,0.00,0.00,0.00
455 Peak Heating Sensible Heat Gain Components
456 ,,Time of Peak {TIMESTAMP},HVAC Zone Eq & Other Sensible Air Heating [W],HVAC Zone Eq & Other Sensible Air Cooling [W],HVAC Terminal Unit Sensible Air Heating [W],HVAC Terminal Unit Sensible Air Cooling [W],HVAC Input Heated Surface Heating [W],HVAC Input Cooled Surface Cooling [W],People Sensible Heat Addition [W],Lights Sensible Heat Addition [W],Equipment Sensible Heat Addition [W],Window Heat Addition [W],Interzone Air Transfer Heat Addition [W],Infiltration Heat Addition [W],Opaque Surface Conduction and Other Heat Addition [W],Equipment Sensible Heat Removal [W],Window Heat Removal [W],Interzone Air Transfer Heat Removal [W],Infiltration Heat Removal [W],Opaque Surface Conduction and Other Heat Removal [W]
457 ,175785,12-JAN-07:03,62764.69,0.00,0.00,0.00,0.00,0.00,1327.44,1286.71,1871.57,0.00,0.00,0.00,0.00,0.00,-7102.44,0.00,-8506.39,-51641.58
458 ,176293,12-JAN-07:03,50123.61,0.00,0.00,0.00,0.00,0.00,1049.21,1017.01,1479.29,0.00,0.00,0.00,0.00,0.00,-5797.15,0.00,-6723.29,-41148.67
459 ,182393,12-JAN-07:03,39192.40,0.00,0.00,0.00,0.00,0.00,565.83,548.47,797.77,0.00,0.00,0.00,0.00,0.00,-5843.18,0.00,-3623.55,-31637.75
460 ,Total Facility,12-JAN-07:03,152080.70,0.00,0.00,0.00,0.00,0.00,2942.49,2852.19,4148.63,0.00,0.00,0.00,0.00,0.00,-18742.76,0.00,-18853.24,-124428.00

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

View File

@ -12,8 +12,8 @@ class SystemSimulation:
def __init__(self, building): def __init__(self, building):
self.building = building self.building = building
self.energy_systems = building.energy_systems self.energy_systems = building.energy_systems
self.heating_demand = building.heating_demand[cte.HOUR] self.heating_demand = [0] + building.heating_demand[cte.HOUR]
self.cooling_demand = building.cooling_demand self.cooling_demand = [0] + building.cooling_demand[cte.HOUR]
self.dhw_demand = building.domestic_hot_water_heat_demand self.dhw_demand = building.domestic_hot_water_heat_demand
self.T_out = building.external_temperature[cte.HOUR] self.T_out = building.external_temperature[cte.HOUR]
self.maximum_heating_demand = building.heating_peak_load[cte.YEAR][0] self.maximum_heating_demand = building.heating_peak_load[cte.YEAR][0]
@ -23,13 +23,11 @@ class SystemSimulation:
def archetype1(self): def archetype1(self):
out_path = (Path(__file__).parent / 'out_files') out_path = (Path(__file__).parent / 'out_files')
T, T_sup, T_ret, m_ch, m_dis, q_hp, q_aux = [0] * len(self.heating_demand), [0] * len( T, T_sup, T_ret, m_ch, m_dis, q_hp, q_aux = [0] * (len(self.heating_demand) + 1), [0] * (len(self.heating_demand) + 1), [0] * (len(self.heating_demand) + 1), [0] * (len(self.heating_demand) + 1), [0] * (len(self.heating_demand) + 1), [0] * (len(self.heating_demand) + 1), [0] * (len(self.heating_demand) + 1)
self.heating_demand), [0] * len(self.heating_demand), [0] * len(self.heating_demand), [0] * len( hp_electricity: List[float] = [0.0] * (len(self.heating_demand) + 1)
self.heating_demand), [0] * len(self.heating_demand), [0] * len(self.heating_demand) aux_fuel: List[float] = [0.0] * (len(self.heating_demand) + 1)
hp_electricity: List[float] = [0.0] * len(self.heating_demand) heating_consumption: List[float] = [0.0] * (len(self.heating_demand) + 1)
aux_fuel: List[float] = [0.0] * len(self.heating_demand) boiler_consumption: List[float] = [0.0] * (len(self.heating_demand) + 1)
heating_consumption: List[float] = [0.0] * len(self.heating_demand)
boiler_consumption: List[float] = [0.0] * len(self.heating_demand)
T[0], dt = 25, 3600 # Assuming dt is defined somewhere T[0], dt = 25, 3600 # Assuming dt is defined somewhere
ua, v, hp_cap, hp_efficiency, boiler_efficiency = 0, 0, 0, 0, 0 ua, v, hp_cap, hp_efficiency, boiler_efficiency = 0, 0, 0, 0, 0
for energy_system in self.energy_systems: for energy_system in self.energy_systems:
@ -91,12 +89,12 @@ class SystemSimulation:
aux_fuel[i + 1] = (q_aux[i + 1] * dt) / 50e6 aux_fuel[i + 1] = (q_aux[i + 1] * dt) / 50e6
boiler_consumption[i + 1] = q_aux[i + 1] / boiler_efficiency boiler_consumption[i + 1] = q_aux[i + 1] / boiler_efficiency
heating_consumption[i + 1] = boiler_consumption[i + 1] + hp_electricity[i + 1] heating_consumption[i + 1] = boiler_consumption[i + 1] + hp_electricity[i + 1]
data = list(zip(T, T_sup, T_ret, m_ch, m_dis, q_hp, hp_electricity, aux_fuel, q_aux, self.heating_demand)) data = list(zip(T, T_sup, T_ret, m_ch, m_dis, q_hp, hp_electricity, aux_fuel, q_aux, self.heating_demand, self.cooling_demand))
file_name = f'simulation_results_{self.name}.csv' file_name = f'simulation_results_{self.name}.csv'
with open(out_path / file_name, 'w', newline='') as csvfile: with open(out_path / file_name, 'w', newline='') as csvfile:
output_file = csv.writer(csvfile) output_file = csv.writer(csvfile)
# Write header # Write header
output_file.writerow(['T', 'T_sup', 'T_ret', 'm_ch', 'm_dis', 'q_hp', 'hp_electricity', 'aux_fuel', 'q_aux', 'heating_demand']) output_file.writerow(['T', 'T_sup', 'T_ret', 'm_ch', 'm_dis', 'q_hp', 'hp_electricity', 'aux_fuel', 'q_aux', 'heating_demand', 'cooling_demand'])
# Write data # Write data
output_file.writerows(data) output_file.writerows(data)
return heating_consumption, hp_electricity, boiler_consumption return heating_consumption, hp_electricity, boiler_consumption