modifications in the systems catalog file

This commit is contained in:
Pilar Monsalvete 2023-04-28 12:11:48 -04:00
parent 688198a3fb
commit 42c39e771c

View File

@ -23,39 +23,43 @@
<storage>true</storage> <storage>true</storage>
</equipment> </equipment>
<equipment id="3" type="furnace" fuel_type="gas"> <equipment id="3" type="furnace" fuel_type="gas">
<name>Fuel-fired furnace</name> <name>Fuel-fired furnace and fuel boiler for acs</name>
<demands> <demands>
<demand>heating</demand> <demand>heating</demand>
</demands> <demand>domestic_hot_water</demand>
</demands>
<heating_efficiency>0.85</heating_efficiency> <heating_efficiency>0.85</heating_efficiency>
<distribution_heat_losses units="%">25</distribution_heat_losses> <distribution_heat_losses units="%">25</distribution_heat_losses>
<distribution_consumption units="%">5</distribution_consumption> <distribution_consumption units="%">NEEDED VALUE</distribution_consumption>
<storage>false</storage> <storage>false</storage>
</equipment> </equipment>
<equipment id="4" type="furnace" fuel_type="electricity"> <equipment id="4" type="furnace" fuel_type="electricity">
<name>Electrical resistance furnace</name> <name>Electrical resistance furnace and electrical boiler for acs</name>
<demands> <demands>
<demand>heating</demand> <demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands> </demands>
<heating_efficiency>1</heating_efficiency> <heating_efficiency>1</heating_efficiency>
<distribution_heat_losses units="%">25</distribution_heat_losses> <distribution_heat_losses units="%">25</distribution_heat_losses>
<distribution_consumption units="%">5</distribution_consumption> <distribution_consumption units="%">NEEDED VALUE</distribution_consumption>
<storage>false</storage> <storage>false</storage>
</equipment> </equipment>
<equipment id="5" type="baseboard" fuel_type="gas"> <equipment id="5" type="baseboard" fuel_type="gas">
<name>Baseboards: hydronic with fuel boiler</name> <name>Baseboards: hydronic with fuel boiler</name>
<demands> <demands>
<demand>heating</demand> <demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands> </demands>
<heating_efficiency>0.85</heating_efficiency> <heating_efficiency>0.85</heating_efficiency>
<distribution_heat_losses units="%">10</distribution_heat_losses> <distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption units="%">5</distribution_consumption> <distribution_consumption units="%">2</distribution_consumption>
<storage>false</storage> <storage>false</storage>
</equipment> </equipment>
<equipment id="6" type="baseboard" fuel_type="electricity"> <equipment id="6" type="baseboard" fuel_type="electricity">
<name>Electrical baseboards</name> <name>Electrical baseboards and electrical boiler for acs</name>
<demands> <demands>
<demand>heating</demand> <demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands> </demands>
<heating_efficiency>1</heating_efficiency> <heating_efficiency>1</heating_efficiency>
<distribution_heat_losses units="%">0</distribution_heat_losses> <distribution_heat_losses units="%">0</distribution_heat_losses>
@ -69,7 +73,7 @@
</demands> </demands>
<cooling_efficiency>3.23</cooling_efficiency> <cooling_efficiency>3.23</cooling_efficiency>
<distribution_heat_losses units="%">0</distribution_heat_losses> <distribution_heat_losses units="%">0</distribution_heat_losses>
<distribution_consumption units="%">5</distribution_consumption> <distribution_consumption units="%">NEEDED VALUE</distribution_consumption>
<storage>false</storage> <storage>false</storage>
</equipment> </equipment>
<equipment id="8" type="cooler" fuel_type="electricity"> <equipment id="8" type="cooler" fuel_type="electricity">
@ -89,7 +93,7 @@
</demands> </demands>
<cooling_efficiency>3.23</cooling_efficiency> <cooling_efficiency>3.23</cooling_efficiency>
<distribution_heat_losses units="%">0</distribution_heat_losses> <distribution_heat_losses units="%">0</distribution_heat_losses>
<distribution_consumption units="%">5</distribution_consumption> <distribution_consumption units="%">NEEDED VALUE</distribution_consumption>
<storage>false</storage> <storage>false</storage>
</equipment> </equipment>
<equipment id="10" type="electricity generator" fuel_type="renewable"> <equipment id="10" type="electricity generator" fuel_type="renewable">
@ -108,6 +112,13 @@
<equipment_id>7</equipment_id> <equipment_id>7</equipment_id>
</equipments> </equipments>
</system> </system>
<system name="system 1 gas pv">
<equipments>
<equipment_id>1</equipment_id>
<equipment_id>7</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 1 electricity"> <system name="system 1 electricity">
<equipments> <equipments>
<equipment_id>2</equipment_id> <equipment_id>2</equipment_id>
@ -121,5 +132,94 @@
<equipment_id>10</equipment_id> <equipment_id>10</equipment_id>
</equipments> </equipments>
</system> </system>
<system name="system 2 gas">
<equipments>
<equipment_id>1</equipment_id>
<equipment_id>8</equipment_id>
</equipments>
</system>
<system name="system 2 gas pv">
<equipments>
<equipment_id>1</equipment_id>
<equipment_id>8</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 2 electricity">
<equipments>
<equipment_id>2</equipment_id>
<equipment_id>8</equipment_id>
</equipments>
</system>
<system name="system 2 electricity pv">
<equipments>
<equipment_id>2</equipment_id>
<equipment_id>8</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 3 and 4 gas">
<equipments>
<equipment_id>3</equipment_id>
<equipment_id>4</equipment_id>
</equipments>
</system>
<system name="system 3 and 4 gas pv">
<equipments>
<equipment_id>3</equipment_id>
<equipment_id>4</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 3 and 4 electricity">
<equipments>
<equipment_id>4</equipment_id>
<equipment_id>4</equipment_id>
</equipments>
</system>
<system name="system 3 and 4 electricity pv">
<equipments>
<equipment_id>4</equipment_id>
<equipment_id>4</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 5">
<equipments>
<equipment_id>8</equipment_id>
</equipments>
</system>
<system name="system 5 pv">
<equipments>
<equipment_id>8</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 6 gas">
<equipments>
<equipment_id>5</equipment_id>
<equipment_id>8</equipment_id>
</equipments>
</system>
<system name="system 6 gas pv">
<equipments>
<equipment_id>5</equipment_id>
<equipment_id>8</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
<system name="system 6 electricity">
<equipments>
<equipment_id>6</equipment_id>
<equipment_id>8</equipment_id>
</equipments>
</system>
<system name="system 6] electricity pv">
<equipments>
<equipment_id>6</equipment_id>
<equipment_id>8</equipment_id>
<equipment_id>10</equipment_id>
</equipments>
</system>
</systems> </systems>