moved data folder to libs and changed:
def __init__(self, handler, city, base_path=Path(Path.cwd().parent / 'libs/data/physics')): in physics_factory.py plus the paths in us_base_physics_parameters.py Something similar should be done for usage_factory.py
This commit is contained in:
parent
4dff9d3ba5
commit
877a64a06e
785
data/physics/us_archetypes.xml
Normal file
785
data/physics/us_archetypes.xml
Normal file
|
@ -0,0 +1,785 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<archetypes reference_library_building_type="us_library" >
|
||||
<archetype id="1" building_type="small office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="13" type="exterior wall" >
|
||||
<window_ratio units="-">0.21</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="22" type="exterior slab" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="5" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">2</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.33</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="22" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.34</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="13" type="exterior wall" >
|
||||
<window_ratio units="-">0.38</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="18" type="interior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.34</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.35</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="22" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0.0019</window_ratio>
|
||||
<window>2</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.96</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.33</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="22" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0.0068</window_ratio>
|
||||
<window>2</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.96</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="13" type="exterior wall" >
|
||||
<window_ratio units="-">0.07</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0.0064</window_ratio>
|
||||
<window>2</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">6.1</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.11</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">5.18</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="13" type="exterior wall" >
|
||||
<window_ratio units="-">0.11</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">6.1</average_storey_height>
|
||||
<number_of_storeys units="-">1</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="3" type="exterior wall" >
|
||||
<window_ratio units="-">0.14</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="5" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.17</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="5" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.11</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="13" type="exterior wall" >
|
||||
<window_ratio units="-">0.3</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="18" type="interior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="13" type="exterior wall" >
|
||||
<window_ratio units="-">0.15</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="18" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">4.27</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.2</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="21" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="24" type="exterior wall" >
|
||||
<window_ratio units="-">0.006</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="20" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="14" type="roof" >
|
||||
<window_ratio units="-">.0032</window_ratio>
|
||||
<window>2</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">8.53</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.15</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="22" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="19" type="exterior wall" >
|
||||
<window_ratio units="-">0.3</window_ratio>
|
||||
<window>4</window>
|
||||
</construction>
|
||||
<construction id="22" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="17" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.15</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="2" type="exterior wall" >
|
||||
<window_ratio units="-">0.21</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="12" type="exterior slab" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="4" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">2</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.33</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="12" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.34</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="2" type="exterior wall" >
|
||||
<window_ratio units="-">0.38</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="1" type="interior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.34</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.35</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="12" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0.0019</window_ratio>
|
||||
<window>1</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.96</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.33</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="12" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0.0068</window_ratio>
|
||||
<window>1</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.96</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="2" type="exterior wall" >
|
||||
<window_ratio units="-">0.07</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0.0064</window_ratio>
|
||||
<window>1</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">6.1</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.11</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">5.18</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="2" type="exterior wall" >
|
||||
<window_ratio units="-">0.11</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">6.1</average_storey_height>
|
||||
<number_of_storeys units="-">1</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="16" type="exterior wall" >
|
||||
<window_ratio units="-">0.14</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="4" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.17</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="4" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.11</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="2" type="exterior wall" >
|
||||
<window_ratio units="-">0.3</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="1" type="interior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="2" type="exterior wall" >
|
||||
<window_ratio units="-">0.15</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="1" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">4.27</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">130</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.2</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="10" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="23" type="exterior wall" >
|
||||
<window_ratio units="-">0.006</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="7" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="11" type="roof" >
|
||||
<window_ratio units="-">.0032</window_ratio>
|
||||
<window>1</window>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">8.53</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.15</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="12" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
<construction id="15" type="exterior wall" >
|
||||
<window_ratio units="-">0.3</window_ratio>
|
||||
<window>3</window>
|
||||
</construction>
|
||||
<construction id="12" type="exterior slab">
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
<construction id="9" type="roof" >
|
||||
<window_ratio units="-">0</window_ratio>
|
||||
<window/>
|
||||
</construction>
|
||||
</constructions>
|
||||
<average_storey_height units="m">3.05</average_storey_height>
|
||||
<number_of_storeys units="-">3</number_of_storeys>
|
||||
<thermal_capacity units="kJ/K m2">90</thermal_capacity>
|
||||
<extra_loses_due_to_thermal_bridges units="W/K m2">0.05</extra_loses_due_to_thermal_bridges>
|
||||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
</archetype>
|
||||
</archetypes>
|
606
data/physics/us_constructions.xml
Normal file
606
data/physics/us_constructions.xml
Normal file
|
@ -0,0 +1,606 @@
|
|||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<library name="us_library">
|
||||
<windows>
|
||||
<window type="skylight" id="1" name="189.1-2009 Nonres 4B Skylight without Curb">
|
||||
<shgc>0.32</shgc>
|
||||
<frame_ratio units="-">0</frame_ratio>
|
||||
<thickness units="m">0.003</thickness>
|
||||
<solar_transmittance_at_normal_incidence units="-">0.301483</solar_transmittance_at_normal_incidence>
|
||||
<front_side_solar_transmittance_at_normal_incidence units="-">0.648517</front_side_solar_transmittance_at_normal_incidence>
|
||||
<back_side_solar_transmittance_at_normal_incidence units="-">0.648517</back_side_solar_transmittance_at_normal_incidence>
|
||||
<conductivity units="W/m K">0.0133144</conductivity>
|
||||
</window>
|
||||
<window type="skylight" id="2" name="90.1-2004 Nonres 4B Skylight without Curb">
|
||||
<shgc>0.49</shgc>
|
||||
<frame_ratio units="-">0</frame_ratio>
|
||||
<thickness units="m">0.003</thickness>
|
||||
<solar_transmittance_at_normal_incidence units="-">0.481761</solar_transmittance_at_normal_incidence>
|
||||
<front_side_solar_transmittance_at_normal_incidence units="-">0.468239</front_side_solar_transmittance_at_normal_incidence>
|
||||
<back_side_solar_transmittance_at_normal_incidence units="-">0.468239</back_side_solar_transmittance_at_normal_incidence>
|
||||
<conductivity units="W/m K">0.03026</conductivity>
|
||||
</window>
|
||||
<window type="window" id="3" name="189.1-2009 Nonres 4B Window Nonmetal framing">
|
||||
<shgc>0.35</shgc>
|
||||
<frame_ratio units="-">0</frame_ratio>
|
||||
<thickness units="m">0.003</thickness>
|
||||
<solar_transmittance_at_normal_incidence units="-">0.328881</solar_transmittance_at_normal_incidence>
|
||||
<front_side_solar_transmittance_at_normal_incidence units="-">0.621119</front_side_solar_transmittance_at_normal_incidence>
|
||||
<back_side_solar_transmittance_at_normal_incidence units="-">0.621119</back_side_solar_transmittance_at_normal_incidence>
|
||||
<conductivity units="W/m K">0.0071399</conductivity>
|
||||
</window>
|
||||
<window type="window" id="4" name="90.1-2004 Nonres 4B Window Fixed">
|
||||
<shgc>0.36</shgc>
|
||||
<frame_ratio units="-">0</frame_ratio>
|
||||
<thickness units="m">0.003</thickness>
|
||||
<solar_transmittance_at_normal_incidence units="-">0.354957</solar_transmittance_at_normal_incidence>
|
||||
<front_side_solar_transmittance_at_normal_incidence units="-">0.595043</front_side_solar_transmittance_at_normal_incidence>
|
||||
<back_side_solar_transmittance_at_normal_incidence units="-">0.595043</back_side_solar_transmittance_at_normal_incidence>
|
||||
<conductivity units="W/m K">0.0134755</conductivity>
|
||||
</window>
|
||||
</windows>
|
||||
<materials>
|
||||
<material id="1" name="MAT-CC05 8 HW CONCRETE">
|
||||
<conductivity units="W/m K">1.311</conductivity>
|
||||
<density units="kg/m3">2240</density>
|
||||
<specific_heat units="J/kg K">836.8</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="2" name="CP02 CARPET PAD">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.8</visible_absorptance>
|
||||
</material>
|
||||
<material id="3" name="Floor Insulation [4]">
|
||||
<conductivity units="W/m K">0.045</conductivity>
|
||||
<density units="kg/m3">265</density>
|
||||
<specific_heat units="J/kg K">836.8</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="4" name="1IN Stucco">
|
||||
<conductivity units="W/m K">0.6918</conductivity>
|
||||
<density units="kg/m3">1858</density>
|
||||
<specific_heat units="J/kg K">837</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.92</solar_absorptance>
|
||||
<visible_absorptance units="-">0.92</visible_absorptance>
|
||||
</material>
|
||||
<material id="5" name="8IN Concrete HW">
|
||||
<conductivity units="W/m K">1.7296</conductivity>
|
||||
<density units="kg/m3">2243</density>
|
||||
<specific_heat units="J/kg K">837</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.65</solar_absorptance>
|
||||
<visible_absorptance units="-">0.65</visible_absorptance>
|
||||
</material>
|
||||
<material id="6" name="Wall Insulation [37]">
|
||||
<conductivity units="W/m K">0.0432</conductivity>
|
||||
<density units="kg/m3">91</density>
|
||||
<specific_heat units="J/kg K">837</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.5</solar_absorptance>
|
||||
<visible_absorptance units="-">0.5</visible_absorptance>
|
||||
</material>
|
||||
<material id="7" name="1/2IN Gypsum">
|
||||
<conductivity units="W/m K">0.16</conductivity>
|
||||
<density units="kg/m3">784.9</density>
|
||||
<specific_heat units="J/kg K">830</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.92</solar_absorptance>
|
||||
<visible_absorptance units="-">0.92</visible_absorptance>
|
||||
</material>
|
||||
<material id="8" name="Wood Siding">
|
||||
<conductivity units="W/m K">0.11</conductivity>
|
||||
<density units="kg/m3">544.62</density>
|
||||
<specific_heat units="J/kg K">1210</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.78</solar_absorptance>
|
||||
<visible_absorptance units="-">0.78</visible_absorptance>
|
||||
</material>
|
||||
<material id="9" name="Wood Shingles">
|
||||
<conductivity units="W/m K">0.115</conductivity>
|
||||
<density units="kg/m3">513</density>
|
||||
<specific_heat units="J/kg K">1255</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.78</solar_absorptance>
|
||||
<visible_absorptance units="-">0.78</visible_absorptance>
|
||||
</material>
|
||||
<material id="10" name="1IN Wood Decking">
|
||||
<conductivity units="W/m K">0.1211</conductivity>
|
||||
<density units="kg/m3">593</density>
|
||||
<specific_heat units="J/kg K">2510</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.78</solar_absorptance>
|
||||
<visible_absorptance units="-">0.78</visible_absorptance>
|
||||
</material>
|
||||
<material id="11" name="Roof Insulation [23]">
|
||||
<conductivity units="W/m K">0.049</conductivity>
|
||||
<density units="kg/m3">265</density>
|
||||
<specific_heat units="J/kg K">836.8</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="12" name="MAT-SHEATH">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="13" name="MAT-SHEATH">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="14" name="Metal Decking">
|
||||
<conductivity units="W/m K">45.006</conductivity>
|
||||
<density units="kg/m3">7680</density>
|
||||
<specific_heat units="J/kg K">418.4</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.3</visible_absorptance>
|
||||
</material>
|
||||
<material id="15" name="Roof Membrane">
|
||||
<conductivity units="W/m K">0.16</conductivity>
|
||||
<density units="kg/m3">1121.29</density>
|
||||
<specific_heat units="J/kg K">1460</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="16" name="CP02 CARPET PAD">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.8</visible_absorptance>
|
||||
</material>
|
||||
<material id="17" name="MAT-SHEATH">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="18" name="CP02 CARPET PAD">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.8</visible_absorptance>
|
||||
</material>
|
||||
<material id="19" name="MAT-SHEATH">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.36256</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="20" name="CP02 CARPET PAD">
|
||||
<no_mass>true</no_mass>
|
||||
<thermal_resistance units="m2 K/W">0.21648</thermal_resistance>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.8</visible_absorptance>
|
||||
</material>
|
||||
<material id="21" name="Wall Insulation [38]">
|
||||
<conductivity units="W/m K">0.045</conductivity>
|
||||
<density units="kg/m3">265</density>
|
||||
<specific_heat units="J/kg K">836.8</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.7</solar_absorptance>
|
||||
<visible_absorptance units="-">0.7</visible_absorptance>
|
||||
</material>
|
||||
<material id="22" name="metal siding">
|
||||
<conductivity units="W/m K">44.96</conductivity>
|
||||
<density units="kg/m3">7688.86</density>
|
||||
<specific_heat units="J/kg K">410</specific_heat>
|
||||
<thermal_absorptance units="-">0.9</thermal_absorptance>
|
||||
<solar_absorptance units="-">0.2</solar_absorptance>
|
||||
<visible_absorptance units="-">0.2</visible_absorptance>
|
||||
</material>
|
||||
|
||||
</materials>
|
||||
<constructions>
|
||||
<construction type="exterior slab" id="1" name="189.1-2009 Nonres 4B Exposed Floor Mass">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.0795397</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.20321</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>2</material>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="2" name="189.1-2009 Nonres 4B Ext Wall Mass">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>4</material>
|
||||
<thickness units="m">0.0253</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>5</material>
|
||||
<thickness units="m">0.2033</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>6</material>
|
||||
<thickness units="m">0.0680962</thickness>
|
||||
</layer>
|
||||
<layer id="4" name="Layer 4">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="3" name="90.1-2004 Nonres 4B Ext Wall Wood-Framed and Other">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>8</material>
|
||||
<thickness units="m">0.01</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.0746874</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="roof" id="4" name="189.1-2009 Nonres 4B Roof Attic and Other">
|
||||
<outside_solar_absorptance units="-">0.78</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.78</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>9</material>
|
||||
<thickness units="m">0.0178</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>10</material>
|
||||
<thickness units="m">0.0254</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>11</material>
|
||||
<thickness units="m">0.375211</thickness>
|
||||
</layer>
|
||||
<layer id="4" name="Layer 4">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="roof" id="5" name="90.1-2004 Nonres 4B Roof Attic and Other">
|
||||
<outside_solar_absorptance units="-">0.78</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.78</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>9</material>
|
||||
<thickness units="m">0.0178</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>10</material>
|
||||
<thickness units="m">0.0254</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>11</material>
|
||||
<thickness units="m">0.221604</thickness>
|
||||
</layer>
|
||||
<layer id="4" name="Layer 4">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="6" name="189.1-2009 Nonres 4B Ext Wall Steel-Framed">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>12</material>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.118387</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="7" name="189.1-2009 Nonres 4B Ext Slab Unheated - 8in Slab without Carpet">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.20321</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="8" name="90.1-2004 Nonres 4B Ext Wall Steel-Framed">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>13</material>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.0373223</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="roof" id="9" name="189.1-2009 Nonres 4B Roof IEAD">
|
||||
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.7</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>15</material>
|
||||
<thickness units="m">0.0095</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>11</material>
|
||||
<thickness units="m">0.210538</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>14</material>
|
||||
<thickness units="m">0.001524</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="10" name="189.1-2009 Nonres 4B Ext Slab Unheated - 4in Slab without Carpet">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.1016</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="roof" id="11" name="189.1-2009 Nonres 4B Roof Metal Building">
|
||||
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.3</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>14</material>
|
||||
<thickness units="m">0.001524</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>11</material>
|
||||
<thickness units="m">0.23578</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="12" name="189.1-2009 Nonres 4B Ext Slab Unheated - 4in Slab with Carpet">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.1016</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>16</material>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="13" name="90.1-2004 Nonres 4B Ext Wall Mass">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>4</material>
|
||||
<thickness units="m">0.0253</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>5</material>
|
||||
<thickness units="m">0.2033</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>6</material>
|
||||
<thickness units="m">0.0338606</thickness>
|
||||
</layer>
|
||||
<layer id="4" name="Layer 4">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="roof" id="14" name="90.1-2004 Nonres 4B Roof Metal Building">
|
||||
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.3</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>14</material>
|
||||
<thickness units="m">0.001524</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>11</material>
|
||||
<thickness units="m">0.123533</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="15" name="189.1-2009 Res 4B Ext Wall Steel-Framed">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>17</material>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.118387</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="16" name="189.1-2009 Nonres 4B Ext Wall Wood-Framed and Other">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>8</material>
|
||||
<thickness units="m">0.01</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.110422</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="roof" id="17" name="90.1-2004 Nonres 4B Roof IEAD">
|
||||
<outside_solar_absorptance units="-">0.7</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.7</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>15</material>
|
||||
<thickness units="m">0.0095</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>11</material>
|
||||
<thickness units="m">0.124958</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>14</material>
|
||||
<thickness units="m">0.001524</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="18" name="90.1-2004 Nonres 4B Exposed Floor Mass">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.0463846</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.20321</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>18</material>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="19" name="90.1-2004 Res 4B Ext Wall Steel-Framed">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>19</material>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>3</material>
|
||||
<thickness units="m">0.0971136</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="20" name="90.1-2004 Nonres 4B Ext Slab Unheated - 8in Slab without Carpet">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.20321</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="21" name="90.1-2004 Nonres 4B Ext Slab Unheated - 4in Slab without Carpet">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.1016</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior slab" id="22" name="90.1-2004 Nonres 4B Ext Slab Unheated - 4in Slab with Carpet">
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>1</material>
|
||||
<thickness units="m">0.1016</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>20</material>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="23" name="189.1-2009 Nonres 4B Ext Wall Metal Building">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>22</material>
|
||||
<thickness units="m">0.0015</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>21</material>
|
||||
<thickness units="m">0.139618</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
<construction type="exterior wall" id="24" name="90.1-2004 Nonres 4B Ext Wall Metal Building">
|
||||
<outside_solar_absorptance units="-">0.92</outside_solar_absorptance>
|
||||
<outside_thermal_absorptance units="-">0.9</outside_thermal_absorptance>
|
||||
<outside_visible_absorptance units="-">0.92</outside_visible_absorptance>
|
||||
<layers>
|
||||
<layer id="1" name="Layer 1">
|
||||
<material>22</material>
|
||||
<thickness units="m">0.0015</thickness>
|
||||
</layer>
|
||||
<layer id="2" name="Layer 2">
|
||||
<material>21</material>
|
||||
<thickness units="m">0.0598725</thickness>
|
||||
</layer>
|
||||
<layer id="3" name="Layer 3">
|
||||
<material>7</material>
|
||||
<thickness units="m">0.01271</thickness>
|
||||
</layer>
|
||||
</layers>
|
||||
</construction>
|
||||
</constructions>
|
||||
</library>
|
2027
data/usage/de_library.xml
Normal file
2027
data/usage/de_library.xml
Normal file
File diff suppressed because it is too large
Load Diff
Loading…
Reference in New Issue
Block a user