The city energy system importer for the north america is modified and tested.
This commit is contained in:
parent
978cc9d1ea
commit
9c1e05939a
|
@ -70,12 +70,14 @@ class MontrealCustomCatalog(Catalog):
|
|||
storage_systems = [storage_system]
|
||||
if model_name == 'PV system':
|
||||
generation_system = PvGenerationSystem(equipment_id,
|
||||
name=None,
|
||||
model_name=model_name,
|
||||
electricity_efficiency=electricity_efficiency,
|
||||
energy_storage_systems=storage_systems
|
||||
)
|
||||
else:
|
||||
generation_system = NonPvGenerationSystem(equipment_id,
|
||||
name=None,
|
||||
model_name=model_name,
|
||||
system_type=equipment_type,
|
||||
fuel_type=fuel_type,
|
||||
|
|
|
@ -28,7 +28,7 @@ class NorthAmericaEnergySystemCatalog(Catalog):
|
|||
def __init__(self, path):
|
||||
path = str(path / 'north_america_systems.xml')
|
||||
with open(path, 'r', encoding='utf-8') as xml:
|
||||
self._archetypes = xmltodict.parse(xml.read(), force_list=['photovoltaicModules', 'templateStorages'])
|
||||
self._archetypes = xmltodict.parse(xml.read(), force_list=['photovoltaicModules', 'templateStorages', 'demand'])
|
||||
|
||||
self._storage_components = self._load_storage_components()
|
||||
self._generation_components = self._load_generation_components()
|
||||
|
@ -47,7 +47,7 @@ class NorthAmericaEnergySystemCatalog(Catalog):
|
|||
for boiler in boilers:
|
||||
boiler_id = boiler['@generation_id']
|
||||
name = boiler['@name']
|
||||
system_type = 'Boiler'
|
||||
system_type = 'boiler'
|
||||
boiler_model_name = boiler['@modelName']
|
||||
boiler_manufacturer = boiler['@manufacturer']
|
||||
boiler_fuel_type = boiler['@fuel']
|
||||
|
@ -69,7 +69,7 @@ class NorthAmericaEnergySystemCatalog(Catalog):
|
|||
for heat_pump in heat_pumps:
|
||||
heat_pump_id = heat_pump['@generation_id']
|
||||
name = heat_pump['@name']
|
||||
system_type = 'Heat Pump'
|
||||
system_type = 'heat pump'
|
||||
heat_pump_model_name = heat_pump['@modelName']
|
||||
heat_pump_manufacturer = heat_pump['@manufacturer']
|
||||
heat_pump_fuel_type = heat_pump['@fuel']
|
||||
|
|
|
@ -20,6 +20,7 @@ class GenerationSystem(ABC):
|
|||
"""
|
||||
def __init__(self):
|
||||
self._system_type = None
|
||||
self._name = None
|
||||
self._model_name = None
|
||||
self._manufacturer = None
|
||||
self._fuel_type = None
|
||||
|
@ -42,6 +43,22 @@ class GenerationSystem(ABC):
|
|||
"""
|
||||
self._system_type = value
|
||||
|
||||
@property
|
||||
def name(self):
|
||||
"""
|
||||
Get name
|
||||
:return: string
|
||||
"""
|
||||
return self._name
|
||||
|
||||
@name.setter
|
||||
def name(self, value):
|
||||
"""
|
||||
Set name
|
||||
:param value: string
|
||||
"""
|
||||
self._name = value
|
||||
|
||||
@property
|
||||
def model_name(self):
|
||||
"""
|
||||
|
|
|
@ -42,9 +42,6 @@ class NonPvGenerationSystem(GenerationSystem):
|
|||
self._cooling_output_curve = None
|
||||
self._cooling_fuel_consumption_curve = None
|
||||
self._cooling_efficiency_curve = None
|
||||
self._heat_power = None
|
||||
self._cooling_power = None
|
||||
self._electricity_power = None
|
||||
|
||||
@property
|
||||
def nominal_heat_output(self):
|
||||
|
@ -430,51 +427,4 @@ class NonPvGenerationSystem(GenerationSystem):
|
|||
"""
|
||||
self._cooling_efficiency_curve = value
|
||||
|
||||
@property
|
||||
def heat_power(self):
|
||||
"""
|
||||
Get heat_power in W
|
||||
:return: float
|
||||
"""
|
||||
return self._heat_power
|
||||
|
||||
@heat_power.setter
|
||||
def heat_power(self, value):
|
||||
"""
|
||||
Set heat_power in W
|
||||
:param value: float
|
||||
"""
|
||||
self._heat_power = value
|
||||
|
||||
@property
|
||||
def cooling_power(self):
|
||||
"""
|
||||
Get cooling_power in W
|
||||
:return: float
|
||||
"""
|
||||
return self._cooling_power
|
||||
|
||||
@cooling_power.setter
|
||||
def cooling_power(self, value):
|
||||
"""
|
||||
Set cooling_power in W
|
||||
:param value: float
|
||||
"""
|
||||
self._cooling_power = value
|
||||
|
||||
@property
|
||||
def electricity_power(self):
|
||||
"""
|
||||
Get electricity_power in W
|
||||
:return: float
|
||||
"""
|
||||
return self._electricity_power
|
||||
|
||||
@electricity_power.setter
|
||||
def electricity_power(self, value):
|
||||
"""
|
||||
Set electricity_power in W
|
||||
:param value: float
|
||||
"""
|
||||
self._electricity_power = value
|
||||
|
||||
|
|
|
@ -6,25 +6,23 @@ Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
|
|||
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
|
||||
"""
|
||||
|
||||
import copy
|
||||
import logging
|
||||
|
||||
from pandas import DataFrame
|
||||
import copy
|
||||
|
||||
from hub.catalog_factories.energy_systems_catalog_factory import EnergySystemsCatalogFactory
|
||||
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
||||
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
|
||||
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
||||
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
||||
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||
from hub.city_model_structure.energy_systems.energy_system import EnergySystem
|
||||
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
|
||||
from hub.city_model_structure.energy_systems.non_pv_generation_system import NonPvGenerationSystem
|
||||
from hub.city_model_structure.energy_systems.pv_generation_system import PvGenerationSystem
|
||||
from hub.city_model_structure.energy_systems.electrical_storage_system import ElectricalStorageSystem
|
||||
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
|
||||
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
|
||||
from hub.helpers.dictionaries import Dictionaries
|
||||
|
||||
|
||||
class NorthAmericaCustomEnergySystemParameters:
|
||||
"""
|
||||
NorthAmericaCustomEnergySystemParameters class
|
||||
MontrealCustomEnergySystemParameters class
|
||||
"""
|
||||
|
||||
def __init__(self, city):
|
||||
|
@ -36,11 +34,7 @@ class NorthAmericaCustomEnergySystemParameters:
|
|||
:return:
|
||||
"""
|
||||
city = self._city
|
||||
north_america_custom_catalog = EnergySystemsCatalogFactory('north_america').catalog
|
||||
if city.energy_systems_connection_table is None:
|
||||
_energy_systems_connection_table = DataFrame(columns=['Energy System Type', 'Building'])
|
||||
else:
|
||||
_energy_systems_connection_table = city.energy_systems_connection_table
|
||||
montreal_custom_catalog = EnergySystemsCatalogFactory('north_america').catalog
|
||||
if city.generic_energy_systems is None:
|
||||
_generic_energy_systems = {}
|
||||
else:
|
||||
|
@ -48,21 +42,18 @@ class NorthAmericaCustomEnergySystemParameters:
|
|||
for building in city.buildings:
|
||||
archetype_name = building.energy_systems_archetype_name
|
||||
try:
|
||||
archetype = self._search_archetypes(north_america_custom_catalog, archetype_name)
|
||||
archetype = self._search_archetypes(montreal_custom_catalog, archetype_name)
|
||||
except KeyError:
|
||||
logging.error('Building %s has unknown energy system archetype for system name %s', building.name,
|
||||
archetype_name)
|
||||
continue
|
||||
_energy_systems_connection_table, _generic_energy_systems = self._create_generic_systems(
|
||||
archetype,
|
||||
building,
|
||||
_energy_systems_connection_table,
|
||||
_generic_energy_systems
|
||||
)
|
||||
city.energy_systems_connection_table = _energy_systems_connection_table
|
||||
|
||||
if archetype.name not in _generic_energy_systems:
|
||||
_generic_energy_systems = self._create_generic_systems_list(archetype, _generic_energy_systems)
|
||||
|
||||
city.generic_energy_systems = _generic_energy_systems
|
||||
|
||||
self._associate_energy_systems(city)
|
||||
self._assign_energy_systems_to_buildings(city)
|
||||
|
||||
@staticmethod
|
||||
def _search_archetypes(catalog, name):
|
||||
|
@ -72,98 +63,93 @@ class NorthAmericaCustomEnergySystemParameters:
|
|||
return building_archetype
|
||||
raise KeyError('archetype not found')
|
||||
|
||||
@staticmethod
|
||||
def _create_generic_systems(archetype, building,
|
||||
_energy_systems_connection_table, _generic_energy_systems):
|
||||
def _create_generic_systems_list(self, archetype, _generic_energy_systems):
|
||||
building_systems = []
|
||||
data = [archetype.name, building.name]
|
||||
_energy_systems_connection_table.loc[len(_energy_systems_connection_table)] = data
|
||||
for system in archetype.systems:
|
||||
for archetype_system in archetype.systems:
|
||||
energy_system = EnergySystem()
|
||||
_hub_demand_types = []
|
||||
demand_types = system.demand_types
|
||||
if isinstance(demand_types, str):
|
||||
demand_types = [demand_types]
|
||||
for demand_type in demand_types:
|
||||
_hub_demand_types.append(Dictionaries().north_america_demand_type_to_hub_energy_demand_type[demand_type])
|
||||
energy_system.name = system.name
|
||||
for demand_type in archetype_system.demand_types:
|
||||
_hub_demand_types.append(Dictionaries().montreal_demand_type_to_hub_energy_demand_type[demand_type])
|
||||
energy_system.name = archetype_system.name
|
||||
energy_system.demand_types = _hub_demand_types
|
||||
archetype_generation_equipments = system.generation_systems
|
||||
_generation_systems = []
|
||||
for archetype_generation_equipment in archetype_generation_equipments:
|
||||
_generation_system = GenerationSystem()
|
||||
_type = archetype_generation_equipment.name
|
||||
_generation_system.type = Dictionaries().north_america_system_to_hub_energy_generation_system[_type]
|
||||
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_equipment.fuel_type]
|
||||
_generation_system.fuel_type = _fuel_type
|
||||
_generation_system.source_types = archetype_generation_equipment.source_medium
|
||||
_generation_system.heat_efficiency = archetype_generation_equipment.heat_efficiency
|
||||
_generation_system.cooling_efficiency = archetype_generation_equipment.cooling_efficiency
|
||||
_generation_system.electricity_efficiency = archetype_generation_equipment.electricity_efficiency
|
||||
_generation_system.source_temperature = archetype_generation_equipment.source_temperature
|
||||
_generation_system.source_mass_flow = archetype_generation_equipment.source_mass_flow
|
||||
_generation_system.storage = None
|
||||
_generation_system.auxiliary_equipment = None
|
||||
_generation_system.supply_medium = archetype_generation_equipment.supply_medium
|
||||
_generation_system.maximum_heat_supply_temperature = archetype_generation_equipment.maximum_heat_supply_temperature
|
||||
_generation_system.minimum_heat_supply_temperature = archetype_generation_equipment.minimum_heat_supply_temperature
|
||||
_generation_system.maximum_cooling_supply_temperature = archetype_generation_equipment.maximum_cooling_supply_temperature
|
||||
_generation_system.minimum_cooling_supply_temperature = archetype_generation_equipment.minimum_cooling_supply_temperature
|
||||
_generation_system.heat_output_curve = archetype_generation_equipment.heat_output_curve
|
||||
_generation_system.heat_fuel_consumption_curve = archetype_generation_equipment.heat_fuel_consumption_curve
|
||||
_generation_system.heat_efficiency_curve = archetype_generation_equipment.heat_efficiency_curve
|
||||
_generation_system.cooling_output_curve = archetype_generation_equipment.cooling_output_curve
|
||||
_generation_system.cooling_fuel_consumption_curve = archetype_generation_equipment.cooling_fuel_consumption_curve
|
||||
_generation_system.cooling_efficiency_curve = archetype_generation_equipment.cooling_efficiency_curve
|
||||
_generation_systems.append(_generation_system)
|
||||
|
||||
energy_system.generation_systems = _generation_systems
|
||||
|
||||
_thermal_storage_system = ThermalStorageSystem()
|
||||
archetype_storage_equipments = system.energy_storage_systems
|
||||
if archetype_storage_equipments is not None:
|
||||
for archetype_storage_equipment in archetype_storage_equipments:
|
||||
_thermal_storage_system.maximum_operating_temperature = archetype_storage_equipment.maximum_operating_temperature
|
||||
_thermal_storage_system.height = archetype_storage_equipment.height
|
||||
_thermal_storage_system.layers = archetype_storage_equipment.layers
|
||||
energy_system.energy_storage_systems = _thermal_storage_system
|
||||
|
||||
energy_system.configuration_schema = archetype_system.configuration_schema
|
||||
energy_system.generation_systems = self._create_generation_systems(archetype_system)
|
||||
if energy_system.distribution_systems is not None:
|
||||
energy_system.distribution_systems = self._create_distribution_systems(archetype_system)
|
||||
building_systems.append(energy_system)
|
||||
if archetype.name not in _generic_energy_systems:
|
||||
|
||||
_generic_energy_systems[archetype.name] = building_systems
|
||||
|
||||
return _energy_systems_connection_table, _generic_energy_systems
|
||||
return _generic_energy_systems
|
||||
|
||||
@staticmethod
|
||||
def _associate_energy_systems(city):
|
||||
energy_systems_connection = city.energy_systems_connection_table
|
||||
def _create_generation_systems(archetype_system):
|
||||
_generation_systems = []
|
||||
for archetype_generation_system in archetype_system.generation_systems:
|
||||
if archetype_generation_system.system_type == 'PV system':
|
||||
_generation_system = PvGenerationSystem()
|
||||
_type = 'PV system'
|
||||
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
||||
_fuel_type = Dictionaries().montreal_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
||||
_generation_system.fuel_type = _fuel_type
|
||||
_generation_system.electricity_efficiency = archetype_generation_system.electricity_efficiency
|
||||
_generic_storage_system = None
|
||||
if archetype_generation_system.energy_storage_systems is not None:
|
||||
_generic_storage_system = ElectricalStorageSystem()
|
||||
_generic_storage_system.type_energy_stored = 'electrical'
|
||||
_generation_system.energy_storage_systems = [_generic_storage_system]
|
||||
else:
|
||||
_generation_system = NonPvGenerationSystem()
|
||||
_type = archetype_generation_system.system_type
|
||||
_generation_system.system_type = Dictionaries().montreal_generation_system_to_hub_energy_generation_system[_type]
|
||||
_fuel_type = Dictionaries().north_america_custom_fuel_to_hub_fuel[archetype_generation_system.fuel_type]
|
||||
_generation_system.fuel_type = _fuel_type
|
||||
_generation_system.source_types = archetype_generation_system.source_medium
|
||||
_generation_system.heat_efficiency = archetype_generation_system.heat_efficiency
|
||||
_generation_system.cooling_efficiency = archetype_generation_system.cooling_efficiency
|
||||
_generation_system.electricity_efficiency = archetype_generation_system.electricity_efficiency
|
||||
_generic_storage_system = None
|
||||
if archetype_generation_system.energy_storage_systems is not None:
|
||||
_storage_systems = []
|
||||
for storage_system in archetype_generation_system.energy_storage_systems:
|
||||
if storage_system.type_energy_stored == 'electrical':
|
||||
_generic_storage_system = ElectricalStorageSystem()
|
||||
_generic_storage_system.type_energy_stored = 'electrical'
|
||||
else:
|
||||
_generic_storage_system = ThermalStorageSystem()
|
||||
_generic_storage_system.type_energy_stored = 'thermal'
|
||||
_storage_systems.append(_generic_storage_system)
|
||||
_generation_system.energy_storage_systems = [_storage_systems]
|
||||
_generation_systems.append(_generation_system)
|
||||
return _generation_systems
|
||||
|
||||
@staticmethod
|
||||
def _create_distribution_systems(archetype_system):
|
||||
_distribution_systems = []
|
||||
for archetype_distribution_system in archetype_system.distribution_systems:
|
||||
_distribution_system = DistributionSystem()
|
||||
_distribution_system.type = archetype_distribution_system.type
|
||||
_distribution_system.distribution_consumption_fix_flow = \
|
||||
archetype_distribution_system.distribution_consumption_fix_flow
|
||||
_distribution_system.distribution_consumption_variable_flow = \
|
||||
archetype_distribution_system.distribution_consumption_variable_flow
|
||||
_distribution_system.heat_losses = archetype_distribution_system.heat_losses
|
||||
_emission_system = None
|
||||
if archetype_distribution_system.emission_systems is not None:
|
||||
_emission_system = EmissionSystem()
|
||||
_distribution_system.emission_systems = [_emission_system]
|
||||
_distribution_systems.append(_distribution_system)
|
||||
return _distribution_systems
|
||||
|
||||
@staticmethod
|
||||
def _assign_energy_systems_to_buildings(city):
|
||||
for building in city.buildings:
|
||||
_building_energy_systems = []
|
||||
energy_systems = energy_systems_connection['Energy System Type'][
|
||||
energy_systems_connection['Building'] == building.name]
|
||||
print(energy_systems)
|
||||
for energy_system in energy_systems:
|
||||
if str(energy_system) == 'nan':
|
||||
energy_systems_cluster_name = building.energy_systems_archetype_name
|
||||
if str(energy_systems_cluster_name) == 'nan':
|
||||
break
|
||||
_generic_building_energy_systems = city.generic_energy_systems[energy_system]
|
||||
_generic_building_energy_systems = city.generic_energy_systems[energy_systems_cluster_name]
|
||||
for _generic_building_energy_system in _generic_building_energy_systems:
|
||||
_building_energy_equipment = EnergySystem()
|
||||
_building_energy_equipment.name = _generic_building_energy_system.name
|
||||
_building_energy_equipment.demand_types = _generic_building_energy_system.demand_types
|
||||
_generation_systems = []
|
||||
_generic_building_generation_systems = _generic_building_energy_system.generation_systems
|
||||
for _generic_building_generation_system in _generic_building_generation_systems:
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = \
|
||||
copy.deepcopy(_generic_building_generation_system)
|
||||
_generation_systems.append(_building_generation_system)
|
||||
_building_energy_equipment.generation_systems = _generation_systems
|
||||
_building_storage_system = ThermalStorageSystem()
|
||||
_building_storage_system.generic_storage_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_systems)
|
||||
_building_energy_systems.append(copy.deepcopy(_generic_building_energy_system))
|
||||
|
||||
|
||||
_building_energy_equipment.energy_storage_systems = _building_storage_system
|
||||
|
||||
_building_energy_systems.append(_building_energy_equipment)
|
||||
building.energy_systems = _building_energy_systems
|
||||
|
|
|
@ -104,7 +104,6 @@ class TestSystemsFactory(TestCase):
|
|||
building.energy_systems_archetype_name = 'PV+ASHP+GasBoiler+TES'
|
||||
|
||||
EnergySystemsFactory('north_america', self._city).enrich()
|
||||
self.assertEqual(17, len(self._city.energy_systems_connection_table))
|
||||
self.assertEqual(1, len(self._city.generic_energy_systems))
|
||||
|
||||
def test_north_america_custom_system_results(self):
|
||||
|
@ -128,46 +127,18 @@ class TestSystemsFactory(TestCase):
|
|||
building.energy_systems_archetype_name = 'PV+ASHP+GasBoiler+TES'
|
||||
EnergySystemsFactory('north_america', self._city).enrich()
|
||||
# Need to assign energy systems to buildings:
|
||||
energy_systems_connection = self._city.energy_systems_connection_table
|
||||
for building in self._city.buildings:
|
||||
_building_energy_systems = []
|
||||
energy_systems = energy_systems_connection['Energy System Type'][
|
||||
energy_systems_connection['Building'] == building.name]
|
||||
for energy_system in energy_systems:
|
||||
_generic_building_energy_systems = self._city.generic_energy_systems[energy_system]
|
||||
for _generic_building_energy_system in _generic_building_energy_systems:
|
||||
_building_energy_equipment = EnergySystem()
|
||||
_building_energy_equipment.demand_types = _generic_building_energy_system.demand_types
|
||||
|
||||
_building_distribution_system = DistributionSystem()
|
||||
_building_distribution_system.generic_distribution_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.distribution_systems)
|
||||
)
|
||||
_building_emission_system = EmissionSystem()
|
||||
_building_emission_system.generic_emission_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.emission_systems)
|
||||
)
|
||||
_building_generation_system = GenerationSystem()
|
||||
_building_generation_system.generic_generation_system = (
|
||||
copy.deepcopy(_generic_building_energy_system.generation_systems)
|
||||
)
|
||||
_building_storage_system = ThermalStorageSystem()
|
||||
_building_storage_system.generic_storage_system = \
|
||||
copy.deepcopy(_generic_building_energy_system.energy_storage_systems)
|
||||
|
||||
if cte.HEATING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
||||
if cte.COOLING in _building_energy_equipment.demand_types:
|
||||
_building_generation_system.cooling_power = building.cooling_peak_load[cte.YEAR][0]
|
||||
_building_energy_equipment.generation_systems = _building_generation_system
|
||||
_building_energy_equipment.distribution_systems = _building_distribution_system
|
||||
_building_energy_equipment.emission_systems = _building_emission_system
|
||||
|
||||
_building_energy_systems.append(_building_energy_equipment)
|
||||
building.energy_systems = _building_energy_systems
|
||||
for energy_system in building.energy_systems:
|
||||
if cte.HEATING in energy_system.demand_types:
|
||||
_generation_system = cast(NonPvGenerationSystem, energy_system.generation_systems[0])
|
||||
_generation_system.heat_power = building.heating_peak_load[cte.YEAR][0]
|
||||
if cte.COOLING in energy_system.demand_types:
|
||||
_generation_system = cast(NonPvGenerationSystem, energy_system.generation_systems[0])
|
||||
_generation_system.cooling_power = building.cooling_peak_load[cte.YEAR][0]
|
||||
|
||||
for building in self._city.buildings:
|
||||
self.assertLess(0, building.heating_consumption[cte.YEAR][0])
|
||||
self.assertLess(0, building.cooling_consumption[cte.YEAR][0])
|
||||
self.assertEqual(0, building.cooling_consumption[cte.YEAR][0])
|
||||
self.assertLess(0, building.domestic_hot_water_consumption[cte.YEAR][0])
|
||||
self.assertLess(0, building.onsite_electrical_production[cte.YEAR][0])
|
Loading…
Reference in New Issue
Block a user