Commit Graph

231 Commits

Author SHA1 Message Date
a454b8f900 Title: merging changes from hub/final_energy_system_model branch in here 2024-02-07 20:33:46 -05:00
ebaec9bb7c Title: Finalizing the energy system data model and system factory
A new XML file named montreal_future_systems.xml is created where the elements of the file are the same as attributes of various classes. Therefore, the catalogue importer and energy system importer should have been updated accordingly. The catalog importer is organized in a general method so whenever someone wants to create a new catalogue they can use the created code as the blueprint.
2024-02-07 18:54:09 -05:00
3e193f04a6 The dual_supply_capability is added to the city model structure 2024-02-01 15:41:05 -05:00
11e7cf8558 a script named energy_system_sizing.py is created in the importers to size the energy system components. This is a very simple sizing process where we only size the heat pump and boiler for 60 and 40 percent of the maximum demand
The class SystemSimulation in system_simulation.py is created to contain all the simulation models of different archetypes.
main.py is modified to randomly assign base case systems to city and print the heating consumption, and then assign a new system to all buildings and calculate the heating consumption again
2024-01-17 13:10:39 -05:00
ec1c7464f3 a script named energy_system_sizing.py is created in the importers to size the energy system components 2024-01-02 18:30:39 -05:00
c362bdb8b1 small modifications were made to the energy system importer 2023-12-28 20:24:13 -05:00
6e1914963d The error in montreal_custom_energy_system_parameters.py is fixed
Random assignation of systems to city buildings is done
2023-12-28 13:48:22 -05:00
19dcb988f9 The heating and cooling demand units are changed from J to W 2023-12-20 15:53:28 -05:00
57c7a76529 The ep results importer for multiple buildings is completed 2023-12-06 13:53:31 -05:00
020190829f The energy plus result importer for multiple buildings is created and tested. Currently, buildings are enriched with hourly values but monthly and yearly values are not working. 2023-12-05 19:38:11 -05:00
e3f1d52a21 Add .gitignore to exclude Python bytecode files 2023-12-05 12:47:44 -05:00
9c1e05939a The city energy system importer for the north america is modified and tested. 2023-10-17 17:25:13 -04:00
3f649fd020 finished central data model new structure for energy systems, importer and test 2023-10-13 13:31:46 -04:00
d94bce4174 half made changes in central data model for systems 2023-10-13 08:23:40 -04:00
a331dce966 fixed error in logic in _create_generic_systems 2023-10-06 04:14:52 -04:00
ef89da8552 created a loop for generation systems in _associate_energy_systems 2023-10-05 16:18:08 -04:00
9654bee978 modified the names and changed all singulars to plurals 2023-10-05 14:45:33 -04:00
dae117fb44 Merge remote-tracking branch 'origin/energy_plus_result_factory' into energy_plus_result_factory 2023-10-05 14:20:24 -04:00
91fa9d5ca1 modified the names and changed all singulars to plurals 2023-10-05 14:20:02 -04:00
6f40a15609 Merge remote-tracking branch 'origin/energy_system_central_data_model' into energy_system_central_data_model 2023-10-05 13:22:32 -04:00
ca48d6448b changed all the singular names to plural and turned distribution and emission systems into lists 2023-10-05 13:18:57 -04:00
f2bfc297b3 Basic style correction and missing docstrings 2023-10-05 11:30:20 +02:00
d5c443a57b Merge remote-tracking branch 'origin/main' into energy_system_central_data_model 2023-10-05 11:02:13 +02:00
568317ebf1 Merge pull request 'fixing_working_hours_problem' (#47) from fixing_working_hours_problem into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/47
2023-10-05 04:40:58 -04:00
f0ad1462d0 finished the first part of the test. 2023-10-03 17:50:17 -04:00
23a8fbe86d continued working on the importer 2023-10-03 13:07:20 -04:00
087384475f changing from generation system to generation systemS in system importer north america 2023-10-03 09:40:32 -04:00
b914c9e7bf made final changes to north_america_custom_energy_system_parameters.py 2023-10-02 12:39:30 -04:00
cf783d8998 add max height to the city in geojson when the high field is given 2023-09-29 07:54:46 +02:00
eaa3064a3f continued working on energy system importer 2023-09-28 19:19:32 -04:00
8dbbfb9460 finished creating generic generation system in the _create_generic_systems method in north_america_custom_energy_system_parameters.py 2023-09-27 17:48:23 -04:00
3809cf2885 continued the work on importer 2023-09-27 13:00:04 -04:00
8b66e20e9a some refactoring 2023-09-27 05:35:28 -04:00
6d34e41e90 Started working on north america energy system importer. 2023-09-26 18:54:58 -04:00
a43c971bbb modified working hours to give hours a month, not only total 2023-09-25 05:19:02 -04:00
73dffdc367 Merge branch 'systems_catalog_improvement' into energy_plus_result_factory
# Conflicts:
#	.gitignore
2023-09-14 12:34:50 -04:00
cde3bfb4ae tried to get monthly values from the method in helpers/monthly values. 2023-09-08 11:50:20 -04:00
8f8a6dbf71 small changes in importer 2023-09-08 05:05:58 -04:00
1392c05489 results_factory.py is modified
The enrich method is added to energy_plus_workflow.py
The Levis_out.csv is added to test_data
2023-09-07 18:16:07 -04:00
a0d2f7e5bc chnages were made to energy_plus_workflow.py 2023-09-06 14:55:14 -04:00
9624be2cf9 solved bugs introduced with changes in thermal_zone_from_internal_zones new structure 2023-09-01 12:53:01 -04:00
8763523d3b added S to some lists, updated montreal_custom_catalog.py to new catalog classes and removed __future__ from those classes that didn't need it 2023-08-29 12:50:49 -04:00
6551eb6402 partial correction for persistence
IMPORTANT: This version neec top be checked for meb import as seems that the cooling and heating demand aren't imported properly.
2023-08-29 05:55:40 +02:00
ff1bb80a6c Merge remote-tracking branch 'origin/main' 2023-08-22 10:26:29 -04:00
491b976fd9 Correct error in meb (temporary workaround) 2023-08-22 10:25:40 -04:00
e20a700deb emission_system.py is rolled back to original
performance_curves.py is imported in generation_system.py
The order of arguments in pv_generation_system.py is fixed
Modulation range is replaced with maximum and minimum heat output in generation_system.py
maximum,minimum, and nominal cooling output are also added to generation_system.py
2023-08-17 18:48:48 -04:00
32a40f17a6 fixing pv problem 2023-08-16 16:28:20 -04:00
d564218531 Merge remote-tracking branch 'origin/main'
# Conflicts:
#	hub/helpers/data/montreal_function_to_hub_function.py
#	hub/imports/construction/helpers/construction_helper.py
2023-08-10 11:03:09 -04:00
ebb712ebaf Add missing values to reference city to climate zone and to montreal functions 2023-08-10 11:01:37 -04:00
deb04cbe2d Add retrieve result test and correct lock in sqlalchemy 2023-08-09 13:52:55 -04:00