Program Version,EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2024.01.18 14:11, ** Warning ** GetHTSurfaceData: Surfaces with interface to Ground found but no "Ground Temperatures" were input. ** ~~~ ** Found first in surface=6ACF7617-7D20-4059-916F-A322696BF7D6 ** ~~~ ** Defaults, constant throughout the year of (18.0) will be used. ** Warning ** GetInternalHeatGains: People="175785_OCCUPANCY", Activity Level Schedule Name values ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. ** ~~~ ** Odd comfort values may result; Schedule="ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING". ** ~~~ ** Entered min/max range=[0.0,] W/person.146.5 ** Warning ** GetInternalHeatGains: People="176293_OCCUPANCY", Activity Level Schedule Name values ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. ** ~~~ ** Odd comfort values may result; Schedule="ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING". ** ~~~ ** Entered min/max range=[0.0,] W/person.146.5 ** Warning ** GetInternalHeatGains: People="182393_OCCUPANCY", Activity Level Schedule Name values ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. ** ~~~ ** Odd comfort values may result; Schedule="ACTIVITY LEVEL SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING". ** ~~~ ** Entered min/max range=[0.0,] W/person.146.5 ** Warning ** DetermineShadowingCombinations: There are 1 surfaces which are receiving surfaces and are non-convex. ** ~~~ ** ...Shadowing values may be inaccurate. Check .shd report file for more surface shading details ** ~~~ ** ...Add Output:Diagnostics,DisplayExtraWarnings; to see individual warnings for each surface. ************* Testing Individual Branch Integrity ************* All Branches passed integrity testing ************* Testing Individual Supply Air Path Integrity ************* All Supply Air Paths passed integrity testing ************* Testing Individual Return Air Path Integrity ************* All Return Air Paths passed integrity testing ************* No node connection errors were found. ************* Beginning Simulation ** Severe ** Output:Table:SummaryReports Field[6]="STANDARD62.1SUMMARY", invalid report name -- will not be reported. ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'EndUseEnergyConsumptionOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL1' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'EXTERIOREQUIPMENT:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COOLING:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'HEATING:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'WATERSYSTEMS:OTHERFUEL2' ** Warning ** In Output:Table:Monthly 'PeakEnergyEndUseOtherFuelsMonthly' invalid Variable or Meter Name 'COGENERATION:OTHERFUEL2' ** Warning ** Processing Monthly Tabular Reports: Variable names not valid for this simulation ** ~~~ ** ...use Output:Diagnostics,DisplayExtraWarnings; to show more details on individual variables. ************* Simulation Error Summary ************* ************* There are 1 unused objects in input. ************* Use Output:Diagnostics,DisplayUnusedObjects; to see them. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors. ************* EnergyPlus Completed Successfully-- 26 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 6.36sec