Program Version:EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2023.12.28 13:46

Tabular Output Report in Format: HTML

Building: Buildings in b'Montreal'

Environment: RUN PERIOD 1 ** Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270

Simulation Timestamp: 2023-12-28 13:46:25


Table of Contents

Report: Annual Building Utility Performance Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Values gathered over 8760.00 hours



Site and Source Energy

Total Energy [kWh] Energy Per Total Building Area [kWh/m2] Energy Per Conditioned Building Area [kWh/m2]
Total Site Energy 2653936.76 821.38 821.38
Net Site Energy 2653936.76 821.38 821.38
Total Source Energy 8680338.22 2686.51 2686.51
Net Source Energy 8680338.22 2686.51 2686.51


Site to Source Energy Conversion Factors

Site=>Source Conversion Factor
Electricity 3.167
Natural Gas 1.084
District Cooling 1.056
District Heating 3.613
Steam 1.200
Gasoline 1.050
Diesel 1.050
Coal 1.050
Fuel Oil No 1 1.050
Fuel Oil No 2 1.050
Propane 1.050
Other Fuel 1 1.000
Other Fuel 2 1.000


Building Area

Area [m2]
Total Building Area 3231.08
Net Conditioned Building Area 3231.08
Unconditioned Building Area 0.00


End Uses

Electricity [kWh] Natural Gas [kWh] Gasoline [kWh] Diesel [kWh] Coal [kWh] Fuel Oil No 1 [kWh] Fuel Oil No 2 [kWh] Propane [kWh] Other Fuel 1 [kWh] Other Fuel 2 [kWh] District Cooling [kWh] District Heating [kWh] Water [m3]
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 892105.77 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 279072.25 0.00 0.00
Interior Lighting 160943.89 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 276948.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1044865.94 14754.10
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 437892.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 279072.25 1936971.72 14754.10
Note: District heat appears to be the principal heating source based on energy usage.

End Uses By Subcategory

Subcategory Electricity [kWh] Natural Gas [kWh] Gasoline [kWh] Diesel [kWh] Coal [kWh] Fuel Oil No 1 [kWh] Fuel Oil No 2 [kWh] Propane [kWh] Other Fuel 1 [kWh] Other Fuel 2 [kWh] District Cooling [kWh] District Heating [kWh] Water [m3]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 892105.77 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 279072.25 0.00 0.00
Interior Lighting ELECTRIC EQUIPMENT#173347#GeneralLights 2984.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#173348#GeneralLights 3190.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#175012#GeneralLights 129831.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176261#GeneralLights 3125.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176296#GeneralLights 3271.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#177698#GeneralLights 3258.93 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#178164#GeneralLights 2969.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181359#GeneralLights 3006.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181706#GeneralLights 3292.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183144#GeneralLights 3023.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183243#GeneralLights 2989.39 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment ELECTRIC EQUIPMENT#173347#InteriorEquipment 5135.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#173348#InteriorEquipment 5489.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#175012#InteriorEquipment 223411.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176261#InteriorEquipment 5378.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176296#InteriorEquipment 5629.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#177698#InteriorEquipment 5607.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#178164#InteriorEquipment 5110.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181359#InteriorEquipment 5173.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181706#InteriorEquipment 5666.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183144#InteriorEquipment 5202.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183243#InteriorEquipment 5144.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems DHW 173347 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 19375.90 273.60
  DHW 173348 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20710.91 292.45
  DHW 175012 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 842883.07 11901.99
  DHW 176261 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20290.27 286.51
  DHW 176296 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21239.25 299.91
  DHW 177698 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21157.35 298.75
  DHW 178164 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 19280.26 272.25
  DHW 181359 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 19517.09 275.59
  DHW 181706 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21377.91 301.87
  DHW 183144 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 19626.49 277.14
  DHW 183243 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 19407.44 274.04
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00


Normalized Metrics

Utility Use Per Conditioned Floor Area

Electricity Intensity [kWh/m2] Natural Gas Intensity [kWh/m2] Gasoline Intensity [kWh/m2] Diesel Intensity [kWh/m2] Coal Intensity [kWh/m2] Fuel Oil No 1 Intensity [kWh/m2] Fuel Oil No 2 Intensity [kWh/m2] Propane Intensity [kWh/m2] Other Fuel 1 Intensity [kWh/m2] Other Fuel 2 Intensity [kWh/m2] District Cooling Intensity [kWh/m2] District Heating Intensity [kWh/m2] Water Intensity [m3/m2]
Lighting 49.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 86.37 599.48 4.57
Other 85.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 135.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 86.37 599.48 4.57


Utility Use Per Total Floor Area

Electricity Intensity [kWh/m2] Natural Gas Intensity [kWh/m2] Gasoline Intensity [kWh/m2] Diesel Intensity [kWh/m2] Coal Intensity [kWh/m2] Fuel Oil No 1 Intensity [kWh/m2] Fuel Oil No 2 Intensity [kWh/m2] Propane Intensity [kWh/m2] Other Fuel 1 Intensity [kWh/m2] Other Fuel 2 Intensity [kWh/m2] District Cooling Intensity [kWh/m2] District Heating Intensity [kWh/m2] Water Intensity [m3/m2]
Lighting 49.81 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
HVAC 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 86.37 599.48 4.57
Other 85.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total 135.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 86.37 599.48 4.57


Electric Loads Satisfied

Electricity [kWh] Percent Electricity [%]
Fuel-Fired Power Generation 0.000 0.00
High Temperature Geothermal* 0.000 0.00
Photovoltaic Power 0.000 0.00
Wind Power 0.000 0.00
Power Conversion 0.000 0.00
Net Decrease in On-Site Storage 0.000 0.00
Total On-Site Electric Sources 0.000 0.00
     
Electricity Coming From Utility 437892.795 100.00
Surplus Electricity Going To Utility 0.000 0.00
Net Electricity From Utility 437892.795 100.00
     
Total On-Site and Utility Electric Sources 437892.795 100.00
Total Electricity End Uses 437892.795 100.00


On-Site Thermal Sources

Heat [kWh] Percent Heat [%]
Water-Side Heat Recovery 0.00  
Air to Air Heat Recovery for Cooling 0.00  
Air to Air Heat Recovery for Heating 0.00  
High-Temperature Geothermal* 0.00  
Solar Water Thermal 0.00  
Solar Air Thermal 0.00  
Total On-Site Thermal Sources 0.00  


Water Source Summary

Water [m3] Percent Water [%]
Rainwater Collection 0.00 0.00
Condensate Collection 0.00 0.00
Groundwater Well 0.00 0.00
Total On Site Water Sources 0.00 0.00
- - -
Initial Storage 0.00 0.00
Final Storage 0.00 0.00
Change in Storage 0.00 0.00
- - -
Water Supplied by Utility 14754.10 100.00
- - -
Total On Site, Change in Storage, and Utility Water Sources 14754.10 100.00
Total Water End Uses 14754.10 100.00


Setpoint Not Met Criteria

Degrees [deltaC]
Tolerance for Zone Heating Setpoint Not Met Time 0.20
Tolerance for Zone Cooling Setpoint Not Met Time 0.20


Comfort and Setpoint Not Met Summary

Facility [Hours]
Time Setpoint Not Met During Occupied Heating 0.00
Time Setpoint Not Met During Occupied Cooling 0.00
Time Not Comfortable Based on Simple ASHRAE 55-2004 5440.25


Note 1: An asterisk (*) indicates that the feature is not yet implemented.

Table of Contents

Top
Annual Building Utility Performance Summary
Input Verification and Results Summary
Demand End Use Components Summary
Component Sizing Summary
Adaptive Comfort Summary
Climatic Data Summary
Envelope Summary
Lighting Summary
Equipment Summary
HVAC Sizing Summary
System Summary
Outdoor Air Summary
Object Count Summary
Sensible Heat Gain Summary

Table of Contents

Report: Input Verification and Results Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

General

Value
Program Version and Build EnergyPlus, Version 9.5.0-de239b2e5f, YMD=2023.12.28 13:46
RunPeriod RUN PERIOD 1
Weather File Montreal Int'l PQ CAN WYEC2-B-94792 WMO#=716270
Latitude [deg] 45.47
Longitude [deg] -73.8
Elevation [m] 36.00
Time Zone -5.0
North Axis Angle [deg] 0.00
Rotation for Appendix G [deg] 0.00
Hours Simulated [hrs] 8760.00


ENVELOPE

Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 6266.10 1543.40 1582.77 1562.76 1577.17
Above Ground Wall Area [m2] 6266.10 1543.40 1582.77 1562.76 1577.17
Window Opening Area [m2] 1128.02 277.84 284.93 281.33 283.92
Gross Window-Wall Ratio [%] 18.00 18.00 18.00 18.00 18.00
Above Ground Window-Wall Ratio [%] 18.00 18.00 18.00 18.00 18.00


Conditioned Window-Wall Ratio

Total North (315 to 45 deg) East (45 to 135 deg) South (135 to 225 deg) West (225 to 315 deg)
Gross Wall Area [m2] 6266.10 1543.40 1582.77 1562.76 1577.17
Above Ground Wall Area [m2] 6266.10 1543.40 1582.77 1562.76 1577.17
Window Opening Area [m2] 1128.02 277.84 284.93 281.33 283.92
Gross Window-Wall Ratio [%] 18.00 18.00 18.00 18.00 18.00
Above Ground Window-Wall Ratio [%] 18.00 18.00 18.00 18.00 18.00


Skylight-Roof Ratio

Total
Gross Roof Area [m2] 3231.08
Skylight Area [m2] 0.00
Skylight-Roof Ratio [%] 0.00


PERFORMANCE

Zone Summary

Area [m2] Conditioned (Y/N) Part of Total Floor Area (Y/N) Volume [m3] Multipliers Above Ground Gross Wall Area [m2] Underground Gross Wall Area [m2] Window Glass Area [m2] Opening Area [m2] Lighting [W/m2] People [m2 per person] Plug and Process [W/m2]
173347 88.46 Yes Yes 796.15 1.00 114.83 0.00 20.67 20.67 16.5060 8.33 15.0055
173348 94.56 Yes Yes 851.01 1.00 247.74 0.00 44.60 44.60 16.5060 8.33 15.0055
175012 2308.92 Yes Yes 34633.86 1.00 4240.33 0.00 763.34 763.34 27.5100 5.00 25.0091
176261 92.64 Yes Yes 926.36 1.00 278.66 0.00 50.16 50.16 16.5060 8.33 15.0055
176296 96.97 Yes Yes 969.68 1.00 423.43 0.00 76.23 76.23 16.5060 8.33 15.0055
177698 96.59 Yes Yes 869.35 1.00 249.95 0.00 45.00 45.00 16.5060 8.33 15.0055
178164 88.02 Yes Yes 792.22 1.00 114.82 0.00 20.67 20.67 16.5060 8.33 15.0055
181359 89.11 Yes Yes 801.95 1.00 114.83 0.00 20.67 20.67 16.5060 8.33 15.0055
181706 97.60 Yes Yes 878.41 1.00 251.85 0.00 45.34 45.34 16.5060 8.33 15.0055
183144 89.61 Yes Yes 806.45 1.00 114.83 0.00 20.67 20.67 16.5060 8.33 15.0055
183243 88.61 Yes Yes 797.45 1.00 114.83 0.00 20.67 20.67 16.5060 8.33 15.0055
Total 3231.08     43122.90   6266.10 0.00 1128.02 1128.02 24.3694 5.64 22.1540
Conditioned Total 3231.08     43122.90   6266.10 0.00 1128.02 1128.02 24.3694 5.64 22.1540
Unconditioned Total 0.00     0.00   0.00 0.00 0.00 0.00      
Not Part of Total 0.00     0.00   0.00 0.00 0.00 0.00      



Table of Contents

Report: Demand End Use Components Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

End Uses

Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] District Heating [W] Water [m3/s]
Time of Peak 01-JAN-19:15 - - - - - - - - - 20-JUL-19:15 04-FEB-07:15 20-JUL-16:15
Heating 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 603528.23 0.00
Cooling 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 389437.31 0.00 0.00
Interior Lighting 70865.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment 64423.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 285491.04 0.00
Refrigeration 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
                           
Total End Uses 135289.07 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 389437.31 889019.28 0.00


End Uses By Subcategory

Subcategory Electricity [W] Natural Gas [W] Gasoline [W] Diesel [W] Coal [W] Fuel Oil No 1 [W] Fuel Oil No 2 [W] Propane [W] Other Fuel 1 [W] Other Fuel 2 [W] District Cooling [W] District Heating [W] Water [m3/s]
Heating General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 603528.23 0.00
Cooling General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 389437.31 0.00 0.00
Interior Lighting ELECTRIC EQUIPMENT#173347#GeneralLights 1314.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#173348#GeneralLights 1404.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#175012#GeneralLights 57166.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176261#GeneralLights 1376.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176296#GeneralLights 1440.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#177698#GeneralLights 1434.95 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#178164#GeneralLights 1307.64 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181359#GeneralLights 1323.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181706#GeneralLights 1449.91 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183144#GeneralLights 1331.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183243#GeneralLights 1316.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Lighting General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Interior Equipment ELECTRIC EQUIPMENT#173347#InteriorEquipment 1194.66 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#173348#InteriorEquipment 1276.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#175012#InteriorEquipment 51969.70 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176261#InteriorEquipment 1251.04 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#176296#InteriorEquipment 1309.55 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#177698#InteriorEquipment 1304.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#178164#InteriorEquipment 1188.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181359#InteriorEquipment 1203.37 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#181706#InteriorEquipment 1318.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183144#InteriorEquipment 1210.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  ELECTRIC EQUIPMENT#183243#InteriorEquipment 1196.61 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Exterior Equipment General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fans Ventilation (simple) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Pumps General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Rejection General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Humidification General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Heat Recovery General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Water Systems DHW 173347 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5294.12 0.00
  DHW 173348 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5658.89 0.00
  DHW 175012 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 230302.82 0.00
  DHW 176261 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5543.96 0.00
  DHW 176296 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5803.25 0.00
  DHW 177698 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5780.87 0.00
  DHW 178164 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5267.99 0.00
  DHW 181359 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5332.70 0.00
  DHW 181706 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5841.13 0.00
  DHW 183144 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5362.59 0.00
  DHW 183243 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5302.74 0.00
Refrigeration General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Generators General 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00



Table of Contents

Report: Component Sizing Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25


Table of Contents

Report: Adaptive Comfort Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Time Not Meeting the Adaptive Comfort Models during Occupied Hours

ASHRAE55 90% Acceptability Limits [Hours] ASHRAE55 80% Acceptability Limits [Hours] CEN15251 Category I Acceptability Limits [Hours] CEN15251 Category II Acceptability Limits [Hours] CEN15251 Category III Acceptability Limits [Hours]



Table of Contents

Report: Climatic Data Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

SizingPeriod:DesignDay

Maximum Dry Bulb [C] Daily Temperature Range [deltaC] Humidity Value Humidity Type Wind Speed [m/s] Wind Direction
None            


Weather Statistics File

Value
None  



Table of Contents

Report: Envelope Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Opaque Exterior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
597E8893-BF63-4356-83EB-581A544045AC 1981_1990_6 0.40 0.644 0.713 57.41 47.08 90.32 90.00 E
E9F9F468-BE3C-406C-A131-151A54D54C3B 1981_1990_6 0.40 0.644 0.713 57.41 47.08 269.70 90.00 W
5B48231E-B210-48CA-BFF3-62C8D8E642CD 1981_1990_6 0.40 0.639 0.713 88.46 88.46 0.14 180.00  
5090EE93-FEFB-418C-B8E3-C35CC3106B55 1981_1990_6 0.40 0.649 0.713 88.46 88.46 0.14 0.00  
81D97B28-7FE0-47F3-A8EF-DBC87B6FA485 1981_1990_6 0.40 0.644 0.713 51.38 42.13 90.32 90.00 E
465F65FE-61CA-4913-AA63-BD2BAD166056 1981_1990_6 0.40 0.644 0.713 9.77 8.01 89.91 90.00 E
D4DDF175-8CE1-4DE4-920D-9E87760A2357 1981_1990_6 0.40 0.644 0.713 120.90 99.13 0.06 90.00 N
CD9C1CCB-94C4-4D52-918E-02B6D9F23CD6 1981_1990_6 0.40 0.644 0.713 4.80 3.93 359.13 90.00 N
B8E5722F-137A-4265-A0C8-4477DACE4464 1981_1990_6 0.40 0.644 0.713 60.89 49.93 269.70 90.00 W
3F6836B3-3739-4EB7-A50F-6B1EC2695C69 1981_1990_6 0.40 0.639 0.713 94.56 94.56 270.32 180.00  
CADC5B75-BB4B-46D4-9B46-CB298FC508E4 1981_1990_6 0.40 0.649 0.713 94.56 94.56 89.91 0.00  
7D0C86B4-2C88-4226-8256-72C260ECE0BD 1981_1990_6 0.40 0.644 0.713 269.34 220.85 270.37 90.00 W
AA54AC6D-9DE4-4186-B260-051460D41D27 1981_1990_6 0.40 0.644 0.713 42.68 35.00 0.73 90.00 N
9E618400-85C5-496B-A5FA-54781BA43CEF 1981_1990_6 0.40 0.644 0.713 50.71 41.58 269.95 90.00 W
8CC9A5F8-7042-4266-B52C-96552E8171FD 1981_1990_6 0.40 0.644 0.713 33.05 27.10 0.68 90.00 N
BD015AC2-ED48-45A8-AFF2-AAA3F0E7E0F8 1981_1990_6 0.40 0.644 0.713 330.80 271.25 270.63 90.00 W
51CACE5A-D4F2-4D1B-ACB5-FFDBAF04A5E3 1981_1990_6 0.40 0.644 0.713 8.84 7.25 271.07 90.00 W
CCB7F46B-11E3-47EF-9D74-515E3A60294A 1981_1990_6 0.40 0.644 0.713 37.21 30.51 180.88 90.00 S
3F743FC3-A3AF-44B1-8C5B-8A239C7A0DF1 1981_1990_6 0.40 0.644 0.713 48.45 39.73 270.81 90.00 W
2A3D3C01-7AC9-49C3-9D0F-CCC7112F80E7 1981_1990_6 0.40 0.644 0.713 50.23 41.19 180.83 90.00 S
404B2F49-3137-4D51-9B65-BA17039744A7 1981_1990_6 0.40 0.644 0.713 264.28 216.70 270.81 90.00 W
5E512775-1BB9-4BFF-B0C1-56B547F0A8DF 1981_1990_6 0.40 0.644 0.713 547.94 449.30 180.80 90.00 S
E8D59443-A80D-4458-8F69-7EF4938D44C7 1981_1990_6 0.40 0.644 0.713 8.10 6.64 181.90 90.00 S
F90B3E61-9004-40B2-A979-81DAB0B99469 1981_1990_6 0.40 0.644 0.713 16.36 13.41 90.30 90.00 E
334BAEB1-D3D8-43BC-9D18-8C8D5497B950 1981_1990_6 0.40 0.644 0.713 71.03 58.24 180.36 90.00 S
F2773F25-BF65-4CE3-89EC-CA874375AA3F 1981_1990_6 0.40 0.644 0.713 332.92 272.99 90.35 90.00 E
1CA10200-62C5-402B-909C-83A2A86AC628 1981_1990_6 0.40 0.644 0.713 438.53 359.59 0.36 90.00 N
CACC7EAD-4051-4299-A3FE-A21BD1EA6C93 1981_1990_6 0.40 0.644 0.713 282.91 231.98 90.36 90.00 E
8278B81D-4747-472F-A7F3-0F5F4834369E 1981_1990_6 0.40 0.644 0.713 432.84 354.92 180.36 90.00 S
EA7A188E-C0DD-41FB-AFFB-5546DD3ED8A0 1981_1990_6 0.40 0.644 0.713 344.94 282.84 90.36 90.00 E
5E175F67-94FE-490D-AD22-13AD9EA2F624 1981_1990_6 0.40 0.644 0.713 629.18 515.91 0.35 90.00 N
C53FC572-BF34-408F-8F51-C400DE236CBC 1981_1990_6 0.40 0.639 0.713 2308.92 2308.92 0.36 180.00  
57B878DC-1779-436B-9756-55C0AF76D50E 1981_1990_6 0.40 0.649 0.713 2308.92 2308.92 0.36 0.00  
8F1314AA-7CA7-4107-BFD4-E601556F45F2 1981_1990_6 0.40 0.644 0.713 5.62 4.61 358.71 90.00 N
996A84C5-812F-403B-879D-7233B65AA66F 1981_1990_6 0.40 0.644 0.713 4.45 3.65 90.31 90.00 E
48618736-DEE0-4588-AFDF-D82A1EC13FB0 1981_1990_6 0.40 0.644 0.713 65.43 53.65 269.70 90.00 W
C4EA0EBA-E459-4E6E-BC40-59E57B9A1AB5 1981_1990_6 0.40 0.644 0.713 143.18 117.41 179.68 90.00 S
96E4C93A-7D73-4F02-A1B0-1BA8B18682D1 1981_1990_6 0.40 0.644 0.713 59.97 49.18 89.74 90.00 E
DAAFBE38-0BB6-4E78-99D8-A24D93683C5F 1981_1990_6 0.40 0.639 0.713 92.64 92.64 359.68 180.00  
88AC3937-911D-427D-9291-68DA65F3AD67 1981_1990_6 0.40 0.649 0.713 92.64 92.64 358.71 0.00  
E2ECFD8B-F3B6-4753-A361-6F442C491E6C 1981_1990_6 0.40 0.644 0.713 67.25 55.14 90.03 90.00 E
DA9F4734-38C4-42B7-8862-1E510B356BD9 1981_1990_6 0.40 0.644 0.713 144.70 118.65 359.95 90.00 N
C860B96F-077E-4B02-A9F9-B55670FD477B 1981_1990_6 0.40 0.644 0.713 66.78 54.75 270.04 90.00 W
480A21AF-85AE-4059-B848-33FD5F3A5720 1981_1990_6 0.40 0.644 0.713 144.71 118.66 180.13 90.00 S
7581E7C1-7442-4E57-B277-4F8CA5FDF4C0 1981_1990_6 0.40 0.639 0.713 96.97 96.97 0.13 180.00  
49E69C19-AA91-4925-98AC-D68299566337 1981_1990_6 0.40 0.649 0.713 96.97 96.97 359.95 0.00  
DB1D1E20-BE98-49D4-9E40-1940144BF615 1981_1990_6 0.40 0.644 0.713 4.42 3.62 90.22 90.00 E
8FC429BC-81D9-449A-80A9-38F77B3E66DD 1981_1990_6 0.40 0.644 0.713 118.69 97.33 359.45 90.00 N
759D0D84-9F31-46A9-AB0C-A80AF93CD9F9 1981_1990_6 0.40 0.644 0.713 5.25 4.31 0.34 90.00 N
2FB34A99-C1EA-45CB-A3BE-D36736D9F6D4 1981_1990_6 0.40 0.644 0.713 62.29 51.08 270.10 90.00 W
5EC4A61B-3773-449F-B181-753456E72C34 1981_1990_6 0.40 0.644 0.713 59.29 48.62 89.40 90.00 E
1F2698C6-9AB2-4092-8689-F48F27F007F3 1981_1990_6 0.40 0.639 0.713 96.59 96.59 269.40 180.00  
C421315B-3FA6-4F26-8FE4-2BD36E46C018 1981_1990_6 0.40 0.649 0.713 96.59 96.59 90.22 0.00  
D9F477EB-A2BB-45DC-80C6-F24D09A96A5C 1981_1990_6 0.40 0.644 0.713 57.41 47.08 90.32 90.00 E
12B9DB48-E074-4E87-8478-9A8221BFECE1 1981_1990_6 0.40 0.644 0.713 57.41 47.08 269.70 90.00 W
0F842809-D03C-47DA-A397-CC369EC4D39B 1981_1990_6 0.40 0.639 0.713 88.02 88.02 0.14 180.00  
9A1D52B6-CA21-44CB-8234-487282B053CE 1981_1990_6 0.40 0.649 0.713 88.02 88.02 0.14 0.00  
D15932BE-B61F-4D05-8F3D-A538ADA1C1B9 1981_1990_6 0.40 0.644 0.713 57.42 47.08 89.40 90.00 E
D7BFAC7E-FFE4-43E5-A664-66123D42D5E0 1981_1990_6 0.40 0.644 0.713 57.41 47.08 270.10 90.00 W
F1D05492-FC37-4CE7-B4BE-AB84E65BBA2D 1981_1990_6 0.40 0.639 0.713 89.11 89.11 0.14 180.00  
549077E1-BF77-47A7-AFFB-E487658423CC 1981_1990_6 0.40 0.649 0.713 89.11 89.11 0.14 0.00  
88E8F7FF-619E-4595-81EB-D5BAD7867696 1981_1990_6 0.40 0.644 0.713 62.03 50.86 89.40 90.00 E
28CE80FE-FE76-466F-A7EB-88A00D656F05 1981_1990_6 0.40 0.644 0.713 62.29 51.08 270.10 90.00 W
F5F1247A-88BE-4F06-B629-4C3613F82D51 1981_1990_6 0.40 0.644 0.713 123.20 101.02 180.04 90.00 S
B8CB1843-0410-4673-BFD4-5DC3C73F2BDD 1981_1990_6 0.40 0.644 0.713 4.34 3.55 179.52 90.00 S
EC0278F6-DA80-4F16-8DE4-BB9973EBB3B2 1981_1990_6 0.40 0.639 0.713 97.60 97.60 359.52 180.00  
DC07A81C-DAB5-45F7-BEE5-80767931DBC0 1981_1990_6 0.40 0.649 0.713 97.60 97.60 0.14 0.00  
23571505-EC9B-43AD-BFCA-E0997E7A40A6 1981_1990_6 0.40 0.644 0.713 57.42 47.08 89.40 90.00 E
ED2B8CED-C770-4499-B4D2-1F89BA80E037 1981_1990_6 0.40 0.644 0.713 57.41 47.08 270.10 90.00 W
5B52E826-42B4-4A00-9549-10196A13F76D 1981_1990_6 0.40 0.639 0.713 89.61 89.61 0.14 180.00  
36849036-C5B5-40B7-8F21-F853A75F082B 1981_1990_6 0.40 0.649 0.713 89.61 89.61 0.14 0.00  
39CD3473-FBC3-431F-B595-088111688FF0 1981_1990_6 0.40 0.644 0.713 57.42 47.08 89.40 90.00 E
E3C38143-FDEB-4CAD-BFDE-4855A94C5FFE 1981_1990_6 0.40 0.644 0.713 57.41 47.08 270.10 90.00 W
CC5D3CDE-CC73-4B55-9BE2-DA25001A6EA6 1981_1990_6 0.40 0.639 0.713 88.61 88.61 0.14 180.00  
BC98B527-A9A7-4167-8D48-AD07E222751B 1981_1990_6 0.40 0.649 0.713 88.61 88.61 0.14 0.00  


Opaque Interior

Construction Reflectance U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Net Area [m2] Azimuth [deg] Tilt [deg] Cardinal Direction
500F7547-EA7A-498B-8000-CC091AFCE755 1981_1990_6 0.40 0.609 0.713 125.11 125.11 0.14 90.00 N
398D7259-ACD4-4A78-B8DD-F50A483BBA9D 1981_1990_6 0.40 0.609 0.713 124.50 124.50 180.14 90.00 S
6AC6AA25-5E89-4029-9946-74804658CAF4 1981_1990_6 0.40 0.609 0.713 125.11 125.11 180.14 90.00 S
84E6204F-F657-41CA-BD9C-FF8DD55FDCD9 1981_1990_6 0.40 0.609 0.713 137.65 137.65 0.14 90.00 N
8DFBD53D-371B-4A6F-9422-D041D8AADF88 1981_1990_6 0.40 0.609 0.713 124.66 124.66 180.14 90.00 S
4A29AC31-F3CA-4AE3-AF0C-5D2899DDD309 1981_1990_6 0.40 0.609 0.713 124.50 124.50 0.14 90.00 N
1542594C-4A08-4E29-BBB6-BF6798DD1E56 1981_1990_6 0.40 0.609 0.713 123.89 123.89 180.14 90.00 S
F72F957D-1E74-40BC-B6CB-D42C2B474277 1981_1990_6 0.40 0.609 0.713 125.36 125.36 0.14 90.00 N
53505FE8-5ADB-4B73-BD6C-955D322B0A64 1981_1990_6 0.40 0.609 0.713 126.07 126.07 180.14 90.00 S
744EAE42-6F20-4700-9BFC-85DD929A297D 1981_1990_6 0.40 0.609 0.713 126.77 126.77 0.14 90.00 N
CB1B4365-3338-4050-8DE9-CBD4EBF6ACE2 1981_1990_6 0.40 0.609 0.713 126.07 126.07 0.14 90.00 N
7FA395E8-2B05-448A-B1B1-9CA854CD4CDB 1981_1990_6 0.40 0.609 0.713 126.77 126.77 180.14 90.00 S
E8EAF434-D518-420C-A1AE-4F9AC185C3C7 1981_1990_6 0.40 0.609 0.713 124.66 124.66 0.14 90.00 N
E2AF1629-BF60-4BA4-B83F-DA0427CC5520 1981_1990_6 0.40 0.609 0.713 125.36 125.36 180.14 90.00 S


Exterior Fenestration

Construction Glass Area [m2] Frame Area [m2] Divider Area [m2] Area of One Opening [m2] Area of Multiplied Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Frame Conductance [W/m2-K] Divider Conductance [W/m2-K] Shade Control Parent Surface Azimuth [deg] Tilt [deg] Cardinal Direction
597E8893-BF63-4356-83EB-581A544045AC WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No 597E8893-BF63-4356-83EB-581A544045AC 90.32 90.00 E
E9F9F468-BE3C-406C-A131-151A54D54C3B WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No E9F9F468-BE3C-406C-A131-151A54D54C3B 269.70 90.00 W
81D97B28-7FE0-47F3-A8EF-DBC87B6FA485 WINDOW WINDOW_CONSTRUCTION_1 9.25 0.00 0.00 9.25 9.25 2.954 0.391 0.305     No 81D97B28-7FE0-47F3-A8EF-DBC87B6FA485 90.32 90.00 E
465F65FE-61CA-4913-AA63-BD2BAD166056 WINDOW WINDOW_CONSTRUCTION_1 1.76 0.00 0.00 1.76 1.76 2.954 0.391 0.305     No 465F65FE-61CA-4913-AA63-BD2BAD166056 89.91 90.00 E
D4DDF175-8CE1-4DE4-920D-9E87760A2357 WINDOW WINDOW_CONSTRUCTION_1 21.76 0.00 0.00 21.76 21.76 2.954 0.391 0.305     No D4DDF175-8CE1-4DE4-920D-9E87760A2357 0.06 90.00 N
CD9C1CCB-94C4-4D52-918E-02B6D9F23CD6 WINDOW WINDOW_CONSTRUCTION_1 0.86 0.00 0.00 0.86 0.86 2.954 0.391 0.305     No CD9C1CCB-94C4-4D52-918E-02B6D9F23CD6 359.13 90.00 N
B8E5722F-137A-4265-A0C8-4477DACE4464 WINDOW WINDOW_CONSTRUCTION_1 10.96 0.00 0.00 10.96 10.96 2.954 0.391 0.305     No B8E5722F-137A-4265-A0C8-4477DACE4464 269.70 90.00 W
7D0C86B4-2C88-4226-8256-72C260ECE0BD WINDOW WINDOW_CONSTRUCTION_1 48.49 0.00 0.00 48.49 48.49 2.954 0.391 0.305     No 7D0C86B4-2C88-4226-8256-72C260ECE0BD 270.37 90.00 W
AA54AC6D-9DE4-4186-B260-051460D41D27 WINDOW WINDOW_CONSTRUCTION_1 7.68 0.00 0.00 7.68 7.68 2.954 0.391 0.305     No AA54AC6D-9DE4-4186-B260-051460D41D27 0.73 90.00 N
9E618400-85C5-496B-A5FA-54781BA43CEF WINDOW WINDOW_CONSTRUCTION_1 9.13 0.00 0.00 9.13 9.13 2.954 0.391 0.305     No 9E618400-85C5-496B-A5FA-54781BA43CEF 269.95 90.00 W
8CC9A5F8-7042-4266-B52C-96552E8171FD WINDOW WINDOW_CONSTRUCTION_1 5.95 0.00 0.00 5.95 5.95 2.954 0.391 0.305     No 8CC9A5F8-7042-4266-B52C-96552E8171FD 0.68 90.00 N
BD015AC2-ED48-45A8-AFF2-AAA3F0E7E0F8 WINDOW WINDOW_CONSTRUCTION_1 59.55 0.00 0.00 59.55 59.55 2.954 0.391 0.305     No BD015AC2-ED48-45A8-AFF2-AAA3F0E7E0F8 270.63 90.00 W
51CACE5A-D4F2-4D1B-ACB5-FFDBAF04A5E3 WINDOW WINDOW_CONSTRUCTION_1 1.59 0.00 0.00 1.59 1.59 2.954 0.391 0.305     No 51CACE5A-D4F2-4D1B-ACB5-FFDBAF04A5E3 271.07 90.00 W
CCB7F46B-11E3-47EF-9D74-515E3A60294A WINDOW WINDOW_CONSTRUCTION_1 6.70 0.00 0.00 6.70 6.70 2.954 0.391 0.305     No CCB7F46B-11E3-47EF-9D74-515E3A60294A 180.88 90.00 S
3F743FC3-A3AF-44B1-8C5B-8A239C7A0DF1 WINDOW WINDOW_CONSTRUCTION_1 8.72 0.00 0.00 8.72 8.72 2.954 0.391 0.305     No 3F743FC3-A3AF-44B1-8C5B-8A239C7A0DF1 270.81 90.00 W
2A3D3C01-7AC9-49C3-9D0F-CCC7112F80E7 WINDOW WINDOW_CONSTRUCTION_1 9.04 0.00 0.00 9.04 9.04 2.954 0.391 0.305     No 2A3D3C01-7AC9-49C3-9D0F-CCC7112F80E7 180.83 90.00 S
404B2F49-3137-4D51-9B65-BA17039744A7 WINDOW WINDOW_CONSTRUCTION_1 47.57 0.00 0.00 47.57 47.57 2.954 0.391 0.305     No 404B2F49-3137-4D51-9B65-BA17039744A7 270.81 90.00 W
5E512775-1BB9-4BFF-B0C1-56B547F0A8DF WINDOW WINDOW_CONSTRUCTION_1 98.64 0.00 0.00 98.64 98.64 2.954 0.391 0.305     No 5E512775-1BB9-4BFF-B0C1-56B547F0A8DF 180.80 90.00 S
E8D59443-A80D-4458-8F69-7EF4938D44C7 WINDOW WINDOW_CONSTRUCTION_1 1.46 0.00 0.00 1.46 1.46 2.954 0.391 0.305     No E8D59443-A80D-4458-8F69-7EF4938D44C7 181.90 90.00 S
F90B3E61-9004-40B2-A979-81DAB0B99469 WINDOW WINDOW_CONSTRUCTION_1 2.94 0.00 0.00 2.94 2.94 2.954 0.391 0.305     No F90B3E61-9004-40B2-A979-81DAB0B99469 90.30 90.00 E
334BAEB1-D3D8-43BC-9D18-8C8D5497B950 WINDOW WINDOW_CONSTRUCTION_1 12.79 0.00 0.00 12.79 12.79 2.954 0.391 0.305     No 334BAEB1-D3D8-43BC-9D18-8C8D5497B950 180.36 90.00 S
F2773F25-BF65-4CE3-89EC-CA874375AA3F WINDOW WINDOW_CONSTRUCTION_1 59.93 0.00 0.00 59.93 59.93 2.954 0.391 0.305     No F2773F25-BF65-4CE3-89EC-CA874375AA3F 90.35 90.00 E
1CA10200-62C5-402B-909C-83A2A86AC628 WINDOW WINDOW_CONSTRUCTION_1 78.94 0.00 0.00 78.94 78.94 2.954 0.391 0.305     No 1CA10200-62C5-402B-909C-83A2A86AC628 0.36 90.00 N
CACC7EAD-4051-4299-A3FE-A21BD1EA6C93 WINDOW WINDOW_CONSTRUCTION_1 50.93 0.00 0.00 50.93 50.93 2.954 0.391 0.305     No CACC7EAD-4051-4299-A3FE-A21BD1EA6C93 90.36 90.00 E
8278B81D-4747-472F-A7F3-0F5F4834369E WINDOW WINDOW_CONSTRUCTION_1 77.92 0.00 0.00 77.92 77.92 2.954 0.391 0.305     No 8278B81D-4747-472F-A7F3-0F5F4834369E 180.36 90.00 S
EA7A188E-C0DD-41FB-AFFB-5546DD3ED8A0 WINDOW WINDOW_CONSTRUCTION_1 62.10 0.00 0.00 62.10 62.10 2.954 0.391 0.305     No EA7A188E-C0DD-41FB-AFFB-5546DD3ED8A0 90.36 90.00 E
5E175F67-94FE-490D-AD22-13AD9EA2F624 WINDOW WINDOW_CONSTRUCTION_1 113.26 0.00 0.00 113.26 113.26 2.954 0.391 0.305     No 5E175F67-94FE-490D-AD22-13AD9EA2F624 0.35 90.00 N
8F1314AA-7CA7-4107-BFD4-E601556F45F2 WINDOW WINDOW_CONSTRUCTION_1 1.01 0.00 0.00 1.01 1.01 2.954 0.391 0.305     No 8F1314AA-7CA7-4107-BFD4-E601556F45F2 358.71 90.00 N
996A84C5-812F-403B-879D-7233B65AA66F WINDOW WINDOW_CONSTRUCTION_1 0.80 0.00 0.00 0.80 0.80 2.954 0.391 0.305     No 996A84C5-812F-403B-879D-7233B65AA66F 90.31 90.00 E
48618736-DEE0-4588-AFDF-D82A1EC13FB0 WINDOW WINDOW_CONSTRUCTION_1 11.78 0.00 0.00 11.78 11.78 2.954 0.391 0.305     No 48618736-DEE0-4588-AFDF-D82A1EC13FB0 269.70 90.00 W
C4EA0EBA-E459-4E6E-BC40-59E57B9A1AB5 WINDOW WINDOW_CONSTRUCTION_1 25.78 0.00 0.00 25.78 25.78 2.954 0.391 0.305     No C4EA0EBA-E459-4E6E-BC40-59E57B9A1AB5 179.68 90.00 S
96E4C93A-7D73-4F02-A1B0-1BA8B18682D1 WINDOW WINDOW_CONSTRUCTION_1 10.80 0.00 0.00 10.80 10.80 2.954 0.391 0.305     No 96E4C93A-7D73-4F02-A1B0-1BA8B18682D1 89.74 90.00 E
E2ECFD8B-F3B6-4753-A361-6F442C491E6C WINDOW WINDOW_CONSTRUCTION_1 12.11 0.00 0.00 12.11 12.11 2.954 0.391 0.305     No E2ECFD8B-F3B6-4753-A361-6F442C491E6C 90.03 90.00 E
DA9F4734-38C4-42B7-8862-1E510B356BD9 WINDOW WINDOW_CONSTRUCTION_1 26.05 0.00 0.00 26.05 26.05 2.954 0.391 0.305     No DA9F4734-38C4-42B7-8862-1E510B356BD9 359.95 90.00 N
C860B96F-077E-4B02-A9F9-B55670FD477B WINDOW WINDOW_CONSTRUCTION_1 12.02 0.00 0.00 12.02 12.02 2.954 0.391 0.305     No C860B96F-077E-4B02-A9F9-B55670FD477B 270.04 90.00 W
480A21AF-85AE-4059-B848-33FD5F3A5720 WINDOW WINDOW_CONSTRUCTION_1 26.05 0.00 0.00 26.05 26.05 2.954 0.391 0.305     No 480A21AF-85AE-4059-B848-33FD5F3A5720 180.13 90.00 S
DB1D1E20-BE98-49D4-9E40-1940144BF615 WINDOW WINDOW_CONSTRUCTION_1 0.80 0.00 0.00 0.80 0.80 2.954 0.391 0.305     No DB1D1E20-BE98-49D4-9E40-1940144BF615 90.22 90.00 E
8FC429BC-81D9-449A-80A9-38F77B3E66DD WINDOW WINDOW_CONSTRUCTION_1 21.37 0.00 0.00 21.37 21.37 2.954 0.391 0.305     No 8FC429BC-81D9-449A-80A9-38F77B3E66DD 359.45 90.00 N
759D0D84-9F31-46A9-AB0C-A80AF93CD9F9 WINDOW WINDOW_CONSTRUCTION_1 0.95 0.00 0.00 0.95 0.95 2.954 0.391 0.305     No 759D0D84-9F31-46A9-AB0C-A80AF93CD9F9 0.34 90.00 N
2FB34A99-C1EA-45CB-A3BE-D36736D9F6D4 WINDOW WINDOW_CONSTRUCTION_1 11.21 0.00 0.00 11.21 11.21 2.954 0.391 0.305     No 2FB34A99-C1EA-45CB-A3BE-D36736D9F6D4 270.10 90.00 W
5EC4A61B-3773-449F-B181-753456E72C34 WINDOW WINDOW_CONSTRUCTION_1 10.67 0.00 0.00 10.67 10.67 2.954 0.391 0.305     No 5EC4A61B-3773-449F-B181-753456E72C34 89.40 90.00 E
D9F477EB-A2BB-45DC-80C6-F24D09A96A5C WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No D9F477EB-A2BB-45DC-80C6-F24D09A96A5C 90.32 90.00 E
12B9DB48-E074-4E87-8478-9A8221BFECE1 WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No 12B9DB48-E074-4E87-8478-9A8221BFECE1 269.70 90.00 W
D15932BE-B61F-4D05-8F3D-A538ADA1C1B9 WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No D15932BE-B61F-4D05-8F3D-A538ADA1C1B9 89.40 90.00 E
D7BFAC7E-FFE4-43E5-A664-66123D42D5E0 WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No D7BFAC7E-FFE4-43E5-A664-66123D42D5E0 270.10 90.00 W
88E8F7FF-619E-4595-81EB-D5BAD7867696 WINDOW WINDOW_CONSTRUCTION_1 11.17 0.00 0.00 11.17 11.17 2.954 0.391 0.305     No 88E8F7FF-619E-4595-81EB-D5BAD7867696 89.40 90.00 E
28CE80FE-FE76-466F-A7EB-88A00D656F05 WINDOW WINDOW_CONSTRUCTION_1 11.21 0.00 0.00 11.21 11.21 2.954 0.391 0.305     No 28CE80FE-FE76-466F-A7EB-88A00D656F05 270.10 90.00 W
F5F1247A-88BE-4F06-B629-4C3613F82D51 WINDOW WINDOW_CONSTRUCTION_1 22.18 0.00 0.00 22.18 22.18 2.954 0.391 0.305     No F5F1247A-88BE-4F06-B629-4C3613F82D51 180.04 90.00 S
B8CB1843-0410-4673-BFD4-5DC3C73F2BDD WINDOW WINDOW_CONSTRUCTION_1 0.78 0.00 0.00 0.78 0.78 2.954 0.391 0.305     No B8CB1843-0410-4673-BFD4-5DC3C73F2BDD 179.52 90.00 S
23571505-EC9B-43AD-BFCA-E0997E7A40A6 WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No 23571505-EC9B-43AD-BFCA-E0997E7A40A6 89.40 90.00 E
ED2B8CED-C770-4499-B4D2-1F89BA80E037 WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No ED2B8CED-C770-4499-B4D2-1F89BA80E037 270.10 90.00 W
39CD3473-FBC3-431F-B595-088111688FF0 WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No 39CD3473-FBC3-431F-B595-088111688FF0 89.40 90.00 E
E3C38143-FDEB-4CAD-BFDE-4855A94C5FFE WINDOW WINDOW_CONSTRUCTION_1 10.34 0.00 0.00 10.34 10.34 2.954 0.391 0.305     No E3C38143-FDEB-4CAD-BFDE-4855A94C5FFE 270.10 90.00 W
Total or Average           1128.02 2.954 0.391 0.305              
North Total or Average           277.84 2.954 0.391 0.305              
Non-North Total or Average           850.18 2.954 0.391 0.305              


Interior Fenestration

Construction Area of One Opening [m2] Area of Openings [m2] Glass U-Factor [W/m2-K] Glass SHGC Glass Visible Transmittance Parent Surface
Total or Average     0.00 - - -  


Exterior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          


Interior Door

Construction U-Factor with Film [W/m2-K] U-Factor no Film [W/m2-K] Gross Area [m2] Parent Surface
None          



Table of Contents

Report: Lighting Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Interior Lighting

Zone Lighting Power Density [W/m2] Zone Area [m2] Total Power [W] End Use Subcategory Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Return Air Fraction Conditioned (Y/N) Consumption [kWh]
173347_LIGHTS 173347 16.5060 88.46 1460.14 ELECTRIC EQUIPMENT#173347#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 2984.42
173348_LIGHTS 173348 16.5060 94.56 1560.75 ELECTRIC EQUIPMENT#173348#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3190.05
175012_LIGHTS 175012 27.5100 2308.92 63518.52 ELECTRIC EQUIPMENT#175012#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 129827.20
176261_LIGHTS 176261 16.5060 92.64 1529.05 ELECTRIC EQUIPMENT#176261#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3125.26
176296_LIGHTS 176296 16.5060 96.97 1600.56 ELECTRIC EQUIPMENT#176296#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3271.43
177698_LIGHTS 177698 16.5060 96.59 1594.39 ELECTRIC EQUIPMENT#177698#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3258.81
178164_LIGHTS 178164 16.5060 88.02 1452.93 ELECTRIC EQUIPMENT#178164#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 2969.69
181359_LIGHTS 181359 16.5060 89.11 1470.78 ELECTRIC EQUIPMENT#181359#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3006.17
181706_LIGHTS 181706 16.5060 97.60 1611.01 ELECTRIC EQUIPMENT#181706#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3292.79
183144_LIGHTS 183144 16.5060 89.61 1479.03 ELECTRIC EQUIPMENT#183144#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 3023.02
183243_LIGHTS 183243 16.5060 88.61 1462.52 ELECTRIC EQUIPMENT#183243#GeneralLights LIGHTING SCHEDULES 100-MULTI-UNIT RESIDENTIAL BUILDING 39.20 63.00 39.20 0.0000 Y 2989.28
Interior Lighting Total   24.3694 3231.08 78739.67               160938.11


Daylighting

Zone Control Name Daylighting Method Control Type Fraction Controlled Lighting Installed in Zone [W] Lighting Controlled [W]
None              


Exterior Lighting

Total Watts Astronomical Clock/Schedule Schedule Name Scheduled Hours/Week [hr] Hours/Week > 1% [hr] Full Load Hours/Week [hr] Consumption [kWh]
Exterior Lighting Total 0.00           0.00



Table of Contents

Report: Equipment Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Central Plant

Type Nominal Capacity [W] Nominal Efficiency [W/W] IPLV in SI Units [W/W] IPLV in IP Units [Btu/W-h]
None          


Cooling Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Sensible Capacity [W] Nominal Latent Capacity [W] Nominal Sensible Heat Ratio Nominal Efficiency [W/W] Nominal Coil UA Value [W/C] Nominal Coil Surface Area [m2]
None                  


DX Cooling Coils

DX Cooling Coil Type Standard Rated Net Cooling Capacity [W] Standard Rated Net COP [W/W] EER [Btu/W-h] SEER User [Btu/W-h] SEER Standard [Btu/W-h] IEER [Btu/W-h]
None              


DX Cooling Coil ASHRAE 127 Standard Ratings Report

DX Cooling Coil Type Rated Net Cooling Capacity Test A [W] Rated Electric Power Test A [W] Rated Net Cooling Capacity Test B [W] Rated Electric Power Test B [W] Rated Net Cooling Capacity Test C [W] Rated Electric Power Test C [W] Rated Net Cooling Capacity Test D [W] Rated Electric Power Test D [W]
None                  


DX Heating Coils

DX Heating Coil Type High Temperature Heating (net) Rating Capacity [W] Low Temperature Heating (net) Rating Capacity [W] HSPF [Btu/W-h] Region Number
None          


Heating Coils

Type Design Coil Load [W] Nominal Total Capacity [W] Nominal Efficiency [W/W]
None        


Fans

Type Total Efficiency [W/W] Delta Pressure [pa] Max Air Flow Rate [m3/s] Rated Electricity Rate [W] Rated Power Per Max Air Flow Rate [W-s/m3] Motor Heat In Air Fraction Fan Energy Index End Use Subcategory Design Day Name for Fan Sizing Peak Date/Time for Fan Sizing Peak
None                      


Pumps

Type Control Head [pa] Water Flow [m3/s] Electricity Rate [W] Power Per Water Flow Rate [W-s/m3] Motor Efficiency [W/W] End Use Subcategory
None                


Service Water Heating

Type Storage Volume [m3] Input [W] Thermal Efficiency [W/W] Recovery Efficiency [W/W] Energy Factor
None            



Table of Contents

Report: HVAC Sizing Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Zone Sensible Cooling

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
None                            
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

Zone Sensible Heating

Calculated Design Load [W] User Design Load [W] User Design Load per Area [W/m2] Calculated Design Air Flow [m3/s] User Design Air Flow [m3/s] Design Day Name Date/Time Of Peak {TIMESTAMP} Thermostat Setpoint Temperature at Peak Load [C] Indoor Temperature at Peak Load [C] Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Outdoor Temperature at Peak Load [C] Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] Minimum Outdoor Air Flow Rate [m3/s] Heat Gain Rate from DOAS [W]
None                            
The Design Load is the zone sensible load only. It does not include any system effects or ventilation loads.

System Design Air Flow Rates

Calculated cooling [m3/s] User cooling [m3/s] Calculated heating [m3/s] User heating [m3/s] Adjusted cooling [m3/s] Adjusted heating [m3/s] Adjusted main [m3/s] Calculated Heating Air Flow Ratio [] User Heating Air Flow Ratio []
None                  


Plant Loop Coincident Design Fluid Flow Rate Adjustments

Previous Design Volume Flow Rate [m3/s] Algorithm Volume Flow Rate [m3/s] Coincident Design Volume Flow Rate [m3/s] Coincident Size Adjusted Peak Sizing Period Name Peak Day into Period {TIMESTAMP}[day] Peak Hour Of Day {TIMESTAMP}[hr] Peak Step Start Minute {TIMESTAMP}[min]
None                


Coil Sizing Summary

Coil Type HVAC Type HVAC Name Coil Final Gross Total Capacity [W] Coil Final Gross Sensible Capacity [W] Coil Final Reference Air Volume Flow Rate [m3/s] Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] Coil U-value Times Area Value [W/K] Design Day Name at Sensible Ideal Loads Peak Date/Time at Sensible Ideal Loads Peak Design Day Name at Air Flow Ideal Loads Peak Date/Time at Air Flow Ideal Loads Peak Coil Total Capacity at Ideal Loads Peak [W] Coil Sensible Capacity at Ideal Loads Peak [W] Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] Coil Entering Air Drybulb at Ideal Loads Peak [C] Coil Entering Air Wetbulb at Ideal Loads Peak [C] Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Coil Leaving Air Drybulb at Ideal Loads Peak [C] Coil Leaving Air Wetbulb at Ideal Loads Peak [C] Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Drybulb at Ideal Loads Peak [C] Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Outdoor Air Wetbulb at Ideal Loads Peak [C] Outdoor Air Flow Percentage at Ideal Loads Peak [%] Zone Air Drybulb at Ideal Loads Peak [C] Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] Zone Air Relative Humidity at Ideal Loads Peak [%] Zone Sensible Heat Gain at Ideal Loads Peak [W] Zone Latent Heat Gain at Ideal Loads Peak [W] Coil Total Capacity at Rating Conditions [W] Coil Sensible Capacity at Rating Conditions [W]
None                                                                



Table of Contents

Report: System Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Economizer

High Limit Shutoff Control Minimum Outdoor Air [m3/s] Maximum Outdoor Air [m3/s] Return Air Temp Limit Return Air Enthalpy Limit Outdoor Air Temperature Limit [C] Outdoor Air Enthalpy Limit [C]
None              


Demand Controlled Ventilation using Controller:MechanicalVentilation

Controller:MechanicalVentilation Name Outdoor Air Per Person [m3/s-person] Outdoor Air Per Area [m3/s-m2] Outdoor Air Per Zone [m3/s] Outdoor Air ACH [ach] Outdoor Air Method Outdoor Air Schedule Name Air Distribution Effectiveness in Cooling Mode Air Distribution Effectiveness in Heating Mode Air Distribution Effectiveness Schedule Name
None                    


Time Not Comfortable Based on Simple ASHRAE 55-2004

Winter Clothes [hr] Summer Clothes [hr] Summer or Winter Clothes [hr]
173347 5664.25 6753.25 4241.25
173348 6451.00 7023.25 5122.25
175012 6466.25 6711.25 4718.25
176261 6251.25 6581.25 4560.25
176296 6649.50 6729.75 5002.75
177698 6475.75 6905.00 5037.25
178164 5639.00 6757.50 4221.75
181359 5635.75 6738.50 4203.50
181706 6533.00 6729.75 4916.50
183144 5687.00 6666.50 4175.00
183243 5653.25 6756.50 4234.50
Facility 7305.50 7213.50 5440.25
Aggregated over the RunPeriods for Weather

Time Setpoint Not Met

During Heating [hr] During Cooling [hr] During Occupied Heating [hr] During Occupied Cooling [hr]
173347 0.00 0.00 0.00 0.00
173348 0.00 0.00 0.00 0.00
175012 0.00 0.00 0.00 0.00
176261 0.00 0.00 0.00 0.00
176296 0.00 0.00 0.00 0.00
177698 0.00 0.00 0.00 0.00
178164 0.00 0.00 0.00 0.00
181359 0.00 0.00 0.00 0.00
181706 0.00 0.00 0.00 0.00
183144 0.00 0.00 0.00 0.00
183243 0.00 0.00 0.00 0.00
Facility 0.00 0.00 0.00 0.00
Aggregated over the RunPeriods for Weather


Table of Contents

Report: Outdoor Air Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Average Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
173347 7.18 10.62 796.15 0.000 0.000 0.000 0.387
173348 7.68 11.35 851.01 0.000 0.000 0.000 0.387
175012 312.45 461.95 34633.86 0.000 0.000 0.000 0.388
176261 7.52 11.12 926.36 0.000 0.000 0.000 0.349
176296 7.87 11.64 969.68 0.000 0.000 0.000 0.349
177698 7.84 11.60 869.35 0.000 0.000 0.000 0.387
178164 7.15 10.57 792.22 0.000 0.000 0.000 0.387
181359 7.23 10.70 801.95 0.000 0.000 0.000 0.387
181706 7.92 11.72 878.41 0.000 0.000 0.000 0.387
183144 7.28 10.76 806.45 0.000 0.000 0.000 0.387
183243 7.19 10.64 797.45 0.000 0.000 0.000 0.387
Values shown for a single zone without multipliers

Minimum Outdoor Air During Occupied Hours

Average Number of Occupants Nominal Number of Occupants Zone Volume [m3] Mechanical Ventilation [ach] Infiltration [ach] AFN Infiltration [ach] Simple Ventilation [ach]
173347 7.18 10.62 796.15 0.000 0.000 0.000 0.007
173348 7.68 11.35 851.01 0.000 0.000 0.000 0.007
175012 312.45 461.95 34633.86 0.000 0.000 0.000 0.007
176261 7.52 11.12 926.36 0.000 0.000 0.000 0.006
176296 7.87 11.64 969.68 0.000 0.000 0.000 0.006
177698 7.84 11.60 869.35 0.000 0.000 0.000 0.007
178164 7.15 10.57 792.22 0.000 0.000 0.000 0.007
181359 7.23 10.70 801.95 0.000 0.000 0.000 0.007
181706 7.92 11.72 878.41 0.000 0.000 0.000 0.007
183144 7.28 10.76 806.45 0.000 0.000 0.000 0.007
183243 7.19 10.64 797.45 0.000 0.000 0.000 0.007
Values shown for a single zone without multipliers


Table of Contents

Report: Object Count Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Surfaces by Class

Total Outdoors
Wall 67 53
Floor 11 11
Roof 11 11
Internal Mass 0 0
Building Detached Shading 0 0
Fixed Detached Shading 0 0
Window 53 53
Door 0 0
Glass Door 0 0
Shading 0 0
Overhang 0 0
Fin 0 0
Tubular Daylighting Device Dome 0 0
Tubular Daylighting Device Diffuser 0 0


HVAC

Count
HVAC Air Loops 0
Conditioned Zones 11
Unconditioned Zones 0
Supply Plenums 0
Return Plenums 0


Input Fields

Count
IDF Objects 315
Defaulted Fields 16
Fields with Defaults 1362
Autosized Fields 0
Autosizable Fields 44
Autocalculated Fields 317
Autocalculatable Fields 328



Table of Contents

Report: Sensible Heat Gain Summary

For: Entire Facility

Timestamp: 2023-12-28 13:46:25

Annual Building Sensible Heat Gain Components

HVAC Zone Eq & Other Sensible Air Heating [kWh] HVAC Zone Eq & Other Sensible Air Cooling [kWh] HVAC Terminal Unit Sensible Air Heating [kWh] HVAC Terminal Unit Sensible Air Cooling [kWh] HVAC Input Heated Surface Heating [kWh] HVAC Input Cooled Surface Cooling [kWh] People Sensible Heat Addition [kWh] Lights Sensible Heat Addition [kWh] Equipment Sensible Heat Addition [kWh] Window Heat Addition [kWh] Interzone Air Transfer Heat Addition [kWh] Infiltration Heat Addition [kWh] Opaque Surface Conduction and Other Heat Addition [kWh] Equipment Sensible Heat Removal [kWh] Window Heat Removal [kWh] Interzone Air Transfer Heat Removal [kWh] Infiltration Heat Removal [kWh] Opaque Surface Conduction and Other Heat Removal [kWh]
173347 19119.173 -4267.85 0.000 0.000 0.000 0.000 5307.659 2984.532 5135.721 2753.614 0.000 91.790 0.000 0.000 -5125.08 0.000 -14619.72 -11379.84
173348 30928.922 -4704.88 0.000 0.000 0.000 0.000 5726.987 3190.166 5489.572 3629.142 0.000 98.115 0.000 0.000 -10756.37 0.000 -15493.54 -18108.12
175012 636966.354 -159747.82 0.000 0.000 0.000 0.000 230799.686 129831.959 223412.138 111408.684 0.000 3959.009 0.000 0.000 -163874.95 0.000 -637254.51 -375500.56
176261 27807.673 -7458.00 0.000 0.000 0.000 0.000 5594.960 3125.375 5378.080 9720.278 0.000 95.985 0.000 0.000 -10801.90 0.000 -15269.80 -18192.65
176296 38663.034 -8362.88 0.000 0.000 0.000 0.000 5885.326 3271.548 5629.613 11545.527 0.000 100.474 0.000 0.000 -15726.58 0.000 -15905.03 -25101.03
177698 30848.064 -5199.82 0.000 0.000 0.000 0.000 5845.125 3258.933 5607.905 4291.381 0.000 100.230 0.000 0.000 -10715.25 0.000 -15846.87 -18189.70
178164 18933.250 -4237.97 0.000 0.000 0.000 0.000 5281.620 2969.800 5110.370 2778.465 0.000 91.337 0.000 0.000 -5048.14 0.000 -14547.42 -11331.32
181359 19061.231 -4317.49 0.000 0.000 0.000 0.000 5344.793 3006.279 5173.143 2865.239 0.000 92.459 0.000 0.000 -5095.24 0.000 -14731.03 -11399.38
181706 30101.925 -6864.95 0.000 0.000 0.000 0.000 5896.622 3292.907 5666.366 6250.155 0.000 101.275 0.000 0.000 -10745.07 0.000 -16049.71 -17649.52
183144 19069.445 -4715.58 0.000 0.000 0.000 0.000 5370.213 3023.131 5202.140 3258.115 0.000 92.978 0.000 0.000 -5114.86 0.000 -14825.95 -11359.64
183243 19116.684 -4262.05 0.000 0.000 0.000 0.000 5316.318 2989.389 5144.079 2755.948 0.000 91.940 0.000 0.000 -5115.79 0.000 -14643.45 -11393.07
Total Facility 890615.755 -214139.28 0.000 0.000 0.000 0.000 286369.309 160944.020 276949.125 161256.548 0.000 4915.592 0.000 0.000 -248119.24 0.000 -789187.02 -529604.81


Peak Cooling Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
173347 15-AUG-14:45 0.00 -6165.62 0.00 0.00 0.00 0.00 232.98 0.00 530.96 2923.88 0.00 678.25 1799.55 0.00 -0.00 0.00 0.00 0.00
173348 15-AUG-14:45 0.00 -7518.29 0.00 0.00 0.00 0.00 249.03 0.00 567.54 3973.84 0.00 724.98 2002.89 0.00 -0.00 0.00 0.00 0.00
175012 20-JUL-19:15 0.00 -201080.30 0.00 0.00 0.00 0.00 30404.80 57166.67 51969.70 18715.80 0.00 23479.60 19343.73 0.00 -0.00 0.00 0.00 0.00
176261 15-AUG-14:00 0.00 -11436.74 0.00 0.00 0.00 0.00 243.97 0.00 556.02 7284.52 0.00 710.43 2641.80 0.00 -0.00 0.00 0.00 0.00
176296 15-AUG-14:15 0.00 -12943.36 0.00 0.00 0.00 0.00 255.38 0.00 582.02 8574.62 0.00 743.49 2787.84 0.00 -0.00 0.00 0.00 0.00
177698 15-AUG-14:45 0.00 -8164.01 0.00 0.00 0.00 0.00 254.40 0.00 579.78 4497.03 0.00 740.61 2092.19 0.00 -0.00 0.00 0.00 0.00
178164 15-AUG-14:45 0.00 -6143.17 0.00 0.00 0.00 0.00 231.83 0.00 528.34 2922.73 0.00 674.90 1785.37 0.00 -0.00 0.00 0.00 0.00
181359 15-AUG-14:45 0.00 -6173.87 0.00 0.00 0.00 0.00 234.68 0.00 534.83 2914.56 0.00 683.19 1806.61 0.00 -0.00 0.00 0.00 0.00
181706 15-AUG-14:00 0.00 -10363.29 0.00 0.00 0.00 0.00 257.05 0.00 585.82 6369.84 0.00 748.85 2401.73 0.00 -0.00 0.00 0.00 0.00
183144 15-AUG-15:45 0.00 -6696.94 0.00 0.00 0.00 0.00 235.99 0.00 537.83 3269.45 0.00 665.73 1987.95 0.00 -0.00 0.00 0.00 0.00
183243 15-AUG-14:45 0.00 -6162.86 0.00 0.00 0.00 0.00 233.36 0.00 531.82 2919.25 0.00 679.36 1799.07 0.00 -0.00 0.00 0.00 0.00
Total Facility 15-AUG-14:45 0.00 -269949.00 0.00 0.00 0.00 0.00 12563.60 0.00 28632.61 127239.89 0.00 36496.57 65016.33 0.00 0.00 0.00 0.00 0.00


Peak Heating Sensible Heat Gain Components

Time of Peak {TIMESTAMP} HVAC Zone Eq & Other Sensible Air Heating [W] HVAC Zone Eq & Other Sensible Air Cooling [W] HVAC Terminal Unit Sensible Air Heating [W] HVAC Terminal Unit Sensible Air Cooling [W] HVAC Input Heated Surface Heating [W] HVAC Input Cooled Surface Cooling [W] People Sensible Heat Addition [W] Lights Sensible Heat Addition [W] Equipment Sensible Heat Addition [W] Window Heat Addition [W] Interzone Air Transfer Heat Addition [W] Infiltration Heat Addition [W] Opaque Surface Conduction and Other Heat Addition [W] Equipment Sensible Heat Removal [W] Window Heat Removal [W] Interzone Air Transfer Heat Removal [W] Infiltration Heat Removal [W] Opaque Surface Conduction and Other Heat Removal [W]
173347 04-JAN-07:02 32807.26 0.00 0.00 0.00 0.00 0.00 753.18 730.07 1061.92 0.00 0.00 0.00 0.00 0.00 -1379.99 0.00 -3301.40 -30671.05
173348 04-FEB-08:02 38683.72 0.00 0.00 0.00 0.00 0.00 420.75 780.37 1135.09 0.00 0.00 0.00 0.00 0.00 -3404.53 0.00 -5575.71 -32039.69
175012 23-FEB-07:02 1365114.16 0.00 0.00 0.00 0.00 0.00 32764.76 31759.26 46195.29 0.00 0.00 0.00 0.00 0.00 -41598.56 0.00 -174909.17 -1259325.73
176261 12-JAN-07:03 41660.75 0.00 0.00 0.00 0.00 0.00 788.73 764.52 1112.03 0.00 0.00 0.00 0.00 0.00 -4444.88 0.00 -5053.36 -34827.79
176296 12-JAN-07:03 47366.34 0.00 0.00 0.00 0.00 0.00 825.62 800.28 1164.04 0.00 0.00 0.00 0.00 0.00 -6549.67 0.00 -5288.20 -38318.43
177698 04-FEB-08:02 39352.65 0.00 0.00 0.00 0.00 0.00 429.82 797.19 1159.56 0.00 0.00 0.00 0.00 0.00 -3293.55 0.00 -5695.96 -32749.71
178164 04-JAN-07:02 32658.81 0.00 0.00 0.00 0.00 0.00 749.47 726.47 1056.68 0.00 0.00 0.00 0.00 0.00 -1378.57 0.00 -3285.10 -30527.76
181359 04-JAN-07:02 33023.84 0.00 0.00 0.00 0.00 0.00 758.67 735.39 1069.66 0.00 0.00 0.00 0.00 0.00 -1380.00 0.00 -3325.47 -30882.09
181706 04-FEB-08:02 39600.90 0.00 0.00 0.00 0.00 0.00 434.30 805.51 1171.64 0.00 0.00 0.00 0.00 0.00 -3131.42 0.00 -5755.42 -33125.51
183144 04-JAN-07:02 33194.46 0.00 0.00 0.00 0.00 0.00 762.93 739.51 1075.65 0.00 0.00 0.00 0.00 0.00 -1382.61 0.00 -3344.11 -31045.84
183243 04-JAN-07:02 32855.23 0.00 0.00 0.00 0.00 0.00 754.41 731.26 1063.65 0.00 0.00 0.00 0.00 0.00 -1379.56 0.00 -3306.78 -30718.21
Total Facility 23-FEB-07:02 1728481.41 0.00 0.00 0.00 0.00 0.00 40616.28 39369.84 57265.22 217.50 0.00 0.00 0.00 0.00 -49037.55 0.00 -216792.07 -1600120.62