\section{Current Status}
\begin{table}[htbp]
\caption{City Buildings Energy Demands}
\centering
\begin{tabularx}{\textwidth}{|X|X|X|X|X|X|X|}
\hline
Building Name & Year of Construction & function & Yearly Heating Demand (MWh) & Yearly Cooling Demand (MWh) & Yearly DHW Demand (MWh) & Yearly Electricity Demand (MWh) \\
\hline
175785 & 1986 & residential & 43.10 & 14.78 & 34.15 & 14.31 \\
\hline
176293 & 1986 & residential & 38.65 & 9.54 & 26.99 & 11.31 \\
\hline
182393 & 1986 & residential & 32.38 & 8.14 & 14.56 & 6.10 \\
\hline
\end{tabularx}
\end{table}
\begin{table}[htbp]
\caption{Energy Intensity Information}
\centering
\begin{tabularx}{\textwidth}{|X|X|X|X|X|}
\hline
Building Name & Total Floor Area m2 & Heating Demand Intensity kWh/m2 & Cooling Demand Intensity kWh/m2 & Electricity Intensity kWh/m2 \\
\hline
175785 & 467.72 & 92.15 & 31.60 & 30.60 \\
\hline
176293 & 369.69 & 104.55 & 25.81 & 30.60 \\
\hline
182393 & 199.37 & 162.41 & 40.82 & 30.60 \\
\hline
\end{tabularx}
\end{table}
\begin{figure}[htbp]
\centering
\includegraphics[width=0.8\textwidth]{hvac_demand_chart.jpg}
\caption{Yearly HVAC Demands}
\end{figure}
\begin{figure}[htbp]
\centering
\includegraphics[width=0.8\textwidth]{dhw_demand_chart.jpg}
\caption{Yearly DHW Demands}
\end{figure}
\begin{figure}[htbp]
\centering
\includegraphics[width=0.8\textwidth]{electricity_demand_chart.jpg}
\caption{Yearly Electricity Demands}
\end{figure}
\begin{table}[htbp]
\caption{175785 Information}
\centering
\begin{tabularx}{\textwidth}{|p{1.5cm}|X|}
\hline
Maximum Monthly HVAC Demands & \includegraphics[width=1\linewidth]{175785_monthly_maximum_hvac_loads.jpg} \\
\hline
Load Duration Curve & \includegraphics[width=1\linewidth]{175785_load_duration_curve.jpg} \\
\hline
\end{tabularx}
\end{table}
\begin{table}[htbp]
\caption{Building 175785 Energy System Characteristics}
\centering
\begin{tabularx}{\textwidth}{|X|X|X|}
\hline
Detail & Existing System & Proposed System \\
\hline
Energy System Archetype & system 1 gas & - \\
\hline
System Schematic & - & - \\
\hline
Heating System & Unitary air conditioner with baseboard heater fuel fired boiler & - \\
\hline
Cooling System & Unitary air conditioner air cooled DX with external condenser & - \\
\hline
DHW System & Unitary air conditioner with baseboard heater fuel fired boiler & - \\
\hline
Electricity & Grid & - \\
\hline
Fuel(s) & ['Gas', 'Electricity'] & - \\
\hline
HVAC Energy Consumption (MWh) & 55.28 & - \\
\hline
DHW Energy Consumption (MWH) & 40.18 & - \\
\hline
Yearly Operational Cost (CAD) & - & - \\
\hline
Life Cycle Cost (CAD) & - & - \\
\hline
\end{tabularx}
\end{table}
\begin{figure}[htbp]
\centering
\includegraphics[width=0.8\textwidth]{175785_energy_consumption_breakdown.png}
\caption{Building 175785 Consumption by source and sector breakdown}
\end{figure}
\begin{table}[htbp]
\caption{176293 Information}
\centering
\begin{tabularx}{\textwidth}{|p{1.5cm}|X|}
\hline
Maximum Monthly HVAC Demands & \includegraphics[width=1\linewidth]{176293_monthly_maximum_hvac_loads.jpg} \\
\hline
Load Duration Curve & \includegraphics[width=1\linewidth]{176293_load_duration_curve.jpg} \\
\hline
\end{tabularx}
\end{table}
\begin{table}[htbp]
\caption{Building 176293 Energy System Characteristics}
\centering
\begin{tabularx}{\textwidth}{|X|X|X|}
\hline
Detail & Existing System & Proposed System \\
\hline
Energy System Archetype & system 1 gas & - \\
\hline
System Schematic & - & - \\
\hline
Heating System & Unitary air conditioner with baseboard heater fuel fired boiler & - \\
\hline
Cooling System & Unitary air conditioner air cooled DX with external condenser & - \\
\hline
DHW System & Unitary air conditioner with baseboard heater fuel fired boiler & - \\
\hline
Electricity & Grid & - \\
\hline
Fuel(s) & ['Gas', 'Electricity'] & - \\
\hline
HVAC Energy Consumption (MWh) & 48.43 & - \\
\hline
DHW Energy Consumption (MWH) & 31.75 & - \\
\hline
Yearly Operational Cost (CAD) & - & - \\
\hline
Life Cycle Cost (CAD) & - & - \\
\hline
\end{tabularx}
\end{table}
\begin{figure}[htbp]
\centering
\includegraphics[width=0.8\textwidth]{176293_energy_consumption_breakdown.png}
\caption{Building 176293 Consumption by source and sector breakdown}
\end{figure}
\begin{table}[htbp]
\caption{182393 Information}
\centering
\begin{tabularx}{\textwidth}{|p{1.5cm}|X|}
\hline
Maximum Monthly HVAC Demands & \includegraphics[width=1\linewidth]{182393_monthly_maximum_hvac_loads.jpg} \\
\hline
Load Duration Curve & \includegraphics[width=1\linewidth]{182393_load_duration_curve.jpg} \\
\hline
\end{tabularx}
\end{table}
\begin{table}[htbp]
\caption{Building 182393 Energy System Characteristics}
\centering
\begin{tabularx}{\textwidth}{|X|X|X|}
\hline
Detail & Existing System & Proposed System \\
\hline
Energy System Archetype & system 8 gas & - \\
\hline
System Schematic & - & - \\
\hline
Heating System & Unitary air conditioner with baseboard heater fuel fired boiler & - \\
\hline
Cooling System & - & - \\
\hline
DHW System & Unitary air conditioner with baseboard heater fuel fired boiler & - \\
\hline
Electricity & Grid & - \\
\hline
Fuel(s) & ['Gas'] & - \\
\hline
HVAC Energy Consumption (MWh) & 38.09 & - \\
\hline
DHW Energy Consumption (MWH) & 17.12 & - \\
\hline
Yearly Operational Cost (CAD) & - & - \\
\hline
Life Cycle Cost (CAD) & - & - \\
\hline
\end{tabularx}
\end{table}