CityBEM-CityLayers-SaeedRay.../hub/data/energy_systems/montreal_custom_systems.xml

487 lines
20 KiB
XML

<catalog lod="1">
<generation_equipments>
<equipment id="1" type="boiler" fuel_type="gas">
<name>Fuel-fired water boiler</name>
<heating_efficiency>0.85</heating_efficiency>
<storage>false</storage>
</equipment>
<equipment id="2" type="boiler" fuel_type="electricity">
<name>Electric water boiler</name>
<heating_efficiency>1</heating_efficiency>
<storage>true</storage>
</equipment>
<equipment id="3" type="furnace" fuel_type="gas">
<name>Fuel-fired furnace and fuel boiler for acs</name>
<heating_efficiency>0.85</heating_efficiency>
<storage>false</storage>
</equipment>
<equipment id="4" type="furnace" fuel_type="electricity">
<name>Electrical furnace and fuel boiler for acs</name>
<heating_efficiency>1</heating_efficiency>
<storage>false</storage>
</equipment>
<equipment id="5" type="cooler" fuel_type="electricity">
<name>Air cooled DX with external condenser</name>
<cooling_efficiency>3.23</cooling_efficiency>
<storage>false</storage>
</equipment>
<equipment id="6" type="electricity generator" fuel_type="renewable">
<name>PV system</name>
<electrical_efficiency>0.22</electrical_efficiency>
<storage>true</storage>
</equipment>
<equipment id="7" type="heat pump" fuel_type="electricity">
<name>Heat Pump</name>
<heating_efficiency>2.79</heating_efficiency>
<cooling_efficiency>3.23</cooling_efficiency>
<storage>false</storage>
</equipment>
</generation_equipments>
<distribution_equipments>
<equipment id="1" type="Water distribution heating with baseboards">
<name>Water distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>1</dissipation_id>
</equipment>
<equipment id="2" type="Water distribution heating with fan-coils">
<name>Water distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="3" type="Water distribution heating with inductors">
<name>Water distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="4" type="Water distribution cooling with fan-coils">
<name>Water distribution cooling</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">4</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="5" type="Central air distribution heating with fan-coils">
<name>Central air distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="6" type="Central air distribution heating with inductors">
<name>Central air distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="7" type="Central air distribution cooling with fan-coils">
<name>Central air distribution cooling</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="8" type="Local air distribution heating with baseboards">
<name>Local air distribution heating</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>1</dissipation_id>
</equipment>
<equipment id="9" type="Local air distribution heating with inductors">
<name>Local air distribution heating</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="10" type="Local air distribution cooling with inductors">
<name>Local air distribution cooling</name>
<distribution_heat_losses units="%">2</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="11" type="Refrigerant distribution with fan-coils">
<name>Refrigerant distribution</name>
<distribution_heat_losses units="%">1</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">1</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="12" type="No distribution with baseboards">
<name>No distribution</name>
<distribution_heat_losses units="%">0</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>1</dissipation_id>
</equipment>
<equipment id="13" type="No distribution with inductors">
<name>No distribution</name>
<distribution_heat_losses units="%">0</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
</distribution_equipments>
<dissipation_equipments>
<equipment id="1" type="baseboards">
<name>Baseboards</name>
<parasitic_consumption units="%">0</parasitic_consumption>
</equipment>
<equipment id="2" type="fan-coils">
<name>fan-coils</name>
<parasitic_consumption units="%">1</parasitic_consumption>
</equipment>
<equipment id="3" type="inductors">
<name>inductors</name>
<parasitic_consumption units="%">0</parasitic_consumption>
</equipment>
</dissipation_equipments>
<systems>
<system id = "1">
<name>Unitary air conditioner with baseboard heater fuel fired boiler</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>1</generation_id>
<distribution_id>1</distribution_id>
</equipments>
</system>
<system id = "16">
<name>Unitary air conditioner with baseboard heater electrical boiler</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>12</distribution_id>
</equipments>
</system>
<system id = "2">
<name>4 pipe fan coils with fuel fired boiler</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>1</generation_id>
<distribution_id>2</distribution_id>
</equipments>
</system>
<system id="3">
<name>4 pipe fan coils with electrical resistance water boiler</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>2</distribution_id>
</equipments>
</system>
<system id="4">
<name>Single zone packaged rooftop unit with fuel-fired furnace and baseboards and fuel boiler for acs</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>3</generation_id>
<distribution_id>8</distribution_id>
g </equipments>
</system>
<system id="5">
<name>Single zone packaged rooftop unit with electrical resistance furnace and baseboards and fuel boiler for acs</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>4</generation_id>
<distribution_id>8</distribution_id>
</equipments>
</system>
<system id="6">
<name>Single zone make-up air unit with baseboard heating with fuel fired boiler</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>1</generation_id>
<distribution_id>1</distribution_id>
</equipments>
</system>
<system id="7">
<name>Single zone make-up air unit with electrical baseboard heating and DHW with resistance</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>13</distribution_id>
</equipments>
</system>
<system id="8">
<name>Multi-zone built-up system with baseboard heater hydronic with fuel fired boiler</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>3</distribution_id>
</equipments>
</system>
<system id="9">
<name>Multi-zone built-up system with electrical baseboard heater and electrical hot water</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>13</distribution_id>
</equipments>
</system>
<system id="10">
<name>Unitary air conditioner air cooled DX with external condenser</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>10</distribution_id>
</equipments>
</system>
<system id="11">
<name>4 pipe fan coils with water cooled, water chiller</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>4</distribution_id>
</equipments>
</system>
<system id="12">
<name>Single zone packaged rooftop unit with air cooled DX</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>10</distribution_id>
</equipments>
</system>
<system id="13">
<name>Single zone make-up air unit with air cooled DX</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>10</distribution_id>
</equipments>
</system>
<system id="14">
<name>Multi-zone built-up system with water cooled, water chiller</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>6</distribution_id>
</equipments>
</system>
<system id="15">
<name>PV system</name>
<demands>
<demand>electricity</demand>
</demands>
<equipments>
<generation_id>6</generation_id>
<distribution_id>9</distribution_id>
</equipments>
</system>
<system id="17">
<name>Multi-zone built-up system with heat pump for heat</name>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>7</generation_id>
<distribution_id>5</distribution_id>
</equipments>
</system>
<system id="18">
<name>Multi-zone built-up system with heat pump for cooling</name>
<demands>
<demand>cooling</demand>
</demands>
<equipments>
<generation_id>7</generation_id>
<distribution_id>7</distribution_id>
</equipments>
</system>
</systems>
<system_clusters>
<system_cluster name="system 1 gas">
<systems>
<system_id>1</system_id>
<system_id>10</system_id>
</systems>
</system_cluster>
<system_cluster name="system 1 gas pv">
<systems>
<system_id>1</system_id>
<system_id>10</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 1 electricity">
<systems>
<system_id>16</system_id>
<system_id>10</system_id>
</systems>
</system_cluster>
<system_cluster name="system 1 electricity pv">
<systems>
<system_id>16</system_id>
<system_id>10</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 2 gas">
<systems>
<system_id>2</system_id>
<system_id>11</system_id>
</systems>
</system_cluster>
<system_cluster name="system 2 gas pv">
<systems>
<system_id>2</system_id>
<system_id>11</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 2 electricity">
<systems>
<system_id>3</system_id>
<system_id>11</system_id>
</systems>
</system_cluster>
<system_cluster name="system 2 electricity pv">
<systems>
<system_id>3</system_id>
<system_id>11</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 3 and 4 gas">
<systems>
<system_id>4</system_id>
<system_id>12</system_id>
</systems>
</system_cluster>
<system_cluster name="system 3 and 4 gas pv">
<systems>
<system_id>4</system_id>
<system_id>12</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 3 and 4 electricity">
<systems>
<system_id>5</system_id>
<system_id>12</system_id>
</systems>
</system_cluster>
<system_cluster name="system 3 and 4 electricity pv">
<systems>
<system_id>5</system_id>
<system_id>12</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 5">
<systems>
<system_id>11</system_id>
</systems>
</system_cluster>
<system_cluster name="system 5 pv">
<systems>
<system_id>11</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 6 gas">
<systems>
<system_id>8</system_id>
<system_id>14</system_id>
</systems>
</system_cluster>
<system_cluster name="system 6 gas pv">
<systems>
<system_id>8</system_id>
<system_id>14</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 6 electricity">
<systems>
<system_id>9</system_id>
<system_id>14</system_id>
</systems>
</system_cluster>
<system_cluster name="system 6 electricity pv">
<systems>
<system_id>9</system_id>
<system_id>14</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 7 electricity pv">
<systems>
<system_id>17</system_id>
<system_id>18</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 8 gas">
<systems>
<system_id>1</system_id>
</systems>
</system_cluster>
<system_cluster name="system 8 gas pv">
<systems>
<system_id>1</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
<system_cluster name="system 8 electricity">
<systems>
<system_id>16</system_id>
</systems>
</system_cluster>
<system_cluster name="system 8 electricity pv">
<systems>
<system_id>16</system_id>
<system_id>15</system_id>
</systems>
</system_cluster>
</system_clusters>
</catalog>