Compare commits

..

294 Commits

Author SHA1 Message Date
7bd7b680b3 Update hub/version.py 2024-12-12 14:14:34 -05:00
Guille
765784135d Correct old ep export and optimize code 2024-12-12 20:09:58 +01:00
08e7f68adf Update hub/version.py 2024-12-07 02:48:32 -05:00
Guille
464abea93a Correct package 2024-12-07 08:46:05 +01:00
7d057ece81 Update hub/version.py 2024-12-04 09:45:28 -05:00
04f24e9d91 Merge pull request 'main' (#79) from main into feature/cerc_idf
Reviewed-on: #79
2024-12-04 02:09:57 -05:00
4da206761a Update hub/version.py 2024-12-04 01:10:53 -05:00
0f6a2a5b8f Update hub/version.py 2024-12-04 00:26:16 -05:00
766eba2cb7 Merge pull request 'Remove usages_percentage in favor of usages' (#78) from fix/remove-usages_percentage into main
Reviewed-on: #78
2024-12-04 00:11:05 -05:00
Connor Brackley
103923b272 Changed sql usage type to JSON 2024-12-03 18:41:54 -05:00
Connor Brackley
a492a9eb0a Remove usages_percentage in favor of usages 2024-12-03 17:28:00 -05:00
5ec1708a2c Update hub/version.py 2024-12-03 00:42:54 -05:00
1bac29118e bug fix in result reading 2024-12-03 06:41:13 +01:00
246e3442a6 Merge branch 'main' into feature/cerc_idf 2024-12-03 05:35:09 +01:00
7831af9144 Update hub/version.py 2024-12-02 14:57:29 -05:00
06532adbb9 bug fix 2024-12-02 20:56:06 +01:00
fba7effd52 bug fix 2024-12-02 20:53:45 +01:00
5ca4a802cd Update hub/version.py 2024-12-02 14:14:28 -05:00
f4598ac946 bug fix 2024-12-02 20:13:56 +01:00
1f3d981ace Merge branch 'main' into feature/cerc_idf 2024-11-30 07:33:26 +01:00
f3454bbb72 bug fix 2024-11-30 07:32:46 +01:00
20b7929519 Update hub/version.py 2024-11-29 00:24:27 -05:00
d6032b06a4 Merge pull request 'fix/multi-useage' (#77) from fix/multi-useage into main
Reviewed-on: #77
2024-11-29 00:23:59 -05:00
Connor Brackley
f0a72919ff Fix typos 2024-11-28 22:30:25 +00:00
faa2c772ba Merge remote-tracking branch 'origin/main' 2024-11-28 22:08:47 +01:00
90353cde16 handle error in wwr 2024-11-28 22:08:34 +01:00
fb10e89248 Update hub/exports/building_energy/idf.py 2024-11-28 15:52:23 -05:00
b9cb69ec05 Try to correct the importer 2024-11-28 21:46:21 +01:00
Connor Brackley
da819ad9d0 Minor bug fixes 2024-11-27 22:56:39 +00:00
Connor Brackley
44e6820ce6 Improve documentation and error handling 2024-11-27 22:06:22 +00:00
Connor Brackley
66dbda5525 Update usage handling in thermal zones 2024-11-27 22:06:03 +00:00
383bcc976f Update hub/version.py 2024-11-27 12:35:23 -05:00
0d44e38985 Merge pull request 'fix: total_installed_capacity attribute added to PvGeneration class, idf modified, redundant palma file removed' (#76) from feature/pv_epw_fix into main
Reviewed-on: #76
2024-11-27 12:32:58 -05:00
f4b4d0551f fix: total_installed_capacity attribute added to PvGeneration class, idf modified, redundant palma file removed 2024-11-27 18:16:40 +01:00
Connor Brackley
e0d1f1f8fb Added multi-usage to tests 2024-11-25 22:53:07 +00:00
Connor Brackley
2c6f602a2e Bug fixes 2024-11-25 22:42:54 +00:00
Vagrant
1449298a25 Update multi-usage methods to work with usage geojson input and parsers 2024-11-24 06:48:35 +00:00
c2a5cc2d5c Correct output names 2024-11-22 06:51:54 +01:00
b9c6594591 Update hub/version.py 2024-11-20 05:16:06 -05:00
76b67b38df Merge pull request 'feature/pv_workflow' (#75) from feature/pv_workflow into main
Reviewed-on: #75
2024-11-20 05:15:26 -05:00
2e7f4f1fe3 fix: montreal_custom systems moved to montreal_future catalogue 2024-11-17 15:29:19 +01:00
ddf10fb2ae feat: catalogues and importers are modified to be able to be implemented with PV workflow 2024-11-15 13:58:11 +01:00
f94ce25394 Partial correction of output names and result imports 2024-11-12 07:04:57 +01:00
8552b7cbd1 Bug fix 2024-11-08 06:58:23 +01:00
14404fbf04 Include oriol's infiltration changes into cerc_idf and remove empty file 2024-11-08 06:41:15 +01:00
c804c5ee6a Merge branch 'main' into feature/cerc_idf 2024-10-29 22:02:08 +01:00
3db3acd3c6 update version number 2024-10-29 22:00:57 +01:00
ddf4631c59 test 2024-10-29 21:52:38 +01:00
15aaf2a337 Merge pull request 'feat: Palma catalogues and importers are added' (#73) from feature/palma into main
Reviewed-on: #73
2024-10-29 16:46:17 -04:00
7ad16ba640 feat: Palma catalogues and importers are added 2024-10-29 11:36:47 +01:00
f42bb64b85 revert 3dd64143ab
revert Merge pull request 'feat: all the catalogues, importers, data and tests of palma are added' (#72) from feature/palma into main

Reviewed-on: #72
2024-10-22 14:27:35 -04:00
3dd64143ab Merge pull request 'feat: all the catalogues, importers, data and tests of palma are added' (#72) from feature/palma into main
Reviewed-on: #72
2024-10-21 17:32:20 -04:00
164ffbf9c8 feat: all the catalogues, importers, data and tests of palma are added 2024-10-21 23:30:10 +02:00
bf4018a649 Update version number 2024-10-20 17:39:54 +02:00
6c7f652390 Merge pull request 'fix: the small bug in test units is resolved, the construction and usage factories can be loaded without any order' (#71) from small_bugs_in_user_tests into main
Reviewed-on: #71
2024-10-20 11:15:40 -04:00
4e46b6bc0d fix: the small bug in test units is resolved, the construction and usage factories can be loaded without any order 2024-10-18 12:28:38 +02:00
4ac9ccda81 Update hub/version.py 2024-10-17 08:05:13 -04:00
df2d7a3054 Geojson class modified for the geojson format Guille suggested 2024-10-17 07:40:13 -04:00
47810737fa geojson, construction and usage importers are all modified for mixed use buildings 2024-10-17 07:40:13 -04:00
99535a979c Update hub/version.py 2024-10-17 00:19:27 -04:00
9986552ec1 Merge remote-tracking branch 'origin/main' 2024-10-17 06:17:48 +02:00
d1719b50ed Merge branch 'infilt_availability_oriol' 2024-10-17 06:15:04 +02:00
6020964899 Validation in progress 2024-10-17 06:13:23 +02:00
841a6136bb Validation in progress 2024-10-15 06:12:11 +02:00
68d2bef9ec Validation in progress 2024-10-15 05:24:33 +02:00
5e01f4eb7f Merge pull request 'Remove build from setup.py and add it to requirements.txt' (#69) from fix/fix-build into main
Reviewed-on: #69
2024-10-03 14:08:37 -04:00
d38150ac2d Remove build from setup.py and add it to requirements.txt 2024-10-03 13:05:56 -05:00
afe5e433ea complete refactor 2024-10-03 15:40:02 +02:00
16b0726db7 correct refactor 2024-10-03 13:56:01 +02:00
b915dbdead Merge branch 'main' into feature/cerc_idf 2024-10-03 13:29:29 +02:00
cd7ac9378e Merge branch 'main' into feature/cerc_idf 2024-10-03 13:16:38 +02:00
5e5129ecd7 Merge pull request 'Add build package to setup.py and remove texttest' (#68) from fix/update-setup.py into main
Reviewed-on: #68
2024-10-02 12:07:55 -04:00
3905f228dc correct unittests 2024-10-02 06:30:43 +02:00
33049441f0 Add build package to setup.py and remove texttest 2024-10-01 14:35:08 -05:00
70dd9f7c6a Merge pull request 'fix: change building names in ep_multiple_buildings.py to upper case' (#66) from fix/ep-result-factory-naming-bug into main
Reviewed-on: #66
2024-10-01 10:15:40 -04:00
0ce392ea06 fix: change building names in ep_multiple_buildings.py to upper case 2024-10-01 09:43:57 -04:00
ogavalda
4b6a942324 Small change. test 2024-09-30 15:58:21 -04:00
2495046c44 correct typo 2024-09-30 19:46:07 +02:00
0157f47bdc Refactor completed 2024-09-30 16:26:19 +02:00
8687b1257d Merge branch 'main' into feature/cerc_idf 2024-09-30 15:17:31 +02:00
4738de0d8c Merge branch 'infilt_availability_oriol' 2024-09-30 15:17:05 +02:00
78aa84c338 Partial refactor 2024-09-30 15:15:57 +02:00
dc98b634e8 add weather file to the EnergyBuildingsExportsFactory 2024-09-27 14:33:51 +02:00
e220bf2c0d Merge remote-tracking branch 'origin/main' 2024-09-23 18:26:33 +02:00
a45cf02b28 Update hub/version.py 2024-09-23 11:57:33 -04:00
ef62e2531f add weather file to the EnergyBuildingsExportsFactory 2024-09-23 17:56:58 +02:00
27514d4d77 cerc idf implementation refactoring and added systems 2024-09-23 17:52:52 +02:00
5e384c8185 cerc idf implementation refactoring and added systems 2024-09-18 06:56:04 +02:00
ogavalda
cd34435a9f Including air temperature output 2024-09-16 15:49:18 -04:00
ogavalda
15b96fe154 Changing the full structure to incorporate a second way of entering infiltration (infiltration per outdoor area) 2024-09-16 15:41:27 -04:00
62c9a5aab7 cerc idf implementation 2024-09-16 17:34:43 +02:00
ogavalda
54a6e6b2db Adding infiltration per m2 2024-09-15 10:22:07 -04:00
ogavalda
a7375f0b53 Adding infiltration per m2 2024-09-15 10:15:41 -04:00
ogavalda
725746fbcb Changes in infiltration profiles and the source of values for infiltration 2024-09-15 09:44:07 -04:00
cc2ee61ada inputs completed 2024-09-13 06:55:12 +02:00
5401064905 cerc_idf basic implementation 2024-09-12 06:57:15 +02:00
ec320a2e1c Merge pull request 'fix: small bugs in the irradiance units were fixed.' (#65) from irradiance_unit_fixing into main
Reviewed-on: #65
2024-09-09 13:27:05 -04:00
8a68118503 fix: small bugs in the irradiance units were fixed. 2024-09-09 11:11:33 -04:00
a3ec3c7e19 Merge pull request 'Add version number to numpy' (#64) from fix/downgrade-numpy into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/64

Hi Connor, I have accepted the change, but some additional review will be needed, it creates a hard dependency from a specific version of numpy with almost sure will create issues with other libraries, will be nice if you could keep an eye on the issue resolution from sqlalchemy
2024-09-02 12:35:30 -04:00
connor
ace666553a Add version number to numpy 2024-08-30 18:01:26 -04:00
c4636c2c3c Merge remote-tracking branch 'origin/main' 2024-07-25 18:11:10 +02:00
4a01ac51d8 Remove the building from the targets if needed 2024-07-25 18:10:51 +02:00
ee846a6225 Update hub/version.py 2024-07-16 01:25:01 -04:00
a4f3b48617 Merge remote-tracking branch 'origin/main' 2024-07-16 07:24:41 +02:00
abc3fc48dd Add type to constructions to avoid collisions in constructions names 2024-07-16 07:24:22 +02:00
db371aecf3 Update hub/version.py 2024-07-10 05:57:01 -04:00
998df80b63 Correct shading object selection and idd file 2024-07-10 11:55:13 +02:00
446c7fa4ce Correct correct shadding object selection and idd file 2024-07-10 07:39:53 +02:00
3c5f1b7357 Update hub/version.py 2024-07-04 03:55:45 -04:00
6d2bb98470 Correct bug in shadding object creation when no archetype available 2024-07-04 09:53:45 +02:00
26b2af1e2b Merge remote-tracking branch 'origin/modifying_energy_system_catalogs_and_importers' into modifying_energy_system_catalogs_and_importers 2024-07-04 08:17:59 +02:00
dc3372ff5e fix: final changes to catalogue, importer, and parameter importer 2024-07-03 10:35:31 -04:00
a81c0cfee3 Correct bug in shadding object creation when no archetype available 2024-07-01 18:48:37 +02:00
1279dffff8 fix: small issue in the city creator was resolved 2024-07-01 12:16:26 -04:00
1cc7b2cb8c IDFL Add objects without archetype as shadow objects instead 2024-07-01 07:04:50 +02:00
2d11bf6640 Reapply "fix: energy system catalogue and importers are modified"
This reverts commit 9adacadc2a.
2024-06-27 17:21:43 -04:00
9adacadc2a Revert "fix: energy system catalogue and importers are modified"
This reverts commit 15e43a0f35.
2024-06-27 15:33:04 -04:00
15e43a0f35 fix: energy system catalogue and importers are modified 2024-06-27 15:18:26 -04:00
6dbff12ff9 Update hub/version.py 2024-06-27 10:35:47 -04:00
982bcab045 IDFL Add objects without archetype as shadow objects instead 2024-06-27 16:35:24 +02:00
83d308e03b Merge branch 'main' of https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub 2024-06-27 16:25:02 +02:00
915170e60f Bugfix: now surfaces has associated thermal boundaries after construction factory 2024-06-27 16:22:57 +02:00
6afc076402 Merge pull request 'Delete all __pycache__ files' (#62) from fix/remove-pycaches into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/62
2024-06-18 10:50:46 -04:00
6e79541816 Delete all __pycache__ files 2024-06-17 19:08:52 -04:00
c36ce1b83a Correct future warning 2024-05-27 18:09:40 +02:00
3de2e00a54 Update hub/version.py 2024-05-24 05:24:16 -04:00
5fb31fc5ca Merge remote-tracking branch 'origin/main' 2024-05-24 11:23:53 +02:00
7851968bdc Add get city to the control 2024-05-24 11:23:47 +02:00
6684e7ef1b Update hub/version.py 2024-05-24 05:20:25 -04:00
64449aee1d Merge remote-tracking branch 'origin/main' 2024-05-24 11:19:49 +02:00
a0f7ca0e17 Update idf 2024-05-24 11:19:43 +02:00
58d84021cf Update hub/version.py 2024-05-15 10:10:45 -04:00
84d80d5d2a Merge remote-tracking branch 'origin/main' 2024-05-15 16:04:15 +02:00
6b3110d1c0 Update idf 2024-05-15 16:04:08 +02:00
f095483b36 Update hub/version.py 2024-05-13 01:41:22 -04:00
841098b615 fix: energy storage bug is fixed. 2024-05-10 13:27:29 -04:00
73e6dcdaf7 Update hub/version.py 2024-04-29 00:08:21 -04:00
8fe002a22c Merge remote-tracking branch 'origin/main' 2024-04-29 06:02:49 +02:00
ffd0367d50 Bugfix in sra export 2024-04-29 06:02:43 +02:00
f15401c148 Update hub/version.py 2024-04-18 01:43:18 -04:00
9a99f69bdf Merge remote-tracking branch 'origin/main' 2024-04-18 07:42:27 +02:00
fe99059e5a Bugfix in montreal custom catalog 2024-04-18 07:42:19 +02:00
d9d9a628b4 Update hub/version.py 2024-04-16 01:02:37 -04:00
d9a941a97a Correct unittests 2024-04-16 07:01:51 +02:00
b52e66c263 bugfix in heating peak load units 2024-04-15 07:13:53 +02:00
039a0f30ba Update hub/version.py 2024-04-03 01:18:06 -04:00
ebeafddc74 Update hub/version.py 2024-03-28 02:00:40 -04:00
355cc6ecdf bugfix in idf exporter 2024-03-28 06:59:57 +01:00
cbe720f0de Update hub/version.py 2024-03-27 12:08:52 -04:00
52382566d3 bugfix: correct minimal idf 2024-03-27 17:08:08 +01:00
4056a2ab8a Update hub/version.py 2024-03-26 01:05:46 -04:00
1f7b4924fe Merge remote-tracking branch 'origin/main' 2024-03-26 06:04:34 +01:00
20200f0efe Update hub/version.py 2024-03-25 12:47:13 -04:00
919ab60bd5 bugfix in emission systems 2024-03-25 17:27:02 +01:00
aa85473a81 Update hub/version.py 2024-03-25 10:40:46 -04:00
aac006f63a Merge remote-tracking branch 'origin/main' 2024-03-25 15:35:42 +01:00
199d7dc4f9 bugfix in emission systems 2024-03-25 15:35:00 +01:00
3a6a712cad Update hub/version.py 2024-03-25 10:10:56 -04:00
27291ad1b8 bugfix in emission systems 2024-03-25 15:10:03 +01:00
5fdfee9265 update version.py 2024-03-14 14:19:09 +01:00
0f0a923329 Merge pull request 'final_energy_system_model' (#60) from final_energy_system_model into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/60
2024-03-14 09:13:21 -04:00
bf23730281 correct the unit tests 2024-03-12 16:21:43 +01:00
11d493ba0e remove north_america catalog for energy systems 2024-03-12 14:56:22 +01:00
1266f50e29 Correct small error in unittest 2024-02-16 06:01:54 +01:00
674393970c Merge remote-tracking branch 'origin/main' into final_energy_system_model
# Conflicts:
#	.gitignore
#	hub/city_model_structure/building.py
#	hub/exports/building_energy/idf.py
#	hub/imports/geometry_factory.py
2024-02-16 05:50:45 +01:00
8d75fe1f3a remove pychache 2024-02-16 05:38:07 +01:00
57a9d24f4c Title: Improvement of Energy System Parameters Importer
>> To make life easier for people who want to work on energy systems in future, I tried to make my code as generic as possible.
2024-02-13 20:05:03 -05:00
087fead489 Title: Finalizing the energy system data model and system factory
A new XML file named montreal_future_systems.xml is created where the elements of the file are the same as attributes of various classes. Therefore, the catalogue importer and energy system importer should have been updated accordingly. The catalog importer is organized in a general method so whenever someone wants to create a new catalogue they can use the created code as the blueprint.
2024-02-07 20:51:10 -05:00
ebaec9bb7c Title: Finalizing the energy system data model and system factory
A new XML file named montreal_future_systems.xml is created where the elements of the file are the same as attributes of various classes. Therefore, the catalogue importer and energy system importer should have been updated accordingly. The catalog importer is organized in a general method so whenever someone wants to create a new catalogue they can use the created code as the blueprint.
2024-02-07 18:54:09 -05:00
3e193f04a6 The dual_supply_capability is added to the city model structure 2024-02-01 15:41:05 -05:00
ac4742d2c4 A new attribute "dual_supply_capability" is added to NonPVGeneration class in non_pv_generation_system.py and the catalogue importer is adjusted 2024-02-01 12:24:15 -05:00
f976040f45 A new attribute "dual_supply_capability" is added to NonPVGeneration class in non_pv_generation_system.py and the catalogue importer is adjusted 2024-02-01 12:23:58 -05:00
54b62ec2d0 update version 2024-01-25 06:57:33 +01:00
9357cef641 remove wrong indentation 2024-01-25 06:57:00 +01:00
002d5a659d Update hub/version.py 2024-01-22 12:48:42 -05:00
f9815dfa49 Update hub/version.py 2024-01-22 08:36:05 -05:00
eeda66f410 Merge pull request 'feature/upgrade_ep_to_23.2.0' (#59) from feature/upgrade_ep_to_23.2.0 into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/59
2024-01-22 08:34:47 -05:00
aa0f790d8e remove commented code and debug prints 2024-01-22 14:33:44 +01:00
e0e7daf64b Merge remote-tracking branch 'origin/main' into feature/upgrade_ep_to_23.2.0
# Conflicts:
#	hub/exports/building_energy/idf_files/Minimal.idf
2024-01-22 14:32:24 +01:00
5181ddcabb Update hub/version.py 2024-01-18 00:33:39 -05:00
68457b9d26 add nrcan data to the pip package 2024-01-18 06:32:44 +01:00
673cbac77a added storage_medium attribute to thermal_storage_system.py to enable us use water thermodynamic characteristics in the modelling 2024-01-17 13:05:10 -05:00
11f78ccb89 added storage_medium attribute to thermal_storage_system.py to enable us use water thermodynamic characteristics in the modelling 2024-01-10 16:10:42 -05:00
3891c866cf Merge branch 'bug/units' 2024-01-09 14:01:29 +01:00
5230da861c correct units according to oriol's instruction 2024-01-09 14:00:33 +01:00
87b2319fda Update hub/version.py 2024-01-09 07:48:37 -05:00
1916d21c4e restore unittests after debug is completed 2024-01-09 10:32:47 +01:00
57388a9dc4 replace github nrel with cerc offline nrcan_data 2024-01-09 10:31:59 +01:00
89d0d0eae8 replace github nrel with cerc nrcan_data, this may also be local instead 2024-01-09 10:15:43 +01:00
e025510c93 Merge pull request 'ep_23.2.0' (#58) from ep_23.2.0 into main
Reviewed-on: https://nextgenerations-cities.encs.concordia.ca/gitea/CERC/hub/pulls/58
2023-12-07 13:22:23 -05:00
d592de6759 Surfaces have now a more human-readable name 2023-12-07 13:20:21 -05:00
eeac9a24a8 Update energy plus
Shadow object surfaces are now building_name_{index}
Now version 23.2 is supported
Minimal.idf set the proper simulation method
2023-12-07 12:05:59 -05:00
7328118861 Add debugging code to idf.py 2023-12-06 16:20:35 -05:00
9444de6bae Update add minimal.idf and energy+.idd for energyplus 23.2.0 2023-12-06 16:15:35 -05:00
27ceed01fe persistence changes 2023-12-06 15:15:36 -05:00
57c7a76529 The ep results importer for multiple buildings is completed 2023-12-06 13:53:31 -05:00
020190829f The energy plus result importer for multiple buildings is created and tested. Currently, buildings are enriched with hourly values but monthly and yearly values are not working. 2023-12-05 19:38:11 -05:00
c3f2cfb02a updated the idf.py 2023-12-05 13:13:19 -05:00
e3f1d52a21 Add .gitignore to exclude Python bytecode files 2023-12-05 12:47:44 -05:00
898f364e28 Add additional idfobjects, keys, and cleaned up syntax 2023-11-24 14:45:27 -05:00
227685695a All working, missing Sizing:Zone and DesignSpecification:OutdoorAir 2023-11-17 15:08:57 -05:00
ac6b023080 Air terminal working, air distribution not yet 2023-11-17 08:55:37 -05:00
383a480f65 Nodelist working 2023-11-17 08:13:53 -05:00
cfd2586f80 Tests to incorporate HVAC systems to EP workflow 2023-11-16 15:52:00 -05:00
a3c5219ccd Changed idf to start producing detailed systems 2023-11-16 14:26:41 -05:00
9c1e05939a The city energy system importer for the north america is modified and tested. 2023-10-17 17:25:13 -04:00
978cc9d1ea added system schematics to the data folder and to the catalog importer 2023-10-16 17:48:42 -04:00
0240e89170 modified a small bug in north_america_energy_system_catalog.py 2023-10-16 17:24:39 -04:00
c6d4feec89 Modified the classes and the north amercia catalog importer based on the changes Pilar made in the data model structure 2023-10-16 16:44:53 -04:00
3f649fd020 finished central data model new structure for energy systems, importer and test 2023-10-13 13:31:46 -04:00
d94bce4174 half made changes in central data model for systems 2023-10-13 08:23:40 -04:00
1a7ad20135 new catalog model and factory finished and test passed 2023-10-12 11:59:52 -04:00
57ee3e734b finished generic system and system parts 2023-10-11 09:14:38 -04:00
84f5ebe4a0 checking a problem with lists assignation where a single value should be assigned 2023-10-10 16:22:45 -04:00
11dc02d0e8 starting point, not working 2023-10-10 05:03:31 -04:00
d29161b05e rolled back and error introduced in a previous commit 2023-10-06 04:54:20 -04:00
a331dce966 fixed error in logic in _create_generic_systems 2023-10-06 04:14:52 -04:00
3f91da9f45 Merge remote-tracking branch 'origin/energy_system_central_data_model' into energy_system_central_data_model
# Conflicts:
#	hub/imports/energy_systems/montreal_custom_energy_system_parameters.py
2023-10-06 04:13:32 -04:00
f13d7fd860 fixed error in logic in _associate_energy_systems 2023-10-06 04:11:56 -04:00
ef89da8552 created a loop for generation systems in _associate_energy_systems 2023-10-05 16:18:08 -04:00
9654bee978 modified the names and changed all singulars to plurals 2023-10-05 14:45:33 -04:00
dae117fb44 Merge remote-tracking branch 'origin/energy_plus_result_factory' into energy_plus_result_factory 2023-10-05 14:20:24 -04:00
91fa9d5ca1 modified the names and changed all singulars to plurals 2023-10-05 14:20:02 -04:00
8e145eefa1 Merge remote-tracking branch 'origin/energy_system_central_data_model' into energy_system_central_data_model 2023-10-05 13:22:42 -04:00
6f40a15609 Merge remote-tracking branch 'origin/energy_system_central_data_model' into energy_system_central_data_model 2023-10-05 13:22:32 -04:00
4a14deece1 Merge remote-tracking branch 'origin/energy_system_central_data_model' into energy_system_central_data_model 2023-10-05 13:22:19 -04:00
ca48d6448b changed all the singular names to plural and turned distribution and emission systems into lists 2023-10-05 13:18:57 -04:00
f2bfc297b3 Basic style correction and missing docstrings 2023-10-05 11:30:20 +02:00
d5c443a57b Merge remote-tracking branch 'origin/main' into energy_system_central_data_model 2023-10-05 11:02:13 +02:00
cbda6ce13d Tried to modify the test_systems_factory.py but received an error saying GenerationSystem object is not iterable 2023-10-04 17:07:19 -04:00
f0ad1462d0 finished the first part of the test. 2023-10-03 17:50:17 -04:00
23a8fbe86d continued working on the importer 2023-10-03 13:07:20 -04:00
087384475f changing from generation system to generation systemS in system importer north america 2023-10-03 09:40:32 -04:00
fac6844da1 started working on the test 2023-10-02 13:19:58 -04:00
b914c9e7bf made final changes to north_america_custom_energy_system_parameters.py 2023-10-02 12:39:30 -04:00
eaa3064a3f continued working on energy system importer 2023-09-28 19:19:32 -04:00
8dbbfb9460 finished creating generic generation system in the _create_generic_systems method in north_america_custom_energy_system_parameters.py 2023-09-27 17:48:23 -04:00
3809cf2885 continued the work on importer 2023-09-27 13:00:04 -04:00
8b66e20e9a some refactoring 2023-09-27 05:35:28 -04:00
6d34e41e90 Started working on north america energy system importer. 2023-09-26 18:54:58 -04:00
4ce9f99e4d cleaning mix-branches 2023-09-25 03:41:52 -04:00
e3c9c64e9f Merge remote-tracking branch 'origin/Stochastic_occupancy_model' into energy_plus_result_factory
# Conflicts:
#	.gitignore
2023-09-25 03:35:51 -04:00
cb3e100fd4 I completed the generation_system.py
Created generic_storage_system.py, thermal_storage_system.py, and electrical_storage_system.py and added them to energy_system.py and generic_energy_system.py
2023-09-19 20:35:08 -04:00
41cf280aab work started on generation_system.py and generic_generation_system.py 2023-09-18 15:55:50 -04:00
ee875859e8 work started on generation_system.py and generic_generation_system.py 2023-09-18 15:44:52 -04:00
73dffdc367 Merge branch 'systems_catalog_improvement' into energy_plus_result_factory
# Conflicts:
#	.gitignore
2023-09-14 12:34:50 -04:00
b24a616d00 modified energy plus results importer test 2023-09-14 12:03:50 -04:00
707b42f2a9 modified the test checking if it only returns the hourly, monthly and yearly demands for building 12 2023-09-13 16:36:27 -04:00
cd7104206a changed name of test file 2023-09-13 04:40:11 -04:00
f0ffc26348 tried to create a test 2023-09-12 13:16:00 -04:00
cde3bfb4ae tried to get monthly values from the method in helpers/monthly values. 2023-09-08 11:50:20 -04:00
8f8a6dbf71 small changes in importer 2023-09-08 05:05:58 -04:00
1392c05489 results_factory.py is modified
The enrich method is added to energy_plus_workflow.py
The Levis_out.csv is added to test_data
2023-09-07 18:16:07 -04:00
a0d2f7e5bc chnages were made to energy_plus_workflow.py 2023-09-06 14:55:14 -04:00
c072527dc6 small changes to pv_generation_system.py 2023-08-29 14:03:30 -04:00
56c84ad399 solved bugs in adapting montreal_custom_catalog.py to new catalog data 2023-08-29 13:29:51 -04:00
a5f70f4720 erased forgotten not needed print 2023-08-29 13:12:56 -04:00
b7c2bbae96 removed last two values in generationSystems as they are not used anymore 2023-08-29 13:02:28 -04:00
8763523d3b added S to some lists, updated montreal_custom_catalog.py to new catalog classes and removed __future__ from those classes that didn't need it 2023-08-29 12:50:49 -04:00
7810f8f91d extracted storage type from abstract class 2023-08-29 12:34:04 -04:00
d4b424357d added to_dictionary to abstract class 2023-08-29 12:31:06 -04:00
8dbeeaafa1 changed some units in electrical storage 2023-08-29 12:29:11 -04:00
c77b2254f1 separated storage class in three, one abstract 2023-08-29 12:26:19 -04:00
b1d42ee00b Merge remote-tracking branch 'origin/systems_catalog_improvement' into systems_catalog_improvement
# Conflicts:
#	hub/catalog_factories/data_models/energy_systems/electrical_storage_system.py
#	hub/catalog_factories/data_models/energy_systems/energy_storage_system.py
#	hub/catalog_factories/data_models/energy_systems/thermal_storage_system.py
2023-08-29 12:25:04 -04:00
6ac63adaaf separated storage class in three, one abstract 2023-08-29 12:22:06 -04:00
644b1c9346 energy_storage_system.py is modified and inherited by thermal_storage_system.py and electrical_storage_system.py 2023-08-29 11:45:02 -04:00
24a670755a performance_curves.py is fixed
material_name is replaced with material_id in north_america_energy_system_catalog.py
The unused variables are fixed.
The code is modified to accommodate the reorganization Pilar did in generation_systems
The system.py is modified to be able to accommodate more than one distribution or emission system
2023-08-28 18:37:55 -04:00
5d4813f2f6 some changes in code to be reviewed by Saeed 2023-08-28 10:18:18 -04:00
43e5bb7310 nothing is changed 2023-08-25 10:22:46 -04:00
fe0a2d3003 north_america_energy_system_catalog.py is completed and all the bugs have been resolved. 2023-08-24 15:09:17 -04:00
3deb63b14a north_america_energy_system_catalog.py is completed
montreal_custom_catalog.py is fixed
2023-08-23 17:09:55 -04:00
9b0bdf2b7e load_generation and load_storage in north_america_energy_system_catalog.py is completed 2023-08-22 19:09:35 -04:00
072d2a6d9d modifications done to the xml file and north_america_energy_system_catalog.py 2023-08-21 17:41:12 -04:00
72b5ff1040 north_america_components.xml is modified
The montreal_custom_catalog.py is modified
2023-08-18 18:22:10 -04:00
e20a700deb emission_system.py is rolled back to original
performance_curves.py is imported in generation_system.py
The order of arguments in pv_generation_system.py is fixed
Modulation range is replaced with maximum and minimum heat output in generation_system.py
maximum,minimum, and nominal cooling output are also added to generation_system.py
2023-08-17 18:48:48 -04:00
0528aa0718 started to work on systems 2023-08-16 20:07:24 -04:00
923b1fe267 generation components are all added to north_america_energy_system_catalog.py
pv_generation_system.py is modified
Tools4CitiesESMF.xml is modified
2023-08-16 19:33:18 -04:00
32a40f17a6 fixing pv problem 2023-08-16 16:28:20 -04:00
e91e61741e add generation and config 2023-08-16 15:58:49 -04:00
16618fb54a started north america energy system catalog importer. NOT WORKING 2023-08-15 16:27:05 -04:00
21ca1e1e28 modified energy_storage_system.py and energy_system_catalog.py generation_system.py
The xml data is modified
2023-08-15 14:49:17 -04:00
ccdc7a454d small changes to performance_curves.py and distribution_system.py
created the montreal_custom_catalog_new.py
uploaded my xml file
2023-08-14 20:26:37 -04:00
3feecac15d cogeneration ratio was removed from generation_system.py
pv_generation_system.py is completed by adding an inheritance from the GenerationSystem class
parameter_function.py is renamed to performance_curves.py and an attribute to get the list of target parameters is added to it
system.py is modified by adding energy storage, performance curves, pv to it
2023-08-14 20:00:17 -04:00
acd7ad2266 distribution_system.py is modified 2023-08-13 22:53:43 -04:00
6ce82c52de Class parameter_function.py is created 2023-08-13 21:17:03 -04:00
d6ee3d6e6b All the attributes related to the material and insulation of the tank are substituted with one attribute called "layers" 2023-08-13 20:44:14 -04:00
231e4a17f2 All the attributes related to the material and insulation of the tank are substituted with one attribute called "layers" 2023-08-13 20:43:05 -04:00
012076492f Merge remote-tracking branch 'origin/systems_catalog_improvement' into systems_catalog_improvement 2023-08-13 10:27:00 -04:00
61d4c012dc Renamed the electricity_generation_system.py to pv_generation_system.py and modified the heating_generation_system to generation_system.py to account for all the generation systems. 2023-08-13 10:26:36 -04:00
1b3a128f33 added .gitignore to always ignore .idea 2023-08-11 10:18:33 -04:00
fde6f0f751 Few modifications were mafe to heat_generation_system.py and electricity_generation_system.py classes.
A new class named energy_storage_system.py is created to represent different possible energy storage systems in energy systems.
2023-08-10 20:55:35 -04:00
9034c3375e The generation_system.py is renamed to heat_generation_system.py and the attributes and decorators are modified to encapsulate all the needed attributes for boilers and heat pumps.
Another class named electricity_generation_system.py is created to add the attributes and decorators of PV, inverter, and maybe wind turbines in future. The system.py is also modified accordingly
2023-08-09 19:32:01 -04:00
2b95173dfc starting updates in system catalog 2023-08-09 12:02:16 -04:00
7f5cde8175 starting updates in system catalog 2023-08-09 11:25:56 -04:00
171 changed files with 98341 additions and 3732 deletions

View File

@ -22,6 +22,7 @@ class EilatCatalog(Catalog):
"""
Eilat catalog class
"""
def __init__(self, path):
_path_archetypes = Path(path / 'eilat_archetypes.json').resolve()
_path_constructions = (path / 'eilat_constructions.json').resolve()
@ -121,8 +122,10 @@ class EilatCatalog(Catalog):
construction_period = archetype['period_of_construction']
average_storey_height = archetype['average_storey_height']
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_off = archetype[
'infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_on = archetype[
'infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
archetype_constructions = []
for archetype_construction in archetype['constructions']:
@ -160,7 +163,9 @@ class EilatCatalog(Catalog):
extra_loses_due_to_thermal_bridges,
None,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on))
infiltration_rate_for_ventilation_system_on,
0,
0))
return _catalog_archetypes
def names(self, category=None):

View File

@ -128,6 +128,12 @@ class NrcanCatalog(Catalog):
infiltration_rate_for_ventilation_system_on = (
archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
)
infiltration_rate_area_for_ventilation_system_off = (
archetype['infiltration_rate_area_for_ventilation_system_off'] * 1
)
infiltration_rate_area_for_ventilation_system_on = (
archetype['infiltration_rate_area_for_ventilation_system_on'] * 1
)
archetype_constructions = []
for archetype_construction in archetype['constructions']:
@ -153,7 +159,6 @@ class NrcanCatalog(Catalog):
_window)
archetype_constructions.append(_construction)
break
_catalog_archetypes.append(Archetype(archetype_id,
name,
function,
@ -165,7 +170,10 @@ class NrcanCatalog(Catalog):
extra_loses_due_to_thermal_bridges,
None,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on))
infiltration_rate_for_ventilation_system_on,
infiltration_rate_area_for_ventilation_system_off,
infiltration_rate_area_for_ventilation_system_on
))
return _catalog_archetypes
def names(self, category=None):

View File

@ -162,7 +162,9 @@ class NrelCatalog(Catalog):
extra_loses_due_to_thermal_bridges,
indirect_heated_ratio,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on))
infiltration_rate_for_ventilation_system_on,
0,
0))
return _catalog_archetypes
def names(self, category=None):

View File

@ -0,0 +1,242 @@
"""
Palma construction catalog
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Cecilia Pérez Pérez cperez@irec.cat
"""
import json
from pathlib import Path
from hub.catalog_factories.catalog import Catalog
from hub.catalog_factories.data_models.construction.content import Content
from hub.catalog_factories.construction.construction_helper import ConstructionHelper
from hub.catalog_factories.data_models.construction.construction import Construction
from hub.catalog_factories.data_models.construction.archetype import Archetype
from hub.catalog_factories.data_models.construction.window import Window
from hub.catalog_factories.data_models.construction.material import Material
from hub.catalog_factories.data_models.construction.layer import Layer
import hub.helpers.constants as cte
class PalmaCatalog(Catalog):
"""
Palma catalog class
"""
def __init__(self, path):
_path_archetypes = Path(path / 'palma_archetypes.json').resolve()
_path_constructions = (path / 'palma_constructions.json').resolve()
with open(_path_archetypes, 'r', encoding='utf-8') as file:
self._archetypes = json.load(file)
with open(_path_constructions, 'r', encoding='utf-8') as file:
self._constructions = json.load(file)
self._catalog_windows = self._load_windows()
self._catalog_materials = self._load_materials()
self._catalog_constructions = self._load_constructions()
self._catalog_archetypes = self._load_archetypes()
# store the full catalog data model in self._content
self._content = Content(self._catalog_archetypes,
self._catalog_constructions,
self._catalog_materials,
self._catalog_windows)
def _load_windows(self):
_catalog_windows = []
windows = self._constructions['transparent_surfaces']
for window in windows:
name = list(window.keys())[0]
window_id = name
g_value = window[name]['shgc']
window_type = window[name]['type']
frame_ratio = window[name]['frame_ratio']
overall_u_value = window[name]['u_value']
_catalog_windows.append(Window(window_id, frame_ratio, g_value, overall_u_value, name, window_type))
return _catalog_windows
def _load_materials(self):
_catalog_materials = []
materials = self._constructions['materials']
for material in materials:
name = list(material.keys())[0]
material_id = name
no_mass = material[name]['no_mass']
thermal_resistance = None
conductivity = None
density = None
specific_heat = None
solar_absorptance = None
thermal_absorptance = None
visible_absorptance = None
if no_mass:
thermal_resistance = material[name]['thermal_resistance']
else:
solar_absorptance = material[name]['solar_absorptance']
thermal_absorptance = str(1 - float(material[name]['thermal_emittance']))
visible_absorptance = material[name]['visible_absorptance']
conductivity = material[name]['conductivity']
density = material[name]['density']
specific_heat = material[name]['specific_heat']
_material = Material(material_id,
name,
solar_absorptance,
thermal_absorptance,
visible_absorptance,
no_mass,
thermal_resistance,
conductivity,
density,
specific_heat)
_catalog_materials.append(_material)
return _catalog_materials
def _load_constructions(self):
_catalog_constructions = []
constructions = self._constructions['opaque_surfaces']
for construction in constructions:
name = list(construction.keys())[0]
construction_id = name
construction_type = ConstructionHelper().nrcan_surfaces_types_to_hub_types[construction[name]['type']]
layers = []
for layer in construction[name]['layers']:
layer_id = layer
layer_name = layer
material_id = layer
thickness = construction[name]['layers'][layer]
for material in self._catalog_materials:
if str(material_id) == str(material.id):
layers.append(Layer(layer_id, layer_name, material, thickness))
break
_catalog_constructions.append(Construction(construction_id, construction_type, name, layers))
return _catalog_constructions
def _load_archetypes(self):
_catalog_archetypes = []
archetypes = self._archetypes['archetypes']
for archetype in archetypes:
archetype_id = f'{archetype["function"]}_{archetype["period_of_construction"]}_{archetype["climate_zone"]}'
function = archetype['function']
name = archetype_id
climate_zone = archetype['climate_zone']
construction_period = archetype['period_of_construction']
average_storey_height = archetype['average_storey_height']
thermal_capacity = float(archetype['thermal_capacity']) * 1000
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
infiltration_rate_area_for_ventilation_system_off = (
archetype['infiltration_rate_area_for_ventilation_system_off'] * 1
)
infiltration_rate_area_for_ventilation_system_on = (
archetype['infiltration_rate_area_for_ventilation_system_on'] * 1
)
archetype_constructions = []
for archetype_construction in archetype['constructions']:
archetype_construction_type = ConstructionHelper().nrcan_surfaces_types_to_hub_types[archetype_construction]
archetype_construction_name = archetype['constructions'][archetype_construction]['opaque_surface_name']
for construction in self._catalog_constructions:
if archetype_construction_type == construction.type and construction.name == archetype_construction_name:
_construction = None
_window = None
_window_ratio = None
if 'transparent_surface_name' in archetype['constructions'][archetype_construction].keys():
_window_ratio = archetype['constructions'][archetype_construction]['transparent_ratio']
_window_id = archetype['constructions'][archetype_construction]['transparent_surface_name']
for window in self._catalog_windows:
if _window_id == window.id:
_window = window
break
_construction = Construction(construction.id,
construction.type,
construction.name,
construction.layers,
_window_ratio,
_window)
archetype_constructions.append(_construction)
break
_catalog_archetypes.append(Archetype(archetype_id,
name,
function,
climate_zone,
construction_period,
archetype_constructions,
average_storey_height,
thermal_capacity,
extra_loses_due_to_thermal_bridges,
None,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on,
infiltration_rate_area_for_ventilation_system_off,
infiltration_rate_area_for_ventilation_system_on))
return _catalog_archetypes
def names(self, category=None):
"""
Get the catalog elements names
:parm: optional category filter
"""
if category is None:
_names = {'archetypes': [], 'constructions': [], 'materials': [], 'windows': []}
for archetype in self._content.archetypes:
_names['archetypes'].append(archetype.name)
for construction in self._content.constructions:
_names['constructions'].append(construction.name)
for material in self._content.materials:
_names['materials'].append(material.name)
for window in self._content.windows:
_names['windows'].append(window.name)
else:
_names = {category: []}
if category.lower() == 'archetypes':
for archetype in self._content.archetypes:
_names[category].append(archetype.name)
elif category.lower() == 'constructions':
for construction in self._content.constructions:
_names[category].append(construction.name)
elif category.lower() == 'materials':
for material in self._content.materials:
_names[category].append(material.name)
elif category.lower() == 'windows':
for window in self._content.windows:
_names[category].append(window.name)
else:
raise ValueError(f'Unknown category [{category}]')
return _names
def entries(self, category=None):
"""
Get the catalog elements
:parm: optional category filter
"""
if category is None:
return self._content
if category.lower() == 'archetypes':
return self._content.archetypes
if category.lower() == 'constructions':
return self._content.constructions
if category.lower() == 'materials':
return self._content.materials
if category.lower() == 'windows':
return self._content.windows
raise ValueError(f'Unknown category [{category}]')
def get_entry(self, name):
"""
Get one catalog element by names
:parm: entry name
"""
for entry in self._content.archetypes:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.constructions:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.materials:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.windows:
if entry.name.lower() == name.lower():
return entry
raise IndexError(f"{name} doesn't exists in the catalog")

View File

@ -11,6 +11,7 @@ from typing import TypeVar
from hub.catalog_factories.construction.nrcan_catalog import NrcanCatalog
from hub.catalog_factories.construction.nrel_catalog import NrelCatalog
from hub.catalog_factories.construction.eilat_catalog import EilatCatalog
from hub.catalog_factories.construction.palma_catalog import PalmaCatalog
from hub.helpers.utils import validate_import_export_type
Catalog = TypeVar('Catalog')
@ -48,6 +49,13 @@ class ConstructionCatalogFactory:
"""
return EilatCatalog(self._path)
@property
def _palma(self):
"""
Retrieve Palma catalog
"""
return PalmaCatalog(self._path)
@property
def catalog(self) -> Catalog:
"""

View File

@ -23,7 +23,10 @@ class Archetype:
extra_loses_due_to_thermal_bridges,
indirect_heated_ratio,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on):
infiltration_rate_for_ventilation_system_on,
infiltration_rate_area_for_ventilation_system_off,
infiltration_rate_area_for_ventilation_system_on
):
self._id = archetype_id
self._name = name
self._function = function
@ -36,6 +39,8 @@ class Archetype:
self._indirect_heated_ratio = indirect_heated_ratio
self._infiltration_rate_for_ventilation_system_off = infiltration_rate_for_ventilation_system_off
self._infiltration_rate_for_ventilation_system_on = infiltration_rate_for_ventilation_system_on
self._infiltration_rate_area_for_ventilation_system_off = infiltration_rate_area_for_ventilation_system_off
self._infiltration_rate_area_for_ventilation_system_on = infiltration_rate_area_for_ventilation_system_on
@property
def id(self):
@ -133,6 +138,22 @@ class Archetype:
"""
return self._infiltration_rate_for_ventilation_system_on
@property
def infiltration_rate_area_for_ventilation_system_off(self):
"""
Get archetype infiltration rate for ventilation system off in m3/sm2
:return: float
"""
return self._infiltration_rate_area_for_ventilation_system_off
@property
def infiltration_rate_area_for_ventilation_system_on(self):
"""
Get archetype infiltration rate for ventilation system on in m3/sm2
:return: float
"""
return self._infiltration_rate_for_ventilation_system_on
def to_dictionary(self):
"""Class content to dictionary"""
_constructions = []
@ -149,6 +170,8 @@ class Archetype:
'indirect heated ratio': self.indirect_heated_ratio,
'infiltration rate for ventilation off [1/s]': self.infiltration_rate_for_ventilation_system_off,
'infiltration rate for ventilation on [1/s]': self.infiltration_rate_for_ventilation_system_on,
'infiltration rate area for ventilation off [m3/sm2]': self.infiltration_rate_area_for_ventilation_system_off,
'infiltration rate area for ventilation on [m3/sm2]': self.infiltration_rate_area_for_ventilation_system_on,
'constructions': _constructions
}
}

View File

@ -1,8 +1,9 @@
"""
Energy System catalog archetype
Energy System catalog archetype, understood as a cluster of energy systems
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from typing import List
@ -14,19 +15,19 @@ class Archetype:
"""
Archetype class
"""
def __init__(self, lod, name, systems):
self._lod = lod
def __init__(self, name, systems, archetype_cluster_id=None):
self._cluster_id = archetype_cluster_id
self._name = name
self._systems = systems
@property
def lod(self):
def cluster_id(self):
"""
Get level of detail of the catalog
Get id
:return: string
"""
return self._lod
return self._cluster_id
@property
def name(self):
@ -49,9 +50,11 @@ class Archetype:
_systems = []
for _system in self.systems:
_systems.append(_system.to_dictionary())
content = {'Archetype': {'name': self.name,
'level of detail': self.lod,
'systems': _systems
}
}
content = {
'Archetype': {
'cluster_id': self.cluster_id,
'name': self.name,
'systems': _systems
}
}
return content

View File

@ -10,12 +10,11 @@ class Content:
"""
Content class
"""
def __init__(self, archetypes, systems, generations, distributions, emissions):
def __init__(self, archetypes, systems, generations=None, distributions=None):
self._archetypes = archetypes
self._systems = systems
self._generations = generations
self._distributions = distributions
self._emissions = emissions
@property
def archetypes(self):
@ -45,13 +44,6 @@ class Content:
"""
return self._distributions
@property
def emission_equipments(self):
"""
All emission equipments in the catalog
"""
return self._emissions
def to_dictionary(self):
"""Class content to dictionary"""
_archetypes = []

View File

@ -3,23 +3,35 @@ Energy System catalog distribution system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from typing import Union, List, TypeVar
from hub.catalog_factories.data_models.energy_systems.energy_storage_system import EnergyStorageSystem
from hub.catalog_factories.data_models.energy_systems.emission_system import EmissionSystem
GenerationSystem = TypeVar('GenerationSystem')
class DistributionSystem:
"""
Distribution system class
"""
def __init__(self, system_id, name, system_type, supply_temperature, distribution_consumption_fix_flow,
distribution_consumption_variable_flow, heat_losses):
def __init__(self, system_id, model_name=None, system_type=None, supply_temperature=None,
distribution_consumption_fix_flow=None, distribution_consumption_variable_flow=None, heat_losses=None,
generation_systems=None, energy_storage_systems=None, emission_systems=None):
self._system_id = system_id
self._name = name
self._model_name = model_name
self._type = system_type
self._supply_temperature = supply_temperature
self._distribution_consumption_fix_flow = distribution_consumption_fix_flow
self._distribution_consumption_variable_flow = distribution_consumption_variable_flow
self._heat_losses = heat_losses
self._generation_systems = generation_systems
self._energy_storage_systems = energy_storage_systems
self._emission_systems = emission_systems
@property
def id(self):
@ -30,12 +42,12 @@ class DistributionSystem:
return self._system_id
@property
def name(self):
def model_name(self):
"""
Get name
Get model name
:return: string
"""
return self._name
return self._model_name
@property
def type(self):
@ -78,17 +90,51 @@ class DistributionSystem:
"""
return self._heat_losses
@property
def generation_systems(self) -> Union[None, List[GenerationSystem]]:
"""
Get generation systems connected to the distribution system
:return: [GenerationSystem]
"""
return self._generation_systems
@property
def energy_storage_systems(self) -> Union[None, List[EnergyStorageSystem]]:
"""
Get energy storage systems connected to this distribution system
:return: [EnergyStorageSystem]
"""
return self._energy_storage_systems
@property
def emission_systems(self) -> Union[None, List[EmissionSystem]]:
"""
Get energy emission systems connected to this distribution system
:return: [EmissionSystem]
"""
return self._emission_systems
def to_dictionary(self):
"""Class content to dictionary"""
_generation_systems = [_generation_system.to_dictionary() for _generation_system in
self.generation_systems] if self.generation_systems is not None else None
_energy_storage_systems = [_energy_storage_system.to_dictionary() for _energy_storage_system in
self.energy_storage_systems] if self.energy_storage_systems is not None else None
_emission_systems = [_emission_system.to_dictionary() for _emission_system in
self.emission_systems] if self.emission_systems is not None else None
content = {
'Layer': {
'id': self.id,
'name': self.name,
'model name': self.model_name,
'type': self.type,
'supply temperature [Celsius]': self.supply_temperature,
'distribution consumption if fix flow over peak power [W/W]': self.distribution_consumption_fix_flow,
'distribution consumption if variable flow over peak power [J/J]': self.distribution_consumption_variable_flow,
'heat losses per energy produced [J/J]': self.heat_losses
'heat losses per energy produced [J/J]': self.heat_losses,
'generation systems connected': _generation_systems,
'energy storage systems connected': _energy_storage_systems,
'emission systems connected': _emission_systems
}
}
return content

View File

@ -0,0 +1,103 @@
"""
Energy System catalog electrical storage system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from hub.catalog_factories.data_models.energy_systems.energy_storage_system import EnergyStorageSystem
class ElectricalStorageSystem(EnergyStorageSystem):
""""
Energy Storage System Class
"""
def __init__(self, storage_id, type_energy_stored=None, model_name=None, manufacturer=None, storage_type=None,
nominal_capacity=None, losses_ratio=None, rated_output_power=None, nominal_efficiency=None,
battery_voltage=None, depth_of_discharge=None, self_discharge_rate=None):
super().__init__(storage_id, model_name, manufacturer, nominal_capacity, losses_ratio)
self._type_energy_stored = type_energy_stored
self._storage_type = storage_type
self._rated_output_power = rated_output_power
self._nominal_efficiency = nominal_efficiency
self._battery_voltage = battery_voltage
self._depth_of_discharge = depth_of_discharge
self._self_discharge_rate = self_discharge_rate
@property
def type_energy_stored(self):
"""
Get type of energy stored from ['electrical', 'thermal']
:return: string
"""
return self._type_energy_stored
@property
def storage_type(self):
"""
Get storage type from ['lithium_ion', 'lead_acid', 'NiCd']
:return: string
"""
return self._storage_type
@property
def rated_output_power(self):
"""
Get the rated output power of storage system in Watts
:return: float
"""
return self._rated_output_power
@property
def nominal_efficiency(self):
"""
Get the nominal efficiency of the storage system
:return: float
"""
return self._nominal_efficiency
@property
def battery_voltage(self):
"""
Get the battery voltage in Volts
:return: float
"""
return self._battery_voltage
@property
def depth_of_discharge(self):
"""
Get the depth of discharge as a percentage
:return: float
"""
return self._depth_of_discharge
@property
def self_discharge_rate(self):
"""
Get the self discharge rate of battery as a percentage
:return: float
"""
return self._self_discharge_rate
def to_dictionary(self):
"""Class content to dictionary"""
content = {'Storage component': {
'storage id': self.id,
'type of energy stored': self.type_energy_stored,
'model name': self.model_name,
'manufacturer': self.manufacturer,
'storage type': self.storage_type,
'nominal capacity [J]': self.nominal_capacity,
'losses-ratio [J/J]': self.losses_ratio,
'rated power [W]': self.rated_output_power,
'nominal efficiency': self.nominal_efficiency,
'battery voltage [V]': self.battery_voltage,
'depth of discharge [%]': self.depth_of_discharge,
'self discharge rate': self.self_discharge_rate
}
}
return content

View File

@ -10,10 +10,10 @@ class EmissionSystem:
"""
Emission system class
"""
def __init__(self, system_id, name, system_type, parasitic_energy_consumption):
def __init__(self, system_id, model_name=None, system_type=None, parasitic_energy_consumption=0):
self._system_id = system_id
self._name = name
self._model_name = model_name
self._type = system_type
self._parasitic_energy_consumption = parasitic_energy_consumption
@ -26,12 +26,12 @@ class EmissionSystem:
return self._system_id
@property
def name(self):
def model_name(self):
"""
Get name
Get model name
:return: string
"""
return self._name
return self._model_name
@property
def type(self):
@ -52,7 +52,7 @@ class EmissionSystem:
def to_dictionary(self):
"""Class content to dictionary"""
content = {'Layer': {'id': self.id,
'name': self.name,
'model name': self.model_name,
'type': self.type,
'parasitic energy consumption per energy produced [J/J]': self.parasitic_energy_consumption
}

View File

@ -0,0 +1,75 @@
"""
Energy System catalog heat generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from abc import ABC
class EnergyStorageSystem(ABC):
""""
Energy Storage System Abstract Class
"""
def __init__(self, storage_id, model_name=None, manufacturer=None,
nominal_capacity=None, losses_ratio=None):
self._storage_id = storage_id
self._model_name = model_name
self._manufacturer = manufacturer
self._nominal_capacity = nominal_capacity
self._losses_ratio = losses_ratio
@property
def id(self):
"""
Get storage id
:return: string
"""
return self._storage_id
@property
def type_energy_stored(self):
"""
Get type of energy stored from ['electrical', 'thermal']
:return: string
"""
raise NotImplementedError
@property
def model_name(self):
"""
Get system model
:return: string
"""
return self._model_name
@property
def manufacturer(self):
"""
Get name of manufacturer
:return: string
"""
return self._manufacturer
@property
def nominal_capacity(self):
"""
Get the nominal capacity of the storage system in Jules
:return: float
"""
return self._nominal_capacity
@property
def losses_ratio(self):
"""
Get the losses-ratio of storage system in Jules lost / Jules stored
:return: float
"""
return self._losses_ratio
def to_dictionary(self):
"""Class content to dictionary"""
raise NotImplementedError

View File

@ -1,33 +1,33 @@
"""
Energy System catalog generation system
Energy System catalog heat generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from __future__ import annotations
from typing import Union
from abc import ABC
from typing import List, Union
from hub.catalog_factories.data_models.energy_systems.energy_storage_system import EnergyStorageSystem
from hub.catalog_factories.data_models.energy_systems.distribution_system import DistributionSystem
class GenerationSystem:
class GenerationSystem(ABC):
"""
Generation system class
Heat Generation system class
"""
def __init__(self, system_id, name, system_type, fuel_type, source_types, heat_efficiency, cooling_efficiency,
electricity_efficiency, source_temperature, source_mass_flow, storage, auxiliary_equipment):
def __init__(self, system_id, name, model_name=None, manufacturer=None, fuel_type=None,
distribution_systems=None, energy_storage_systems=None):
self._system_id = system_id
self._name = name
self._type = system_type
self._model_name = model_name
self._manufacturer = manufacturer
self._fuel_type = fuel_type
self._source_types = source_types
self._heat_efficiency = heat_efficiency
self._cooling_efficiency = cooling_efficiency
self._electricity_efficiency = electricity_efficiency
self._source_temperature = source_temperature
self._source_mass_flow = source_mass_flow
self._storage = storage
self._auxiliary_equipment = auxiliary_equipment
self._distribution_systems = distribution_systems
self._energy_storage_systems = energy_storage_systems
@property
def id(self):
@ -40,108 +40,59 @@ class GenerationSystem:
@property
def name(self):
"""
Get name
Get system name
:return: string
"""
return self._name
@property
def type(self):
def system_type(self):
"""
Get type
:return: string
"""
return self._type
raise NotImplementedError
@property
def model_name(self):
"""
Get system id
:return: float
"""
return self._model_name
@property
def manufacturer(self):
"""
Get name
:return: string
"""
return self._manufacturer
@property
def fuel_type(self):
"""
Get fuel_type from [renewable, gas, diesel, electricity, wood, coal]
Get fuel_type from [renewable, gas, diesel, electricity, wood, coal, biogas]
:return: string
"""
return self._fuel_type
@property
def source_types(self):
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
"""
Get source_type from [air, water, geothermal, district_heating, grid, on_site_electricity]
:return: [string]
Get distributions systems connected to this generation system
:return: [DistributionSystem]
"""
return self._source_types
return self._distribution_systems
@property
def heat_efficiency(self):
def energy_storage_systems(self) -> Union[None, List[EnergyStorageSystem]]:
"""
Get heat_efficiency
:return: float
Get energy storage systems connected to this generation system
:return: [EnergyStorageSystem]
"""
return self._heat_efficiency
@property
def cooling_efficiency(self):
"""
Get cooling_efficiency
:return: float
"""
return self._cooling_efficiency
@property
def electricity_efficiency(self):
"""
Get electricity_efficiency
:return: float
"""
return self._electricity_efficiency
@property
def source_temperature(self):
"""
Get source_temperature in degree Celsius
:return: float
"""
return self._source_temperature
@property
def source_mass_flow(self):
"""
Get source_mass_flow in kg/s
:return: float
"""
return self._source_mass_flow
@property
def storage(self):
"""
Get boolean storage exists
:return: bool
"""
return self._storage
@property
def auxiliary_equipment(self) -> Union[None, GenerationSystem]:
"""
Get auxiliary_equipment
:return: GenerationSystem
"""
return self._auxiliary_equipment
return self._energy_storage_systems
def to_dictionary(self):
"""Class content to dictionary"""
_auxiliary_equipment = []
if self.auxiliary_equipment is not None:
_auxiliary_equipment = self.auxiliary_equipment.to_dictionary()
content = {'Layer': {'id': self.id,
'name': self.name,
'type': self.type,
'fuel type': self.fuel_type,
'source types': self.source_types,
'source temperature [Celsius]': self.source_temperature,
'source mass flow [kg/s]': self.source_mass_flow,
'heat efficiency': self.heat_efficiency,
'cooling efficiency': self.cooling_efficiency,
'electricity efficiency': self.electricity_efficiency,
'it has storage': self.storage,
'auxiliary equipment': _auxiliary_equipment
}
}
return content
raise NotImplementedError

View File

@ -0,0 +1,344 @@
"""
Energy System catalog non PV generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from typing import Union
from hub.catalog_factories.data_models.energy_systems.performance_curves import PerformanceCurves
from hub.catalog_factories.data_models.energy_systems.generation_system import GenerationSystem
class NonPvGenerationSystem(GenerationSystem):
"""
Non PV Generation system class
"""
def __init__(self, system_id, name, system_type, model_name=None, manufacturer=None, fuel_type=None,
nominal_heat_output=None, maximum_heat_output=None, minimum_heat_output=None, source_medium=None,
supply_medium=None, heat_efficiency=None, nominal_cooling_output=None, maximum_cooling_output=None,
minimum_cooling_output=None, cooling_efficiency=None, electricity_efficiency=None,
source_temperature=None, source_mass_flow=None, nominal_electricity_output=None,
maximum_heat_supply_temperature=None, minimum_heat_supply_temperature=None,
maximum_cooling_supply_temperature=None, minimum_cooling_supply_temperature=None, heat_output_curve=None,
heat_fuel_consumption_curve=None, heat_efficiency_curve=None, cooling_output_curve=None,
cooling_fuel_consumption_curve=None, cooling_efficiency_curve=None,
distribution_systems=None, energy_storage_systems=None, domestic_hot_water=False,
reversible=None, simultaneous_heat_cold=None):
super().__init__(system_id=system_id, name=name, model_name=model_name, manufacturer=manufacturer,
fuel_type=fuel_type, distribution_systems=distribution_systems,
energy_storage_systems=energy_storage_systems)
self._system_type = system_type
self._nominal_heat_output = nominal_heat_output
self._maximum_heat_output = maximum_heat_output
self._minimum_heat_output = minimum_heat_output
self._heat_efficiency = heat_efficiency
self._nominal_cooling_output = nominal_cooling_output
self._maximum_cooling_output = maximum_cooling_output
self._minimum_cooling_output = minimum_cooling_output
self._cooling_efficiency = cooling_efficiency
self._electricity_efficiency = electricity_efficiency
self._nominal_electricity_output = nominal_electricity_output
self._source_medium = source_medium
self._source_temperature = source_temperature
self._source_mass_flow = source_mass_flow
self._supply_medium = supply_medium
self._maximum_heat_supply_temperature = maximum_heat_supply_temperature
self._minimum_heat_supply_temperature = minimum_heat_supply_temperature
self._maximum_cooling_supply_temperature = maximum_cooling_supply_temperature
self._minimum_cooling_supply_temperature = minimum_cooling_supply_temperature
self._heat_output_curve = heat_output_curve
self._heat_fuel_consumption_curve = heat_fuel_consumption_curve
self._heat_efficiency_curve = heat_efficiency_curve
self._cooling_output_curve = cooling_output_curve
self._cooling_fuel_consumption_curve = cooling_fuel_consumption_curve
self._cooling_efficiency_curve = cooling_efficiency_curve
self._domestic_hot_water = domestic_hot_water
self._reversible = reversible
self._simultaneous_heat_cold = simultaneous_heat_cold
@property
def system_type(self):
"""
Get type
:return: string
"""
return self._system_type
@property
def nominal_heat_output(self):
"""
Get nominal heat output of heat generation devices in W
:return: float
"""
return self._nominal_heat_output
@property
def maximum_heat_output(self):
"""
Get maximum heat output of heat generation devices in W
:return: float
"""
return self._maximum_heat_output
@property
def minimum_heat_output(self):
"""
Get minimum heat output of heat generation devices in W
:return: float
"""
return self._minimum_heat_output
@property
def source_medium(self):
"""
Get source_type from [air, water, ground, district_heating, grid, on_site_electricity]
:return: string
"""
return self._source_medium
@property
def supply_medium(self):
"""
Get the supply medium from ['air', 'water']
:return: string
"""
return self._supply_medium
@property
def heat_efficiency(self):
"""
Get heat_efficiency
:return: float
"""
return self._heat_efficiency
@property
def nominal_cooling_output(self):
"""
Get nominal cooling output of heat generation devices in W
:return: float
"""
return self._nominal_cooling_output
@property
def maximum_cooling_output(self):
"""
Get maximum heat output of heat generation devices in W
:return: float
"""
return self._maximum_cooling_output
@property
def minimum_cooling_output(self):
"""
Get minimum heat output of heat generation devices in W
:return: float
"""
return self._minimum_cooling_output
@property
def cooling_efficiency(self):
"""
Get cooling_efficiency
:return: float
"""
return self._cooling_efficiency
@property
def electricity_efficiency(self):
"""
Get electricity_efficiency
:return: float
"""
return self._electricity_efficiency
@property
def source_temperature(self):
"""
Get source_temperature in degree Celsius
:return: float
"""
return self._source_temperature
@property
def source_mass_flow(self):
"""
Get source_mass_flow in kg/s
:return: float
"""
return self._source_mass_flow
@property
def nominal_electricity_output(self):
"""
Get nominal_power_output of electricity generation devices or inverters in W
:return: float
"""
return self._nominal_electricity_output
@property
def maximum_heat_supply_temperature(self):
"""
Get the maximum heat supply temperature in degree Celsius
:return: float
"""
return self._minimum_heat_supply_temperature
@property
def minimum_heat_supply_temperature(self):
"""
Get the minimum heat supply temperature in degree Celsius
:return: float
"""
return self._minimum_heat_supply_temperature
@property
def maximum_cooling_supply_temperature(self):
"""
Get the maximum cooling supply temperature in degree Celsius
:return: float
"""
return self._maximum_cooling_supply_temperature
@property
def minimum_cooling_supply_temperature(self):
"""
Get the minimum cooling supply temperature in degree Celsius
:return: float
"""
return self._minimum_cooling_supply_temperature
@property
def heat_output_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heat output curve of the heat generation device
:return: PerformanceCurve
"""
return self._heat_output_curve
@property
def heat_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating fuel consumption curve of the heat generation device
:return: PerformanceCurve
"""
return self._heat_fuel_consumption_curve
@property
def heat_efficiency_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating efficiency curve of the heat generation device
:return: PerformanceCurve
"""
return self._heat_efficiency_curve
@property
def cooling_output_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heat output curve of the heat generation device
:return: PerformanceCurve
"""
return self._cooling_output_curve
@property
def cooling_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating fuel consumption curve of the heat generation device
:return: PerformanceCurve
"""
return self._cooling_fuel_consumption_curve
@property
def cooling_efficiency_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating efficiency curve of the heat generation device
:return: PerformanceCurve
"""
return self._cooling_efficiency_curve
@property
def domestic_hot_water(self):
"""
Get the ability to produce domestic hot water
:return: bool
"""
return self._domestic_hot_water
@property
def reversibility(self):
"""
Get the ability to produce heating and cooling
:return: bool
"""
return self._reversible
@property
def simultaneous_heat_cold(self):
"""
Get the ability to produce heating and cooling at the same time
:return: bool
"""
return self._simultaneous_heat_cold
def to_dictionary(self):
"""Class content to dictionary"""
_distribution_systems = [_distribution_system.to_dictionary() for _distribution_system in
self.distribution_systems] if self.distribution_systems is not None else None
_energy_storage_systems = [_energy_storage_system.to_dictionary() for _energy_storage_system in
self.energy_storage_systems] if self.energy_storage_systems is not None else None
_heat_output_curve = self.heat_output_curve.to_dictionary() if (
self.heat_output_curve is not None) else None
_heat_fuel_consumption_curve = self.heat_fuel_consumption_curve.to_dictionary() if (
self.heat_fuel_consumption_curve is not None) else None
_heat_efficiency_curve = self.heat_efficiency_curve.to_dictionary() if (
self.heat_efficiency_curve is not None) else None
_cooling_output_curve = self.cooling_output_curve.to_dictionary() if (
self.cooling_output_curve is not None) else None
_cooling_fuel_consumption_curve = self.cooling_fuel_consumption_curve.to_dictionary() if (
self.cooling_fuel_consumption_curve is not None) else None
_cooling_efficiency_curve = self.cooling_efficiency_curve.to_dictionary() if (
self.cooling_efficiency_curve is not None) else None
content = {
'Energy Generation component':
{
'id': self.id,
'model name': self.model_name,
'manufacturer': self.manufacturer,
'type': self.system_type,
'fuel type': self.fuel_type,
'nominal heat output [W]': self.nominal_heat_output,
'maximum heat output [W]': self.maximum_heat_output,
'minimum heat output [W]': self.minimum_heat_output,
'source medium': self.source_medium,
'supply medium': self.supply_medium,
'source temperature [Celsius]': self.source_temperature,
'source mass flow [kg/s]': self.source_mass_flow,
'heat efficiency': self.heat_efficiency,
'nominal cooling output [W]': self.nominal_cooling_output,
'maximum cooling output [W]': self.maximum_cooling_output,
'minimum cooling output [W]': self.minimum_cooling_output,
'cooling efficiency': self.cooling_efficiency,
'electricity efficiency': self.electricity_efficiency,
'nominal power output [W]': self.nominal_electricity_output,
'maximum heating supply temperature [Celsius]': self.maximum_heat_supply_temperature,
'minimum heating supply temperature [Celsius]': self.minimum_heat_supply_temperature,
'maximum cooling supply temperature [Celsius]': self.maximum_cooling_supply_temperature,
'minimum cooling supply temperature [Celsius]': self.minimum_cooling_supply_temperature,
'heat output curve': self.heat_output_curve,
'heat fuel consumption curve': self.heat_fuel_consumption_curve,
'heat efficiency curve': _heat_efficiency_curve,
'cooling output curve': self.cooling_output_curve,
'cooling fuel consumption curve': self.cooling_fuel_consumption_curve,
'cooling efficiency curve': self.cooling_efficiency_curve,
'distribution systems connected': _distribution_systems,
'storage systems connected': _energy_storage_systems,
'domestic hot water production capability': self.domestic_hot_water,
'reversible cycle': self.reversibility,
'simultaneous heat and cooling production': self.simultaneous_heat_cold
}
}
return content

View File

@ -0,0 +1,72 @@
"""
Energy System catalog heat generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from __future__ import annotations
class PerformanceCurves:
"""
Parameter function class
"""
def __init__(self, curve_type, dependant_variable, parameters, coefficients):
self._curve_type = curve_type
self._dependant_variable = dependant_variable
self._parameters = parameters
self._coefficients = coefficients
@property
def curve_type(self):
"""
The type of the fit function from the following
Linear =>>> y = a + b*x
Exponential =>>> y = a*(b**x)
Second degree polynomial =>>> y = a + b*x + c*(x**2)
Power =>>> y = a*(x**b)
Bi-Quadratic =>>> y = a + b*x + c*(x**2) + d*z + e*(z**2) + f*x*z
Get the type of function from ['linear', 'exponential', 'second degree polynomial', 'power', 'bi-quadratic']
:return: string
"""
return self._curve_type
@property
def dependant_variable(self):
"""
y (e.g. COP in COP = a*source temperature**2 + b*source temperature + c*source temperature*supply temperature +
d*supply temperature + e*supply temperature**2 + f)
"""
return self._dependant_variable
@property
def parameters(self):
"""
Get the list of parameters involved in fitting process as ['x', 'z'] (e.g. [source temperature, supply temperature]
in COP=)
:return: string
"""
return self._parameters
@property
def coefficients(self):
"""
Get the coefficients of the functions as list of ['a', 'b', 'c', 'd', 'e', 'f']
:return: [coefficients]
"""
return self._coefficients
def to_dictionary(self):
"""Class content to dictionary"""
content = {'Parameter Function': {
'curve type': self.curve_type,
'dependant variable': self.dependant_variable,
'parameter(s)': self.parameters,
'coefficients': self.coefficients,
}
}
return content

View File

@ -0,0 +1,165 @@
"""
Energy System catalog heat generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from hub.catalog_factories.data_models.energy_systems.generation_system import GenerationSystem
class PvGenerationSystem(GenerationSystem):
"""
Electricity Generation system class
"""
def __init__(self, system_id, name, system_type, model_name=None, manufacturer=None, electricity_efficiency=None,
nominal_electricity_output=None, nominal_ambient_temperature=None, nominal_cell_temperature=None,
nominal_radiation=None, standard_test_condition_cell_temperature=None,
standard_test_condition_maximum_power=None, standard_test_condition_radiation=None,
cell_temperature_coefficient=None, width=None, height=None, distribution_systems=None,
energy_storage_systems=None):
super().__init__(system_id=system_id, name=name, model_name=model_name,
manufacturer=manufacturer, fuel_type='renewable', distribution_systems=distribution_systems,
energy_storage_systems=energy_storage_systems)
self._system_type = system_type
self._electricity_efficiency = electricity_efficiency
self._nominal_electricity_output = nominal_electricity_output
self._nominal_ambient_temperature = nominal_ambient_temperature
self._nominal_cell_temperature = nominal_cell_temperature
self._nominal_radiation = nominal_radiation
self._standard_test_condition_cell_temperature = standard_test_condition_cell_temperature
self._standard_test_condition_maximum_power = standard_test_condition_maximum_power
self._standard_test_condition_radiation = standard_test_condition_radiation
self._cell_temperature_coefficient = cell_temperature_coefficient
self._width = width
self._height = height
@property
def system_type(self):
"""
Get type
:return: string
"""
return self._system_type
@property
def nominal_electricity_output(self):
"""
Get nominal_power_output of electricity generation devices or inverters in W
:return: float
"""
return self._nominal_electricity_output
@property
def electricity_efficiency(self):
"""
Get electricity_efficiency
:return: float
"""
return self._electricity_efficiency
@property
def nominal_ambient_temperature(self):
"""
Get nominal ambient temperature of PV panels in degree Celsius
:return: float
"""
return self._nominal_ambient_temperature
@property
def nominal_cell_temperature(self):
"""
Get nominal cell temperature of PV panels in degree Celsius
:return: float
"""
return self._nominal_cell_temperature
@property
def nominal_radiation(self):
"""
Get nominal radiation of PV panels
:return: float
"""
return self._nominal_radiation
@property
def standard_test_condition_cell_temperature(self):
"""
Get standard test condition cell temperature of PV panels in degree Celsius
:return: float
"""
return self._standard_test_condition_cell_temperature
@property
def standard_test_condition_maximum_power(self):
"""
Get standard test condition maximum power of PV panels in W
:return: float
"""
return self._standard_test_condition_maximum_power
@property
def standard_test_condition_radiation(self):
"""
Get standard test condition cell temperature of PV panels in W/m2
:return: float
"""
return self._standard_test_condition_radiation
@property
def cell_temperature_coefficient(self):
"""
Get cell temperature coefficient of PV module
:return: float
"""
return self._cell_temperature_coefficient
@property
def width(self):
"""
Get PV module width in m
:return: float
"""
return self._width
@property
def height(self):
"""
Get PV module height in m
:return: float
"""
return self._height
def to_dictionary(self):
"""Class content to dictionary"""
_distribution_systems = [_distribution_system.to_dictionary() for _distribution_system in
self.distribution_systems] if self.distribution_systems is not None else None
_energy_storage_systems = [_energy_storage_system.to_dictionary() for _energy_storage_system in
self.energy_storage_systems] if self.energy_storage_systems is not None else None
content = {
'Energy Generation component':
{
'id': self.id,
'model name': self.model_name,
'manufacturer': self.manufacturer,
'type': self.system_type,
'fuel type': self.fuel_type,
'electricity efficiency': self.electricity_efficiency,
'nominal power output [W]': self.nominal_electricity_output,
'nominal ambient temperature [Celsius]': self.nominal_ambient_temperature,
'nominal cell temperature [Celsius]': self.nominal_cell_temperature,
'nominal radiation [W/m2]': self.nominal_radiation,
'standard test condition cell temperature [Celsius]': self.standard_test_condition_cell_temperature,
'standard test condition maximum power [W]': self.standard_test_condition_maximum_power,
'standard test condition radiation [W/m2]': self.standard_test_condition_radiation,
'cell temperature coefficient': self.cell_temperature_coefficient,
'width': self.width,
'height': self.height,
'distribution systems connected': _distribution_systems,
'storage systems connected': _energy_storage_systems
}
}
return content

View File

@ -1,45 +1,36 @@
"""
Energy System catalog equipment
Energy Systems catalog System
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from typing import Union
from typing import Union, List
from pathlib import Path
from hub.catalog_factories.data_models.energy_systems.generation_system import GenerationSystem
from hub.catalog_factories.data_models.energy_systems.distribution_system import DistributionSystem
from hub.catalog_factories.data_models.energy_systems.emission_system import EmissionSystem
class System:
"""
System class
"""
def __init__(self,
lod,
system_id,
name,
demand_types,
generation_system,
distribution_system,
emission_system):
self._lod = lod
def __init__(self,
system_id,
demand_types,
name=None,
generation_systems=None,
distribution_systems=None,
configuration_schema=None):
self._system_id = system_id
self._name = name
self._demand_types = demand_types
self._generation_system = generation_system
self._distribution_system = distribution_system
self._emission_system = emission_system
@property
def lod(self):
"""
Get level of detail of the catalog
:return: string
"""
return self._lod
self._generation_systems = generation_systems
self._distribution_systems = distribution_systems
self._configuration_schema = configuration_schema
@property
def id(self):
@ -52,7 +43,7 @@ class System:
@property
def name(self):
"""
Get name
Get the system name
:return: string
"""
return self._name
@ -60,50 +51,49 @@ class System:
@property
def demand_types(self):
"""
Get demand able to cover from [heating, cooling, domestic_hot_water, electricity]
Get demand able to cover from ['heating', 'cooling', 'domestic_hot_water', 'electricity']
:return: [string]
"""
return self._demand_types
@property
def generation_system(self) -> GenerationSystem:
def generation_systems(self) -> Union[None, List[GenerationSystem]]:
"""
Get generation system
:return: GenerationSystem
Get generation systems
:return: [GenerationSystem]
"""
return self._generation_system
return self._generation_systems
@property
def distribution_system(self) -> Union[None, DistributionSystem]:
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
"""
Get distribution system
:return: DistributionSystem
Get distribution systems
:return: [DistributionSystem]
"""
return self._distribution_system
return self._distribution_systems
@property
def emission_system(self) -> Union[None, EmissionSystem]:
def configuration_schema(self) -> Path:
"""
Get emission system
:return: EmissionSystem
Get system configuration schema
:return: Path
"""
return self._emission_system
return self._configuration_schema
def to_dictionary(self):
"""Class content to dictionary"""
_distribution_system = None
if self.distribution_system is not None:
_distribution_system = self.distribution_system.to_dictionary()
_emission_system = None
if self.emission_system is not None:
_emission_system = self.emission_system.to_dictionary()
content = {'Layer': {'id': self.id,
'name': self.name,
'level of detail': self.lod,
'demand types': self.demand_types,
'generation system': self.generation_system.to_dictionary(),
'distribution system': _distribution_system,
'emission system': _emission_system
}
_generation_systems = []
for _generation in self.generation_systems:
_generation_systems.append(_generation.to_dictionary())
_distribution_systems = [_distribution.to_dictionary() for _distribution in
self.distribution_systems] if self.distribution_systems is not None else None
content = {'system': {'id': self.id,
'name': self.name,
'demand types': self.demand_types,
'generation system(s)': _generation_systems,
'distribution system(s)': _distribution_systems,
'configuration schema path': self.configuration_schema
}
}
return content

View File

@ -0,0 +1,126 @@
"""
Energy System catalog thermal storage system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from hub.catalog_factories.data_models.energy_systems.energy_storage_system import EnergyStorageSystem
from hub.catalog_factories.data_models.construction.layer import Layer
from hub.catalog_factories.data_models.construction.material import Material
class ThermalStorageSystem(EnergyStorageSystem):
""""
Energy Storage System Class
"""
def __init__(self, storage_id, type_energy_stored=None, model_name=None, manufacturer=None, storage_type=None,
nominal_capacity=None, losses_ratio=None, volume=None, height=None, layers=None,
maximum_operating_temperature=None, storage_medium=None, heating_coil_capacity=None):
super().__init__(storage_id, model_name, manufacturer, nominal_capacity, losses_ratio)
self._type_energy_stored = type_energy_stored
self._storage_type = storage_type
self._volume = volume
self._height = height
self._layers = layers
self._maximum_operating_temperature = maximum_operating_temperature
self._storage_medium = storage_medium
self._heating_coil_capacity = heating_coil_capacity
@property
def type_energy_stored(self):
"""
Get type of energy stored from ['electrical', 'thermal']
:return: string
"""
return self._type_energy_stored
@property
def storage_type(self):
"""
Get storage type from ['thermal', 'sensible', 'latent']
:return: string
"""
return self._storage_type
@property
def volume(self):
"""
Get the physical volume of the storage system in cubic meters
:return: float
"""
return self._volume
@property
def height(self):
"""
Get the diameter of the storage system in meters
:return: float
"""
return self._height
@property
def layers(self) -> [Layer]:
"""
Get construction layers
:return: [layer]
"""
return self._layers
@property
def maximum_operating_temperature(self):
"""
Get maximum operating temperature of the storage system in degree Celsius
:return: float
"""
return self._maximum_operating_temperature
@property
def storage_medium(self) -> Material:
"""
Get thermodynamic characteristics of the storage medium
:return: [material
"""
return self._storage_medium
@property
def heating_coil_capacity(self):
"""
Get heating coil capacity in Watts
:return: [material
"""
return self._heating_coil_capacity
def to_dictionary(self):
"""Class content to dictionary"""
_layers = None
_medias = None
if self.layers is not None:
_layers = []
for _layer in self.layers:
_layers.append(_layer.to_dictionary())
if self.storage_medium is not None:
_medias = self.storage_medium.to_dictionary()
content = {
'Storage component':
{
'storage id': self.id,
'type of energy stored': self.type_energy_stored,
'model name': self.model_name,
'manufacturer': self.manufacturer,
'storage type': self.storage_type,
'nominal capacity [J]': self.nominal_capacity,
'losses-ratio [J/J]': self.losses_ratio,
'volume [m3]': self.volume,
'height [m]': self.height,
'layers': _layers,
'maximum operating temperature [Celsius]': self.maximum_operating_temperature,
'storage_medium': _medias,
'heating coil capacity [W]': self.heating_coil_capacity
}
}
return content

View File

@ -1,76 +0,0 @@
"""
Stochastic_occupancy catalog Archetype
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Sanam Dabirian sanam.dabirian@mail.concordia.ca
"""
class Archetype:
"""
Archetype class
"""
def __init__(self, archetype_id,
name,
building_type,
building_subtype,
climate_zone
):
self._id = archetype_id
self._name = name
self._building_type = building_type
self._building_subtype = building_subtype
self._climate_zone = climate_zone
self._clusters = clusters
@property
def id(self):
"""
Get archetype id
:return: str
"""
return self._id
@property
def name(self):
"""
Get archetype name
:return: str
"""
return self._name
@property
def building_type(self):
"""
Get archetype type
:return: str
"""
return self._building_type
@property
def building_subtype(self):
"""
Get archetype type
:return: str
"""
return self._building_subtype
@property
def climate_zone(self):
"""
Get archetype climate zone
:return: str
"""
return self._climate_zone
def to_dictionary(self):
"""Class content to dictionary"""
_stochastic_schedule = []
content = {'Archetype': {'id': self.id,
'name': self.name,
'building_type': self.building_type,
'building_subtype': self.building_subtype,
'climate zone': self.climate_zone
}
}
return content

View File

@ -1,32 +0,0 @@
"""
Stochastic_occupancy catalog Clusters
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Sanam Dabirian sanam.dabirian@mail.concordia.ca
"""
from hub.catalog_factories.data_models.usages.schedule import Schedule
class Cluster:
"""
Clusters class
"""
def __init__(self, day_type,
schedules
):
self._day_type = day_type
self._schedules = schedules
@property
def day_type(self):
"""
Get type of day (Weekday or Weekend)
:return: str
"""
return self._day_type
@property
def schedules(self) -> [Schedule]:
return self._schedules

View File

@ -54,7 +54,7 @@ class Lighting:
return self._latent_fraction
@property
def schedules(self) -> Union[None, List[Schedule], List[Stochastic_Schedule]]:
def schedules(self) -> Union[None, List[Schedule]]:
"""
Get schedules
dataType = fraction

View File

@ -10,45 +10,46 @@ import xmltodict
from hub.catalog_factories.catalog import Catalog
from hub.catalog_factories.data_models.energy_systems.system import System
from hub.catalog_factories.data_models.energy_systems.content import Content
from hub.catalog_factories.data_models.energy_systems.generation_system import GenerationSystem
from hub.catalog_factories.data_models.energy_systems.non_pv_generation_system import NonPvGenerationSystem
from hub.catalog_factories.data_models.energy_systems.pv_generation_system import PvGenerationSystem
from hub.catalog_factories.data_models.energy_systems.distribution_system import DistributionSystem
from hub.catalog_factories.data_models.energy_systems.emission_system import EmissionSystem
from hub.catalog_factories.data_models.energy_systems.archetype import Archetype
from hub.catalog_factories.data_models.energy_systems.thermal_storage_system import ThermalStorageSystem
from hub.catalog_factories.data_models.energy_systems.electrical_storage_system import ElectricalStorageSystem
class MontrealCustomCatalog(Catalog):
"""
Montreal custom energy systems catalog class
"""
def __init__(self, path):
path = str(path / 'montreal_custom_systems.xml')
with open(path, 'r', encoding='utf-8') as xml:
self._archetypes = xmltodict.parse(xml.read(), force_list=('system', 'system_cluster', 'equipment',
'demand', 'system_id'))
self._lod = float(self._archetypes['catalog']['@lod'])
self._catalog_generation_equipments = self._load_generation_equipments()
self._catalog_distribution_equipments = self._load_distribution_equipments()
self._catalog_emission_equipments = self._load_emission_equipments()
self._catalog_distribution_equipments = self._load_distribution_equipments()
self._catalog_systems = self._load_systems()
self._catalog_archetypes = self._load_archetypes()
# store the full catalog data model in self._content
self._content = Content(self._catalog_archetypes,
self._catalog_systems,
self._catalog_generation_equipments,
self._catalog_distribution_equipments,
self._catalog_emission_equipments)
self._catalog_distribution_equipments)
def _load_generation_equipments(self):
_equipments = []
_storages = []
equipments = self._archetypes['catalog']['generation_equipments']['equipment']
for equipment in equipments:
equipment_id = float(equipment['@id'])
equipment_type = equipment['@type']
fuel_type = equipment['@fuel_type']
name = equipment['name']
model_name = equipment['name']
heating_efficiency = None
if 'heating_efficiency' in equipment:
heating_efficiency = float(equipment['heating_efficiency'])
@ -58,21 +59,38 @@ class MontrealCustomCatalog(Catalog):
electricity_efficiency = None
if 'electrical_efficiency' in equipment:
electricity_efficiency = float(equipment['electrical_efficiency'])
storage = literal_eval(equipment['storage'].capitalize())
generation_system = GenerationSystem(equipment_id,
name,
equipment_type,
fuel_type,
None,
heating_efficiency,
cooling_efficiency,
electricity_efficiency,
None,
None,
storage,
None)
storage_systems = None
storage = literal_eval(equipment['storage'].capitalize())
if storage:
if equipment_type == 'electricity generator':
storage_system = ElectricalStorageSystem(equipment_id)
else:
storage_system = ThermalStorageSystem(equipment_id)
storage_systems = [storage_system]
if model_name == 'PV system':
system_type = 'photovoltaic'
generation_system = PvGenerationSystem(equipment_id,
name=None,
system_type=system_type,
model_name=model_name,
electricity_efficiency=electricity_efficiency,
energy_storage_systems=storage_systems
)
else:
generation_system = NonPvGenerationSystem(equipment_id,
name=None,
model_name=model_name,
system_type=equipment_type,
fuel_type=fuel_type,
heat_efficiency=heating_efficiency,
cooling_efficiency=cooling_efficiency,
electricity_efficiency=electricity_efficiency,
energy_storage_systems=storage_systems,
domestic_hot_water=False
)
_equipments.append(generation_system)
return _equipments
def _load_distribution_equipments(self):
@ -81,7 +99,7 @@ class MontrealCustomCatalog(Catalog):
for equipment in equipments:
equipment_id = float(equipment['@id'])
equipment_type = equipment['@type']
name = equipment['name']
model_name = equipment['name']
distribution_heat_losses = None
if 'distribution_heat_losses' in equipment:
distribution_heat_losses = float(equipment['distribution_heat_losses']['#text']) / 100
@ -90,15 +108,22 @@ class MontrealCustomCatalog(Catalog):
distribution_consumption_fix_flow = float(equipment['distribution_consumption_fix_flow']['#text']) / 100
distribution_consumption_variable_flow = None
if 'distribution_consumption_variable_flow' in equipment:
distribution_consumption_variable_flow = float(equipment['distribution_consumption_variable_flow']['#text']) / 100
distribution_consumption_variable_flow = float(
equipment['distribution_consumption_variable_flow']['#text']) / 100
emission_equipment = equipment['dissipation_id']
_emission_equipments = None
for equipment_archetype in self._catalog_emission_equipments:
if int(equipment_archetype.id) == int(emission_equipment):
_emission_equipments = [equipment_archetype]
distribution_system = DistributionSystem(equipment_id,
name,
equipment_type,
None,
distribution_consumption_fix_flow,
distribution_consumption_variable_flow,
distribution_heat_losses)
model_name=model_name,
system_type=equipment_type,
distribution_consumption_fix_flow=distribution_consumption_fix_flow,
distribution_consumption_variable_flow=distribution_consumption_variable_flow,
heat_losses=distribution_heat_losses,
emission_systems=_emission_equipments)
_equipments.append(distribution_system)
return _equipments
@ -109,15 +134,15 @@ class MontrealCustomCatalog(Catalog):
for equipment in equipments:
equipment_id = float(equipment['@id'])
equipment_type = equipment['@type']
name = equipment['name']
parasitic_consumption = None
model_name = equipment['name']
parasitic_consumption = 0
if 'parasitic_consumption' in equipment:
parasitic_consumption = float(equipment['parasitic_consumption']['#text']) / 100
emission_system = EmissionSystem(equipment_id,
name,
equipment_type,
parasitic_consumption)
model_name=model_name,
system_type=equipment_type,
parasitic_energy_consumption=parasitic_consumption)
_equipments.append(emission_system)
return _equipments
@ -130,28 +155,21 @@ class MontrealCustomCatalog(Catalog):
name = system['name']
demands = system['demands']['demand']
generation_equipment = system['equipments']['generation_id']
_generation_equipment = None
_generation_equipments = None
for equipment_archetype in self._catalog_generation_equipments:
if int(equipment_archetype.id) == int(generation_equipment):
_generation_equipment = equipment_archetype
_generation_equipments = [equipment_archetype]
distribution_equipment = system['equipments']['distribution_id']
_distribution_equipment = None
_distribution_equipments = None
for equipment_archetype in self._catalog_distribution_equipments:
if int(equipment_archetype.id) == int(distribution_equipment):
_distribution_equipment = equipment_archetype
emission_equipment = system['equipments']['dissipation_id']
_emission_equipment = None
for equipment_archetype in self._catalog_emission_equipments:
if int(equipment_archetype.id) == int(emission_equipment):
_emission_equipment = equipment_archetype
_distribution_equipments = [equipment_archetype]
_catalog_systems.append(System(self._lod,
system_id,
name,
_catalog_systems.append(System(system_id,
demands,
_generation_equipment,
_distribution_equipment,
_emission_equipment))
name=name,
generation_systems=_generation_equipments,
distribution_systems=_distribution_equipments))
return _catalog_systems
def _load_archetypes(self):
@ -165,7 +183,7 @@ class MontrealCustomCatalog(Catalog):
for system_archetype in self._catalog_systems:
if int(system_archetype.id) == int(system):
_systems.append(system_archetype)
_catalog_archetypes.append(Archetype(self._lod, name, _systems))
_catalog_archetypes.append(Archetype(name, _systems))
return _catalog_archetypes
def names(self, category=None):
@ -175,17 +193,15 @@ class MontrealCustomCatalog(Catalog):
"""
if category is None:
_names = {'archetypes': [], 'systems': [], 'generation_equipments': [], 'distribution_equipments': [],
'emission_equipments':[]}
'emission_equipments': []}
for archetype in self._content.archetypes:
_names['archetypes'].append(archetype.name)
for system in self._content.systems:
_names['systems'].append(system.name)
for equipment in self._content.generation_equipments:
_names['generation_equipments'].append(equipment.name)
_names['generation_equipments'].append(equipment.model_name)
for equipment in self._content.distribution_equipments:
_names['distribution_equipments'].append(equipment.name)
for equipment in self._content.emission_equipments:
_names['emission_equipments'].append(equipment.name)
_names['distribution_equipments'].append(equipment.model_name)
else:
_names = {category: []}
if category.lower() == 'archetypes':
@ -196,13 +212,10 @@ class MontrealCustomCatalog(Catalog):
_names[category].append(system.name)
elif category.lower() == 'generation_equipments':
for system in self._content.generation_equipments:
_names[category].append(system.name)
_names[category].append(system.model_name)
elif category.lower() == 'distribution_equipments':
for system in self._content.distribution_equipments:
_names[category].append(system.name)
elif category.lower() == 'emission_equipments':
for system in self._content.emission_equipments:
_names[category].append(system.name)
_names[category].append(system.model_name)
else:
raise ValueError(f'Unknown category [{category}]')
return _names
@ -222,9 +235,6 @@ class MontrealCustomCatalog(Catalog):
return self._content.generation_equipments
if category.lower() == 'distribution_equipments':
return self._content.distribution_equipments
if category.lower() == 'emission_equipments':
return self._content.emission_equipments
raise ValueError(f'Unknown category [{category}]')
def get_entry(self, name):
"""
@ -238,12 +248,9 @@ class MontrealCustomCatalog(Catalog):
if entry.name.lower() == name.lower():
return entry
for entry in self._content.generation_equipments:
if entry.name.lower() == name.lower():
if entry.model_name.lower() == name.lower():
return entry
for entry in self._content.distribution_equipments:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.emission_equipments:
if entry.name.lower() == name.lower():
if entry.model_name.lower() == name.lower():
return entry
raise IndexError(f"{name} doesn't exists in the catalog")

View File

@ -0,0 +1,561 @@
"""
Montreal future energy system catalog
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
import xmltodict
from pathlib import Path
from hub.catalog_factories.catalog import Catalog
from hub.catalog_factories.data_models.energy_systems.distribution_system import DistributionSystem
from hub.catalog_factories.data_models.energy_systems.emission_system import EmissionSystem
from hub.catalog_factories.data_models.energy_systems.system import System
from hub.catalog_factories.data_models.energy_systems.content import Content
from hub.catalog_factories.data_models.energy_systems.non_pv_generation_system import NonPvGenerationSystem
from hub.catalog_factories.data_models.energy_systems.pv_generation_system import PvGenerationSystem
from hub.catalog_factories.data_models.energy_systems.thermal_storage_system import ThermalStorageSystem
from hub.catalog_factories.data_models.energy_systems.performance_curves import PerformanceCurves
from hub.catalog_factories.data_models.energy_systems.archetype import Archetype
from hub.catalog_factories.data_models.construction.material import Material
from hub.catalog_factories.data_models.construction.layer import Layer
class MontrealFutureSystemCatalogue(Catalog):
"""
North america energy system catalog class
"""
def __init__(self, path):
path = str(path / 'montreal_future_systems.xml')
with open(path, 'r', encoding='utf-8') as xml:
self._archetypes = xmltodict.parse(xml.read(),
force_list=['pv_generation_component', 'templateStorages', 'demand',
'system', 'system_id'])
self._storage_components = self._load_storage_components()
self._generation_components = self._load_generation_components()
self._energy_emission_components = self._load_emission_equipments()
self._distribution_components = self._load_distribution_equipments()
self._systems = self._load_systems()
self._system_archetypes = self._load_archetypes()
self._content = Content(self._system_archetypes,
self._systems,
generations=self._generation_components,
distributions=self._distribution_components)
def _load_generation_components(self):
generation_components = []
non_pv_generation_components = self._archetypes['EnergySystemCatalog']['energy_generation_components'][
'non_pv_generation_component']
if non_pv_generation_components is not None:
for non_pv in non_pv_generation_components:
system_id = non_pv['generation_system_id']
name = non_pv['name']
system_type = non_pv['system_type']
model_name = non_pv['model_name']
manufacturer = non_pv['manufacturer']
fuel_type = non_pv['fuel_type']
distribution_systems = non_pv['distribution_systems']
energy_storage_systems = None
if non_pv['energy_storage_systems'] is not None:
storage_component = non_pv['energy_storage_systems']['storage_id']
storage_systems = self._search_storage_equipment(self._load_storage_components(), storage_component)
energy_storage_systems = storage_systems
nominal_heat_output = non_pv['nominal_heat_output']
maximum_heat_output = non_pv['maximum_heat_output']
minimum_heat_output = non_pv['minimum_heat_output']
source_medium = non_pv['source_medium']
supply_medium = non_pv['supply_medium']
heat_efficiency = non_pv['heat_efficiency']
nominal_cooling_output = non_pv['nominal_cooling_output']
maximum_cooling_output = non_pv['maximum_cooling_output']
minimum_cooling_output = non_pv['minimum_cooling_output']
cooling_efficiency = non_pv['cooling_efficiency']
electricity_efficiency = non_pv['electricity_efficiency']
source_temperature = non_pv['source_temperature']
source_mass_flow = non_pv['source_mass_flow']
nominal_electricity_output = non_pv['nominal_electricity_output']
maximum_heat_supply_temperature = non_pv['maximum_heat_supply_temperature']
minimum_heat_supply_temperature = non_pv['minimum_heat_supply_temperature']
maximum_cooling_supply_temperature = non_pv['maximum_cooling_supply_temperature']
minimum_cooling_supply_temperature = non_pv['minimum_cooling_supply_temperature']
heat_output_curve = None
heat_fuel_consumption_curve = None
heat_efficiency_curve = None
cooling_output_curve = None
cooling_fuel_consumption_curve = None
cooling_efficiency_curve = None
if non_pv['heat_output_curve'] is not None:
curve_type = non_pv['heat_output_curve']['curve_type']
dependant_variable = non_pv['heat_output_curve']['dependant_variable']
parameters = non_pv['heat_output_curve']['parameters']
coefficients = list(non_pv['heat_output_curve']['coefficients'].values())
heat_output_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['heat_fuel_consumption_curve'] is not None:
curve_type = non_pv['heat_fuel_consumption_curve']['curve_type']
dependant_variable = non_pv['heat_fuel_consumption_curve']['dependant_variable']
parameters = non_pv['heat_fuel_consumption_curve']['parameters']
coefficients = list(non_pv['heat_fuel_consumption_curve']['coefficients'].values())
heat_fuel_consumption_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['heat_efficiency_curve'] is not None:
curve_type = non_pv['heat_efficiency_curve']['curve_type']
dependant_variable = non_pv['heat_efficiency_curve']['dependant_variable']
parameters = non_pv['heat_efficiency_curve']['parameters']
coefficients = list(non_pv['heat_efficiency_curve']['coefficients'].values())
heat_efficiency_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['cooling_output_curve'] is not None:
curve_type = non_pv['cooling_output_curve']['curve_type']
dependant_variable = non_pv['cooling_output_curve']['dependant_variable']
parameters = non_pv['cooling_output_curve']['parameters']
coefficients = list(non_pv['cooling_output_curve']['coefficients'].values())
cooling_output_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['cooling_fuel_consumption_curve'] is not None:
curve_type = non_pv['cooling_fuel_consumption_curve']['curve_type']
dependant_variable = non_pv['cooling_fuel_consumption_curve']['dependant_variable']
parameters = non_pv['cooling_fuel_consumption_curve']['parameters']
coefficients = list(non_pv['cooling_fuel_consumption_curve']['coefficients'].values())
cooling_fuel_consumption_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['cooling_efficiency_curve'] is not None:
curve_type = non_pv['cooling_efficiency_curve']['curve_type']
dependant_variable = non_pv['cooling_efficiency_curve']['dependant_variable']
parameters = non_pv['cooling_efficiency_curve']['parameters']
coefficients = list(non_pv['cooling_efficiency_curve']['coefficients'].values())
cooling_efficiency_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
dhw = None
if non_pv['domestic_hot_water'] is not None:
if non_pv['domestic_hot_water'] == 'True':
dhw = True
else:
dhw = False
reversible = None
if non_pv['reversible'] is not None:
if non_pv['reversible'] == 'True':
reversible = True
else:
reversible = False
dual_supply = None
if non_pv['simultaneous_heat_cold'] is not None:
if non_pv['simultaneous_heat_cold'] == 'True':
dual_supply = True
else:
dual_supply = False
non_pv_component = NonPvGenerationSystem(system_id=system_id,
name=name,
system_type=system_type,
model_name=model_name,
manufacturer=manufacturer,
fuel_type=fuel_type,
nominal_heat_output=nominal_heat_output,
maximum_heat_output=maximum_heat_output,
minimum_heat_output=minimum_heat_output,
source_medium=source_medium,
supply_medium=supply_medium,
heat_efficiency=heat_efficiency,
nominal_cooling_output=nominal_cooling_output,
maximum_cooling_output=maximum_cooling_output,
minimum_cooling_output=minimum_cooling_output,
cooling_efficiency=cooling_efficiency,
electricity_efficiency=electricity_efficiency,
source_temperature=source_temperature,
source_mass_flow=source_mass_flow,
nominal_electricity_output=nominal_electricity_output,
maximum_heat_supply_temperature=maximum_heat_supply_temperature,
minimum_heat_supply_temperature=minimum_heat_supply_temperature,
maximum_cooling_supply_temperature=maximum_cooling_supply_temperature,
minimum_cooling_supply_temperature=minimum_cooling_supply_temperature,
heat_output_curve=heat_output_curve,
heat_fuel_consumption_curve=heat_fuel_consumption_curve,
heat_efficiency_curve=heat_efficiency_curve,
cooling_output_curve=cooling_output_curve,
cooling_fuel_consumption_curve=cooling_fuel_consumption_curve,
cooling_efficiency_curve=cooling_efficiency_curve,
distribution_systems=distribution_systems,
energy_storage_systems=energy_storage_systems,
domestic_hot_water=dhw,
reversible=reversible,
simultaneous_heat_cold=dual_supply)
generation_components.append(non_pv_component)
pv_generation_components = self._archetypes['EnergySystemCatalog']['energy_generation_components'][
'pv_generation_component']
if pv_generation_components is not None:
for pv in pv_generation_components:
system_id = pv['generation_system_id']
name = pv['name']
system_type = pv['system_type']
model_name = pv['model_name']
manufacturer = pv['manufacturer']
electricity_efficiency = pv['electricity_efficiency']
nominal_electricity_output = pv['nominal_electricity_output']
nominal_ambient_temperature = pv['nominal_ambient_temperature']
nominal_cell_temperature = pv['nominal_cell_temperature']
nominal_radiation = pv['nominal_radiation']
standard_test_condition_cell_temperature = pv['standard_test_condition_cell_temperature']
standard_test_condition_maximum_power = pv['standard_test_condition_maximum_power']
standard_test_condition_radiation = pv['standard_test_condition_radiation']
cell_temperature_coefficient = pv['cell_temperature_coefficient']
width = pv['width']
height = pv['height']
distribution_systems = pv['distribution_systems']
energy_storage_systems = None
if pv['energy_storage_systems'] is not None:
storage_component = pv['energy_storage_systems']['storage_id']
storage_systems = self._search_storage_equipment(self._load_storage_components(), storage_component)
energy_storage_systems = storage_systems
pv_component = PvGenerationSystem(system_id=system_id,
name=name,
system_type=system_type,
model_name=model_name,
manufacturer=manufacturer,
electricity_efficiency=electricity_efficiency,
nominal_electricity_output=nominal_electricity_output,
nominal_ambient_temperature=nominal_ambient_temperature,
nominal_cell_temperature=nominal_cell_temperature,
nominal_radiation=nominal_radiation,
standard_test_condition_cell_temperature=
standard_test_condition_cell_temperature,
standard_test_condition_maximum_power=standard_test_condition_maximum_power,
standard_test_condition_radiation=standard_test_condition_radiation,
cell_temperature_coefficient=cell_temperature_coefficient,
width=width,
height=height,
distribution_systems=distribution_systems,
energy_storage_systems=energy_storage_systems)
generation_components.append(pv_component)
return generation_components
def _load_distribution_equipments(self):
_equipments = []
distribution_systems = self._archetypes['EnergySystemCatalog']['distribution_systems']['distribution_system']
if distribution_systems is not None:
for distribution_system in distribution_systems:
system_id = None
model_name = None
system_type = None
supply_temperature = None
distribution_consumption_fix_flow = None
distribution_consumption_variable_flow = None
heat_losses = None
generation_systems = None
energy_storage_systems = None
emission_systems = None
distribution_equipment = DistributionSystem(system_id=system_id,
model_name=model_name,
system_type=system_type,
supply_temperature=supply_temperature,
distribution_consumption_fix_flow=distribution_consumption_fix_flow,
distribution_consumption_variable_flow=
distribution_consumption_variable_flow,
heat_losses=heat_losses,
generation_systems=generation_systems,
energy_storage_systems=energy_storage_systems,
emission_systems=emission_systems
)
_equipments.append(distribution_equipment)
return _equipments
def _load_emission_equipments(self):
_equipments = []
dissipation_systems = self._archetypes['EnergySystemCatalog']['dissipation_systems']['dissipation_system']
if dissipation_systems is not None:
for dissipation_system in dissipation_systems:
system_id = None
model_name = None
system_type = None
parasitic_energy_consumption = 0
emission_system = EmissionSystem(system_id=system_id,
model_name=model_name,
system_type=system_type,
parasitic_energy_consumption=parasitic_energy_consumption)
_equipments.append(emission_system)
return _equipments
def _load_storage_components(self):
storage_components = []
thermal_storages = self._archetypes['EnergySystemCatalog']['energy_storage_components']['thermalStorages']
template_storages = self._archetypes['EnergySystemCatalog']['energy_storage_components']['templateStorages']
for tes in thermal_storages:
storage_id = tes['storage_id']
type_energy_stored = tes['type_energy_stored']
model_name = tes['model_name']
manufacturer = tes['manufacturer']
storage_type = tes['storage_type']
volume = tes['physical_characteristics']['volume']
height = tes['physical_characteristics']['height']
maximum_operating_temperature = tes['maximum_operating_temperature']
materials = self._load_materials()
insulation_material_id = tes['insulation']['material_id']
insulation_material = self._search_material(materials, insulation_material_id)
material_id = tes['physical_characteristics']['material_id']
tank_material = self._search_material(materials, material_id)
thickness = float(tes['insulation']['insulationThickness']) / 100 # from cm to m
insulation_layer = Layer(None, 'insulation', insulation_material, thickness)
thickness = float(tes['physical_characteristics']['tankThickness']) / 100 # from cm to m
tank_layer = Layer(None, 'tank', tank_material, thickness)
media = self._load_media()
media_id = tes['storage_medium']['medium_id']
medium = self._search_media(media, media_id)
layers = [insulation_layer, tank_layer]
nominal_capacity = tes['nominal_capacity']
losses_ratio = tes['losses_ratio']
heating_coil_capacity = tes['heating_coil_capacity']
storage_component = ThermalStorageSystem(storage_id=storage_id,
model_name=model_name,
type_energy_stored=type_energy_stored,
manufacturer=manufacturer,
storage_type=storage_type,
nominal_capacity=nominal_capacity,
losses_ratio=losses_ratio,
volume=volume,
height=height,
layers=layers,
maximum_operating_temperature=maximum_operating_temperature,
storage_medium=medium,
heating_coil_capacity=heating_coil_capacity)
storage_components.append(storage_component)
for template in template_storages:
storage_id = template['storage_id']
storage_type = template['storage_type']
type_energy_stored = template['type_energy_stored']
maximum_operating_temperature = template['maximum_operating_temperature']
height = float(template['physical_characteristics']['height'])
materials = self._load_materials()
insulation_material_id = template['insulation']['material_id']
insulation_material = self._search_material(materials, insulation_material_id)
material_id = template['physical_characteristics']['material_id']
tank_material = self._search_material(materials, material_id)
thickness = float(template['insulation']['insulationThickness']) / 100 # from cm to m
insulation_layer = Layer(None, 'insulation', insulation_material, thickness)
thickness = float(template['physical_characteristics']['tankThickness']) / 100 # from cm to m
tank_layer = Layer(None, 'tank', tank_material, thickness)
layers = [insulation_layer, tank_layer]
media = self._load_media()
media_id = template['storage_medium']['medium_id']
medium = self._search_media(media, media_id)
model_name = template['model_name']
manufacturer = template['manufacturer']
nominal_capacity = template['nominal_capacity']
losses_ratio = template['losses_ratio']
volume = template['physical_characteristics']['volume']
heating_coil_capacity = template['heating_coil_capacity']
storage_component = ThermalStorageSystem(storage_id=storage_id,
model_name=model_name,
type_energy_stored=type_energy_stored,
manufacturer=manufacturer,
storage_type=storage_type,
nominal_capacity=nominal_capacity,
losses_ratio=losses_ratio,
volume=volume,
height=height,
layers=layers,
maximum_operating_temperature=maximum_operating_temperature,
storage_medium=medium,
heating_coil_capacity=heating_coil_capacity)
storage_components.append(storage_component)
return storage_components
def _load_systems(self):
base_path = Path(Path(__file__).parent.parent.parent / 'data/energy_systems')
_catalog_systems = []
systems = self._archetypes['EnergySystemCatalog']['systems']['system']
for system in systems:
system_id = system['id']
name = system['name']
demands = system['demands']['demand']
generation_components = system['components']['generation_id']
generation_systems = self._search_generation_equipment(self._load_generation_components(), generation_components)
configuration_schema = Path(base_path / system['schema'])
energy_system = System(system_id=system_id,
name=name,
demand_types=demands,
generation_systems=generation_systems,
distribution_systems=None,
configuration_schema=configuration_schema)
_catalog_systems.append(energy_system)
return _catalog_systems
def _load_archetypes(self):
_system_archetypes = []
system_clusters = self._archetypes['EnergySystemCatalog']['system_archetypes']['system_archetype']
for system_cluster in system_clusters:
archetype_id = system_cluster['@cluster_id']
name = system_cluster['name']
systems = system_cluster['systems']['system_id']
integer_system_ids = [int(item) for item in systems]
_systems = []
for system_archetype in self._systems:
if int(system_archetype.id) in integer_system_ids:
_systems.append(system_archetype)
_system_archetypes.append(Archetype(archetype_cluster_id=archetype_id, name=name, systems=_systems))
return _system_archetypes
def _load_materials(self):
materials = []
_materials = self._archetypes['EnergySystemCatalog']['materials']['material']
for _material in _materials:
material_id = _material['material_id']
name = _material['name']
conductivity = _material['conductivity']
solar_absorptance = _material['solar_absorptance']
thermal_absorptance = _material['thermal_absorptance']
density = _material['density']
specific_heat = _material['specific_heat']
no_mass = _material['no_mass']
visible_absorptance = _material['visible_absorptance']
thermal_resistance = _material['thermal_resistance']
material = Material(material_id,
name,
solar_absorptance=solar_absorptance,
thermal_absorptance=thermal_absorptance,
density=density,
conductivity=conductivity,
thermal_resistance=thermal_resistance,
visible_absorptance=visible_absorptance,
no_mass=no_mass,
specific_heat=specific_heat)
materials.append(material)
return materials
@staticmethod
def _search_material(materials, material_id):
_material = None
for material in materials:
if int(material.id) == int(material_id):
_material = material
break
if _material is None:
raise ValueError(f'Material with the id = [{material_id}] not found in catalog ')
return _material
def _load_media(self):
media = []
_media = [self._archetypes['EnergySystemCatalog']['media']['medium']]
for _medium in _media:
medium_id = _medium['medium_id']
density = _medium['density']
name = _medium['name']
conductivity = _medium['conductivity']
solar_absorptance = _medium['solar_absorptance']
thermal_absorptance = _medium['thermal_absorptance']
specific_heat = _medium['specific_heat']
no_mass = _medium['no_mass']
visible_absorptance = _medium['visible_absorptance']
thermal_resistance = _medium['thermal_resistance']
medium = Material(material_id=medium_id,
name=name,
solar_absorptance=solar_absorptance,
thermal_absorptance=thermal_absorptance,
visible_absorptance=visible_absorptance,
no_mass=no_mass,
thermal_resistance=thermal_resistance,
conductivity=conductivity,
density=density,
specific_heat=specific_heat)
media.append(medium)
return media
@staticmethod
def _search_media(media, medium_id):
_medium = None
for medium in media:
if int(medium.id) == int(medium_id):
_medium = medium
break
if _medium is None:
raise ValueError(f'media with the id = [{medium_id}] not found in catalog ')
return _medium
@staticmethod
def _search_generation_equipment(generation_systems, generation_id):
_generation_systems = []
if isinstance(generation_id, list):
integer_ids = [int(item) for item in generation_id]
for generation in generation_systems:
if int(generation.id) in integer_ids:
_generation_systems.append(generation)
else:
integer_id = int(generation_id)
for generation in generation_systems:
if int(generation.id) == integer_id:
_generation_systems.append(generation)
if len(_generation_systems) == 0:
_generation_systems = None
raise ValueError(f'The system with the following id is not found in catalog [{generation_id}]')
return _generation_systems
@staticmethod
def _search_storage_equipment(storage_systems, storage_id):
_storage_systems = []
for storage in storage_systems:
if storage.id in storage_id:
_storage_systems.append(storage)
if len(_storage_systems) == 0:
_storage_systems = None
raise ValueError(f'The system with the following id is not found in catalog [{storage_id}]')
return _storage_systems
def names(self, category=None):
"""
Get the catalog elements names
:parm: optional category filter
"""
if category is None:
_names = {'archetypes': [], 'systems': [], 'generation_equipments': [], 'storage_equipments': []}
for archetype in self._content.archetypes:
_names['archetypes'].append(archetype.name)
for system in self._content.systems:
_names['systems'].append(system.name)
for equipment in self._content.generation_equipments:
_names['generation_equipments'].append(equipment.name)
else:
_names = {category: []}
if category.lower() == 'archetypes':
for archetype in self._content.archetypes:
_names[category].append(archetype.name)
elif category.lower() == 'systems':
for system in self._content.systems:
_names[category].append(system.name)
elif category.lower() == 'generation_equipments':
for system in self._content.generation_equipments:
_names[category].append(system.name)
else:
raise ValueError(f'Unknown category [{category}]')
return _names
def entries(self, category=None):
"""
Get the catalog elements
:parm: optional category filter
"""
if category is None:
return self._content
if category.lower() == 'archetypes':
return self._content.archetypes
if category.lower() == 'systems':
return self._content.systems
if category.lower() == 'generation_equipments':
return self._content.generation_equipments
raise ValueError(f'Unknown category [{category}]')
def get_entry(self, name):
"""
Get one catalog element by names
:parm: entry name
"""
for entry in self._content.archetypes:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.systems:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.generation_equipments:
if entry.name.lower() == name.lower():
return entry
raise IndexError(f"{name} doesn't exists in the catalog")

View File

@ -0,0 +1,520 @@
"""
Palma energy system catalog
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
import xmltodict
from pathlib import Path
from hub.catalog_factories.catalog import Catalog
from hub.catalog_factories.data_models.energy_systems.distribution_system import DistributionSystem
from hub.catalog_factories.data_models.energy_systems.emission_system import EmissionSystem
from hub.catalog_factories.data_models.energy_systems.system import System
from hub.catalog_factories.data_models.energy_systems.content import Content
from hub.catalog_factories.data_models.energy_systems.non_pv_generation_system import NonPvGenerationSystem
from hub.catalog_factories.data_models.energy_systems.pv_generation_system import PvGenerationSystem
from hub.catalog_factories.data_models.energy_systems.thermal_storage_system import ThermalStorageSystem
from hub.catalog_factories.data_models.energy_systems.performance_curves import PerformanceCurves
from hub.catalog_factories.data_models.energy_systems.archetype import Archetype
from hub.catalog_factories.data_models.construction.material import Material
from hub.catalog_factories.data_models.construction.layer import Layer
class PalmaSystemCatalogue(Catalog):
"""
North america energy system catalog class
"""
def __init__(self, path):
path = str(path / 'palma_systems.xml')
with open(path, 'r', encoding='utf-8') as xml:
self._archetypes = xmltodict.parse(xml.read(),
force_list=['pv_generation_component', 'demand'])
self._storage_components = self._load_storage_components()
self._generation_components = self._load_generation_components()
self._energy_emission_components = self._load_emission_equipments()
self._distribution_components = self._load_distribution_equipments()
self._systems = self._load_systems()
self._system_archetypes = self._load_archetypes()
self._content = Content(self._system_archetypes,
self._systems,
generations=self._generation_components,
distributions=self._distribution_components)
def _load_generation_components(self):
generation_components = []
non_pv_generation_components = self._archetypes['EnergySystemCatalog']['energy_generation_components'][
'non_pv_generation_component']
if non_pv_generation_components is not None:
for non_pv in non_pv_generation_components:
system_id = non_pv['system_id']
name = non_pv['name']
system_type = non_pv['system_type']
model_name = non_pv['model_name']
manufacturer = non_pv['manufacturer']
fuel_type = non_pv['fuel_type']
distribution_systems = non_pv['distribution_systems']
energy_storage_systems = None
if non_pv['energy_storage_systems'] is not None:
storage_component = non_pv['energy_storage_systems']['storage_id']
storage_systems = self._search_storage_equipment(self._load_storage_components(), storage_component)
energy_storage_systems = storage_systems
nominal_heat_output = non_pv['nominal_heat_output']
maximum_heat_output = non_pv['maximum_heat_output']
minimum_heat_output = non_pv['minimum_heat_output']
source_medium = non_pv['source_medium']
supply_medium = non_pv['supply_medium']
heat_efficiency = non_pv['heat_efficiency']
nominal_cooling_output = non_pv['nominal_cooling_output']
maximum_cooling_output = non_pv['maximum_cooling_output']
minimum_cooling_output = non_pv['minimum_cooling_output']
cooling_efficiency = non_pv['cooling_efficiency']
electricity_efficiency = non_pv['electricity_efficiency']
source_temperature = non_pv['source_temperature']
source_mass_flow = non_pv['source_mass_flow']
nominal_electricity_output = non_pv['nominal_electricity_output']
maximum_heat_supply_temperature = non_pv['maximum_heat_supply_temperature']
minimum_heat_supply_temperature = non_pv['minimum_heat_supply_temperature']
maximum_cooling_supply_temperature = non_pv['maximum_cooling_supply_temperature']
minimum_cooling_supply_temperature = non_pv['minimum_cooling_supply_temperature']
heat_output_curve = None
heat_fuel_consumption_curve = None
heat_efficiency_curve = None
cooling_output_curve = None
cooling_fuel_consumption_curve = None
cooling_efficiency_curve = None
if non_pv['heat_output_curve'] is not None:
curve_type = non_pv['heat_output_curve']['curve_type']
dependant_variable = non_pv['heat_output_curve']['dependant_variable']
parameters = non_pv['heat_output_curve']['parameters']
coefficients = list(non_pv['heat_output_curve']['coefficients'].values())
heat_output_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['heat_fuel_consumption_curve'] is not None:
curve_type = non_pv['heat_fuel_consumption_curve']['curve_type']
dependant_variable = non_pv['heat_fuel_consumption_curve']['dependant_variable']
parameters = non_pv['heat_fuel_consumption_curve']['parameters']
coefficients = list(non_pv['heat_fuel_consumption_curve']['coefficients'].values())
heat_fuel_consumption_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['heat_efficiency_curve'] is not None:
curve_type = non_pv['heat_efficiency_curve']['curve_type']
dependant_variable = non_pv['heat_efficiency_curve']['dependant_variable']
parameters = non_pv['heat_efficiency_curve']['parameters']
coefficients = list(non_pv['heat_efficiency_curve']['coefficients'].values())
heat_efficiency_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['cooling_output_curve'] is not None:
curve_type = non_pv['cooling_output_curve']['curve_type']
dependant_variable = non_pv['cooling_output_curve']['dependant_variable']
parameters = non_pv['cooling_output_curve']['parameters']
coefficients = list(non_pv['cooling_output_curve']['coefficients'].values())
cooling_output_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['cooling_fuel_consumption_curve'] is not None:
curve_type = non_pv['cooling_fuel_consumption_curve']['curve_type']
dependant_variable = non_pv['cooling_fuel_consumption_curve']['dependant_variable']
parameters = non_pv['cooling_fuel_consumption_curve']['parameters']
coefficients = list(non_pv['cooling_fuel_consumption_curve']['coefficients'].values())
cooling_fuel_consumption_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
if non_pv['cooling_efficiency_curve'] is not None:
curve_type = non_pv['cooling_efficiency_curve']['curve_type']
dependant_variable = non_pv['cooling_efficiency_curve']['dependant_variable']
parameters = non_pv['cooling_efficiency_curve']['parameters']
coefficients = list(non_pv['cooling_efficiency_curve']['coefficients'].values())
cooling_efficiency_curve = PerformanceCurves(curve_type, dependant_variable, parameters, coefficients)
dhw = None
if non_pv['domestic_hot_water'] is not None:
if non_pv['domestic_hot_water'] == 'True':
dhw = True
else:
dhw = False
reversible = None
if non_pv['reversible'] is not None:
if non_pv['reversible'] == 'True':
reversible = True
else:
reversible = False
dual_supply = None
if non_pv['simultaneous_heat_cold'] is not None:
if non_pv['simultaneous_heat_cold'] == 'True':
dual_supply = True
else:
dual_supply = False
non_pv_component = NonPvGenerationSystem(system_id=system_id,
name=name,
system_type=system_type,
model_name=model_name,
manufacturer=manufacturer,
fuel_type=fuel_type,
nominal_heat_output=nominal_heat_output,
maximum_heat_output=maximum_heat_output,
minimum_heat_output=minimum_heat_output,
source_medium=source_medium,
supply_medium=supply_medium,
heat_efficiency=heat_efficiency,
nominal_cooling_output=nominal_cooling_output,
maximum_cooling_output=maximum_cooling_output,
minimum_cooling_output=minimum_cooling_output,
cooling_efficiency=cooling_efficiency,
electricity_efficiency=electricity_efficiency,
source_temperature=source_temperature,
source_mass_flow=source_mass_flow,
nominal_electricity_output=nominal_electricity_output,
maximum_heat_supply_temperature=maximum_heat_supply_temperature,
minimum_heat_supply_temperature=minimum_heat_supply_temperature,
maximum_cooling_supply_temperature=maximum_cooling_supply_temperature,
minimum_cooling_supply_temperature=minimum_cooling_supply_temperature,
heat_output_curve=heat_output_curve,
heat_fuel_consumption_curve=heat_fuel_consumption_curve,
heat_efficiency_curve=heat_efficiency_curve,
cooling_output_curve=cooling_output_curve,
cooling_fuel_consumption_curve=cooling_fuel_consumption_curve,
cooling_efficiency_curve=cooling_efficiency_curve,
distribution_systems=distribution_systems,
energy_storage_systems=energy_storage_systems,
domestic_hot_water=dhw,
reversible=reversible,
simultaneous_heat_cold=dual_supply)
generation_components.append(non_pv_component)
pv_generation_components = self._archetypes['EnergySystemCatalog']['energy_generation_components'][
'pv_generation_component']
if pv_generation_components is not None:
for pv in pv_generation_components:
system_id = pv['system_id']
name = pv['name']
system_type = pv['system_type']
model_name = pv['model_name']
manufacturer = pv['manufacturer']
electricity_efficiency = pv['electricity_efficiency']
nominal_electricity_output = pv['nominal_electricity_output']
nominal_ambient_temperature = pv['nominal_ambient_temperature']
nominal_cell_temperature = pv['nominal_cell_temperature']
nominal_radiation = pv['nominal_radiation']
standard_test_condition_cell_temperature = pv['standard_test_condition_cell_temperature']
standard_test_condition_maximum_power = pv['standard_test_condition_maximum_power']
standard_test_condition_radiation = pv['standard_test_condition_radiation']
cell_temperature_coefficient = pv['cell_temperature_coefficient']
width = pv['width']
height = pv['height']
distribution_systems = pv['distribution_systems']
energy_storage_systems = None
if pv['energy_storage_systems'] is not None:
storage_component = pv['energy_storage_systems']['storage_id']
storage_systems = self._search_storage_equipment(self._load_storage_components(), storage_component)
energy_storage_systems = storage_systems
pv_component = PvGenerationSystem(system_id=system_id,
name=name,
system_type=system_type,
model_name=model_name,
manufacturer=manufacturer,
electricity_efficiency=electricity_efficiency,
nominal_electricity_output=nominal_electricity_output,
nominal_ambient_temperature=nominal_ambient_temperature,
nominal_cell_temperature=nominal_cell_temperature,
nominal_radiation=nominal_radiation,
standard_test_condition_cell_temperature=
standard_test_condition_cell_temperature,
standard_test_condition_maximum_power=standard_test_condition_maximum_power,
standard_test_condition_radiation=standard_test_condition_radiation,
cell_temperature_coefficient=cell_temperature_coefficient,
width=width,
height=height,
distribution_systems=distribution_systems,
energy_storage_systems=energy_storage_systems)
generation_components.append(pv_component)
return generation_components
def _load_distribution_equipments(self):
_equipments = []
distribution_systems = self._archetypes['EnergySystemCatalog']['distribution_systems']['distribution_system']
if distribution_systems is not None:
for distribution_system in distribution_systems:
system_id = None
model_name = None
system_type = None
supply_temperature = None
distribution_consumption_fix_flow = None
distribution_consumption_variable_flow = None
heat_losses = None
generation_systems = None
energy_storage_systems = None
emission_systems = None
distribution_equipment = DistributionSystem(system_id=system_id,
model_name=model_name,
system_type=system_type,
supply_temperature=supply_temperature,
distribution_consumption_fix_flow=distribution_consumption_fix_flow,
distribution_consumption_variable_flow=
distribution_consumption_variable_flow,
heat_losses=heat_losses,
generation_systems=generation_systems,
energy_storage_systems=energy_storage_systems,
emission_systems=emission_systems
)
_equipments.append(distribution_equipment)
return _equipments
def _load_emission_equipments(self):
_equipments = []
dissipation_systems = self._archetypes['EnergySystemCatalog']['dissipation_systems']['dissipation_system']
if dissipation_systems is not None:
for dissipation_system in dissipation_systems:
system_id = None
model_name = None
system_type = None
parasitic_energy_consumption = 0
emission_system = EmissionSystem(system_id=system_id,
model_name=model_name,
system_type=system_type,
parasitic_energy_consumption=parasitic_energy_consumption)
_equipments.append(emission_system)
return _equipments
def _load_storage_components(self):
storage_components = []
thermal_storages = self._archetypes['EnergySystemCatalog']['energy_storage_components']['thermalStorages']
for tes in thermal_storages:
storage_id = tes['storage_id']
type_energy_stored = tes['type_energy_stored']
model_name = tes['model_name']
manufacturer = tes['manufacturer']
storage_type = tes['storage_type']
volume = tes['physical_characteristics']['volume']
height = tes['physical_characteristics']['height']
maximum_operating_temperature = tes['maximum_operating_temperature']
materials = self._load_materials()
insulation_material_id = tes['insulation']['material_id']
insulation_material = self._search_material(materials, insulation_material_id)
material_id = tes['physical_characteristics']['material_id']
tank_material = self._search_material(materials, material_id)
thickness = float(tes['insulation']['insulationThickness']) / 100 # from cm to m
insulation_layer = Layer(None, 'insulation', insulation_material, thickness)
thickness = float(tes['physical_characteristics']['tankThickness']) / 100 # from cm to m
tank_layer = Layer(None, 'tank', tank_material, thickness)
media = self._load_media()
media_id = tes['storage_medium']['medium_id']
medium = self._search_media(media, media_id)
layers = [insulation_layer, tank_layer]
nominal_capacity = tes['nominal_capacity']
losses_ratio = tes['losses_ratio']
heating_coil_capacity = tes['heating_coil_capacity']
storage_component = ThermalStorageSystem(storage_id=storage_id,
model_name=model_name,
type_energy_stored=type_energy_stored,
manufacturer=manufacturer,
storage_type=storage_type,
nominal_capacity=nominal_capacity,
losses_ratio=losses_ratio,
volume=volume,
height=height,
layers=layers,
maximum_operating_temperature=maximum_operating_temperature,
storage_medium=medium,
heating_coil_capacity=heating_coil_capacity)
storage_components.append(storage_component)
return storage_components
def _load_systems(self):
base_path = Path(Path(__file__).parent.parent.parent / 'data/energy_systems')
_catalog_systems = []
systems = self._archetypes['EnergySystemCatalog']['systems']['system']
for system in systems:
system_id = system['id']
name = system['name']
demands = system['demands']['demand']
generation_components = system['components']['generation_id']
generation_systems = self._search_generation_equipment(self._load_generation_components(), generation_components)
configuration_schema = None
if system['schema'] is not None:
configuration_schema = Path(base_path / system['schema'])
energy_system = System(system_id=system_id,
name=name,
demand_types=demands,
generation_systems=generation_systems,
distribution_systems=None,
configuration_schema=configuration_schema)
_catalog_systems.append(energy_system)
return _catalog_systems
def _load_archetypes(self):
_system_archetypes = []
system_clusters = self._archetypes['EnergySystemCatalog']['system_archetypes']['system_archetype']
for system_cluster in system_clusters:
name = system_cluster['name']
systems = system_cluster['systems']['system_id']
integer_system_ids = [int(item) for item in systems]
_systems = []
for system_archetype in self._systems:
if int(system_archetype.id) in integer_system_ids:
_systems.append(system_archetype)
_system_archetypes.append(Archetype(name=name, systems=_systems))
return _system_archetypes
def _load_materials(self):
materials = []
_materials = self._archetypes['EnergySystemCatalog']['materials']['material']
for _material in _materials:
material_id = _material['material_id']
name = _material['name']
conductivity = _material['conductivity']
solar_absorptance = _material['solar_absorptance']
thermal_absorptance = _material['thermal_absorptance']
density = _material['density']
specific_heat = _material['specific_heat']
no_mass = _material['no_mass']
visible_absorptance = _material['visible_absorptance']
thermal_resistance = _material['thermal_resistance']
material = Material(material_id,
name,
solar_absorptance=solar_absorptance,
thermal_absorptance=thermal_absorptance,
density=density,
conductivity=conductivity,
thermal_resistance=thermal_resistance,
visible_absorptance=visible_absorptance,
no_mass=no_mass,
specific_heat=specific_heat)
materials.append(material)
return materials
@staticmethod
def _search_material(materials, material_id):
_material = None
for material in materials:
if int(material.id) == int(material_id):
_material = material
break
if _material is None:
raise ValueError(f'Material with the id = [{material_id}] not found in catalog ')
return _material
def _load_media(self):
media = []
_media = [self._archetypes['EnergySystemCatalog']['media']['medium']]
for _medium in _media:
medium_id = _medium['medium_id']
density = _medium['density']
name = _medium['name']
conductivity = _medium['conductivity']
solar_absorptance = _medium['solar_absorptance']
thermal_absorptance = _medium['thermal_absorptance']
specific_heat = _medium['specific_heat']
no_mass = _medium['no_mass']
visible_absorptance = _medium['visible_absorptance']
thermal_resistance = _medium['thermal_resistance']
medium = Material(material_id=medium_id,
name=name,
solar_absorptance=solar_absorptance,
thermal_absorptance=thermal_absorptance,
visible_absorptance=visible_absorptance,
no_mass=no_mass,
thermal_resistance=thermal_resistance,
conductivity=conductivity,
density=density,
specific_heat=specific_heat)
media.append(medium)
return media
@staticmethod
def _search_media(media, medium_id):
_medium = None
for medium in media:
if int(medium.id) == int(medium_id):
_medium = medium
break
if _medium is None:
raise ValueError(f'media with the id = [{medium_id}] not found in catalog ')
return _medium
@staticmethod
def _search_generation_equipment(generation_systems, generation_id):
_generation_systems = []
if isinstance(generation_id, list):
integer_ids = [int(item) for item in generation_id]
for generation in generation_systems:
if int(generation.id) in integer_ids:
_generation_systems.append(generation)
else:
integer_id = int(generation_id)
for generation in generation_systems:
if int(generation.id) == integer_id:
_generation_systems.append(generation)
if len(_generation_systems) == 0:
_generation_systems = None
raise ValueError(f'The system with the following id is not found in catalog [{generation_id}]')
return _generation_systems
@staticmethod
def _search_storage_equipment(storage_systems, storage_id):
_storage_systems = []
for storage in storage_systems:
if storage.id in storage_id:
_storage_systems.append(storage)
if len(_storage_systems) == 0:
_storage_systems = None
raise ValueError(f'The system with the following id is not found in catalog [{storage_id}]')
return _storage_systems
def names(self, category=None):
"""
Get the catalog elements names
:parm: optional category filter
"""
if category is None:
_names = {'archetypes': [], 'systems': [], 'generation_equipments': [], 'storage_equipments': []}
for archetype in self._content.archetypes:
_names['archetypes'].append(archetype.name)
for system in self._content.systems:
_names['systems'].append(system.name)
for equipment in self._content.generation_equipments:
_names['generation_equipments'].append(equipment.name)
else:
_names = {category: []}
if category.lower() == 'archetypes':
for archetype in self._content.archetypes:
_names[category].append(archetype.name)
elif category.lower() == 'systems':
for system in self._content.systems:
_names[category].append(system.name)
elif category.lower() == 'generation_equipments':
for system in self._content.generation_equipments:
_names[category].append(system.name)
else:
raise ValueError(f'Unknown category [{category}]')
return _names
def entries(self, category=None):
"""
Get the catalog elements
:parm: optional category filter
"""
if category is None:
return self._content
if category.lower() == 'archetypes':
return self._content.archetypes
if category.lower() == 'systems':
return self._content.systems
if category.lower() == 'generation_equipments':
return self._content.generation_equipments
raise ValueError(f'Unknown category [{category}]')
def get_entry(self, name):
"""
Get one catalog element by names
:parm: entry name
"""
for entry in self._content.archetypes:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.systems:
if entry.name.lower() == name.lower():
return entry
for entry in self._content.generation_equipments:
if entry.name.lower() == name.lower():
return entry
raise IndexError(f"{name} doesn't exists in the catalog")

View File

@ -9,6 +9,8 @@ from pathlib import Path
from typing import TypeVar
from hub.catalog_factories.energy_systems.montreal_custom_catalog import MontrealCustomCatalog
from hub.catalog_factories.energy_systems.montreal_future_system_catalogue import MontrealFutureSystemCatalogue
from hub.catalog_factories.energy_systems.palma_system_catalgue import PalmaSystemCatalogue
from hub.helpers.utils import validate_import_export_type
Catalog = TypeVar('Catalog')
@ -32,6 +34,20 @@ class EnergySystemsCatalogFactory:
"""
return MontrealCustomCatalog(self._path)
@property
def _montreal_future(self):
"""
Retrieve North American catalog
"""
return MontrealFutureSystemCatalogue(self._path)
@property
def _palma(self):
"""
Retrieve Palma catalog
"""
return PalmaSystemCatalogue(self._path)
@property
def catalog(self) -> Catalog:
"""

View File

@ -190,14 +190,14 @@ class ComnetCatalog(Catalog):
schedules_key = {}
for j in range(0, number_usage_types-1):
usage_parameters = _extracted_data.iloc[j]
usage_type = usage_parameters[0]
lighting_data[usage_type] = usage_parameters[1:6].values.tolist()
plug_loads_data[usage_type] = usage_parameters[8:13].values.tolist()
occupancy_data[usage_type] = usage_parameters[17:20].values.tolist()
ventilation_rate[usage_type] = usage_parameters[20:21].item()
water_heating[usage_type] = usage_parameters[23:24].item()
process_data[usage_type] = usage_parameters[24:26].values.tolist()
schedules_key[usage_type] = usage_parameters[27:28].item()
usage_type = usage_parameters.iloc[0]
lighting_data[usage_type] = usage_parameters.iloc[1:6].values.tolist()
plug_loads_data[usage_type] = usage_parameters.iloc[8:13].values.tolist()
occupancy_data[usage_type] = usage_parameters.iloc[17:20].values.tolist()
ventilation_rate[usage_type] = usage_parameters.iloc[20:21].item()
water_heating[usage_type] = usage_parameters.iloc[23:24].item()
process_data[usage_type] = usage_parameters.iloc[24:26].values.tolist()
schedules_key[usage_type] = usage_parameters.iloc[27:28].item()
return {'lighting': lighting_data,
'plug loads': plug_loads_data,

View File

@ -8,6 +8,8 @@ Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concord
import json
import urllib.request
from pathlib import Path
import xmltodict
import hub.helpers.constants as cte
@ -28,12 +30,11 @@ class NrcanCatalog(Catalog):
Nrcan catalog class
"""
def __init__(self, path):
path = str(path / 'nrcan.xml')
self._schedules_path = Path(path / 'nrcan_schedules.json').resolve()
self._space_types_path = Path(path / 'nrcan_space_types.json').resolve()
self._space_compliance_path = Path(path / 'nrcan_space_compliance_2015.json').resolve()
self._content = None
self._schedules = {}
with open(path, 'r', encoding='utf-8') as xml:
self._metadata = xmltodict.parse(xml.read())
self._base_url = self._metadata['nrcan']['@base_url']
self._load_schedules()
self._content = Content(self._load_archetypes())
@ -55,11 +56,9 @@ class NrcanCatalog(Catalog):
return Schedule(hub_type, raw['values'], data_type, time_step, time_range, day_types)
def _load_schedules(self):
usage = self._metadata['nrcan']
url = f'{self._base_url}{usage["schedules"]}'
_schedule_types = []
with urllib.request.urlopen(url) as json_file:
schedules_type = json.load(json_file)
with open(self._schedules_path, 'r') as f:
schedules_type = json.load(f)
for schedule_type in schedules_type['tables']['schedules']['table']:
schedule = NrcanCatalog._extract_schedule(schedule_type)
if schedule_type['name'] not in _schedule_types:
@ -80,14 +79,11 @@ class NrcanCatalog(Catalog):
def _load_archetypes(self):
usages = []
name = self._metadata['nrcan']
url_1 = f'{self._base_url}{name["space_types"]}'
url_2 = f'{self._base_url}{name["space_types_compliance"]}'
with urllib.request.urlopen(url_1) as json_file:
space_types = json.load(json_file)['tables']['space_types']['table']
with open(self._space_types_path, 'r') as f:
space_types = json.load(f)['tables']['space_types']['table']
space_types = [st for st in space_types if st['space_type'] == 'WholeBuilding']
with urllib.request.urlopen(url_2) as json_file:
space_types_compliance = json.load(json_file)['tables']['space_compliance']['table']
with open(self._space_compliance_path, 'r') as f:
space_types_compliance = json.load(f)['tables']['space_compliance']['table']
space_types_compliance = [st for st in space_types_compliance if st['space_type'] == 'WholeBuilding']
space_types_dictionary = {}
for space_type in space_types_compliance:

View File

@ -0,0 +1,227 @@
"""
Palma usage catalog
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Cecilia Pérez cperez@irec.cat
"""
import json
import urllib.request
from pathlib import Path
import xmltodict
import hub.helpers.constants as cte
from hub.catalog_factories.catalog import Catalog
from hub.catalog_factories.data_models.usages.appliances import Appliances
from hub.catalog_factories.data_models.usages.content import Content
from hub.catalog_factories.data_models.usages.lighting import Lighting
from hub.catalog_factories.data_models.usages.occupancy import Occupancy
from hub.catalog_factories.data_models.usages.domestic_hot_water import DomesticHotWater
from hub.catalog_factories.data_models.usages.schedule import Schedule
from hub.catalog_factories.data_models.usages.thermal_control import ThermalControl
from hub.catalog_factories.data_models.usages.usage import Usage
from hub.catalog_factories.usage.usage_helper import UsageHelper
class PalmaCatalog(Catalog):
"""
Palma catalog class
"""
def __init__(self, path):
self._schedules_path = Path(path / 'palma_schedules.json').resolve()
self._space_types_path = Path(path / 'palma_space_types.json').resolve()
self._space_compliance_path = Path(path / 'palma_space_compliance.json').resolve()
self._content = None
self._schedules = {}
self._load_schedules()
self._content = Content(self._load_archetypes())
@staticmethod
def _extract_schedule(raw):
nrcan_schedule_type = raw['category']
if 'Heating' in raw['name'] and 'Water' not in raw['name']:
nrcan_schedule_type = f'{nrcan_schedule_type} Heating'
elif 'Cooling' in raw['name']:
nrcan_schedule_type = f'{nrcan_schedule_type} Cooling'
if nrcan_schedule_type not in UsageHelper().nrcan_schedule_type_to_hub_schedule_type:
return None
hub_type = UsageHelper().nrcan_schedule_type_to_hub_schedule_type[nrcan_schedule_type]
data_type = UsageHelper().nrcan_data_type_to_hub_data_type[raw['units']]
time_step = UsageHelper().nrcan_time_to_hub_time[raw['type']]
# nrcan only uses daily range for the schedules
time_range = cte.DAY
day_types = UsageHelper().nrcan_day_type_to_hub_days[raw['day_types']]
return Schedule(hub_type, raw['values'], data_type, time_step, time_range, day_types)
def _load_schedules(self):
_schedule_types = []
with open(self._schedules_path, 'r') as f:
schedules_type = json.load(f)
for schedule_type in schedules_type['tables']['schedules']['table']:
schedule = PalmaCatalog._extract_schedule(schedule_type)
if schedule_type['name'] not in _schedule_types:
_schedule_types.append(schedule_type['name'])
if schedule is not None:
self._schedules[schedule_type['name']] = [schedule]
else:
if schedule is not None:
_schedules = self._schedules[schedule_type['name']]
_schedules.append(schedule)
self._schedules[schedule_type['name']] = _schedules
def _get_schedules(self, name):
schedule = None
if name in self._schedules:
schedule = self._schedules[name]
return schedule
def _load_archetypes(self):
usages = []
with open(self._space_types_path, 'r') as f:
space_types = json.load(f)['tables']['space_types']['table']
space_types = [st for st in space_types if st['space_type'] == 'WholeBuilding']
with open(self._space_compliance_path, 'r') as f:
space_types_compliance = json.load(f)['tables']['space_compliance']['table']
space_types_compliance = [st for st in space_types_compliance if st['space_type'] == 'WholeBuilding']
space_types_dictionary = {}
for space_type in space_types_compliance:
usage_type = space_type['building_type']
# people/m2
occupancy_density = space_type['occupancy_per_area_people_per_m2']
# W/m2
lighting_density = space_type['lighting_per_area_w_per_m2']
# W/m2
appliances_density = space_type['electric_equipment_per_area_w_per_m2']
# peak flow in gallons/h/m2
domestic_hot_water_peak_flow = (
space_type['service_water_heating_peak_flow_per_area'] *
cte.GALLONS_TO_QUBIC_METERS / cte.HOUR_TO_SECONDS
)
space_types_dictionary[usage_type] = {'occupancy_per_area': occupancy_density,
'lighting_per_area': lighting_density,
'electric_equipment_per_area': appliances_density,
'service_water_heating_peak_flow_per_area': domestic_hot_water_peak_flow
}
for space_type in space_types:
usage_type = space_type['building_type']
space_type_compliance = space_types_dictionary[usage_type]
occupancy_density = space_type_compliance['occupancy_per_area']
sensible_convective_internal_gain = space_type['sensible_convective_internal_gain']
sensible_radiative_internal_gain = space_type['sensible_radiative_internal_gain']
latent_internal_gain = space_type['latent_internal_gain']
lighting_density = space_type_compliance['lighting_per_area']
appliances_density = space_type_compliance['electric_equipment_per_area']
domestic_hot_water_peak_flow = space_type_compliance['service_water_heating_peak_flow_per_area']
occupancy_schedule_name = space_type['occupancy_schedule']
lighting_schedule_name = space_type['lighting_schedule']
appliance_schedule_name = space_type['electric_equipment_schedule']
hvac_schedule_name = space_type['exhaust_schedule']
if hvac_schedule_name and 'FAN' in hvac_schedule_name:
hvac_schedule_name = hvac_schedule_name.replace('FAN', 'Fan')
if not hvac_schedule_name:
hvac_schedule_name = 'default_HVAC_schedule'
heating_setpoint_schedule_name = space_type['heating_setpoint_schedule']
cooling_setpoint_schedule_name = space_type['cooling_setpoint_schedule']
domestic_hot_water_schedule_name = space_type['service_water_heating_schedule']
occupancy_schedule = self._get_schedules(occupancy_schedule_name)
lighting_schedule = self._get_schedules(lighting_schedule_name)
appliance_schedule = self._get_schedules(appliance_schedule_name)
heating_schedule = self._get_schedules(heating_setpoint_schedule_name)
cooling_schedule = self._get_schedules(cooling_setpoint_schedule_name)
hvac_availability = self._get_schedules(hvac_schedule_name)
domestic_hot_water_load_schedule = self._get_schedules(domestic_hot_water_schedule_name)
# ACH -> 1/s
mechanical_air_change = space_type['ventilation_air_changes'] / cte.HOUR_TO_SECONDS
# cfm/ft2 to m3/m2.s
ventilation_rate = space_type['ventilation_per_area'] / (cte.METERS_TO_FEET * cte.MINUTES_TO_SECONDS)
# cfm/person to m3/m2.s
ventilation_rate += space_type['ventilation_per_person'] / (
pow(cte.METERS_TO_FEET, 3) * cte.MINUTES_TO_SECONDS
) * occupancy_density
lighting_radiative_fraction = space_type['lighting_fraction_radiant']
lighting_convective_fraction = 0
if lighting_radiative_fraction is not None:
lighting_convective_fraction = 1 - lighting_radiative_fraction
lighting_latent_fraction = 0
appliances_radiative_fraction = space_type['electric_equipment_fraction_radiant']
appliances_latent_fraction = space_type['electric_equipment_fraction_latent']
appliances_convective_fraction = 0
if appliances_radiative_fraction is not None and appliances_latent_fraction is not None:
appliances_convective_fraction = 1 - appliances_radiative_fraction - appliances_latent_fraction
domestic_hot_water_service_temperature = space_type['service_water_heating_target_temperature']
occupancy = Occupancy(occupancy_density,
sensible_convective_internal_gain,
sensible_radiative_internal_gain,
latent_internal_gain,
occupancy_schedule)
lighting = Lighting(lighting_density,
lighting_convective_fraction,
lighting_radiative_fraction,
lighting_latent_fraction,
lighting_schedule)
appliances = Appliances(appliances_density,
appliances_convective_fraction,
appliances_radiative_fraction,
appliances_latent_fraction,
appliance_schedule)
thermal_control = ThermalControl(None,
None,
None,
hvac_availability,
heating_schedule,
cooling_schedule)
domestic_hot_water = DomesticHotWater(None,
domestic_hot_water_peak_flow,
domestic_hot_water_service_temperature,
domestic_hot_water_load_schedule)
hours_day = None
days_year = None
usages.append(Usage(usage_type,
hours_day,
days_year,
mechanical_air_change,
ventilation_rate,
occupancy,
lighting,
appliances,
thermal_control,
domestic_hot_water))
return usages
def names(self, category=None):
"""
Get the catalog elements names
:parm: for usage catalog category filter does nothing as there is only one category (usages)
"""
_names = {'usages': []}
for usage in self._content.usages:
_names['usages'].append(usage.name)
return _names
def entries(self, category=None):
"""
Get the catalog elements
:parm: for usage catalog category filter does nothing as there is only one category (usages)
"""
return self._content
def get_entry(self, name):
"""
Get one catalog element by names
:parm: entry name
"""
for usage in self._content.usages:
if usage.name.lower() == name.lower():
return usage
raise IndexError(f"{name} doesn't exists in the catalog")

View File

@ -11,6 +11,7 @@ from typing import TypeVar
from hub.catalog_factories.usage.comnet_catalog import ComnetCatalog
from hub.catalog_factories.usage.nrcan_catalog import NrcanCatalog
from hub.catalog_factories.usage.eilat_catalog import EilatCatalog
from hub.catalog_factories.usage.palma_catalog import PalmaCatalog
from hub.helpers.utils import validate_import_export_type
Catalog = TypeVar('Catalog')
@ -42,6 +43,13 @@ class UsageCatalogFactory:
# nrcan retrieves the data directly from github
return NrcanCatalog(self._path)
@property
def _palma(self):
"""
Retrieve Palma catalog
"""
return PalmaCatalog(self._path)
@property
def _eilat(self):
"""

View File

@ -27,7 +27,7 @@ class Building(CityObject):
"""
Building(CityObject) class
"""
def __init__(self, name, surfaces, year_of_construction, function, terrains=None, city=None):
def __init__(self, name, surfaces, year_of_construction, function, usages=None, terrains=None, city=None):
super().__init__(name, surfaces)
self._city = city
self._households = None
@ -36,6 +36,7 @@ class Building(CityObject):
self._terrains = terrains
self._year_of_construction = year_of_construction
self._function = function
self._usages = usages
self._average_storey_height = None
self._storeys_above_ground = None
self._floor_area = None
@ -89,7 +90,11 @@ class Building(CityObject):
elif surface.type == cte.INTERIOR_SLAB:
self._interior_slabs.append(surface)
else:
logging.error(f'Building %s [%s] has an unexpected surface type %s.', self.name, self.aliases, surface.type)
logging.error('Building %s [%s] has an unexpected surface type %s.', self.name, self.aliases, surface.type)
self._domestic_hot_water_peak_load = None
self._fuel_consumption_breakdown = {}
self._systems_archetype_cluster_id = None
self._pv_generation = {}
@property
def shell(self) -> Polyhedron:
@ -253,7 +258,17 @@ class Building(CityObject):
:param value: str
"""
if value is not None:
self._function = str(value)
self._function = value
@property
def usages(self) -> Union[None, list]:
"""
Get building usages, if none, assume usage is function
:return: None or list of functions
"""
if self._usages is None and self._function is not None:
self._usages = [{'usage': self._function, 'ratio': 1 }]
return self._usages
@property
def average_storey_height(self) -> Union[None, float]:
@ -289,7 +304,10 @@ class Building(CityObject):
"""
if self._storeys_above_ground is None:
if self.eave_height is not None and self.average_storey_height is not None:
self._storeys_above_ground = int(self.eave_height / self.average_storey_height)
storeys_above_ground = int(self.eave_height / self.average_storey_height)
if storeys_above_ground == 0:
storeys_above_ground += 1
self._storeys_above_ground = storeys_above_ground
return self._storeys_above_ground
@storeys_above_ground.setter
@ -448,8 +466,8 @@ class Building(CityObject):
monthly_values = PeakLoads(self).heating_peak_loads_from_methodology
if monthly_values is None:
return None
results[cte.MONTH] = [x * cte.WATTS_HOUR_TO_JULES for x in monthly_values]
results[cte.YEAR] = [max(monthly_values)]
results[cte.MONTH] = [x / cte.WATTS_HOUR_TO_JULES for x in monthly_values]
results[cte.YEAR] = [max(monthly_values) / cte.WATTS_HOUR_TO_JULES]
return results
@property
@ -465,8 +483,24 @@ class Building(CityObject):
monthly_values = PeakLoads(self).cooling_peak_loads_from_methodology
if monthly_values is None:
return None
results[cte.MONTH] = [x * cte.WATTS_HOUR_TO_JULES for x in monthly_values]
results[cte.YEAR] = [max(monthly_values)]
results[cte.MONTH] = [x / cte.WATTS_HOUR_TO_JULES for x in monthly_values]
results[cte.YEAR] = [max(monthly_values) / cte.WATTS_HOUR_TO_JULES]
return results
@property
def domestic_hot_water_peak_load(self) -> Union[None, dict]:
"""
Get cooling peak load in W
:return: dict{[float]}
"""
results = {}
monthly_values = None
if cte.HOUR in self.domestic_hot_water_heat_demand:
monthly_values = PeakLoads().peak_loads_from_hourly(self.domestic_hot_water_heat_demand[cte.HOUR])
if monthly_values is None:
return None
results[cte.MONTH] = [x / cte.WATTS_HOUR_TO_JULES for x in monthly_values]
results[cte.YEAR] = [max(monthly_values) / cte.WATTS_HOUR_TO_JULES]
return results
@property
@ -571,19 +605,6 @@ class Building(CityObject):
"""
self._city = value
@property
def usages_percentage(self):
"""
Get the usages and percentages for the building
"""
_usage = ''
for internal_zone in self.internal_zones:
if internal_zone.usages is None:
continue
for usage in internal_zone.usages:
_usage = f'{_usage}{usage.name}_{usage.percentage} '
return _usage.rstrip()
@property
def energy_systems(self) -> Union[None, List[EnergySystem]]:
"""
@ -702,6 +723,7 @@ class Building(CityObject):
Get total electricity consumption for distribution and emission systems in J
return: dict
"""
_distribution_systems_electrical_consumption = {}
if len(self._distribution_systems_electrical_consumption) != 0:
return self._distribution_systems_electrical_consumption
_peak_load = self.heating_peak_load[cte.YEAR][0]
@ -715,40 +737,43 @@ class Building(CityObject):
if self.energy_systems is None:
return self._distribution_systems_electrical_consumption
for energy_system in self.energy_systems:
emission_system = energy_system.emission_system.generic_emission_system
parasitic_energy_consumption = 0
if emission_system is not None:
parasitic_energy_consumption = emission_system.parasitic_energy_consumption
distribution_system = energy_system.distribution_system.generic_distribution_system
consumption_variable_flow = distribution_system.distribution_consumption_variable_flow
for demand_type in energy_system.demand_types:
if demand_type.lower() == cte.HEATING.lower():
if _peak_load_type == cte.HEATING.lower():
_consumption_fix_flow = distribution_system.distribution_consumption_fix_flow
for heating_demand_key in self.heating_demand:
_consumption = [0]*len(self.heating_demand[heating_demand_key])
_demand = self.heating_demand[heating_demand_key]
for i, _ in enumerate(_consumption):
_consumption[i] += (parasitic_energy_consumption + consumption_variable_flow) * _demand[i]
self._distribution_systems_electrical_consumption[heating_demand_key] = _consumption
if demand_type.lower() == cte.COOLING.lower():
if _peak_load_type == cte.COOLING.lower():
_consumption_fix_flow = distribution_system.distribution_consumption_fix_flow
for demand_key in self.cooling_demand:
_consumption = self._distribution_systems_electrical_consumption[demand_key]
_demand = self.cooling_demand[demand_key]
for i, _ in enumerate(_consumption):
_consumption[i] += (parasitic_energy_consumption + consumption_variable_flow) * _demand[i]
self._distribution_systems_electrical_consumption[demand_key] = _consumption
distribution_systems = energy_system.distribution_systems
if distribution_systems is not None:
for distribution_system in distribution_systems:
emission_systems = distribution_system.emission_systems
parasitic_energy_consumption = 0
if emission_systems is not None:
for emission_system in emission_systems:
parasitic_energy_consumption += emission_system.parasitic_energy_consumption
consumption_variable_flow = distribution_system.distribution_consumption_variable_flow
for demand_type in energy_system.demand_types:
if demand_type.lower() == cte.HEATING.lower():
if _peak_load_type == cte.HEATING.lower():
_consumption_fix_flow = distribution_system.distribution_consumption_fix_flow
for heating_demand_key in self.heating_demand:
_consumption = [0]*len(self.heating_demand[heating_demand_key])
_demand = self.heating_demand[heating_demand_key]
for i, _ in enumerate(_consumption):
_consumption[i] += (parasitic_energy_consumption + consumption_variable_flow) * _demand[i]
self._distribution_systems_electrical_consumption[heating_demand_key] = _consumption
if demand_type.lower() == cte.COOLING.lower():
if _peak_load_type == cte.COOLING.lower():
_consumption_fix_flow = distribution_system.distribution_consumption_fix_flow
for demand_key in self.cooling_demand:
_consumption = self._distribution_systems_electrical_consumption[demand_key]
_demand = self.cooling_demand[demand_key]
for i, _ in enumerate(_consumption):
_consumption[i] += (parasitic_energy_consumption + consumption_variable_flow) * _demand[i]
self._distribution_systems_electrical_consumption[demand_key] = _consumption
for key, item in self._distribution_systems_electrical_consumption.items():
for i in range(0, len(item)):
_working_hours_value = _working_hours[key]
if len(item) == 12:
_working_hours_value = _working_hours[key][i]
self._distribution_systems_electrical_consumption[key][i] += (
_peak_load * _consumption_fix_flow * _working_hours_value * cte.WATTS_HOUR_TO_JULES
)
for key, item in self._distribution_systems_electrical_consumption.items():
for i in range(0, len(item)):
_working_hours_value = _working_hours[key]
if len(item) == 12:
_working_hours_value = _working_hours[key][i]
self._distribution_systems_electrical_consumption[key][i] += (
_peak_load * _consumption_fix_flow * _working_hours_value * cte.WATTS_HOUR_TO_JULES
)
return self._distribution_systems_electrical_consumption
@ -758,15 +783,21 @@ class Building(CityObject):
if self.energy_systems is None:
return None
for energy_system in self.energy_systems:
generation_systems = energy_system.generation_systems
for demand_type in energy_system.demand_types:
if demand_type.lower() == consumption_type.lower():
if consumption_type in (cte.HEATING, cte.DOMESTIC_HOT_WATER):
coefficient_of_performance = energy_system.generation_system.generic_generation_system.heat_efficiency
for generation_system in generation_systems:
if generation_system.heat_efficiency is not None:
coefficient_of_performance = float(generation_system.heat_efficiency)
elif consumption_type == cte.COOLING:
coefficient_of_performance = energy_system.generation_system.generic_generation_system.cooling_efficiency
for generation_system in generation_systems:
if generation_system.cooling_efficiency is not None:
coefficient_of_performance = float(generation_system.cooling_efficiency)
elif consumption_type == cte.ELECTRICITY:
coefficient_of_performance = \
energy_system.generation_system.generic_generation_system.electricity_efficiency
for generation_system in generation_systems:
if generation_system.electricity_efficiency is not None:
coefficient_of_performance = float(generation_system.electricity_efficiency)
if coefficient_of_performance == 0:
values = [0]*len(demand)
final_energy_consumed = values
@ -797,18 +828,22 @@ class Building(CityObject):
if self.energy_systems is None:
return self._onsite_electrical_production
for energy_system in self.energy_systems:
if energy_system.generation_system.generic_generation_system.type == cte.PHOTOVOLTAIC:
_efficiency = energy_system.generation_system.generic_generation_system.electricity_efficiency
self._onsite_electrical_production = {}
for _key in self.roofs[0].global_irradiance.keys():
_results = [0 for _ in range(0, len(self.roofs[0].global_irradiance[_key]))]
for surface in self.roofs:
if _key in orientation_losses_factor:
_results = [x + y * _efficiency * surface.perimeter_area
* surface.solar_collectors_area_reduction_factor * z
for x, y, z in zip(_results, surface.global_irradiance[_key],
orientation_losses_factor[_key]['south'])]
self._onsite_electrical_production[_key] = _results
for generation_system in energy_system.generation_systems:
if generation_system.system_type == cte.PHOTOVOLTAIC:
if generation_system.electricity_efficiency is not None:
_efficiency = float(generation_system.electricity_efficiency)
else:
_efficiency = 0
self._onsite_electrical_production = {}
for _key in self.roofs[0].global_irradiance.keys():
_results = [0 for _ in range(0, len(self.roofs[0].global_irradiance[_key]))]
for surface in self.roofs:
if _key in orientation_losses_factor:
_results = [x + y * _efficiency * surface.perimeter_area
* surface.solar_collectors_area_reduction_factor * z
for x, y, z in zip(_results, surface.global_irradiance[_key],
orientation_losses_factor[_key]['south'])]
self._onsite_electrical_production[_key] = _results
return self._onsite_electrical_production
@property
@ -824,3 +859,94 @@ class Building(CityObject):
Get building upper corner.
"""
return [self._max_x, self._max_y, self._max_z]
@property
def energy_consumption_breakdown(self) -> dict:
"""
Get energy consumption of different sectors
return: dict
"""
fuel_breakdown = {cte.ELECTRICITY: {cte.LIGHTING: self.lighting_electrical_demand[cte.YEAR][0] if self.lighting_electrical_demand else 0,
cte.APPLIANCES: self.appliances_electrical_demand[cte.YEAR][0] if self.appliances_electrical_demand else 0}}
energy_systems = self.energy_systems
if energy_systems is not None:
for energy_system in energy_systems:
demand_types = energy_system.demand_types
generation_systems = energy_system.generation_systems
for demand_type in demand_types:
for generation_system in generation_systems:
if generation_system.system_type != cte.PHOTOVOLTAIC:
if generation_system.fuel_type not in fuel_breakdown:
fuel_breakdown[generation_system.fuel_type] = {}
if demand_type in generation_system.energy_consumption:
fuel_breakdown[f'{generation_system.fuel_type}'][f'{demand_type}'] = (
generation_system.energy_consumption)[f'{demand_type}'][cte.YEAR][0]
storage_systems = generation_system.energy_storage_systems
if storage_systems:
for storage_system in storage_systems:
if storage_system.type_energy_stored == 'thermal' and storage_system.heating_coil_energy_consumption:
fuel_breakdown[cte.ELECTRICITY][f'{demand_type}'] += (
storage_system.heating_coil_energy_consumption)[f'{demand_type}'][cte.YEAR][0]
#TODO: When simulation models of all energy system archetypes are created, this part can be removed
heating_fuels = []
dhw_fuels = []
for energy_system in self.energy_systems:
if cte.HEATING in energy_system.demand_types:
for generation_system in energy_system.generation_systems:
heating_fuels.append(generation_system.fuel_type)
if cte.DOMESTIC_HOT_WATER in energy_system.demand_types:
for generation_system in energy_system.generation_systems:
dhw_fuels.append(generation_system.fuel_type)
for key in fuel_breakdown:
if key == cte.ELECTRICITY and cte.COOLING not in fuel_breakdown[key]:
for energy_system in energy_systems:
if cte.COOLING in energy_system.demand_types and cte.COOLING not in fuel_breakdown[key]:
if self.cooling_consumption:
fuel_breakdown[energy_system.generation_systems[0].fuel_type][cte.COOLING] = self.cooling_consumption[cte.YEAR][0]
for fuel in heating_fuels:
if cte.HEATING not in fuel_breakdown[fuel]:
for energy_system in energy_systems:
if cte.HEATING in energy_system.demand_types:
if self.heating_consumption:
fuel_breakdown[energy_system.generation_systems[0].fuel_type][cte.HEATING] = self.heating_consumption[cte.YEAR][0]
for fuel in dhw_fuels:
if cte.DOMESTIC_HOT_WATER not in fuel_breakdown[fuel]:
for energy_system in energy_systems:
if cte.DOMESTIC_HOT_WATER in energy_system.demand_types:
if self.domestic_hot_water_consumption:
fuel_breakdown[energy_system.generation_systems[0].fuel_type][cte.DOMESTIC_HOT_WATER] = self.domestic_hot_water_consumption[cte.YEAR][0]
self._fuel_consumption_breakdown = fuel_breakdown
return self._fuel_consumption_breakdown
@property
def energy_systems_archetype_cluster_id(self):
"""
Get energy systems archetype id
:return: str
"""
return self._systems_archetype_cluster_id
@energy_systems_archetype_cluster_id.setter
def energy_systems_archetype_cluster_id(self, value):
"""
Set energy systems archetype id
:param value: str
"""
self._systems_archetype_cluster_id = value
@property
def pv_generation(self):
"""
temporary attribute to get the onsite pv generation in W
:return: dict
"""
return self._pv_generation
@pv_generation.setter
def pv_generation(self, value):
"""
temporary attribute to set the onsite pv generation in W
:param value: float
"""
self._pv_generation = value

View File

@ -132,7 +132,11 @@ class InternalZone:
_thermal_boundary = ThermalBoundary(surface, surface.solid_polygon.area, windows_areas)
surface.associated_thermal_boundaries = [_thermal_boundary]
_thermal_boundaries.append(_thermal_boundary)
if self.thermal_archetype is None:
return None # there are no archetype
_number_of_storeys = int(self.volume / self.area / self.thermal_archetype.average_storey_height)
if _number_of_storeys == 0:
_number_of_storeys = 1
_thermal_zone = ThermalZone(_thermal_boundaries, self, self.volume, self.area, _number_of_storeys)
for thermal_boundary in _thermal_zone.thermal_boundaries:
thermal_boundary.thermal_zones = [_thermal_zone]

View File

@ -42,10 +42,12 @@ class Surface:
self._short_wave_reflectance = None
self._long_wave_emittance = None
self._inverse = None
self._associated_thermal_boundaries = []
self._associated_thermal_boundaries = None
self._vegetation = None
self._percentage_shared = None
self._solar_collectors_area_reduction_factor = None
self._global_irradiance_tilted = {}
self._installed_solar_collector_area = None
@property
def name(self):
@ -155,6 +157,7 @@ class Surface:
if self._inclination is None:
self._inclination = np.arccos(self.perimeter_polygon.normal[2])
return self._inclination
@property
def type(self):
"""
@ -178,7 +181,7 @@ class Surface:
@property
def global_irradiance(self) -> dict:
"""
Get global irradiance on surface in J/m2
Get global irradiance on surface in W/m2
:return: dict
"""
return self._global_irradiance
@ -186,7 +189,7 @@ class Surface:
@global_irradiance.setter
def global_irradiance(self, value):
"""
Set global irradiance on surface in J/m2
Set global irradiance on surface in W/m2
:param value: dict
"""
self._global_irradiance = value
@ -384,3 +387,35 @@ class Surface:
:param value: float
"""
self._solar_collectors_area_reduction_factor = value
@property
def global_irradiance_tilted(self) -> dict:
"""
Get global irradiance on a tilted surface in W/m2
:return: dict
"""
return self._global_irradiance_tilted
@global_irradiance_tilted.setter
def global_irradiance_tilted(self, value):
"""
Set global irradiance on a tilted surface in W/m2
:param value: dict
"""
self._global_irradiance_tilted = value
@property
def installed_solar_collector_area(self):
"""
Get installed solar collector area in m2
:return: dict
"""
return self._installed_solar_collector_area
@installed_solar_collector_area.setter
def installed_solar_collector_area(self, value):
"""
Set installed solar collector area in m2
:return: dict
"""
self._installed_solar_collector_area = value

View File

@ -20,6 +20,8 @@ class ThermalArchetype:
self._indirect_heated_ratio = None
self._infiltration_rate_for_ventilation_system_off = None
self._infiltration_rate_for_ventilation_system_on = None
self._infiltration_rate_area_for_ventilation_system_off=None
self._infiltration_rate_area_for_ventilation_system_on=None
@property
def constructions(self) -> [Construction]:
@ -132,3 +134,35 @@ class ThermalArchetype:
:param value: float
"""
self._infiltration_rate_for_ventilation_system_on = value
@property
def infiltration_rate_area_for_ventilation_system_off(self):
"""
Get infiltration rate for ventilation system off in l/s/m2
:return: float
"""
return self._infiltration_rate_for_ventilation_system_off
@infiltration_rate_area_for_ventilation_system_off.setter
def infiltration_rate_area_for_ventilation_system_off(self, value):
"""
Set infiltration rate for ventilation system off in l/s/m2
:param value: float
"""
self._infiltration_rate_for_ventilation_system_off = value
@property
def infiltration_rate_area_for_ventilation_system_on(self):
"""
Get infiltration rate for ventilation system on in l/s/m2
:return: float
"""
return self._infiltration_rate_for_ventilation_system_on
@infiltration_rate_area_for_ventilation_system_on.setter
def infiltration_rate_area_for_ventilation_system_on(self, value):
"""
Set infiltration rate for ventilation system on in l/s/m2
:param value: float
"""
self._infiltration_rate_for_ventilation_system_on = value

View File

@ -34,7 +34,7 @@ class ThermalZone:
volume,
footprint_area,
number_of_storeys,
usage_name=None):
usages=None):
self._id = None
self._parent_internal_zone = parent_internal_zone
self._footprint_area = footprint_area
@ -44,15 +44,13 @@ class ThermalZone:
self._indirectly_heated_area_ratio = None
self._infiltration_rate_system_on = None
self._infiltration_rate_system_off = None
self._infiltration_rate_area_system_on = None
self._infiltration_rate_area_system_off = None
self._volume = volume
self._ordinate_number = None
self._view_factors_matrix = None
self._total_floor_area = None
self._number_of_storeys = number_of_storeys
self._usage_name = usage_name
self._usage_from_parent = False
if usage_name is None:
self._usage_from_parent = True
self._hours_day = None
self._days_year = None
self._mechanical_air_change = None
@ -62,7 +60,12 @@ class ThermalZone:
self._internal_gains = None
self._thermal_control = None
self._domestic_hot_water = None
self._usages = None
self._usage_name = None
self._usages = usages
self._usage_from_parent = False
if usages is None:
self._usage_from_parent = True
@property
def parent_internal_zone(self) -> InternalZone:
@ -75,24 +78,11 @@ class ThermalZone:
@property
def usages(self):
"""
Get the thermal zone usages including percentage with the format [percentage]-usage_[percentage]-usage...
Eg: 70-office_30-residential
Get the thermal zone usages
:return: str
"""
if self._usage_from_parent:
self._usages = copy.deepcopy(self._parent_internal_zone.usages)
else:
values = self._usage_name.split('_')
usages = []
for value in values:
usages.append(value.split('-'))
self._usages = []
for parent_usage in self._parent_internal_zone.usages:
for value in usages:
if parent_usage.name == value[1]:
new_usage = copy.deepcopy(parent_usage)
new_usage.percentage = float(value[0]) / 100
self._usages.append(new_usage)
return self._usages
@property
@ -166,6 +156,24 @@ class ThermalZone:
self._infiltration_rate_system_off = self._parent_internal_zone.thermal_archetype.infiltration_rate_for_ventilation_system_off
return self._infiltration_rate_system_off
@property
def infiltration_rate_area_system_on(self):
"""
Get thermal zone infiltration rate system on in air changes per second (1/s)
:return: None or float
"""
self._infiltration_rate_area_system_on = self._parent_internal_zone.thermal_archetype.infiltration_rate_area_for_ventilation_system_on
return self._infiltration_rate_area_system_on
@property
def infiltration_rate_area_system_off(self):
"""
Get thermal zone infiltration rate system off in air changes per second (1/s)
:return: None or float
"""
self._infiltration_rate_area_system_off = self._parent_internal_zone.thermal_archetype.infiltration_rate_area_for_ventilation_system_off
return self._infiltration_rate_area_system_off
@property
def volume(self):
"""

View File

@ -62,7 +62,6 @@ class City:
self._level_of_detail = LevelOfDetail()
self._city_objects_dictionary = {}
self._city_objects_alias_dictionary = {}
self._energy_systems_connection_table = None
self._generic_energy_systems = None
def _get_location(self) -> Location:
@ -505,24 +504,6 @@ class City:
"""
return self._level_of_detail
@property
def energy_systems_connection_table(self) -> Union[None, DataFrame]:
"""
Get energy systems connection table which includes at least two columns: energy_system_type and associated_building
and may also include dimensioned_energy_system and connection_building_to_dimensioned_energy_system
:return: DataFrame
"""
return self._energy_systems_connection_table
@energy_systems_connection_table.setter
def energy_systems_connection_table(self, value):
"""
Set energy systems connection table which includes at least two columns: energy_system_type and associated_building
and may also include dimensioned_energy_system and connection_building_to_dimensioned_energy_system
:param value: DataFrame
"""
self._energy_systems_connection_table = value
@property
def generic_energy_systems(self) -> dict:
"""

View File

@ -41,9 +41,10 @@ class CityObject:
self._ground_temperature = {}
self._global_horizontal = {}
self._diffuse = {}
self._beam = {}
self._direct_normal = {}
self._sensors = []
self._neighbours = None
self._beam = {}
@property
def level_of_detail(self) -> LevelOfDetail:
@ -238,20 +239,20 @@ class CityObject:
self._diffuse = value
@property
def beam(self) -> dict:
def direct_normal(self) -> dict:
"""
Get beam radiation surrounding the city object in J/m2
:return: dict{dict{[float]}}
"""
return self._beam
return self._direct_normal
@beam.setter
def beam(self, value):
@direct_normal.setter
def direct_normal(self, value):
"""
Set beam radiation surrounding the city object in J/m2
:param value: dict{dict{[float]}}
"""
self._beam = value
self._direct_normal = value
@property
def lower_corner(self):
@ -302,3 +303,19 @@ class CityObject:
Set the list of neighbour_objects and their properties associated to the current city_object
"""
self._neighbours = value
@property
def beam(self) -> dict:
"""
Get beam radiation surrounding the city object in J/m2
:return: dict{dict{[float]}}
"""
return self._beam
@beam.setter
def beam(self, value):
"""
Set beam radiation surrounding the city object in J/m2
:param value: dict{dict{[float]}}
"""
self._beam = value

View File

@ -5,7 +5,12 @@ Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from hub.city_model_structure.energy_systems.generic_distribution_system import GenericDistributionSystem
from typing import Union, List, TypeVar
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
GenerationSystem = TypeVar('GenerationSystem')
class DistributionSystem:
@ -13,20 +18,158 @@ class DistributionSystem:
DistributionSystem class
"""
def __init__(self):
self._generic_distribution_system = None
self._model_name = None
self._type = None
self._supply_temperature = None
self._distribution_consumption_fix_flow = None
self._distribution_consumption_variable_flow = None
self._heat_losses = None
self._generation_systems = None
self._energy_storage_systems = None
self._emission_systems = None
@property
def generic_distribution_system(self) -> GenericDistributionSystem:
def model_name(self):
"""
Get generic_distribution_system
:return: GenericDistributionSystem
Get model name
:return: string
"""
return self._generic_distribution_system
return self._model_name
@generic_distribution_system.setter
def generic_distribution_system(self, value):
@model_name.setter
def model_name(self, value):
"""
Set associated generic_distribution_system
:param value: GenericDistributionSystem
Set model name
:param value: string
"""
self._generic_distribution_system = value
self._model_name = value
@property
def type(self):
"""
Get type from [air, water, refrigerant]
:return: string
"""
return self._type
@type.setter
def type(self, value):
"""
Set type from [air, water, refrigerant]
:param value: string
"""
self._type = value
@property
def supply_temperature(self):
"""
Get supply_temperature in degree Celsius
:return: float
"""
return self._supply_temperature
@supply_temperature.setter
def supply_temperature(self, value):
"""
Set supply_temperature in degree Celsius
:param value: float
"""
self._supply_temperature = value
@property
def distribution_consumption_fix_flow(self):
"""
Get distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
:return: float
"""
return self._distribution_consumption_fix_flow
@distribution_consumption_fix_flow.setter
def distribution_consumption_fix_flow(self, value):
"""
Set distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
:return: float
"""
self._distribution_consumption_fix_flow = value
@property
def distribution_consumption_variable_flow(self):
"""
Get distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
over energy produced (J/J)
:return: float
"""
return self._distribution_consumption_variable_flow
@distribution_consumption_variable_flow.setter
def distribution_consumption_variable_flow(self, value):
"""
Set distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
over energy produced (J/J)
:return: float
"""
self._distribution_consumption_variable_flow = value
@property
def heat_losses(self):
"""
Get heat_losses in ratio over energy produced
:return: float
"""
return self._heat_losses
@heat_losses.setter
def heat_losses(self, value):
"""
Set heat_losses in ratio over energy produced
:param value: float
"""
self._heat_losses = value
@property
def generation_systems(self) -> Union[None, List[GenerationSystem]]:
"""
Get generation systems connected to the distribution system
:return: [GenerationSystem]
"""
return self._generation_systems
@generation_systems.setter
def generation_systems(self, value):
"""
Set generation systems connected to the distribution system
:param value: [GenerationSystem]
"""
self._generation_systems = value
@property
def energy_storage_systems(self) -> Union[None, List[EnergyStorageSystem]]:
"""
Get energy storage systems connected to this distribution system
:return: [EnergyStorageSystem]
"""
return self._energy_storage_systems
@energy_storage_systems.setter
def energy_storage_systems(self, value):
"""
Set energy storage systems connected to this distribution system
:param value: [EnergyStorageSystem]
"""
self._energy_storage_systems = value
@property
def emission_systems(self) -> Union[None, List[EmissionSystem]]:
"""
Get energy emission systems connected to this distribution system
:return: [EmissionSystem]
"""
return self._emission_systems
@emission_systems.setter
def emission_systems(self, value):
"""
Set energy emission systems connected to this distribution system
:param value: [EmissionSystem]
"""
self._emission_systems = value

View File

@ -0,0 +1,104 @@
"""
Electrical storage system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
class ElectricalStorageSystem(EnergyStorageSystem):
""""
Electrical Storage System Class
"""
def __init__(self):
super().__init__()
self._rated_output_power = None
self._nominal_efficiency = None
self._battery_voltage = None
self._depth_of_discharge = None
self._self_discharge_rate = None
@property
def rated_output_power(self):
"""
Get the rated output power of storage system in Watts
:return: float
"""
return self._rated_output_power
@rated_output_power.setter
def rated_output_power(self, value):
"""
Set the rated output power of storage system in Watts
:param value: float
"""
self._rated_output_power = value
@property
def nominal_efficiency(self):
"""
Get the nominal efficiency of the storage system
:return: float
"""
return self._nominal_efficiency
@nominal_efficiency.setter
def nominal_efficiency(self, value):
"""
Set the nominal efficiency of the storage system
:param value: float
"""
self._nominal_efficiency = value
@property
def battery_voltage(self):
"""
Get the battery voltage in Volts
:return: float
"""
return self._battery_voltage
@battery_voltage.setter
def battery_voltage(self, value):
"""
Set the battery voltage in Volts
:param value: float
"""
self._battery_voltage = value
@property
def depth_of_discharge(self):
"""
Get the depth of discharge as a percentage
:return: float
"""
return self._depth_of_discharge
@depth_of_discharge.setter
def depth_of_discharge(self, value):
"""
Set the depth of discharge as a percentage
:param value: float
"""
self._depth_of_discharge = value
@property
def self_discharge_rate(self):
"""
Get the self discharge rate of battery as a percentage
:return: float
"""
return self._self_discharge_rate
@self_discharge_rate.setter
def self_discharge_rate(self, value):
"""
Set the self discharge rate of battery as a percentage
:param value: float
"""
self._self_discharge_rate = value

View File

@ -1,32 +1,64 @@
"""
Energy emission system definition
Emission system module
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from hub.city_model_structure.energy_systems.generic_emission_system import GenericEmissionSystem
class EmissionSystem:
"""
EmissionSystem class
"""
def __init__(self):
self._generic_emission_system = None
self._model_name = None
self._type = None
self._parasitic_energy_consumption = 0
@property
def generic_emission_system(self) -> GenericEmissionSystem:
def model_name(self):
"""
Get associated generic_emission_system
:return: GenericEmissionSystem
Get model name
:return: string
"""
return self._generic_emission_system
return self._model_name
@generic_emission_system.setter
def generic_emission_system(self, value):
@model_name.setter
def model_name(self, value):
"""
Set associated
:param value: GenericEmissionSystem
Set model name
:param value: string
"""
self._generic_emission_system = value
self._model_name = value
@property
def type(self):
"""
Get type
:return: string
"""
return self._type
@type.setter
def type(self, value):
"""
Set type
:param value: string
"""
self._type = value
@property
def parasitic_energy_consumption(self):
"""
Get parasitic_energy_consumption in ratio (W/W)
:return: float
"""
return self._parasitic_energy_consumption
@parasitic_energy_consumption.setter
def parasitic_energy_consumption(self, value):
"""
Set parasitic_energy_consumption in ratio (W/W)
:param value: float
"""
self._parasitic_energy_consumption = value

View File

@ -0,0 +1,118 @@
"""
Energy storage system. Abstract class
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from abc import ABC
class EnergyStorageSystem(ABC):
"""
Energy storage System class
"""
def __init__(self):
self._type_energy_stored = None
self._storage_type = None
self._model_name = None
self._manufacturer = None
self._nominal_capacity = None
self._losses_ratio = None
@property
def type_energy_stored(self):
"""
Get type of energy stored from ['electrical', 'thermal']
:return: string
"""
return self._type_energy_stored
@type_energy_stored.setter
def type_energy_stored(self, value):
"""
Set type of energy stored from ['electrical', 'thermal']
:return: string
"""
self._type_energy_stored = value
@property
def storage_type(self):
"""
Get storage type
:return: string
"""
return self._storage_type
@storage_type.setter
def storage_type(self, value):
"""
Get storage type
:param value: string
"""
self._storage_type = value
@property
def model_name(self):
"""
Get system model
:return: string
"""
return self._model_name
@model_name.setter
def model_name(self, value):
"""
Set system model
:param value: string
"""
self._model_name = value
@property
def manufacturer(self):
"""
Get name of manufacturer
:return: string
"""
return self._manufacturer
@manufacturer.setter
def manufacturer(self, value):
"""
Set name of manufacturer
:param value: string
"""
self._manufacturer = value
@property
def nominal_capacity(self):
"""
Get the nominal capacity of storage systems in Jules
:return: float
"""
return self._nominal_capacity
@nominal_capacity.setter
def nominal_capacity(self, value):
"""
Set the nominal capacity of storage systems in Jules
:return: float
"""
self._nominal_capacity = value
@property
def losses_ratio(self):
"""
Get the losses-ratio of storage system in Jules lost / Jules stored
:return: float
"""
return self._losses_ratio
@losses_ratio.setter
def losses_ratio(self, value):
"""
Set the losses-ratio of storage system in Jules lost / Jules stored
:return: float
"""
self._losses_ratio = value

View File

@ -6,10 +6,11 @@ Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from typing import Union, List
from pathlib import Path
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
from hub.city_model_structure.energy_systems.emission_system import EmissionSystem
from hub.city_model_structure.energy_systems.non_pv_generation_system import NonPvGenerationSystem
from hub.city_model_structure.energy_systems.pv_generation_system import PvGenerationSystem
from hub.city_model_structure.energy_systems.control_system import ControlSystem
from hub.city_model_structure.city_object import CityObject
@ -19,30 +20,14 @@ class EnergySystem:
EnergySystem class
"""
def __init__(self):
self._name = None
self._demand_types = None
self._generation_system = None
self._distribution_system = None
self._emission_system = None
self._name = None
self._generation_systems = None
self._distribution_systems = None
self._configuration_schema = None
self._connected_city_objects = None
self._control_system = None
@property
def name(self):
"""
Get energy system name
:return: str
"""
return self._name
@name.setter
def name(self, value):
"""
Set energy system name
:param value:
"""
self._name = value
@property
def demand_types(self):
"""
@ -60,58 +45,74 @@ class EnergySystem:
self._demand_types = value
@property
def generation_system(self) -> GenerationSystem:
def name(self):
"""
Get generation system
:return: GenerationSystem
Get energy system name
:return: str
"""
return self._generation_system
return self._name
@generation_system.setter
def generation_system(self, value):
@name.setter
def name(self, value):
"""
Set generation system
:param value: GenerationSystem
Set energy system name
:param value:
"""
self._generation_system = value
self._name = value
@property
def distribution_system(self) -> Union[None, DistributionSystem]:
def generation_systems(self) -> Union[List[NonPvGenerationSystem], List[PvGenerationSystem]]:
"""
Get distribution system
:return: DistributionSystem
Get generation systems
:return: [GenerationSystem]
"""
return self._distribution_system
return self._generation_systems
@distribution_system.setter
def distribution_system(self, value):
@generation_systems.setter
def generation_systems(self, value):
"""
Set distribution system
:param value: DistributionSystem
Set generation systems
:return: [GenerationSystem]
"""
self._distribution_system = value
self._generation_systems = value
@property
def emission_system(self) -> Union[None, EmissionSystem]:
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
"""
Get emission system
:return: EmissionSystem
Get distribution systems
:return: [DistributionSystem]
"""
return self._emission_system
return self._distribution_systems
@emission_system.setter
def emission_system(self, value):
@distribution_systems.setter
def distribution_systems(self, value):
"""
Set emission system
:param value: EmissionSystem
Set distribution systems
:param value: [DistributionSystem]
"""
self._emission_system = value
self._distribution_systems = value
@property
def configuration_schema(self) -> Path:
"""
Get the schema of the system configuration
:return: Path
"""
return self._configuration_schema
@configuration_schema.setter
def configuration_schema(self, value):
"""
Set the schema of the system configuration
:param value: Path
"""
self._configuration_schema = value
@property
def connected_city_objects(self) -> Union[None, List[CityObject]]:
"""
Get list of city objects that are connected to this energy system
:return: List[CityObject]
:return: [CityObject]
"""
return self._connected_city_objects
@ -119,7 +120,7 @@ class EnergySystem:
def connected_city_objects(self, value):
"""
Set list of city objects that are connected to this energy system
:param value: List[CityObject]
:param value: [CityObject]
"""
self._connected_city_objects = value

View File

@ -1,120 +1,158 @@
"""
Energy generation system definition
Energy generation system (abstract class)
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from __future__ import annotations
from typing import Union
from abc import ABC
from typing import Union, List
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
from hub.city_model_structure.energy_systems.distribution_system import DistributionSystem
from hub.city_model_structure.energy_systems.thermal_storage_system import ThermalStorageSystem
from hub.city_model_structure.energy_systems.electrical_storage_system import ElectricalStorageSystem
class GenerationSystem:
class GenerationSystem(ABC):
"""
GenerationSystem class
"""
def __init__(self):
self._heat_power = None
self._cooling_power = None
self._electricity_power = None
self._storage_capacity = None
self._generic_generation_system = None
self._auxiliary_equipment = None
self._system_type = None
self._name = None
self._model_name = None
self._manufacturer = None
self._fuel_type = None
self._distribution_systems = None
self._energy_storage_systems = None
self._number_of_units = None
@property
def generic_generation_system(self) -> GenericGenerationSystem:
def system_type(self):
"""
Get associated generic_generation_system
:return: GenericGenerationSystem
Get type
:return: string
"""
return self._generic_generation_system
return self._system_type
@generic_generation_system.setter
def generic_generation_system(self, value):
@system_type.setter
def system_type(self, value):
"""
Set associated generic_generation_system
:param value: GenericGenerationSystem
Set type
:param value: string
"""
self._generic_generation_system = value
self._system_type = value
@property
def heat_power(self):
def name(self):
"""
Get heat_power in W
:return: float
Get name
:return: string
"""
return self._heat_power
return self._name
@heat_power.setter
def heat_power(self, value):
@name.setter
def name(self, value):
"""
Set heat_power in W
:param value: float
Set name
:param value: string
"""
self._heat_power = value
self._name = value
@property
def cooling_power(self):
def model_name(self):
"""
Get cooling_power in W
:return: float
Get model name
:return: string
"""
return self._cooling_power
return self._model_name
@cooling_power.setter
def cooling_power(self, value):
@model_name.setter
def model_name(self, value):
"""
Set cooling_power in W
:param value: float
Set model name
:param value: string
"""
self._cooling_power = value
self._model_name = value
@property
def electricity_power(self):
def manufacturer(self):
"""
Get electricity_power in W
:return: float
Get manufacturer's name
:return: string
"""
return self._electricity_power
return self._manufacturer
@electricity_power.setter
def electricity_power(self, value):
@manufacturer.setter
def manufacturer(self, value):
"""
Set electricity_power in W
:param value: float
Set manufacturer's name
:param value: string
"""
self._electricity_power = value
self._manufacturer = value
@property
def storage_capacity(self):
def fuel_type(self):
"""
Get storage_capacity in J
:return: float
Get fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
:return: string
"""
return self._storage_capacity
return self._fuel_type
@storage_capacity.setter
def storage_capacity(self, value):
@fuel_type.setter
def fuel_type(self, value):
"""
Set storage_capacity in J
:param value: float
Set fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
:param value: string
"""
self._storage_capacity = value
self._fuel_type = value
@property
def auxiliary_equipment(self) -> Union[None, GenerationSystem]:
def distribution_systems(self) -> Union[None, List[DistributionSystem]]:
"""
Get auxiliary_equipment
:return: GenerationSystem
Get distributions systems connected to this generation system
:return: [DistributionSystem]
"""
return self._auxiliary_equipment
return self._distribution_systems
@auxiliary_equipment.setter
def auxiliary_equipment(self, value):
@distribution_systems.setter
def distribution_systems(self, value):
"""
Set auxiliary_equipment
:param value: GenerationSystem
Set distributions systems connected to this generation system
:param value: [DistributionSystem]
"""
self._auxiliary_equipment = value
self._distribution_systems = value
@property
def energy_storage_systems(self) -> Union[None, List[ThermalStorageSystem], List[ElectricalStorageSystem]]:
"""
Get energy storage systems connected to this generation system
:return: [EnergyStorageSystem]
"""
return self._energy_storage_systems
@energy_storage_systems.setter
def energy_storage_systems(self, value):
"""
Set energy storage systems connected to this generation system
:param value: [EnergyStorageSystem]
"""
self._energy_storage_systems = value
@property
def number_of_units(self):
"""
Get number of a specific generation unit
:return: int
"""
return self._number_of_units
@number_of_units.setter
def number_of_units(self, value):
"""
Set number of a specific generation unit
:return: int
"""
self._number_of_units = value

View File

@ -1,100 +0,0 @@
"""
Generic energy distribution system definition
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
class GenericDistributionSystem:
"""
GenericDistributionSystem class
"""
def __init__(self):
self._type = None
self._supply_temperature = None
self._distribution_consumption_fix_flow = None
self._distribution_consumption_variable_flow = None
self._heat_losses = None
@property
def type(self):
"""
Get type from [air, water, refrigerant]
:return: string
"""
return self._type
@type.setter
def type(self, value):
"""
Set type from [air, water, refrigerant]
:param value: string
"""
self._type = value
@property
def supply_temperature(self):
"""
Get supply_temperature in degree Celsius
:return: float
"""
return self._supply_temperature
@supply_temperature.setter
def supply_temperature(self, value):
"""
Set supply_temperature in degree Celsius
:param value: float
"""
self._supply_temperature = value
@property
def distribution_consumption_fix_flow(self):
"""
Get distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
:return: float
"""
return self._distribution_consumption_fix_flow
@distribution_consumption_fix_flow.setter
def distribution_consumption_fix_flow(self, value):
"""
Set distribution_consumption if the pump or fan work at fix mass or volume flow in ratio over peak power (W/W)
:return: float
"""
self._distribution_consumption_fix_flow = value
@property
def distribution_consumption_variable_flow(self):
"""
Get distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
over energy produced (J/J)
:return: float
"""
return self._distribution_consumption_variable_flow
@distribution_consumption_variable_flow.setter
def distribution_consumption_variable_flow(self, value):
"""
Set distribution_consumption if the pump or fan work at variable mass or volume flow in ratio
over energy produced (J/J)
:return: float
"""
self._distribution_consumption_variable_flow = value
@property
def heat_losses(self):
"""
Get heat_losses in ratio over energy produced
:return: float
"""
return self._heat_losses
@heat_losses.setter
def heat_losses(self, value):
"""
Set heat_losses in ratio over energy produced
:param value: float
"""
self._heat_losses = value

View File

@ -1,30 +0,0 @@
"""
Generic energy emission system module
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
class GenericEmissionSystem:
"""
GenericEmissionSystem class
"""
def __init__(self):
self._parasitic_energy_consumption = None
@property
def parasitic_energy_consumption(self):
"""
Get parasitic_energy_consumption in ratio (W/W)
:return: float
"""
return self._parasitic_energy_consumption
@parasitic_energy_consumption.setter
def parasitic_energy_consumption(self, value):
"""
Set parasitic_energy_consumption in ratio (W/W)
:param value: float
"""
self._parasitic_energy_consumption = value

View File

@ -1,105 +0,0 @@
"""
Generic energy system definition
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from typing import Union
from hub.city_model_structure.energy_systems.generic_distribution_system import GenericDistributionSystem
from hub.city_model_structure.energy_systems.generic_emission_system import GenericEmissionSystem
from hub.city_model_structure.energy_systems.generic_generation_system import GenericGenerationSystem
class GenericEnergySystem:
"""
GenericEnergySystem class
"""
def __init__(self):
self._name = None
self._demand_types = None
self._generation_system = None
self._distribution_system = None
self._emission_system = None
self._connected_city_objects = None
@property
def name(self):
"""
Get energy system name
:return: str
"""
return self._name
@name.setter
def name(self, value):
"""
Set energy system name
:param value:
"""
self._name = value
@property
def demand_types(self):
"""
Get demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
:return: [string]
"""
return self._demand_types
@demand_types.setter
def demand_types(self, value):
"""
Set demand able to cover from [Heating, Cooling, Domestic Hot Water, Electricity]
:param value: [string]
"""
self._demand_types = value
@property
def generation_system(self) -> GenericGenerationSystem:
"""
Get generation system
:return: GenerationSystem
"""
return self._generation_system
@generation_system.setter
def generation_system(self, value):
"""
Set generation system
:return: GenerationSystem
"""
self._generation_system = value
@property
def distribution_system(self) -> Union[None, GenericDistributionSystem]:
"""
Get distribution system
:return: DistributionSystem
"""
return self._distribution_system
@distribution_system.setter
def distribution_system(self, value):
"""
Set distribution system
:param value: DistributionSystem
"""
self._distribution_system = value
@property
def emission_system(self) -> Union[None, GenericEmissionSystem]:
"""
Get emission system
:return: EmissionSystem
"""
return self._emission_system
@emission_system.setter
def emission_system(self, value):
"""
Set emission system
:param value: EmissionSystem
"""
self._emission_system = value

View File

@ -1,186 +0,0 @@
"""
Generic energy generation system definition
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from __future__ import annotations
from typing import Union
class GenericGenerationSystem:
"""
GenericGenerationSystem class
"""
def __init__(self):
self._type = None
self._fuel_type = None
self._source_types = None
self._heat_efficiency = None
self._cooling_efficiency = None
self._electricity_efficiency = None
self._source_temperature = None
self._source_mass_flow = None
self._storage = None
self._auxiliary_equipment = None
@property
def type(self):
"""
Get system type
:return: string
"""
return self._type
@type.setter
def type(self, value):
"""
Set system type
:param value: string
"""
self._type = value
@property
def fuel_type(self):
"""
Get fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
:return: string
"""
return self._fuel_type
@fuel_type.setter
def fuel_type(self, value):
"""
Set fuel_type from [Renewable, Gas, Diesel, Electricity, Wood, Coal]
:param value: string
"""
self._fuel_type = value
@property
def source_types(self):
"""
Get source_type from [Air, Water, Geothermal, District Heating, Grid, Onsite Electricity]
:return: [string]
"""
return self._source_types
@source_types.setter
def source_types(self, value):
"""
Set source_type from [Air, Water, Geothermal, District Heating, Grid, Onsite Electricity]
:param value: [string]
"""
self._source_types = value
@property
def heat_efficiency(self):
"""
Get heat_efficiency
:return: float
"""
return self._heat_efficiency
@heat_efficiency.setter
def heat_efficiency(self, value):
"""
Set heat_efficiency
:param value: float
"""
self._heat_efficiency = value
@property
def cooling_efficiency(self):
"""
Get cooling_efficiency
:return: float
"""
return self._cooling_efficiency
@cooling_efficiency.setter
def cooling_efficiency(self, value):
"""
Set cooling_efficiency
:param value: float
"""
self._cooling_efficiency = value
@property
def electricity_efficiency(self):
"""
Get electricity_efficiency
:return: float
"""
return self._electricity_efficiency
@electricity_efficiency.setter
def electricity_efficiency(self, value):
"""
Set electricity_efficiency
:param value: float
"""
self._electricity_efficiency = value
@property
def source_temperature(self):
"""
Get source_temperature in degree Celsius
:return: float
"""
return self._source_temperature
@source_temperature.setter
def source_temperature(self, value):
"""
Set source_temperature in degree Celsius
:param value: float
"""
self._source_temperature = value
@property
def source_mass_flow(self):
"""
Get source_mass_flow in kg/s
:return: float
"""
return self._source_mass_flow
@source_mass_flow.setter
def source_mass_flow(self, value):
"""
Set source_mass_flow in kg/s
:param value: float
"""
self._source_mass_flow = value
@property
def storage(self):
"""
Get boolean storage exists
:return: bool
"""
return self._storage
@storage.setter
def storage(self, value):
"""
Set boolean storage exists
:return: bool
"""
self._storage = value
@property
def auxiliary_equipment(self) -> Union[None, GenericGenerationSystem]:
"""
Get auxiliary_equipment
:return: GenerationSystem
"""
return self._auxiliary_equipment
@auxiliary_equipment.setter
def auxiliary_equipment(self, value):
"""
Set auxiliary_equipment
:return: GenerationSystem
"""
self._auxiliary_equipment = value

View File

@ -1,64 +0,0 @@
"""
heat_pump module defines a heat pump
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Peter Yefi peteryefi@gmail.com
"""
from typing import List
from pandas.core.series import Series
class HeatPump:
"""
HeatPump class
"""
def __init__(self):
self._model = None
self._hp_monthly_fossil_consumption = None
self._hp_monthly_electricity_demand = None
@property
def model(self) -> str:
"""
Get model name
:return: str
"""
return self._model
@model.setter
def model(self, value):
"""
Set model (name, indicated in capacity)
:param value: str
"""
if self._model is None:
self._model = value
@property
def hp_monthly_fossil_consumption(self) -> List:
"""
Fossil fuel consumption that results from insel simulation
":return: []
:return:
"""
return self._hp_monthly_fossil_consumption
@hp_monthly_fossil_consumption.setter
def hp_monthly_fossil_consumption(self, value):
if isinstance(value, Series):
self._hp_monthly_fossil_consumption = value
@property
def hp_monthly_electricity_demand(self) -> List:
"""
Electricity demand that results from insel simulation
":return: []
:return:
"""
return self._hp_monthly_electricity_demand
@hp_monthly_electricity_demand.setter
def hp_monthly_electricity_demand(self, value):
if isinstance(value, Series):
self._hp_monthly_electricity_demand = value

View File

@ -1,32 +0,0 @@
"""
HvacTerminalUnit module
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from typing import Union
class HvacTerminalUnit:
"""
HvacTerminalUnit class
"""
def __init__(self):
self._type = None
@property
def type(self) -> Union[None, str]:
"""
Get type of hvac terminal unit defined for a thermal zone
:return: None or str
"""
return self._type
@type.setter
def type(self, value):
"""
Set type of hvac terminal unit defined for a thermal zone
:param value: str
"""
if value is not None:
self._type = str(value)

View File

@ -0,0 +1,539 @@
"""
Non PV energy generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from typing import Union
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
from hub.city_model_structure.energy_systems.performance_curve import PerformanceCurves
class NonPvGenerationSystem(GenerationSystem):
"""
NonPvGenerationSystem class
"""
def __init__(self):
super().__init__()
self._nominal_heat_output = None
self._maximum_heat_output = None
self._minimum_heat_output = None
self._heat_efficiency = None
self._nominal_cooling_output = None
self._maximum_cooling_output = None
self._minimum_cooling_output = None
self._cooling_efficiency = None
self._electricity_efficiency = None
self._nominal_electricity_output = None
self._source_medium = None
self._source_temperature = None
self._source_mass_flow = None
self._supply_medium = None
self._maximum_heat_supply_temperature = None
self._minimum_heat_supply_temperature = None
self._maximum_cooling_supply_temperature = None
self._minimum_cooling_supply_temperature = None
self._heat_output_curve = None
self._heat_fuel_consumption_curve = None
self._heat_efficiency_curve = None
self._cooling_output_curve = None
self._cooling_fuel_consumption_curve = None
self._cooling_efficiency_curve = None
self._domestic_hot_water = None
self._heat_supply_temperature = None
self._cooling_supply_temperature = None
self._reversible = None
self._simultaneous_heat_cold = None
self._energy_consumption = {}
@property
def nominal_heat_output(self):
"""
Get nominal heat output of heat generation devices in W
:return: float
"""
return self._nominal_heat_output
@nominal_heat_output.setter
def nominal_heat_output(self, value):
"""
Set nominal heat output of heat generation devices in W
:param value: float
"""
self._nominal_heat_output = value
@property
def maximum_heat_output(self):
"""
Get maximum heat output of heat generation devices in W
:return: float
"""
return self._maximum_heat_output
@maximum_heat_output.setter
def maximum_heat_output(self, value):
"""
Set maximum heat output of heat generation devices in W
:param value: float
"""
self._maximum_heat_output = value
@property
def minimum_heat_output(self):
"""
Get minimum heat output of heat generation devices in W
:return: float
"""
return self._minimum_heat_output
@minimum_heat_output.setter
def minimum_heat_output(self, value):
"""
Set minimum heat output of heat generation devices in W
:param value: float
"""
self._minimum_heat_output = value
@property
def source_medium(self):
"""
Get source_type from [air, water, ground, district_heating, grid, on_site_electricity]
:return: string
"""
return self._source_medium
@source_medium.setter
def source_medium(self, value):
"""
Set source medium from [Air, Water, Geothermal, District Heating, Grid, Onsite Electricity]
:param value: [string]
"""
self._source_medium = value
@property
def supply_medium(self):
"""
Get the supply medium from ['air', 'water']
:return: string
"""
return self._supply_medium
@supply_medium.setter
def supply_medium(self, value):
"""
Set the supply medium from ['air', 'water']
:param value: string
"""
self._supply_medium = value
@property
def heat_efficiency(self):
"""
Get heat_efficiency
:return: float
"""
return self._heat_efficiency
@heat_efficiency.setter
def heat_efficiency(self, value):
"""
Set heat_efficiency
:param value: float
"""
self._heat_efficiency = value
@property
def nominal_cooling_output(self):
"""
Get nominal cooling output of heat generation devices in W
:return: float
"""
return self._nominal_cooling_output
@nominal_cooling_output.setter
def nominal_cooling_output(self, value):
"""
Set nominal cooling output of heat generation devices in W
:param value: float
"""
self._nominal_cooling_output = value
@property
def maximum_cooling_output(self):
"""
Get maximum heat output of heat generation devices in W
:return: float
"""
return self._maximum_cooling_output
@maximum_cooling_output.setter
def maximum_cooling_output(self, value):
"""
Set maximum heat output of heat generation devices in W
:param value: float
"""
self._maximum_cooling_output = value
@property
def minimum_cooling_output(self):
"""
Get minimum heat output of heat generation devices in W
:return: float
"""
return self._minimum_cooling_output
@minimum_cooling_output.setter
def minimum_cooling_output(self, value):
"""
Set minimum heat output of heat generation devices in W
:param value: float
"""
self._minimum_cooling_output = value
@property
def cooling_efficiency(self):
"""
Get cooling_efficiency
:return: float
"""
return self._cooling_efficiency
@cooling_efficiency.setter
def cooling_efficiency(self, value):
"""
Set cooling_efficiency
:param value: float
"""
self._cooling_efficiency = value
@property
def electricity_efficiency(self):
"""
Get electricity_efficiency
:return: float
"""
return self._electricity_efficiency
@electricity_efficiency.setter
def electricity_efficiency(self, value):
"""
Set electricity_efficiency
:param value: float
"""
self._electricity_efficiency = value
@property
def source_temperature(self):
"""
Get source_temperature in degree Celsius
:return: float
"""
return self._source_temperature
@source_temperature.setter
def source_temperature(self, value):
"""
Set source_temperature in degree Celsius
:param value: float
"""
self._source_temperature = value
@property
def source_mass_flow(self):
"""
Get source_mass_flow in kg/s
:return: float
"""
return self._source_mass_flow
@source_mass_flow.setter
def source_mass_flow(self, value):
"""
Set source_mass_flow in kg/s
:param value: float
"""
self._source_mass_flow = value
@property
def nominal_electricity_output(self):
"""
Get nominal_power_output of electricity generation devices or inverters in W
:return: float
"""
return self._nominal_electricity_output
@nominal_electricity_output.setter
def nominal_electricity_output(self, value):
"""
Get nominal_power_output of electricity generation devices or inverters in W
:param value: float
"""
self._nominal_electricity_output = value
@property
def maximum_heat_supply_temperature(self):
"""
Get the maximum heat supply temperature in degree Celsius
:return: float
"""
return self._minimum_heat_supply_temperature
@maximum_heat_supply_temperature.setter
def maximum_heat_supply_temperature(self, value):
"""
Set maximum heating supply temperature in degree Celsius
:param value: float
"""
self._maximum_heat_supply_temperature = value
@property
def minimum_heat_supply_temperature(self):
"""
Get the minimum heat supply temperature in degree Celsius
:return: float
"""
return self._minimum_heat_supply_temperature
@minimum_heat_supply_temperature.setter
def minimum_heat_supply_temperature(self, value):
"""
Set minimum heating supply temperature in degree Celsius
:param value: float
"""
self._minimum_heat_supply_temperature = value
@property
def maximum_cooling_supply_temperature(self):
"""
Get the maximum cooling supply temperature in degree Celsius
:return: float
"""
return self._maximum_cooling_supply_temperature
@maximum_cooling_supply_temperature.setter
def maximum_cooling_supply_temperature(self, value):
"""
Set maximum cooling supply temperature in degree Celsius
:param value: float
"""
self._maximum_cooling_supply_temperature = value
@property
def minimum_cooling_supply_temperature(self):
"""
Get the minimum cooling supply temperature in degree Celsius
:return: float
"""
return self._minimum_cooling_supply_temperature
@minimum_cooling_supply_temperature.setter
def minimum_cooling_supply_temperature(self, value):
"""
Set minimum cooling supply temperature in degree Celsius
:param value: float
"""
self._minimum_cooling_supply_temperature = value
@property
def heat_output_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heat output curve of the heat generation device
:return: PerformanceCurve
"""
return self._heat_output_curve
@heat_output_curve.setter
def heat_output_curve(self, value):
"""
Set the heat output curve of the heat generation device
:return: PerformanceCurve
"""
self._heat_output_curve = value
@property
def heat_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating fuel consumption curve of the heat generation device
:return: PerformanceCurve
"""
return self._heat_fuel_consumption_curve
@heat_fuel_consumption_curve.setter
def heat_fuel_consumption_curve(self, value):
"""
Set the heating fuel consumption curve of the heat generation device
:return: PerformanceCurve
"""
self._heat_fuel_consumption_curve = value
@property
def heat_efficiency_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating efficiency curve of the heat generation device
:return: PerformanceCurve
"""
return self._heat_efficiency_curve
@heat_efficiency_curve.setter
def heat_efficiency_curve(self, value):
"""
Set the heating efficiency curve of the heat generation device
:return: PerformanceCurve
"""
self._heat_efficiency_curve = value
@property
def cooling_output_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heat output curve of the heat generation device
:return: PerformanceCurve
"""
return self._cooling_output_curve
@cooling_output_curve.setter
def cooling_output_curve(self, value):
"""
Set the cooling output curve of the heat generation device
:return: PerformanceCurve
"""
self._cooling_output_curve = value
@property
def cooling_fuel_consumption_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating fuel consumption curve of the heat generation device
:return: PerformanceCurve
"""
return self._cooling_fuel_consumption_curve
@cooling_fuel_consumption_curve.setter
def cooling_fuel_consumption_curve(self, value):
"""
Set the heating fuel consumption curve of the heat generation device
:return: PerformanceCurve
"""
self._cooling_fuel_consumption_curve = value
@property
def cooling_efficiency_curve(self) -> Union[None, PerformanceCurves]:
"""
Get the heating efficiency curve of the heat generation device
:return: PerformanceCurve
"""
return self._cooling_efficiency_curve
@cooling_efficiency_curve.setter
def cooling_efficiency_curve(self, value):
"""
Set the heating efficiency curve of the heat generation device
:return: PerformanceCurve
"""
self._cooling_efficiency_curve = value
@property
def domestic_hot_water(self):
"""
Get the capability of generating domestic hot water
:return: bool
"""
return self._domestic_hot_water
@domestic_hot_water.setter
def domestic_hot_water(self, value):
"""
Set the capability of generating domestic hot water
:return: bool
"""
self._domestic_hot_water = value
@property
def heat_supply_temperature(self):
"""
Get the hourly heat supply temperature
:return: list
"""
return self._heat_supply_temperature
@heat_supply_temperature.setter
def heat_supply_temperature(self, value):
"""
set the hourly heat supply temperature
:param value:
:return: list
"""
self._heat_supply_temperature = value
@property
def cooling_supply_temperature(self):
"""
Get the hourly cooling supply temperature
:return: list
"""
return self._heat_supply_temperature
@cooling_supply_temperature.setter
def cooling_supply_temperature(self, value):
"""
set the hourly cooling supply temperature
:param value:
:return: list
"""
self._cooling_supply_temperature = value
@property
def reversibility(self):
"""
Get the capability of generating both heating and cooling
:return: bool
"""
return self._reversible
@reversibility.setter
def reversibility(self, value):
"""
Set the capability of generating domestic hot water
:return: bool
"""
self._reversible = value
@property
def simultaneous_heat_cold(self):
"""
Get the capability of generating both heating and cooling at the same time
:return: bool
"""
return self._simultaneous_heat_cold
@simultaneous_heat_cold.setter
def simultaneous_heat_cold(self, value):
"""
Set the capability of generating domestic hot water at the same time
:return: bool
"""
self._simultaneous_heat_cold = value
@property
def energy_consumption(self) -> dict:
"""
Get energy consumption in W
:return: dict{[float]}
"""
return self._energy_consumption
@energy_consumption.setter
def energy_consumption(self, value):
"""
Set energy consumption in W
:param value: dict{[float]}
"""
self._energy_consumption = value

View File

@ -0,0 +1,104 @@
"""
Energy System catalog heat generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Saeed Ranjbar saeed.ranjbar@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
"""
from __future__ import annotations
class PerformanceCurves:
"""
Parameter function class
"""
def __init__(self):
self._curve_type = None
self._dependant_variable = None
self._parameters = None
self._coefficients = None
@property
def curve_type(self):
"""
Get the type of the fit function from the following
Linear =>>> y = a + b*x
Exponential =>>> y = a*(b**x)
Second degree polynomial =>>> y = a + b*x + c*(x**2)
Power =>>> y = a*(x**b)
Bi-Quadratic =>>> y = a + b*x + c*(x**2) + d*z + e*(z**2) + f*x*z
Get the type of function from ['linear', 'exponential', 'second degree polynomial', 'power', 'bi-quadratic']
:return: string
"""
return self._curve_type
@curve_type.setter
def curve_type(self, value):
"""
Set the type of the fit function from the following
Linear =>>> y = a + b*x
Exponential =>>> y = a*(b**x)
Second degree polynomial =>>> y = a + b*x + c*(x**2)
Power =>>> y = a*(x**b)
Bi-Quadratic =>>> y = a + b*x + c*(x**2) + d*z + e*(z**2) + f*x*z
Get the type of function from ['linear', 'exponential', 'second degree polynomial', 'power', 'bi-quadratic']
:return: string
"""
self._curve_type = value
@property
def dependant_variable(self):
"""
Get y (e.g. COP in COP = a*source temperature**2 + b*source temperature + c*source temperature*supply temperature +
d*supply temperature + e*supply temperature**2 + f)
"""
return self._dependant_variable
@dependant_variable.setter
def dependant_variable(self, value):
"""
Set y (e.g. COP in COP = a*source temperature**2 + b*source temperature + c*source temperature*supply temperature +
d*supply temperature + e*supply temperature**2 + f)
"""
self._dependant_variable = value
@property
def parameters(self):
"""
Get the list of parameters involved in fitting process as ['x', 'z'] (e.g. [source temperature, supply temperature]
in COP= *source temperature**2 + b*source temperature + c*source temperature*supply temperature +
d*supply temperature + e*supply temperature**2 + f)
:return: string
"""
return self._parameters
@parameters.setter
def parameters(self, value):
"""
Set the list of parameters involved in fitting process as ['x', 'z'] (e.g. [source temperature, supply temperature]
in COP= *source temperature**2 + b*source temperature + c*source temperature*supply temperature +
d*supply temperature + e*supply temperature**2 + f)
:return: string
"""
self._parameters = value
@property
def coefficients(self):
"""
Get the coefficients of the functions as list of ['a', 'b', 'c', 'd', 'e', 'f']
:return: [coefficients]
"""
return self._coefficients
@coefficients.setter
def coefficients(self, value):
"""
Set the coefficients of the functions as list of ['a', 'b', 'c', 'd', 'e', 'f']
:return: [coefficients]
"""
self._coefficients = value

View File

@ -0,0 +1,239 @@
"""
PV energy generation system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from hub.city_model_structure.energy_systems.generation_system import GenerationSystem
class PvGenerationSystem(GenerationSystem):
"""
PvGenerationSystem class
"""
def __init__(self):
super().__init__()
self._electricity_efficiency = None
self._nominal_electricity_output = None
self._nominal_ambient_temperature = None
self._nominal_cell_temperature = None
self._nominal_radiation = None
self._standard_test_condition_cell_temperature = None
self._standard_test_condition_maximum_power = None
self._standard_test_condition_radiation = None
self._cell_temperature_coefficient = None
self._width = None
self._height = None
self._electricity_power_output = {}
self._tilt_angle = None
self._installed_capacity = None
@property
def nominal_electricity_output(self):
"""
Get nominal_power_output of electricity generation devices or inverters in W
:return: float
"""
return self._nominal_electricity_output
@nominal_electricity_output.setter
def nominal_electricity_output(self, value):
"""
Set nominal_power_output of electricity generation devices or inverters in W
:param value: float
"""
self._nominal_electricity_output = value
@property
def electricity_efficiency(self):
"""
Get electricity_efficiency
:return: float
"""
return self._electricity_efficiency
@electricity_efficiency.setter
def electricity_efficiency(self, value):
"""
Set electricity_efficiency
:param value: float
"""
self._electricity_efficiency = value
@property
def nominal_ambient_temperature(self):
"""
Get nominal ambient temperature of PV panels in degree Celsius
:return: float
"""
return self._nominal_ambient_temperature
@nominal_ambient_temperature.setter
def nominal_ambient_temperature(self, value):
"""
Set nominal ambient temperature of PV panels in degree Celsius
:param value: float
"""
self._nominal_ambient_temperature = value
@property
def nominal_cell_temperature(self):
"""
Get nominal cell temperature of PV panels in degree Celsius
:return: float
"""
return self._nominal_cell_temperature
@nominal_cell_temperature.setter
def nominal_cell_temperature(self, value):
"""
Set nominal cell temperature of PV panels in degree Celsius
:param value: float
"""
self._nominal_cell_temperature = value
@property
def nominal_radiation(self):
"""
Get nominal radiation of PV panels
:return: float
"""
return self._nominal_radiation
@nominal_radiation.setter
def nominal_radiation(self, value):
"""
Set nominal radiation of PV panels
:param value: float
"""
self._nominal_radiation = value
@property
def standard_test_condition_cell_temperature(self):
"""
Get standard test condition cell temperature of PV panels in degree Celsius
:return: float
"""
return self._standard_test_condition_cell_temperature
@standard_test_condition_cell_temperature.setter
def standard_test_condition_cell_temperature(self, value):
"""
Set standard test condition cell temperature of PV panels in degree Celsius
:param value: float
"""
self._standard_test_condition_cell_temperature = value
@property
def standard_test_condition_maximum_power(self):
"""
Get standard test condition maximum power of PV panels in W
:return: float
"""
return self._standard_test_condition_maximum_power
@standard_test_condition_maximum_power.setter
def standard_test_condition_maximum_power(self, value):
"""
Set standard test condition maximum power of PV panels in W
:param value: float
"""
self._standard_test_condition_maximum_power = value
@property
def standard_test_condition_radiation(self):
"""
Get standard test condition radiation in W/m2
:return: float
"""
return self._standard_test_condition_radiation
@standard_test_condition_radiation.setter
def standard_test_condition_radiation(self, value):
"""
Set standard test condition radiation in W/m2
:param value: float
"""
self._standard_test_condition_radiation = value
@property
def cell_temperature_coefficient(self):
"""
Get cell temperature coefficient of PV module
:return: float
"""
return self._cell_temperature_coefficient
@cell_temperature_coefficient.setter
def cell_temperature_coefficient(self, value):
"""
Set cell temperature coefficient of PV module
:param value: float
"""
self._cell_temperature_coefficient = value
@property
def width(self):
"""
Get PV module width in m
:return: float
"""
return self._width
@width.setter
def width(self, value):
"""
Set PV module width in m
:param value: float
"""
self._width = value
@property
def height(self):
"""
Get PV module height in m
:return: float
"""
return self._height
@height.setter
def height(self, value):
"""
Set PV module height in m
:param value: float
"""
self._height = value
@property
def electricity_power_output(self):
"""
Get electricity_power in W
:return: float
"""
return self._electricity_power_output
@electricity_power_output.setter
def electricity_power_output(self, value):
"""
Set electricity_power in W
:param value: float
"""
self._electricity_power_output = value
@property
def installed_capacity(self):
"""
Get the total installed nominal capacity in W
:return: float
"""
return self._installed_capacity
@installed_capacity.setter
def installed_capacity(self, value):
"""
Set the total installed nominal capacity in W
:param value: float
"""
self._installed_capacity = value

View File

@ -0,0 +1,139 @@
"""
Thermal storage system
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2023 Concordia CERC group
Project Coder Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Code contributors: Saeed Ranjbar saeed.ranjbar@concordia.ca
"""
from hub.city_model_structure.energy_systems.energy_storage_system import EnergyStorageSystem
from hub.city_model_structure.building_demand.layer import Layer
class ThermalStorageSystem(EnergyStorageSystem):
""""
Thermal Storage System Class
"""
def __init__(self):
super().__init__()
self._volume = None
self._height = None
self._layers = None
self._maximum_operating_temperature = None
self._heating_coil_capacity = None
self._temperature = None
self._heating_coil_energy_consumption = None
@property
def volume(self):
"""
Get the physical volume of the storage system in cubic meters
:return: float
"""
return self._volume
@volume.setter
def volume(self, value):
"""
Set the physical volume of the storage system in cubic meters
:param value: float
"""
self._volume = value
@property
def height(self):
"""
Get the diameter of the storage system in meters
:return: float
"""
return self._height
@height.setter
def height(self, value):
"""
Set the diameter of the storage system in meters
:param value: float
"""
self._height = value
@property
def layers(self) -> [Layer]:
"""
Get construction layers
:return: [layer]
"""
return self._layers
@layers.setter
def layers(self, value):
"""
Set construction layers
:param value: [layer]
"""
self._layers = value
@property
def maximum_operating_temperature(self):
"""
Get maximum operating temperature of the storage system in degree Celsius
:return: float
"""
return self._maximum_operating_temperature
@maximum_operating_temperature.setter
def maximum_operating_temperature(self, value):
"""
Set maximum operating temperature of the storage system in degree Celsius
:param value: float
"""
self._maximum_operating_temperature = value
@property
def heating_coil_capacity(self):
"""
Get heating coil capacity in Watts
:return: float
"""
return self._heating_coil_capacity
@heating_coil_capacity.setter
def heating_coil_capacity(self, value):
"""
Set heating coil capacity in Watts
:param value: float
"""
self._heating_coil_capacity = value
@property
def temperature(self) -> dict:
"""
Get fuel consumption in W, m3, or kg
:return: dict{[float]}
"""
return self._temperature
@temperature.setter
def temperature(self, value):
"""
Set fuel consumption in W, m3, or kg
:param value: dict{[float]}
"""
self._temperature = value
@property
def heating_coil_energy_consumption(self) -> dict:
"""
Get fuel consumption in W, m3, or kg
:return: dict{[float]}
"""
return self._heating_coil_energy_consumption
@heating_coil_energy_consumption.setter
def heating_coil_energy_consumption(self, value):
"""
Set fuel consumption in W, m3, or kg
:param value: dict{[float]}
"""
self._heating_coil_energy_consumption = value

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,774 @@
{
"archetypes": [
{
"function": "Large multifamily building",
"period_of_construction": "2021_2050",
"climate_zone": "B3",
"average_storey_height": 3.57,
"thermal_capacity": 83.018,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0005,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT",
"transparent_surface_name": "PA1_PA2_2021_2050_WIN1",
"transparent_ratio": {
"north": "60",
"east": "5",
"south": "60",
"west": "5"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_ROOF",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOOR"
},
"GroundWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT"
},
"GroundRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOORINT"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "2021_2050",
"climate_zone": "B3",
"average_storey_height": 3.57,
"thermal_capacity": 83.018,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0005,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT",
"transparent_surface_name": "PA1_PA2_2021_2050_WIN1",
"transparent_ratio": {
"north": "60",
"east": "5",
"south": "60",
"west": "5"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_ROOF",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOOR"
},
"GroundWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT"
},
"GroundRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOORINT"
}
}
},
{
"function": "Small multifamily building",
"period_of_construction": "2021_2050",
"climate_zone": "B3",
"average_storey_height": 3.57,
"thermal_capacity": 83.018,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0005,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT",
"transparent_surface_name": "PA1_PA2_2021_2050_WIN1",
"transparent_ratio": {
"north": "60",
"east": "5",
"south": "60",
"west": "5"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_ROOF",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOOR"
},
"GroundWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT"
},
"GroundRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOORINT"
}
}
},
{
"function": "Single-family building",
"period_of_construction": "2021_2050",
"climate_zone": "B3",
"average_storey_height": 3.57,
"thermal_capacity": 83.018,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0005,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT",
"transparent_surface_name": "PA1_PA2_2021_2050_WIN1",
"transparent_ratio": {
"north": "60",
"east": "5",
"south": "60",
"west": "5"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_ROOF",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOOR"
},
"GroundWall": {
"opaque_surface_name": "PA1_PA2_2021_2050_FACEXT"
},
"GroundRoofCeiling": {
"opaque_surface_name": "PA1_PA2_2021_2050_FLOORINT"
}
}
},
{
"function": "Large multifamily building",
"period_of_construction": "1961_1980",
"climate_zone": "B3",
"average_storey_height": 3.57,
"thermal_capacity": 3000,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0045,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA1_PA2_1961_1980_FACEXT1",
"transparent_surface_name": "PA1_PA2_1961_1980_WIN1",
"transparent_ratio": {
"north": "60",
"east": "60",
"south": "60",
"west": "60"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA1_PA2_1961_1980_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA1_PA2_1961_1980_FLOOR1"
},
"GroundWall": {
"opaque_surface_name": "PA1_PA2_1961_1980_FACEXT1"
},
"GroundRoofCeiling": {
"opaque_surface_name": "PA1_PA2_1961_1980_FLOOR4"
}
}
},
{
"function": "Large multifamily building",
"period_of_construction": "1981_2007",
"climate_zone": "B3",
"average_storey_height": 3.2,
"thermal_capacity": 3179,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.003,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "E_1981_2007_FACEXT1",
"transparent_surface_name": "E_1981_2007_WIN1",
"transparent_ratio": {
"north": "45",
"east": "45",
"south": "45",
"west": "45"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "E_1981_2007_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "E_1981_2007_FLOORGR1"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "1800_1900",
"climate_zone": "B3",
"average_storey_height": 4.39,
"thermal_capacity": 3330,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.006,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "A_B1900_FACEXT1",
"transparent_surface_name": "A_B1900_WIN2",
"transparent_ratio": {
"north": "20",
"east": "20",
"south": "20",
"west": "20"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "A_B1900_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "A_B1900_FLOORGR1"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "1901_1940",
"climate_zone": "B3",
"average_storey_height": 3.65,
"thermal_capacity": 3420,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.006,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "B_1901_1940_FACEXT1",
"transparent_surface_name": "B_1901_1940_WIN1",
"transparent_ratio": {
"north": "40",
"east": "40",
"south": "40",
"west": "40"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "B_1901_1940_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "B_1901_1940_FLOORGR1"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "1941_1960",
"climate_zone": "B3",
"average_storey_height": 3.6,
"thermal_capacity": 3000,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0055,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "C_1941_1960_FACEXT1",
"transparent_surface_name": "C_1941_1960_WIN1",
"transparent_ratio": {
"north": "30",
"east": "30",
"south": "30",
"west": "30"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "C_1941_1960_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "C_1941_1960_FLOORGR1"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "1961_1980",
"climate_zone": "B3",
"average_storey_height": 4.5,
"thermal_capacity": 3540,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0045,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA1_PA2_1961_1980_FACEXT1",
"transparent_surface_name": "PA1_PA2_1961_1980_WIN1",
"transparent_ratio": {
"north": "55",
"east": "55",
"south": "55",
"west": "55"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA1_PA2_1961_1980_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA1_PA2_1961_1980_FLOOR1"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "1981_2007",
"climate_zone": "B3",
"average_storey_height": 3.2,
"thermal_capacity": 3179,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.003,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "E_1981_2007_FACEXT1",
"transparent_surface_name": "E_1981_2007_WIN1",
"transparent_ratio": {
"north": "45",
"east": "45",
"south": "45",
"west": "45"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "E_1981_2007_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "E_1981_2007_FLOORGR1"
}
}
},
{
"function": "Medium multifamily building",
"period_of_construction": "2008_2014",
"climate_zone": "B3",
"average_storey_height": 2.75,
"thermal_capacity": 3290,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0015,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "F_2008_2014_FACEXT1",
"transparent_surface_name": "F_2008_2014_WIN1",
"transparent_ratio": {
"north": "40",
"east": "40",
"south": "40",
"west": "40"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "F_2008_2014_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "F_2008_2014_FLOORGR1"
}
}
},
{
"function": "Small multifamily building",
"period_of_construction": "1800_1980",
"climate_zone": "B3",
"average_storey_height": 3.8,
"thermal_capacity": 3527.9,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.006,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA3_PA4_1901_1940_FACEXT1",
"transparent_surface_name": "PA3_PA4_1901_1940_WIN1",
"transparent_ratio": {
"north": "40",
"east": "40",
"south": "40",
"west": "40"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA3_PA4_1901_1940_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA3_PA4_1901_1940_FLOORGR1"
}
}
},
{
"function": "Small multifamily building",
"period_of_construction": "1981_2007",
"climate_zone": "B3",
"average_storey_height": 3.2,
"thermal_capacity": 3179,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.003,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "E_1981_2007_FACEXT1",
"transparent_surface_name": "E_1981_2007_WIN1",
"transparent_ratio": {
"north": "45",
"east": "45",
"south": "45",
"west": "45"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "E_1981_2007_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "E_1981_2007_FLOORGR1"
}
}
},
{
"function": "Small multifamily building",
"period_of_construction": "2008_2014",
"climate_zone": "B3",
"average_storey_height": 2.75,
"thermal_capacity": 3290,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0015,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "F_2008_2014_FACEXT1",
"transparent_surface_name": "F_2008_2014_WIN1",
"transparent_ratio": {
"north": "40",
"east": "40",
"south": "40",
"west": "40"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "F_2008_2014_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "F_2008_2014_FLOORGR1"
}
}
},
{
"function": "Small multifamily building",
"period_of_construction": "2015_2019",
"climate_zone": "B3",
"average_storey_height": 2.75,
"thermal_capacity": 3290,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0005,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "G_2015_2019_FACEXT1",
"transparent_surface_name": "G_2015_2019_WIN1",
"transparent_ratio": {
"north": "40",
"east": "40",
"south": "40",
"west": "40"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "G_2015_2019_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "G_2015_2019_FLOORGR1"
}
}
},
{
"function": "Single-family building",
"period_of_construction": "1800_1980",
"climate_zone": "B3",
"average_storey_height": 3.68,
"thermal_capacity": 4400,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.006,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "PA3_PA4_1901_1940_FACEXT1",
"transparent_surface_name": "PA3_PA4_1901_1940_WIN1",
"transparent_ratio": {
"north": "40",
"east": "40",
"south": "40",
"west": "40"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "PA3_PA4_1901_1940_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "PA3_PA4_1901_1940_FLOORGR1"
}
}
},
{
"function": "Single-family building",
"period_of_construction": "1981_2007",
"climate_zone": "B3",
"average_storey_height": 3.2,
"thermal_capacity": 3179,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.003,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "E_1981_2007_FACEXT1",
"transparent_surface_name": "E_1981_2007_WIN1",
"transparent_ratio": {
"north": "45",
"east": "45",
"south": "45",
"west": "45"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "E_1981_2007_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "E_1981_2007_FLOORGR1"
}
}
},
{
"function": "Single-family building",
"period_of_construction": "2008_2014",
"climate_zone": "B3",
"average_storey_height": 3.75,
"thermal_capacity": 3200,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0015,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "F_2008_2014_FACEXT1",
"transparent_surface_name": "F_2008_2014_WIN1",
"transparent_ratio": {
"north": "60",
"east": "60",
"south": "60",
"west": "60"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "F_2008_2014_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "F_2008_2014_FLOORGR1"
}
}
},
{
"function": "Single-family building",
"period_of_construction": "2015_2019",
"climate_zone": "B3",
"average_storey_height": 3.75,
"thermal_capacity": 3200,
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.0005,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "G_2015_2019_FACEXT1",
"transparent_surface_name": "G_2015_2019_WIN1",
"transparent_ratio": {
"north": "60",
"east": "60",
"south": "60",
"west": "60"
}
},
"OutdoorsRoofCeiling": {
"opaque_surface_name": "G_2015_2019_ROOF1",
"transparent_surface_name": null,
"transparent_ratio": {
"north": null,
"east": null,
"south": null,
"west": null
}
},
"GroundFloor": {
"opaque_surface_name": "G_2015_2019_FLOORGR1"
}
}
}
]
}

File diff suppressed because it is too large Load Diff

View File

@ -38,53 +38,96 @@
</equipment>
</generation_equipments>
<distribution_equipments>
<equipment id="1" type="Water distribution heating">
<equipment id="1" type="Water distribution heating with baseboards">
<name>Water distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>1</dissipation_id>
</equipment>
<equipment id="2" type="Water distribution cooling">
<equipment id="2" type="Water distribution heating with fan-coils">
<name>Water distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="3" type="Water distribution heating with inductors">
<name>Water distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">2</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="4" type="Water distribution cooling with fan-coils">
<name>Water distribution cooling</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">4</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="3" type="Central air distribution heating">
<equipment id="5" type="Central air distribution heating with fan-coils">
<name>Central air distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="4" type="Central air distribution cooling">
<equipment id="6" type="Central air distribution heating with inductors">
<name>Central air distribution heating</name>
<distribution_heat_losses units="%">10</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="7" type="Central air distribution cooling with fan-coils">
<name>Central air distribution cooling</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">13</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="5" type="Local air distribution heating">
<equipment id="8" type="Local air distribution heating with baseboards">
<name>Local air distribution heating</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>1</dissipation_id>
</equipment>
<equipment id="6" type="Local air distribution cooling">
<equipment id="9" type="Local air distribution heating with inductors">
<name>Local air distribution heating</name>
<distribution_heat_losses units="%">5</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="10" type="Local air distribution cooling with inductors">
<name>Local air distribution cooling</name>
<distribution_heat_losses units="%">2</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">8</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
<equipment id="7" type="Refrigerant distribution">
<equipment id="11" type="Refrigerant distribution with fan-coils">
<name>Refrigerant distribution</name>
<distribution_heat_losses units="%">1</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">1</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>2</dissipation_id>
</equipment>
<equipment id="8" type="No distribution">
<equipment id="12" type="No distribution with baseboards">
<name>No distribution</name>
<distribution_heat_losses units="%">0</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>1</dissipation_id>
</equipment>
<equipment id="13" type="No distribution with inductors">
<name>No distribution</name>
<distribution_heat_losses units="%">0</distribution_heat_losses>
<distribution_consumption_fix_flow units="%">0</distribution_consumption_fix_flow>
<distribution_consumption_variable_flow units="%">0</distribution_consumption_variable_flow>
<dissipation_id>3</dissipation_id>
</equipment>
</distribution_equipments>
<dissipation_equipments>
@ -111,7 +154,6 @@
<equipments>
<generation_id>1</generation_id>
<distribution_id>1</distribution_id>
<dissipation_id>1</dissipation_id>
</equipments>
</system>
<system id = "16">
@ -122,8 +164,7 @@
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>8</distribution_id>
<dissipation_id>1</dissipation_id>
<distribution_id>12</distribution_id>
</equipments>
</system>
<system id = "2">
@ -134,8 +175,7 @@
</demands>
<equipments>
<generation_id>1</generation_id>
<distribution_id>1</distribution_id>
<dissipation_id>2</dissipation_id>
<distribution_id>2</distribution_id>
</equipments>
</system>
<system id="3">
@ -146,8 +186,7 @@
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>1</distribution_id>
<dissipation_id>2</dissipation_id>
<distribution_id>2</distribution_id>
</equipments>
</system>
<system id="4">
@ -158,8 +197,7 @@
</demands>
<equipments>
<generation_id>3</generation_id>
<distribution_id>5</distribution_id>
<dissipation_id>1</dissipation_id>
<distribution_id>8</distribution_id>
</equipments>
</system>
<system id="5">
@ -170,8 +208,7 @@
</demands>
<equipments>
<generation_id>4</generation_id>
<distribution_id>5</distribution_id>
<dissipation_id>1</dissipation_id>
<distribution_id>8</distribution_id>
</equipments>
</system>
<system id="6">
@ -183,7 +220,6 @@
<equipments>
<generation_id>1</generation_id>
<distribution_id>1</distribution_id>
<dissipation_id>1</dissipation_id>
</equipments>
</system>
<system id="7">
@ -194,8 +230,7 @@
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>8</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>13</distribution_id>
</equipments>
</system>
<system id="8">
@ -205,9 +240,8 @@
<demand>domestic_hot_water</demand>
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>1</distribution_id>
<dissipation_id>3</dissipation_id>
<generation_id>1</generation_id>
<distribution_id>3</distribution_id>
</equipments>
</system>
<system id="9">
@ -218,8 +252,7 @@
</demands>
<equipments>
<generation_id>2</generation_id>
<distribution_id>8</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>13</distribution_id>
</equipments>
</system>
<system id="10">
@ -229,8 +262,7 @@
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>6</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>10</distribution_id>
</equipments>
</system>
<system id="11">
@ -240,8 +272,7 @@
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>2</distribution_id>
<dissipation_id>2</dissipation_id>
<distribution_id>4</distribution_id>
</equipments>
</system>
<system id="12">
@ -251,8 +282,7 @@
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>6</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>10</distribution_id>
</equipments>
</system>
<system id="13">
@ -262,8 +292,7 @@
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>6</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>10</distribution_id>
</equipments>
</system>
<system id="14">
@ -273,8 +302,7 @@
</demands>
<equipments>
<generation_id>5</generation_id>
<distribution_id>3</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>4</distribution_id>
</equipments>
</system>
<system id="15">
@ -284,8 +312,7 @@
</demands>
<equipments>
<generation_id>6</generation_id>
<distribution_id>5</distribution_id>
<dissipation_id>3</dissipation_id>
<distribution_id>9</distribution_id>
</equipments>
</system>
<system id="17">
@ -296,8 +323,7 @@
</demands>
<equipments>
<generation_id>7</generation_id>
<distribution_id>3</distribution_id>
<dissipation_id>2</dissipation_id>
<distribution_id>5</distribution_id>
</equipments>
</system>
<system id="18">
@ -307,8 +333,7 @@
</demands>
<equipments>
<generation_id>7</generation_id>
<distribution_id>4</distribution_id>
<dissipation_id>2</dissipation_id>
<distribution_id>7</distribution_id>
</equipments>
</system>
</systems>

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,809 @@
<?xml version="1.0" encoding="UTF-8"?>
<EnergySystemCatalog>
<schemas_path>./schemas/</schemas_path>
<media>
<medium>
<medium_id>1</medium_id>
<name>Water</name>
<solar_absorptance/>
<thermal_absorptance/>
<visible_absorptance/>
<no_mass/>
<thermal_resistance/>
<density>981.0</density>
<specific_heat>4180.0</specific_heat>
<conductivity>0.6</conductivity>
</medium>
</media>
<energy_generation_components>
<non_pv_generation_component>
<system_id>1</system_id>
<name>Natural-Gas Boiler</name>
<system_type>boiler</system_type>
<model_name/>
<manufacturer/>
<nominal_heat_output/>
<minimum_heat_output/>
<maximum_heat_output/>
<heat_efficiency>0.7</heat_efficiency>
<reversible>False</reversible>
<fuel_type>natural gas</fuel_type>
<source_medium/>
<supply_medium/>
<nominal_cooling_output/>
<minimum_cooling_output/>
<maximum_cooling_output/>
<cooling_efficiency/>
<electricity_efficiency/>
<source_temperature/>
<source_mass_flow/>
<nominal_electricity_output/>
<maximum_heat_supply_temperature/>
<minimum_heat_supply_temperature/>
<maximum_cooling_supply_temperature/>
<minimum_cooling_supply_temperature/>
<heat_output_curve/>
<heat_fuel_consumption_curve/>
<heat_efficiency_curve/>
<cooling_output_curve/>
<cooling_fuel_consumption_curve/>
<cooling_efficiency_curve/>
<distribution_systems/>
<energy_storage_systems/>
<domestic_hot_water>True</domestic_hot_water>
<heat_supply_temperature/>
<cooling_supply_temperature/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</non_pv_generation_component>
<non_pv_generation_component>
<system_id>2</system_id>
<name>Joule</name>
<system_type>joule</system_type>
<model_name/>
<manufacturer/>
<nominal_heat_output/>
<minimum_heat_output/>
<maximum_heat_output/>
<heat_efficiency>1</heat_efficiency>
<reversible>False</reversible>
<fuel_type>electricity</fuel_type>
<source_medium/>
<supply_medium/>
<nominal_cooling_output/>
<minimum_cooling_output/>
<maximum_cooling_output/>
<cooling_efficiency/>
<electricity_efficiency/>
<source_temperature/>
<source_mass_flow/>
<nominal_electricity_output/>
<maximum_heat_supply_temperature/>
<minimum_heat_supply_temperature/>
<maximum_cooling_supply_temperature/>
<minimum_cooling_supply_temperature/>
<heat_output_curve/>
<heat_fuel_consumption_curve/>
<heat_efficiency_curve/>
<cooling_output_curve/>
<cooling_fuel_consumption_curve/>
<cooling_efficiency_curve/>
<distribution_systems/>
<energy_storage_systems/>
<domestic_hot_water>True</domestic_hot_water>
<heat_supply_temperature/>
<cooling_supply_temperature/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</non_pv_generation_component>
<non_pv_generation_component>
<system_id>3</system_id>
<name>Heat Pump</name>
<system_type>heat pump</system_type>
<model_name/>
<manufacturer/>
<nominal_heat_output/>
<minimum_heat_output/>
<maximum_heat_output/>
<heat_efficiency>2</heat_efficiency>
<reversible>True</reversible>
<fuel_type>electricity</fuel_type>
<source_medium>Air</source_medium>
<supply_medium>Water</supply_medium>
<nominal_cooling_output/>
<minimum_cooling_output/>
<maximum_cooling_output/>
<cooling_efficiency>2</cooling_efficiency>
<electricity_efficiency/>
<source_temperature/>
<source_mass_flow/>
<nominal_electricity_output/>
<maximum_heat_supply_temperature/>
<minimum_heat_supply_temperature/>
<maximum_cooling_supply_temperature/>
<minimum_cooling_supply_temperature/>
<heat_output_curve/>
<heat_fuel_consumption_curve/>
<heat_efficiency_curve/>
<cooling_output_curve/>
<cooling_fuel_consumption_curve/>
<cooling_efficiency_curve/>
<distribution_systems/>
<energy_storage_systems/>
<domestic_hot_water>False</domestic_hot_water>
<heat_supply_temperature/>
<cooling_supply_temperature/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</non_pv_generation_component>
<non_pv_generation_component>
<system_id>4</system_id>
<name>Butane Heater</name>
<system_type>butane heater</system_type>
<model_name/>
<manufacturer/>
<nominal_heat_output/>
<minimum_heat_output/>
<maximum_heat_output/>
<heat_efficiency>0.7</heat_efficiency>
<reversible>False</reversible>
<fuel_type>butane</fuel_type>
<source_medium/>
<supply_medium/>
<nominal_cooling_output/>
<minimum_cooling_output/>
<maximum_cooling_output/>
<cooling_efficiency/>
<electricity_efficiency/>
<source_temperature/>
<source_mass_flow/>
<nominal_electricity_output/>
<maximum_heat_supply_temperature/>
<minimum_heat_supply_temperature/>
<maximum_cooling_supply_temperature/>
<minimum_cooling_supply_temperature/>
<heat_output_curve/>
<heat_fuel_consumption_curve/>
<heat_efficiency_curve/>
<cooling_output_curve/>
<cooling_fuel_consumption_curve/>
<cooling_efficiency_curve/>
<distribution_systems/>
<energy_storage_systems/>
<domestic_hot_water>True</domestic_hot_water>
<heat_supply_temperature/>
<cooling_supply_temperature/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</non_pv_generation_component>
<non_pv_generation_component>
<system_id>5</system_id>
<name>Split</name>
<system_type>split</system_type>
<model_name/>
<manufacturer/>
<nominal_heat_output/>
<minimum_heat_output/>
<maximum_heat_output/>
<heat_efficiency/>
<reversible>False</reversible>
<fuel_type>electricity</fuel_type>
<source_medium/>
<supply_medium/>
<nominal_cooling_output/>
<minimum_cooling_output/>
<maximum_cooling_output/>
<cooling_efficiency>2</cooling_efficiency>
<electricity_efficiency/>
<source_temperature/>
<source_mass_flow/>
<nominal_electricity_output/>
<maximum_heat_supply_temperature/>
<minimum_heat_supply_temperature/>
<maximum_cooling_supply_temperature/>
<minimum_cooling_supply_temperature/>
<heat_output_curve/>
<heat_fuel_consumption_curve/>
<heat_efficiency_curve/>
<cooling_output_curve/>
<cooling_fuel_consumption_curve/>
<cooling_efficiency_curve/>
<distribution_systems/>
<energy_storage_systems/>
<domestic_hot_water>False</domestic_hot_water>
<heat_supply_temperature/>
<cooling_supply_temperature/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</non_pv_generation_component>
<non_pv_generation_component>
<system_id>6</system_id>
<name>Domestic Hot Water Heat Pump</name>
<system_type>heat pump</system_type>
<model_name/>
<manufacturer/>
<nominal_heat_output/>
<minimum_heat_output/>
<maximum_heat_output/>
<heat_efficiency>3</heat_efficiency>
<reversible>False</reversible>
<fuel_type>electricity</fuel_type>
<source_medium>Air</source_medium>
<supply_medium>Water</supply_medium>
<nominal_cooling_output/>
<minimum_cooling_output/>
<maximum_cooling_output/>
<cooling_efficiency/>
<electricity_efficiency/>
<source_temperature/>
<source_mass_flow/>
<nominal_electricity_output/>
<maximum_heat_supply_temperature/>
<minimum_heat_supply_temperature/>
<maximum_cooling_supply_temperature/>
<minimum_cooling_supply_temperature/>
<heat_output_curve/>
<heat_fuel_consumption_curve/>
<heat_efficiency_curve/>
<cooling_output_curve/>
<cooling_fuel_consumption_curve/>
<cooling_efficiency_curve/>
<distribution_systems/>
<energy_storage_systems/>
<domestic_hot_water>True</domestic_hot_water>
<heat_supply_temperature/>
<cooling_supply_temperature/>
<simultaneous_heat_cold/>
</non_pv_generation_component>
<pv_generation_component>
<system_id>7</system_id>
<name>template Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name/>
<manufacturer/>
<nominal_electricity_output/>
<electricity_efficiency>0.2</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>45</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>500</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.3</cell_temperature_coefficient>
<width>2.0</width>
<height>1.0</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>8</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>RE400CAA Pure 2</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>305</nominal_electricity_output>
<electricity_efficiency>0.206</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>400</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>1.86</width>
<height>1.04</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>9</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>RE410CAA Pure 2</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>312</nominal_electricity_output>
<electricity_efficiency>0.211</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>410</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>1.86</width>
<height>1.04</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>10</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>RE420CAA Pure 2</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>320</nominal_electricity_output>
<electricity_efficiency>0.217</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>420</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>1.86</width>
<height>1.04</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>11</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>RE430CAA Pure 2</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>327</nominal_electricity_output>
<electricity_efficiency>0.222</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>430</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>1.86</width>
<height>1.04</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>12</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>REC600AA Pro M</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>457</nominal_electricity_output>
<electricity_efficiency>0.211</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>600</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>2.17</width>
<height>1.3</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>13</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>REC610AA Pro M</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>464</nominal_electricity_output>
<electricity_efficiency>0.215</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>610</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>2.17</width>
<height>1.3</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>14</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>REC620AA Pro M</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>472</nominal_electricity_output>
<electricity_efficiency>0.218</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>620</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>2.17</width>
<height>1.3</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>15</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>REC630AA Pro M</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>480</nominal_electricity_output>
<electricity_efficiency>0.222</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>630</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>2.17</width>
<height>1.3</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
<pv_generation_component>
<system_id>16</system_id>
<name>Photovoltaic Module</name>
<system_type>photovoltaic</system_type>
<model_name>REC640AA Pro M</model_name>
<manufacturer>REC</manufacturer>
<nominal_electricity_output>487</nominal_electricity_output>
<electricity_efficiency>0.215</electricity_efficiency>
<nominal_ambient_temperature>20</nominal_ambient_temperature>
<nominal_cell_temperature>44</nominal_cell_temperature>
<nominal_radiation>800</nominal_radiation>
<standard_test_condition_cell_temperature>25</standard_test_condition_cell_temperature>
<standard_test_condition_radiation>1000</standard_test_condition_radiation>
<standard_test_condition_maximum_power>640</standard_test_condition_maximum_power>
<cell_temperature_coefficient>0.24</cell_temperature_coefficient>
<width>2.17</width>
<height>1.3</height>
<distribution_systems/>
<energy_storage_systems/>
<simultaneous_heat_cold>False</simultaneous_heat_cold>
</pv_generation_component>
</energy_generation_components>
<energy_storage_components>
<thermalStorages>
<storage_id>6</storage_id>
<name>template Hot Water Storage Tank</name>
<type_energy_stored>thermal</type_energy_stored>
<model_name/>
<manufacturer/>
<maximum_operating_temperature>95.0</maximum_operating_temperature>
<insulation>
<material_id>1</material_id>
<insulationThickness>90.0</insulationThickness>
</insulation>
<physical_characteristics>
<material_id>2</material_id>
<tankThickness>0</tankThickness>
<height>1.5</height>
<tankMaterial>Steel</tankMaterial>
<volume/>
</physical_characteristics>
<storage_medium>
<medium_id>1</medium_id>
</storage_medium>
<storage_type>sensible</storage_type>
<nominal_capacity/>
<losses_ratio/>
<heating_coil_capacity/>
</thermalStorages>
<thermalStorages>
<storage_id>7</storage_id>
<name>template Hot Water Storage Tank with Heating Coil</name>
<type_energy_stored>thermal</type_energy_stored>
<model_name/>
<manufacturer/>
<maximum_operating_temperature>95.0</maximum_operating_temperature>
<insulation>
<material_id>1</material_id>
<insulationThickness>90.0</insulationThickness>
</insulation>
<physical_characteristics>
<material_id>2</material_id>
<tankThickness>0</tankThickness>
<height>1.5</height>
<tankMaterial>Steel</tankMaterial>
<volume/>
</physical_characteristics>
<storage_medium>
<medium_id>1</medium_id>
</storage_medium>
<storage_type>sensible</storage_type>
<nominal_capacity/>
<losses_ratio/>
<heating_coil_capacity>5000</heating_coil_capacity>
</thermalStorages>
</energy_storage_components>
<materials>
<material>
<material_id>1</material_id>
<name>Polyurethane</name>
<solar_absorptance/>
<thermal_absorptance/>
<visible_absorptance/>
<no_mass/>
<thermal_resistance/>
<density/>
<specific_heat/>
<conductivity>0.028</conductivity>
</material>
<material>
<material_id>2</material_id>
<name>Steel</name>
<solar_absorptance/>
<thermal_absorptance/>
<visible_absorptance/>
<no_mass/>
<thermal_resistance/>
<density/>
<specific_heat/>
<conductivity>18</conductivity>
</material>
</materials>
<distribution_systems>
<distribution_system/>
</distribution_systems>
<dissipation_systems>
<dissipation_system/>
</dissipation_systems>
<systems>
<system>
<id>1</id>
<name>Central gas system</name>
<schema/>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>1</generation_id>
</components>
</system>
<system>
<id>2</id>
<name>Central Joule system</name>
<schema/>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>2</generation_id>
</components>
</system>
<system>
<id>3</id>
<name>Central butane system</name>
<schema/>
<demands>
<demand>heating</demand>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>4</generation_id>
</components>
</system>
<system>
<id>4</id>
<name>Single zone split system</name>
<schema/>
<demands>
<demand>cooling</demand>
</demands>
<components>
<generation_id>5</generation_id>
</components>
</system>
<system>
<id>5</id>
<name>4 pipe heat pump system</name>
<schema/>
<demands>
<demand>heating</demand>
<demand>cooling</demand>
</demands>
<components>
<generation_id>3</generation_id>
</components>
</system>
<system>
<id>6</id>
<name>PV</name>
<schema/>
<demands>
<demand>electricity</demand>
</demands>
<components>
<generation_id>7</generation_id>
</components>
</system>
<system>
<id>7</id>
<name>Gas heating</name>
<schema/>
<demands>
<demand>heating</demand>
</demands>
<components>
<generation_id>1</generation_id>
</components>
</system>
<system>
<id>8</id>
<name>Electrical heating</name>
<schema/>
<demands>
<demand>heating</demand>
</demands>
<components>
<generation_id>2</generation_id>
</components>
</system>
<system>
<id>9</id>
<name>Butane heating</name>
<schema/>
<demands>
<demand>heating</demand>
</demands>
<components>
<generation_id>4</generation_id>
</components>
</system>
<system>
<id>10</id>
<name>Gas hot water system</name>
<schema/>
<demands>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>1</generation_id>
</components>
</system>
<system>
<id>11</id>
<name>Electrical hot water system</name>
<schema/>
<demands>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>2</generation_id>
</components>
</system>
<system>
<id>12</id>
<name>Butane hot water system</name>
<schema/>
<demands>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>4</generation_id>
</components>
</system>
<system>
<id>13</id>
<name>Heat Pump hot water system</name>
<schema/>
<demands>
<demand>domestic_hot_water</demand>
</demands>
<components>
<generation_id>6</generation_id>
</components>
</system>
</systems>
<system_archetypes>
<system_archetype id="1">
<name>Gas boiler for heating and hot water heater with split cooling</name>
<systems>
<system_id>1</system_id>
<system_id>4</system_id>
</systems>
</system_archetype>
<system_archetype id="2">
<name>Joule heater for heating and hot water heater with split cooling</name>
<systems>
<system_id>2</system_id>
<system_id>4</system_id>
</systems>
</system_archetype>
<system_archetype id="3">
<name>Butane heater for heating and hot water heater with split cooling</name>
<systems>
<system_id>3</system_id>
<system_id>4</system_id>
</systems>
</system_archetype>
<system_archetype id="4">
<name>Gas heating</name>
<systems>
<system_id>1</system_id>
</systems>
</system_archetype>
<system_archetype id="5">
<name>Electrical joule heating</name>
<systems>
<system_id>2</system_id>
</systems>
</system_archetype>
<system_archetype id="6">
<name>Butane heating</name>
<systems>
<system_id>3</system_id>
</systems>
</system_archetype>
<system_archetype id="7">
<name>Heat pump with gas water heater</name>
<systems>
<system_id>5</system_id>
<system_id>7</system_id>
</systems>
</system_archetype>
<system_archetype id="8">
<name>Heat pump with joule water heater</name>
<systems>
<system_id>5</system_id>
<system_id>8</system_id>
</systems>
</system_archetype>
<system_archetype id="9">
<name>Heat pump with butane water heater</name>
<systems>
<system_id>5</system_id>
<system_id>9</system_id>
</systems>
</system_archetype>
<system_archetype id="10">
<name>Heat pump with gas water heater and rooftop PV</name>
<systems>
<system_id>5</system_id>
<system_id>7</system_id>
<system_id>6</system_id>
</systems>
</system_archetype>
<system_archetype id="11">
<name>Heat pump with joule water heater and rooftop PV</name>
<systems>
<system_id>5</system_id>
<system_id>8</system_id>
<system_id>6</system_id>
</systems>
</system_archetype>
<system_archetype id="12">
<name>Rooftop PV</name>
<systems>
<system_id>6</system_id>
</systems>
</system_archetype>
<system_archetype id="13">
<name>Joule heater with split cooling and gas hot water</name>
<systems>
<system_id>4</system_id>
<system_id>8</system_id>
<system_id>10</system_id>
</systems>
</system_archetype>
<system_archetype id="14">
<name>Joule heater with split cooling and butane hot water</name>
<systems>
<system_id>4</system_id>
<system_id>8</system_id>
<system_id>12</system_id>
</systems>
</system_archetype>
<system_archetype id="15">
<name>PV and heat pump</name>
<systems>
<system_id>5</system_id>
<system_id>6</system_id>
<system_id>13</system_id>
</systems>
</system_archetype>
</system_archetypes>
</EnergySystemCatalog>

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 64 KiB

View File

@ -1,6 +0,0 @@
<?xml version="1.0" encoding="UTF-8" ?>
<nrcan base_url="https://raw.githubusercontent.com/NREL/openstudio-standards/master/lib/openstudio-standards/standards/necb/">
<space_types>NECB2015/data/space_types.json</space_types>
<space_types_compliance>NECB2015/qaqc/qaqc_data/space_compliance_2015.json</space_types_compliance>>
<schedules>NECB2015/data/schedules.json</schedules>
</nrcan>

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,904 @@
{
"tables": {
"schedules": {
"data_type": "table",
"refs": [
"DBHE CTE Tabla b-Anejo D"
],
"table": [
{
"name": "DBHE-CTE-Occupancy-sensible",
"category": "Occupancy",
"units": "FRACTION",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1,
1,
1,
1,
1,
1,
0.25,
0.25,
0.25,
0.25,
0.25,
0.25,
0.25,
0.25,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
1
]
},
{
"name": "DBHE-CTE-Occupancy-sensible",
"category": "Occupancy",
"units": "FRACTION",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1
]
},
{
"name": "DBHE-CTE-Occupancy-sensible",
"category": "Occupancy",
"units": "FRACTION",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1
]
},
{
"name": "DBHE-CTE-Occupancy-latent",
"category": "Occupancy",
"units": "FRACTION",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1,
1,
1,
1,
1,
1,
0.25,
0.25,
0.25,
0.25,
0.25,
0.25,
0.25,
0.25,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
0.5,
1
]
},
{
"name": "DBHE-CTE-Occupancy-latent",
"category": "Occupancy",
"units": "FRACTION",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1
]
},
{
"name": "DBHE-CTE-Occupancy-latent",
"category": "Occupancy",
"units": "FRACTION",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1,
1
]
},
{
"name": "DBHE-CTE-Lighting",
"category": "Lighting",
"units": "FRACTION",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.1,
0.1,
0.1,
0.1,
0.1,
0.1,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.5,
1,
1,
1,
1,
1,
0.5
]
},
{
"name": "DBHE-CTE-Lighting",
"category": "Lighting",
"units": "FRACTION",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.1,
0.1,
0.1,
0.1,
0.1,
0.1,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.5,
1,
1,
1,
1,
1,
0.5
]
},
{
"name": "DBHE-CTE-Lighting",
"category": "Lighting",
"units": "FRACTION",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.1,
0.1,
0.1,
0.1,
0.1,
0.1,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.5,
1,
1,
1,
1,
1,
0.5
]
},
{
"name": "DBHE-CTE-Equipment",
"category": "Equipment",
"units": "FRACTION",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.1,
0.1,
0.1,
0.1,
0.1,
0.1,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.5,
1,
1,
1,
1,
1,
0.5
]
},
{
"name": "DBHE-CTE-Equipment",
"category": "Equipment",
"units": "FRACTION",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.1,
0.1,
0.1,
0.1,
0.1,
0.1,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.5,
1,
1,
1,
1,
1,
0.5
]
},
{
"name": "DBHE-CTE-Equipment",
"category": "Equipment",
"units": "FRACTION",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.1,
0.1,
0.1,
0.1,
0.1,
0.1,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.33,
0.5,
1,
1,
1,
1,
1,
0.5
]
},
{
"name": "DBHE-CTE-Thermostat Setpoint-Heating",
"category": "Thermostat Setpoint",
"units": "TEMPERATURE",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
17.0,
17.0,
17.0,
17.0,
17.0,
17.0,
17.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
21.0,
20.0,
17.0,
17.0
]
},
{
"name": "DBHE-CTE-Thermostat Setpoint-Heating",
"category": "Thermostat Setpoint",
"units": "TEMPERATURE",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
22.0,
18.0,
18.0,
18.0,
18.0,
18.0,
18.0,
20.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0
]
},
{
"name": "DBHE-CTE-Thermostat Setpoint-Heating",
"category": "Thermostat Setpoint",
"units": "TEMPERATURE",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
22.0,
18.0,
18.0,
18.0,
18.0,
18.0,
18.0,
20.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0,
22.0
]
},
{
"name": "DBHE-CTE-Thermostat Setpoint-Cooling",
"category": "Thermostat Setpoint",
"units": "TEMPERATURE",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
28.0,
28.0,
28.0,
28.0,
28.0,
28.0,
28.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
28.0,
28.0
]
},
{
"name": "DBHE-CTE-Thermostat Setpoint-Cooling",
"category": "Thermostat Setpoint",
"units": "TEMPERATURE",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
28.0,
28.0,
28.0,
28.0,
28.0,
28.0,
28.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
28.0,
28.0
]
},
{
"name": "DBHE-CTE-Thermostat Setpoint-Cooling",
"category": "Thermostat Setpoint",
"units": "TEMPERATURE",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
28.0,
28.0,
28.0,
28.0,
28.0,
28.0,
28.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
25.0,
28.0,
28.0
]
},
{
"name": "Always On",
"category": "Unknown",
"units": null,
"day_types": "Default",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Constant",
"notes": null,
"values": [
1.0
]
},
{
"name": "default_HVAC_schedule",
"category": "Fan",
"units": "ON_OFF",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0
]
},
{
"name": "default_HVAC_schedule",
"category": "Fan",
"units": "ON_OFF",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0
]
},
{
"name": "default_HVAC_schedule",
"category": "Fan",
"units": "ON_OFF",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0,
1.0
]
},
{
"name": "DBHE-CTE-Service Water Heating",
"category": "Service Water Heating",
"units": "FRACTION",
"day_types": "Default|Wkdy",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.01,
0.00,
0.00,
0.00,
0.00,
0.01,
0.03,
0.1,
0.07,
0.07,
0.06,
0.06,
0.05,
0.05,
0.04,
0.03,
0.04,
0.04,
0.05,
0.07,
0.06,
0.06,
0.05,
0.05
]
},
{
"name": "DBHE-CTE-Service Water Heating",
"category": "Service Water Heating",
"units": "FRACTION",
"day_types": "Sat",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.01,
0.00,
0.00,
0.00,
0.00,
0.01,
0.03,
0.1,
0.07,
0.07,
0.06,
0.06,
0.05,
0.05,
0.04,
0.03,
0.04,
0.04,
0.05,
0.07,
0.06,
0.06,
0.05,
0.05
]
},
{
"name": "DBHE-CTE-Service Water Heating",
"category": "Service Water Heating",
"units": "FRACTION",
"day_types": "Sun|Hol",
"start_date": "2014-01-01T00:00:00+00:00",
"end_date": "2014-12-31T00:00:00+00:00",
"type": "Hourly",
"notes": null,
"values": [
0.01,
0.00,
0.00,
0.00,
0.00,
0.01,
0.03,
0.1,
0.07,
0.07,
0.06,
0.06,
0.05,
0.05,
0.04,
0.03,
0.04,
0.04,
0.05,
0.07,
0.06,
0.06,
0.05,
0.05
]
}
]
}}}

View File

@ -0,0 +1,30 @@
{
"tables": {
"space_compliance": {
"data_type": "table",
"refs": {
"lighting_per_area_w_per_m2": "DBHE-CTE Tabla b-Anejo D",
"occupancy_per_area_people_per_m2": "DBHE CTE Tabla b-Anejo D",
"occupancy_schedule": "DBHE-CTE Tabla b-Anejo D",
"electric_equipment_per_area_w_per_m2": "DBHE CTE Tabla b-Anejo D"
},
"tolerance": {
"lighting_per_area_w_per_m2": 1,
"occupancy_per_area_people_per_m2": 3,
"occupancy_schedule": null,
"electric_equipment_per_area_w_per_m2": 1
},
"table": [
{
"template": "DBHE-CTE",
"building_type": "residential",
"space_type": "WholeBuilding",
"lighting_per_area_w_per_m2": 4.4,
"occupancy_per_area_people_per_m2": 0.014333333,
"occupancy_schedule": "DBHE-CTE-Occupancy",
"electric_equipment_per_area_w_per_m2": 4.4,
"service_water_heating_peak_flow_per_area": 0.02272990107962068
}]
}
}
}

View File

@ -0,0 +1,97 @@
{
"tables": {
"space_types": {
"data_type": "table",
"refs": [
"assumption"
],
"table": [
{
"building_type": "residential",
"space_type": "WholeBuilding",
"rgb": "255_255_255",
"lighting_standard": "DBHE-CTE",
"lighting_primary_space_type": "residential",
"lighting_secondary_space_type": "WholeBuilding",
"lighting_per_area": 4.4,
"lighting_per_person": null,
"additional_lighting_per_area": null,
"rel_absence_occ": 0.0,
"personal_control": 0.0,
"occ_sense": 0.0,
"lighting_fraction_to_return_air": 0.0,
"lighting_fraction_radiant": 0.5,
"lighting_fraction_visible": 0.2,
"lighting_fraction_replaceable": null,
"lpd_fractionlinear_fluorescent": 1.0,
"lpd_fractioncompact_fluorescent": null,
"lpd_fractionhigh_bay": null,
"lpd_fractionspecialty_lighting": null,
"lpd_fractionexit_lighting": null,
"lighting_schedule": "DBHE-CTE-Lighting",
"compact_fluorescent_lighting_schedule": null,
"high_bay_lighting_schedule": null,
"specialty_lighting_schedule": null,
"exit_lighting_schedule": null,
"target_illuminance_setpoint": 125,
"target_illuminance_setpoint_ref": null,
"psa_nongeometry_fraction": null,
"ssa_nongeometry_fraction": null,
"ventilation_standard": null,
"ventilation_primary_space_type": "residential",
"ventilation_secondary_space_type": "WholeBuilding",
"ventilation_per_area": 0,
"ventilation_per_person": 0,
"ventilation_air_changes": 0.4,
"minimum_total_air_changes": null,
"occupancy_per_area": 2.15,
"occupancy_schedule": "DBHE-CTE-Occupancy-sensible",
"occupancy_activity_schedule": null,
"infiltration_per_exterior_area": 0.4,
"infiltration_per_exterior_wall_area": null,
"infiltration_air_changes": null,
"infiltration_schedule": "Always On",
"infiltration_schedule_perimeter": null,
"gas_equipment_per_area": null,
"gas_equipment_fraction_latent": null,
"gas_equipment_fraction_radiant": null,
"gas_equipment_fraction_lost": null,
"gas_equipment_schedule": null,
"electric_equipment_per_area": 4.4,
"electric_equipment_fraction_latent": 0.0,
"electric_equipment_fraction_radiant": 0.5,
"electric_equipment_fraction_lost": 0.0,
"electric_equipment_schedule": "DBHE-CTE-Equipment",
"additional_electric_equipment_schedule": null,
"additional_gas_equipment_schedule": null,
"heating_setpoint_schedule": "DBHE-CTE-Thermostat Setpoint-Heating",
"cooling_setpoint_schedule": "DBHE-CTE-Thermostat Setpoint-Cooling",
"service_water_heating_peak_flow_rate": null,
"service_water_heating_area": null,
"service_water_heating_peak_flow_per_area": 0.009385225,
"service_water_heating_target_temperature": 60.0,
"service_water_heating_fraction_sensible": null,
"service_water_heating_fraction_latent": null,
"service_water_heating_schedule": "DBHE-CTE-Service Water Heating",
"exhaust_per_area": null,
"exhaust_fan_efficiency": null,
"exhaust_fan_power": null,
"exhaust_fan_pressure_rise": null,
"exhaust_fan_maximum_flow_rate": null,
"exhaust_schedule": null,
"balanced_exhaust_fraction_schedule": null,
"is_residential": null,
"necb_hvac_system_selection_type": "residential",
"necb_schedule_type": "G",
"notes": null,
"ventilation_occupancy_rate_people_per_1000ft2": 10,
"ventilation_occupancy_standard": null,
"ventilation_standard_space_type": null,
"sensible_convective_internal_gain": 0.86,
"sensible_radiative_internal_gain": 1.29,
"latent_internal_gain": 1.36
}
]
}
}
}

View File

@ -0,0 +1,248 @@
"""
Cerc Idf exports one city or some buildings to idf format
SPDX - License - Identifier: LGPL - 3.0 - or -later
Copyright © 2022 Concordia CERC group
Project Coder Guille Guillermo.GutierrezMorote@concordia.ca
Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concordia.ca
Oriol Gavalda Torrellas oriol.gavalda@concordia.ca
"""
import copy
import os
import shutil
import subprocess
import hub.exports.building_energy.idf_helper as idf_cte
import hub.helpers.constants as cte
from hub.city_model_structure.attributes.schedule import Schedule
from hub.exports.building_energy.idf_helper.idf_appliance import IdfAppliance
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
from hub.exports.building_energy.idf_helper.idf_construction import IdfConstruction
from hub.exports.building_energy.idf_helper.idf_dhw import IdfDhw
from hub.exports.building_energy.idf_helper.idf_file_schedule import IdfFileSchedule
from hub.exports.building_energy.idf_helper.idf_heating_system import IdfHeatingSystem
from hub.exports.building_energy.idf_helper.idf_infiltration import IdfInfiltration
from hub.exports.building_energy.idf_helper.idf_lighting import IdfLighting
from hub.exports.building_energy.idf_helper.idf_material import IdfMaterial
from hub.exports.building_energy.idf_helper.idf_occupancy import IdfOccupancy
from hub.exports.building_energy.idf_helper.idf_schedule import IdfSchedule
from hub.exports.building_energy.idf_helper.idf_shading import IdfShading
from hub.exports.building_energy.idf_helper.idf_surfaces import IdfSurfaces
from hub.exports.building_energy.idf_helper.idf_thermostat import IdfThermostat
from hub.exports.building_energy.idf_helper.idf_ventilation import IdfVentilation
from hub.exports.building_energy.idf_helper.idf_window import IdfWindow
from hub.exports.building_energy.idf_helper.idf_windows_constructions import IdfWindowsConstructions
from hub.exports.building_energy.idf_helper.idf_windows_material import IdfWindowsMaterial
from hub.exports.building_energy.idf_helper.idf_zone import IdfZone
class CercIdf(IdfBase):
"""
Exports city to IDF
"""
_schedules_added_to_idf = {}
_materials_added_to_idf = {}
_windows_added_to_idf = {}
_constructions_added_to_idf = {}
_thermostat_added_to_idf = {}
def __init__(self, city, output_path, idf_file_path, idd_file_path, epw_file_path, target_buildings=None):
super().__init__(city, output_path, idf_file_path, idd_file_path, epw_file_path, target_buildings)
self._add_surfaces = IdfSurfaces.add
self._add_file_schedule = IdfFileSchedule.add
self._add_idf_schedule = IdfSchedule.add
self._add_construction = IdfConstruction.add
self._add_material = IdfMaterial.add
self._add_windows_material = IdfWindowsMaterial.add
self._add_windows_constructions = IdfWindowsConstructions.add
self._add_occupancy = IdfOccupancy.add
self._add_lighting = IdfLighting.add
self._add_appliance = IdfAppliance.add
self._add_infiltration = IdfInfiltration.add
self._add_infiltration_surface = IdfInfiltration.add_surface
self._add_ventilation = IdfVentilation.add
self._add_zone = IdfZone.add
self._add_thermostat = IdfThermostat.add
self._add_heating_system = IdfHeatingSystem.add
self._add_dhw = IdfDhw.add
self._add_shading = IdfShading.add
self._add_windows = IdfWindow.add
with open(self._idf_file_path, 'r', encoding='UTF-8') as base_idf:
lines = base_idf.readlines()
# Change city name
comment = f' !- Name'
field = f' Buildings in {self._city.name},'.ljust(26, ' ')
lines[15] = f'{field}{comment}\n'
with open(self._output_file_path, 'w', encoding='UTF-8') as self._idf_file:
self._idf_file.writelines(lines)
self._export()
def _create_geometry_rules(self):
file = self._files['constructions']
self._write_to_idf_format(file, idf_cte.GLOBAL_GEOMETRY_RULES)
self._write_to_idf_format(file, 'UpperLeftCorner', 'Starting Vertex Position')
self._write_to_idf_format(file, 'CounterClockWise', 'Vertex Entry Direction')
self._write_to_idf_format(file, 'World', 'Coordinate System', ';')
def _merge_files(self):
for file in self._files.values():
file.close()
for path in self._file_paths.values():
with open(path, 'r', encoding='UTF-8') as file:
lines = file.readlines()
self._idf_file.writelines(lines)
for path in self._file_paths.values():
os.unlink(path)
def _add_outputs(self):
with open(self._outputs_file_path, 'r', encoding='UTF-8') as base_idf:
lines = base_idf.readlines()
self._idf_file.writelines(lines)
@staticmethod
def _create_infiltration_schedules(thermal_zone):
_infiltration_schedules = []
if thermal_zone.thermal_control is None:
return []
for hvac_availability_schedule in thermal_zone.thermal_control.hvac_availability_schedules:
_schedule = Schedule()
_schedule.type = cte.INFILTRATION
_schedule.data_type = cte.FRACTION
_schedule.time_step = cte.HOUR
_schedule.time_range = cte.DAY
_schedule.day_types = copy.deepcopy(hvac_availability_schedule.day_types)
_infiltration_values = []
for hvac_value in hvac_availability_schedule.values:
if hvac_value == 0:
_infiltration_values.append(1.0)
else:
if thermal_zone.infiltration_rate_system_off == 0:
_infiltration_values.append(0.0)
else:
_infiltration_values.append(
thermal_zone.infiltration_rate_system_on / thermal_zone.infiltration_rate_system_off)
_schedule.values = _infiltration_values
_infiltration_schedules.append(_schedule)
return _infiltration_schedules
@staticmethod
def _create_ventilation_schedules(thermal_zone):
_ventilation_schedules = []
if thermal_zone.thermal_control is None:
return []
for hvac_availability_schedule in thermal_zone.thermal_control.hvac_availability_schedules:
_schedule = Schedule()
_schedule.type = cte.VENTILATION
_schedule.data_type = cte.FRACTION
_schedule.time_step = cte.HOUR
_schedule.time_range = cte.DAY
_schedule.day_types = copy.deepcopy(hvac_availability_schedule.day_types)
_ventilation_schedules = thermal_zone.thermal_control.hvac_availability_schedules
return _ventilation_schedules
@staticmethod
def _create_constant_value_schedules(value, amount):
_schedule = Schedule()
_schedule.type = ''
_schedule.data_type = cte.ANY_NUMBER
_schedule.time_step = cte.HOUR
_schedule.time_range = cte.DAY
_schedule.day_types = ['monday',
'tuesday',
'wednesday',
'thursday',
'friday',
'saturday',
'sunday',
'holiday',
'winter_design_day',
'summer_design_day']
_schedule.values = [value for _ in range(0, amount)]
return [_schedule]
def _export(self):
for building in self._city.buildings:
is_target = building.name in self._target_buildings or building.name in self._adjacent_buildings
for internal_zone in building.internal_zones:
if internal_zone.thermal_zones_from_internal_zones is None:
is_target = False
continue
for thermal_zone in internal_zone.thermal_zones_from_internal_zones:
if is_target:
service_temperature = thermal_zone.domestic_hot_water.service_temperature
usage = thermal_zone.usage_name
occ = thermal_zone.occupancy
if occ.occupancy_density == 0:
total_heat = 0
else:
total_heat = (
occ.sensible_convective_internal_gain +
occ.sensible_radiative_internal_gain +
occ.latent_internal_gain
) / occ.occupancy_density
self._add_idf_schedule(self, usage, 'Infiltration', self._create_infiltration_schedules(thermal_zone))
self._add_idf_schedule(self, usage, 'Ventilation', self._create_ventilation_schedules(thermal_zone))
self._add_idf_schedule(self, usage, 'Occupancy', thermal_zone.occupancy.occupancy_schedules)
self._add_idf_schedule(self, usage, 'HVAC AVAIL', thermal_zone.thermal_control.hvac_availability_schedules)
self._add_idf_schedule(self, usage, 'Heating thermostat',
thermal_zone.thermal_control.heating_set_point_schedules)
self._add_idf_schedule(self, usage, 'Cooling thermostat',
thermal_zone.thermal_control.cooling_set_point_schedules)
self._add_idf_schedule(self, usage, 'Lighting', thermal_zone.lighting.schedules)
self._add_idf_schedule(self, usage, 'Appliance', thermal_zone.appliances.schedules)
self._add_idf_schedule(self, usage, 'DHW_prof', thermal_zone.domestic_hot_water.schedules)
self._add_idf_schedule(self, usage, 'DHW_temp',
self._create_constant_value_schedules(service_temperature, 24))
self._add_idf_schedule(self, usage, 'Activity Level', self._create_constant_value_schedules(total_heat, 24))
self._add_file_schedule(self, usage, 'cold_temp',
self._create_constant_value_schedules(building.cold_water_temperature[cte.HOUR],
24))
for thermal_boundary in thermal_zone.thermal_boundaries:
self._add_material(self, thermal_boundary)
self._add_construction(self, thermal_boundary)
for thermal_opening in thermal_boundary.thermal_openings:
self._add_windows_material(self, thermal_boundary, thermal_opening)
self._add_windows_constructions(self, thermal_boundary)
self._add_zone(self, thermal_zone, building.name)
self._add_occupancy(self, thermal_zone, building.name)
self._add_lighting(self, thermal_zone, building.name)
self._add_appliance(self, thermal_zone, building.name)
if self._calculate_with_new_infiltration: # ToDo: Check with oriol if we want to keep the old method too
self._add_infiltration_surface(self, thermal_zone, building.name)
else:
self._add_infiltration(self, thermal_zone, building.name)
self._add_ventilation(self, thermal_zone, building.name)
self._add_thermostat(self, thermal_zone)
self._add_heating_system(self, thermal_zone, building.name)
self._add_dhw(self, thermal_zone, building.name)
if is_target:
self._add_surfaces(self, building, building.name)
self._add_windows(self, building)
else:
self._add_shading(self, building)
self._create_output_control_lighting() # Add lighting control to the lighting
# Create base values
self._create_geometry_rules()
# Merge files
self._merge_files()
self._add_outputs()
@property
def _energy_plus(self):
return shutil.which('energyplus')
def run(self):
cmd = [self._energy_plus,
'--weather', self._epw_file_path,
'--output-directory', self._output_path,
'--idd', self._idd_file_path,
'--expandobjects',
'--readvars',
'--output-prefix', f'{self._city.name}_',
self._output_file_path]
subprocess.run(cmd, cwd=self._output_path)

View File

@ -169,7 +169,7 @@ class EnergyAde:
def _building_geometry(self, building, building_dic, city):
building_dic['bldg:Building']['bldg:function'] = building.function
building_dic['bldg:Building']['bldg:usage'] = building.usages_percentage
building_dic['bldg:Building']['bldg:usage'] = building.usages
building_dic['bldg:Building']['bldg:yearOfConstruction'] = building.year_of_construction
building_dic['bldg:Building']['bldg:roofType'] = building.roof_type
building_dic['bldg:Building']['bldg:measuredHeight'] = {

View File

@ -7,8 +7,13 @@ Code contributors: Pilar Monsalvete Alvarez de Uribarri pilar.monsalvete@concord
Oriol Gavalda Torrellas oriol.gavalda@concordia.ca
"""
import copy
import datetime
import shutil
import subprocess
from pathlib import Path
from geomeppy import IDF
import hub.helpers.constants as cte
from hub.city_model_structure.attributes.schedule import Schedule
from hub.city_model_structure.building_demand.thermal_zone import ThermalZone
@ -104,6 +109,7 @@ class Idf:
else:
for building_name in target_buildings:
building = city.city_object(building_name)
print('Name: ', building_name)
if building.neighbours is not None:
self._adjacent_buildings += building.neighbours
self._export()
@ -275,12 +281,13 @@ class Idf:
_kwargs[f'Field_{counter + 2}'] = 'Until: 24:00,0.0'
self._idf.newidfobject(self._COMPACT_SCHEDULE, **_kwargs)
def _write_schedules_file(self, usage, schedule):
file_name = str((Path(self._output_path) / f'{schedule.type} schedules {usage}.dat').resolve())
with open(file_name, 'w', encoding='utf8') as file:
for value in schedule.values:
file.write(f'{str(value)},\n')
return file_name
def _write_schedules_file(self, schedule, usage):
file_name = str((Path(self._output_path) / f'{schedule.type} schedules {usage.replace("/","_")}.csv').resolve())
if not Path(file_name).exists():
with open(file_name, 'w', encoding='utf8') as file:
for value in schedule.values:
file.write(f'{str(value)},\n')
return Path(file_name).name
def _add_file_schedule(self, usage, schedule, file_name):
_schedule = self._idf.newidfobject(self._FILE_SCHEDULE, Name=f'{schedule.type} schedules {usage}')
@ -304,7 +311,7 @@ class Idf:
for schedule in self._idf.idfobjects[self._FILE_SCHEDULE]:
if schedule.Name == f'{schedule_type} schedules {usage}':
return
file_name = self._write_schedules_file(usage, new_schedules[0])
file_name = self._write_schedules_file(new_schedules[0], usage)
self._add_file_schedule(usage, new_schedules[0], file_name)
return
@ -321,12 +328,13 @@ class Idf:
if construction.Name == vegetation_name:
return
else:
if construction.Name == thermal_boundary.construction_name:
if construction.Name == f'{thermal_boundary.construction_name} {thermal_boundary.parent_surface.type}':
return
if thermal_boundary.layers is None:
for material in self._idf.idfobjects[self._MATERIAL]:
if material.Name == "DefaultMaterial":
return
self._idf.set_default_constructions()
return
for layer in thermal_boundary.layers:
@ -340,7 +348,8 @@ class Idf:
for i in range(0, len(layers) - 1):
_kwargs[f'Layer_{i + 2}'] = layers[i].material_name
else:
_kwargs = {'Name': thermal_boundary.construction_name, 'Outside_Layer': layers[0].material_name}
_kwargs = {'Name': f'{thermal_boundary.construction_name} {thermal_boundary.parent_surface.type}',
'Outside_Layer': layers[0].material_name}
for i in range(1, len(layers) - 1):
_kwargs[f'Layer_{i + 1}'] = layers[i].material_name
self._idf.newidfobject(self._CONSTRUCTION, **_kwargs)
@ -387,9 +396,9 @@ class Idf:
thermostat = self._add_thermostat(thermal_zone)
self._idf.newidfobject(self._IDEAL_LOAD_AIR_SYSTEM,
Zone_Name=zone_name,
System_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
Heating_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
Cooling_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
System_Availability_Schedule_Name=f'Thermostat_availability schedules {thermal_zone.usage_name}',
Heating_Availability_Schedule_Name=f'Thermostat_availability schedules {thermal_zone.usage_name}',
Cooling_Availability_Schedule_Name=f'Thermostat_availability schedules {thermal_zone.usage_name}',
Template_Thermostat_Name=thermostat.Name)
def _add_occupancy(self, thermal_zone, zone_name):
@ -403,7 +412,7 @@ class Idf:
self._idf.newidfobject(self._PEOPLE,
Name=f'{zone_name}_occupancy',
Zone_or_ZoneList_Name=zone_name,
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
Number_of_People_Schedule_Name=f'Occupancy schedules {thermal_zone.usage_name}',
Number_of_People_Calculation_Method="People",
Number_of_People=number_of_people,
@ -420,7 +429,7 @@ class Idf:
self._idf.newidfobject(self._LIGHTS,
Name=f'{zone_name}_lights',
Zone_or_ZoneList_Name=zone_name,
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
Schedule_Name=f'Lighting schedules {thermal_zone.usage_name}',
Design_Level_Calculation_Method=method,
Watts_per_Zone_Floor_Area=watts_per_zone_floor_area,
@ -438,8 +447,8 @@ class Idf:
subcategory = f'ELECTRIC EQUIPMENT#{zone_name}#InteriorEquipment'
self._idf.newidfobject(self._APPLIANCES,
Fuel_Type=fuel_type,
Name=f'{zone_name}_appliance',
Zone_or_ZoneList_Name=zone_name,
Name=zone_name,
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
Schedule_Name=f'Appliance schedules {thermal_zone.usage_name}',
Design_Level_Calculation_Method=method,
Power_per_Zone_Floor_Area=watts_per_zone_floor_area,
@ -449,28 +458,39 @@ class Idf:
)
def _add_infiltration(self, thermal_zone, zone_name):
schedule = f'Infiltration schedules {thermal_zone.usage_name}'
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
_infiltration = thermal_zone.infiltration_rate_system_off * cte.HOUR_TO_SECONDS
self._idf.newidfobject(self._INFILTRATION,
Name=f'{zone_name}_infiltration',
Zone_or_ZoneList_Name=zone_name,
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
Schedule_Name=schedule,
Design_Flow_Rate_Calculation_Method='AirChanges/Hour',
Air_Changes_per_Hour=_infiltration
)
def _add_infiltration_surface(self, thermal_zone, zone_name):
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
_infiltration = thermal_zone.infiltration_rate_area_system_off* cte.INFILTRATION_75PA_TO_4PA
self._idf.newidfobject(self._INFILTRATION,
Name=f'{zone_name}_infiltration',
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
Schedule_Name=schedule,
Design_Flow_Rate_Calculation_Method='Flow/ExteriorWallArea',
Flow_Rate_per_Exterior_Surface_Area=_infiltration
)
def _add_ventilation(self, thermal_zone, zone_name):
schedule = f'Ventilation schedules {thermal_zone.usage_name}'
_air_change = thermal_zone.mechanical_air_change * cte.HOUR_TO_SECONDS
self._idf.newidfobject(self._VENTILATION,
Name=f'{zone_name}_ventilation',
Zone_or_ZoneList_Name=zone_name,
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
Schedule_Name=schedule,
Design_Flow_Rate_Calculation_Method='AirChanges/Hour',
Air_Changes_per_Hour=_air_change
)
def _add_dhw(self, thermal_zone, zone_name):
def _add_dhw(self, thermal_zone, zone_name, usage):
peak_flow_rate = thermal_zone.domestic_hot_water.peak_flow * thermal_zone.total_floor_area
self._idf.newidfobject(self._DHW,
Name=f'DHW {zone_name}',
@ -478,13 +498,13 @@ class Idf:
Flow_Rate_Fraction_Schedule_Name=f'DHW_prof schedules {thermal_zone.usage_name}',
Target_Temperature_Schedule_Name=f'DHW_temp schedules {thermal_zone.usage_name}',
Hot_Water_Supply_Temperature_Schedule_Name=f'DHW_temp schedules {thermal_zone.usage_name}',
Cold_Water_Supply_Temperature_Schedule_Name=f'cold_temp schedules {zone_name}',
Cold_Water_Supply_Temperature_Schedule_Name=f'cold_temp schedules {usage}',
EndUse_Subcategory=f'DHW {zone_name}',
Zone_Name=zone_name
)
def _rename_building(self, city_name):
name = str(str(city_name.encode("utf-8")))
name = str(city_name.encode("utf-8"))
for building in self._idf.idfobjects[self._BUILDING]:
building.Name = f'Buildings in {name}'
building['Solar_Distribution'] = 'FullExterior'
@ -511,20 +531,27 @@ class Idf:
self._remove_sizing_periods()
self._rename_building(self._city.name)
self._lod = self._city.level_of_detail.geometry
is_target = False
for building in self._city.buildings:
is_target = building.name in self._target_buildings or building.name in self._adjacent_buildings
for internal_zone in building.internal_zones:
if internal_zone.thermal_zones_from_internal_zones is None:
self._target_buildings.remove(building.name)
is_target = False
continue
for thermal_zone in internal_zone.thermal_zones_from_internal_zones:
for thermal_boundary in thermal_zone.thermal_boundaries:
for thermal_boundary in thermal_zone.thermal_boundaries:
self._add_construction(thermal_boundary)
if thermal_boundary.parent_surface.vegetation is not None:
self._add_vegetation_material(thermal_boundary.parent_surface.vegetation)
for thermal_opening in thermal_boundary.thermal_openings:
self._add_window_construction_and_material(thermal_opening)
usage = thermal_zone.usage_name
if building.name in self._target_buildings or building.name in self._adjacent_buildings:
if is_target:
start = datetime.datetime.now()
service_temperature = thermal_zone.domestic_hot_water.service_temperature
usage = thermal_zone.usage_name
_new_schedules = self._create_infiltration_schedules(thermal_zone)
self._add_schedules(usage, 'Infiltration', _new_schedules)
_new_schedules = self._create_ventilation_schedules(thermal_zone)
@ -536,12 +563,14 @@ class Idf:
self._add_schedules(usage, 'Lighting', thermal_zone.lighting.schedules)
self._add_schedules(usage, 'Appliance', thermal_zone.appliances.schedules)
self._add_schedules(usage, 'DHW_prof', thermal_zone.domestic_hot_water.schedules)
_new_schedules = self._create_yearly_values_schedules('cold_temp',
building.cold_water_temperature[cte.HOUR])
self._add_schedules(building.name, 'cold_temp', _new_schedules)
value = thermal_zone.domestic_hot_water.service_temperature
_new_schedules = self._create_constant_value_schedules('DHW_temp', value)
_new_schedules = self._create_yearly_values_schedules('cold_temp', building.cold_water_temperature[cte.HOUR])
self._add_schedules(usage, 'cold_temp', _new_schedules)
_new_schedules = self._create_constant_value_schedules('DHW_temp', service_temperature)
self._add_schedules(usage, 'DHW_temp', _new_schedules)
_new_schedules = self._create_constant_value_schedules('INF_CONST', 1)
self._add_schedules(usage, 'INF_CONST', _new_schedules)
_new_schedules = self._create_constant_value_schedules('Thermostat_availability', 1)
self._add_schedules(usage, 'Thermostat_availability', _new_schedules)
_occ = thermal_zone.occupancy
if _occ.occupancy_density == 0:
_total_heat = 0
@ -552,14 +581,14 @@ class Idf:
self._add_schedules(usage, 'Activity Level', _new_schedules)
self._add_zone(thermal_zone, building.name)
self._add_heating_system(thermal_zone, building.name)
self._add_infiltration(thermal_zone, building.name)
self._add_infiltration_surface(thermal_zone, building.name)
self._add_ventilation(thermal_zone, building.name)
self._add_occupancy(thermal_zone, building.name)
self._add_lighting(thermal_zone, building.name)
self._add_appliances(thermal_zone, building.name)
self._add_dhw(thermal_zone, building.name)
self._add_dhw(thermal_zone, building.name, usage)
if self._export_type == "Surfaces":
if building.name in self._target_buildings or building.name in self._adjacent_buildings:
if is_target:
if building.thermal_zones_from_internal_zones is not None:
self._add_surfaces(building, building.name)
else:
@ -587,6 +616,30 @@ class Idf:
Reporting_Frequency="Hourly",
)
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Zone Lights Electricity Rate",
Reporting_Frequency="Hourly",
)
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Other Equipment Electricity Rate",
Reporting_Frequency="Hourly",
)
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Zone Air Temperature",
Reporting_Frequency="Hourly",
)
self._idf.newidfobject(
"OUTPUT:VARIABLE",
Variable_Name="Zone Air Relative Humidity",
Reporting_Frequency="Hourly",
)
# post-process to erase windows associated to adiabatic walls
windows_list = []
for window in self._idf.idfobjects[self._WINDOW]:
@ -600,14 +653,26 @@ class Idf:
self._idf.removeidfobject(window)
self._idf.saveas(str(self._output_file))
for building in self._city.buildings:
if self._export_type == "Surfaces":
if is_target and building.thermal_zones_from_internal_zones is not None:
self._add_surfaces(building, building.name)
return self._idf
@property
def _energy_plus(self):
return shutil.which('energyplus')
def run(self):
"""
Start the energy plus simulation
"""
self._idf.run(expandobjects=False, readvars=True, output_directory=self._output_path,
output_prefix=f'{self._city.name}_')
cmd = [self._energy_plus,
'--weather', self._epw_file_path,
'--output-directory', self._output_path,
'--idd', self._idd_file_path,
'--expandobjects',
'--readvars',
'--output-prefix', f'{self._city.name}_',
self._idf_file_path]
subprocess.run(cmd, cwd=self._output_path)
def _add_block(self, building):
_points = self._matrix_to_2d_list(building.foot_print.coordinates)
@ -627,8 +692,8 @@ class Idf:
self._idf.intersect_match()
def _add_shading(self, building):
for surface in building.surfaces:
shading = self._idf.newidfobject(self._SHADING, Name=f'{surface.name}')
for i, surface in enumerate(building.surfaces):
shading = self._idf.newidfobject(self._SHADING, Name=f'{building.name}_{i}')
coordinates = self._matrix_to_list(surface.solid_polygon.coordinates,
self._city.lower_corner)
shading.setcoords(coordinates)
@ -636,17 +701,17 @@ class Idf:
if solar_reflectance is None:
solar_reflectance = ConfigurationHelper().short_wave_reflectance
self._idf.newidfobject(self._SHADING_PROPERTY,
Shading_Surface_Name=f'{surface.name}',
Shading_Surface_Name=f'{building.name}_{i}',
Diffuse_Solar_Reflectance_of_Unglazed_Part_of_Shading_Surface=solar_reflectance,
Fraction_of_Shading_Surface_That_Is_Glazed=0)
def _add_pure_geometry(self, building, zone_name):
for surface in building.surfaces:
for index, surface in enumerate(building.surfaces):
outside_boundary_condition = 'Outdoors'
sun_exposure = 'SunExposed'
wind_exposure = 'WindExposed'
idf_surface_type = self.idf_surfaces[surface.type]
_kwargs = {'Name': f'{surface.name}',
_kwargs = {'Name': f'Building_{building.name}_surface_{index}',
'Surface_Type': idf_surface_type,
'Zone_Name': zone_name}
if surface.type == cte.GROUND:
@ -655,7 +720,7 @@ class Idf:
wind_exposure = 'NoWind'
if surface.percentage_shared is not None and surface.percentage_shared > 0.5:
outside_boundary_condition = 'Surface'
outside_boundary_condition_object = surface.name
outside_boundary_condition_object = f'Building_{building.name}_surface_{index}'
sun_exposure = 'NoSun'
wind_exposure = 'NoWind'
_kwargs['Outside_Boundary_Condition_Object'] = outside_boundary_condition_object
@ -676,16 +741,19 @@ class Idf:
else:
# idf only allows setting wwr for external walls
wwr = 0
self._idf.set_wwr(wwr)
try:
self._idf.set_wwr(wwr, construction='window_construction_1')
except ValueError:
self._idf.set_wwr(0, construction='window_construction_1')
def _add_surfaces(self, building, zone_name):
for thermal_zone in building.thermal_zones_from_internal_zones:
for boundary in thermal_zone.thermal_boundaries:
for index, boundary in enumerate(thermal_zone.thermal_boundaries):
idf_surface_type = self.idf_surfaces[boundary.parent_surface.type]
outside_boundary_condition = 'Outdoors'
sun_exposure = 'SunExposed'
wind_exposure = 'WindExposed'
_kwargs = {'Name': f'{boundary.parent_surface.name}',
_kwargs = {'Name': f'Building_{building.name}_surface_{index}',
'Surface_Type': idf_surface_type,
'Zone_Name': zone_name}
if boundary.parent_surface.type == cte.GROUND:
@ -694,7 +762,7 @@ class Idf:
wind_exposure = 'NoWind'
if boundary.parent_surface.percentage_shared is not None and boundary.parent_surface.percentage_shared > 0.5:
outside_boundary_condition = 'Surface'
outside_boundary_condition_object = boundary.parent_surface.name
outside_boundary_condition_object = f'Building_{building.name}_surface_{index}'
sun_exposure = 'NoSun'
wind_exposure = 'NoWind'
_kwargs['Outside_Boundary_Condition_Object'] = outside_boundary_condition_object
@ -705,15 +773,13 @@ class Idf:
if boundary.parent_surface.vegetation is not None:
construction_name = f'{boundary.construction_name}_{boundary.parent_surface.vegetation.name}'
else:
construction_name = boundary.construction_name
construction_name = f'{boundary.construction_name} {boundary.parent_surface.type}'
_kwargs['Construction_Name'] = construction_name
start = datetime.datetime.now()
surface = self._idf.newidfobject(self._SURFACE, **_kwargs)
coordinates = self._matrix_to_list(boundary.parent_surface.solid_polygon.coordinates,
self._city.lower_corner)
surface.setcoords(coordinates)
if self._lod >= 3:
for internal_zone in building.internal_zones:
for thermal_zone in internal_zone.thermal_zones_from_internal_zones:
@ -725,7 +791,10 @@ class Idf:
for surface in building.surfaces:
if surface.type == cte.WALL:
wwr = surface.associated_thermal_boundaries[0].window_ratio
self._idf.set_wwr(wwr, construction='window_construction_1')
try:
self._idf.set_wwr(wwr, construction='window_construction_1')
except ValueError:
self._idf.set_wwr(0, construction='window_construction_1')
def _add_windows_by_vertices(self, boundary):
raise NotImplementedError

File diff suppressed because it is too large Load Diff

View File

@ -13,7 +13,7 @@
! HVAC: None.
!
Version,9.5;
Version,24.1;
Timestep,4;

View File

@ -0,0 +1,62 @@
!- Linux Line endings
Version,
24.1; !- Version Identifier
SimulationControl,
No, !- Do Zone Sizing Calculation
No, !- Do System Sizing Calculation
No, !- Do Plant Sizing Calculation
No, !- Run Simulation for Sizing Periods
Yes, !- Run Simulation for Weather File Run Periods
No, !- Do HVAC Sizing Simulation for Sizing Periods
1; !- Maximum Number of HVAC Sizing Simulation Passes
Building,
Buildings in #CITY#, !- Name
0, !- North Axis
Suburbs, !- Terrain
0.04, !- Loads Convergence Tolerance Value
0.4, !- Temperature Convergence Tolerance Value
FullExterior, !- Solar Distribution
25, !- Maximum Number of Warmup Days
6; !- Minimum Number of Warmup Days
Timestep,
4; !- Number of Timesteps per Hour
RunPeriod,
Run Period 1, !- Name
1, !- Begin Month
1, !- Begin Day of Month
, !- Begin Year
12, !- End Month
31, !- End Day of Month
, !- End Year
Tuesday, !- Day of Week for Start Day
Yes, !- Use Weather File Holidays and Special Days
Yes, !- Use Weather File Daylight Saving Period
No, !- Apply Weekend Holiday Rule
Yes, !- Use Weather File Rain Indicators
Yes; !- Use Weather File Snow Indicators
SCHEDULETYPELIMITS,
Any Number, !- Name
, !- Lower Limit Value
, !- Upper Limit Value
, !- Numeric Type
Dimensionless; !- Unit Type
SCHEDULETYPELIMITS,
Fraction, !- Name
0, !- Lower Limit Value
1, !- Upper Limit Value
Continuous, !- Numeric Type
Dimensionless; !- Unit Type
SCHEDULETYPELIMITS,
On/Off, !- Name
0, !- Lower Limit Value
1, !- Upper Limit Value
Discrete, !- Numeric Type
Dimensionless; !- Unit Type

View File

@ -0,0 +1,74 @@
Output:Table:SummaryReports,
AnnualBuildingUtilityPerformanceSummary, !- Report 1 Name
DemandEndUseComponentsSummary, !- Report 2 Name
SensibleHeatGainSummary, !- Report 3 Name
InputVerificationandResultsSummary, !- Report 4 Name
AdaptiveComfortSummary, !- Report 5 Name
Standard62.1Summary, !- Report 6 Name
ClimaticDataSummary, !- Report 7 Name
EquipmentSummary, !- Report 8 Name
EnvelopeSummary, !- Report 9 Name
LightingSummary, !- Report 10 Name
HVACSizingSummary, !- Report 11 Name
SystemSummary, !- Report 12 Name
ComponentSizingSummary, !- Report 13 Name
OutdoorAirSummary, !- Report 14 Name
ObjectCountSummary, !- Report 15 Name
EndUseEnergyConsumptionOtherFuelsMonthly, !- Report 16 Name
PeakEnergyEndUseOtherFuelsMonthly; !- Report 17 Name
OutputControl:Table:Style,
CommaAndHTML, !- Column Separator
JtoKWH; !- Unit Conversion
OUTPUT:VARIABLE,
*, !- Key Value
Zone Ideal Loads Supply Air Total Heating Energy, !- Variable Name
Hourly; !- Reporting Frequency
OUTPUT:VARIABLE,
*, !- Key Value
Zone Ideal Loads Supply Air Total Cooling Energy, !- Variable Name
Hourly; !- Reporting Frequency
OUTPUT:VARIABLE,
*, !- Key Value
Water Use Equipment Heating Rate, !- Variable Name
Hourly; !- Reporting Frequency
OUTPUT:VARIABLE,
*, !- Key Value
Zone Lights Electricity Rate, !- Variable Name
Hourly; !- Reporting Frequency
OUTPUT:VARIABLE,
*, !- Key Value
Other Equipment Electricity Rate, !- Variable Name
Hourly; !- Reporting Frequency
OUTPUT:VARIABLE,
*, !- Key Value
Zone Air Temperature, !- Variable Name
Hourly; !- Reporting Frequency
OUTPUT:VARIABLE,
*, !- Key Value
Zone Air Relative Humidity, !- Variable Name
Hourly; !- Reporting Frequency
Output:Meter,
DISTRICTHEATING:Facility, !- Key Name
hourly; !- Reporting Frequency
Output:Meter,
DISTRICTCOOLING:Facility, !- Key Name
hourly; !- Reporting Frequency
Output:Meter,
InteriorEquipment:Electricity, !- Key Name
hourly; !- Reporting Frequency
Output:Meter,
InteriorLights:Electricity, !- Key Name
hourly; !- Reporting Frequency

View File

@ -0,0 +1,60 @@
import hub.helpers.constants as cte
BUILDING_SURFACE = '\nBUILDINGSURFACE:DETAILED,\n'
WINDOW_SURFACE = '\nFENESTRATIONSURFACE:DETAILED,\n'
COMPACT_SCHEDULE = '\nSCHEDULE:COMPACT,\n'
FILE_SCHEDULE = '\nSCHEDULE:FILE,\n'
NOMASS_MATERIAL = '\nMATERIAL:NOMASS,\n'
SOLID_MATERIAL = '\nMATERIAL,\n'
WINDOW_MATERIAL = '\nWINDOWMATERIAL:SIMPLEGLAZINGSYSTEM,\n'
CONSTRUCTION = '\nCONSTRUCTION,\n'
ZONE = '\nZONE,\n'
GLOBAL_GEOMETRY_RULES = '\nGlobalGeometryRules,\n'
PEOPLE = '\nPEOPLE,\n'
LIGHTS = '\nLIGHTS,\n'
APPLIANCES = '\nOTHEREQUIPMENT,\n'
OUTPUT_CONTROL = '\nOutputControl:IlluminanceMap:Style,\n'
INFILTRATION = '\nZONEINFILTRATION:DESIGNFLOWRATE,\n'
VENTILATION = '\nZONEVENTILATION:DESIGNFLOWRATE,\n'
THERMOSTAT = '\nHVACTEMPLATE:THERMOSTAT,\n'
IDEAL_LOAD_SYSTEM = '\nHVACTEMPLATE:ZONE:IDEALLOADSAIRSYSTEM,\n'
DHW = '\nWATERUSE:EQUIPMENT,\n'
SHADING = '\nSHADING:BUILDING:DETAILED,\n'
AUTOCALCULATE = 'autocalculate'
ROUGHNESS = 'MediumRough'
OUTDOORS = 'Outdoors'
GROUND = 'Ground'
SURFACE = 'Surface'
SUN_EXPOSED = 'SunExposed'
WIND_EXPOSED = 'WindExposed'
NON_SUN_EXPOSED = 'NoSun'
NON_WIND_EXPOSED = 'NoWind'
EMPTY = ''
idf_surfaces_dictionary = {
cte.WALL: 'wall',
cte.GROUND: 'floor',
cte.ROOF: 'roof'
}
idf_type_limits = {
cte.ON_OFF: 'on/off',
cte.FRACTION: 'Fraction',
cte.ANY_NUMBER: 'Any Number',
cte.CONTINUOUS: 'Continuous',
cte.DISCRETE: 'Discrete'
}
idf_day_types = {
cte.MONDAY: 'Monday',
cte.TUESDAY: 'Tuesday',
cte.WEDNESDAY: 'Wednesday',
cte.THURSDAY: 'Thursday',
cte.FRIDAY: 'Friday',
cte.SATURDAY: 'Saturday',
cte.SUNDAY: 'Sunday',
cte.HOLIDAY: 'Holidays',
cte.WINTER_DESIGN_DAY: 'WinterDesignDay',
cte.SUMMER_DESIGN_DAY: 'SummerDesignDay'
}

View File

@ -0,0 +1,26 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfAppliance(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
schedule_name = f'Appliance schedules {thermal_zone.usage_name}'
storeys_number = int(thermal_zone.total_floor_area / thermal_zone.footprint_area)
watts_per_zone_floor_area = thermal_zone.appliances.density * storeys_number
subcategory = f'ELECTRIC EQUIPMENT#{zone_name}#InteriorEquipment'
file = self._files['appliances']
self._write_to_idf_format(file, idf_cte.APPLIANCES)
self._write_to_idf_format(file, zone_name, 'Name')
self._write_to_idf_format(file, 'Electricity', 'Fuel Type')
self._write_to_idf_format(file, zone_name, 'Zone or ZoneList or Space or SpaceList Name')
self._write_to_idf_format(file, schedule_name, 'Schedule Name')
self._write_to_idf_format(file, 'Watts/Area', 'Design Level Calculation Method')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Design Level')
self._write_to_idf_format(file, watts_per_zone_floor_area, 'Power per Zone Floor Area')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Power per Person')
self._write_to_idf_format(file, thermal_zone.appliances.latent_fraction, 'Fraction Latent')
self._write_to_idf_format(file, thermal_zone.appliances.radiative_fraction, 'Fraction Radiant')
self._write_to_idf_format(file, 0, 'Fraction Lost')
self._write_to_idf_format(file, 0, 'Carbon Dioxide Generation Rate')
self._write_to_idf_format(file, subcategory, 'EndUse Subcategory', ';')

View File

@ -0,0 +1,78 @@
import os
from pathlib import Path
import hub.exports.building_energy.idf_helper as idf_cte
class IdfBase:
def __init__(self, city, output_path, idf_file_path, idd_file_path, epw_file_path, target_buildings=None,
_calculate_with_new_infiltration=True):
self._city = city
self._output_path = str(output_path.resolve())
self._output_file_path = str((output_path / f'{city.name}.idf').resolve())
self._file_paths = {
'schedules': str((output_path / 'schedules.idf').resolve()),
'file_schedules': str((output_path / 'file_schedules.idf').resolve()),
'solid_materials': str((output_path / 'solid_materials.idf').resolve()),
'nomass_materials': str((output_path / 'nomass_materials.idf').resolve()),
'window_materials': str((output_path / 'window_materials.idf').resolve()),
'constructions': str((output_path / 'constructions.idf').resolve()),
'zones': str((output_path / 'zones.idf').resolve()),
'surfaces': str((output_path / 'surfaces.idf').resolve()),
'fenestration': str((output_path / 'fenestration.idf').resolve()),
'occupancy': str((output_path / 'occupancy.idf').resolve()),
'lighting': str((output_path / 'lights.idf').resolve()),
'appliances': str((output_path / 'appliances.idf').resolve()),
'shading': str((output_path / 'shading.idf').resolve()),
'infiltration': str((output_path / 'infiltration.idf').resolve()),
'ventilation': str((output_path / 'ventilation.idf').resolve()),
'thermostat': str((output_path / 'thermostat.idf').resolve()),
'ideal_load_system': str((output_path / 'ideal_load_system.idf').resolve()),
'dhw': str((output_path / 'dhw.idf').resolve()),
}
self._files = {}
for key, value in self._file_paths.items():
self._files[key] = open(value, 'w', encoding='UTF-8')
self._idd_file_path = str(idd_file_path)
self._idf_file_path = str(idf_file_path)
self._outputs_file_path = str(Path(idf_file_path).parent / 'outputs.idf')
self._epw_file_path = str(epw_file_path)
self._target_buildings = target_buildings
self._adjacent_buildings = []
if target_buildings is None:
self._target_buildings = [building.name for building in self._city.buildings]
else:
for building_name in target_buildings:
building = city.city_object(building_name)
if building.neighbours is not None:
self._adjacent_buildings += building.neighbours
self._calculate_with_new_infiltration = _calculate_with_new_infiltration
def _create_output_control_lighting(self):
file = self._files['appliances']
self._write_to_idf_format(file, idf_cte.OUTPUT_CONTROL)
self._write_to_idf_format(file, 'Comma', 'Column Separator', ';')
@staticmethod
def _write_to_idf_format(file, field, comment='', eol=','):
if comment != '':
comment = f' !- {comment}'
field = f' {field}{eol}'.ljust(26, ' ')
file.write(f'{field}{comment}\n')
else:
file.write(f'{field}{comment}')
@staticmethod
def _matrix_to_list(points, lower_corner):
lower_x = lower_corner[0]
lower_y = lower_corner[1]
lower_z = lower_corner[2]
points_list = []
for point in points:
point_tuple = (point[0] - lower_x, point[1] - lower_y, point[2] - lower_z)
points_list.append(point_tuple)
return points_list

View File

@ -0,0 +1,56 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.city_model_structure.building_demand.layer import Layer
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfConstruction(IdfBase):
@staticmethod
def _add_solid_material(self, layer):
file = self._files['solid_materials']
self._write_to_idf_format(file, idf_cte.SOLID_MATERIAL)
self._write_to_idf_format(file, layer.material_name, 'Name')
self._write_to_idf_format(file, idf_cte.ROUGHNESS, 'Roughness')
self._write_to_idf_format(file, layer.thickness, 'Thickness')
self._write_to_idf_format(file, layer.conductivity, 'Conductivity')
self._write_to_idf_format(file, layer.density, 'Density')
self._write_to_idf_format(file, layer.specific_heat, 'Specific Heat')
self._write_to_idf_format(file, layer.thermal_absorptance, 'Thermal Absorptance')
self._write_to_idf_format(file, layer.solar_absorptance, 'Solar Absorptance')
self._write_to_idf_format(file, layer.visible_absorptance, 'Visible Absorptance', ';')
@staticmethod
def _add_default_material(self):
layer = Layer()
layer.material_name = 'DefaultMaterial'
layer.thickness = 0.1
layer.conductivity = 0.1
layer.density = 1000
layer.specific_heat = 1000
layer.thermal_absorptance = 0.9
layer.solar_absorptance = 0.9
layer.visible_absorptance = 0.7
IdfConstruction._add_solid_material(self, layer)
return layer
@staticmethod
def add(self, thermal_boundary):
if thermal_boundary.layers is None:
thermal_boundary.layers = [IdfConstruction._add_default_material(self)]
name = f'{thermal_boundary.construction_name} {thermal_boundary.parent_surface.type}'
if name not in self._constructions_added_to_idf:
self._constructions_added_to_idf[name] = True
file = self._files['constructions']
self._write_to_idf_format(file, idf_cte.CONSTRUCTION)
self._write_to_idf_format(file, name, 'Name')
eol = ','
if len(thermal_boundary.layers) == 1:
eol = ';'
self._write_to_idf_format(file, thermal_boundary.layers[0].material_name, 'Outside Layer', eol)
for i in range(1, len(thermal_boundary.layers) - 1):
comment = f'Layer {i + 1}'
material_name = thermal_boundary.layers[i].material_name
if i == len(thermal_boundary.layers) - 2:
eol = ';'
self._write_to_idf_format(file, material_name, comment, eol)

View File

@ -0,0 +1,21 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfDhw(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
peak_flow_rate = thermal_zone.domestic_hot_water.peak_flow * thermal_zone.total_floor_area
flow_rate_schedule = f'DHW_prof schedules {thermal_zone.usage_name}'
dhw_schedule = f'DHW_temp schedules {thermal_zone.usage_name}'
cold_temp_schedule = f'cold_temp schedules {thermal_zone.usage_name}'
file = self._files['dhw']
self._write_to_idf_format(file, idf_cte.DHW)
self._write_to_idf_format(file, zone_name, 'Name')
self._write_to_idf_format(file, zone_name, 'EndUse Subcategory')
self._write_to_idf_format(file, peak_flow_rate, 'Peak Flow Rate')
self._write_to_idf_format(file, flow_rate_schedule, 'Flow Rate Fraction Schedule Name')
self._write_to_idf_format(file, dhw_schedule, 'Target Temperature Schedule Name')
self._write_to_idf_format(file, dhw_schedule, 'Hot Water Supply Temperature Schedule Name')
self._write_to_idf_format(file, cold_temp_schedule, 'Cold Water Supply Temperature Schedule Name')
self._write_to_idf_format(file, zone_name, 'Zone Name', ';')

View File

@ -0,0 +1,30 @@
from pathlib import Path
import hub.helpers.constants as cte
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfFileSchedule(IdfBase):
@staticmethod
def add(self, usage, schedule_type, schedules):
schedule_name = f'{schedule_type} schedules {usage}'
for schedule in schedules:
if schedule_name not in self._schedules_added_to_idf:
self._schedules_added_to_idf[schedule_name] = True
file_name = str(
(Path(self._output_path) / f'{schedule_type} schedules {usage.replace("/", "_")}.csv').resolve())
with open(file_name, 'w', encoding='utf8') as file:
for value in schedule.values[0]:
file.write(f'{value},\n')
file = self._files['file_schedules']
self._write_to_idf_format(file, idf_cte.FILE_SCHEDULE)
self._write_to_idf_format(file, schedule_name, 'Name')
self._write_to_idf_format(file, idf_cte.idf_type_limits[schedule.data_type], 'Schedule Type Limits Name')
self._write_to_idf_format(file, Path(file_name).name, 'File Name')
self._write_to_idf_format(file, 1, 'Column Number')
self._write_to_idf_format(file, 0, 'Rows to Skip at Top')
self._write_to_idf_format(file, 8760, 'Number of Hours of Data')
self._write_to_idf_format(file, 'Comma', 'Column Separator')
self._write_to_idf_format(file, 'No', 'Interpolate to Timestep')
self._write_to_idf_format(file, '60', 'Minutes per Item')
self._write_to_idf_format(file, 'Yes', 'Adjust Schedule for Daylight Savings', ';')

View File

@ -0,0 +1,41 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfHeatingSystem(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
availability_schedule = f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}'
thermostat_name = f'Thermostat {thermal_zone.usage_name}'
file = self._files['ideal_load_system']
self._write_to_idf_format(file, idf_cte.IDEAL_LOAD_SYSTEM)
self._write_to_idf_format(file, zone_name, 'Zone Name')
self._write_to_idf_format(file, thermostat_name, 'Template Thermostat Name')
self._write_to_idf_format(file, availability_schedule, 'System Availability Schedule Name')
self._write_to_idf_format(file, 50, 'Maximum Heating Supply Air Temperature')
self._write_to_idf_format(file, 13, 'Minimum Cooling Supply Air Temperature')
self._write_to_idf_format(file, 0.0156, 'Maximum Heating Supply Air Humidity Ratio')
self._write_to_idf_format(file, 0.0077, 'Minimum Cooling Supply Air Humidity Ratio')
self._write_to_idf_format(file, 'NoLimit', 'Heating Limit')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Maximum Heating Air Flow Rate')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Maximum Sensible Heating Capacity')
self._write_to_idf_format(file, 'NoLimit', 'Cooling Limit')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Maximum Cooling Air Flow Rate')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Maximum Total Cooling Capacity')
self._write_to_idf_format(file, availability_schedule, 'Heating Availability Schedule Name')
self._write_to_idf_format(file, availability_schedule, 'Cooling Availability Schedule Name')
self._write_to_idf_format(file, 'ConstantSensibleHeatRatio', 'Dehumidification Control Type')
self._write_to_idf_format(file, 0.7, 'Cooling Sensible Heat Ratio')
self._write_to_idf_format(file, 60, 'Dehumidification Setpoint')
self._write_to_idf_format(file, 'None', 'Humidification Control Type')
self._write_to_idf_format(file, 30, 'Humidification Setpoint')
self._write_to_idf_format(file, 'None', 'Outdoor Air Method')
self._write_to_idf_format(file, 0.00944, 'Outdoor Air Flow Rate per Person')
self._write_to_idf_format(file, 0.0, 'Outdoor Air Flow Rate per Zone Floor Area')
self._write_to_idf_format(file, 0, 'Outdoor Air Flow Rate per Zone')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Design Specification Outdoor Air Object Name')
self._write_to_idf_format(file, 'None', 'Demand Controlled Ventilation Type')
self._write_to_idf_format(file, 'NoEconomizer', 'Outdoor Air Economizer Type')
self._write_to_idf_format(file, 'None', 'Heat Recovery Type')
self._write_to_idf_format(file, 0.70, 'Sensible Heat Recovery Effectiveness')
self._write_to_idf_format(file, 0.65, 'Latent Heat Recovery Effectiveness', ';')

View File

@ -0,0 +1,32 @@
import hub.exports.building_energy.idf_helper as idf_cte
import hub.helpers.constants as cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfInfiltration(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
IdfInfiltration._add_infiltration(self, thermal_zone, zone_name, 'AirChanges/Hour', cte.HOUR_TO_SECONDS)
@staticmethod
def add_surface(self, thermal_zone, zone_name):
IdfInfiltration._add_infiltration(self, thermal_zone, zone_name, 'Flow/ExteriorWallArea', cte.INFILTRATION_75PA_TO_4PA)
@staticmethod
def _add_infiltration(self, thermal_zone, zone_name, calculation_method, multiplier):
schedule_name = f'Infiltration schedules {thermal_zone.usage_name}'
infiltration = thermal_zone.infiltration_rate_system_off * multiplier
file = self._files['infiltration']
self._write_to_idf_format(file, idf_cte.INFILTRATION)
self._write_to_idf_format(file, zone_name, 'Name')
self._write_to_idf_format(file, zone_name, 'Zone or ZoneList or Space or SpaceList Name')
self._write_to_idf_format(file, schedule_name, 'Schedule Name')
self._write_to_idf_format(file, calculation_method, 'Design Flow Rate Calculation Method')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Design Flow Rate')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Flow Rate per Floor Area')
self._write_to_idf_format(file, infiltration, 'Flow Rate per Exterior Surface Area')
self._write_to_idf_format(file, infiltration, 'Air Changes per Hour')
self._write_to_idf_format(file, 1, 'Constant Term Coefficient')
self._write_to_idf_format(file, 0, 'Temperature Term Coefficient')
self._write_to_idf_format(file, 0, 'Velocity Term Coefficient')
self._write_to_idf_format(file, 0, 'Velocity Squared Term Coefficient', ';')

View File

@ -0,0 +1,28 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfLighting(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
storeys_number = int(thermal_zone.total_floor_area / thermal_zone.footprint_area)
watts_per_zone_floor_area = thermal_zone.lighting.density * storeys_number
subcategory = f'ELECTRIC EQUIPMENT#{zone_name}#GeneralLights'
schedule_name = f'Lighting schedules {thermal_zone.usage_name}'
file = self._files['lighting']
self._write_to_idf_format(file, idf_cte.LIGHTS)
self._write_to_idf_format(file, f'{zone_name}_lights', 'Name')
self._write_to_idf_format(file, zone_name, 'Zone or ZoneList or Space or SpaceList Name')
self._write_to_idf_format(file, schedule_name, 'Schedule Name')
self._write_to_idf_format(file, 'Watts/Area', 'Design Level Calculation Method')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Lighting Level')
self._write_to_idf_format(file, watts_per_zone_floor_area, 'Watts per Zone Floor Area')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Watts per Person')
self._write_to_idf_format(file, 0, 'Return Air Fraction')
self._write_to_idf_format(file, thermal_zone.lighting.radiative_fraction, 'Fraction Radiant')
self._write_to_idf_format(file, 0, 'Fraction Visible')
self._write_to_idf_format(file, 1, 'Fraction Replaceable')
self._write_to_idf_format(file, subcategory, 'EndUse Subcategory')
self._write_to_idf_format(file, 'No', 'Return Air Fraction Calculated from Plenum Temperature')
self._write_to_idf_format(file, 0, 'Return Air Fraction Function of Plenum Temperature Coefficient 1')
self._write_to_idf_format(file, 0, 'Return Air Fraction Function of Plenum Temperature Coefficient 2', ';')

View File

@ -0,0 +1,39 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfMaterial(IdfBase):
@staticmethod
def _add_solid_material(self, layer):
file = self._files['solid_materials']
self._write_to_idf_format(file, idf_cte.SOLID_MATERIAL)
self._write_to_idf_format(file, layer.material_name, 'Name')
self._write_to_idf_format(file, idf_cte.ROUGHNESS, 'Roughness')
self._write_to_idf_format(file, layer.thickness, 'Thickness')
self._write_to_idf_format(file, layer.conductivity, 'Conductivity')
self._write_to_idf_format(file, layer.density, 'Density')
self._write_to_idf_format(file, layer.specific_heat, 'Specific Heat')
self._write_to_idf_format(file, layer.thermal_absorptance, 'Thermal Absorptance')
self._write_to_idf_format(file, layer.solar_absorptance, 'Solar Absorptance')
self._write_to_idf_format(file, layer.visible_absorptance, 'Visible Absorptance', ';')
@staticmethod
def _add_nomass_material(self, layer):
file = self._files['nomass_materials']
self._write_to_idf_format(file, idf_cte.NOMASS_MATERIAL)
self._write_to_idf_format(file, layer.material_name, 'Name')
self._write_to_idf_format(file, idf_cte.ROUGHNESS, 'Roughness')
self._write_to_idf_format(file, layer.thermal_resistance, 'Thermal Resistance')
self._write_to_idf_format(file, 0.9, 'Thermal Absorptance')
self._write_to_idf_format(file, 0.7, 'Solar Absorptance')
self._write_to_idf_format(file, 0.7, 'Visible Absorptance', ';')
@staticmethod
def add(self, thermal_boundary):
for layer in thermal_boundary.layers:
if layer.material_name not in self._materials_added_to_idf:
self._materials_added_to_idf[layer.material_name] = True
if layer.no_mass:
IdfMaterial._add_nomass_material(self, layer)
else:
IdfMaterial._add_solid_material(self, layer)

View File

@ -0,0 +1,47 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfOccupancy(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
number_of_people = thermal_zone.occupancy.occupancy_density * thermal_zone.total_floor_area
fraction_radiant = 0
total_sensible = (
thermal_zone.occupancy.sensible_radiative_internal_gain + thermal_zone.occupancy.sensible_convective_internal_gain
)
if total_sensible != 0:
fraction_radiant = thermal_zone.occupancy.sensible_radiative_internal_gain / total_sensible
occupancy_schedule = f'Occupancy schedules {thermal_zone.usage_name}'
activity_level_schedule = f'Activity Level schedules {thermal_zone.usage_name}'
file = self._files['occupancy']
self._write_to_idf_format(file, idf_cte.PEOPLE)
self._write_to_idf_format(file, f'{zone_name}_occupancy', 'Name')
self._write_to_idf_format(file, zone_name, 'Zone or ZoneList or Space or SpaceList Name')
self._write_to_idf_format(file, occupancy_schedule, 'Number of People Schedule Name')
self._write_to_idf_format(file, 'People', 'Number of People Calculation Method')
self._write_to_idf_format(file, number_of_people, 'Number of People')
self._write_to_idf_format(file, idf_cte.EMPTY, 'People per Floor Area')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Floor Area per Person')
self._write_to_idf_format(file, fraction_radiant, 'Fraction Radiant')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'Sensible Heat Fraction')
self._write_to_idf_format(file, activity_level_schedule, 'Activity Level Schedule Name')
self._write_to_idf_format(file, '3.82e-08', 'Carbon Dioxide Generation Rate')
self._write_to_idf_format(file, 'No', 'Enable ASHRAE 55 Comfort Warnings')
self._write_to_idf_format(file, 'EnclosureAveraged', 'Mean Radiant Temperature Calculation Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Surface NameAngle Factor List Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Work Efficiency Schedule Name')
self._write_to_idf_format(file, 'ClothingInsulationSchedule', 'Clothing Insulation Calculation Method')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Clothing Insulation Calculation Method Schedule Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Clothing Insulation Schedule Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Air Velocity Schedule Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 1 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 2 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 3 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 4 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 5 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 6 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Thermal Comfort Model 7 Type')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Ankle Level Air Velocity Schedule Name')
self._write_to_idf_format(file, '15.56', 'Cold Stress Temperature Threshold')
self._write_to_idf_format(file, '30', 'Heat Stress Temperature Threshold', ';')

View File

@ -0,0 +1,30 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfSchedule(IdfBase):
@staticmethod
def add(self, usage, schedule_type, schedules):
if len(schedules) < 1:
return
schedule_name = f'{schedule_type} schedules {usage}'
if schedule_name not in self._schedules_added_to_idf:
self._schedules_added_to_idf[schedule_name] = True
file = self._files['schedules']
self._write_to_idf_format(file, idf_cte.COMPACT_SCHEDULE)
self._write_to_idf_format(file, schedule_name, 'Name')
self._write_to_idf_format(file, idf_cte.idf_type_limits[schedules[0].data_type], 'Schedule Type Limits Name')
self._write_to_idf_format(file, 'Through: 12/31', 'Field 1')
counter = 1
for j, schedule in enumerate(schedules):
_val = schedule.values
_new_field = ''
for day_type in schedule.day_types:
_new_field += f' {idf_cte.idf_day_types[day_type]}'
self._write_to_idf_format(file, f'For:{_new_field}', f'Field {j * 25 + 2}')
counter += 1
for i, _ in enumerate(_val):
self._write_to_idf_format(file, f'Until: {i + 1:02d}:00,{_val[i]}', f'Field {j * 25 + 3 + i}')
counter += 1
self._write_to_idf_format(file, 'For AllOtherDays', f'Field {counter + 1}')
self._write_to_idf_format(file, 'Until: 24:00,0.0', f'Field {counter + 2}', ';')

View File

@ -0,0 +1,25 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfShading(IdfBase):
@staticmethod
def add(self, building):
name = building.name
file = self._files['shading']
for s, surface in enumerate(building.surfaces):
self._write_to_idf_format(file, idf_cte.SHADING)
self._write_to_idf_format(file, f'{name}_{s}', 'Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Transmittance Schedule Name')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'Number of Vertices')
eol = ','
coordinates = self._matrix_to_list(surface.solid_polygon.coordinates, self._city.lower_corner)
coordinates_length = len(coordinates)
for i, coordinate in enumerate(coordinates):
vertex = i + 1
if vertex == coordinates_length:
eol = ';'
self._write_to_idf_format(file, coordinate[0], f'Vertex {vertex} Xcoordinate')
self._write_to_idf_format(file, coordinate[1], f'Vertex {vertex} Ycoordinate')
self._write_to_idf_format(file, coordinate[2], f'Vertex {vertex} Zcoordinate', eol)

View File

@ -0,0 +1,52 @@
import hub.exports.building_energy.idf_helper as idf_cte
import hub.helpers.constants as cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfSurfaces(IdfBase):
@staticmethod
def add(self, building, zone_name):
zone_name = f'{zone_name}'
file = self._files['surfaces']
for thermal_zone in building.thermal_zones_from_internal_zones:
for index, boundary in enumerate(thermal_zone.thermal_boundaries):
surface_type = idf_cte.idf_surfaces_dictionary[boundary.parent_surface.type]
outside_boundary_condition = idf_cte.OUTDOORS
sun_exposure = idf_cte.SUN_EXPOSED
wind_exposure = idf_cte.WIND_EXPOSED
outside_boundary_condition_object = idf_cte.EMPTY
name = f'Building_{building.name}_surface_{index}'
construction_name = f'{boundary.construction_name} {boundary.parent_surface.type}'
space_name = idf_cte.EMPTY
if boundary.parent_surface.type == cte.GROUND:
outside_boundary_condition = idf_cte.GROUND
sun_exposure = idf_cte.NON_SUN_EXPOSED
wind_exposure = idf_cte.NON_WIND_EXPOSED
if boundary.parent_surface.percentage_shared is not None and boundary.parent_surface.percentage_shared > 0.5:
outside_boundary_condition_object = f'Building_{building.name}_surface_{index}'
outside_boundary_condition = idf_cte.SURFACE
sun_exposure = idf_cte.NON_SUN_EXPOSED
wind_exposure = idf_cte.NON_WIND_EXPOSED
self._write_to_idf_format(file, idf_cte.BUILDING_SURFACE)
self._write_to_idf_format(file, name, 'Name')
self._write_to_idf_format(file, surface_type, 'Surface Type')
self._write_to_idf_format(file, construction_name, 'Construction Name')
self._write_to_idf_format(file, zone_name, 'Zone Name')
self._write_to_idf_format(file, space_name, 'Space Name')
self._write_to_idf_format(file, outside_boundary_condition, 'Outside Boundary Condition')
self._write_to_idf_format(file, outside_boundary_condition_object, 'Outside Boundary Condition Object')
self._write_to_idf_format(file, sun_exposure, 'Sun Exposure')
self._write_to_idf_format(file, wind_exposure, 'Wind Exposure')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'View Factor to Ground')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'Number of Vertices')
coordinates = self._matrix_to_list(boundary.parent_surface.solid_polygon.coordinates,
self._city.lower_corner)
eol = ','
coordinates_length = len(coordinates)
for i, coordinate in enumerate(coordinates):
vertex = i + 1
if vertex == coordinates_length:
eol = ';'
self._write_to_idf_format(file, coordinate[0], f'Vertex {vertex} Xcoordinate')
self._write_to_idf_format(file, coordinate[1], f'Vertex {vertex} Ycoordinate')
self._write_to_idf_format(file, coordinate[2], f'Vertex {vertex} Zcoordinate', eol)

View File

@ -0,0 +1,18 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfThermostat(IdfBase):
@staticmethod
def add(self, thermal_zone):
thermostat_name = f'Thermostat {thermal_zone.usage_name}'
heating_schedule = f'Heating thermostat schedules {thermal_zone.usage_name}'
cooling_schedule = f'Cooling thermostat schedules {thermal_zone.usage_name}'
if thermostat_name not in self._thermostat_added_to_idf:
self._thermostat_added_to_idf[thermostat_name] = True
file = self._files['thermostat']
self._write_to_idf_format(file, idf_cte.THERMOSTAT)
self._write_to_idf_format(file, thermostat_name, 'Name')
self._write_to_idf_format(file, heating_schedule, 'Heating Setpoint Schedule Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Constant Heating Setpoint')
self._write_to_idf_format(file, cooling_schedule, 'Cooling Setpoint Schedule Name', ';')

View File

@ -0,0 +1,38 @@
import hub.exports.building_energy.idf_helper as idf_cte
import hub.helpers.constants as cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfVentilation(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
schedule_name = f'Ventilation schedules {thermal_zone.usage_name}'
air_change = thermal_zone.mechanical_air_change * cte.HOUR_TO_SECONDS
file = self._files['ventilation']
self._write_to_idf_format(file, idf_cte.VENTILATION)
self._write_to_idf_format(file, f'{zone_name}_ventilation', 'Name')
self._write_to_idf_format(file, zone_name, 'Zone or ZoneList or Space or SpaceList Name')
self._write_to_idf_format(file, schedule_name, 'Schedule Name')
self._write_to_idf_format(file, 'AirChanges/Hour', 'Design Flow Rate Calculation Method')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Design Flow Rate')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Flow Rate per Floor Area')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Flow Rate per Person')
self._write_to_idf_format(file, air_change, 'Air Changes per Hour')
self._write_to_idf_format(file, 'Natural', 'Ventilation Type')
self._write_to_idf_format(file, 0, 'Fan Pressure Rise')
self._write_to_idf_format(file, 1, 'Fan Total Efficiency')
self._write_to_idf_format(file, 1, 'Constant Term Coefficient')
self._write_to_idf_format(file, 0, 'Temperature Term Coefficient')
self._write_to_idf_format(file, 0, 'Velocity Term Coefficient')
self._write_to_idf_format(file, 0, 'Velocity Squared Term Coefficient')
self._write_to_idf_format(file, -100, 'Minimum Indoor Temperature')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Minimum Indoor Temperature Schedule Name')
self._write_to_idf_format(file, 100, 'Maximum Indoor Temperature')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Maximum Indoor Temperature Schedule Name')
self._write_to_idf_format(file, -100, 'Delta Temperature')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Delta Temperature Schedule Name')
self._write_to_idf_format(file, -100, 'Minimum Outdoor Temperature')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Minimum Outdoor Temperature Schedule Name')
self._write_to_idf_format(file, 100, 'Maximum Outdoor Temperature')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Maximum Outdoor Temperature Schedule Name')
self._write_to_idf_format(file, 40, 'Maximum Wind Speed', ';')

View File

@ -0,0 +1,64 @@
import logging
import hub.exports.building_energy.idf_helper as idf_cte
import hub.helpers.constants as cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfWindow(IdfBase):
@staticmethod
def _to_window_surface(self, surface):
window_ratio = surface.associated_thermal_boundaries[0].window_ratio
x = 0
y = 1
z = 2
coordinates = self._matrix_to_list(surface.solid_polygon.coordinates, self._city.lower_corner)
min_z = surface.lower_corner[z]
max_z = surface.upper_corner[z]
middle = (max_z - min_z) / 2
distance = (max_z - min_z) * window_ratio
new_max_z = middle + distance / 2
new_min_z = middle - distance / 2
for index, coordinate in enumerate(coordinates):
if coordinate[z] == max_z:
coordinates[index] = (coordinate[x], coordinate[y], new_max_z)
elif coordinate[z] == min_z:
coordinates[index] = (coordinate[x], coordinate[y], new_min_z)
else:
logging.warning('Z coordinate not in top or bottom during window creation')
return coordinates
@staticmethod
def add(self, building):
file = self._files['fenestration']
for thermal_zone in building.thermal_zones_from_internal_zones:
for index, boundary in enumerate(thermal_zone.thermal_boundaries):
building_surface_name = f'Building_{building.name}_surface_{index}'
is_exposed = boundary.parent_surface.type == cte.WALL
if boundary.parent_surface.percentage_shared is not None and boundary.parent_surface.percentage_shared > 0.5 or boundary.window_ratio == 0:
is_exposed = False
if not is_exposed:
continue
name = f'Building_{building.name}_window_{index}'
construction_name = f'{boundary.construction_name}_window_construction'
self._write_to_idf_format(file, idf_cte.WINDOW_SURFACE)
self._write_to_idf_format(file, name, 'Name')
self._write_to_idf_format(file, 'Window', 'Surface Type')
self._write_to_idf_format(file, construction_name, 'Construction Name')
self._write_to_idf_format(file, building_surface_name, 'Building Surface Name')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Outside Boundary Condition Object')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'View Factor to Ground')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Frame and Divider Name')
self._write_to_idf_format(file, '1.0', 'Multiplier')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'Number of Vertices')
coordinates = IdfWindow._to_window_surface(self, boundary.parent_surface)
eol = ','
coordinates_length = len(coordinates)
for i, coordinate in enumerate(coordinates):
vertex = i + 1
if vertex == coordinates_length:
eol = ';'
self._write_to_idf_format(file, coordinate[0], f'Vertex {vertex} Xcoordinate')
self._write_to_idf_format(file, coordinate[1], f'Vertex {vertex} Ycoordinate')
self._write_to_idf_format(file, coordinate[2], f'Vertex {vertex} Zcoordinate', eol)

View File

@ -0,0 +1,17 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfWindowsConstructions(IdfBase):
@staticmethod
def add(self, thermal_boundary):
name = f'{thermal_boundary.construction_name}_window'
if name not in self._windows_added_to_idf:
return # Material not added or already assigned to construction
construction_name = f'{thermal_boundary.construction_name}_window_construction'
if construction_name not in self._constructions_added_to_idf:
self._constructions_added_to_idf[construction_name] = True
file = self._files['constructions']
self._write_to_idf_format(file, idf_cte.CONSTRUCTION)
self._write_to_idf_format(file, construction_name, 'Name')
self._write_to_idf_format(file, name, 'Outside Layer', ';')

View File

@ -0,0 +1,15 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfWindowsMaterial(IdfBase):
@staticmethod
def add(self, thermal_boundary, thermal_opening):
name = f'{thermal_boundary.construction_name}_window'
if name not in self._windows_added_to_idf:
self._windows_added_to_idf[name] = True
file = self._files['window_materials']
self._write_to_idf_format(file, idf_cte.WINDOW_MATERIAL)
self._write_to_idf_format(file, name, 'Name')
self._write_to_idf_format(file, thermal_opening.overall_u_value, 'UFactor')
self._write_to_idf_format(file, thermal_opening.g_value, 'Solar Heat Gain Coefficient', ';')

View File

@ -0,0 +1,22 @@
import hub.exports.building_energy.idf_helper as idf_cte
from hub.exports.building_energy.idf_helper.idf_base import IdfBase
class IdfZone(IdfBase):
@staticmethod
def add(self, thermal_zone, zone_name):
file = self._files['zones']
self._write_to_idf_format(file, idf_cte.ZONE)
self._write_to_idf_format(file, zone_name, 'Name')
self._write_to_idf_format(file, 0, 'Direction of Relative North')
self._write_to_idf_format(file, 0, 'X Origin')
self._write_to_idf_format(file, 0, 'Y Origin')
self._write_to_idf_format(file, 0, 'Z Origin')
self._write_to_idf_format(file, 1, 'Type')
self._write_to_idf_format(file, 1, 'Multiplier')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'Ceiling Height')
self._write_to_idf_format(file, thermal_zone.volume, 'Volume')
self._write_to_idf_format(file, idf_cte.AUTOCALCULATE, 'Floor Area')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Zone Inside Convection Algorithm')
self._write_to_idf_format(file, idf_cte.EMPTY, 'Zone Outside Convection Algorithm')
self._write_to_idf_format(file, 'Yes', 'Part of Total Floor Area', ';')

View File

@ -270,7 +270,7 @@ class InselMonthlyEnergyBalance:
global_irradiance = surface.global_irradiance[cte.MONTH]
for j in range(0, len(global_irradiance)):
parameters.append(f'{j + 1} '
f'{global_irradiance[j] * cte.WATTS_HOUR_TO_JULES / 24 / _NUMBER_DAYS_PER_MONTH[j]}')
f'{global_irradiance[j] / 24 / _NUMBER_DAYS_PER_MONTH[j]}')
else:
for j in range(0, 12):
parameters.append(f'{j + 1} 0.0')

Some files were not shown because too many files have changed in this diff Show More