Merge pull request 'oriol_changes' (#20) from oriol_changes into main
Reviewed-on: #20
This commit is contained in:
commit
b6ec189207
2
.gitignore
vendored
2
.gitignore
vendored
|
@ -12,3 +12,5 @@
|
|||
cerc_hub.egg-info
|
||||
/out_files
|
||||
/input_files/output_buildings.geojson
|
||||
*/.pyc
|
||||
*.pyc
|
||||
|
|
|
@ -22,6 +22,7 @@ class EilatCatalog(Catalog):
|
|||
"""
|
||||
Eilat catalog class
|
||||
"""
|
||||
|
||||
def __init__(self, path):
|
||||
_path_archetypes = Path(path / 'eilat_archetypes.json').resolve()
|
||||
_path_constructions = (path / 'eilat_constructions.json').resolve()
|
||||
|
@ -121,8 +122,14 @@ class EilatCatalog(Catalog):
|
|||
construction_period = archetype['period_of_construction']
|
||||
average_storey_height = archetype['average_storey_height']
|
||||
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
|
||||
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_for_ventilation_system_off = archetype[
|
||||
'infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_for_ventilation_system_on = archetype[
|
||||
'infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_area_for_ventilation_system_off = archetype[
|
||||
'infiltration_rate_area_for_ventilation_system_off']
|
||||
infiltration_rate_area_for_ventilation_system_on = archetype[
|
||||
'infiltration_rate_area_for_ventilation_system_on']
|
||||
|
||||
archetype_constructions = []
|
||||
for archetype_construction in archetype['constructions']:
|
||||
|
@ -160,7 +167,9 @@ class EilatCatalog(Catalog):
|
|||
extra_loses_due_to_thermal_bridges,
|
||||
None,
|
||||
infiltration_rate_for_ventilation_system_off,
|
||||
infiltration_rate_for_ventilation_system_on))
|
||||
infiltration_rate_for_ventilation_system_on,
|
||||
infiltration_rate_area_for_ventilation_system_off,
|
||||
infiltration_rate_area_for_ventilation_system_on))
|
||||
return _catalog_archetypes
|
||||
|
||||
def names(self, category=None):
|
||||
|
|
|
@ -128,6 +128,12 @@ class NrcanCatalog(Catalog):
|
|||
infiltration_rate_for_ventilation_system_on = (
|
||||
archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
|
||||
)
|
||||
infiltration_rate_area_for_ventilation_system_off = (
|
||||
archetype['infiltration_rate_area_for_ventilation_system_off'] * 1
|
||||
)
|
||||
infiltration_rate_area_for_ventilation_system_on = (
|
||||
archetype['infiltration_rate_area_for_ventilation_system_on'] * 1
|
||||
)
|
||||
|
||||
archetype_constructions = []
|
||||
for archetype_construction in archetype['constructions']:
|
||||
|
@ -153,7 +159,6 @@ class NrcanCatalog(Catalog):
|
|||
_window)
|
||||
archetype_constructions.append(_construction)
|
||||
break
|
||||
|
||||
_catalog_archetypes.append(Archetype(archetype_id,
|
||||
name,
|
||||
function,
|
||||
|
@ -165,7 +170,10 @@ class NrcanCatalog(Catalog):
|
|||
extra_loses_due_to_thermal_bridges,
|
||||
None,
|
||||
infiltration_rate_for_ventilation_system_off,
|
||||
infiltration_rate_for_ventilation_system_on))
|
||||
infiltration_rate_for_ventilation_system_on,
|
||||
infiltration_rate_area_for_ventilation_system_off,
|
||||
infiltration_rate_area_for_ventilation_system_on
|
||||
))
|
||||
return _catalog_archetypes
|
||||
|
||||
def names(self, category=None):
|
||||
|
|
|
@ -129,6 +129,12 @@ class NrelCatalog(Catalog):
|
|||
infiltration_rate_for_ventilation_system_on = float(
|
||||
archetype['infiltration_rate_for_ventilation_system_on']['#text']
|
||||
) / cte.HOUR_TO_SECONDS
|
||||
infiltration_rate_area_for_ventilation_system_off = float(
|
||||
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
|
||||
)
|
||||
infiltration_rate_area_for_ventilation_system_on = float(
|
||||
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
|
||||
)
|
||||
|
||||
archetype_constructions = []
|
||||
for archetype_construction in archetype['constructions']['construction']:
|
||||
|
@ -162,7 +168,9 @@ class NrelCatalog(Catalog):
|
|||
extra_loses_due_to_thermal_bridges,
|
||||
indirect_heated_ratio,
|
||||
infiltration_rate_for_ventilation_system_off,
|
||||
infiltration_rate_for_ventilation_system_on))
|
||||
infiltration_rate_for_ventilation_system_on,
|
||||
infiltration_rate_area_for_ventilation_system_off,
|
||||
infiltration_rate_area_for_ventilation_system_on))
|
||||
return _catalog_archetypes
|
||||
|
||||
def names(self, category=None):
|
||||
|
|
|
@ -23,7 +23,10 @@ class Archetype:
|
|||
extra_loses_due_to_thermal_bridges,
|
||||
indirect_heated_ratio,
|
||||
infiltration_rate_for_ventilation_system_off,
|
||||
infiltration_rate_for_ventilation_system_on):
|
||||
infiltration_rate_for_ventilation_system_on,
|
||||
infiltration_rate_area_for_ventilation_system_off,
|
||||
infiltration_rate_area_for_ventilation_system_on
|
||||
):
|
||||
self._id = archetype_id
|
||||
self._name = name
|
||||
self._function = function
|
||||
|
@ -36,6 +39,8 @@ class Archetype:
|
|||
self._indirect_heated_ratio = indirect_heated_ratio
|
||||
self._infiltration_rate_for_ventilation_system_off = infiltration_rate_for_ventilation_system_off
|
||||
self._infiltration_rate_for_ventilation_system_on = infiltration_rate_for_ventilation_system_on
|
||||
self._infiltration_rate_area_for_ventilation_system_off = infiltration_rate_area_for_ventilation_system_off
|
||||
self._infiltration_rate_area_for_ventilation_system_on = infiltration_rate_area_for_ventilation_system_on
|
||||
|
||||
@property
|
||||
def id(self):
|
||||
|
@ -133,6 +138,22 @@ class Archetype:
|
|||
"""
|
||||
return self._infiltration_rate_for_ventilation_system_on
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_for_ventilation_system_off(self):
|
||||
"""
|
||||
Get archetype infiltration rate for ventilation system off in m3/sm2
|
||||
:return: float
|
||||
"""
|
||||
return self._infiltration_rate_area_for_ventilation_system_off
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_for_ventilation_system_on(self):
|
||||
"""
|
||||
Get archetype infiltration rate for ventilation system on in m3/sm2
|
||||
:return: float
|
||||
"""
|
||||
return self._infiltration_rate_for_ventilation_system_on
|
||||
|
||||
def to_dictionary(self):
|
||||
"""Class content to dictionary"""
|
||||
_constructions = []
|
||||
|
@ -149,6 +170,8 @@ class Archetype:
|
|||
'indirect heated ratio': self.indirect_heated_ratio,
|
||||
'infiltration rate for ventilation off [1/s]': self.infiltration_rate_for_ventilation_system_off,
|
||||
'infiltration rate for ventilation on [1/s]': self.infiltration_rate_for_ventilation_system_on,
|
||||
'infiltration rate area for ventilation off [m3/sm2]': self.infiltration_rate_area_for_ventilation_system_off,
|
||||
'infiltration rate area for ventilation on [m3/sm2]': self.infiltration_rate_area_for_ventilation_system_on,
|
||||
'constructions': _constructions
|
||||
}
|
||||
}
|
||||
|
|
|
@ -132,6 +132,8 @@ class InternalZone:
|
|||
_thermal_boundary = ThermalBoundary(surface, surface.solid_polygon.area, windows_areas)
|
||||
surface.associated_thermal_boundaries = [_thermal_boundary]
|
||||
_thermal_boundaries.append(_thermal_boundary)
|
||||
if self.thermal_archetype is None:
|
||||
return None # there are no archetype
|
||||
_number_of_storeys = int(self.volume / self.area / self.thermal_archetype.average_storey_height)
|
||||
_thermal_zone = ThermalZone(_thermal_boundaries, self, self.volume, self.area, _number_of_storeys)
|
||||
for thermal_boundary in _thermal_zone.thermal_boundaries:
|
||||
|
|
|
@ -18,6 +18,7 @@ from hub.city_model_structure.attributes.point import Point
|
|||
from hub.city_model_structure.greenery.vegetation import Vegetation
|
||||
from hub.city_model_structure.building_demand.thermal_boundary import ThermalBoundary
|
||||
import hub.helpers.constants as cte
|
||||
from hub.helpers.configuration_helper import ConfigurationHelper
|
||||
|
||||
|
||||
class Surface:
|
||||
|
@ -41,7 +42,7 @@ class Surface:
|
|||
self._short_wave_reflectance = None
|
||||
self._long_wave_emittance = None
|
||||
self._inverse = None
|
||||
self._associated_thermal_boundaries = []
|
||||
self._associated_thermal_boundaries = None
|
||||
self._vegetation = None
|
||||
self._percentage_shared = None
|
||||
self._solar_collectors_area_reduction_factor = None
|
||||
|
@ -167,10 +168,10 @@ class Surface:
|
|||
"""
|
||||
if self._type is None:
|
||||
inclination_cos = math.cos(self.inclination)
|
||||
# 170 degrees
|
||||
# 170 degrees
|
||||
if inclination_cos <= -0.98:
|
||||
self._type = 'Ground'
|
||||
# between 80 and 100 degrees
|
||||
# between 80 and 100 degrees
|
||||
elif abs(inclination_cos) <= 0.17:
|
||||
self._type = 'Wall'
|
||||
else:
|
||||
|
@ -365,12 +366,12 @@ class Surface:
|
|||
_protected_building_restriction = 1
|
||||
# 10 degrees range
|
||||
if abs(math.sin(self.inclination)) < 0.17:
|
||||
# horizontal
|
||||
# horizontal
|
||||
_construction_restriction = 0.8
|
||||
_separation_of_panels = 0.46
|
||||
_shadow_between_panels = 0.7
|
||||
else:
|
||||
# tilted
|
||||
# tilted
|
||||
_construction_restriction = 0.9
|
||||
_separation_of_panels = 0.9
|
||||
_shadow_between_panels = 1
|
||||
|
@ -417,4 +418,4 @@ class Surface:
|
|||
Set installed solar collector area in m2
|
||||
:return: dict
|
||||
"""
|
||||
self._installed_solar_collector_area = value
|
||||
self._installed_solar_collector_area = value
|
|
@ -20,6 +20,8 @@ class ThermalArchetype:
|
|||
self._indirect_heated_ratio = None
|
||||
self._infiltration_rate_for_ventilation_system_off = None
|
||||
self._infiltration_rate_for_ventilation_system_on = None
|
||||
self._infiltration_rate_area_for_ventilation_system_off = None
|
||||
self._infiltration_rate_area_for_ventilation_system_on = None
|
||||
|
||||
@property
|
||||
def constructions(self) -> [Construction]:
|
||||
|
@ -132,3 +134,35 @@ class ThermalArchetype:
|
|||
:param value: float
|
||||
"""
|
||||
self._infiltration_rate_for_ventilation_system_on = value
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_for_ventilation_system_off(self):
|
||||
"""
|
||||
Get infiltration rate for ventilation system off in l/s/m2
|
||||
:return: float
|
||||
"""
|
||||
return self._infiltration_rate_area_for_ventilation_system_off
|
||||
|
||||
@infiltration_rate_area_for_ventilation_system_off.setter
|
||||
def infiltration_rate_area_for_ventilation_system_off(self, value):
|
||||
"""
|
||||
Set infiltration rate for ventilation system off in l/s/m2
|
||||
:param value: float
|
||||
"""
|
||||
self._infiltration_rate_area_for_ventilation_system_off = value
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_for_ventilation_system_on(self):
|
||||
"""
|
||||
Get infiltration rate for ventilation system on in l/s/m2
|
||||
:return: float
|
||||
"""
|
||||
return self._infiltration_rate_area_for_ventilation_system_on
|
||||
|
||||
@infiltration_rate_area_for_ventilation_system_on.setter
|
||||
def infiltration_rate_area_for_ventilation_system_on(self, value):
|
||||
"""
|
||||
Set infiltration rate for ventilation system on in l/s/m2
|
||||
:param value: float
|
||||
"""
|
||||
self._infiltration_rate_area_for_ventilation_system_on = value
|
||||
|
|
|
@ -44,6 +44,8 @@ class ThermalZone:
|
|||
self._indirectly_heated_area_ratio = None
|
||||
self._infiltration_rate_system_on = None
|
||||
self._infiltration_rate_system_off = None
|
||||
self._infiltration_rate_area_system_on = None
|
||||
self._infiltration_rate_area_system_off = None
|
||||
self._volume = volume
|
||||
self._ordinate_number = None
|
||||
self._view_factors_matrix = None
|
||||
|
@ -166,6 +168,24 @@ class ThermalZone:
|
|||
self._infiltration_rate_system_off = self._parent_internal_zone.thermal_archetype.infiltration_rate_for_ventilation_system_off
|
||||
return self._infiltration_rate_system_off
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_system_on(self):
|
||||
"""
|
||||
Get thermal zone infiltration rate system on in air changes per second (1/s)
|
||||
:return: None or float
|
||||
"""
|
||||
self._infiltration_rate_area_system_on = self._parent_internal_zone.thermal_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||
return self._infiltration_rate_area_system_on
|
||||
|
||||
@property
|
||||
def infiltration_rate_area_system_off(self):
|
||||
"""
|
||||
Get thermal zone infiltration rate system off in air changes per second (1/s)
|
||||
:return: None or float
|
||||
"""
|
||||
self._infiltration_rate_area_system_off = self._parent_internal_zone.thermal_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||
return self._infiltration_rate_area_system_off
|
||||
|
||||
@property
|
||||
def volume(self):
|
||||
"""
|
||||
|
|
|
@ -8,6 +8,8 @@
|
|||
"extra_loses_due_thermal_bridges": 0.1,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.9,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.006,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "residential_1000_1980_BWh",
|
||||
|
@ -42,6 +44,8 @@
|
|||
"extra_loses_due_thermal_bridges": 0.1,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.31,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.002,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "dormitory_2011_3000_BWh",
|
||||
|
@ -76,6 +80,8 @@
|
|||
"extra_loses_due_thermal_bridges": 0.09,
|
||||
"infiltration_rate_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_for_ventilation_system_off": 0.65,
|
||||
"infiltration_rate_area_for_ventilation_system_on": 0,
|
||||
"infiltration_rate_area_for_ventilation_system_off": 0.004,
|
||||
"constructions": {
|
||||
"OutdoorsWall": {
|
||||
"opaque_surface_name": "hotel_employees_1981_2010_BWh",
|
||||
|
|
File diff suppressed because it is too large
Load Diff
|
@ -21,6 +21,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -44,6 +46,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -67,6 +71,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -89,6 +95,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -111,6 +119,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -133,6 +143,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -155,6 +167,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -177,6 +191,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -199,6 +215,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -221,6 +239,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -243,6 +263,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -265,6 +287,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -287,6 +311,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -309,6 +335,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -331,6 +359,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -353,6 +383,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -375,6 +407,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -397,6 +431,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -419,6 +455,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -441,6 +479,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -463,6 +503,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -485,6 +527,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -507,6 +551,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -529,6 +575,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -551,6 +599,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -573,6 +623,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -595,6 +647,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -617,6 +671,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -639,6 +695,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -661,6 +719,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -683,6 +743,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -705,6 +767,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -727,6 +791,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -749,6 +815,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="35" building_type="residential" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -771,6 +839,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="36" building_type="residential" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -793,6 +863,8 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
<archetype id="37" building_type="industry" reference_standard="non_standard_dompark" climate_zone="ASHRAE_2004:4A">
|
||||
<constructions>
|
||||
|
@ -815,5 +887,7 @@
|
|||
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
|
||||
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
|
||||
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
|
||||
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
|
||||
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
|
||||
</archetype>
|
||||
</archetypes>
|
||||
|
|
|
@ -392,9 +392,9 @@ class Idf:
|
|||
thermostat = self._add_thermostat(thermal_zone)
|
||||
self._idf.newidfobject(self._IDEAL_LOAD_AIR_SYSTEM,
|
||||
Zone_Name=zone_name,
|
||||
System_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
||||
Heating_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
||||
Cooling_Availability_Schedule_Name=f'HVAC AVAIL SCHEDULES {thermal_zone.usage_name}',
|
||||
System_Availability_Schedule_Name=f'Thermostat_availability schedules {thermal_zone.usage_name}',
|
||||
Heating_Availability_Schedule_Name=f'Thermostat_availability schedules {thermal_zone.usage_name}',
|
||||
Cooling_Availability_Schedule_Name=f'Thermostat_availability schedules {thermal_zone.usage_name}',
|
||||
Template_Thermostat_Name=thermostat.Name)
|
||||
|
||||
def _add_occupancy(self, thermal_zone, zone_name):
|
||||
|
@ -454,7 +454,7 @@ class Idf:
|
|||
)
|
||||
|
||||
def _add_infiltration(self, thermal_zone, zone_name):
|
||||
schedule = f'Infiltration schedules {thermal_zone.usage_name}'
|
||||
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
|
||||
_infiltration = thermal_zone.infiltration_rate_system_off * cte.HOUR_TO_SECONDS
|
||||
self._idf.newidfobject(self._INFILTRATION,
|
||||
Name=f'{zone_name}_infiltration',
|
||||
|
@ -464,6 +464,17 @@ class Idf:
|
|||
Air_Changes_per_Hour=_infiltration
|
||||
)
|
||||
|
||||
def _add_infiltration_surface(self, thermal_zone, zone_name):
|
||||
schedule = f'INF_CONST schedules {thermal_zone.usage_name}'
|
||||
_infiltration = thermal_zone.infiltration_rate_area_system_off*cte.INFILTRATION_75PA_TO_4PA
|
||||
self._idf.newidfobject(self._INFILTRATION,
|
||||
Name=f'{zone_name}_infiltration',
|
||||
Zone_or_ZoneList_or_Space_or_SpaceList_Name=zone_name,
|
||||
Schedule_Name=schedule,
|
||||
Design_Flow_Rate_Calculation_Method='Flow/ExteriorWallArea',
|
||||
Flow_Rate_per_Exterior_Surface_Area=_infiltration
|
||||
)
|
||||
|
||||
def _add_ventilation(self, thermal_zone, zone_name):
|
||||
schedule = f'Ventilation schedules {thermal_zone.usage_name}'
|
||||
_air_change = thermal_zone.mechanical_air_change * cte.HOUR_TO_SECONDS
|
||||
|
@ -549,9 +560,12 @@ class Idf:
|
|||
self._add_schedules(usage, 'DHW_prof', thermal_zone.domestic_hot_water.schedules)
|
||||
_new_schedules = self._create_yearly_values_schedules('cold_temp', building.cold_water_temperature[cte.HOUR])
|
||||
self._add_schedules(usage, 'cold_temp', _new_schedules)
|
||||
|
||||
_new_schedules = self._create_constant_value_schedules('DHW_temp', service_temperature)
|
||||
self._add_schedules(usage, 'DHW_temp', _new_schedules)
|
||||
_new_schedules = self._create_constant_value_schedules('INF_CONST', 1)
|
||||
self._add_schedules(usage, 'INF_CONST', _new_schedules)
|
||||
_new_schedules = self._create_constant_value_schedules('Thermostat_availability', 1)
|
||||
self._add_schedules(usage, 'Thermostat_availability', _new_schedules)
|
||||
_occ = thermal_zone.occupancy
|
||||
if _occ.occupancy_density == 0:
|
||||
_total_heat = 0
|
||||
|
@ -562,7 +576,7 @@ class Idf:
|
|||
self._add_schedules(usage, 'Activity Level', _new_schedules)
|
||||
self._add_zone(thermal_zone, building.name)
|
||||
self._add_heating_system(thermal_zone, building.name)
|
||||
self._add_infiltration(thermal_zone, building.name)
|
||||
self._add_infiltration_surface(thermal_zone, building.name)
|
||||
self._add_ventilation(thermal_zone, building.name)
|
||||
self._add_occupancy(thermal_zone, building.name)
|
||||
self._add_lighting(thermal_zone, building.name)
|
||||
|
@ -611,6 +625,18 @@ class Idf:
|
|||
Reporting_Frequency="Hourly",
|
||||
)
|
||||
|
||||
self._idf.newidfobject(
|
||||
"OUTPUT:VARIABLE",
|
||||
Variable_Name="Zone Air Temperature",
|
||||
Reporting_Frequency="Hourly",
|
||||
)
|
||||
|
||||
self._idf.newidfobject(
|
||||
"OUTPUT:VARIABLE",
|
||||
Variable_Name="Zone Air Relative Humidity",
|
||||
Reporting_Frequency="Hourly",
|
||||
)
|
||||
|
||||
# post-process to erase windows associated to adiabatic walls
|
||||
windows_list = []
|
||||
for window in self._idf.idfobjects[self._WINDOW]:
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
!IDD_Version 23.2.0
|
||||
!IDD_Version 24.1.0
|
||||
!IDD_BUILD 7636e6b3e9
|
||||
! ***************************************************************************
|
||||
! This file is the Input Data Dictionary (IDD) for EnergyPlus.
|
||||
|
@ -30002,10 +30002,10 @@ People,
|
|||
A7 , \field Mean Radiant Temperature Calculation Type
|
||||
\note optional (only required for thermal comfort runs)
|
||||
\type choice
|
||||
\key ZoneAveraged
|
||||
\key EnclosureAveraged
|
||||
\key SurfaceWeighted
|
||||
\key AngleFactor
|
||||
\default ZoneAveraged
|
||||
\default EnclosureAveraged
|
||||
A8 , \field Surface Name/Angle Factor List Name
|
||||
\type object-list
|
||||
\object-list AllHeatTranAngFacNames
|
||||
|
|
|
@ -13,7 +13,7 @@
|
|||
! HVAC: None.
|
||||
!
|
||||
|
||||
Version,23.2;
|
||||
Version,24.1;
|
||||
|
||||
Timestep,4;
|
||||
|
||||
|
@ -154,4 +154,4 @@
|
|||
Output:Meter,InteriorLights:Electricity,hourly;
|
||||
|
||||
OutputControl:IlluminanceMap:Style,
|
||||
Comma; !- Column separator
|
||||
Comma; !- Column separator
|
||||
|
|
|
@ -20,9 +20,10 @@ class EnergyBuildingsExportsFactory:
|
|||
"""
|
||||
Energy Buildings exports factory class
|
||||
"""
|
||||
def __init__(self, handler, city, path, custom_insel_block='d18599', target_buildings=None):
|
||||
def __init__(self, handler, city, path, custom_insel_block='d18599', target_buildings=None, weather_file=None):
|
||||
self._city = city
|
||||
self._export_type = '_' + handler.lower()
|
||||
self._weather_file = weather_file
|
||||
validate_import_export_type(EnergyBuildingsExportsFactory, handler)
|
||||
if isinstance(path, str):
|
||||
path = Path(path)
|
||||
|
@ -53,12 +54,13 @@ class EnergyBuildingsExportsFactory:
|
|||
"""
|
||||
idf_data_path = (Path(__file__).parent / './building_energy/idf_files/').resolve()
|
||||
url = wh().epw_file(self._city.region_code)
|
||||
weather_path = (Path(__file__).parent.parent / f'data/weather/epw/{url.rsplit("/", 1)[1]}').resolve()
|
||||
if not weather_path.exists():
|
||||
with open(weather_path, 'wb') as epw_file:
|
||||
if self._weather_file is None:
|
||||
self._weather_file = (Path(__file__).parent.parent / f'data/weather/epw/{url.rsplit("/", 1)[1]}').resolve()
|
||||
if not self._weather_file.exists():
|
||||
with open(self._weather_file, 'wb') as epw_file:
|
||||
epw_file.write(requests.get(url, allow_redirects=True).content)
|
||||
return Idf(self._city, self._path, (idf_data_path / 'Minimal.idf'), (idf_data_path / 'Energy+.idd'), weather_path,
|
||||
target_buildings=self._target_buildings)
|
||||
return Idf(self._city, self._path, (idf_data_path / 'Minimal.idf'), (idf_data_path / 'Energy+.idd'),
|
||||
self._weather_file, target_buildings=self._target_buildings)
|
||||
|
||||
@property
|
||||
def _insel_monthly_energy_balance(self):
|
||||
|
|
|
@ -24,6 +24,8 @@ BTU_H_TO_WATTS = 0.29307107
|
|||
KILO_WATTS_HOUR_TO_JULES = 3600000
|
||||
WATTS_HOUR_TO_JULES = 3600
|
||||
GALLONS_TO_QUBIC_METERS = 0.0037854117954011185
|
||||
INFILTRATION_75PA_TO_4PA = (4/75)**0.65
|
||||
|
||||
|
||||
# time
|
||||
SECOND = 'second'
|
||||
|
|
|
@ -66,6 +66,8 @@ class EilatPhysicsParameters:
|
|||
thermal_archetype.indirect_heated_ratio = 0
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||
effective_thermal_capacity = 0
|
||||
_constructions = []
|
||||
for catalog_construction in catalog_archetype.constructions:
|
||||
|
|
|
@ -78,6 +78,9 @@ class NrcanPhysicsParameters:
|
|||
thermal_archetype.indirect_heated_ratio = 0
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||
|
||||
_constructions = []
|
||||
for catalog_construction in catalog_archetype.constructions:
|
||||
construction = Construction()
|
||||
|
|
|
@ -69,6 +69,8 @@ class NrelPhysicsParameters:
|
|||
thermal_archetype.indirect_heated_ratio = catalog_archetype.indirect_heated_ratio
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
|
||||
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
|
||||
_constructions = []
|
||||
for catalog_construction in catalog_archetype.constructions:
|
||||
construction = Construction()
|
||||
|
|
|
@ -136,3 +136,7 @@ class City(Repository):
|
|||
except SQLAlchemyError as err:
|
||||
logging.error('Error while fetching city by name %s', err)
|
||||
raise SQLAlchemyError from err
|
||||
|
||||
def get_by_id(self, city_id) -> Model:
|
||||
with Session(self.engine) as session:
|
||||
return session.execute(select(Model).where(Model.id == city_id)).first()[0]
|
Loading…
Reference in New Issue
Block a user