Compare commits

..

9 Commits

10 changed files with 120 additions and 160 deletions

View File

@ -22,6 +22,7 @@ class EilatCatalog(Catalog):
"""
Eilat catalog class
"""
def __init__(self, path):
_path_archetypes = Path(path / 'eilat_archetypes.json').resolve()
_path_constructions = (path / 'eilat_constructions.json').resolve()
@ -121,8 +122,14 @@ class EilatCatalog(Catalog):
construction_period = archetype['period_of_construction']
average_storey_height = archetype['average_storey_height']
extra_loses_due_to_thermal_bridges = archetype['extra_loses_due_thermal_bridges']
infiltration_rate_for_ventilation_system_off = archetype['infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_on = archetype['infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_off = archetype[
'infiltration_rate_for_ventilation_system_off'] / cte.HOUR_TO_SECONDS
infiltration_rate_for_ventilation_system_on = archetype[
'infiltration_rate_for_ventilation_system_on'] / cte.HOUR_TO_SECONDS
infiltration_rate_area_for_ventilation_system_off = archetype[
'infiltration_rate_area_for_ventilation_system_off']
infiltration_rate_area_for_ventilation_system_on = archetype[
'infiltration_rate_area_for_ventilation_system_on']
archetype_constructions = []
for archetype_construction in archetype['constructions']:
@ -160,7 +167,9 @@ class EilatCatalog(Catalog):
extra_loses_due_to_thermal_bridges,
None,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on))
infiltration_rate_for_ventilation_system_on,
infiltration_rate_area_for_ventilation_system_off,
infiltration_rate_area_for_ventilation_system_on))
return _catalog_archetypes
def names(self, category=None):

View File

@ -129,6 +129,12 @@ class NrelCatalog(Catalog):
infiltration_rate_for_ventilation_system_on = float(
archetype['infiltration_rate_for_ventilation_system_on']['#text']
) / cte.HOUR_TO_SECONDS
infiltration_rate_area_for_ventilation_system_off = float(
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
)
infiltration_rate_area_for_ventilation_system_on = float(
archetype['infiltration_rate_area_for_ventilation_system_on']['#text']
)
archetype_constructions = []
for archetype_construction in archetype['constructions']['construction']:
@ -162,7 +168,9 @@ class NrelCatalog(Catalog):
extra_loses_due_to_thermal_bridges,
indirect_heated_ratio,
infiltration_rate_for_ventilation_system_off,
infiltration_rate_for_ventilation_system_on))
infiltration_rate_for_ventilation_system_on,
infiltration_rate_area_for_ventilation_system_off,
infiltration_rate_area_for_ventilation_system_on))
return _catalog_archetypes
def names(self, category=None):

View File

@ -20,8 +20,8 @@ class ThermalArchetype:
self._indirect_heated_ratio = None
self._infiltration_rate_for_ventilation_system_off = None
self._infiltration_rate_for_ventilation_system_on = None
self._infiltration_rate_area_for_ventilation_system_off=None
self._infiltration_rate_area_for_ventilation_system_on=None
self._infiltration_rate_area_for_ventilation_system_off = None
self._infiltration_rate_area_for_ventilation_system_on = None
@property
def constructions(self) -> [Construction]:
@ -141,7 +141,7 @@ class ThermalArchetype:
Get infiltration rate for ventilation system off in l/s/m2
:return: float
"""
return self._infiltration_rate_for_ventilation_system_off
return self._infiltration_rate_area_for_ventilation_system_off
@infiltration_rate_area_for_ventilation_system_off.setter
def infiltration_rate_area_for_ventilation_system_off(self, value):
@ -149,7 +149,7 @@ class ThermalArchetype:
Set infiltration rate for ventilation system off in l/s/m2
:param value: float
"""
self._infiltration_rate_for_ventilation_system_off = value
self._infiltration_rate_area_for_ventilation_system_off = value
@property
def infiltration_rate_area_for_ventilation_system_on(self):
@ -157,7 +157,7 @@ class ThermalArchetype:
Get infiltration rate for ventilation system on in l/s/m2
:return: float
"""
return self._infiltration_rate_for_ventilation_system_on
return self._infiltration_rate_area_for_ventilation_system_on
@infiltration_rate_area_for_ventilation_system_on.setter
def infiltration_rate_area_for_ventilation_system_on(self, value):
@ -165,4 +165,4 @@ class ThermalArchetype:
Set infiltration rate for ventilation system on in l/s/m2
:param value: float
"""
self._infiltration_rate_for_ventilation_system_on = value
self._infiltration_rate_area_for_ventilation_system_on = value

View File

@ -8,6 +8,8 @@
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.9,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.006,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "residential_1000_1980_BWh",
@ -42,6 +44,8 @@
"extra_loses_due_thermal_bridges": 0.1,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.31,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.002,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "dormitory_2011_3000_BWh",
@ -76,6 +80,8 @@
"extra_loses_due_thermal_bridges": 0.09,
"infiltration_rate_for_ventilation_system_on": 0,
"infiltration_rate_for_ventilation_system_off": 0.65,
"infiltration_rate_area_for_ventilation_system_on": 0,
"infiltration_rate_area_for_ventilation_system_off": 0.004,
"constructions": {
"OutdoorsWall": {
"opaque_surface_name": "hotel_employees_1981_2010_BWh",

View File

@ -21,6 +21,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.5</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="2" building_type="medium office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -44,6 +46,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="3" building_type="large office" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -67,6 +71,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="4" building_type="primary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -89,6 +95,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="5" building_type="secondary school" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -111,6 +119,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="6" building_type="stand-alone retail" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -133,6 +143,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="7" building_type="strip mall" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -155,6 +167,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="8" building_type="supermarket" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -177,6 +191,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="9" building_type="quick service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -199,6 +215,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="10" building_type="full service restaurant" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -221,6 +239,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="11" building_type="small hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -243,6 +263,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="12" building_type="large hotel" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -265,6 +287,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="13" building_type="hospital" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -287,6 +311,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="14" building_type="outpatient healthcare" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -309,6 +335,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="15" building_type="warehouse" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -331,6 +359,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="16" building_type="midrise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -353,6 +383,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="17" building_type="high-rise apartment" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -375,6 +407,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="18" building_type="small office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -397,6 +431,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="19" building_type="medium office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -419,6 +455,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="20" building_type="large office" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -441,6 +479,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="21" building_type="primary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -463,6 +503,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="22" building_type="secondary school" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -485,6 +527,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="23" building_type="stand-alone retail" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -507,6 +551,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="24" building_type="strip mall" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -529,6 +575,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.1</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="25" building_type="supermarket" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -551,6 +599,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="26" building_type="quick service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -573,6 +623,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="27" building_type="full service restaurant" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -595,6 +647,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="28" building_type="small hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -617,6 +671,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="29" building_type="large hotel" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -639,6 +695,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="30" building_type="hospital" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -661,6 +719,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="31" building_type="outpatient healthcare" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -683,6 +743,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="32" building_type="warehouse" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -705,6 +767,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="33" building_type="midrise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -727,6 +791,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="34" building_type="high-rise apartment" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -749,6 +815,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="35" building_type="residential" reference_standard="ASHRAE 189.1_2009" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -771,6 +839,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="36" building_type="residential" reference_standard="ASHRAE 90.1_2004" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -793,6 +863,8 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.50</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.003</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
<archetype id="37" building_type="industry" reference_standard="non_standard_dompark" climate_zone="ASHRAE_2004:4A">
<constructions>
@ -815,5 +887,7 @@
<indirect_heated_ratio units="-">0.15</indirect_heated_ratio>
<infiltration_rate_for_ventilation_system_off units="ACH">0.10</infiltration_rate_for_ventilation_system_off>
<infiltration_rate_for_ventilation_system_on units="ACH">0</infiltration_rate_for_ventilation_system_on>
<infiltration_rate_area_for_ventilation_system_off units="ACH">0.0005</infiltration_rate_area_for_ventilation_system_off>
<infiltration_rate_area_for_ventilation_system_on units="ACH">0</infiltration_rate_area_for_ventilation_system_on>
</archetype>
</archetypes>

View File

@ -66,6 +66,8 @@ class EilatPhysicsParameters:
thermal_archetype.indirect_heated_ratio = 0
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
effective_thermal_capacity = 0
_constructions = []
for catalog_construction in catalog_archetype.constructions:

View File

@ -69,6 +69,8 @@ class NrelPhysicsParameters:
thermal_archetype.indirect_heated_ratio = catalog_archetype.indirect_heated_ratio
thermal_archetype.infiltration_rate_for_ventilation_system_on = catalog_archetype.infiltration_rate_for_ventilation_system_on
thermal_archetype.infiltration_rate_for_ventilation_system_off = catalog_archetype.infiltration_rate_for_ventilation_system_off
thermal_archetype.infiltration_rate_area_for_ventilation_system_on = catalog_archetype.infiltration_rate_area_for_ventilation_system_on
thermal_archetype.infiltration_rate_area_for_ventilation_system_off = catalog_archetype.infiltration_rate_area_for_ventilation_system_off
_constructions = []
for catalog_construction in catalog_archetype.constructions:
construction = Construction()

View File

@ -24,7 +24,7 @@ class EnergyPlusMultipleBuildings:
csv_output = list(csv.DictReader(csv_file))
for building in self._city.buildings:
building_name = building.name
building_name = building.name.upper()
buildings_energy_demands[f'Building {building_name} Heating Demand (J)'] = [
float(
row[f"{building_name} IDEAL LOADS AIR SYSTEM:Zone Ideal Loads Supply Air Total Heating Energy [J](Hourly)"])
@ -36,7 +36,7 @@ class EnergyPlusMultipleBuildings:
for row in csv_output
]
buildings_energy_demands[f'Building {building_name} DHW Demand (W)'] = [
float(row[f"DHW {building.name}:Water Use Equipment Heating Rate [W](Hourly)"])
float(row[f"DHW {building_name}:Water Use Equipment Heating Rate [W](Hourly)"])
for row in csv_output
]
buildings_energy_demands[f'Building {building_name} Appliances (W)'] = [
@ -58,14 +58,15 @@ class EnergyPlusMultipleBuildings:
if energy_plus_output_file_path.is_file():
building_energy_demands = self._building_energy_demands(energy_plus_output_file_path)
for building in self._city.buildings:
building.heating_demand[cte.HOUR] = building_energy_demands[f'Building {building.name} Heating Demand (J)']
building.cooling_demand[cte.HOUR] = building_energy_demands[f'Building {building.name} Cooling Demand (J)']
building_name = building.name.upper()
building.heating_demand[cte.HOUR] = building_energy_demands[f'Building {building_name} Heating Demand (J)']
building.cooling_demand[cte.HOUR] = building_energy_demands[f'Building {building_name} Cooling Demand (J)']
building.domestic_hot_water_heat_demand[cte.HOUR] = \
[x * cte.WATTS_HOUR_TO_JULES for x in building_energy_demands[f'Building {building.name} DHW Demand (W)']]
[x * cte.WATTS_HOUR_TO_JULES for x in building_energy_demands[f'Building {building_name} DHW Demand (W)']]
building.appliances_electrical_demand[cte.HOUR] = \
[x * cte.WATTS_HOUR_TO_JULES for x in building_energy_demands[f'Building {building.name} Appliances (W)']]
[x * cte.WATTS_HOUR_TO_JULES for x in building_energy_demands[f'Building {building_name} Appliances (W)']]
building.lighting_electrical_demand[cte.HOUR] = \
[x * cte.WATTS_HOUR_TO_JULES for x in building_energy_demands[f'Building {building.name} Lighting (W)']]
[x * cte.WATTS_HOUR_TO_JULES for x in building_energy_demands[f'Building {building_name} Lighting (W)']]
building.heating_demand[cte.MONTH] = MonthlyValues.get_total_month(building.heating_demand[cte.HOUR])
building.cooling_demand[cte.MONTH] = MonthlyValues.get_total_month(building.cooling_demand[cte.HOUR])
building.domestic_hot_water_heat_demand[cte.MONTH] = (

View File

@ -10,7 +10,7 @@ with pathlib.Path('requirements.txt').open() as r:
for requirement
in r.readlines()
]
install_requires.append('setuptools')
install_requires.append('setuptools, build')
main_ns = {}
version = convert_path('hub/version.py')

142
texttest
View File

@ -1,142 +0,0 @@
ZoneControl:Thermostat,
Room_180_7ad8616b Thermostat, !- Name
Room_180_7ad8616b, !- Zone or ZoneList Name
Room_180_7ad8616b Thermostat Schedule, !- Control Type Schedule Name
ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
LargeOffice Building_Setpoint 26, !- Control 1 Name
, !- Control 2 Object Type
, !- Control 2 Name
, !- Control 3 Object Type
, !- Control 3 Name
, !- Control 4 Object Type
, !- Control 4 Name
0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
Schedule:Compact,
Room_180_7ad8616b Thermostat Schedule, !- Name
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Schedule Type Limits Name
Through: 12/31, !- Field 1
For: AllDays, !- Field 2
Until: 24:00, !- Field 3
4; !- Field 4
ScheduleTypeLimits,
Room_180_7ad8616b Thermostat Schedule Type Limits, !- Name
0, !- Lower Limit Value {BasedOnField A3}
4, !- Upper Limit Value {BasedOnField A3}
DISCRETE; !- Numeric Type
ThermostatSetpoint:DualSetpoint,
LargeOffice Building_Setpoint 26, !- Name
LargeOffice Building_Setpoint_HtgSetp Schedule, !- Heating Setpoint Temperature Schedule Name
LargeOffice Building_Setpoint_ClgSetp Schedule; !- Cooling Setpoint Temperature Schedule Name
ZoneHVAC:EquipmentConnections,
Room_180_7ad8616b, !- Zone Name
Room_180_7ad8616b Equipment List, !- Zone Conditioning Equipment List Name
Room_180_7ad8616b Inlet Node List, !- Zone Air Inlet Node or NodeList Name
, !- Zone Air Exhaust Node or NodeList Name
Node 27, !- Zone Air Node Name
Room_180_7ad8616b Return Node List; !- Zone Return Air Node or NodeList Name
NodeList,
Room_180_7ad8616b Inlet Node List, !- Name
Node 305; !- Node Name 1
NodeList,
Room_180_7ad8616b Return Node List, !- Name
Node 308; !- Node Name 1
ZoneHVAC:Baseboard:Convective:Electric,
Elec Baseboard 1, !- Name
Always On Discrete hvac_library, !- Availability Schedule Name
, !- Heating Design Capacity Method
Autosize, !- Heating Design Capacity {W}
, !- Heating Design Capacity Per Floor Area {W/m2}
, !- Fraction of Autosized Heating Design Capacity
1; !- Efficiency
AirTerminal:SingleDuct:ConstantVolume:NoReheat,
Diffuser 21, !- Name
Always On Discrete hvac_library, !- Availability Schedule Name
Node 307, !- Air Inlet Node Name
Node 305, !- Air Outlet Node Name
AutoSize; !- Maximum Air Flow Rate {m3/s}
ZoneHVAC:AirDistributionUnit,
ADU Diffuser 21, !- Name
Node 305, !- Air Distribution Unit Outlet Node Name
AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type
Diffuser 21; !- Air Terminal Name
ZoneHVAC:EquipmentList,
Room_180_7ad8616b Equipment List, !- Name
SequentialLoad, !- Load Distribution Scheme
ZoneHVAC:Baseboard:Convective:Electric, !- Zone Equipment Object Type 1
Elec Baseboard 1, !- Zone Equipment Name 1
1, !- Zone Equipment Cooling Sequence 1
1, !- Zone Equipment Heating or No-Load Sequence 1
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 1
, !- Zone Equipment Sequential Heating Fraction Schedule Name 1
ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type 2
ADU Diffuser 21, !- Zone Equipment Name 2
2, !- Zone Equipment Cooling Sequence 2
2, !- Zone Equipment Heating or No-Load Sequence 2
, !- Zone Equipment Sequential Cooling Fraction Schedule Name 2
; !- Zone Equipment Sequential Heating Fraction Schedule Name 2
Sizing:Zone,
Room_180_7ad8616b, !- Zone or ZoneList Name
SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
14, !- Zone Cooling Design Supply Air Temperature {C}
11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
40, !- Zone Heating Design Supply Air Temperature {C}
11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
Room_180_7ad8616b DSOA Space List, !- Design Specification Outdoor Air Object Name
, !- Zone Heating Sizing Factor
, !- Zone Cooling Sizing Factor
DesignDay, !- Cooling Design Air Flow Method
0, !- Cooling Design Air Flow Rate {m3/s}
0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
0, !- Cooling Minimum Air Flow {m3/s}
0, !- Cooling Minimum Air Flow Fraction
DesignDay, !- Heating Design Air Flow Method
0, !- Heating Design Air Flow Rate {m3/s}
0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
0.1415762, !- Heating Maximum Air Flow {m3/s}
0.3, !- Heating Maximum Air Flow Fraction
, !- Design Specification Zone Air Distribution Object Name
No, !- Account for Dedicated Outdoor Air System
, !- Dedicated Outdoor Air System Control Strategy
, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C}
, !- Dedicated Outdoor Air High Setpoint Temperature for Design {C}
Sensible Load Only No Latent Load, !- Zone Load Sizing Method
HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method
, !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method
, !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
DesignSpecification:OutdoorAir:SpaceList,
Room_180_7ad8616b DSOA Space List, !- Name
Room_180_7ad8616b_Space, !- Space Name 1
MidriseApartment Apartment Ventilation; !- Space Design Specification Outdoor Air Object Name 1
Zone,
Room_181_3a411b5d, !- Name
, !- Direction of Relative North {deg}
0, !- X Origin {m}
0, !- Y Origin {m}
0, !- Z Origin {m}
, !- Type
1, !- Multiplier
4, !- Ceiling Height {m}
291.62935408288, !- Volume {m3}
, !- Floor Area {m2}
, !- Zone Inside Convection Algorithm
, !- Zone Outside Convection Algorithm
Yes; !- Part of Total Floor Area